Transcript
Single Meter Sockets With Safety Socket Bypass
Single Meter Sockets - With Safety Socket Bypass
Single Meter Sockets, With Safety Socket Bypass, 100 & 200 Amp . . . . . . . . . . . . . . . . . . . . 23 - 24 Single Meter Sockets, With Safety Socket Bypass, 100 Amp - 10K AIC . . . . . . . . . . . . . . . . 25 - 26 Meter Mains, With Safety Socket Bypass, 100 & 200 Amp - 22K-65K AIC . . . . . . . . . . . . . 27 - 28 Meter Mains, With Safety Socket Bypass, 100 Amp - Fusible Pullout . . . . . . . . . . . . . . . . . . 29 - 30 Meter Mains Load Center With Safety Socket Bypass, 100 Amp . . . . . . . . . . . . . . . . . . . . . . . . 31 - 32 Meter Mains Load Center With Safety Socket Bypass, 200 Amp - 10K AIC . . . . . . . . . . . . 33 - 34 Meter Mains Load Center With Safety Socket Bypass, 200 Amp - 22K-65K AIC . . . . . . 35 - 36 Meter Mains Load Center With Safety Socket Bypass, 200 Amp - Fused Pullout . . . . . 37 - 38 Meter Mains Load Center With Safety Socket Bypass, 200 Amp . . . . . . . . . . . . . . . . . . . . . . . . 39 - 40 Test Block Bypass - Metering Breaker Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 - 45 Test Block Bypass - Safety Socket Bypass Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Meter Mounting Equipment
22
Single Meter Sockets - With Safety Socket Bypass 100 & 200 Amp Application • Safety socket bypass (test block bypass) under separate cover • Receive ANSI C12.10 watthour meters • Surface mount Construction • Ring type • NEMA Type 3R • ANSI 61 gray E-coat finish • Aluminum snap ring included
117TB (closed)
Standards • UL 414 Listed • ANSI C12.7 • EUSERC 304 & 305
117TB (open)
Accessories • 5th Jaw Kit - 50371 • Bussed Gutters - see page 51 • AW Hubs
Single Meter Sockets With Safety Socket Bypass
Part/UPC Number
78205147005 78205147025 78205147030 78205159005 78205159025 78205159035
Part/UPC Number
78205147005 78205147025 78205147030 78205159005 78205159025 78205159035
Catalog Number
114 TB * 115 TB * 117 TB * 124 TB ** 125 TB ** 127 TB **
Catalog Number
114 TB * 115 TB * 117 TB * 124 TB ** 125 TB ** 127 TB **
Amp Rating
Jaws
Service Type
Access
Bypass
Line
Connections Load
Neutral
100 100 100 200 200 200
4 5 7 4 5 7
1Ø/3W 3Ø/3W 3Ø/4W 1Ø/3W 3Ø/3W 3Ø/4W
OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG
TB TB TB TB TB TB
#14 - 2/0 #14 - 2/0 #14 - 2/0 #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM
14 - 2/0 14 - 2/0 14 - 2/0 #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM
#14 - 1/0 #14 - 1/0 #14 - 1/0 1/0 - 250 MCM 1/0 - 250 MCM 1/0 - 250 MCM
Height
Overall Dimensions Width Depth
Top Provision
Knockout Layout
45/8” 45/8” 45/8” 6” 6” 6”
AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub
Fig. 1 Fig. 1 Fig. 1 Fig. 2 Fig. 2 Fig. 2
24” 24” 24” 30” 30” 30”
12” 12” 12” 14” 14” 14”
* 100 Amp units compliant with EUSERC 304 ** 200 Amp units compliant with EUSERC 305
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
23
Meter Mounting Equipment
Single Meter Sockets - With Safety Socket Bypass 100 & 200 Amp
Knockouts - Conduit Sizes
Style # 114 TB 115 TB 117 TB 124 TB 125 TB 127 TB
Suffixes 2A = 1⁄2" - 1⁄4" 4F = 2" - 11⁄2" - 11⁄4" - 1” 4G = 21⁄2" - 2” - 11⁄2" - 11⁄4" 3H = 3” - 21⁄2" - 2" Top Provision = See Chart
F - Flush Mount MS20 - Ring Protector MS28 - Barriers on both sides of test block SS - Stainless Steel
Knockout Layouts
Fig. 1
Fig. 2 Top Provision Single Meter Sockets With Safety Socket Bypass
Top Provision
4F 4G 2A
4G
2A
4F
4F
3H
both sides
4G
4F
3H
both sides
3H
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
Meter Mounting Equipment
24
Meter Mains - With Safety Socket Bypass 100 Amp - 10K AIC Application • Combination meter/main with safety socket (test block) bypass • Factory installed breaker • Receive ANSI C12.10 watthour meters • Surface mount Construction • Ring type • NEMA Type 3R • ANSI 61 gray E-coat finish • Aluminum snap ring included Standards • UL 67 Listed • ANSI C12.7 • EUSERC 305A
U214 MTB (open)
Accessories • 5th Jaw Kit - 50371 • Bussed Gutters - see page 51 • AW Hubs
214 MTB (closed) Single Meter Sockets With Safety Socket Bypass
Part/UPC Number
78205145022 78205145032 78205145052 78205145060 78205145072 78205145078 78205145012 78205145112 78205145142 78205145150 78205145152 78205145158
Catalog Number
214 MTB 214 MTB MS15 215 MTB 215 MTB MS15 217 MTB 217 MTB MS15 U214 MTB U214 MTB MS15 U215 MTB U215 MTB MS15 U217 MTB U217 MTB MS15
