Preview only show first 10 pages with watermark. For full document please download

Single Meter Sockets - With Safety Socket Bypass

   EMBED


Share

Transcript

Single Meter Sockets With Safety Socket Bypass Single Meter Sockets - With Safety Socket Bypass Single Meter Sockets, With Safety Socket Bypass, 100 & 200 Amp . . . . . . . . . . . . . . . . . . . . 23 - 24 Single Meter Sockets, With Safety Socket Bypass, 100 Amp - 10K AIC . . . . . . . . . . . . . . . . 25 - 26 Meter Mains, With Safety Socket Bypass, 100 & 200 Amp - 22K-65K AIC . . . . . . . . . . . . . 27 - 28 Meter Mains, With Safety Socket Bypass, 100 Amp - Fusible Pullout . . . . . . . . . . . . . . . . . . 29 - 30 Meter Mains Load Center With Safety Socket Bypass, 100 Amp . . . . . . . . . . . . . . . . . . . . . . . . 31 - 32 Meter Mains Load Center With Safety Socket Bypass, 200 Amp - 10K AIC . . . . . . . . . . . . 33 - 34 Meter Mains Load Center With Safety Socket Bypass, 200 Amp - 22K-65K AIC . . . . . . 35 - 36 Meter Mains Load Center With Safety Socket Bypass, 200 Amp - Fused Pullout . . . . . 37 - 38 Meter Mains Load Center With Safety Socket Bypass, 200 Amp . . . . . . . . . . . . . . . . . . . . . . . . 39 - 40 Test Block Bypass - Metering Breaker Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 - 45 Test Block Bypass - Safety Socket Bypass Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Meter Mounting Equipment 22 Single Meter Sockets - With Safety Socket Bypass 100 & 200 Amp Application • Safety socket bypass (test block bypass) under separate cover • Receive ANSI C12.10 watthour meters • Surface mount Construction • Ring type • NEMA Type 3R • ANSI 61 gray E-coat finish • Aluminum snap ring included 117TB (closed) Standards • UL 414 Listed • ANSI C12.7 • EUSERC 304 & 305 117TB (open) Accessories • 5th Jaw Kit - 50371 • Bussed Gutters - see page 51 • AW Hubs Single Meter Sockets With Safety Socket Bypass Part/UPC Number 78205147005 78205147025 78205147030 78205159005 78205159025 78205159035 Part/UPC Number 78205147005 78205147025 78205147030 78205159005 78205159025 78205159035 Catalog Number 114 TB * 115 TB * 117 TB * 124 TB ** 125 TB ** 127 TB ** Catalog Number 114 TB * 115 TB * 117 TB * 124 TB ** 125 TB ** 127 TB ** Amp Rating Jaws Service Type Access Bypass Line Connections Load Neutral 100 100 100 200 200 200 4 5 7 4 5 7 1Ø/3W 3Ø/3W 3Ø/4W 1Ø/3W 3Ø/3W 3Ø/4W OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG TB TB TB TB TB TB #14 - 2/0 #14 - 2/0 #14 - 2/0 #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM 14 - 2/0 14 - 2/0 14 - 2/0 #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #14 - 1/0 #14 - 1/0 #14 - 1/0 1/0 - 250 MCM 1/0 - 250 MCM 1/0 - 250 MCM Height Overall Dimensions Width Depth Top Provision Knockout Layout 45/8” 45/8” 45/8” 6” 6” 6” AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub Fig. 1 Fig. 1 Fig. 1 Fig. 2 Fig. 2 Fig. 2 24” 24” 24” 30” 30” 30” 12” 12” 12” 14” 14” 14” * 100 Amp units compliant with EUSERC 304 ** 200 Amp units compliant with EUSERC 305 Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. 23 Meter Mounting Equipment Single Meter Sockets - With Safety Socket Bypass 100 & 200 Amp Knockouts - Conduit Sizes Style # 114 TB 115 TB 117 TB 124 TB 125 TB 127 TB Suffixes 2A = 1⁄2" - 1⁄4" 4F = 2" - 11⁄2" - 11⁄4" - 1” 4G = 21⁄2" - 2” - 11⁄2" - 11⁄4" 3H = 3” - 21⁄2" - 2" Top Provision = See Chart F - Flush Mount MS20 - Ring Protector MS28 - Barriers on both sides of test block SS - Stainless Steel Knockout Layouts Fig. 1 Fig. 2 Top Provision Single Meter Sockets With Safety Socket Bypass Top Provision 4F 4G 2A 4G 2A 4F 4F 3H both sides 4G 4F 3H both sides 3H Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Meter Mounting Equipment 24 Meter Mains - With Safety Socket Bypass 100 Amp - 10K AIC Application • Combination meter/main with safety socket (test block) bypass • Factory installed breaker • Receive ANSI C12.10 watthour meters • Surface mount Construction • Ring type • NEMA Type 3R • ANSI 61 gray E-coat finish • Aluminum snap ring included Standards • UL 67 Listed • ANSI C12.7 • EUSERC 305A U214 MTB (open) Accessories • 5th Jaw Kit - 50371 • Bussed Gutters - see page 51 • AW Hubs 214 MTB (closed) Single Meter Sockets With Safety Socket Bypass Part/UPC Number 78205145022 