Preview only show first 10 pages with watermark. For full document please download

Similar Pages

   EMBED


Share

Transcript

Pub. 42004-636L2B GAI-TRONICS® CORPORATION A HUBBELL COMPANY Model 12576-125 Access Panel with VFD Confidentiality Notice This manual is provided solely as an operation, installation, and maintenance guide and contains sensitive business and technical information that is confidential and proprietary to GAI-Tronics. GAI-Tronics retains all intellectual property and other rights in or to the information contained herein, and such information may only be used in connection with the operation of your GAI-Tronics product or system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third party. Introduction The Model 12576-125 Access Panel is a component of the SmartSeries system that can be used for public address, intercommunication, and emergency notification. How to Use the Assembly Application The Model 12576-125 Access Panel is a standard EIA 19-inch rack-mount assembly with a 120 V ac/240 V ac power input. This power input allows the access panel to be used in almost all installations without requiring additional line transformers. The access panel can be used to initiate alarms, and to monitor system activity via a vacuum fluorescent display (VFD). A piezo audible alarm is included, which is typically used to alert personnel of updated system status. The panel provides a handset equipped with an integral pressbar. The handset is used to make page announcements and to hold two-way party line conversations. The main components of the Model 12576-125 Access Panel are as follows: • • • • Vacuum fluorescent display 27 push buttons Handset Piezo alarm The function of each of the 27 push buttons is software configurable. Contact GAI-Tronics for more information on configuration of the access panel. Of the 27 push buttons, 23 contain an LED lamp that can be configured to provide system status information. The four remaining push buttons, including the lower push button to the right of the VFD and the lower three push buttons in the rightmost column of five switches, contain non-functional LEDs. These non-functional LEDs may be used as spares. GAI-Tronics Corporation 400 E. Wyomissing Ave. Mohnton, PA 19540 USA 610-777-1374 „ 800-492-1212 „ Fax: 610-796-5954 VISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS Model 12576-125 Access Panel with VFD Hardware Configuration Figure 1. Model 12576-125 Access Panel (Front View) f:\standard ioms - current release\42004 instr. manuals\42004-636l2b.doc 11/10 Pub. 42004-636L2B Page: 2 of 8 Model 12576-125 Access Panel with VFD Pub. 42004-636L2B Page: 3 of 8 Interfaces A three-conductor ac power cord is included with the access panel. One end of the power cord is connected to the three-prong connector located on the back of the access panel, while the other end is plugged into a grounded ac electrical outlet. The compatible ac input voltages are 120 V ac /240 V ac (auto-ranging), 50/60 Hz. Data and audio connection to the system control unit is provided by a four-position terminal block located at the rear of the panel. The physical connection is a single twisted-pair cable connection using two of the four terminal points. One of the remaining two points is tied to chassis ground and may be used to connect to a cable shield if shielded cable is preferred. NOTE: Ensure that only one end of the cable’s shield is grounded in order to avoid ground loops. The remaining terminal point is not used. A second four-position terminal block is provided for optional connections: • • Two terminals are available to connect a single 40-ohm (nominal) external speaker for page audio monitoring. Two terminals are available to drive an external piezo alarm. Contact GAI-Tronics Service Department for further information. NOTE: The piezo alarm is a polarity-sensitive device. Ensure that proper polarity is observed when connecting it to the access panel. Figure 2. Model 12576-125 Access Panel Typical Connections (Rear View) f:\standard ioms - current release\42004 instr. manuals\42004-636l2b.doc 11/10 Model 12576-125 Access Panel with VFD Pub. 42004-636L2B Page: 4 of 8 Installation WARNING Please adhere to all warnings, safety, and operating instructions on the unit and in the installation manual. 1. Disconnect power before servicing. 2. Avoid servicing the unit during electrical storms. 3. Do not touch uninsulated wires. Mounting NOTE: Mounting hardware is not included with this assembly and must be purchased separately. Remove the access panel from its protective packing. Position the access panel in the 19-inch EIA enclosure and secure it with the appropriate screws. When installed correctly, the handset will be on the left side of the access panel. Data Connection Connect a twisted-pair cable from the access panel terminal block points labeled VOICE/DATA COM. to the corresponding connector on the appropriate termination block of the control unit. This connection is not polarity-sensitive and may be wired in either orientation. A chassis ground (labeled E-GND) is also provided on this terminal block to connect to a cable shield, if shielded cable is used. NOTES: 1. The data cable is not included with this assembly and must be purchased separately. 2. If shielded cable is used, only one end of the cable’s shield should be grounded in order to avoid ground loops. External Speaker Connection Connect the optional external 40-ohm speaker to the access panel at the terminal block points labeled SPKR+/- at the back of the unit. Contact GAI-Tronics Service Department for further information. NOTE: The optional external speaker is not included with this assembly and must be purchased separately. External Piezo Alarm Connection Connect the optional external piezo alarm to the access panel at the terminal block points labeled PIEZO ALARM+/- at the back of the unit. Contact GAI-Tronics Service Department for further information. NOTES: 1. The optional external piezo alarm is not included with this assembly and must be purchased separately. 