Wiring and programming
22mm
Keyfob 58.5mm
ÿ
Keyfob SS/F & SS/F/UB
Reader SS/01 & SS/01/UB
Standards
RTT&E Directive: EN 300 330 and EN 301-489; BS EN 50130-4
Power
-
13.8V dc from panel +/- 5% maximum 75mA
Minimum range
20mm from centre of depression
keyfobs
8 maximum per reader
Dimensions
58.5 x 18.5mm
118 x 84 x 22mm
Weight
4g
114g
Colour
Dark Grey Polycarb.
Mounting
-
Screws (not supplied)
Indications
-
Day - (green) Learn - (amber) Power, Zone, Error - (red) TA, and PA - (red)
ÿ ÿ
ensure the Tamper wiring is connected to the reader
ÿ
where more than one reader is installed in a system ensure they are at least 1m distance apart
NOTE: At least one keypad must be installed in the system. The keypad is necessary for manual operation of the system during normal use and for engineering it the during commissioning and maintenance.
TAMP
SOUND
COMMS
0V
13V
How to connect the Simple Set Reader to a G3 intruder panel with Software versions 1.2 (26/11/01), 1.1 (12/09/01), 1.0 (08/06/01) Cable distance 100m maximum Simple Set Reader Board
OPTI-CAM Lighting Controller Board
RELAY
Keypad Board
TAMP
Reader PCB (Board)
Panel
SOUND COMMS
Board
13V
RKP FUSE
0V
F2
1A
SOUND COMMS +13V 0V
Maximum of up to 4 Remote Keypad / Simple Set Reader / OPTI-CAM Lighting Controller combination allowed
Press
Prog
9
9
9
9
J2
TAMP
5 Zone configuraion
8
5
Zone 8#
Reset
Reset
Zone 8
J5
Where there is only one keypad and it is part of the panel then connect the TAMP back to the panel
Zone configured to accept a Keyswitch input
How to program Zone 8 for keyswitch input Engineer Progam Mode
Reset
Keyswitch Input Zone
Lt
d
# Enter appropriate zone number if it is not zone 8
re
How to connect the Reader to an Accenta 8 Panel
TAMP
Cable distance 100m maximum
RELAY
Simple Set Reader
TAMP
tS en
COMMS
Board
0V
Tamper breakout Cover fixing screw
If required, cut-out the appropriate thinned section on the base for cable entry.
Base
TAMP
Panel
SOUND COMMS
Board
13V 0V
Cover assembly
1A TAMP
Tamper Spring
SOUND
COMMS F2 +13V
Route the external cable through the base and fix the base using the two mounting points. Connect the external cable to the terminal block on the cover assembly, see also wiring diagrams.
RELAY
Keypad
WD1
+13V
llig 6- Thinned Cable sections entry for cable entry point
If the keypad is part of the panel then connect the TAMP back to the panel
Board
SOUND
Clip the cover assembly to the base and ensure the tamper spring locates into the collar on the base & . Secure the cover assembly to the base using the cover fixing screw .
4188-726 issue 1_06/02
Tamper Spring
J5
Where there is only one keypad and it is part of the panel then connect the TAMP back to the panel
0V
Maximum of up to 4 Remote Keypad / Simple Set Reader combination allowed
PTS J5
How to program PTS as a remote keyswitch input Press
Prog
9
9
9
9
Engineer Progam Mode
6 Flag Configuration
5 Keyswitch input
Reset
PTS configured to accept a Keyswitch input
RKP FUSE
when using a keyfob, always hold the keyfob perpendicular to the surface of the reader to achieve maximum range, see photo above.
0V TAMP
Cable distance 100m maximum
te
test the operation of the reader(s) using the keyfobs
You must now test the system to check the reader provides zone, tamper and attack indications.
F2
+13V
Maximum of up to 4 Remote Keypad / Simple Set Reader / OPTI-CAM Lighting Controller combination allowed
You can now set and unset the system using the keyfobs supplied with the reader, see operating instructions.
JUMPER P2
ec
mount each reader away from metal surfaces and large metal objects
In
ÿ ÿ
Mounting points
Base
Fi
check the Simple set reader can be connected to your intruder system and ensure the panel software is compatible, see wiring and programming
Tamper spring locating collar Cover assembly
&
ÿ
ensure you install the reader near entry/exit route to allow the system to be fully set or unset
Once you have connected the reader to your intruder panel you will need to power up the system. On powering up, the system will go into alarm. At a keypad enter the user code and reset the system. The Power and Day indicator should now be lit at all keypads and also at the readers.