78205145032 78205145052 78205145060 78205145072 78205145078 78205145012 78205145112 78205145142 78205145150 78205145152 78205145158 Catalog Number 214 MTB 214 MTB MS15 215 MTB 215 MTB MS15 217 MTB 217 MTB MS15 U214 MTB U214 MTB MS15 U215 MTB U215 MTB MS15 U217 MTB U217 MTB MS15 Amp Rating Jaws Service Type Access Voltage Main Breaker AIC 100 100 100 100 100 100 100 100 100 100 100 100 4 4 5 5 7 7 4 4 5 5 7 7 1Ø/3W 1Ø/3W 3Ø/3W 3Ø/3W 3Ø/4W 3Ø/4W 1Ø/3W 1Ø/3W 3Ø/3W 3Ø/3W 3Ø/4W 3Ø/4W OH OH OH OH OH OH OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG 120/240 240/480 240* 480* 120/240 & 120/208 277/480 120/240 240/480 240* 480* 120/240 & 120/208 277/480 10K 10K 10K 10K 10K 10K 10K 10K 10K 10K 10K 10K Main Bypass (1) 100A, 2P (1) 100A, 2P (1) 100A, 3P (1) 100A, 3P (1) 100A, 3P (1) 100A, 3P (1) 100A, 2P (1) 100A, 2P (1) 100A, 3P (1) 100A, 3P (1) 100A, 3P (1) 100A, 2P TB TB TB TB TB TB TB TB TB TB TB TB * For a 208/120V, 1Ø/3W system, order a 4-jaw unit and a 5th jaw kit Part/UPC Number 78205145022 78205145032 78205145052 78205145060 78205145072 78205145078 78205145012 78205145112 78205145142 78205145150 78205145152 78205145158 Catalog Number 214 MTB 214 MTB MS15 215 MTB 215 MTB MS15 217 MTB 217 MTB MS15 U214 MTB U214 MTB MS15 U215 MTB U215 MTB MS15 U217 MTB U217 MTB MS15 Line Connections Load Neutral Height #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 38” 38” 38” 38” 38” 38” 24” 24” 24” 24” 24” 24” Overall Dimensions Width Depth Top Provision Knockout Layout 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 12” 12” 12” 12” 12” 12” 18” 18” 18” 18” 18” 18” MCB - Main Circuit Breaker Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. 25 Meter Mounting Equipment Meter Mains - With Safety Socket Bypass 100 Amp - 10K AIC Knockouts - Conduit Sizes Style # Suffixes (U) 214 MTB (U) 215 MTB (U) 217 MTB 1A = 1⁄2" 2A = 1⁄2" - 1⁄4" 4F = 2" - 11⁄2" - 11⁄4" - 1” 4G = 21⁄2" - 2” - 11⁄2" - 11⁄4" Top Provision = See Chart MS15 - 480V Breaker MS43 - No Breaker Included SS - Stainless Steel Knockout Layouts Fig. 1 Top Provision Top Provision 4F 4F 4G 4F 4F 2A both sides 4G 4F both sides 4F 4F 4F 1A 1A 4F Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Meter Mounting Equipment 26 Single Meter Sockets With Safety Socket Bypass Fig. 2 Meter Mains - With Safety Socket Bypass 100 & 200 Amp - 22K - 65K AIC Application • • • • Combination meter/main with safety socket (test block) bypass Factory installed breaker Receive ANSI C12.10 watthour meters Surface mount Construction • Ring type • NEMA Type 3R • ANSI 61 gray E-coat finish • Aluminum snap ring included 214 MTBH (open) Part/UPC Number Single Meter Sockets With Safety Socket Bypass 78205145030 78205159300 78205145028 78205145058 78205159302 78205145056 78205145076 78205159304 78205145074 78205145110 78205159200 78205145108 78205145148 78205159202 78205145146 78205145156 78205159204 78205145154 Part/UPC Number 78205145030 78205159300 78205145028 78205145058 78205159302 78205145056 78205145076 78205159304 78205145074 78205145110 78205159200 78205145108 78205145148 78205159202 78205145146 78205145156 78205159204 78205145154 Standards • UL 67 Listed • ANSI C12.7 • EUSERC 305A U214 MTBH (open) Catalog Number 214 MTBH 214 MTBH MS15 214 MTBH MS45 215 MTBH 215 MTBH MS15 215 MTBH MS45 217 MTBH 217 MTBH MS15 217 MTBH MS45 U214 MTBH U214 MTBH MS15 U214 MTBH MS45 U215 MTBH U215 MTBH MS15 U215 MTBH MS45 U217 MTBH U217 MTBH MS15 U217 MTBH MS45 Catalog Number 214 MTBH 214 MTBH MS15 214 MTBH MS45 215 MTBH 215 MTBH MS15 215 MTBH MS45 217 MTBH 217 MTBH MS15 217 MTBH MS45 U214 MTBH U214 MTBH MS15 U214 MTBH MS45 U215 MTBH U215 MTBH MS15 U215 MTBH MS45 U217 MTBH U217 MTBH MS15 U217 MTBH MS45 Amp Rating Jaws Service Type Access 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 4 4 4 5 5 5 7 7 7 4 4 4 5 5 5 7 7 7 1Ø/3W 1Ø/3W 1Ø/3W 3Ø/3W 3Ø/3W 3Ø/3W 3Ø/4W 3Ø/4W 3Ø/4W 1Ø/3W 1Ø/3W 1Ø/3W 3Ø/3W 3Ø/3W 3Ø/3W 3Ø/4W 3Ø/4W 3Ø/4W OH OH OH OH OH OH OH OH OH OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG Accessories • 5th Jaw Kit - 50371 • Bussed Gutters - see page 51 • AW Hubs Voltage Main Breaker AIC Main Bypass 120/240 65K (1) 100A, 2P TB 240/480 42K (1) 100A, 2P TB 120/240 22K (1) 100A, 2P TB 240* 65K (1) 100A, 3P TB 480* 42K (1) 100A, 3P TB 240* 22K (1) 100A, 3P TB 