Transcript
Photometric Outdoor Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002
Prepared For
Eye Lighting International of North America Jerry Catherine 9150 Hendricks Road Mentor, OH 44060
Catalog Number
RW-L750-27-UX-XX Project Number
10007208 Test Number
137048
Test Date 2013-03-28 Prepared By
Approved By
Kyle Spaziani, Project Coordinator
Eric Gaudreau, Project Coordinator
The results contained in this report pertain only to the tested sample. This report shall not be reproduced, except in full, without written approval of Underwriters Laboratories.
Test Number 137048 - Page 1 of 10
Luminaire Description: Catalog Number: Lamp: Mounting: Ballast/Driver:
Cast aluminum heatsink housing, no enclosure RW-L750-27-UX-XX 32 white LEDs with clear plastic optics below each Pole Arm One Inventronics EUC-075S280DT
Luminaire
Test Conditions Test Temperature: Voltage: Current: Power: Power Factor: Frequency: Current THD:
25.6 120.0 0.6066 72.41 0.994 60 5.66
°C VAC A W Hz %
Test Number 137048 - Page 2 of 10
*** THIS IS AN ABSOLUTE TEST REPORT *** UTILIZATION TABLE CO-EFFICIENT OF UTILIZATION RATIO
HOUSE SIDE
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 5.0 TOTAL:
STREET SIDE
TOTAL
0.210 0.348 0.395 0.411 0.418 0.421 0.424 0.425 0.427
0.224 0.405 0.497 0.531 0.545 0.550 0.554 0.556 0.559
0.433 0.753 0.892 0.943 0.963 0.971 0.978 0.981 0.986
0.432
0.566
0.998
PERCENTAGE OUTPUTS DOWNWARD:
UPWARD:
STREET SIDE =
56.6%
HOUSE SIDE
=
43.2%
TOTAL
=
99.8%
STREET SIDE =
0.1%
HOUSE SIDE
=
0.1%
TOTAL
=
0.2%
EFFICACY (LUMENS PER WATT)
91.2
THE ABOVE COEFFICIENTS HAVE BEEN CALCULATED BASED ON LUMINAIRE LUMENS BECAUSE IN AN ABSOLUTE TEST THE BARE LAMP LUMENS ARE UNKNOWN. LIGHTING DESIGN CALCULATIONS MADE USING THESE COEFFICIENTS SHOULD THEREFORE USE THE LUMINAIRE LUMENS IN THE CALCULATION FORMULA
Test Number 137048 - Page 3 of 10
IESNA CUTOFF CLASSIFICATION: SEMICUTOFF LUMINAIRE OUTPUT: 6600 Lms. ZONAL LUMEN SUMMARY PER IES PUBLICATION TM-15-07 *** THIS IS AN ABSOLUTE TEST REPORT ***
FORWARD LIGHT: LUMENS
3733.3
% LUMENS FORWARD FORWARD FORWARD FORWARD
56.6 % LOW ZONE (0 TO 30 DEGREES) MID ZONE (30 TO 60 DEGREES) HIGH ZONE (60 TO 80 DEGREES) VERY HIGH ZONE (80 TO 90 DEGREES)
7.5 28.5 19.2 1.4
% % % %
BACK LIGHT: LUMENS
2854.4
% LUMENS BACK BACK BACK BACK
LIGHT LIGHT LIGHT LIGHT
43.2 % LOW ZONE (0 TO 30 DEGREES) MID ZONE (30 TO 60 DEGREES) HIGH ZONE (60 TO 80 DEGREES) VERY HIGH ZONE (80 TO 90 DEGREES)
7.4 22.0 12.8 1.1
% % % %
UPLIGHT: LUMENS
12.4
% LUMENS
0.2 %