NOTE: If you have additional keyfobs or have acquired new keyfobs to replace lost ones, then you will need to learn the keyfobs, see how to learn instructions.
Mounting the reader
ity
Plan the installation work
ÿ
White ABS
ur
ÿ ÿ
ÿ
0 to +55ºC
Temperature
Do’s Before you begin installation work do ensure you read these instructions.
ÿ
If the system requires programming to accept a keyswitch input, then follow the how to program instructions accompanying the appropriate wiring details.
RKP FUSE
1A
COMMS
TAMP
SS/F/UB - Unbranded keyfob
118mm
Check the panel software is compatible to allow connection of the reader. The panel software version is normally printed on the microprocessor label. The microprocessor is located on the centre of the PCB.
SOUND
SS/F - Branded keyfob
ÿ
Board
13V
SOUND
COMMS
ÿ ÿ
SS/01/UB- Unbranded Simple Set Reader with 2 pre-learnt Keyfobs and a link
8
13V
ÿ
SS/01- Branded Simple Set Reader with 2 pre-learnt keyfobs and a link
7
COMMS 0V
0V
ÿ
6
18.5mm
The simple set reader is suitable for installation in a range of intruder systems. It allows the system to be fully set and unset using a keyfob. A reader can learn to operate with up to eight keyfobs. Each keyfob is unique and can only be used if it is recongised by the reader, this provides total security. There can be more than one reader installed in a system. These instructions cover information on how to mount and wire the reader, how to engineer the panel and learn up to eight keyfobs to a reader and how to fully set and unset the system using a keyfob. The products covered in these instructions are:
5
Panel
SOUND
TAMP
4
TAMP
SOUND
3
Board
COMMS
2
If you are installing the reader to an existing system then you will need to power down the system, note a tamper alarm will occur.
RELAY
Keypad
0V
1
OPTI-CAM Lighting Controller Board
13V
ÿ
ZONE
Check the panel type is compatible to allow reader(s) to be connected to the system, see wiring diagrams.
GND
84mm
ÿ
Board
12V
PA
GND
TA
SOUND
Learn Error
COMMS
Day
12V
Power
Simple Set Reader
LD R
Reader
How to connect the Simple Set Reader to a G3 intruder panel with Version 2.1 (30/04/02) or above
COMMS
The simple set reader can be connected to a G3 or Accenta intruder panel. It may be possible to connect the reader to other intruder systems having keyswitch input option, for further information call Technical Support.
SOUND
Engineering information
Technical Data
LD R
Simple Set Reader and Keyfobs
Simple Set Reader and Keyfobs Operating instructions
The reader mimics all the system indications given at other keypads in your system. The tamper indication is given by the indicator marked TA and personal attack by the indicator marked PA.
How to set the system
How to learn keyfobs if none are recognised You will only need to learn keyfobs in this manner if no keyfobs are recognised by the reader. A reader can learn up to 8 keyfobs following power up of the intruder system. You must have all the keyfobs to be learnt available. Keyfobs can be learnt by each reader installed in a system JUMPER
link fitted
Ensure the reader is connected to the intruder system and the JUMPER link is fitted on the reader PCB.
Reader cover assembly Reader PCB
JUMPER TAMP
P2
Power up the intruder system and enter the User code at the system keypad to unset the system. You will hear five rapid beeps to acknowledge the reader is in the Learn mode. Remove the JUMPER link from the reader PCB.
TAMP SOUND COMMS
WD1
+13V 0V
POWER UP THE SYSTEM
x 5 rapid beeps
1
3
2
4
5
6
The system will now produce the exit beep tone and you should leave the premises by the exit route recommended by your installer. The system will set when the exit beep tone stops.
8
7
Reader
Offer keyfob to the Reader and withdraw
Power
Day
Learn Error
TA
PA
2
3
4
5
6
7
8
link removed
The learn mode will NOT timeout until the first keyfob is learnt.
Power Day Learn Error TA PA
Power Day Learn Error TA PA
If you set/unset the system from a reader and subsequently unset/set the system using the keypad, then in some installations you may need to operate the system twice at the reader to allow the reader relay to catch up.
5
6
8
7
1
2
3
4
5
6
Power
Hold
Day
TA
Hold the first keyfob slightly touching it on the centre depression of the reader. Once the first keyfob is acknowledged by the reader the ZONE 1 light changes from flashing to steady and there is a recognition beep given by the local sounder. Withdraw the learnt keyfob. The reader is now ready to learn the next keyfob, signalled by flashing of ZONE 2 indicator.