120/240 & 120/208 65K (1) 100A, 3P TB 480/277 42K (1) 100A, 3P TB 120/240 & 120/208 22K (1) 100A, 3P TB 120/240 65K (1) 100A, 2P TB 240/480 42K (1) 100A, 2P TB 120/240 22K (1) 100A, 2P TB 240* 65K (1) 100A, 3P TB 480* 42K (1) 100A, 3P TB 240* 22K (1) 100A, 3P TB 120/240 & 120/208 65K (1) 100A, 3P TB 480/277 42K (1) 100A, 3P TB 120/240 & 120/208 22K (1) 100A, 3P TB * For a 208/120V, 1Ø/3W system, order a 4-jaw unit and a 5th jaw kit Line Connections Load Neutral Height #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 38” 38” 38” 38” 38” 38” 38” 38” 38” 24” 24” 24” 24” 24” 24” 24” 24” 24” Overall Dimensions Width Depth Top Provision Knockout Layout 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 12” 12” 12” 12” 12” 12” 12” 12” 12” 18” 18” 18” 18” 18” 18” 18” 18” 18” MCB - Main Circuit Breaker Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. 27 Meter Mounting Equipment Meter Mains - With Safety Socket Bypass 100 & 200 Amp - 22K - 65K AIC Knockouts - Conduit Sizes Style # Suffixes (U) 214 MTBH (U) 215 MTBH (U) 217 MTBH 1A = 1⁄2" 2A = 1⁄2" - 1⁄4" 4F = 2" - 11⁄2" - 11⁄4" - 1” 4G = 21⁄2" - 2” - 11⁄2" - 11⁄4" Top Provision = See Chart MS15 - 480V Breaker MS43 - No Breaker Included MS45 - 22K AIC Rated Breaker SS - Stainless Steel Knockout Layouts Fig. 1 Top Provision Top Provision 4F 4F 4G 4F 4F 2A both sides 4G 4F both sides 4F 4F 4F 1A 1A 4F Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Meter Mounting Equipment 28 Single Meter Sockets With Safety Socket Bypass Fig. 2 Meter Mains - With Safety Socket Bypass 100 Amp - Fusible Pullout Application • Combination meter/main with safety socket (test block) bypass • Factory installed fused pullout (“T” fuses included) • Receive ANSI C12.10 watthour meters • Surface mount Construction • Ring type • NEMA Type 3R • ANSI 61 gray E-coat finish • Aluminum snap ring included Standards • UL 67 Listed • ANSI C12.7 • EUSERC 305A U214 MTBP (open) Accessories • 5th Jaw Kit - 50371 • Bussed Gutters - see page 51 • AW Hubs 214 MTBP (open) Single Meter Sockets With Safety Socket Bypass Part/UPC Number 78205148000 78205152000 78205148020 78205152010 78205148030 78205152020 78205148080 78205152060 78205148100 78205152070 78205148110 78205152100 Catalog Number 214 MTBP 214 MTBP MS15 215 MTBP 215 MTBP MS15 217 MTBP 217 MTBP MS15 U214 MTBP U214 MTBP MS15 U215 MTBP U215 MTBP MS15 U217 MTBP U217 MTBP MS15 Amp Rating Jaws Service Type Access Voltage Main Breaker AIC 100 100 100 100 100 100 100 100 100 100 100 100 4 4 5 5 7 7 4 4 5 5 7 7 1Ø/3W 1Ø/3W 3Ø/3W 3Ø/3W 3Ø/4W 3Ø/4W 1Ø/2W 1Ø/2W 3Ø/3W 3Ø/3W 3Ø/4W 3Ø/4W OH OH OH OH OH OH OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG 120/240 240/480 240* 480* 120/240 & 120/208 480/277 120/240 240/480 240* 480* 120/240 & 120/208 480/277 200K 200K 200K 200K 200K 200K 200K 200K 200K 200K 200K 200K Main Bypass (1) 100A, 2P (1) 100A, 2P (1) 100A, 3P (1) 100A, 3P (1) 100A, 3P (1) 100A, 3P (1) 100A, 2P (1) 100A, 2P (1) 100A, 3P (1) 100A, 3P (1) 100A, 3P (1) 100A, 3P TB TB TB TB TB TB TB TB TB TB TB TB * For a 208/120V, 1Ø/3W system, order a 4-jaw unit and a 5th jaw kit Part/UPC Number 78205148000 78205152000 78205148020 78205152010 78205148030 78205152020 78205148080 78205152060 78205148100 78205152070 78205148110 78205152100 Catalog Number 214 MTBP 214 MTBP MS15 215 MTBP 215 MTBP MS15 217 MTBP 217 MTBP MS15 U214 MTBP U214 MTBP MS15 U215 MTBP U215 MTBP MS15 U217 MTBP U217 MTBP MS15 Line Connections Load Neutral Height #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 Main Fuse Main Fuse Main Fuse Main Fuse Main Fuse Main Fuse Main Fuse Main Fuse Main Fuse Main Fuse Main Fuse Main Fuse #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 38” 38” 38” 38” 38” 38” 24” 24” 24” 24” 24” 24” Overall Dimensions Width Depth Top Provision Knockout Layout 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 12” 12” 12” 12” 12” 12” 18” 18” 18” 18” 18” 18” Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. 