GE Consumer & Industrial Power Protection Schematics Digital Energy™ SitePro 10 – 15 – 20 – 30 – 40 kVA 400 VAC CE / Serie 7 / 7M Manufactured by: GE Digital Energy General Electric Company CH – 6595 Riazzino (Locarno) Svizzera T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 51 44 www.gedigitalenergy.com Model: SitePro 10 – 15 - 20 kVA, Serie 7M + SitePro 30 - 40 kVA, Serie 7 Date of issue: 01.08.2005 File name: EDW_SPE_XXX_10K_40K_7GB_V020 Revision: 2.0 Identification No.: Up-dating Revision Concern Date 2.0 ECN842 (EMC standard class A for SitePro 10 – 15 - 20, Serie 7M) 01.08.2005 TECHNICAL DIAGRAMS Table of contents for SitePro 10 – 15 - 20 kVA, Serie 7M Drawing title: Drawing number: Functional Diagram UPS Assembly Layout AC Input AC Input + Rectifier Inverter / Bypass Bridges and Output Load Details for Bridges: Rectifier – Inverter - SSM AC Input with Option 5th + 11th Harmonic Filter 360 213 360 213 360 213 360 213 360 213 360 213 360 213 page page page page page page page 1/7 2/7 3/7 4/7 5/7 6/7 7/7 Table of contents for SitePro 30 – 40 kVA, Serie 7 Drawing title: Drawing number: Functional Diagram UPS Assembly Layout AC Input AC Input + Rectifier Inverter / Bypass Bridges and Output Load Details for Bridges: Rectifier – Inverter - SSM AC Input with Option 5th + 11th Harmonic Filter Option: Rectifier 12 Pulses with or without Galvanic Separation 360 073 1 360 073 1 360 073 1 360 073 1 360 073 1 360 073 1 360 073 1 360 073 1 page page page page page page page page 1/8 2/8 3/8 4/8 5/8 6/8 7/8 8/8 RPA connections P340 370.0 page 1/1 Modifications reserved EDW_SPE_XXX_10K_40K_7GB_V020.doc Schematics SitePro 10-15-20-30-40 kVA INPUT BATTERY K3 H2 L1 H1 CB F1 F5,6,7 TR1 H3,4 Inverter Bridge Rectifier Bridge Q4 IM8889 IM0062 MAINS 1 5th or 5th+11th Harm.Filter L2 CP H8,9,10 Input isolation transformer U Bypass Aux.K6 Pulse Aux.Q2 MAINS 2 IM0035 SSM Bridge IM6360 IM0035 BR1-2-3: Remove only in case of separate Mains 1-2 or Mains Filter INPUT AC CONNECTIONS Remove in case of input isolation transf. I Rectifier Pulse U Rectifier IM6360 I Battery U Battery IM0035 IM0035 Pulse Inverter t° I Inv.bridge K7 On Aux.K7 I Inverter Aux.Fuses U Inverter IM6360 IM0035 IM0035 RPA Board IM0086 I Load U Load Aux.Q1 K6 Q2 All rights for trasmission, duplicating or reprinting reserved F8 F9 N K7 IM0035 28.07.05 RELEASE OPTION (Standard for Chinese UPS) Bus connection see drawing Code P340370 IM0035 H5,6,7 Q1 Page 1 of Pages 7 360213 Status Date Revision Date MAIN CONTROL