Transcript
500 A Huntmar Park Drive
ASTi Simulated PRC-117 Panel Operator Guide for Voisus Server
Document: DOC-VS-PRC117-OG
Advanced Simulation Technology inc.500A Huntmar Park Drive, Herndon, Virginia, 20170 USA Revision C (September, 2012)
Product Name: ASTi Simulated PRC-117 Panel
ASTi Simulated PRC-117 Panel Operator Guide for Voisus Server © Copyright ASTi 2011-2012. Restricted Rights: Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013. This material may be reproduced by or for the U.S. Government pursuant to the copyright license under the clause at DFARS 252.227-7013 (1994). ASTi 500-A Huntmar Park Drive Herndon, VA 20170
Table of Contents 1.0. GETTING STARTED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Basic Overview .............................................................................................................................. 1
2.0. PANEL FUNCTIONAL DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 3.0. HARDWARE AND SOFTWARE OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 System Hardware .......................................................................................................................... 3
4.0. SYSTEM INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Installation Technical Specifications .......................................................................................... 4 Figure 1: Example Layout .......................................................................................................... 5 Panel Hardware Installation ......................................................................................................... 6 Figure 2: PRC-117 Panel Rear View ......................................................................................... 6 Figure 3: PRC-117 Panel connection to ACE-RIU ..................................................................... 6 Audio / PTT Ancillary Connection ............................................................................................... 7 Figure 4: Handset Connection ................................................................................................... 7 Figure 5: Headset and PTT Connection .................................................................................... 8
5.0. PRC-117 PANEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Panel Configuration Mode ............................................................................................................ 9 Panel Operation ........................................................................................................................... 12 Backlight Display ...................................................................................................................... 13 Volume Display ........................................................................................................................ 14 Plain Text Mode ....................................................................................................................... 15 Cipher Text Mode .................................................................................................................... 17 SINCGARS Operation ............................................................................................................. 18 HAVE QUICK Operation .......................................................................................................... 19
6.0. PANEL TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 7.0. PHYSICAL INTERFACES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 8.0. FURTHER READING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
i
ii
ASTi Simulated PRC-117 Panel Operator Guide (Ver. 1, Rev. C)
1.0. GETTING STARTED This document presents a complete product description of ASTi's high fidelity-simulated PRC117 radio panel including the basic functional description of the PRC-117 panel, use with ASTi's Voisus Server and Remote Management System, as well as detailed hardware and software descriptions.
Basic Overview The PRC-117 panel provides a realistic panel user interface that works in conjunction with ASTi's radio communications software running on a Voisus Server. When the operator changes the state of the PRC-117 panel switch settings, the panel sends data through the Ethernet interface over the ACENet network to the Voisus Server. The Voisus Server software processes the switch settings and keypad sequences and converts them into control values. Then it sends panel display messages back over the ACENet network to the PRC-117 panel.
Copyright © 2012 Advanced Simulation Technology inc.
1
ASTi Simulated PRC-117 Panel Operator Guide (Ver. 1, Rev. C)
2.0. PANEL FUNCTIONAL DESCRIPTION The PRC-117 panel features a front panel rotary mode knob, keypad and an LED display with realistic messages. Operators use the PRC-117 panel to adjust radio parameters, including: • Single Channel Tuned Frequency / Channels • Volume control and volume display • Frequency Hopsets • COMSEC functions (including CT mode and crypto alarms) • Transmit and receive power level display with live updating • Plain-text and cipher-text mode • Net preset +/- buttons to scroll through the nets defined in the comm plan • Net frequency view in detailed submenu Built-in configuration and status mode provides support for the following: • Self-test • IP address, multicast, and port settings • Link status • Set panel name The built-in handset interface provides the capability to connect a real world PRC-117 handset with PTT switch to the PRC-117 panel. This interface serves as an analog ‘feed-through’ to the ACE-RIU audio interface. An alternative is to directly connect audio ancillaries to the ACE-RIU. This option allows the use of many types of headsets, mics, speakers and PTTs.
2
Copyright © 2012 Advanced Simulation Technology inc.