29 Meter Mounting Equipment Meter Mains - With Safety Socket Bypass 100 Amp - Fusible Pullout Knockouts - Conduit Sizes Style # Suffixes (U) 214 MTBP (U) 215 MTBP (U) 217 MTBP 1A = 1⁄2" 2A = 1⁄2" - 1⁄4" 4F = 2" - 11⁄2" - 11⁄4" - 1” 4G = 21⁄2" - 2” - 11⁄2" - 11⁄4" Top Provision = See Chart P - Pullout Fuse MS15 - 480V Breaker MS43 - No Breaker Included SS - Stainless Steel Knockout Layouts Fig. 1 Top Provision Top Provision 4F 4F 4G 4F 4F 2A both sides 4G 4F both sides 4F 4F 4F 1A 1A 4F Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Meter Mounting Equipment 30 Single Meter Sockets With Safety Socket Bypass Fig. 2 Meter Main Load Center - With Safety Socket Bypass 100 Amp Application • Combination meter/main/loadcenter with safety socket (test block) bypass • Factory installed breakers / fused pullout (“T” fuses included) • Receive ANSI C12.10 watthour meters • Surface mount Construction • Ring type • NEMA Type 3R • ANSI 61 gray E-coat finish • Aluminum snap ring included Standards • UL 67 Listed • ANSI C12.7 U214 MTBL (closed) Accessories • 5th Jaw Kit - 50371 • Bussed Gutters - see page 51 • AW Hubs Single Meter Sockets With Safety Socket Bypass U214 MTBL (open) Part/UPC Number Catalog Number Amp Rating Jaws Service Type Access 78205170126 78205170128 78205170130 78205170132 78205170134 78205170136 U214 MTBL U214 MTBPL U215 MTBL U215 MTBPL U217 MTBL U217 MTBPL 100 100 100 100 100 100 4 4 5 5 7 7 1Ø/3W 1Ø/3W 3Ø/4W 3Ø/4W 3Ø/4W 3Ø/4W OH/UG 120/240 OH/UG 120/240 OH/UG 240* OH/UG 240* OH/UG 120/240 & 120/208 OH/UG 120/208 Voltage Main Breaker AIC 10K 10K 10K 10K 10K 10K Main Loadcenter Bypass (1) 100A, 2P (1) 100A, 2P (1) 100A, 3P (1) 100A, 3P (1) 100A, 3P (1) 100A, 3P 12/24 12/24 18/36 18/36 18/36 18/36 TB TB TB TB TB TB * For a 208/120V, 1Ø/3W system, order a 4-jaw unit and a 5th jaw kit Part/UPC Number Catalog Number Line Connections Load Neutral Height 78205170126 78205170128 78205170130 78205170132 78205170134 78205170136 U214 MTBL U214 MTBPL U215 MTBL U215 MTBPL U217 MTBL U217 MTBPL #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 MCB Main Fuse MCB Main Fuse MCB Main Fuse #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 #14 - 1/0 24” 24” 24” 28” 24” 28” Overall Dimensions Width Depth Top Provision Knockout Layout 45/8” 45/8” 45/8” 45/8” 45/8” 45/8” AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub Fig. 1 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 20” 25” 25” 25” 25” 25” MCB - Main Circuit Breaker Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. 31 Meter Mounting Equipment Meter Main Load Center - With Safety Socket Bypass 100 Amp Knockouts - Conduit Sizes Style # Suffixes (U) 214 MTBL (U) 214 MTBPL (U) 215 MTBL (U) 215 MTBPL (U) 217 MTBL (U) 217 MTBPL 1A = 1⁄2" 2B = 3⁄4" - 1⁄2" 4D = 11⁄4" - 1” - 3⁄4" - 1⁄2" 4E = 11⁄2" - 11⁄4" - 1” - 3⁄4" 4F = 2" - 11⁄2" - 11⁄4" - 1” 4G = 21⁄2" - 2” - 11⁄2" - 11⁄4" Top Provision = See Chart P - Pullout Fuse MS43 - No Breaker Included SS - Stainless Steel Knockout Layouts Fig. 1 Fig. 2 Top Provision Single Meter Sockets With Safety Socket Bypass Top Provision 1A (6) 4E 4E 1A (4) 1A 4G 4E 1A 2B 4G (2) 1A 2B 4D 1A (5) 1A (4) 2B 4F (3) 4F 4E 4E 2B Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Meter Mounting Equipment 32 Meter Main Load Center - With Safety Socket Bypass 200 Amp - 10K AIC Application • Combination meter/main with safety socket (test block) bypass • Factory installed breaker • Receive ANSI C12.10 watthour meters • Surface mount Construction • Ring type • NEMA Type 3R • ANSI 61 gray E-coat finish • Aluminum snap ring included Standards • UL 67 Listed • ANSI C12.7 • EUSERC 305A Accessories • 5th Jaw Kit - 50371 • Bussed Gutters - see page 51 • AW Hubs U224 MTB (open) 224 MTB (open) Single Meter Sockets With Safety Socket Bypass Part/UPC Number Catalog Number Amp Rating Jaws Service Type Access Voltage Main Breaker AIC 78205159065 78205159085 78205159095 78205170141 78205159125 78205159145 78205159155 224 MTB 225 MTB 227 MTB U224 M11TB U224 MTB U225 MTB U227 MTB 200 200 200 200 200 200 200 4 5 7 4 4 5 7 1Ø/3W 3Ø/3W 3Ø/4W 1Ø/3W 1Ø/3W 3Ø/3W 3Ø/4W OH OH OH OH/UG OH/UG OH/UG OH/UG 120/240 240* 120/240 & 120/208 120/240 120/240 240* 120/240 & 120/208 10K 10K 10K 10K 10K 10K 10K Main Bypass (1) 200A, 2P (1) 200A, 3P (1) 200A, 3P (2) 100A, 2P (1) 200A, 2P (1) 200A, 3P (1) 200A, 3P TB TB TB TB TB TB TB * For a 208/120V, 1Ø/3W system, order a 4-jaw unit and a 5th jaw kit Part/UPC Number Catalog Number Line Connections Load Neutral Height 78205159065 78205159085 78205159095 78205170141 78205159125 78205159145 78205159155 224 MTB 225 MTB 227 MTB U224 M11TB U224 MTB U225 MTB U227 MTB #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM MCB MCB MCB MCB MCB MCB MCB #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM 48” 48” 48” 30” 30” 30” 30” Overall Dimensions Width Depth 14” 14” 14” 22” 22” 22” 22” 6” 6” 6” 6” 6” 6” 6” Top Provision Knockout Layout AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub Fig. 1 Fig. 1 Fig. 1 Fig. 3 Fig. 2 Fig. 2 Fig. 2 MCB - Main Circuit Breaker Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. 