BOARD IM0007 Code 7M SERIES FUNCTIONAL DIAGRAM Revision M FAN UPS IM6389 or 8889 OUTPUT LOAD REPLACE Serie 7 SitePRO 10-15-20 kVA Class A GE Digital Energy 21.06.05 02.06.2005 f.luchetta RECTIFIER see page 6 D.C. see page 4 INVERTER see page 6 Electronic BYPASS see page 5-6 g Checked by Luchetta Drawed by 5 6 7 8 1 2 3 4 OFF ON OFF ON OFF ON FRONT VIEW Sect.A-A P7 A SIDE VIEW M2 P8 P9 P10 FRONT VIEW P5 GT1-2-3 KT1 F1 CB T1 CP P4 H8-9-10 P35 K7 GT5-6-7 M1 H4 X30 P6 M1 F5F6F7 H6 H5 H7 H3 P18 P17 P40 P30 P1 H2 T2 P14 F20 H1 X10 T3 K6 TR2 P4 P3 L2 L1 Opt. P11 P13 L1 P6 P34 Q1 Q2 P2 PA Q4 TR1 Opt.J11 P23 F50 F8 F9 P1 P2 P3 P4/1 P4/2 P5 P6 P7 10 15 20 1 2 3 4 Revision P29 X1 XA IM0035- Power Interface IM0076- Power Supply IM0007- Main Control IM0005- Customer Interface IM0005- 2th OPT.Customer Interf. IM0017- Panel Board IM0004- Back Plane IM6360- Driver Power Bridges L1 kVA Typ RECT. A 26 / 31 39 / 47 52 / 62 Date TP-B-804 TP-B-799 TP-B-806 TP-B-801 Drawed by Revision P8..10 P11 P13 P14 P17..22 P23 P29 OPT.INPUT TRANSFORM. TR101/Dny11 TR101/Dd0 BP-B-1068 BP-B-1069 5 6 7 8 TR1 Side view Electronic Bracket Date f.luchetta TYPE and FUNCTION of BOARD IM6381- Rectif.Snubber IM0024- Opt.RS232 Galv. sep. IM0086- RPA Board IM6382- Bypass Snubber IM0023- Lem Protector IM8889- Interface Suppressor IM0062- Interface Suppressor L2 TR1 F 1 F 5-6-7 A A ET7500 TP-F-973 200 63 02.06.2005 CB uF Cabinet area for: - Battery or - Input isolat.transf. or - 5th/11th Harmonic filter IM0025- OPT.SNMP Card IM0048- Bus Interface IM0046- Minimal Load for SSM IM0041- OPT.Filter Control board P30 P34 P40 P50 CP uF 3x2200 3x150 GT1...6 A T1-2-3 A 90 150 H1-2-12 H3-4 H8-9-10 A A A 100 Checked by Luchetta 21.06.05 UPS ASSEMBLY LAYOUT Status 28.07.05 All rights for trasmission, duplicating or reprinting reserved RELEASE A 200 100 g H5-6-7 A 25/0,2 50/0,2 K6-7 Q1-2 Ith:A A Q4 A 32 40 1000 40 GE Digital Energy M1 mc/h M2 F8,9 mc/h (A) Shortening of cable color G: Grey Y: Yellow Br: Brown G/Y: Green/Yellow Bl: Black W: White Lb: LightBlue V: Violet R: Red Gr: Green B: Blue 40 63 SitePRO 10-15-20 kVA Class A REPLACE Serie 7 SERIES 7M Code 360213 Page 2 of Pages 7 L1-2 L2-2 L3-2 OFF ON Q4 MAINS 1 Input Rectifier Mains 2 page 4-5 MAINS 2 Input Bypass L1-2 L2-2 L3-2 BR1 BR2 BR3 To remove only in case of separate Mains 1 - 2 L1 L2 L3 See table L1 L1-1 L2-1 L3-1 1U1 1U2 1V1 1V2 1W1 1W2 - See details l in case of “Input Special transformer” E1 E2 X2 E3 BR4 L1-1 L2-1 L3-1 L1-3 L2-3 L3-3 E5 N1 See table MAINS 2 Input