ASTi Simulated PRC-117 Panel Operator Guide (Ver. 1, Rev. C)
3.0. HARDWARE AND SOFTWARE OVERVIEW System Hardware QTY
Description
1
Simulated PRC-117 Panel
1
Power Supply Detachable Cordset
1
DB9 Cable, Straight, 4-6 Feet
A minimally configured system consists of this base hardware: (1) Voisus Server (1) ASTi Approved ACENet Ethernet Switch (1) Simulated PRC-117 Panel (1) ACE-Remote Interface Unit (ACE-RIU) (1) Headset or Handset with PTT switch Important: An ASTi simulated PRC-117 system is comprised of an integrated set of hardware and software components. Consult with an ASTi engineer before designing, expanding or upgrading your system.
Copyright © 2012 Advanced Simulation Technology inc.
3
ASTi Simulated PRC-117 Panel Operator Guide (Ver. 1, Rev. C)
4.0. SYSTEM INSTALLATION Installation Technical Specifications PRC-117 • Connect up to twenty PRC-117 panels to a single Voisus Server (TBD) • From one to four PRC-117 panels can be connected to a single ACE-RIU. • Panels can be located up to 4-6 feet from their associated ACE-RIU - this is in compliance with best engineering practices relating to maximum lengths of audio and control cables. ACE-RIUs • Each ACE-RIU is identified with a unique address number that is located on the rear of the device. In addition, the connected ACE-RIUs are listed on the RMS Utilities>ACENet tab. • ACE-RIUs are connected to the ACENet network using an ASTi approved ACENet Ethernet switch. • Every ACE-RIU has four DB-9 connectors, each of which will support one panel. These connectors are named A, B, C, and D, from left-to-right. • Refer to the ACE-RIU Technical User Guide (DOC-01-TEL4-AR-UG-1) for full product details. • ACE-RIU internal jumper settings are configured for use with Telex headsets. Contact ASTi for further information on jumper settings. • Use only the ASTi 15 Volt Power Supply provided with the ACE-RIU. Using a substitute power supply may void your factory warranty. Audio / PTT Ancillaries • Only the approved version PRC-117 handset may be connected to the PRC-117 front panel. • A variety of mics, speakers, PTTs may be connected directly to the ACE-RIU. If this option is selected, an adapter cable is needed to interconnect the audio / PTT devices to the ACERIU channel. Some audio devices cannot be directly connected to an ACE-RIU channel and may require intermediate interface circuitry.
4
Copyright © 2012 Advanced Simulation Technology inc.
ASTi Simulated PRC-117 Panel Operator Guide (Ver. 1, Rev. C)
Voisus Server
Switch
Switch
ACE-RIU CHAN A
CHAN B
CHAN C
CHAN D
Advanced Simulation Technology, Inc.
Handset
PRC-117F #1
PRC-117F #2
PRC-117F #3
PRC-117F #4
Optional additional switch depending on network setup.
Figure 1: Example Layout The example layout includes: • One (1) Voisus Server • Two (2) ACENet approved Ethernet Switch • One (1) ACE-RIU • Four (4) PRC-117 panels • Approved handsets connected to PRC-117 panels
Copyright © 2012 Advanced Simulation Technology inc.
5
ASTi Simulated PRC-117 Panel Operator Guide (Ver. 1, Rev. C)
Panel Hardware Installation Follow these steps to connect each panel to an associated ACE-RIU and the ACENet network. Refer to the figure below for a rear panel view of the PRC-117 panel.
Power connection
ACENet connection
POWER +15VDC
ACE-RIU connection
NETWORK AUDIO/PTT
STATUS
S/N:
ADVANCED SIMULATION TECHNOLOGY INC.
XXXXXXXXXXXX
Figure 2: PRC-117 Panel Rear View 1. Connect the power cable to the power connector (labeled “POWER +15VDC”). 2. Connect the Ethernet cable to the RJ-45 connector (labeled “NETWORK”) using a category 5e or better cable. This connects to the ACENet switch. 3. Connect the panel's audio interface cable to the DB-9 connector (labeled “AUDIO/PTT”). This connects to the associated ACE-RIU audio interface channel. PRC-117F (back) POWER +15VDC
NETWORK AUDIO/PTT
STATUS
ADVANCED SIMULATION TECHNOLOGY INC.
S/N:
XXXXXXXXXXXX
ADVANCED SIMULATION TECHNOLOGY inc. CHAN A
CHAN B
CHAN C
CHAN D
ACE-RIU
Figure 3: PRC-117 Panel connection to ACE-RIU
6
Copyright © 2012 Advanced Simulation Technology inc.