UPLIGHT LOW ZONE (90 TO 100 DEGREES) UPLIGHT HIGH ZONE (100 TO 180 DEGREES)
TRAPPED LIGHT: NOT APPLICABLE TO AN ABSOLUTE TEST
Test Number 137048 - Page 4 of 10
0.1 % 0.1 %
IES "BUG" RATING (BACK LIGHT, UPLIGHT, GLARE) PER IES TM-15-11 LUMENS
SECONDARY SOLID ANGLE RATING
BACK LIGHT BH (60-80 DEGREES) BM (30-60 DEGREES) BL (0-30 DEGREES)
841.6 1455.0 488.0
B 2 B 2 B 1
3.9 8.5
U 1 U 1
UPLIGHT UH (100-180 DEGREES) UL (90-100 DEGREES) GLARE LIGHT FVH (80-90 DEGRESS) BVH (80-90 DEGRESS) FH (60-80 DEGREES) BH (60-80 DEGRESS)
IES BUG RATING:
90.5 69.8 1266.8 841.6
B2
U1
G G G G
1 1 1 2
G2
LABORATORY RESULTS MAY NOT BE REPRESENTATIVE OF FIELD PERFORMANCE. BALLAST FACTORS HAVE NOT BEEN APPLIED TESTED IN 30 PLANES LEFT SIDE, 30 PLANES RIGHT SIDE, LEFT AND RIGHT AVERAGED VERTICAL TEST INCREMENTS ARE 2.5 DEGREES. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE
Test Number 137048 - Page 5 of 10
INTENSITY(CANDLEPOWER) IN MAX. PLANE
INTENSITY(CANDLEPOWER) IN MAX. CONE
ANGLE
ANGLE
0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 52.5 55.0 57.5 60.0 62.5 65.0 67.5 70.0 72.5 75.0 77.5 80.0 82.5 85.0 87.5 90.0 95.0 105.0 115.0 125.0 135.0 145.0 155.0 165.0 175.0 180.0
CANDLEPOWER 1022 1020 1048 1110 1193 1288 1389 1479 1566 1685 1879 2000 2144 2303 2483 2703 2968 3223 3383 3313 2826 1929 1048 512 247 117 51 9 1 1 1 1 0 0 0 0 0
150
180
150
0.0 5.0 15.0 25.0 35.0 45.0 55.0 60.0 62.5 65.0 67.5 70.0 72.5 75.0 77.5 80.0 82.5 85.0 87.5 90.0 95.0 105.0 115.0 125.0 135.0 145.0 155.0 165.0 175.0 180.0
120
120
90
90
2000 60
60 4000 30
0
30
MAXIMUM INTENSITY(CANDLEPOWER):
3383 CD
PLANE OF MAXIMUM:
80.0
VERTICAL ANGLE OF MAXIMUM:
70.0
Test Number 137048 - Page 6 of 10
CANDLEPOWER 239 237 260 294 360 535 1296 2224 2607 2882 3069 3201 3295 3357 3381 3383 3328 3209 3040 2866 2678 2602 1706 490 188 163 157 150 151 150
VERT. ANGLE 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 55.0 60.0 65.0 70.0** 75.0 80.0 85.0 90.0
0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 55.0 60.0 65.0 70.0** 75.0 80.0 85.0 90.0
INTENSITY(CANDLEPOWER) SUMMARY HORIZONTAL ANGLES - STREET SIDE 25.0 35.0 45.0 55.0 65.0 75.0
0.0
5.0
15.0
1022 1012 1029 1075 1123 1171 1216 1267 1329 1360 1294 1041 610 335 239 182 95 45 10
1022 1011 1033 1078 1124 1176 1223 1276 1335 1359 1274 999 583 326 237 176 98 44 10
1022 1013 1036 1081 1131 1197 1257 1314 1380 1414 1343 1088 657 365 260 190 97 52 14
90.0
HORIZONTAL ANGLES - HOUSE SIDE 95.0 105.0 115.0 125.0 135.0 145.0 155.0 165.0 175.0 180.0
1022 1028 1057 1118 1194 1285 1378 1448 1517 1591 1721 1912 2139 2476 2866 2369 847 201 44