33 Meter Mounting Equipment Meter Main Load Center - With Safety Socket Bypass 200 Amp - 10K AIC Knockouts - Conduit Sizes Style # Suffixes (U) 224 MTB (U) 224 M11TB (U) 225 MTB (U) 227 MTB 1A = 1⁄2" 2A = 1⁄2" - 1⁄4" 4E = 11⁄2" - 11⁄4" - 1” - 3⁄4" 4G = 21⁄2" - 2” - 11⁄2" - 11⁄4" 2H = 3" - 21⁄2" 3H = 3” - 21⁄2" - 2" 4H = 3” - 21⁄2" - 2” - 11⁄2" Top Provision = See Chart MS43 - No Breaker Included SS - Stainless Steel Knockout Layouts Fig. 1 Fig. 2 Top Provision Single Meter Sockets With Safety Socket Bypass Top Provision 4G 4G 2H 4G 3H both sides 4G both sides 3H 2A 3H 1A 2H 2H 1A 4G Fig. 3 Top Provision 4G 4E 4G 4G both sides 1A 1A 4H Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Meter Mounting Equipment 34 Meter Main - With Safety Socket Bypass 200 Amp - 22K-65K AIC Application • • • • Combination meter/main with safety socket (test block) bypass Factory installed breaker Receive ANSI C12.10 watthour meters Surface mount Construction • Ring type • NEMA Type 3R • ANSI 61 gray E-coat finish • Aluminum snap ring included Standards • UL 67 Listed • ANSI C12.7 • EUSERC 305A U224 MTBH (open) 224 MTBH (open) Part/UPC Number Single Meter Sockets With Safety Socket Bypass 78205159081 78205159306 78205159079 78205159091 78205159308 78205159089 78205159159 78205159310 78205159097 78205159141 78205159206 78205159139 78205159151 78205159208 78205159149 78205159159 78205159210 78205159157 Part/UPC Number 78205159081 78205159306 78205159079 78205159091 78205159308 78205159089 78205159159 78205159310 78205159097 78205159141 78205159206 78205159139 78205159151 78205159208 78205159149 78205159159 78205159210 78205159157 Catalog Number 224 MTBH 224 MTBH MS15 224 MTBH MS45 225 MTBH 225 MTBH MS15 225 MTBH MS45 227 MTBH 227 MTBH MS15 227 MTBH MS45 U224 MTBH U224 MTBH MS15 U224 MTBH MS45 U225 MTBH U225 MTBH MS15 U225 MTBH MS45 U227 MTBH U227 MTBH MS15 U227 MTBH MS45 Catalog Number 224 MTBH 224 MTBH MS15 224 MTBH MS45 225 MTBH 225 MTBH MS15 225 MTBH MS45 227 MTBH 227 MTBH MS15 227 MTBH MS45 U224 MTBH U224 MTBH MS15 U224 MTBH MS45 U225 MTBH U225 MTBH MS15 U225 MTBH MS45 U227 MTBH U227 MTBH MS15 U227 MTBH MS45 Amp Rating Jaws Service Type 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 4 4 4 5 5 5 7 7 7 4 4 4 5 5 5 7 7 7 1Ø/3W 1Ø/3W 1Ø/3W 3Ø/3W 3Ø/3W 3Ø/3W 3Ø/4W 3Ø/4W 3Ø/4W 1Ø/3W 1Ø/3W 1Ø/3W 3Ø/3W 3Ø/3W 3Ø/3W 3Ø/4W 3Ø/4W 3Ø/4W Access Accessories • 5th Jaw Kit - 50371 • Bussed Gutters - see page 51 • AW Hubs Voltage Main Breaker AIC Main Bypass OH 120/240 42K (1) 200A, 2P TB OH 240/480 22K (1) 200A, 2P TB OH 120/240 22K (1) 200A, 2P TB OH 240* 42K (1) 200A, 3P TB OH 480* 22K (1) 200A, 3P TB OH 240* 22K (1) 200A, 3P TB OH 120/240 & 120/208 42K (1) 200A, 3P TB OH 480/277 22K (1) 200A, 3P TB OH 120/240 & 120/208 22K (1) 200A, 3P TB OH/UG 120/240 42K (1) 200A, 2P TB OH/UG 240/480 22K (1) 200A, 2P TB OH/UG 120/240 22K (1) 200A, 2P TB OH/UG 240* 42K (1) 200A, 3P TB OH/UG 480* 22K (1) 200A, 3P TB OH/UG 240* 22K (1) 200A, 3P TB OH/UG 120/240 & 120/208 42K (1) 200A, 3P TB OH/UG 480/277 22K (1) 200A, 3P TB OH/UG 120/240 & 120/208 22K (1) 200A, 3P TB * For a 208/120V, 1Ø/3W system, order a 4-jaw unit and a 5th jaw kit Line Connections Load Neutral Height #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM 48” 48” 48” 48” 48” 48” 48” 48” 48” 30” 30” 30” 30” 30” 30” 30” 30” 30” Overall Dimensions Width Depth 14” 14” 14” 14” 14” 14” 14” 14” 14” 22” 22” 22” 22” 22” 22” 22” 22” 22” 6” 6” 6” 6” 6” 6” 6” 6” 6” 6” 6” 6” 6” 6” 6” 6” 6” 6” Top Provision Knockout Layout AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 MCB - Main Circuit Breaker Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. 