Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

    Data sheet... RIDERSERIES RCIKIT 24VDC 2CO LD/FG Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com     • Coupling relay with positively driven contacts: for monitoring signals within safety-critical circuits • Relays with positively driven contacts have a 99% diagnostics coverage and an excellent reputation for use in safety systems. • The contacts interlock with each other in order to ensure a synchronous switching status between both contacts. This guarantees that the alert contact will maintain the same switching status in the event of an error (for example, if the working contact melts from an overload). General ordering data   Order No. Type Version GTIN (EAN) Qty.   1218410000 RCIKIT 24VDC 2CO LD/FG RIDERSERIES, Relays, No. of contacts: 2, CO contact, AgCuNi, Rated control voltage: 24 V DC, Continuous current: 6 A, Screw connection 4050118002416 10 pc(s). Creation date November 19, 2012 2:21:41 PM CET   Catalogue status 06.11.2012 / We reserve the right to make technical changes. 1     Data sheet... RIDERSERIES RCIKIT 24VDC 2CO LD/FG   Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Ratings   Conductor connection system UL 94 flammability rating     Humidity     15.5 mm 62 mm     Height Net weight 77 mm 60 g -40 °C...+70 °C   Storage temperature -40 °C...+85 °C     Clamping range, rated connection, min. 0.5 mm²       Power rating Status indicator 0.82 W 250 V AC 250 V 15 A / 20 ms 12 ms / 5 ms 20 mA           Max. switching voltage, AC Continuous current Max. switching power Min. switching power Max. switching frequency at rated load 250 V 6A 1500 VA 120 mW 20 Hz 2     Contact design Mechanical service life CO contact     Clearance and creepage distances for control side - load side Surge voltage category ≥ 10 mm III   Free-wheel diode Yes     Screw connection V-1 40 °C / 95 % rel. humidity, no condensation Dimensions and weights   Width Depth   Temperatures   Operating temperature   Connection data   Clamping range, rated connection 2.5 mm² Clamping range, rated connection, max. 2.5 mm²   Input   Rated control voltage 24 V DC Pull-in (sparkover) / drop-out voltage DC coil 16.8 V / 2.4 V   Green LED Output   Rated switching voltage Max. switching voltage, DC making current Sparkover time / Drop-out time Min. switching current   Contact specifications   No. of contacts Contact material   AgCuNi > 50 x 106 switching cycles Insulation coordination   Rated voltage Pollution severity   250 V 3 Other technical data   Status indicator   Green LED Further details of approvals / standards   Standards   DIN EN 50205 Creation date November 19, 2012 2:21:41 PM CET   Catalogue status 06.11.2012 / We reserve the right to make technical changes. 2     Data sheet... RIDERSERIES RCIKIT 24VDC 2CO LD/FG   Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Classifications   ETIM 3.0 eClass 5.1 eClass 7.0   EC001437 27-37-16-01 27-37-16-01       UNSPSC eClass 6.0   30-21-18-01 27-37-16-01 Approvals   Approvals   Downloads   Declaration of Conformity   K354_09_10.pdf Creation date November 19, 2012 2:21:41 PM CET   Catalogue status 06.11.2012 / We reserve the right to make technical changes. 3     Data sheet... RIDERSERIES RCIKIT 24VDC 2CO LD/FG   Drawings Connection diagram Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Derating curve Creation date November 19, 2012 2:21:41 PM CET   Catalogue status 06.11.2012 / We reserve the right to make technical changes. 4