Amp Rating
Jaws
Service Type
Access
Voltage
Main Breaker AIC
100 100 100 100 100 100 100 100 100 100 100 100
4 4 5 5 7 7 4 4 5 5 7 7
1Ø/3W 1Ø/3W 3Ø/3W 3Ø/3W 3Ø/4W 3Ø/4W 1Ø/3W 1Ø/3W 3Ø/3W 3Ø/3W 3Ø/4W 3Ø/4W
OH OH OH OH OH OH OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG
120/240 240/480 240* 480* 120/240 & 120/208 277/480 120/240 240/480 240* 480* 120/240 & 120/208 277/480
10K 10K 10K 10K 10K 10K 10K 10K 10K 10K 10K 10K
Main
Bypass
(1) 100A, 2P (1) 100A, 2P (1) 100A, 3P (1) 100A, 3P (1) 100A, 3P (1) 100A, 3P (1) 100A, 2P (1) 100A, 2P (1) 100A, 3P (1) 100A, 3P (1) 100A, 3P (1) 100A, 2P
TB TB TB TB TB TB TB TB TB TB TB TB
* For a 208/120V, 1Ø/3W system, order a 4-jaw unit and a 5th jaw kit Part/UPC Number
78205145022 78205145032 78205145052 78205145060 78205145072 78205145078 78205145012 78205145112 78205145142 78205145150 78205145152 78205145158
Catalog Number
214 MTB 214 MTB MS15 215 MTB 215 MTB MS15 217 MTB 217 MTB MS15 U214 MTB U214 MTB MS15 U215 MTB U215 MTB MS15 U217 MTB U217 MTB MS15
Line
Connections Load
Neutral
Height
#14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0
MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB
#14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0
38” 38” 38” 38” 38” 38” 24” 24” 24” 24” 24” 24”
Overall Dimensions Width Depth
Top Provision
Knockout Layout
45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8”
AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub
Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2
12” 12” 12” 12” 12” 12” 18” 18” 18” 18” 18” 18”
MCB - Main Circuit Breaker
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
25
Meter Mounting Equipment
Meter Mains - With Safety Socket Bypass 100 Amp - 10K AIC
Knockouts - Conduit Sizes
Style #
Suffixes
(U) 214 MTB (U) 215 MTB (U) 217 MTB
1A = 1⁄2" 2A = 1⁄2" - 1⁄4" 4F = 2" - 11⁄2" - 11⁄4" - 1” 4G = 21⁄2" - 2” - 11⁄2" - 11⁄4" Top Provision = See Chart
MS15 - 480V Breaker MS43 - No Breaker Included SS - Stainless Steel
Knockout Layouts
Fig. 1 Top Provision
Top Provision
4F
4F
4G
4F 4F
2A
both sides
4G 4F
both sides
4F
4F
4F
1A
1A
4F
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
Meter Mounting Equipment
26
Single Meter Sockets With Safety Socket Bypass
Fig. 2
Meter Mains - With Safety Socket Bypass 100 & 200 Amp - 22K - 65K AIC Application • • • •
Combination meter/main with safety socket (test block) bypass Factory installed breaker Receive ANSI C12.10 watthour meters Surface mount
Construction • Ring type • NEMA Type 3R • ANSI 61 gray E-coat finish • Aluminum snap ring included
214 MTBH (open) Part/UPC Number
Single Meter Sockets With Safety Socket Bypass
78205145030 78205159300 78205145028 78205145058 78205159302 78205145056 78205145076 78205159304 78205145074 78205145110 78205159200 78205145108 78205145148 78205159202 78205145146 78205145156 78205159204 78205145154
Part/UPC Number
78205145030 78205159300 78205145028 78205145058 78205159302 78205145056 78205145076 78205159304 78205145074 78205145110 78205159200 78205145108 78205145148 78205159202 78205145146 78205145156 78205159204 78205145154
Standards • UL 67 Listed • ANSI C12.7 • EUSERC 305A
U214 MTBH (open)
Catalog Number
214 MTBH 214 MTBH MS15 214 MTBH MS45 215 MTBH 215 MTBH MS15 215 MTBH MS45 217 MTBH 217 MTBH MS15 217 MTBH MS45 U214 MTBH U214 MTBH MS15 U214 MTBH MS45 U215 MTBH U215 MTBH MS15 U215 MTBH MS45 U217 MTBH U217 MTBH MS15 U217 MTBH MS45
Catalog Number
214 MTBH 214 MTBH MS15 214 MTBH MS45 215 MTBH 215 MTBH MS15 215 MTBH MS45 217 MTBH 217 MTBH MS15 217 MTBH MS45 U214 MTBH U214 MTBH MS15 U214 MTBH MS45 U215 MTBH U215 MTBH MS15 U215 MTBH MS45 U217 MTBH U217 MTBH MS15 U217 MTBH MS45
Amp Rating
Jaws
Service Type
Access
100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100
4 4 4 5 5 5 7 7 7 4 4 4 5 5 5 7 7 7
1Ø/3W 1Ø/3W 1Ø/3W 3Ø/3W 3Ø/3W 3Ø/3W 3Ø/4W 3Ø/4W 3Ø/4W 1Ø/3W 1Ø/3W 1Ø/3W 3Ø/3W 3Ø/3W 3Ø/3W 3Ø/4W 3Ø/4W 3Ø/4W
OH OH OH OH OH OH OH OH OH OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG
Accessories • 5th Jaw Kit - 50371 • Bussed Gutters - see page 51 • AW Hubs Voltage
Main Breaker AIC
Main
Bypass