Bypass MAINS MAINS BRIDGE CONNECTIONS BR 1-2-3 See table SEPARATE MAINS 1-2 MAINS BRIDGE BR 1-2-3 MAINS CONNECTIONS RECTIFIER Connect in X1 : L1-2-3/3 L1-2-3/3 ON L1-2-3/2 OFF Mains1:L1-2-3/3 Mains2:L1-2-3/2 BYPASS Connect in X1 : L1-2-3/2 ON L1-2-3/1 L1-2-3/2 OFF Mains1:L1-2-3/1 Mains2:L1-2-3/2 MAINS 1 Input Rectifier 2V 1W 2W PE N Drawed by Date Luchetta 02.06.2005 Checked by Luchetta 21.06.05 AC INPUT Status 28.07.05 All rights for trasmission, duplicating or reprinting reserved RELEASE 1U 2U 1V 2V 1W 2W g N connect N to PE L1-1 L2-1 L3-1 L1 to Q4 (page 4) or L2 L3 Harm.Filter (page 7) L1 L2 L3 L1-3 L2-3 L3-3 L1 L1 L1 L2 L2 L2 L3 L3 L3 1 2 3 1 2 3 1 2 3 Revision 1V BR1 BR2 BR3 Special Transformer for.. Date 2U PE COMMON MAINS 1-2 Revision to Q4 (page 4) or Harm.Filter (page 7) 1U L1-2 L2-2 L3-2 TABLE for MAINS CONNECTIONS 5 6 7 8 to K6 (page 5) INPUT TRANSFORMER for RECTIFIER INPUT TRANSFORMER for BYPASS PE 1 2 3 4 L1 L2 L3 BR3 BR2 BR1 N2 (page 4) U Rectif. P1 E4 L3 MAINS 1 Input Rectifier To Rectifier Bridge 1 2 3 P23 L2 see page 7 OPTION 5th/11th Harm. Filter To X10-4 (pag.5) - See page 7 in case of 5th Harmonic filter L1 L1 L2 L3 BR1 BR2 BR3 MAINS 2 Input Bypass to K6 (page 5) Move from L1,2,3-2 to >>> L1,2,3-3 GE Digital Energy SitePRO 10-15-20 kVA Class A REPLACE Serie 7 SERIES 7M Code 360213 Page 3 of Pages 7 L1-2 L2-2 L3-2 L2-1 L3-1 1U2 1V1 1V2 1W1 1W2 2x27KW 10W GT3 L1 1U1 L1-1 J22 To Inverter bridge CB R1 (page 5) H1 To X10-4 (pag.5) P23 J17 1Wdg E9 E4 BR4 P7 J212 see page 7 OPTION 5th or 5th+11th Harm. Filter X2-1 X2-2 X2-3 E1 E2 E3 N2 F1 (Details see pg.6) GT2 Q4 MAINS 1 Input Rectifier RECTIFIER BRIDGE OFF ON GT1 To remove only in case of separate Mains 1 - 2 L1 Mains 2 L2 (page 5) L3 BR1 BR2 BR3 MAINS 2 Input Bypass E5 N1 N2 PE PE H2 F8 INPUT BATTERY L2 X1-2 J28-2 J28-1 LD1 X1-1 OPT. K3 see detail F9 J23-5 J23-6 2 Wdg P30 OPT. To see pg.8 J28-2 To see pg.8 J28-1 J14-4 J14-5 A1 A2 J11 J5 1 Wdg J11 Opt. X2 J34 P1 J28 J14 J23 J25 J26 X1 J5 J7 J5 J10 J10 X8 J9 J6 J8 P2 J1 J5 J17 P3 J13 J18 J22 J52 J62 J34-2 J34-1 C1 P13 J21 J1 P6 J6 J3 J2 P5 + P11 OPT. X1 P4 TR2 LCD 20x4 J21 To P32 (see Sch. P340370) 1 2 3 4 Revision Date 5 6 7 8 Drawed by Revision Date f.luchetta 02.06.2005 Checked by Luchetta 21.06.05 AC INPUT + RECTIFIER Status 28.07.05 All rights for trasmission, duplicating or reprinting reserved RELEASE g GE Digital Energy SitePRO 10-15-20 kVA Class A REPLACE Serie 7 SERIES 7M Code 360213 Page 4 of Pages 7 OFF ON Q2 MAINS 2 L1 Input L2 Bypass