ASTi Simulated PRC-117 Panel Operator Guide (Ver. 1, Rev. C)
Audio / PTT Ancillary Connection There are two basic audio / PTT configuration options: a. Connect the handset directly to the panel’s AUDIO/DATA/FILL jack (J1). – or – b. Directly connect the audio / PTT ancillary to an ACE-RIU channel. To connect the handset, connect the handset cable to the panel's AUDIO/DATA/FILL jack (J1). Take note of the ACE-RIU MAC address and PRC-117 IP address as they are required for the software configuration which is covered in the Voisus Server Manual (DOC-05-VS-1).
Sonetronics model H-350/u
PRC-117F (front) J1
GPS J2 DATA
J3
Figure 4: Handset Connection
Copyright © 2012 Advanced Simulation Technology inc.
7
ASTi Simulated PRC-117 Panel Operator Guide (Ver. 1, Rev. C)
Follow the steps below for connecting the audio/PTT ancillaries to an ACE-RIU channel. 1. Connect the DB-9 cable to the appropriate ACE-RIU channel. 2. Connect the headset/mic and PTT box to the cable. This example depicts a common configuration: a professional series headset with mic and push-to-talk (PTT) box. The ACE-RIU can accommodate many other configurations.
HEADSET
PTT
PTT
VOL
AIU/RIU
ADVANCED SIMULATION TECHNOLOGY inc. CHAN A
CHAN B
CHAN C
CHAN D
ACE-RIU
Figure 5: Headset and PTT Connection
8
Copyright © 2012 Advanced Simulation Technology inc.
ASTi Simulated PRC-117 Panel Operator Guide (Ver. 1, Rev. C)
5.0. PRC-117 PANEL Panel Configuration Mode
Press and Hold
The PRC-117 panel must be in configuration mode for initial panel setup. To view the PRC-117 panel configuration menu set the function knob to the OFF mode. Then press and hold the arrow keys for approximately three (3) seconds and wait for the main mode screen to appear. When setting up the panel you must configure the IP address, locate the device name, and implement the discovery mode.
OFF position
MAIN MENU 1. SELF TEST SELF TEST MODE 2. CONFIG PANEL IP DISCOVERY ETHER ADDR 3. STATUS LINK STATUS FIRMWARE VERSION 4. NAME DISPLAYS PANEL NAME
In Menu Mode use the keypad to navigate through the menu screens. The CLR button will exit the current screen and return to the previous level.
MENU MODE 1. SELF TEST
3. STATUS
2. CONFIG
4. NAME
PRESS CLR TO EXIT
Copyright © 2012 Advanced Simulation Technology inc.
9
ASTi Simulated PRC-117 Panel Operator Guide (Ver. 1, Rev. C)
Configuration Mode Select “Config” from the main menu to set the IP address and Ether (MAC) address. In Discovery Mode the panel sends packets out to become recognized by the Voisus Server(s) on the network.
CONFIGURATION MODE 1. PANEL IP
3. ETHER ADDR
2. DISCOVERY PRESS CLR TO EXIT
Self Test Mode When running the self test the screen will flash until a button is pressed. Press a number button or change the function knob selection to ensure the panel is working properly.
Self Test 1
PRESS CLR TO EXIT Self Test 2 SELF TEST MODE KEY 2
KNOB PT
PRESS CLR TO EXIT
10
Copyright © 2012 Advanced Simulation Technology inc.
ASTi Simulated PRC-117 Panel Operator Guide (Ver. 1, Rev. C)
Status Mode The link status displays the state of the ethernet connection.You can also view the panel’s firmware version.
STATUS LINK STATUS: OFF FW VERSION :2.02 PRESS CLR TO EXIT Name Mode View the panel name. The panel name is configured in RMS under the Facility page.
NAME PRC-117F_OO_A1_B4
PRESS CLR TO EXIT
Copyright © 2012 Advanced Simulation Technology inc.
11
ASTi Simulated PRC-117 Panel Operator Guide (Ver. 1, Rev. C)
Panel Operation The operation of the simulated PRC-117 panel is based on the AN/PRC-117F(V)(C) Manpack Radio. The panel incorporates the following controls. Note that not all of the front panel controls and jacks are operational. • Backlight Display • Volume Controls • Plain text (PT) operation • Cipher text (CT) operation • SINCGARS operation • HAVEQUICK operation Operational Mode
Battery Meter Receive (R) Indicator Net Number and Name Net Type
R BAT
PT
NORM
Receive Signal
01 NET1 LOS
TYPE
VOC ADF
ADF Connector Mode
12
Plain or Cipher Text Operation
OFF
DATA
Data Port Mode
FM
MODE
AM or FM Mode
NOIS SQL
Squelch Setting
Copyright © 2012 Advanced Simulation Technology inc.