120/240 65K (1) 100A, 2P TB 240/480 42K (1) 100A, 2P TB 120/240 22K (1) 100A, 2P TB 240* 65K (1) 100A, 3P TB 480* 42K (1) 100A, 3P TB 240* 22K (1) 100A, 3P TB 120/240 & 120/208 65K (1) 100A, 3P TB 480/277 42K (1) 100A, 3P TB 120/240 & 120/208 22K (1) 100A, 3P TB 120/240 65K (1) 100A, 2P TB 240/480 42K (1) 100A, 2P TB 120/240 22K (1) 100A, 2P TB 240* 65K (1) 100A, 3P TB 480* 42K (1) 100A, 3P TB 240* 22K (1) 100A, 3P TB 120/240 & 120/208 65K (1) 100A, 3P TB 480/277 42K (1) 100A, 3P TB 120/240 & 120/208 22K (1) 100A, 3P TB * For a 208/120V, 1Ø/3W system, order a 4-jaw unit and a 5th jaw kit
Line
Connections Load
Neutral
Height
#14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0
MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB
#14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0
38” 38” 38” 38” 38” 38” 38” 38” 38” 24” 24” 24” 24” 24” 24” 24” 24” 24”
Overall Dimensions Width Depth
Top Provision
Knockout Layout
45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8”
AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub
Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2
12” 12” 12” 12” 12” 12” 12” 12” 12” 18” 18” 18” 18” 18” 18” 18” 18” 18”
MCB - Main Circuit Breaker Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
27
Meter Mounting Equipment
Meter Mains - With Safety Socket Bypass 100 & 200 Amp - 22K - 65K AIC
Knockouts - Conduit Sizes
Style #
Suffixes
(U) 214 MTBH (U) 215 MTBH (U) 217 MTBH
1A = 1⁄2" 2A = 1⁄2" - 1⁄4" 4F = 2" - 11⁄2" - 11⁄4" - 1” 4G = 21⁄2" - 2” - 11⁄2" - 11⁄4" Top Provision = See Chart
MS15 - 480V Breaker MS43 - No Breaker Included MS45 - 22K AIC Rated Breaker SS - Stainless Steel
Knockout Layouts
Fig. 1 Top Provision
Top Provision
4F
4F
4G
4F 4F
2A
both sides
4G 4F
both sides
4F
4F
4F
1A
1A
4F
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
Meter Mounting Equipment
28
Single Meter Sockets With Safety Socket Bypass
Fig. 2
Meter Mains - With Safety Socket Bypass 100 Amp - Fusible Pullout Application • Combination meter/main with safety socket (test block) bypass • Factory installed fused pullout (“T” fuses included) • Receive ANSI C12.10 watthour meters • Surface mount Construction • Ring type • NEMA Type 3R • ANSI 61 gray E-coat finish • Aluminum snap ring included Standards • UL 67 Listed • ANSI C12.7 • EUSERC 305A
U214 MTBP (open)
Accessories • 5th Jaw Kit - 50371 • Bussed Gutters - see page 51 • AW Hubs
214 MTBP (open) Single Meter Sockets With Safety Socket Bypass
Part/UPC Number
78205148000 78205152000 78205148020 78205152010 78205148030 78205152020 78205148080 78205152060 78205148100 78205152070 78205148110 78205152100
Catalog Number
214 MTBP 214 MTBP MS15 215 MTBP 215 MTBP MS15 217 MTBP 217 MTBP MS15 U214 MTBP U214 MTBP MS15 U215 MTBP U215 MTBP MS15 U217 MTBP U217 MTBP MS15
Amp Rating
Jaws
Service Type
Access
Voltage
Main Breaker AIC
100 100 100 100 100 100 100 100 100 100 100 100
4 4 5 5 7 7 4 4 5 5 7 7
1Ø/3W 1Ø/3W 3Ø/3W 3Ø/3W 3Ø/4W 3Ø/4W 1Ø/2W 1Ø/2W 3Ø/3W 3Ø/3W 3Ø/4W 3Ø/4W
OH OH OH OH OH OH OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG
120/240 240/480 240* 480* 120/240 & 120/208 480/277 120/240 240/480 240* 480* 120/240 & 120/208 480/277
200K 200K 200K 200K 200K 200K 200K 200K 200K 200K 200K 200K
Main
Bypass
(1) 100A, 2P (1) 100A, 2P (1) 100A, 3P (1) 100A, 3P (1) 100A, 3P (1) 100A, 3P (1) 100A, 2P (1) 100A, 2P (1) 100A, 3P (1) 100A, 3P (1) 100A, 3P (1) 100A, 3P
TB TB TB TB TB TB TB TB TB TB TB TB
* For a 208/120V, 1Ø/3W system, order a 4-jaw unit and a 5th jaw kit Part/UPC Number
78205148000 78205152000 78205148020 78205152010 78205148030 78205152020 78205148080 78205152060 78205148100 78205152070 78205148110 78205152100
Catalog Number
214 MTBP 214 MTBP MS15 215 MTBP 215 MTBP MS15 217 MTBP 217 MTBP MS15 U214 MTBP U214 MTBP MS15 U215 MTBP U215 MTBP MS15 U217 MTBP U217 MTBP MS15
Line
Connections Load
Neutral
Height
#14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0
Main Fuse Main Fuse Main Fuse Main Fuse Main Fuse Main Fuse Main Fuse Main Fuse Main Fuse Main Fuse Main Fuse Main Fuse
#14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0
38” 38” 38” 38” 38” 38” 24” 24” 24” 24” 24” 24”
Overall Dimensions Width Depth
Top Provision
Knockout Layout
45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8”
AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub
Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2
12” 12” 12” 12” 12” 12” 18” 18” 18” 18” 18” 18”
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
29
Meter Mounting Equipment
Meter Mains - With Safety Socket Bypass 100 Amp - Fusible Pullout
Knockouts - Conduit Sizes
Style #
Suffixes