L3 SSM BRIDGE A1 To X10-1 P7 J112 J 2 A2 E8 E7 E6 2 Wdg INVERTER BRIDGE 1W 2W J23-1 J23-2 P7 J12 H8 1 H10 4 H6 1 A1 A2 CP J23-3 J23-4 J19 Q1 H5 P40 H9 X7-2 X7-1 JF1 JF2 JF3 JF4 JF9 JF8 JF7 -4 JF5 JF6 E1 E2 4 H7 1 E3 4 22W/ 0,6W J35-2 J35-3 J35-4 J35-5 J35-6 2V J35-1 2U 1V X4-1 X4-2 X4-3 1U T3 T2 T1 H4 X4-4 X4-5 X4-6 H3 OFF ON K7 J28-3 J28-4 F5-6-7 P23 (Details see pg.6) TR1 E11 E10 J6-2 J6-1 J28-5 J28-6 X3-1 X3-2 X3-3 (Details see pg.6) F50-2A 1 XA 2 To X10-2 X3 P29 E4 N1 M2 PE M1 Lb Br Bl X5-1 X5-2 PA P30 OPT. from H12 (pg.8) 1 Wdg From Q4-Aux. (page 3) X4 P1 X5 X3 J6 J23 X7 J35 J28 J4 J1 J4 J10 J10 X8 J9 J4 P2 2 Wdg J19 P3 J33 P19 J2 P20 J2 J36 J37 P21 J2 J38 J52 J62 12345 To P23-E11 To P40-JF6 P13 J5 P22 J2 J11 Opt. J35 J1 Revision Date Drawed by Revision Date f.luchetta 02.06.2005 Checked by Luchetta 21.06.05 Status 28.07.05 RELEASE INVERTER/BYPASS BRIDGES and OUTPUT LOAD All rights for trasmission, duplicating or reprinting reserved g GE Digital Energy SitePRO 10-15-20 kVA Class A P6 J6 J3 J2 P5 + X1 P11 Opt. P4 TR2 5 6 7 8 XB OPTION J11 X10 see pag.7-8 12 N L 1 2 3 4 5 X30 1 2 3 4 N2 150 nF PE L1 L2 L3 OUTPUT LOAD K6 LCD 20x4 J8 REPLACE Serie 7 SERIES 7M Code 360213 Page 5 of Pages 7 F1 L1 From Choke Coil L1 (pg.3-4) P9 P10 T1 GT1 k1 2 GT2 k1 2 GT3 k1 2 g1 g1 g1 1 To P3-J22 (pg. 4) 1 L2 To CB (pg. 4) 1 L3 k2 k2 3 g2 T3 G1 E1 From CB (pg. 4) C9 0,68uF 630V= G2 3 g2 G2 G2 E2 E2 H4 J 212 J 17 J2 KT1- NTC 80° 33nF/ 500V L1 From K6 (pg. 5) 2 E3 L2 33/6W 2 k1 33/6W 2 k1 g1 33nF/ 500V g1 33nF/ 500V g1 1 1 E1 L2 k2 k2 3 g2 1 E4 E6 L3 L1 L3 k2 E9 Drawed by Revision Date f.luchetta 12 45 J110 J101 P7 E7 J12 J19 P2-J 1 (pg.5) P3-J19 (pg.5) J102 J2 B R Bl 12 45 J111 P3-J33 (pg.5) 02.06.2005 Checked by Luchetta 21.06.05 Status 28.07.05 RELEASE G B R Bl G R Bl G B J112 P2-J 4 (pg.5) SSM Date J21 INVERTER P7 Revision J100 3 g2 3 g2 12 45 J109 5 6 7 8 J20 To K7/Q1 (pg. 5) P14 1 2 3 4 4 5 1 2 k1 4 3 2 1 GT7 4 5 1 2 33/6W GT6 4 3 2 1 GT5 To TR1 (pg. 5) G Bl R B P18 J2 G Bl R B P17 JF4 RECTIFIER L1 L2 L3 P3-J17 (pg.4) JF3 P2-J 5 (pg.4) G Bl R B P7 21 54 J120 4 3 2 1 21 54 J118 4 3 2 1 H3 21 54 J116 C11 0,68uF 630V= Bl G B R Bl G B R Bl G B E1 C10 0,68uF 630V= E2 R G1 E1 k2 3 g2 T2 G1 4 5 1 2 P8 DETAILS FOR BRIDGES: RECTIFIER-INVERTER-SSM All rights for trasmission, duplicating or reprinting reserved g GE Digital Energy SitePRO 10-15-20 kVA Class A REPLACE Serie 7 SERIES 7M Code 360213 Page 6 of Pages 7 UPS 5th or 5th+11th HARM.FILTER L50 1U1 1U2 R 1V1 1V2 1V1 1V2 R 1W1 1W2 1W1 