Arena Symphony AS149DPC / 96549619 ARENA S T16 1X49 HFI WL6 EDP PC 850 Times New Roman G5
49W T16
Arena Symphony A suspended architectural raft incorporating direct/indirect luminaire design. 1 x 49W T16 lamp(s). Electronic, DALI / DSI digital dimmable control gear. Body: steel, white (close to RAL 9010). diffuser: reeded curved polycarbonate. Electrical connection via 6 pole Wieland connector. Lamps to be ordered separately. Dimensions: 2200 x 850 x 135 mm Total power: 53 W Weight: 23 kg Luminaire efficacy: 72 lm/W
TLG_ARNS_F_CURVEDDIF.jpg
180° 150°
150°
120°
90°
120°
300
200
100
90°
60°
60°
30° cd/klm
30° 0° TLG_SP_0040663.ldt
Lamp position: STD - standard Lamps: 1 x T16 / 49W Total luminous flux: 4300 lm Luminaire efficacy: 72 lm/W Colour Rendering Index min.: 80 Lamp efficacy: 81 lm/W
Ballast: 1x HFI* Tridonic PCA T5 ECO lp Connected Load: 53 W Lambda = 0.97 Standby Power: 0.2 W Dimming: DALIDSI dimmable to 1% CELMA EEI: A1 BAT LOR: 0,89 ULOR: 0,23 DLOR: 0,66
Thorn Lighting is constantly developing and improving its products. The right is reserved to change specifications without prior notification or public announcement. © Thorn Lighting
Arena Symphony AS149DPC / 96549619 ARENA S T16 1X49 HFI WL6 EDP PC 850 Times New Roman
180° 150°
150°
120°
90°
0° 5° 10° 15° 20° 25° 30° 35° 40° 45° 50° 55° 60° 65° 70° 75° 80° 85° 90° 95° 100° 105° 110° 115° 120° 125° 130° 135° 140° 145° 150° 155° 160° 165° 170° 175° 180°
120°
300
200
100
90°
60°
60°
30°
30°
cd/klm
C180 | C0 C270 | C90
0°
Light output ratio
Glare Evaluation
C0 174 172 193 227 243 248 250 242 209 174 161 137 98 68 49 40 38 37 33 2 2 2 2 4 6 8 10 18 33 49 66 84 105 121 129 130 129
C90 C180 C270 174 174 174 172 172 172 171 193 171 171 227 171 169 243 169 166 248 166 160 250 160 150 242 150 136 209 136 118 174 118 99 161 99 76 137 76 53 98 53 34 68 34 20 49 20 12 40 12 7 38 7 4 37 4 2 33 2 4 2 4 12 2 12 22 2 22 33 2 33 44 4 44 55 6 55 66 8 66 76 10 76 85 18 85 95 33 95 103 49 103 111 66 111 117 84 117 122 105 122 125 121 125 127 129 127 129 130 129 129 129 129
Classification
LOR
89 %
X= 4 H, Y= 8 H
ULOR
23 %
Reflection factors
70/50/20
EN
55°<3000cd/m² 65°<3000cd/m²
DLOR
66 %
UGR transversal
<19
BZ
BZ4/5/BZ5
UGR axial
<16
UTE
0.66 D + 0.23 T
CIE Flux Codes
48 79 93 74 89
FFR
0.35 (26:74)
BLF
1.00
S = 1.00 H
LiTG
B43
Utilization Factors Room Reflectance Ceiling/Walls/Floor
0.75
1.00
1.25
1.50
Room Index 2.00
2.50
3.00
4.00
5.00
70 / 50 / 20
NA
57
62
66
72
76
78
82
84
70 / 30 / 20
NA
51
56
61
67
71
74
78
81
70 / 10 / 20
NA
46
52
56
63
67
71
75
78
50 / 50 / 20
NA
52
57
61
66
69
71
74
76
50 / 30 / 20
NA
47
52
56
62
65
68
72
74
50 / 10 / 20
NA
44
49
53
58
62
65
69
72
30 / 50 / 20
NA
48
53
56
60
63
65
67
69
30 / 30 / 20
NA
44
49
52
57
60
62
65
67
30 / 10 / 20
NA
41
46
49
54
58
60
64
66
0/ 0/ 0
NA
37
41
44
48
50
52
55
57
According to CIBSE Technical Memorandum No. 5 1980
SHR Nom = SHR Max = SHR Max TR =
1.75 1.98 2.42
Photometric data file: TLG_SP_0040663.ldt
Thorn Lighting is constantly developing and improving its products. The right is reserved to change specifications without prior notification or public announcement. © Thorn Lighting