Transcript
SUGGESTED SPECIFICATIONS FOR CONVEYOR MODEL SD-SC Soiled Dish Conveyor to be SOUTHERN ENGINEERING SYSTEMS by Duke Mfg Co., model SDSC, UL and ETL Listed, and NSF approved commercial kitchen conveyor. Conveyor Belt to be stainless steel roller type chain with removable, low friction acetal slats, 10" wide. Slats are individually removable from #60 stainless steel chain without the use of tools. Belt to operate at a variable speed of 5 to 40 feet per minute. Conveyor Bed to be constructed on #14 gauge, 300 series stainless steel with 3” high x 1-1/4” wide rolled rim on exposed sides and 10” high x 2-1/2” wide splash along walls. Polish stainless steel to a #3 finish. Belt channel to be fully enclosed and fitted with full length UHMWP wears strips. Belt returned via flanged non-friction PVC roller assemblies. Drive Housing to be a welded stainless steel frame with hinged, lift off, double wall, #16 gauge stainless steel access door exposing oversized, removable stainless steel scrap pan. Drive housing to be supported by four 1-5/8" O.D., #16 gauge stainless steel legs and stainless steel adjustable bullet feet. Drive Type to be 90-volt DC, ½ H.P. variable speed with 120volt, 60 cycle service, internal torque limit adjustment and ramp acceleration start. Controlled by one (1) on/off switch station and variable speed control. Drive end of conveyor furnished with concealed anti-jam Silver Saver switch plate to prevent foreign material from jamming drive system. Automatic Wash System to be provided with 1-1/2” drain and strainer at drive housing and fulllength, adjustable height, stainless steel drip pan. Wash system incorporates; mixing and check valves, brass spray nozzles and an adjustable detergent injector. Hot water and detergent continuously rinse and lubricate both sides of the belt. Conveyor supported by 1-5/8” 16gauge stainless steel tubing Legs with welded stainless steel cross rails. Leg frames fitted into enclosed, round stainless steel gussets welded to stainless steel channel braces and fitted with stainless steel adjustable bullet feet. Conveyor to be pre-wired and factory tested. Conveyor to carry UL and ETL listing and shall be NSF approved. Equipment built in an ISO
9001:2000 approved manufacturing facility.
BY "Your Solutions Partner"
2305 N. Broadway St. Louis, MO 63012 Ph 314-231-1130 Fax 314-231-5074 www.dukemfg.com 5/07
Optional Accessories 12” Slat-Chain Belt 10” Slat-Pin Belt @ 24” Radius (Model SD-SR) SS Window Frame & Sill Removable Skirting Panels – SS Removable Skirting Panels - Laminate Sight & Sound Barrier Security or Fire Door Flanged Feet Additional Start-Stop Station Foot Switch (Momentary Stop) Hip Switch (Constant Stop) Limit Switch – Bed Mount Limit Switch – Splash Mount Flush-Wash (Drip pan and Drains only.) Prison Security Package Power Tray Discharge (Drive End) Tray Storage Platform (Tail End) Other ____________________________ ____________________________
Design Option
Sloped Rack Shelf – Wall Mount Sloped Rack Shelf – Cantilevered Flat Storage Shelf - Wall Mount Flat Storage Shelf - Cantilevered Stationary Under Shelf Removable Under Shelf 3” High x 1-1/2” Channel Rim Sides 7/8” High x 1-1/4” Marine Edge 90 Degree Turn Special Turn Pre-Rinse Sink Disposer Sink Scrapping Trough Trough Wheels Recessed SS Roller Section Removable Skirting Panels Pre-Rinse Spray – Splash Mount Pre-Rinse Spray – Bed Mount.
(Pick One)
32” Long Drive Housing (Standard) 40” Long Drive Housing (Optional) COMMENTS/NOTES ____________________________________________________________
14GA SS FLAT STORAGE SHELF W/ ADJ 14GA SS SLEEVED BRACKETS & 16GA SS TUBING SUPPORTS
14GA SS SLOPED RACK SHELF W/ ADJ 14GA SS SLEEVED BRACKETS & 16GA SS TUBING SUPPORTS
1'-9" 2'-6" 1 1/4"
3"
10"
2'-10" A.F.F.
2'-10" A.F.F.
REMOVABLE 16GA SS ENCLOSURE PANELS
2 1/2"
10" BELT
3"
10" BELT
10"
2 1/2"
ADJ SS DRIP PAN 16GA SS LEGS WITH ADJ SS BULLET FEET
2'-10" A.F.F.
1 1/4"
UL MODEL #SD-SC10-AW-VS
'- " 32" DRIVE HOUSING
HW CW
12
10" HIGH SPLASH @ WALLS
4
21"
SILVER SAVER SWITCH
E
D 6
OPTIONAL 14GA SS REMOVABLE TRAY STACKING PLATFORM
5 - 40 F.P.M.
14GA SS SLIDER PAN W/ 1-1/4" ROLLED RIM
CONVEYOR UTILITIES CW HW D E
1/2" COLD WATER 1/2" HOT WATER 1-1/2" DRAIN Elec 120V-5AMP 3Wire
Stub-up 4" AFF Stub-up 4" AFF Indirect Stub-up 4" AFF
NOTE: CONVEYORS UP TO 40' WITHOUT INTERMITTANT DRAINS. (CONSULT FACTORY)
REMOVABLE 16GA SS SKIRTING
32" DRIVE HOUSING W/ HEAVY DUTY 304 S.S. STRUCTURAL FRAME, AUTOMATIC BELT WASHER W/ TIMED DETERGENT INJECTION, SLIDE OUT SCRAP PAN, DOUBLE PAN, 16GA S.S. HINGED & REMOVABLE ACCESS DOOR W/ RECESS HANDLE & MAGNETIC CATCH
ON/OFF SWITCH W/ SPEED CONTROL MASTER DISCONNECT
We reserve the right to change specifications and product design without notice. Such revisions do not entitle buyers to corresponding changes, improvements, additions or replacements for previously purchased equipment.
Model SD-SC
Item Number: ____________
RADIUS SLAT-BELT SOILED DISH CONVEYOR
SOUTHERN ENGINEERING SYSTEMS SOUTHERN ENGINEERING SYSTEMS Model SD-SC, UL and ETL Listed and NSF approved soiled dish conveyors are engineered to meet the unique design criteria required to satisfy client needs. These Soiled Dish conveyor systems utilize state-of-the-art components and CAD/CAM manufacturing techniques. The conveyor bed features ultra high molecular weight polyethylene (UHMWP) wear strips, and flanged PVC return rollers below significantly reducing drag resulting in lower horse power requirements, lower energy costs and perpetual bed life. Sealed for life bearings eliminate the cost of central lubrication systems and routine maintenance requirements. DC drive system and adjustable torque limit decreases operating expense and provides greater safety to operating personnel. Our extended life slat-chain belting allows an 18” turn radius and provide years of economical service with slats replaceable without tools.
SOUTHERN ENGINEERING SYSTEMS conveyors have been built to last by craftsman for over 52 years, carry an 18 month warranty, plus an additional 4 year motor warranty, and conform to or exceed all known federal regulatory requirements. PROJECT NAME: _____________________________ PROJECT LOCATION: _____________________________ SE-SDSC