1W2 R H101 1 ** A1 C50 A2 F110 **: 10-15kVA : 2 20-30kVA : 3 40kVA :4 OFF ON L1-1 L1 L2-1 L2 L3-1 L3 1 2 3 4 X2 L2-3 1U1 1U2 1V1 1V2 R 1W1 1W2 R (page 4) X2 1 2 3 4 X10 X10 1 2 3 4 5 1 2 3 4 5 123456 X3 123456 X2 P50 IM0041 1.to remove from P1 2.to insert on P1 P1 L3-3 X1 JF1 JF2 1234 GEN.ON from Customer GEN.ON to UPS U Rectif. E1 E2 R=120K/2W R To Choke Coil L1 to see pag.5 L1-3 C110 L110 X4 123456 Q4 MAINS 1 Input F50 1U2 BR1 BR2 BR3 To remove only in case of separate Mains 1 - 2 L1 L2 L3 page 4-5 L1-2 L2-2 L3-2 Mains 2 MAINS 2 Input Bypass K50 L101 1U1 E3 P23 E4 5th HARM.FILTER E5 kVA 10 15 N1 BR4 N2 20 F50 C50 14X51 3X32AgG 14X51 3X40AgG L101 L50 50Hz. BP-B-790 3x2,58mH BP-B-768 17A 3x4,069mH 13A BP-B-791 3x1,29mH BP-B-769 34A 3x 3x2,035mH 200uF 25A 3x 100uF 11th HARM.FILTER L50 60Hz. F110 L110 L110 50Hz. 60Hz. BP-B-779 3x2,826mH 10x38 BP-B-1062 15A 3X20AgG 3x836uH 30 A C110 Setting P50 for insert.Filter 7A 3x 100uF BP-B-780 3x1,413mH 30A 10 A 15 A PE 1 2 3 4 Revision Date 5 6 7 8 Drawed by Revision Date f.luchetta 02.06.2005 Checked by Luchetta 21.06.05 Status 28.07.05 RELEASE AC INPUT with Option 5th+11th Harmonic FILTER All rights for trasmission, duplicating or reprinting reserved g GE Digital Energy SitePRO 10-15-20 kVA Class A REPLACE Serie 7 SERIES 7M Code 360213 Page 7 of Pages 7 L3 TR101 L1 Rectifier Bridge 2 F8 L3 TR101 H2 Rectifier Bridge 2 H12 K3 L1 H1 CB F1 F5,6,7 TR1 H3,4 Inverter Bridge Rectifier Bridge Q4 IM6389 MAINS 1 5th or 5th+11th Harm.Filter L2 CP H8,9,10 Input isolation transformer U Bypass Aux.K6 Pulse Aux.Q2 MAINS 2 IM0035 SSM Bridge IM6360 IM0035 BR1-2-3: Remove only in case of separate Mains 1-2 or Mains Filter INPUT AC CONNECTIONS I Rectifier Pulse U Rectifier Remove in case of input isolation transf. IM0035 IM6360 I Battery U Battery Remove only in case of 12P Rectifier IM0035 Pulse Inverter t° I Inv.bridge K7 On Aux.K7 I Inverter Aux.Fuses U Inverter IM6360 IM0035 IM0035 RPA Board IM0006 I Load U Load Aux.Q1 K6 Q2 All rights for trasmission, duplicating or reprinting reserved H12 INPUT BATTERY F9 OPTION (Standard for Chinese UPS) N K7 IM0035 IM0035 10.05.05 ECN 829 12 P Rectifier with Galvanic Separat. Bus connection see drawing Code P340370 M H5,6,7 Q1 Page 1 of Pages 8 3600731 Status Date MAIN CONTROL BOARD IM0007 Code 7 SERIES FUNCTIONAL DIAGRAM L1 FAN UPS IM6389 or 8889 OUTPUT LOAD REPLACE Serie 6G SitePRO 30-40 kVA GE Digital Energy 02.05.05 24.09.2004 f.luchetta 02.05.05 5 6 7 8 Revision Date Revision RECTIFIER see page 6 