PA
1
2
3
4
5
6
8
Power Day Learn Error TA PA
Offer keyfob to the Reader and withdraw
Power
Day
Learn Error
TA
PA
2
3
4
5
Power
ZONE 12
3
4
5
6
7
8
If any Zone, Tamper or Attack indicator lights up then an alarm has occurred, and an intrusion may have taken place. Seek assistance before investigating further as intruders may still be on the premises. Then reset the system at the system keypad. If you do not withdraw keyfob after it is recognised by the reader, you run the risk of entering the learn mode.
Keyfob recognition beep
6
2
3
4
5
Day
Learn Error
TA
7
8
ZONE 2
3
4
5
6
7
8
Next keyfob
keyfob recognised beep
You now have up to 10 seconds to learn the next keyfob.
Power Day Learn Error TA PA
Error
Error beep
7
8
3
4
5
6
8
7
2
3
4
5
6
7
Power
Day
Learn Error
TA
PA
ZONE 1
2
3
4
5
6
7
8
New keyfob
keyfob recognised beep Power Day Learn Error TA PA
ZONE 1
Repeat
Power Day Learn Error TA PA
2
3
4
5
6
7
8
to learn the next keyfob.
Once all the keyfobs are recognised ‘learnt’ by the Reader wait for just over 10 seconds and the reader will exit the learn mode, this is announced by two beeps from the local sounder and return to Day mode indication.
ZONE 1
2
3
4
5
6
7
8
what it means..
and what you could do.
The jumper link on the PCB has been left fitted following learn operation
Remove the jumper link and keep in safe place for future use.
Non volatile memory (NVM) communication error
Re-learn all keyfobs and if problem persists then contact technical support for help
You are using an already learnt keyfob during learn operation or you are offering an unlearnt keyfob to the reader during normal use
Offer an unlearnt or learnt keyfob respectively.
ZONE 1
2
3
4
5
Hold the recognised ‘learnt’ keyfob such that it touches the centre depression on the Reader and keep it there without movement for 10 seconds. You will hear a keyfob recognition beep and 10 seconds later five rapid beeps from the local sounder. You are now in the learn mode. The Learn light will give a flashing indication and the ZONE lights change from flashing to steady On indication to show recognised or learnt keyfob. The reader is now ready to learn the new keyfobs signalled by the next flashing ZONE indicator. Withdraw the keyfob.
Power
Power Day Learn Error TA PA
3
8
7
Learn Error
TA
PA
2
4
Offer the new keyfob slightly touch it on the centre depression of the reader. A learnt indication is given of the new keyfob when the flashing ZONE indicator changes to steady On indication and there is a recognition beep given by the local sounder. Shortly after the next numbered ZONE indicator will start flashing. Withdraw the learnt keyfob.
5
6
7
8
to learn the new keyfob.
Once all the keyfobs are recognised ‘learnt’ by the reader wait for just over 10 seconds for the reader to exit the learn mode, this is announced by two beeps from the local sounder and return to Day mode indication.
3
4
5
6
7
8
Learnt keyfob
keyfob recognised beep Power Day Learn Error TA PA
ZONE 1
2
3
4
5
6
7
8
7
8
x 5 rapid beeps Power Day Learn Error TA PA
ZONE 1
2
3
4
5
6
x 5 rapid beeps Day
Learn Error
TA
PA
ZONE 1
2
3
4
5
6
7
8
Next keyfob
keyfob recognised beep Power Day Learn Error TA PA
ZONE 1
2
3
4
5
6
Ensure the reader is in the day mode with the Day light lit. You must have one learnt keyfob and up to 7 further keyfobs to be learnt. Have all the keyfobs available. When an unrecognised keyfob is offered to the reader it will cause the Error light to be lit and continuous sound to be emitted from the local sounder. Hold the recognised ‘learnt’ keyfob slightly touching the centre depression on the reader and keep it there without movement for 20 seconds. Initially you will hear a keyfob recognition beep and 10 seconds later five rapid beeps from the local sounder. After 20 seconds you will hear another keyfob recognition beep tone from the local sounder. You are now in the learn mode. The Learn light will give a flashing indication and the ZONE 1 light changes from flashing to steady On indication to recognise the learnt keyfob. The reader is now ready to learn the next keyfob, signalled by the flashing of ZONE 2 indicator. Withdraw the learnt keyfob. In the learn mode when an already learnt keyfob is offered to the reader, an Error indication will be given.
