Transcript
Data sheet... RIDERSERIES RCIKIT 24VDC 2CO LD/FG
Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com
• Coupling relay with positively driven contacts: for monitoring signals within safety-critical circuits • Relays with positively driven contacts have a 99% diagnostics coverage and an excellent reputation for use in safety systems. • The contacts interlock with each other in order to ensure a synchronous switching status between both contacts. This guarantees that the alert contact will maintain the same switching status in the event of an error (for example, if the working contact melts from an overload).
General ordering data
Order No. Type Version GTIN (EAN) Qty.
1218410000 RCIKIT 24VDC 2CO LD/FG RIDERSERIES, Relays, No. of contacts: 2, CO contact, AgCuNi, Rated control voltage: 24 V DC, Continuous current: 6 A, Screw connection 4050118002416 10 pc(s).
Creation date November 19, 2012 2:21:41 PM CET
Catalogue status 06.11.2012 / We reserve the right to make technical changes.
1
Data sheet... RIDERSERIES RCIKIT 24VDC 2CO LD/FG
Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com
Technical data
Ratings
Conductor connection system UL 94 flammability rating
Humidity
15.5 mm 62 mm
Height Net weight
77 mm 60 g
-40 °C...+70 °C
Storage temperature
-40 °C...+85 °C
Clamping range, rated connection, min. 0.5 mm²
Power rating Status indicator
0.82 W
250 V AC 250 V 15 A / 20 ms 12 ms / 5 ms 20 mA
Max. switching voltage, AC Continuous current Max. switching power Min. switching power Max. switching frequency at rated load
250 V 6A 1500 VA 120 mW 20 Hz
2
Contact design Mechanical service life
CO contact
Clearance and creepage distances for control side - load side Surge voltage category
≥ 10 mm III
Free-wheel diode
Yes
Screw connection V-1
40 °C / 95 % rel. humidity, no condensation
Dimensions and weights Width Depth
Temperatures
Operating temperature
Connection data
Clamping range, rated connection 2.5 mm² Clamping range, rated connection, max. 2.5 mm²
Input
Rated control voltage 24 V DC Pull-in (sparkover) / drop-out voltage DC coil 16.8 V / 2.4 V
Green LED
Output
Rated switching voltage Max. switching voltage, DC making current Sparkover time / Drop-out time Min. switching current
Contact specifications No. of contacts Contact material
AgCuNi
> 50 x 106 switching cycles
Insulation coordination Rated voltage
Pollution severity
250 V 3
Other technical data Status indicator
Green LED
Further details of approvals / standards Standards
DIN EN 50205
Creation date November 19, 2012 2:21:41 PM CET
Catalogue status 06.11.2012 / We reserve the right to make technical changes.
2
Data sheet... RIDERSERIES RCIKIT 24VDC 2CO LD/FG
Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com
Technical data
Classifications ETIM 3.0 eClass 5.1 eClass 7.0
EC001437 27-37-16-01 27-37-16-01
UNSPSC eClass 6.0
30-21-18-01 27-37-16-01
Approvals
Approvals
Downloads
Declaration of Conformity
K354_09_10.pdf
Creation date November 19, 2012 2:21:41 PM CET
Catalogue status 06.11.2012 / We reserve the right to make technical changes.
3
Data sheet... RIDERSERIES RCIKIT 24VDC 2CO LD/FG
Drawings
Connection diagram
Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com
Derating curve
Creation date November 19, 2012 2:21:41 PM CET
Catalogue status 06.11.2012 / We reserve the right to make technical changes.
4