ASTi Simulated PRC-117 Panel Operator Guide (Ver. 1, Rev. C)
Backlight Display To configure the screen’s backlight and contrast the function switch must be in the PT or CT position. Press the LT key to view the backlight menu. • Light Operation: Use the up/down arrow keys to highlight Momentary, On or Off. Press Enter to make a selection. • Light Intensity: Use the left/right arrow keys to adjust the light intensity. Press Enter to make a selection. • Contrast: Use the left/right arrow keys to adjust the contrast. Press Enter to make a selection.
BACKLIGHT MENU 2 DEF LT
LIGHT OPERATION MOMENTARY ON OFF LIGHT INTENSITY
CONTRAST
Copyright © 2012 Advanced Simulation Technology inc.
13
ASTi Simulated PRC-117 Panel Operator Guide (Ver. 1, Rev. C)
Volume Display To configure the volume the function switch must be in the PT or CT position. Press the VOL+ or VOL- to view the Volume meter. Then adjust using the volume button.
+
When the Volume button is pressed the battery meter changes to Volume meter.
VOL
-
Volume Meter
R VOL
PT
NORM
01 NET1 LOS
TYPE
14
VOC ADF
OFF
DATA
FM
MODE
NOIS SQL
Copyright © 2012 Advanced Simulation Technology inc.
ASTi Simulated PRC-117 Panel Operator Guide (Ver. 1, Rev. C)
Plain Text Mode To use Plain Text operation the function switch must be in the PT position. Press Pre+ or Pre- to scroll through the net names and numbers as they are configured in the comm plan. When you reach the top or bottom of the net list you will hear a double-beep.
+
Press the PRE button to scroll through the Net Numbers and Names
PRE
-
Plain Text Operation
R BAT Net Number and Name
PT
NORM
01 NET1 LOS
VOC
TYPE
ADF
OFF
FM
DATA
NOIS
MODE
SQL
FM or AM mode depending on comm plan
If the radio is receiving the R will display in the left corner and the signal strength meter will reflect what is coming in from the transceiver. Receive (R) Indicator
R BAT
PT
NORM
Receive Signal
01 NET1 LOS
TYPE
VOC ADF
Copyright © 2012 Advanced Simulation Technology inc.
OFF
DATA
FM
MODE
NOIS SQL
15
ASTi Simulated PRC-117 Panel Operator Guide (Ver. 1, Rev. C)
Press the 0 key to view the radio sub-menu. 0
Press the 0 key to display the radio sub-menu.
R BAT Receive and Transmit Frequency Range 30.00000 MHZ - 511.99999 MHZ
PT
NORM
R: 030.00000 T: 030.00000 FREQUENCY
LOS 16.0 RATE
When the operator transmits on the radio the display changes to a “T” in the upper left corner. The signal strength bar becomes the TX power level bar. Transmit (T) Indicator
T BAT
R: 030.00000 T: 030.00000 FREQUENCY
16
PT
NORM LOS 16.0
Transmit Power Out Meter
RATE
Copyright © 2012 Advanced Simulation Technology inc.
ASTi Simulated PRC-117 Panel Operator Guide (Ver. 1, Rev. C)
Cipher Text Mode To use Cipher Text operation the function switch must be in the CT position. Cipher text mode displays the radio encryption details. The display will show VINSON, TEKxx, and CT. The TEKxx value is dependent on the TEK value chosen for that channel as defined in the Comm Plan, if a value is not assigned during radio setup then it is TEK01. These values are displayed in the same position on the main menu and when 0 is pressed for the sub-menu.
Crypto Type
R BAT
NORM
Encryption Key Type and Number
VINSON TEK01 CT
R: 030.00000 T: 030.00000 FREQUENCY
Copyright © 2012 Advanced Simulation Technology inc.
