Transcript
MASTER LEDtube EM/ Mains MASTER LEDtube EM/ Mains MAS LEDtube 1200mm UO 18W 840 T8 RN
The Philips MASTER LEDtube integrates a LED light source into a traditional fluorescent form factor. Its unique design creates a perfectly uniform visual appearance which cannot be distinguished from traditional fluorescent. For those that are looking for value for money within limited budget and re-lamping efforts for better light effect and lifetime.
Product data • General Information Cap-Base Main Application Nominal Lifetime (Nom) Switching Cycle B50L70
G13 Industrial 50000 h 200000X 50000
• Light Technical Color Code Beam Angle (Nom) Luminous Flux (Nom) Luminous Flux (Rated) (Nom) Rated Beam Angle Correlated Color Temperature (Nom) Luminous Efficacy (rated) (Nom) Color Consistency Color Rendering Index (Nom) LLMF At End Of Nominal Lifetime (Nom)
840 [ CCT of 4000K (841)] 160 ° 2500 lm 2500 lm 160 ° 4000 K 139 lm/W <6 83 70 %
• Operating and Electrical Input Frequency Power (Rated) (Nom) Lamp Current (Max) Lamp Current (Min) Starting Time (Nom)
50 to 60 Hz 18 W 82 mA 75 mA 0.5 s
Warm Up Time To 60% Light (Nom) Power Factor (Nom) Voltage (Nom)
0.1 s 0.9 220-240 V
• Temperature T-Ambient (Max) T-Ambient (Min) T-Storage (Max) T-Storage (Min) T-Case Maximum (Nom)
35 °C -20 °C 65 °C -40 °C 55 °C
• Controls and Dimming Dimmable
No
• Mechanical and Housing Product Length
1200 mm
• Approval and Application Energy Saving Product Suitable For Accent Lighting Energy Efficiency Label (EEL) Approval Marks Energy Consumption kWh/1000 h
Yes No A++ CE marking KEMA Keur certificate RoHS compliance 18 kWh
MASTER LEDtube EM/Mains MASTER LEDtube EM/Mains • Product Data Full product code Order product name EAN/UPC - Product Order code
871869656529200 MAS LEDtube 1200mm UO 18W 840 T8 RN 8718696565292 929001222002
Numerator - Quantity Per Pack Numerator - Packs per outer box Material Nr. (12NC) Net Weight (Piece)
1 10 929001222002 0.270 kg
Warnings and Safety
Warnings and Safety
• NOTES: The overall energy efficiency and light distribution of any installation that uses these lamps are determined by the design of the installation.
• NOTES: The overall energy efficiency and light distribution of any installation that uses these lamps are determined by the design of the installation.
Dimensional drawing
A3
D1 D2
A2
TLED 4ft 220-240V 18W-36W 4000K G13 ND Product
D1
MAS LEDtube 1200mm UO 18W 840 T8 RN
25.78 mm 28 mm 588.6 mm 1205.3 mm 1212.4 mm
D2
A1
A2
A1
2016, August 8 data subject to change
A3
MASTER LEDtube EM/Mains MASTER LEDtube EM/Mains Photometric data
General Uniform Lighting 1 x TLED 18W 4000K 160D 9290012220 1 x 2500 lm Polar intensityo diagram
120o
120o
180
90o
90o
Quantity estimation diagram
UGR diagram
nr. of luminaires
16.0
hroom: 2.8 m Reflectances: 0.70, 0.50, 0.20 Maintenance factor: 1.0 Ceiling mounted
40
m 12.0 Y
50 60o
60o
100
30
750 lx
25
hroom: 2.8 m
28
Refl: 0.70 0.50 0.20 Ceiling mounted : viewed endwise
25
: viewed crosswise
25 Y : Parallel to viewing dir.
150
20
500 lx
200 250 30o
γ 30o
300 (cd/1000lm) 0o 0-180o
90-270
8.0
300 lx
10
4.0
0 10
30
50
70
90
(m2)
Utilisation factor table Light output ratio Service upward Service downward CIE flux code
1.00 0.14 0.86
40 69 88 86 100
UGRcen (4Hx8H, 0.25H)
4.0
8.0
o
25
0.60 0.80 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00
0.80 0.50 0.30 0.43 0.53 0.61 0.69 0.75 0.85 0.91 0.96 1.03 1.07
0.80 0.50 0.10 0.41 0.50 0.57 0.63 0.68 0.76 0.81 0.84 0.89 0.92
0.70 0.50 0.30 0.42 0.51 0.59 0.66 0.72 0.81 0.87 0.92 0.98 1.01
0.70 0.50 0.20 0.41 0.50 0.57 0.64 0.69 0.77 0.83 0.87 0.92 0.95
0.70 0.50 0.10 0.40 0.48 0.55 0.61 0.66 0.74 0.78 0.82 0.86 0.89
12.0
m
16.0
Luminance Table
Reflectances (%) for ceiling, walls and working plane (CIE) Room Index k
X
0.70 0.30 0.10 0.32 0.40 0.47 0.54 0.59 0.67 0.73 0.77 0.82 0.85
0.50 0.30 0.10 0.31 0.39 0.45 0.51 0.56 0.64 0.69 0.73 0.78 0.81
0.50 0.10 0.10 0.26 0.33 0.40 0.46 0.51 0.60 0.65 0.69 0.75 0.78
0.30 0.30 0.10 0.29 0.37 0.43 0.49 0.54 0.61 0.66 0.69 0.74 0.77
0.30 0.10 0.10 0.25 0.32 0.38 0.45 0.49 0.57 0.62 0.66 0.71 0.75
0.00 0.00 0.00 0.22 0.29 0.34 0.40 0.45 0.52 0.57 0.61 0.65 0.68
Plane Cone
0.0
15.0
30.0
45.0
60.0
75.0
90.0
45.0
9847
9973
10343
10970
11994
13712
16814
50.0
9221
9341
9699
10294
11267
12982
16371
55.0
8620
8736
9077
9627
10524
12165
15808
60.0
8048
8161
8481
8975
9760
11252
15075
65.0
7514
7616
7916
8344
8991
10214
14111
70.0
7020
7111
7390
7745
8232
9060
12798
75.0
6573
6656
6907
7194
7498
7794
11001
80.0
6181
6255
6483
6701
6829
6491
8325
85.0
5852
5913
6123
6288
6268
5317
90.0
5595
5648
5839
5970
5899
4580
4529 383
(cd/m2)
Ceiling mounted 2016-03-18
CalcuLuX Photometrics 4.5
Philips Lighting B.V.
Page: 1/1 2016, August 8 data subject to change
MASTER LEDtube EM/Mains MASTER LEDtube EM/Mains Intensity (%)
100 80 60 40 20 0 200
300
400
500
600
700
800 [nm]
© 2016 Philips Lighting Holding B.V. All rights reserved. Specifications are subject to change without notice. Trademarks are the property of Koninklijke Philips N.V. (Royal Philips) or their respective owners. www.philips.com/lighting
2016, August 8 data subject to change