Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

CONTROL CABLES FOR VERTICAL APPLICATIONsN PANZERFLEX®-VS Standards: according to VDE 0250 part 814 ….. PANZERLITE … Standards: according to VDE 0250 part 814…… MAIN APPLICATION High Flexible control cables specially designed when high tensile tension is requested. These cables have a standard 2000N tensile load and are indicated to be used on equipments such as: rack and pinion elevators using sheave guided cables, container crane spreader reels, pendant stations, all tenders, etc. 20 rue de la GIRINE 38460 SAINT ROMAIN de JALIONAS ( France ) Tel : +33 (0)4 37 06 11 51 - Fax +33 (0)4 37 06 11 52 WEB : www.demoonline.fr - email : [email protected] CONTROL CABLES FOR VERTICAL APPLICATION PANZERFLEX-VS® 0.6/1kV CONSTRUCTION 1. 2. 3. 4. 5. 6. 7. TEMPERATURE RATINGS Kevlar® central strainer Very flexible tinned stranded copper conductor EPR based compound insulation Tape Polychloroprene based compound inner sheath Antitwisting protection of synthetic yarns Yellow polychloroprene based compound outer sheath N° of cores and nominal cross section Code mm² Nominal conductor diameter 90°C Maximum conductor temperature -20°C Minimum ambient temperature during work RATED AND TEST VOLTAGES Max D.C. Electr. Res. At 20°C Overall diameter mm 0,6/1kV 1.2 kV 1.8 kV Rate voltage: A.C. nominal Uo/U A.C. max Um D.C. max Um 2,5 kV A.C. Test voltage Weight for 1000m Maximum permissible Tensile Load mm² Ohm/km min max Kg/km N 600 2000 7 x 1.5 G5GOV098 1.6 13.7 18.4 20.4 12 x 1.5 G5GOV099 1.6 13.7 24.2 26.2 980 2000 18 x 1.5 G5GOV100 1.6 13.7 24.4 26.4 1040 2000 24 x 1.5 G5GOV101 1.6 13.7 27.5 30.5 1320 2000 30 x 1.5 G5GOV103 1.6 13.7 31.1 34.1 1690 2000 36 x 1.5 G5GOV105 1.6 13.7 31.3 34.8 1750 2000 7 x 2.5 G5GOV108 2.1 8.21 20.9 22.9 790 2000 12 x 2.5 G5GOV109 2.1 8.21 28.2 30.2 1300 2000 18 x 2.5 G5GOV110 2.1 8.21 28.3 31.3 1500 2000 24 x 2.5 G5GOV111 2.1 8.21 32.8 35.8 1920 2000 30 x 2.5 G5GOV113 2.1 8.21 36.9 39.9 2360 2000 36 x 2.5 G5GOV115 2.1 8.21 37.1 40.6 2530 2000 7x4 G5GOV135 2.7 5.09 23.6 25.6 1020 2000 12 x 4 G5GOV136 2.7 5.09 32.4 34.4 1750 2000 18 x 4 G5GOV137 2.7 5.09 33.4 36.4 2050 2000 20 rue de la GIRINE 38460 SAINT ROMAIN de JALIONAS ( France ) Tel : +33 (0)4 37 06 11 51 - Fax +33 (0)4 37 06 11 52 WEB : www.demoonline.fr - email : [email protected] CONTROL CABLES FOR VERTICAL APPLICATIONSS PANZERLITE 0.6/1kV 1 This new cable has been developed and 2 designed in order to meet special 5 conditions of application, in particular 3 where small dimensions and light weight 6 are mandatory. 4 Among its main features we can define: . small dimension . lighter weight . excellent flexibility . high operating speed (up to 260m/1’) . tension load up to 4000N . excellent mechanical performances 7 CONSTRUCTION 1. 2. 3. 4. 5. 6. 7. Kevlar® central strainer Extra flexible tinned stranded copper conductor Insulation of special tecnopolymer Tape Inner sheath made of special polyurethane PUR Antitwisting Kevlar® braid Yellow outer sheath made of special polyurethane PUR TEMPERATURE RATINGS 90°C Maximum conductor temperature -30°C Minimum ambient temperature during work RATED AND TEST VOLTAGES MINIMUM BENDING RADII: 18 x 2.5 37 x 2.5 42 x 2.5 N° of cores and nominal cross section 140 mm 195 mm 200 mm Code mm² Nominal conductor diameter Max D.C. Electr. Res. At 20°C 0,6/1kV 1.2 kV 1.8 kV Rate voltage: A.C. nominal Uo/U A.C. max Um D.C. max Um 2,5 kV A.C. Test voltage Overall diameter mm Weight for 1000m Maximum permissible Tensile Load Kg/km N mm² Ohm/km max 18 x 2.5 65358 2.2 8.21 23.0 770 2000* 37 x 2.5 65999 2.2 8.21 32.3 1500 4000 42 x 2.5 66330 2.2 8.21 33.5 1650 4000 Other sizes or configurations are available on specific request * available, on request, with 4000N 20 rue de la GIRINE 38460 SAINT ROMAIN de JALIONAS ( France ) Tel : +33 (0)4 37 06 11 51 - Fax +33 (0)4 37 06 11 52 WEB : www.demoonline.fr - email : [email protected]