(U) 214 MTBP (U) 215 MTBP (U) 217 MTBP
1A = 1⁄2" 2A = 1⁄2" - 1⁄4" 4F = 2" - 11⁄2" - 11⁄4" - 1” 4G = 21⁄2" - 2” - 11⁄2" - 11⁄4" Top Provision = See Chart
P - Pullout Fuse MS15 - 480V Breaker MS43 - No Breaker Included SS - Stainless Steel
Knockout Layouts
Fig. 1 Top Provision
Top Provision
4F
4F
4G
4F 4F
2A
both sides
4G 4F
both sides
4F
4F
4F
1A
1A
4F
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
Meter Mounting Equipment
30
Single Meter Sockets With Safety Socket Bypass
Fig. 2
Meter Main Load Center - With Safety Socket Bypass 100 Amp Application • Combination meter/main/loadcenter with safety socket (test block) bypass • Factory installed breakers / fused pullout (“T” fuses included) • Receive ANSI C12.10 watthour meters • Surface mount Construction • Ring type • NEMA Type 3R • ANSI 61 gray E-coat finish • Aluminum snap ring included Standards • UL 67 Listed • ANSI C12.7
U214 MTBL (closed)
Accessories • 5th Jaw Kit - 50371 • Bussed Gutters - see page 51 • AW Hubs
Single Meter Sockets With Safety Socket Bypass
U214 MTBL (open)
Part/UPC Number
Catalog Number
Amp Rating
Jaws
Service Type
Access
78205170126 78205170128 78205170130 78205170132 78205170134 78205170136
U214 MTBL U214 MTBPL U215 MTBL U215 MTBPL U217 MTBL U217 MTBPL
100 100 100 100 100 100
4 4 5 5 7 7
1Ø/3W 1Ø/3W 3Ø/4W 3Ø/4W 3Ø/4W 3Ø/4W
OH/UG 120/240 OH/UG 120/240 OH/UG 240* OH/UG 240* OH/UG 120/240 & 120/208 OH/UG 120/208
Voltage
Main Breaker AIC
10K 10K 10K 10K 10K 10K
Main
Loadcenter
Bypass
(1) 100A, 2P (1) 100A, 2P (1) 100A, 3P (1) 100A, 3P (1) 100A, 3P (1) 100A, 3P
12/24 12/24 18/36 18/36 18/36 18/36
TB TB TB TB TB TB
* For a 208/120V, 1Ø/3W system, order a 4-jaw unit and a 5th jaw kit
Part/UPC Number
Catalog Number
Line
Connections Load
Neutral
Height
78205170126 78205170128 78205170130 78205170132 78205170134 78205170136
U214 MTBL U214 MTBPL U215 MTBL U215 MTBPL U217 MTBL U217 MTBPL
#14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0
MCB Main Fuse MCB Main Fuse MCB Main Fuse
#14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0
24” 24” 24” 28” 24” 28”
Overall Dimensions Width Depth
Top Provision
Knockout Layout
45/8” 45/8” 45/8” 45/8” 45/8” 45/8”
AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub
Fig. 1 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2
20” 25” 25” 25” 25” 25”
MCB - Main Circuit Breaker
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
31
Meter Mounting Equipment
Meter Main Load Center - With Safety Socket Bypass 100 Amp
Knockouts - Conduit Sizes
Style #
Suffixes
(U) 214 MTBL (U) 214 MTBPL (U) 215 MTBL (U) 215 MTBPL (U) 217 MTBL (U) 217 MTBPL
1A = 1⁄2" 2B = 3⁄4" - 1⁄2" 4D = 11⁄4" - 1” - 3⁄4" - 1⁄2" 4E = 11⁄2" - 11⁄4" - 1” - 3⁄4" 4F = 2" - 11⁄2" - 11⁄4" - 1” 4G = 21⁄2" - 2” - 11⁄2" - 11⁄4" Top Provision = See Chart
P - Pullout Fuse MS43 - No Breaker Included SS - Stainless Steel
Knockout Layouts Fig. 1
Fig. 2 Top Provision Single Meter Sockets With Safety Socket Bypass
Top Provision
1A (6)
4E
4E
1A (4)
1A
4G
4E
1A
2B
4G
(2)
1A
2B
4D
1A
(5)
1A (4)
2B 4F
(3)
4F
4E
4E 2B
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
Meter Mounting Equipment
32
Meter Main Load Center - With Safety Socket Bypass 200 Amp - 10K AIC Application • Combination meter/main with safety socket (test block) bypass • Factory installed breaker • Receive ANSI C12.10 watthour meters • Surface mount Construction • Ring type • NEMA Type 3R • ANSI 61 gray E-coat finish • Aluminum snap ring included Standards • UL 67 Listed • ANSI C12.7 • EUSERC 305A Accessories • 5th Jaw Kit - 50371 • Bussed Gutters - see page 51 • AW Hubs
U224 MTB (open)
224 MTB (open) Single Meter Sockets With Safety Socket Bypass
Part/UPC Number
Catalog Number
Amp Rating
Jaws
Service Type
Access
Voltage
Main Breaker AIC
78205159065 78205159085 78205159095 78205170141 78205159125 78205159145 78205159155
224 MTB 225 MTB 227 MTB U224 M11TB U224 MTB U225 MTB U227 MTB
200 200 200 200 200 200 200
4 5 7 4 4 5 7
1Ø/3W 3Ø/3W 3Ø/4W 1Ø/3W 1Ø/3W 3Ø/3W 3Ø/4W
OH OH OH OH/UG OH/UG OH/UG OH/UG
120/240 240* 120/240 & 120/208 120/240 120/240 240* 120/240 & 120/208
10K 10K 10K 10K 10K 10K 10K
Main
Bypass
(1) 200A, 2P (1) 200A, 3P (1) 200A, 3P (2) 100A, 2P (1) 200A, 2P (1) 200A, 3P (1) 200A, 3P
TB TB TB TB TB TB TB
* For a 208/120V, 1Ø/3W system, order a 4-jaw unit and a 5th jaw kit Part/UPC Number
Catalog Number
Line
Connections Load
Neutral
Height