1022 1026 1060 1119 1200 1292 1389 1475 1546 1637 1782 1962 2123 2375 2678 2285 795 199 49
1022 1029 1066 1131 1219 1318 1426 1528 1631 1760 1907 2068 2237 2447 2602 2010 722 197 55
1022 1014 1034 1083 1147 1233 1325 1407 1484 1548 1512 1273 841 449 294 212 105 64 21
1022 1035 1070 1133 1218 1311 1412 1523 1639 1743 1842 1951 2033 1939 1706 1253 511 173 53
1022 1014 1034 1086 1166 1276 1405 1517 1634 1722 1725 1539 1148 642 360 230 115 63 23
1022 1034 1068 1123 1194 1273 1371 1494 1606 1684 1716 1624 1303 816 490 285 167 88 29
1022 1014 1033 1095 1191 1318 1471 1616 1750 1867 1932 1861 1577 1059 535 290 141 56 18
1022 1036 1063 1106 1158 1227 1324 1428 1509 1529 1392 1029 575 308 188 145 123 67 19
1022 1014 1034 1099 1201 1330 1488 1655 1799 1950 2108 2236 2254 1983 1296 635 262 85 24
1022 1038 1060 1085 1119 1180 1260 1329 1359 1272 1001 619 356 212 163 148 132 69 15
1022 1016 1039 1102 1202 1326 1463 1615 1760 1919 2131 2397 2655 2811 2882 2265 1047 270 55
1022 1040 1057 1069 1092 1139 1190 1214 1171 1002 715 443 275 186 157 157 142 82 14
1022 1020 1044 1105 1195 1301 1407 1519 1639 1785 1992 2291 2645 3045 3357 2842 1129 269 55
1022 1038 1049 1053 1069 1106 1133 1110 1001 810 577 375 237 171 150 155 126 35 8
80.0 **** 1022 1020 1048 1110 1193 1288 1389 1479 1566 1685 1879 2144 2483 2968 3383 2826 1048 247 51
1022 1037 1047 1048 1059 1089 1102 1053 917 719 518 344 217 167 151 162 97 15 1
85.0 1022 1024 1055 1116 1195 1283 1373 1445 1518 1609 1763 1993 2289 2746 3209 2706 971 233 47
1022 1035 1043 1043 1059 1084 1091 1027 874 671 482 318 201 160 150 150 82 3 0
** DENOTES VERTICAL ANGLE OF MAXIMUM CONE **** DENOTES LATERAL ANGLE OF MAXIMUM PLANE INTENSITY WAS MEASURED IN 2.5 DEGREE STEPS - TABULATIONS ARE AVAILABLE
Test Number 137048 - Page 7 of 10
** ILLUMINANCE(FOOTCANDLE) TABLE FOR SINGLE LUMINAIRE AT 25.0 FT. ** LATERAL RATIOS -3.00 + + + + + + + + + + + + + + + .008 .008 .007 .006 .005 .004 .003 .003 .002 .002 .002 .002 .002 .001 .001 | -2.50 + + + + + + + + + + + + + + + .012 .012 .011 .009 .007 .005 .005 .004 .005 .005 .004 .003 .002 .002 .001 | -2.00 + + + + + + + + + + + + + + + .024 .024 .020 .015 .011 .012 .013 .015 .013 .010 .007 .004 .003 .002 .002 | -1.50 + + + + + + + + + + + + + + + .076 .076 .057 .040 .043 .050 .047 .035 .023 .015 .009 .006 .004 .003 .002 | -1.00 + + + + + + + + + + + + + + + 0.38 0.41 0.32 0.23 0.18 0.13 .094 .059 .035 .020 .012 .007 .005 .003 .002 | -0.50 + + + + + + + + + + + + + + + 1.2 1.2 0.84 0.51 0.31 0.20 0.12 .075 .042 .024 .014 .008 .005 .003 .002 HOUSE | CURB LINE -------- + -- + -- + -- + -- + -- + -- + -- + -- + -- + -- + -- + -- + -- + -- + -STREET 1.6 1.5 0.90 0.53 0.33 0.22 0.14 .084 .047 .026 .015 .009 .005 .004 .002 | 0.50 + + + + + + + + + + + + + + + 1.3 1.4 0.97 0.62 0.39 0.25 0.16 .095 .053 .029 .017 .010 .006 .004 .003 | 1.00 + + + + + + + + + + + + + + + 0.77 0.74 0.57 0.42 0.29 0.20 0.13 .086 .050 .029 .017 .010 .006 .004 .003 | 1.50 + + + + + + + + + + + + + + + 0.25 0.22 0.18 0.13 0.11 0.10 .087 .063 .041 .026 .016 .009 .006 .004 .003 | 2.00 + + + + + + + + + + + + + + + .057 .053 .048 .040 .030 .030 .028 .029 .025 .019 .013 .009 .006 .004 .003 | 2.50 + + + + + + + + + + + + + + + .022 .021 .020 .017 .014 .010 .011 .009 .010 .010 .009 .007 .005 .003 .002 | 3.00 + + + + + + + + + + + + + + + .011 .011 .011 .009 .007 .006 .005 .004 .004 .004 .004 .004 .003 .003 .002 | 3.50 + + + + + + + + + + + + + + + .006 .006 .006 .005 .004 .003 .003 .002 .002 .002 .002 .002 .002 .002 .002 | 4.00 + + + + + + + + + + + + + + + .004 .004 .003 .003 .003 .002 .002 .002 .001 .001 .001 .001 .001 .001 .001 | 4.50 + + + + + + + + + + + + + + + .002 .002 .002 .002 .002 .001 .001 .001 .001 .001 .001 .001 .001 .000 .001 | 5.00 + + + + + + + + + + + + + + + .001 .001 .001 .001 .001 .001 .001 .001 .001 .001 .000 .000 .000 .000 .000 | 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 LONGITUDINAL MOUNTING HEIGHT RATIOS CORRECTION FACTORS FOR OTHER MOUNTING HEIGHTS: SEE ISOFOOTCANDLE PAGE
Test Number 137048 - Page 8 of 10
MOUNTING HEIGHT FOR ISOFC 25.0 FEET 3
H O U S E
Mounting HT. 10.00 15.00 20.00 25.00 35.00 45.00 50.00
2
Multiplier - FEET - 6.25 - 2.78 - 1.56 - 1.00 - 0.51 - 0.31 - 0.25
1 COEFFICIENT OF UTILIZATION DASHED CURVES
CURB LINE S T R E E T
0.1
1
0.2
0.3
0.4
0.5
0.6
1.00 0.50 0.20
0.10
2
0.05 0.02
3
0.01
4
5
0 RATIO =
1 DISTANCE ALONG MOUNTING HEIGHT
2
3
0.01 0.02 0.05 0.1 0.2 0.5 1 2 5
4
10 20 50 100 200 500 1000 2000 5000
Test Number 137048 - Page 9 of 10
5
10000 20000 50000
6
7
RATIO OF TRANSVERSE DISTANCE TO MOUNTING HEIGHT 1 R A T I O O F L O N G I T U D I N A L D I S T A N C E T O NOTE: CONTOUR LINE IS FOR 50% OF THE MAXIMUM INTENSITY
M O U N T I N G H E I G H T
0
0
LUMINAIRE
1
2
3
4
5
6
0 10 20
1
30
50
60 120 60 110100 70 90 80 2
50
40
S H O R T
T R A N S V E R S E
M E D I U M
70
3 75
4 L O N G
5 80
R O A D W A Y
6 TYPE I
L I N E S
7 82.5
8
* T R L *
TYPE II
9 TYPE III
10 TYPE IV
11
85
LONGITUDINAL ROADWAY LINES *LRL*
IES ROADWAY CLASSIFICATION: TYPE III, MEDIUM Test Number 137048 - Page 10 of 10