Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

2 5 L1 460-60-3 POWER SOURCE L1 L2 L3 11 5 PIN PLUG FOR INDOOR BLOWER MOTOR L2 L3 RED 4 Fuse Fuse 1 RED BLACK 2 3 28 L1 T1 L2 T2 L3 T3 L2 L3 Compressor RED 27 12 11 10 9 8 7 6 5 4 3 2 1 BLACK/WHITE 1 3 2 4 5 1 45 35 20 35 36 24 Compressor Control Module LPC L2 L1 YELLOW BLACK L3 Compressor YELLOW 4 14 5 BLOWER VENT RELAY 2 12 PIN VENT PLUG 27 3 5 4 6 2 1 7 8 9 10 11 12 VOLTAGE STRIP Hi Pressure Control Low Pressure Control 1 3 4 5 6 7 8 9 10 11 12 1 2 3 10 12 PIN PLUG FOR THERMOSTAT YELLOW BLUE RED RED Reversing Valve G 1 C 2 Step Down Transformer 3 O 1 PURPLE BLUE/WHITE L A Terminal Block #1 ("A" Ctrl. Opt. Only) RED 3 REMOVE WIRE FROM TERMINAL Y2 AND TAPE OFF WHEN LOWER FULL LOAD CFM DESIRED NO ERV 3.2 3.2 3.2 5 C LPC 12 LOW BLACK/WHITE 2 REMOVE JUMPER WHEN CS2000 ENERGY MONITOR IS INSTALLED W / ERV 5 5 7 7 CC ALR R Y1 36 OPTIONAL 3 PIN PLUG FOR ERV BLUE BLUE High Speed Solenoid BLACK/WHITE 48 STEPDOWN TRANSFORMER CLASS CC FUSE Y Compressor Contactor W R 1 2 3 27 1 FOR ANTIFREEZE LOOP APPLICATIONS, CHANGE LOW PRESSURE SWITCH TO YELLOW LEADS ON YELLOW WIRES COMING OFF OF COMPRESSOR CONTROL MODULE "LPC" TERMINALS C E Y2 BLACK BLACK 15 33 Transformer 18 BLACK/WHITE Check Light MODEL QW2S QW3S QW4S QW5S C 2 BLACK 45 12 PIN VENT PLUG 2 12 3 1 BLACK/ WHITE 39 BLACK 32 460 VOLT PACKAGE UNIT DIAGRAM Y 19 GREEN COM ALR Fuse Block C R LPC LPC 39 Compressor Contactor RED 39 9 CC RED R 31 460V RED YELLOW 27 6 PIN CO2 PLUG PURPLE 6 GREEN BROWN BLACK/WHITE ORANGE 38 38 BROWN 10 13 14 15 6 HPC T1 T2 T3 BLACK 4 5 BLACK/WHITE L2 L3 BLUE YELLOW L1 GREEN 2 3 BLACK/WHITE L3 Yo 37 48 27 BROWN/WHITE 39 RED/WHITE BLACK/WHITE 1 38 42 Comp. Control Module YELLOW/RED 24 43 BLACK RED/ WHITE 38 RED/WHITE RED 41 BLACK YELLOW HPC Low Pressure Switch 16 PIN PLUG FOR 10 INDOOR BLOWER MOTOR O1 Y Y1 C RED/WHITE RED/WHITE RED RED 10 BLACK 33 L1 L2 L3 L2 Y 19 High Pressure Switch PINK 34 44 L1 24VAC C 21 Phase Monitor YELLOW 2 12 LOW VOLTAGE STRIP Transformer 4 Ground Terminal Y Yout COM RED 4 40 YELLOW 5 10 34 10 BLACK/W 1 BLOWER 14 VENT RELAY BLACK/ WHITE 10 27 YELLOW 10 PINK 7 8 9 10 11 12 10 10 3 YELLOW 30 ORANGE BROWN/ WHITE YELLOW RED BROWN RED/WHITE 5 6 ORANGE YELLOW YELLOW/BROWN 4 BLUE PURPLE 460 5 Rotary Disconnect 3 L1 29 46 Term. Block RED/YELLOW 1 2 230-60-1 19 Compressor Contactor 3 4 3 Step Down Ground Transformer Optional 3 Pin Plug For ERV 11 5 Pin Plug 5 for Indoor Blower Motor 460-60-3 POWER SOURCE 5 Circuit Breaker BLACK 4 GREEN 3 BLACK/ WHITE PINK RED/WHITE BROWN/WHITE O1 Y Y1 C Terminal Block #1 ("A" Ctrl. Opt. Only) BROWN BLUE GRAY YELLOW ORANGE PURPLE 12 PIN PLUG FOR THERMOSTAT 10 BLACK/WHITE 14 12 15 3 1 10 6 9 13 2 RED/WHITE 16 PIN PLUG FOR INDOOR BLOWER MOTOR 10 Low Pressure Control ! DANGER *ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING. 99 4 5 6 27 6 PIN CO2 PLUG ! WARNING Wire Identification numbers for Bard use only. Factory Field Optional High Voltage Low Voltage USE COPPER CONDUCTORS ONLY SUITABLE FOR AT LEAST 75° C. Bard Mfg. Co. Bryan, Ohio 4113-300 B