78205159065 78205159085 78205159095 78205170141 78205159125 78205159145 78205159155
224 MTB 225 MTB 227 MTB U224 M11TB U224 MTB U225 MTB U227 MTB
#6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM
MCB MCB MCB MCB MCB MCB MCB
#6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM
48” 48” 48” 30” 30” 30” 30”
Overall Dimensions Width Depth
14” 14” 14” 22” 22” 22” 22”
6” 6” 6” 6” 6” 6” 6”
Top Provision
Knockout Layout
AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub
Fig. 1 Fig. 1 Fig. 1 Fig. 3 Fig. 2 Fig. 2 Fig. 2
MCB - Main Circuit Breaker
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
33
Meter Mounting Equipment
Meter Main Load Center - With Safety Socket Bypass 200 Amp - 10K AIC Knockouts - Conduit Sizes
Style #
Suffixes
(U) 224 MTB (U) 224 M11TB (U) 225 MTB (U) 227 MTB
1A = 1⁄2" 2A = 1⁄2" - 1⁄4" 4E = 11⁄2" - 11⁄4" - 1” - 3⁄4" 4G = 21⁄2" - 2” - 11⁄2" - 11⁄4" 2H = 3" - 21⁄2" 3H = 3” - 21⁄2" - 2" 4H = 3” - 21⁄2" - 2” - 11⁄2" Top Provision = See Chart
MS43 - No Breaker Included SS - Stainless Steel
Knockout Layouts Fig. 1
Fig. 2 Top Provision
Single Meter Sockets With Safety Socket Bypass
Top Provision
4G 4G 2H 4G
3H
both sides
4G
both sides
3H
2A
3H
1A
2H
2H
1A
4G
Fig. 3 Top Provision
4G
4E
4G
4G
both sides
1A
1A
4H
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
Meter Mounting Equipment
34
Meter Main - With Safety Socket Bypass 200 Amp - 22K-65K AIC Application • • • •
Combination meter/main with safety socket (test block) bypass Factory installed breaker Receive ANSI C12.10 watthour meters Surface mount
Construction • Ring type • NEMA Type 3R • ANSI 61 gray E-coat finish • Aluminum snap ring included Standards • UL 67 Listed • ANSI C12.7 • EUSERC 305A
U224 MTBH (open) 224 MTBH (open) Part/UPC Number
Single Meter Sockets With Safety Socket Bypass
78205159081 78205159306 78205159079 78205159091 78205159308 78205159089 78205159159 78205159310 78205159097 78205159141 78205159206 78205159139 78205159151 78205159208 78205159149 78205159159 78205159210 78205159157 Part/UPC Number
78205159081 78205159306 78205159079 78205159091 78205159308 78205159089 78205159159 78205159310 78205159097 78205159141 78205159206 78205159139 78205159151 78205159208 78205159149 78205159159 78205159210 78205159157
Catalog Number
224 MTBH 224 MTBH MS15 224 MTBH MS45 225 MTBH 225 MTBH MS15 225 MTBH MS45 227 MTBH 227 MTBH MS15 227 MTBH MS45 U224 MTBH U224 MTBH MS15 U224 MTBH MS45 U225 MTBH U225 MTBH MS15 U225 MTBH MS45 U227 MTBH U227 MTBH MS15 U227 MTBH MS45 Catalog Number
224 MTBH 224 MTBH MS15 224 MTBH MS45 225 MTBH 225 MTBH MS15 225 MTBH MS45 227 MTBH 227 MTBH MS15 227 MTBH MS45 U224 MTBH U224 MTBH MS15 U224 MTBH MS45 U225 MTBH U225 MTBH MS15 U225 MTBH MS45 U227 MTBH U227 MTBH MS15 U227 MTBH MS45
Amp Rating
Jaws
Service Type
200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200
4 4 4 5 5 5 7 7 7 4 4 4 5 5 5 7 7 7
1Ø/3W 1Ø/3W 1Ø/3W 3Ø/3W 3Ø/3W 3Ø/3W 3Ø/4W 3Ø/4W 3Ø/4W 1Ø/3W 1Ø/3W 1Ø/3W 3Ø/3W 3Ø/3W 3Ø/3W 3Ø/4W 3Ø/4W 3Ø/4W
Access
Accessories • 5th Jaw Kit - 50371 • Bussed Gutters - see page 51 • AW Hubs Voltage
Main Breaker AIC
Main
Bypass
OH 120/240 42K (1) 200A, 2P TB OH 240/480 22K (1) 200A, 2P TB OH 120/240 22K (1) 200A, 2P TB OH 240* 42K (1) 200A, 3P TB OH 480* 22K (1) 200A, 3P TB OH 240* 22K (1) 200A, 3P TB OH 120/240 & 120/208 42K (1) 200A, 3P TB OH 480/277 22K (1) 200A, 3P TB OH 120/240 & 120/208 22K (1) 200A, 3P TB OH/UG 120/240 42K (1) 200A, 2P TB OH/UG 240/480 22K (1) 200A, 2P TB OH/UG 120/240 22K (1) 200A, 2P TB OH/UG 240* 42K (1) 200A, 3P TB OH/UG 480* 22K (1) 200A, 3P TB OH/UG 240* 22K (1) 200A, 3P TB OH/UG 120/240 & 120/208 42K (1) 200A, 3P TB OH/UG 480/277 22K (1) 200A, 3P TB OH/UG 120/240 & 120/208 22K (1) 200A, 3P TB * For a 208/120V, 1Ø/3W system, order a 4-jaw unit and a 5th jaw kit
Line
Connections Load
Neutral
Height
#6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM
MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB
#6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM
48” 48” 48” 48” 48” 48” 48” 48” 48” 30” 30” 30” 30” 30” 30” 30” 30” 30”
Overall Dimensions Width Depth
14” 14” 14” 14” 14” 14” 14” 14” 14” 22” 22” 22” 22” 22” 22” 22” 22” 22”
6” 6” 6” 6” 6” 6” 6” 6” 6” 6” 6” 6” 6” 6” 6” 6” 6” 6”
Top Provision
Knockout Layout
AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub
Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2
