Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

EMD8216/A Ethernet Digital I/O module User's Manual (V1.5) 健昇科技股份有限公司 JS AUTOMATION CORP. 新北市汐止區中興路 100 號 6 樓 6F., No.100, Zhongxing Rd., Xizhi Dist., New Taipei City, Taiwan TEL:+886-2-2647-6936 FAX:+886-2-2647-6940 http://www.automation.com.tw http://www.automation-js.com/ E-mail:[email protected] Correction record Version Record 1.0 firmware version 1.0 up 1.1 Add System Reset 1.2 1. Modify 3.4.5 dimension 2. Add 1.3 4.2 dimension Image Update 6.1 I/O diagram 1.4 1. Add EMD8216A Information 1.5 2. Modify Notes on hardware installation 3. Add Warranty 4. Add specifications to each input and output (chapt. 6) 5. Modify Ordering information 1 Contents 1. 2. 3. 4. 5. 6. 7. 8. 9. Forward ................................................................................................................................................ 5 Features ................................................................................................................................................ 6 Specifications ....................................................................................................................................... 7 3.1 Digital input ................................................................................................................................ 7 3.2 Digital output .............................................................................................................................. 7 3.3 Ethernet ....................................................................................................................................... 7 3.4 General ........................................................................................................................................ 7 Layout and dimensions ........................................................................................................................ 8 4.1 EMD8216/A Layout .................................................................................................................... 8 4.2 EMD8216/A Dimension ............................................................................................................. 8 Pin definitions ...................................................................................................................................... 9 5.1 JM1 pin definitions ..................................................................................................................... 9 5.2 JM2 pin definitions ..................................................................................................................... 9 5.3 JM3 pin definitions ..................................................................................................................... 9 5.4 JM4 pin definitions ..................................................................................................................... 9 I/O Interface diagram ......................................................................................................................... 10 6.1 I/O diagram ............................................................................................................................... 10 System Reset ...................................................................................................................................... 11 7.1 Normal system reset .................................................................................................................. 11 7.2 Reset to default.......................................................................................................................... 11 Applications ....................................................................................................................................... 12 Ordering information ......................................................................................................................... 13 2 Notes on hardware installation For more detail of step by step installation guide, please refer the file “..\download\Supplemental_technical_data\Ethernet-IO_module_EMD.pdf “ on the CD come with the product or download the document from http://www.automation.com.tw/common/Supplemental_technical_data.htm 3 Warranty The EMD8216/A are warranted against defects in materials and workmanship for a period of two years from the date of shipment, as evidenced by receipts or serial no. on board. JS automation Corp. will, at its option, repair or replace product that proves to be defective during the warranty period. This warranty includes parts, labor and shipping costs of returning. Except as specified herein, JS automation Corp. makes no warranties, express or implied, and specifically disclaims any warranty of merchantability or fitness for a particular purpose. Customer’s right to recover damages caused by fault or negligence on the part of JS automation Corp. shall be limited to the amount theretofore paid by the customer. JS automation Corp. will not be liable for damages resulting from loss of data, profits, use of products, or incidental or consequential damages, even if advised of the possibility thereof. This limitation of the liability of JS automation Corp. will apply regardless of the form of action, whether in contract or tort, including negligence. Any action against JS automation Corp. must be brought within one year after the cause of action accrues. JS automation Corp. shall not be liable for any delay in performance due to causes beyond its reasonable