2. The external piezo alarm is a polarity-sensitive device and care must be taken to ensure that proper polarity is observed when connecting it to the access panel. f:\standard ioms - current release\42004 instr. manuals\42004-636l2b.doc 11/10 Model 12576-125 Access Panel with VFD Pub. 42004-636L2B Page: 5 of 8 Power Connect the three-conductor ac power cord provided with the access panel as follows: 1. Loosen the captive screw on the connector lock of the three-prong power connector at the rear of the access panel. 2. Plug one end of the power cord into the three-prong power connector at the rear of the access panel. 3. Tighten the captive screw in order to clamp the connector lock around the power cord. Plug the other end into a grounded ac electrical outlet. 4. The access panel does not contain an internal power switch. The access panel will power up immediately. Push Button Overlay To install or replace the push button overlay, proceed as follows: 1. Loosen the eight mounting screws located along the edge of the existing push button overlay using a 1/16-inch Allen wrench or equivalent. Save these mounting screws. 2. Lift the existing push button overlay away from the access panel. 3. Mount the new push button overlay onto the access panel, aligning the screw-holes on the overlay with those on the access panel. 4. Replace and tighten the eight mounting screws using a 1/16-inch Allen wrench or equivalent. f:\standard ioms - current release\42004 instr. manuals\42004-636l2b.doc 11/10 Model 12576-125 Access Panel with VFD Pub. 42004-636L2B Page: 6 of 8 Operation Operation of this assembly is highly dependent on the attached system’s software configuration. The software is factory-created and subsequently downloaded to the system control unit via an external PC at system start-up. This access panel offers the following standard features in addition to the configurable features. The standard features include a handset used for page and party functions, a vacuum fluorescent display (VFD) used to provide system status in a text format, and a piezo alarm that can be activated to alert a user of a change in system status. Handset Communications The handset is used for both page and party communications. Lifting the handset from the cradle creates an off-hook condition. In a normal configuration, lifting the handset causes it to be connected to a party line. Vacuum Fluorescent Display (VFD) and Control The VFD displays status messages from the system control unit in a text format. Typically, the push buttons to the right of the VFD are configured for NEXT and PREVIOUS functions. Use the NEXT push button to view each additional new message. The NEXT push button can be configured to flash when a new message is available. Use the PREVIOUS to cycle backward in order to review old status messages. Piezo Alarm The piezo alarm is an audible indicator. It is typically configured to sound when a new message is available on the VFD. If configured as described above, press the NEXT push button to display each new message. When the last available new message has been displayed, the piezo alarm turns off. The exact details of the operation of the piezo alarm are configurable. f:\standard ioms - current release\42004 instr. manuals\42004-636l2b.doc 11/10 Pub. 42004-636L2B Page: 7 of 8 Model 12576-125 Access Panel with VFD How to Diagnose Assembly Faults Servicing Guidelines 1. Notify plant personnel of a system shutdown prior to servicing the unit. 2. Disconnect power before connecting external wiring or installing or removing the access panel. Symptom Action Access panel does not function. (No push buttons detected, no LED lamps activate, VFD is blank, and handset is not functioning.) • Verify ac power is applied to access panel. Verify that ac power cord is plugged in. Also verify that ac outlet is active. • Verify that the twisted-pair data cable is properly connected between the access panel and the control unit. • Call for service of the access panel. No push buttons are detected. • Verify that the twisted-pair data cable is properly connected between the access panel and the control unit. • Call for service of the access panel. Some push buttons are not detected. Call for service of the access panel. No LED lamps activate. • Verify that the twisted-pair data cable is properly connected between the access panel and the control unit. • Call for service of the access panel. Some LED lamps do not activate. • Verify that none of the potentially faulty LED lamps are in the set of 4 inactive LED lamps (the 3 lower LED lamps located in the rightmost column and the lower LED lamp to the right of the VFD.) • Verify that an LED lamp is installed in the faulty illuminated push button(s). • Replace the faulty LED lamp(s). • Call for service of the access panel. Call for service of the access panel. Piezo alarm does not function. VFD does not function, even during a lamp test. Call for service of the access panel. Handset does not function properly. Call for service of the access panel. External speaker interface does not function. • Verify wiring between the speaker connector on the access panel and the speaker itself. • Determine if speaker is faulty by connecting a different speaker to the speaker interface and verifying operation. • Call for service of the access panel. f:\standard ioms - current release\42004 instr. manuals\42004-636l2b.doc 11/10 Pub. 42004-636L2B Page: 8 of 8 Model 12576-125 Access Panel with VFD Specifications Electrical Input voltage ..................................................................................................................... 120 V ac/240 V ac Auto-ranging Input frequency ................................................................................................................................ 