SIP SERIES REED RELAYS MVS4 ■ MSS4 DESCRIPTION REMtech offers a large selection of molded SIP relays to meet customer applications. The high performance MVS4 and MSS4 models provide bounce free operation and offer a more durable contact when switching capacitive or inductive loads. Both are capable of switching loads up to 50 watts. APPLICATIONS FEATURES ■ High reliability switching ■ Long operating life at low levels ( >1 ■ ■ ■ ■ ■ ■ ■ ■ ■ ATE - Functional board testers - Integrated circuit testers - Bare board testers ■ Telecom ■ Matrix requirements ■ Instrumentation ■ Data acquisition billion operations) Capable of switching up to 1000V High isolation between input and output (2500V) Optional internal diode & N.C. option High density board mounting Automatic insertion design State-of-the-art capsule designs Epoxy molded single-in-line package FCC68 compatible on MSS4 model RATINGS (@ 25ο C) Parameter Max Unit Switching voltage MSS4 MVS4 Min Typ 500 1000 Volts Volts Switching current MVS4/MSS4 2 Amps Carry current MSS4/ MVS4 3 Amps Switching frequency MVS4/MSS4 200 Hz Contact resistance MVS4/MSS4 100 mΩ (See detailed specifications for more information.) www.REMtechcorp.com TM A SUMIDA COMPANY 1 SIP SERIES REED RELAYS MVS4 ■ MSS4 SPECIFICATIONS MVS4 Non-Position-Sensitive Hg-Wetted SYMBOL MIN TYP MAX MIN TYP MAX VL IL IC CR - - 1000(1) 2 3 50(4) 100 - - - 1000 2 50 7(2) Hg 40 - 200 7 Hg 16 500 2 3 50 100 - IR 1010 1012 - 108 1010 - Ω I/O I/O TOP 2000 2500 - 0.8 2.2 3.3 - 2.5 2000 1400 - - 2 4 1.75 pF pF pF VDC/Peak AC VDC/Peak AC ms TREL - - 2.5 - - 1.5 ms TA TO G -40 -38 - - +105 +85 +260 10 -40 -38 - - +105 +75 +260 10 °C °C °C Gs S - - 30 - - 30 Gs - - 2.2 - - 2.4 - grams All parameters at 25°C unless otherwise stated. PARAMETER CONDITIONS MSS4 High Power/Reliability Position-Sensitive(3) Hg-Wetted Mercury-Wetted Reed Relays UNITS Contact Ratings Switching Voltage Switching Current Carry Current Contact Rating Life Expectancy Static Contact Resistance Contact Material Hg Content Max DC/PeakAC Resistive Max DC/PeakAC Resistive Max DC/PeakAC Resistive Max DC/PeakAC Resistive Signal Level 1.0V 10mA 50V, 1A 500V, 100mA Rated Loads 50mV, 10mA - - Volts Amps Amps Watts x106 Ops x106 Ops x106 Ops x106 Ops mΩ mgram Relay Specifications Insulation Resistance Capacitance Dielectric Strength Operate Time, no bounce Release Time Between all isolated pins at 100V, 25°C, 40% RH Across Open Contacts Upper Contact to Coil Closed Contact to Coil Between Contacts Contacts to Coil At Nominal Coil Voltage 10Hz Square Wave Zener-Diode Suppression Environmental Ratings Storage Temperature Operating Temperature Soldering Temperature Vibration Resistance (Survival) Shock Resistance (Survival) Weight (1) (2) (3) (4) Applied to pins,10 sec. max. 10Hz - 500Hz 1 11±1ms, /2 Sine Wave Current limited up to 5mA, typical 20 million operations; for further life information, consult factory. Refer to MVS4 life graph. Vertical mounting required. Pin #1 is up. Derate to 5 watts when switching voltages >500V. USA 1-877-4REMTECH Europe 32-11-300868 Japan 81-3-3667-3302 Ext. 2419 HongKong/China/Korea 852-2880-6773 Taiwan 886-2-2726-2177 Singapore/Far East 65-296-3388 2 TM A SUMIDA COMPANY SIP SERIES REED