35 Meter Mounting Equipment Meter Main - With Safety Socket Bypass 200 Amp - 22K-65K AIC Knockouts - Conduit Sizes Style # Suffixes (U) 224 MTBH (U) 225 MTBH (U) 227 MTBH 1A = 1⁄2" 2A = 1⁄2" - 1⁄4" 4G = 21⁄2" - 2” - 11⁄2" - 11⁄4" 2H = 3" - 21⁄2" 3H = 3” - 21⁄2" - 2" Top Provision = See Chart MS15 - 480V Breaker MS43 - No Breaker Included MS45 - 22K AIC Rated Breaker SS - Stainless Steel Knockout Layouts Fig. 1 Fig. 2 Top Provision Single Meter Sockets With Safety Socket Bypass Top Provision 4G 4G 2H 4G 3H both sides 4G both sides 3H 2A 3H 2H 1A 2H 1A 4G Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Meter Mounting Equipment 36 Meter Main - With Safety Socket Bypass 200 Amp - Fusible Pullout Application • • • • Combination meter/main with safety socket (test block) bypass Factory installed breaker Receive ANSI C12.10 watthour meters Surface mount Construction • Ring type • NEMA Type 3R • ANSI 61 gray E-coat finish • Aluminum snap ring included Standards • UL 67 Listed • ANSI C12.7 • EUSERC 305A 224 MTBP (open) Single Meter Sockets With Safety Socket Bypass Part/UPC Number 78205161000 78205163000 78205161080 78205107971 78205161100 78205163020 78205162000 78205163040 78205162080 78205163050 78205162100 78205163060 Accessories • 5th Jaw Kit - 50371 • Bussed Gutters - see page 51 • AW Hubs U224 MTBP (open) Catalog Number 224 MTBP 224 MTBP MS15 225 MTBP 225 MTBP MS15 227 MTBP 227 MTBP MS15 U224 MTBP U224 MTBP MS15 U225 MTBP U225 MTBP MS15 U227 MTBP U227 MTBP MS15 Amp Rating Jaws Service Type Access Voltage Main Breaker AIC 200 200 200 200 200 200 200 200 200 200 200 200 4 4 5 5 7 7 4 4 5 5 7 7 1Ø/3W 1Ø/3W 3Ø/3W 3Ø/3W 3Ø/4W 3Ø/4W 1Ø/3W 1Ø/3W 3Ø/3W 3Ø/3W 3Ø/4W 3Ø/4W OH OH OH OH OH OH OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG 120/240 240/480 240* 480* 120/240 & 120/208 480/277 120/240 240/480 240* 480* 120/240 & 120/208 480/277 200K 200K 200K 200K 200K 200K 200K 200K 200K 200K 200K 200K Main Bypass (1) 200A, 2P (1) 200A, 2P (1) 200A, 3P (1) 200A, 3P (1) 200A, 3P (1) 200A, 3P (1) 200A, 2P (1) 200A, 2P (1) 200A, 3P (1) 200A, 3P (1) 200A, 3P (1) 200A, 3P TB TB TB TB TB TB TB TB TB TB TB TB * For a 208/120V, 1Ø/3W system, order a 4-jaw unit and a 5th jaw kit Part/UPC Number 78205161000 78205163000 78205161080 78205107971 78205161100 78205163020 78205162000 78205163040 78205162080 78205163050 78205162100 78205163060 Catalog Number 224 MTBP 224 MTBP MS15 225 MTBP 225 MTBP MS15 227 MTBP 227 MTBP MS15 U224 MTBP U224 MTBP MS15 U225 MTBP U225 MTBP MS15 U227 MTBP U227 MTBP MS15 Line Connections Load Neutral Height #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM MCB MCB MCB MCB MCB MCB Main Fuse Main Fuse Main Fuse Main Fuse Main Fuse Main Fuse #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM 48” 48” 48” 48” 48” 48” 30” 30” 30” 30” 30” 30” Overall Dimensions Width Depth 14” 14” 14” 14” 14” 14” 22” 22” 22” 22” 22” 22” 6” 6” 6” 6” 6” 6” 6” 6” 6” 6” 6” 6” Top Provision Knockout Layout AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Fig. 2 MCB - Main Circuit Breaker Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. 37 Meter Mounting Equipment Meter Main - With Safety Socket Bypass 200 Amp - Fusible Pullout Knockouts - Conduit Sizes Style # Suffixes (U) 224 MTBP (U) 225 MTBP (U) 227 MTBP 1A = 1⁄2" 2A = 1⁄2" - 1⁄4" 4G = 21⁄2" - 2” - 11⁄2" - 11⁄4" 2H = 3" - 21⁄2" 3H = 3” - 21⁄2" - 2" Top Provision = See Chart P - Pullout Fuse MS15 - 480V Breaker MS43 - No Breaker Included SS - Stainless Steel Knockout Layouts Fig. 1 Fig. 2 Top Provision Single Meter Sockets With Safety Socket Bypass Top Provision 4G 4G 2H 4G 3H both sides 4G both sides 3H 2A 3H 2H 1A 2H 1A 4G Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Meter Mounting Equipment 38 Meter Main Loadcenter - With Safety Socket Bypass 200 Amp Application • Combination meter/main/loadcenter with safety socket (test block) bypass • Factory installed breakers / fusible pullout (“T” fuses included) • Receive ANSI C12.10 watthour meters • Surface mount Construction • Ring type • NEMA Type 3R • ANSI 61 gray E-coat finish • Aluminum snap ring included U224 MTBL (closed) Standards • UL 67 Listed • ANSI C12.7 • EUSERC 305A U224 MTBL (open) Single Meter Sockets With Safety Socket Bypass Part/UPC Number Catalog Number Amp Rating Jaws Service Type Access Voltage Main Breaker AIC 78205170138 78205170140 78205170142 78205170144 78205170146 78205170148 U224 MTBL U224 MTBPL U225 