CQ 1 FORM C AUTOMOTIVE SILENT RELAY
CQ RELAYS (ACQ)
FEATURES
TYPICAL APPLICATIONS
• Sound pressure reduced by approx. 20 dB from that of the company’s non-silent relays • Space saving • Adopting standard terminal pitch (for compact relays) • Plastic sealed type • Wiper load models are listed
For intermittent wipers and applications requiring quiet operation
ORDERING INFORMATION CQ
-
Contact arrangement 1: 1 Form C W1: 1 Form C for wiper load Coil voltage (DC) 12 V
TYPES Contact arrangement 1 Form C 1 Form C for wiper load
Coil voltage
Model No. ACQ131 ACQW131
12V DC
Part No. CQ1-12V CQ1W-12V
Standard packing; Carton (tube): 40 pcs.; Case: 800 pcs.
RATING 1. Coil data Nominal coil voltage
Pick-up voltage (at 20C 68F)
Drop-out voltage (at 20C 68F)
Nominal operating current [10%] (at 20C 68F)
Coil resistance [10%] (at 20C 68F)
Nominal operating power
Usable voltage range
12V DC
Max. 7.2V DC (Initial)
Min. 1.0V DC (Initial)
53.3 mA
225
640 mW
10 to 16V DC
Note: Other pick-up voltage types are also available. Please contact us for details.
ds_61208_en_cq: 310113D
1
CQ 2. Specifications 1) Standard CQ relay Characteristics
Contact
Rating
Electrical characteristics
Mechanical characteristics
Item Arrangement Contact resistance (Initial) Contact voltage drop Contact material Nominal switching capacity (resistive load)
Nominal operating power Min. switching capacity (resistive load)*1
Specifications 1 Form C N.O.: Typ7m, N.C.: Typ8m (By voltage drop 6V DC 1A) Max. 0.2V (at 10 A) Ag alloy (Cadmium free) N.O.: 20A 14V DC, N.C.: 10A 14V DC N.O.: 35A for 2 minutes, 25A for 1 hour (at 20C 68F) 30A for 2 minutes, 20A for 1 hour (at 85C 185F) 640 mW 1A 14V DC
Insulation resistance (Initial)
Min. 100 M (at 500V DC, Measurement at same location as “Breakdown voltage” section.)
Between open contacts Between contacts and coil Operate time (at nominal voltage) Release time (at nominal voltage) Functional Shock resistance Destructive Functional Vibration resistance Destructive
500 Vrms for 1 min. (Detection current: 10mA) 500 Vrms for 1 min. (Detection current: 10mA) Max. 10ms (at 20C 68F, excluding contact bounce time) (Initial) Max. 10ms (at 20C 68F, excluding contact bounce time) (Initial) Min. 100 m/s2 {10G} (Half-wave pulse of sine wave: 11ms; detection time: 10s) Min. 1,000 m/s2 {100G} (Half-wave pulse of sine wave: 6ms) 10 Hz to 100 Hz, Min. 44.1 m/s2 {4.5G} (Detection time: 10s) 10 Hz to 500 Hz, Min. 44.1 m/s2 {4.5G} Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours Min. 107 (at 120 cpm) Min. 105 (at nominal switching capacity, operating frequency: 1s ON, 9s OFF) Min. 3105 (Inrush 30A, steady 5A, 20A 14V DC at brake current) (Operating frequency: 1s ON, 2s OFF) Ambient temperature: –40C to +85C –40F to +185F Humidity: 5% R.H. to 85% R.H. (Not freezing and condensing at low temperature) 6 cpm (at nominal switching capacity) Approx. 6.5g .23 oz
Max. carrying current (12V DC initial)*3
Breakdown voltage (Initial)
Mechanical Expected life
Conditions
Electrical*4
Conditions for operation, transport and storage*2 Max. operating speed
Mass
Notes: *1.This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2.The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information. *3.Depends on connection conditions. Also, this does not guarantee repeated switching. We recommend that you confirm operation under actual conditions. *4.Motor load does not apply to wiper load applications.