MCB - Main Circuit Breaker Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
35
Meter Mounting Equipment
Meter Main - With Safety Socket Bypass 200 Amp - 22K-65K AIC
Knockouts - Conduit Sizes
Style #
Suffixes
(U) 224 MTBH (U) 225 MTBH (U) 227 MTBH
1A = 1⁄2" 2A = 1⁄2" - 1⁄4" 4G = 21⁄2" - 2” - 11⁄2" - 11⁄4" 2H = 3" - 21⁄2" 3H = 3” - 21⁄2" - 2" Top Provision = See Chart
MS15 - 480V Breaker MS43 - No Breaker Included MS45 - 22K AIC Rated Breaker SS - Stainless Steel
Knockout Layouts Fig. 1
Fig. 2 Top Provision Single Meter Sockets With Safety Socket Bypass
Top Provision
4G 4G 2H 4G
3H
both sides
4G
both sides
3H
2A
3H
2H
1A
2H
1A
4G
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
Meter Mounting Equipment
36
Meter Main - With Safety Socket Bypass 200 Amp - Fusible Pullout Application • • • •
Combination meter/main with safety socket (test block) bypass Factory installed breaker Receive ANSI C12.10 watthour meters Surface mount
Construction • Ring type • NEMA Type 3R • ANSI 61 gray E-coat finish • Aluminum snap ring included Standards • UL 67 Listed • ANSI C12.7 • EUSERC 305A
224 MTBP (open)
Single Meter Sockets With Safety Socket Bypass
Part/UPC Number
78205161000 78205163000 78205161080 78205107971 78205161100 78205163020 78205162000 78205163040 78205162080 78205163050 78205162100 78205163060
Accessories • 5th Jaw Kit - 50371 • Bussed Gutters - see page 51 • AW Hubs
U224 MTBP (open)
Catalog Number
224 MTBP 224 MTBP MS15 225 MTBP 225 MTBP MS15 227 MTBP 227 MTBP MS15 U224 MTBP U224 MTBP MS15 U225 MTBP U225 MTBP MS15 U227 MTBP U227 MTBP MS15
Amp Rating
Jaws
Service Type
Access
Voltage
Main Breaker AIC
200 200 200 200 200 200 200 200 200 200 200 200
4 4 5 5 7 7 4 4 5 5 7 7
1Ø/3W 1Ø/3W 3Ø/3W 3Ø/3W 3Ø/4W 3Ø/4W 1Ø/3W 1Ø/3W 3Ø/3W 3Ø/3W 3Ø/4W 3Ø/4W
OH OH OH OH OH OH OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG
120/240 240/480 240* 480* 120/240 & 120/208 480/277 120/240 240/480 240* 480* 120/240 & 120/208 480/277
200K 200K 200K 200K 200K 200K 200K 200K 200K 200K 200K 200K
Main
Bypass
(1) 200A, 2P (1) 200A, 2P (1) 200A, 3P (1) 200A, 3P (1) 200A, 3P (1) 200A, 3P (1) 200A, 2P (1) 200A, 2P (1) 200A, 3P (1) 200A, 3P (1) 200A, 3P (1) 200A, 3P
TB TB TB TB TB TB TB TB TB TB TB TB
* For a 208/120V, 1Ø/3W system, order a 4-jaw unit and a 5th jaw kit Part/UPC Number
78205161000 78205163000 78205161080 78205107971 78205161100 78205163020 78205162000 78205163040 78205162080 78205163050 78205162100 78205163060
Catalog Number
224 MTBP 224 MTBP MS15 225 MTBP 225 MTBP MS15 227 MTBP 227 MTBP MS15 U224 MTBP U224 MTBP MS15 U225 MTBP U225 MTBP MS15 U227 MTBP U227 MTBP MS15
Line
Connections Load
Neutral
Height
#6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM
MCB MCB MCB MCB MCB MCB Main Fuse Main Fuse Main Fuse Main Fuse Main Fuse Main Fuse
#6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM
48” 48” 48” 48” 48” 48” 30” 30” 30” 30” 30” 30”
Overall Dimensions Width Depth
14” 14” 14” 14” 14” 14” 22” 22” 22” 22” 22” 22”
6” 6” 6” 6” 6” 6” 6” 6” 6” 6” 6” 6”
Top Provision
Knockout Layout
AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub
Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2
MCB - Main Circuit Breaker
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
37
Meter Mounting Equipment
Meter Main - With Safety Socket Bypass 200 Amp - Fusible Pullout
Knockouts - Conduit Sizes
Style #
Suffixes
(U) 224 MTBP (U) 225 MTBP (U) 227 MTBP
1A = 1⁄2" 2A = 1⁄2" - 1⁄4" 4G = 21⁄2" - 2” - 11⁄2" - 11⁄4" 2H = 3" - 21⁄2" 3H = 3” - 21⁄2" - 2" Top Provision = See Chart
P - Pullout Fuse MS15 - 480V Breaker MS43 - No Breaker Included SS - Stainless Steel
Knockout Layouts Fig. 1
Fig. 2 Top Provision Single Meter Sockets With Safety Socket Bypass
Top Provision
4G 4G 2H 4G
3H
both sides
4G
both sides
3H
2A
3H
2H
1A
2H
1A
4G
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
Meter Mounting Equipment
38
Meter Main Loadcenter - With Safety Socket Bypass 200 Amp Application • Combination meter/main/loadcenter with safety socket (test block) bypass • Factory installed breakers / fusible pullout (“T” fuses included) • Receive ANSI C12.10 watthour meters • Surface mount Construction • Ring type • NEMA Type 3R • ANSI 61 gray E-coat finish • Aluminum snap ring included
U224 MTBL (closed)
Standards • UL 67 Listed • ANSI C12.7 • EUSERC 305A
U224 MTBL (open)
Single Meter Sockets With Safety Socket Bypass
Part/UPC Number
Catalog Number
Amp Rating