50/60 Hz Input current draw.................................................................................................... 1 amp max. @ 120 V ac Line length ....................................................................3.0 km with No. 24 AWG, attenuation = 8.0 dB/km 2.2 km with No. 26 AWG, attenuation = 11.5 dB/km Environmental Operating temperature range.................................................................. +32° F to +120 °F (0° C to +49° C) Relative humidity.................................................................................................Non-condensing 85% max. Mechanical Unit dimensions ....................................... 12.25 H × 19.00 W × 9.13 D inches (311.2 × 482.6 × 232.2 mm) Unit weight.........................................................................................................................................12.9 lbs. Handset material ........................................................................................................................... Black ABS Handset microphone ..............................................................................................Dynamic, noise-canceling Handset receiver.............................................................. Dynamic, hearing aid compatible per FCC part 68 Handset cord ....................................................................................... Hytrel, 6-foot (1.8 m) when extended Handset cradle............................................................................................Fixed. Built-in off-hook detector External controls ............................................................................................................ Press-to-page switch 27 configurable push buttons Approval CE Mark Replacements Parts Model Number Description 12509-009 LED Lamp Replacement Kit 54003-001 LED Lamp Holder Tool 54003-002 Lens Removal Tool 61002-007 Replacement Line Cord Reference Material Reference to Assembly/Model Drawings Published by Title GAI-Tronics Ref. No. GAI-Tronics Model 12576-125 Access Panel Outline 72121 f:\standard ioms - current release\42004 instr. manuals\42004-636l2b.doc 11/10 Warranty Equipment. GAI-Tronics warrants for a period of one (1) year from the date of shipment, that any GAI-Tronics equipment supplied hereunder shall be free of defects in material and workmanship, shall comply with the then-current product specifications and product literature, and if applicable, shall be fit for the purpose specified in the agreed-upon quotation or proposal document. If (a) Seller’s goods prove to be defective in workmanship and/or material under normal and proper usage, or unfit for the purpose specified and agreed upon, and (b) Buyer’s claim is made within the warranty period set forth above, Buyer may return such goods to GAI-Tronics’ nearest depot repair facility, freight prepaid, at which time they will be repaired or replaced, at Seller’s option, without charge to Buyer. Repair or replacement shall be Buyer’s sole and exclusive remedy. The warranty period on any repaired or replacement equipment shall be the greater of the ninety (90) day repair warranty or one (1) year from the date the original equipment was shipped. In no event shall GAI-Tronics warranty obligations with respect to equipment exceed 100% of the total cost of the equipment supplied hereunder. Buyer may also be entitled to the manufacturer’s warranty on any third-party goods supplied by GAI-Tronics hereunder. The applicability of any such third-party warranty will be determined by GAI-Tronics. Services. Any services GAI-Tronics provides hereunder, whether directly or through subcontractors, shall be performed in accordance with the standard of care with which such services are normally provided in the industry. If the services fail to meet the applicable industry standard, GAI-Tronics will re-perform such services at no cost to buyer to correct said deficiency to Company's satisfaction provided any and all issues are identified prior to the demobilization of the Contractor’s personnel from the work site. Re-performance of services shall be Buyer’s sole and exclusive remedy, and in no event shall GAITronics warranty obligations with respect to services exceed 100% of the total cost of the services provided hereunder. Warranty Periods. Every claim by Buyer alleging a defect in the goods and/or services provided hereunder shall be deemed waived unless such claim is made in writing within the applicable warranty periods as set forth above. Provided, however, that if the defect complained of is latent and not discoverable within the above warranty periods, every claim arising on account of such latent defect shall be deemed waived unless it is made in writing within a reasonable time after such latent defect is or should have been discovered by Buyer. Limitations / Exclusions. The warranties herein shall not apply to, and GAI-Tronics shall not be responsible for, any damage to the goods or failure of the services supplied hereunder, to the extent caused by Buyer’s neglect, failure to follow operational and maintenance procedures provided with the equipment, or the use of technicians not specifically authorized by GAI-Tronics to maintain or service the equipment. THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE IN LIEU OF AND EXCLUDE ALL OTHER WARRANTIES AND REMEDIES, WHETHER EXPRESS OR IMPLIED BY OPERATION OF LAW OR OTHERWISE, INCLUDING ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Return Policy If the equipment requires service, contact your Regional Service Center for a return authorization number (RA#). Equipment should be shipped prepaid to GAI-Tronics with a return authorization number and a purchase order number. If the equipment is under warranty, repairs or a replacement will be made in accordance with the warranty policy set forth above. Please include a written explanation of all defects to assist our technicians in their troubleshooting efforts. Call 800-492-1212 (inside the USA) or 610-777-1374 (outside the USA) for help identifying the Regional Service Center closest to you. (Rev. 10/06)