MTBL U225 MTBPL U227 MTBL U227 MTBPL 200 200 200 200 200 200 4 4 5 5 7 7 1Ø/3W 1Ø/3W 3Ø/3W 3Ø/3W 3Ø/4W 3Ø/4W OH/UG OH/UG OH/UG OH/UG OH/UG OH/UG 120/240 120/240 240* 240* 120/240 & 120/208 120/240 & 120/208 10K 100K 10K 100K 10K 100K Main Loadcenter Bypass (1) 200A, 2P (1) 200A, 2P (1) 200A, 3P (1) 200A, 3P (1) 200A, 3P (1) 200A, 3P 20/40 20/40 24/42 24/42 24/42 24/42 TB TB TB TB TB TB * For a 208/120V, 1Ø/3W system, order a 4-jaw unit and a 5th jaw kit Part/UPC Number Catalog Number Line Connections Load Neutral Height 78205170138 78205170140 78205170142 78205170144 78205170146 78205170148 U224 MTBL U224 MTBPL U225 MTBL U225 MTBPL U227 MTBL U227 MTBPL #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM MCB Main Fuse MCB Main Fuse MCB Main Fuse #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM #6 - 250 MCM 30” 30” 32” 32” 32” 32” Overall Dimensions Width Depth 27” 27” 27” 27” 27” 27” 6” 6” 6” 6” 6” 6” Top Provision Knockout Layout AW Hub AW Hub AW Hub AW Hub AW Hub AW Hub Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 Fig. 1 MCB - Main Circuit Breaker Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. 39 Meter Mounting Equipment Meter Main Loadcenter - With Safety Socket Bypass 200 Amp Knockouts - Conduit Sizes Style # Suffixes (U) 224 MTBL (U) 224 MTBPL (U) 225 MTBL (U) 225 MTBPL (U) 227 MTBL (U) 227 MTBPL 1A = 1⁄2" 2B = 3⁄4" - 1⁄2" 4D = 11⁄4" - 1” - 3⁄4" - 1⁄2" 4E = 11⁄2" - 11⁄4" - 1” - 3⁄4" 2H = 3" - 21⁄2" Top Provision = See Chart P - Pullout Fuse MS43 - No Breaker Included SS - Stainless Steel Knockout Layouts Fig. 1 Single Meter Sockets With Safety Socket Bypass Top Provision 1A 2B (6) 4E (4) 2H 1A (9) 1A 4E 2B 4D 2B 4E Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Meter Mounting Equipment 40 Test Block Bypass - Metering Breaker Data Main Breaker Data Catalog Number Single Meter Sockets With Safety Socket Bypass B-Line Breaker # ITE Breaker # Ampacity Voltage # of Poles AIC 25458P 25460P 25460P 25464P 25466P 25466P 25470P 25472P 25472P 25534N 25536N 25536N 25544N 25546N 25546N 25458P 25460P 25460P 25508K 25510K 25510K 25512K 25514K 25514K 25516K 25518K 25518K 25552J 25554J 25554J Q2100 Q3100 Q3100 Q2100H Q3100H Q3100H Q2100HH Q3100HH Q3100HH ED42B100 ED43B100 ED43B100 HED42B100 HED43B100 HED43B100 Q2100 Q3100 Q3100 QJ22B200 QJ23B200 QJ23B200 QJH22B200H QJH23B200H QJH23B200H QJ22B200H QJ23B200H QJ23B200H FXD62B200 FXD63B200 FXD63B200 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 200A 200A 200A 200A 200A 200A 200A 200A 200A 200A 200A 200A 240 240 240 240 240 240 240 240 240 480 480 480 480 480 480 240 240 240 240 240 240 240 240 240 240 240 240 480 480 480 2P 3P 3P 2P 3P 3P 2P 3P 3P 2P 3P 3P 2P 3P 3P 2P 3P 3P 2P 3P 3P 2P 3P 3P 2P 3P 3P 2P 3P 3P 10K 10K 10K 22K 22K 22K 42K 42K 42K 10K 10K 10K 42K 42K 42K 10K 10K 10K 10K 10K 10K 22K 22K 22K 42K 42K 42K 22K 22K 22K B-Line Breaker # Boltswitch Pullout # Ampacity Voltage # of Poles AIC 20404A 20404B 20404B 20404E 20404F 20404F 20404C 20404D 20404D 20404G 20404H 20404H PT323-2P PT323 PT323 PT363-2P PT363 PT363 PT324-2P PT324 PT324 PT364-2P PT364 PT364 100A 100A 100A 100A 100A 100A 200A 200A 200A 200A 200A 200A 240 240 240 480 480 480 240 240 240 480 480 480 2P 3P 3P 2P 3P 3P 2P 3P 3P 2P 3P 3P 200K 200K 200K 200K 200K 200K 200K 200K 200K 200K 200K 200K B-Line Breaker # 25050A 25051A 25051A 25052A 25053A 25053A ITE Pullout # TFP223 TFP323 TFP323 TFP224 TFP324 TFP324 Ampacity Voltage AIC 100A 100A 100A 200A 200A 200A 240 240 240 240 240 240 # of Poles 2P 3P 3P 2P 3P 3P U214MTB U215MTB U217MTB U214MTBHMS45 U215MTBHMS45 U217MTBHMS45 U214MTBH U215MTBH U217MTBH U214MTBMS15 U215MTBMS15 U217MTBMS15 U214MTBHMS15 U215MTBHMS15 U217MTBHMS15 U214MTBL U215MTBL U217MTBL U224MTB U225MTB U227MTB U224MTBHMS45 U225MTBHMS45 U227MTBHMS45 U224MTBH U225MTBH U227MTBH U224MTBHMS15 U225MTBHMS15 U227MTBHMS15 Main Pullout Data Catalog Number U214MTBP U215MTBP U217MTBP U214MTBPMS15 U215MTBPMS15 U217MTBPMS15 U224MTBP U225MTBP U227MTBP U224MTBPMS15 U225MTBPMS15 U227MTBPMS15 Main Pullout Data Catalog Number U214MTBPL U215MTBPL U217MTBPL U224MTBPL U225MTBPL U227MTBPL 100K 100K 100K 100K 100K 100K Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. 