Jaws
Service Type
Access
Voltage
Main Breaker AIC
78205170138 78205170140 78205170142 78205170144 78205170146 78205170148
U224 MTBL U224 MTBPL U225 MTBL U225 MTBPL U227 MTBL U227 MTBPL
200 200 200 200 200 200
4 4 5 5 7 7
1Ø/3W 1Ø/3W 3Ø/3W 3Ø/3W 3Ø/4W 3Ø/4W
OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG
120/240 120/240 240* 240* 120/240 & 120/208 120/240 & 120/208
10K 100K 10K 100K 10K 100K
Main
Loadcenter
Bypass
(1) 200A, 2P (1) 200A, 2P (1) 200A, 3P (1) 200A, 3P (1) 200A, 3P (1) 200A, 3P
20/40 20/40 24/42 24/42 24/42 24/42
TB TB TB TB TB TB
* For a 208/120V, 1Ø/3W system, order a 4-jaw unit and a 5th jaw kit
Part/UPC Number
Catalog Number
Line
Connections Load
Neutral
Height
78205170138 78205170140 78205170142 78205170144 78205170146 78205170148
U224 MTBL U224 MTBPL U225 MTBL U225 MTBPL U227 MTBL U227 MTBPL
#6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM
MCB Main Fuse MCB Main Fuse MCB Main Fuse
#6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM
30” 30” 32” 32” 32” 32”
Overall Dimensions Width Depth
27” 27” 27” 27” 27” 27”
6” 6” 6” 6” 6” 6”
Top Provision
Knockout Layout
AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub
Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1
MCB - Main Circuit Breaker
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
39
Meter Mounting Equipment
Meter Main Loadcenter - With Safety Socket Bypass 200 Amp
Knockouts - Conduit Sizes
Style #
Suffixes
(U) 224 MTBL (U) 224 MTBPL (U) 225 MTBL (U) 225 MTBPL (U) 227 MTBL (U) 227 MTBPL
1A = 1⁄2" 2B = 3⁄4" - 1⁄2" 4D = 11⁄4" - 1” - 3⁄4" - 1⁄2" 4E = 11⁄2" - 11⁄4" - 1” - 3⁄4" 2H = 3" - 21⁄2" Top Provision = See Chart
P - Pullout Fuse MS43 - No Breaker Included SS - Stainless Steel
Knockout Layouts Fig. 1
Single Meter Sockets With Safety Socket Bypass
Top Provision
1A 2B
(6)
4E
(4)
2H
1A (9)
1A
4E 2B
4D
2B
4E
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
Meter Mounting Equipment
40
Test Block Bypass - Metering Breaker Data Main Breaker Data Catalog Number
Single Meter Sockets With Safety Socket Bypass
B-Line Breaker #
ITE Breaker #
Ampacity
Voltage
# of Poles
AIC
25458P 25460P 25460P 25464P 25466P 25466P 25470P 25472P 25472P 25534N 25536N 25536N 25544N 25546N 25546N 25458P 25460P 25460P 25508K 25510K 25510K 25512K 25514K 25514K 25516K 25518K 25518K 25552J 25554J 25554J
Q2100 Q3100 Q3100 Q2100H Q3100H Q3100H Q2100HH Q3100HH Q3100HH ED42B100 ED43B100 ED43B100 HED42B100 HED43B100 HED43B100 Q2100 Q3100 Q3100 QJ22B200 QJ23B200 QJ23B200 QJH22B200H QJH23B200H QJH23B200H QJ22B200H QJ23B200H QJ23B200H FXD62B200 FXD63B200 FXD63B200
100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 200A 200A 200A 200A 200A 200A 200A 200A 200A 200A 200A 200A
240 240 240 240 240 240 240 240 240 480 480 480 480 480 480 240 240 240 240 240 240 240 240 240 240 240 240 480 480 480
2P 3P 3P 2P 3P 3P 2P 3P 3P 2P 3P 3P 2P 3P 3P 2P 3P 3P 2P 3P 3P 2P 3P 3P 2P 3P 3P 2P 3P 3P
10K 10K 10K 22K 22K 22K 42K 42K 42K 10K 10K 10K 42K 42K 42K 10K 10K 10K 10K 10K 10K 22K 22K 22K 42K 42K 42K 22K 22K 22K
B-Line Breaker #
Boltswitch Pullout #
Ampacity
Voltage
# of Poles
AIC
20404A 20404B 20404B 20404E 20404F 20404F 20404C 20404D 20404D 20404G 20404H 20404H
PT323-2P PT323 PT323 PT363-2P PT363 PT363 PT324-2P PT324 PT324 PT364-2P PT364 PT364
100A 100A 100A 100A 100A 100A 200A 200A 200A 200A 200A 200A
240 240 240 480 480 480 240 240 240 480 480 480
2P 3P 3P 2P 3P 3P 2P 3P 3P 2P 3P 3P
200K 200K 200K 200K 200K 200K 200K 200K 200K 200K 200K 200K
B-Line Breaker # 25050A 25051A 25051A 25052A 25053A 25053A
ITE Pullout # TFP223 TFP323 TFP323 TFP224 TFP324 TFP324
Ampacity
Voltage
AIC
100A 100A 100A 200A 200A 200A
240 240 240 240 240 240
# of Poles 2P 3P 3P 2P 3P 3P
U214MTB U215MTB U217MTB U214MTBHMS45 U215MTBHMS45 U217MTBHMS45 U214MTBH U215MTBH U217MTBH U214MTBMS15 U215MTBMS15 U217MTBMS15 U214MTBHMS15 U215MTBHMS15 U217MTBHMS15 U214MTBL U215MTBL U217MTBL U224MTB U225MTB U227MTB U224MTBHMS45 U225MTBHMS45 U227MTBHMS45 U224MTBH U225MTBH U227MTBH U224MTBHMS15 U225MTBHMS15 U227MTBHMS15
Main Pullout Data Catalog Number
U214MTBP U215MTBP U217MTBP U214MTBPMS15 U215MTBPMS15 U217MTBPMS15 U224MTBP U225MTBP U227MTBP U224MTBPMS15 U225MTBPMS15 U227MTBPMS15
Main Pullout Data Catalog Number U214MTBPL U215MTBPL U217MTBPL U224MTBPL U225MTBPL U227MTBPL
100K 100K 100K 100K 100K 100K
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
41
Meter Mounting Equipment