Cypher Text Operation
LOS 16.0 RATE
17
ASTi Simulated PRC-117 Panel Operator Guide (Ver. 1, Rev. C)
SINCGARS Operation To use SINCGARS operation the function switch must be in the PT or CT position. SINCGARS operation displays the SINCGARS net and details. SINCGARS nets are configured in the Comm Plan. Press 0 to view the SINCGARS sub-menu.
R BAT
PT
NORM
05-SINCGARS VOC ADF
ADF Connector Mode
R BAT
HOPSET ID from Setup File
SNCGRS
HOP TYPE
Data Port Mode
0
Day and Time Indicator
OFF
DATA
MEMBER
Frequency Hopping Mode
CUE
Indicates Presence of Cueing Station
Press the 0 key to display the SINCGARS sub-menu.
PT
NORM HOP
17d 11:22:33 F294
30.00000
HOPSET
CUE FREQUENCY
OFF
LINE
CUE Frequency from Setup File
18
Copyright © 2012 Advanced Simulation Technology inc.
ASTi Simulated PRC-117 Panel Operator Guide (Ver. 1, Rev. C)
HAVE QUICK Operation To use HAVE QUICK operation the function switch must be in the PT or CT position. HAVE QUICK operation displays the HAVE QUICK net and details. HAVE QUICK nets are configured in the Comm Plan. Press 0 to view the HAVE QUICK sub-menu.
R BAT HAVE QUICK Net
PT
NORM
06-HAVEQUICK VOC ADF
OFF
DATA
HVQUIK
HOP TYPE
OFF
Indicates Squelch
SQL ERR
Frequency Hopping Mode
0
Press the 0 key to display the HAVE QUICK sub-menu.
R BAT Time of Day Indicator HAVE QUICK Net Indicator
PT
NORM HOP
11:22:33 A 00.000 HQ NET NUM
05
DOM
HAVE QUICK Day of the Month
Copyright © 2012 Advanced Simulation Technology inc.
19
ASTi Simulated PRC-117 Panel Operator Guide (Ver. 1, Rev. C)
6.0. PANEL TECHNICAL SPECIFICATIONS Size:
9.5" (W) by 3.188" (H) by 8.5" (D)
Weight:
6.5 lbs.
Power:
6-36 VDC via power connector, provided by ASTi power module, included
7.0. PHYSICAL INTERFACES ACE-RIU Audio / PTT This interface is designed for connection with ASTi's ACE-RIU. Connector Type: Female, 9 Conductor, DB-9 Pins
Signal
1
Digital Out + (Not Used)
2
Audio Out, High
3
Digital Input +
4
Audio In, High
5
Signal Ground
6
Digital Out – (Not Used)
7
Audio Out, Low
8
Digital In – (I/O Ground)
9
Audio In, Low
1 2 3 4 5
6 7 8 9
ACE-RIU AUDIO/PTT
20
Copyright © 2012 Advanced Simulation Technology inc.
ASTi Simulated PRC-117 Panel Operator Guide (Ver. 1, Rev. C)
AUDIO/DATA/FILL J1 The AUDIO/DATA/FILL jack provides an interface to the Sonetronics handset Model H-350/U. A separate cable is also needed to interconnect the panel’s ACE-RIU “Audio / PTT” jack to the ACE-RIU channel. IMPORTANT: The audio port of the PRC-117 panel is configured for connection to the specified handset ONLY. Connection to any other equipment may cause damage to the PRC-117 panel, the handset or the ACE-RIU. Connection to non-specified equipment is considered equipment misuse; damage occurring due to equipment misuse is not covered by the ASTi warranty. Pins
Signal
A
Ground
B
Speaker
C
PTT Input
D
Microphone
E
Shield
F
No Connection
A E
B F D
C
AUDIO/DATA/FILL
Copyright © 2012 Advanced Simulation Technology inc.
21
ASTi Simulated PRC-117 Panel Operator Guide (Ver. 1, Rev. C)
Power The power jack is designed for use with the provided 6-36 VDC power supply only. Connector Type: Switchcraft Locking Connector 712A power jack
22
Copyright © 2012 Advanced Simulation Technology inc.
ASTi Simulated PRC-117 Panel Operator Guide (Ver. 1, Rev. C)
8.0. FURTHER READING Refer to the following document for more PRC-117 radio operational information: AN/PRC-117F(V)(C) Manpack Radio Operation Manual Publication Number 10515-0109-4100, dated 7/05
Copyright © 2012 Advanced Simulation Technology inc.
23