41 Meter Mounting Equipment Test Block Bypass - Wiring Diagrams N L I N E O A L O A D L I N E B L O A D N L I N E O A L O A D L I N E L O A D L I N E B L O A D L I N E L O A D B A O N L I N E A L O A D Catalog # Catalog # 214MTB 214MTBHMS45 214MTBH 214MTBMS15 214MTBHMS15 224MTB 224MTBHMS45 224MTBH 224MTBMS15 214MTBP 214MTBPMS15 224MTBP 224MTBPMS15 U214MTB U214MTBMS15 U214MTBHMS15 U214MTBH U214MTBHMS45 U224MTB U224MTBH U224MTBHMS45 L I N E L O A D B Single Meter Sockets With Safety Socket Bypass Catalog # N L I N E O A L O A D L I N E L O A D B L I N E C L O A D N L I N E O A L O A D L I N E L O A D B L I N E C O N Catalog # Catalog # Catalog # U214MTBP U214MTBPMS15 U224MTBP U224MTBPMS15 215MTB 215MTBMS15 215MTBHMS15 215MTBH 215MTBHMS45 225MTB 225MTBH 225MTBHMS45 215MTBP 215MTBPMS15 225MTBP 225MTBPMS15 Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Meter Mounting Equipment 42 L O A D Test Block Bypass - Wiring Diagrams L I N E A L O A D L I N E B L O A D L I N E L I N E L O A D C L O A D A L I N E L I N E L O A D B L O A D C O O N N N L I N E O A L I N E L O A D L I N E L O A D B C Single Meter Sockets With Safety Socket Bypass Catalog # Catalog # Catalog # U215MTB U215MTBMS15 U215MTBHMS15 U215MTBH U215MTBHMS45 U225MTB U225MTBH U225MTBHMS45 U225MTBHMS15 U215MTBP U214MTBPMS15 U225MTBP U225MTBPMS15 U217MTB U217MTBMS15 U217MTBHMS15 U217MTBH U217MTBHMS45 U227MTB U227MTBH U227MTBHMS45 U227MTBHMS15 N L I N E O A L O A D L I N E L O A D L I N E B C L O A D L I N E A L O A D L I N E B L O A D L I N E L O A D L I N E C A L O A D L I N E B L O A D L I N E L O A D L O A D C O O N N Catalog # Catalog # Catalog # 217MTBP 217MTBPMS15 227MTBP 227MTBPMS15 U217MTB U217MTBMS15 U217MTBHMS15 U217MTBH U217MTBHMS45 U227MTB U227MTBMS15 U227MTBH U227MTBHMS45 U217MTBP U217MTBPMS15 U227MTBP U227MTBPMS15 Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. 43 Meter Mounting Equipment Test Block Bypass - Wiring Diagrams Ground Bar Provision Ground Bar Provision Main Disconnect Main Disconnect B B A N Panel N Panel Catalog # Catalog # U214MTBL U214MTBPL Ground Bar Provision Ground Bar Provision Main Disconnect Main Disconnect A A B B C C N N Panel Panel Catalog # Catalog # U215MTBL U215MTBPL Main Disconnect Ground Bar Provision Ground Bar Provision Main Disconnect A A B B C C N Panel N Panel Catalog # Catalog # U217MTBL U217MTBPL Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Meter Mounting Equipment 44 Single Meter Sockets With Safety Socket Bypass A Test Block Bypass - Wiring Diagrams Ground Bar Provision Ground Bar Provision Main Disconnect Main Disconnect B A B A N N Panel Panel Catalog # Catalog # U224MTBL U224MTBPL Ground Bar Provision Ground Bar Provision Single Meter Sockets With Safety Socket Bypass Main Disconnect B A Main Disconnect C A B C N N Panel Panel Catalog # Catalog # U225MTBL U225MTBPL Ground Bar Provision Ground Bar Provision Main Disconnect Main Disconnect A B C A B C N N Panel Panel Catalog # Catalog # U227MTBL U227MTBPL Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. 45 Meter Mounting Equipment Test Block Bypass - Safety Socket Bypass Instructions THIS PROCEDURE SHOULD BE PERFORMED ONLY BY QUALIFIED UTILITY PERSONNEL Step 1 Step 2 Test Block in normal operation. All screw terminals are in the closed position and tightened to the required torque specification. Loosen Terminal Bypass Nuts. Step 5 Picture shows the “Bypass Link” used to bypass the meter. (Normally supplied by utility) Step 6 Single Meter Sockets With Safety Socket Bypass Step 4 Step 3 Install Bypass Link as shown and tighten the Terminal Bypass Nuts to required torque specifications. With Bypass Link securely in place, loosen Circuit Closing Nuts. All current and voltage potential has now been isolated from the socket. Meter may now be safely removed from socket. Step 7 After meter has been replaced, securely tighten the Circuit Closing Nut to required torque specification. Step 8 Torque table for 100 & 200 Amp units. Circuit Closing Nuts: 60 in-lbs Terminal Bypass Nuts: 45 in-lbs Loosen Terminal Bypass Nuts and remove Bypass Link. Meter is now energized. Tighten Terminal Bypass Nuts. Data subject to change without notice. Consult local utility for area acceptance. Meter Mounting Equipment 46 Notes Single Meter Sockets With Safety Socket Bypass Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. 47 Meter Mounting Equipment