RELAYS MVS4 ■ MSS4 COIL SPECIFICATIONS Contact Form Coil Voltage Units Coil Resistance +/- 10% (25°C) Min Release Voltage Nominal Input Power Volts Volts mW Ω Volts Conditions Part # Operate Voltage Typ Max Min Typ Must operate by (25°C) Must release by (25°C) Max Min Typ Max Min Typ Max Min Typ MVS41A05(B) MVS41A12(B) MVS41A24(B) 1-Form-A 1-Form-A 1-Form-A 5 12 24 7 15 30 94.5 450 1935 105 116 500 550 2150 2365 3.75 9 18 0.5 1 2.0 238 288 268 MSS41A05 MSS41A12 MSS41A24 1-Form-A 1-Form-A 1-Form-A 5 12 24 10 16 30 126 450 1935 140 154 500 550 2150 2365 3.75 9 18 0.5 1 2 179 288 268 DIMENSIONS mm (inches) MECHANICAL DIMENSIONS MVS4/MSS4 Max 0.49 (0.019) 7 5 5.08 (0.200) 19.05 MAX. (0.750) 15.24 (0.600) 3 3.20 – 0.25 (0.125 – 0.010) 6.70 MAX. (0.264) 1 Top View 8.20 MAX. (0.323) MVS4/MSS4 Pinout 7 5 0.33 (0.013) * 3 UP 1 Top View * MVS4 only must be mounted vertically with pin #1 up. www.REMtechcorp.com TM A SUMIDA COMPANY 3 SIP SERIES REED RELAYS MVS4 ■ MSS4 PERFORMANCE GRAPHS Pull In/Drop Out vs. Temperature Relay Internal Temperature Rise vs. Power MVS4 Relay Temperature Rise vs. Coil Power (1-Form-A 5V) 2 50.0 30.0 20.0 10.0 5.0 3.0 2.0 1.0 1 0 -1 -2 50V-1A Load 3.897 x 10 ops 90% Survival 6 15.520 x 10 Ops MTBF 6 0.5 0.3 0.2 0.1 -3 -4 -5 20 80 60 40 20 0.1 1.0 10.0 10 0 -10 -20 -6 -7 100.0 MVS4/MSS4 Pull In/Drop Out vs. Temperature 30 100 % Change 99.9 Delta T ( C) of Relay % Cumm. Failures MVS Series Rated Load: 50VA-20Hz 0 0 -30 75 150 225 300 375 450 525 600 675 750 6 -40 Coil Input Power (mW) Number of Operations (x10 ) -20 0 20 40 80 60 100 Ambient Temperature (ßC) MAGNETIC INTERFERENCE If relays are inserted in close proximity, the pickup and dropout voltages will be affected by the magnetic flux produced when the coils are energized. The direction of the parameter shift is determined by whether the stray flux aids or bucks the flux produced by the coil of the relay under consideration. % P.I. and D.O. Increase In general, worst-case magnetic interaction conditions for pull-in voltage in a matrix exist when all relay fields have the same polarity and all of the fields are from adjacent relays (See figure). MVS4/MSS4 Magnetic Interference 10.0% Relay under test Adjacent Relays 7.5% 5.0% 2.5% 0.0% x x 1. Nominal voltage is applied to the adjacent relays. 2. The % increase of pull-in and drop out of the relay under test is measured and compared with the values without any magnetic influence of adjacent relays. 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.55 0.6 0.65 0.7 Distance Between Centers of Adjacent Relays (in inches) To calculate the change in pull-in voltage and dropout voltage, multiply the percent change shown by the relay’s nominal voltage. For example, if the percent change in pull-in voltage is 14% for a 5V nominal relay, the pull-in voltage will increase by 0.7 volts. ORDERING INFORMATION A complete part number is represented by the digits below. XXXX XX XX X Series Blank = No diode MVS4 MSS4 Contact Form 1A = 1-Form-A (Normally open) Coil voltage 05 = 5V 12 = 12V 24 = 24V USA 1-877-4REMTECH Europe 32-11-300868 Japan 81-3-3667-3302 Ext. 2419 HongKong/China/Korea 852-2880-6773 Taiwan 886-2-2726-2177 Singapore/Far East 65-296-3388 4 TM A SUMIDA COMPANY