control. The warranty provided herein does not cover damages, defects, malfunctions, or service failures caused by owner’s failure to follow the JS automation Corp. installation, operation, or maintenance instructions; owner’s modification of the product; owner’s abuse, misuse, or negligent acts; and power failure or surges, fire, flood, accident, actions of third parties, or other events outside reasonable control. If any defect occurs, you should email to us as the following form to get the fast response: Detailed Company Information Company/Organization: Contact Person: E-mail: Address: Country: Tel/Fax: Web Site: Product information product model: serial no.: Environment to Use: such as CPU board, Operating System, target application... description of defect: (as detail as possible) 4 1. Forward Thank you for your selection of Ethernet module 8216 digital input output interface. Thanks to the booming of network, Ethernet become a reliable and low cost solution for data communication. To utilize the Ethernet as data communication highway of industrial control devices is more attractive than ever. We also provide the dll’s of Window’s or Linux system, enabling you coding the flexible application as you need. Stable, high reliability and remote addressable module give you a new approach of application. In the same series: EMD8204 4 Isolated input and 4 relay output Ethernet DIO module EMD8208 8 Isolated input and 8 relay output Ethernet DIO module Any comment is welcome, please visit our website http://www.automation.com.tw/ http://www.automation-js.com/ for the up to date information. 5 2. Features - Over-voltage protection on digital input - Various IO combinations : 16 bit configurable I/O’s, any bit can be input or output - High drive capacity on digital output - Digital I/P as counter input - WDT for communication discontinuity detect - Wide power range - Standalone mode:step sequence control - IP re-assignment - 10/100M auto detection - Software key function - Peer to peer response time <2ms 6 3. Specifications 3.1 Digital input 3.1.1 Input points: max 16 (Configurable) 3.1.2 Logic high level: 3.15V(min) 3.1.3 Logic low level: 1.35V(max) 3.1.4 Over-voltage protection: 60Vdc(max) 3.1.5 Over-current protection: 50mA(max) 3.2 Digital output 3.2.1 3.2.2 Transistor output: max 16 (Configurable) Transistor capacity: 50mA, 45Vdc(max) 3.3 Ethernet 3.3.1 10/100M auto switch x 2 port 3.3.2 Peer to peer response time <2ms 3.3.3 WDT : 1~65535ms for communication discontinuity detect 3.4 General 3.4.1 Power requirement: 12Vdc ~24Vdc 3.4.2 3.4.3 3.4.4 3.4.5 Operation Temperature: 0 ~ +70 degree C Storage Temperature: -20 ~ +80 degree C Operation Humidity: 5~95% RH, non-condensing Dimension: 115.4(D)*136(W)*34(H) mm 4.6(D)*5.4(W)*1.4(H) in 7 4. Layout and dimensions 4.1 EMD8216/A Layout LED1: system active LED J2,J3: Ethernet RJ45 socket JM1, JM2, JM3, JM4: I/O connector JM5: external power 24V connector SW2: system reset switch 4.2 EMD8216/A Dimension 8 5. Pin definitions 5.1 JM1 pin definitions +Ve0* 1 IO_00 2 IO_01 3 IO_02 4 IO_03 5 GND 6 5.2 JM2 pin definitions IO_04 1 IO_05 2 IO_06 3 IO_07 4 GND 5 5.3 JM3 pin definitions +Ve1* 1 IO_10 2 IO_11 3 IO_12 4 IO_13 5 GND 6 5.4 JM4 pin definitions IO_14 1 IO_15 2 IO_16 3 IO_17 4 GND 5 * +Ve0 and +Ve1 can floating or voltage input (voltage range +3.3V ~ +24V) * +Ve0 is used for IO_00~IO_07, +Ve1 is used for IO_10~IO_17. * +Ve0 and +Ve1 can apply different voltage as you need. 9 6. I/O Interface diagram 6.1 I/O diagram For IO_00 ~ IO_07, IO_10 ~ IO_17 I/P specification: +Ve ** +Ve ** (max) 24V +Ve ** (min) N/A VI ** VIH** (min) 3.15V VIL ** (max) 1.35V II ** II ** (max) 50mA For IO_00 ~ IO_07, IO_10 ~ IO_17 O/P specification: +Ve ** +Ve ** (max) 24V +Ve ** (min) N/A VO ** VO** (min) 0V VO ** (max) +Ve IO ** IO ** (max) Note: 50mA +Ve0 requied externally applied +24V then the IO_00 ~ IO07 will be also applied. Same to +Ve1 for IO_10~IO_17 ** VI, input voltage ** VIH, High-level input voltage ** VIL, Low-level input voltage ** II, input current ** VO, output voltage ** IO, output current ** +Ve, External voltage 10 7. System Reset The system reset switch SW2 has provide normal system reset and reset to default functions. 7.1 Normal system reset Push the SW2 for more than 5 seconds, the power LED will flick at 3 HZ to signal the system has already reset. Once you release the switch, the LED will return to normal flick rate. 7.2 Reset to default Push the switch while power on (We suggest to push the switch first then power on and wait for 3 seconds) for 3 seconds, the LED will: 1. stop flick 2. flicking at 3 Hz--- system now setting default data 3. flicking at normal speed --- system now already reset, you can release the switch. item default value IP 192.168.0.100 password 12345678 socket port 6936 IO_config ALL input (0xFF) polarity ALL inactive (0x0) WDT timer 1second (0xA) WDT output state ALL inactive (0x0) Standalone function ALL clean (0x0) Power on standalone Disable (0x0) 11 8. Applications  For remote contact sensing -- window or door open/close signal sensing -- alram signal sensing -- fire detector signal sensing  For remote contact make or break control -- window or door open close control -- light control -- power on/off control   Standalone step sequence controller Multi-channel low speed counter (100Hz) 12 9. Ordering information PRODUCT DESCRIPTIONS EMD8216 Ethernet module, 16 I/O EMD8216A Ethernet module, 16 I/O for Artcon JD52038 110/220Vac to 24Vdc @1.5A power supply JS52026 110/220Vac to 24Vdc @0.75A power adapter 13