Test Block Bypass - Wiring Diagrams
N
L I N E
O
A
L O A D
L I N E
B
L O A D
N
L I N E
O
A
L O A D
L I N E
L O A D
L I N E
B
L O A D
L I N E
L O A D
B
A
O N
L I N E
A
L O A D
Catalog #
Catalog #
214MTB 214MTBHMS45 214MTBH 214MTBMS15 214MTBHMS15 224MTB 224MTBHMS45 224MTBH 224MTBMS15
214MTBP 214MTBPMS15 224MTBP 224MTBPMS15
U214MTB U214MTBMS15 U214MTBHMS15 U214MTBH U214MTBHMS45 U224MTB U224MTBH U224MTBHMS45
L I N E
L O A D
B
Single Meter Sockets With Safety Socket Bypass
Catalog #
N
L I N E
O
A
L O A D
L I N E
L O A D
B
L I N E
C
L O A D
N
L I N E
O
A
L O A D
L I N E
L O A D
B
L I N E
C
O N
Catalog #
Catalog #
Catalog #
U214MTBP U214MTBPMS15 U224MTBP U224MTBPMS15
215MTB 215MTBMS15 215MTBHMS15 215MTBH 215MTBHMS45 225MTB 225MTBH 225MTBHMS45
215MTBP 215MTBPMS15 225MTBP 225MTBPMS15
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
Meter Mounting Equipment
42
L O A D
Test Block Bypass - Wiring Diagrams
L I N E
A
L O A D
L I N E
B
L O A D
L I N E
L I N E
L O A D
C
L O A D
A
L I N E
L I N E
L O A D
B
L O A D
C
O
O
N
N
N
L I N E
O
A
L I N E
L O A D
L I N E
L O A D
B
C
Single Meter Sockets With Safety Socket Bypass
Catalog #
Catalog #
Catalog #
U215MTB U215MTBMS15 U215MTBHMS15 U215MTBH U215MTBHMS45 U225MTB U225MTBH U225MTBHMS45 U225MTBHMS15
U215MTBP U214MTBPMS15 U225MTBP U225MTBPMS15
U217MTB U217MTBMS15 U217MTBHMS15 U217MTBH U217MTBHMS45 U227MTB U227MTBH U227MTBHMS45 U227MTBHMS15
N
L I N E
O
A
L O A D
L I N E
L O A D
L I N E
B
C
L O A D
L I N E
A
L O A D
L I N E
B
L O A D
L I N E
L O A D
L I N E
C
A
L O A D
L I N E
B
L O A D
L I N E
L O A D
L O A D
C
O
O
N
N
Catalog #
Catalog #
Catalog #
217MTBP 217MTBPMS15 227MTBP 227MTBPMS15
U217MTB U217MTBMS15 U217MTBHMS15 U217MTBH U217MTBHMS45 U227MTB U227MTBMS15 U227MTBH U227MTBHMS45
U217MTBP U217MTBPMS15 U227MTBP U227MTBPMS15
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
43
Meter Mounting Equipment
Test Block Bypass - Wiring Diagrams Ground Bar Provision Ground Bar Provision
Main Disconnect
Main Disconnect
B B
A
N
Panel
N
Panel
Catalog #
Catalog #
U214MTBL
U214MTBPL
Ground Bar Provision
Ground Bar Provision Main Disconnect
Main Disconnect
A A
B
B
C
C
N N Panel
Panel
Catalog #
Catalog #
U215MTBL
U215MTBPL
Main Disconnect
Ground Bar Provision
Ground Bar Provision Main Disconnect
A A
B
B
C
C
N
Panel N
Panel
Catalog #
Catalog #
U217MTBL
U217MTBPL
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
Meter Mounting Equipment
44
Single Meter Sockets With Safety Socket Bypass
A
Test Block Bypass - Wiring Diagrams Ground Bar Provision
Ground Bar Provision Main Disconnect
Main Disconnect
B
A
B
A
N N Panel Panel
Catalog #
Catalog #
U224MTBL
U224MTBPL
Ground Bar Provision
Ground Bar Provision
Single Meter Sockets With Safety Socket Bypass
Main Disconnect
B
A
Main Disconnect
C A
B
C
N
N Panel Panel
Catalog #
Catalog #
U225MTBL
U225MTBPL
Ground Bar Provision Ground Bar Provision Main Disconnect
Main Disconnect
A
B
C
A
B
C
N
N Panel
Panel
Catalog #
Catalog #
U227MTBL
U227MTBPL
Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
45
Meter Mounting Equipment
Test Block Bypass - Safety Socket Bypass Instructions THIS PROCEDURE SHOULD BE PERFORMED ONLY BY QUALIFIED UTILITY PERSONNEL Step 1
Step 2
Test Block in normal operation. All screw terminals are in the closed position and tightened to the required torque specification.
Loosen Terminal Bypass Nuts.
Step 5
Picture shows the “Bypass Link” used to bypass the meter. (Normally supplied by utility)
Step 6
Single Meter Sockets With Safety Socket Bypass
Step 4
Step 3
Install Bypass Link as shown and tighten the Terminal Bypass Nuts to required torque specifications.
With Bypass Link securely in place, loosen Circuit Closing Nuts. All current and voltage potential has now been isolated from the socket. Meter may now be safely removed from socket.
Step 7
After meter has been replaced, securely tighten the Circuit Closing Nut to required torque specification. Step 8
Torque table for 100 & 200 Amp units. Circuit Closing Nuts: 60 in-lbs Terminal Bypass Nuts: 45 in-lbs
Loosen Terminal Bypass Nuts and remove Bypass Link. Meter is now energized.
Tighten Terminal Bypass Nuts.
Data subject to change without notice. Consult local utility for area acceptance.
Meter Mounting Equipment
46
Notes
Single Meter Sockets With Safety Socket Bypass Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches.
47
Meter Mounting Equipment