Reader
The learn mode will timeout after 10 seconds if no actions is taken to learn new keyfob
Repeat
ZONE 2
Day
1
7
8
The learn mode will timeout after 10 seconds if no actions is taken to learn the next keyfob Offer the next keyfob slightly touch it on the centre depression of the reader. A learnt indication is given of the next keyfob when the flashing ZONE indicator changes to steady On indication and there is a recognition beep given by the local sounder. Shortly after the next numbered ZONE indicator will start flashing. Withdraw the learnt keyfob. You now have up to 10 seconds to start learning the another keyfob.
You now have up to 10 seconds to learn another new keyfob.
x 2 beeps
1
6
Reader Hold for 20 seconds
Power
8
x 2 beeps
When an unrecognised keyfob is offered to the reader it will cause the Error light to be lit and continuous sound is emitted from the local sounder.
In the learn mode when an already learnt keyfob is offered to the reader, an Error indication will be given.
ZONE 1
Fault finding Indication given.. Error fast rate flash twice per second Error slow rate flash 1s On and 1s Off
6
Indication given assumes 2 keyfobs were previously learnt by the reader
Offer the next keyfob slightly touching it on the centre depression of the reader. A learnt indication is given of the next keyfob when the flashing ZONE indicator changes to steady On indication and there is a recognition beep given by the local sounder. Shortly after the next numbered ZONE indicator starts flashing. Withdraw the learnt keyfob.
PA
llig 6
5
Reader
In
1
4
8
7
te
ZONE
3
ZONE 2
en
Power Day Learn Error TA PA
2
Power Day Learn Error TA PA
1
By entering the learn mode in this manner you will erase all recognition of previously learnt keyfobs at the reader, except for the one used to enter the learn mode.
ZONE
ZONE 1
The system will stop the entry beep tone and light the green Day indicator.
Reader
8
keyfob recognised beep
Enter your premises by the route recommended by your installer. The system will produce an entry beep tone.
7
PA
Fi
4
TA
x 5 rapid beeps
&
3
7
ity
2
Learn Error
tS
1
6
first keyfob
1
ZONE
5
Reader
Offer a keyfob to the reader and withdraw it as soon as you hear the keyfob recognition beep tone from the local sounder.
Day
keyfob recognised beep
Learn Error
When you enter your premises you will need to unset (or turn off) the system.
Power Day Learn Error TA PA
Hold for 10 seconds
8
7
Reader
How to unset the system Entry beep
Power
re
4
8
7
Learnt keyfob
ur
3
2
6
ec
ZONE 1
5
Reader
ZONE
Once a set/unset operation is performed using the keyfob, wait for 5 seconds duration before next use of the keyfob to operate the system.
Exit beep
4
ZONE
ZONE
Keyfob recognition beep
3
1
If you do not withdraw keyfob after it is recognised by the reader, you run the risk of entering the learn mode.
ZONE 1
JUMPER
2
d
ZONE
Ensure the reader is in the day mode with the Day light lit. You should have one learnt keyfob and the new keyfobs available.
ZONE 1
Using a recognised learnt keyfob the reader can re-learn up to 8 keyfobs. You may want to do this after a keyfob is lost or stolen and you want to prevent the use of it to operate the system. Keyfobs must be learnt by each reader installed in a system Power Day Learn Error TA PA
Power Day Learn Error TA PA
Lt
The Day indicator should be lit at the reader. Offer a keyfob to the reader and withdraw it as soon as you hear the keyfob recognition beep tone from the local sounder.
How to re-learn all keyfobs
Using a recognised learnt keyfob the reader can learn further keyfobs. A total of 8 keyfobs are recognised by a reader. You may want to do this if you have acquired additional keyfobs. Using these procedures the reader will still memorise previously learnt keyfobs. New keyfobs must be learnt by each reader installed in a system.
RELAY
When you leave your premises you will need to set (or turn on) the intruder alarm system. Before setting the system you should ensure that the premises have been completely vacated and that all doors and windows are closed. Ensure that pets do not have access to the protected areas as they can cause a false alarm. Power Day Learn Error TA PA
How to learn new keyfobs
x 2 beeps
Repeat
Power Day Learn Error TA PA
ZONE 1
2
3
4
5
6
7
8
Registered installers should refer to their supplied contact details.
to learn the next keyfob.
Once all the keyfobs are recognised ‘learnt’ by the reader wait for just over 10 seconds for the reader to exit the learn mode, this is announced by two beeps from the local sounder and return to Day mode indication.
For Technical Support : 0906 302 0999
This is a premium rate line, calls are charged at 50 pence per minute. The product conform to the requirements of the European EMC and Low Voltage directives, and carries the CE mark.
Novar ED&S The Arnold Centre Paycocke Road Basildon SS14 3EA 4188-726 issue 1_06/02