2) For wiper load (ACQW131) Anything outside of that given below complies with standard CQ relays. Characteristics Rating
Item Max. carrying current (12V DC initial)*1
Expected life
Electrical
Specifications N.O.: 25A for 1 minutes, 15A for 1 hour (at 20C 68F) N.O. side: Min. 5105 (Inrush 25A, steady 6A 14V DC) N.C. side: Min. 5105 (12A 14V DC at brake current) (Operating frequency: 1s ON, 9s OFF)
Note: *1. Depends on connection conditions. Also, this does not guarantee repeated switching. We recommend that you confirm operation under actual conditions.
2
ds_61208_en_cq: 310113D
CQ REFERENCE DATA 40
(N.O. side Room temperature)
35
Coil applied voltage, VDC
60 Switching voltage, VDC
2. Ambient temperature and operating voltage range
50 40 30 20
30 25 20
10
10 0
Operating voltage range
15
5
0
10
20 30 40 Switching current, A
0 −40 −20
50
3. Ambient temperature characteristics 80
Ratio against the rated voltage, %
1. Max. switching capability (Resistive load, initial)
70 Pick-up voltage upper limit
60 50 40 30 20
Pick-up voltage lower limit 10
Pick-up voltage (Cold start) 0 20 40 60 8085 100 120 Ambient temperature, °C
0
−40
85 20 Ambient temperature, °C
4. Distribution of pick-up and drop-out voltage
5. Distribution of operate time
6. Distribution of release time
Sample: ACQ131, 100pcs
Sample: ACQ131, 100pcs
Sample: ACQ131, 100pcs
Quantity, n
Quantity, n
50 40 30 20 10
100
100
90
90
80
80
70
70
Quantity, n
Pick-up voltage Drop-out voltage
60 50
40 30
20
20
10
10
9 7 6
Pick-up voltage Max. x Min.
5 4 Drop-out voltage
2
Max. x Min. 0
10 25 No. of operations, × 104
8.-(2) Operation noise distribution
When operate
When release
25
25
20
20 Quantity, n
Quantity, n
8.-(1) Operation noise distribution
10
5
5
50
52
ds_61208_en_cq: 310113D
54
56
3
3.5
N.C. side N.O. side 40
30 Max. x Max. Min. x Min.
20
50
10
0
0
10 25 No. of operations, × 104
0
50
Measuring conditions Sample: ACQ131, 50 pcs. Equipment setting: “A” weighted, Fast, Max. hold Coil voltage: 12V DC Coil connection device: Diode Background noise: Approx. 20dB
15
10
Noise level, dB
2.5
3
0
48
2
50
8
1
15
1.5
Change of contact resistance
10
M
46
1
Time, ms
Change of pick-up and drop-out voltage Pick-up and drop-out voltage, V
Sample: ACQW131 Quantity: n = 3 Load: N.O. side: Inrush 25A, steady 6A 14V DC N.C. side: Brake current 12A 14V DC Operating frequency: ON 1s, OFF 9s Ambient temperature: Room temperature Circuit
44
0.5
Time, ms
7. Electrical life test for wiper load (motor free)
42
0
0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5
Voltage, V
0
50
30
0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0
* Without diode
60
40
Contact resistance, mΩ
60
Microphone Relay
50mm 1.969inch Sponge
38
40
42
44
46
48
50
52
Noise level, dB
3
CQ DIMENSIONS (mm inch)
CAD Data Data from our Web site. Download CAD
External dimensions
CAD Data 17.0 .669
PC board pattern (Bottom view) 5×1.5+0.1 0 dia. 5×.059+.004 dia. 0
13.0 .512
10.0 .394
16.6 .654 Max. 1.0 .039
0.4 .016
CAD Data 3.5 .138 5×0.25 5×.010
10.2 .402
2.5 .098
Tolerance: 0.1 .004
*A 5×1.2 Pre-soldering 5×.047
Schematic (Bottom view) NO
10.0 .394
1.5 .059 2.5 .098
10.2 .394
COM
Dimension: Max. 1mm .039 inch: 1 to 3mm .039 to .118 inch: Min. 3mm .118 inch:
Tolerance 0.1 .004 0.2 .008 0.3 .012
COIL NC
* Dimensions (thickness and width) of terminal is measured before pre-soldering. Intervals between terminals is measured at A surface level.
For Cautions for Use, see Relay Technical Information.
4
ds_61208_en_cq: 310113D