D.C. see page 4 INVERTER see page 6 Electronic BYPASS see page 5-6 g Checked by Luchetta Drawed by 829 1 2 3 4 OFF ON OFF ON OFF ON 12 P Rectifier w/o Galvanic Separat. FRONT VIEW Sect.A-A P7 A SIDE VIEW M2 P8 P9 P10 FRONT VIEW P5 GT1-2-3 KT1 F1 CB T1 CP P4 H8-9-10 P35 K7 H4 Opt. X12 M1 P6 X30 M1 F5F6F7 H6 H5 H7 H3 P18 P17 P40 GT5-6-7 P30 P1 H2 T2 P14 F20 H1 X10 T3 K6 TR2 P4 P3 L2 L1 Opt. P11 P13 L1 P6 P34 Q1 Q2 PA XB F5 Q4 P2 TR1 Opt.J11 P23 F8 F9 P1 P2 P3 P4/1 P4/2 P5 P6 P7 30 40 1 2 3 4 829 Revision X1 IM0035- Power Interface IM0076- Power Supply IM0007- Main Control IM0005- Customer Interface IM0005- 2th OPT.Customer Interf. IM0017- Panel Board IM0004- Back Plane IM6360- Driver Power Bridges L1 kVA Typ RECT. A P8..10 P11 P13 P14 P17..22 P23 OPT.INPUT TRANSFORM. TR101/Dny11 TR101/Dd0 TYPE and FUNCTION of BOARD IM6381- Rectif.Snubber IM0024- Opt.RS232 Galv. sep. IM0086- RPA Board IM6382- Bypass Snubber IM0023- Lem Protector IM6389- Interface Suppressor L2 TR1 F 1 F 5-6-7 A A CB uF Cabinet area for: - Battery or - Input isolat.transf. or - 5th/11th Harmonic filter Date 5 6 7 8 Drawed by Revision Date f.luchetta 24.09.2004 CP uF GT1...6 A T1-2-3 A 90 300 H1-2-12 H3-4 H8-9-10 A A A 200 Checked by Luchetta 02.05.05 UPS ASSEMBLY LAYOUT Status 10.05.05 All rights for trasmission, duplicating or reprinting reserved ECN 829 A IM6343- 2th OPT.12 P.Rectif.Driver IM0025- OPT.SNMP Card IM0048- Bus Interface IM0046- Minimal Load for SSM IM0041- Filter Control board P25 P30 P34 P40 P50 77 / 92 BP-B-1071** TP-B-807 TP-B-802 ET7399 TP-F-975 315 100 5x2200 3x250 TP-B-808 TP-B-803 90 / 108 ** remove for 12 P Rectifier (see pg.8) 02.05.05 TR1 Side view Electronic Bracket 400 200 g H5-6-7 A 100/0,2 K6-7 Q1-2 Ith:A A 60 63 GE Digital Energy Q4 A M1 mc/h Shortening of cable color G: Grey Y: Yellow Br: Brown G/Y: Green/Yellow Bl: Black W: White Lb: LightBlue V: Violet R: Red Gr: Green B: Blue M2 F8,9 mc/h (A) 80 1000 150 100 SitePRO 30-40 kVA REPLACE Serie 6G SERIES 7 Code 3600731 Page 2 of Pages 8 L1-2 L2-2 L3-2 X12 BR1 BR2 BR3 To remove only in case of separate Mains 1 - 2 L1 L2 L3 OFF ON Q4 MAINS 1 Input Rectifier L1 L1-1 L2-1 L3-1 see page 8 OPT.12 P Rectifier (only for 40kVA) 1Wdg 1U1 1U2 1V1 1V2 1W1 1W2 - See details l in case of “Input Special transformer” E1 E2 X2 E3 BR4 See table L1 L2 L3 MAINS 1 Input Rectifier To Rectifier Bridge (page 4) L1-1 L2-1 L3-1 L2-3 L3-3 E5 N1 See table MAINS 2 Input Bypass Special Transformer for.. MAINS MAINS BRIDGE CONNECTIONS BR 1-2-3 Date MAINS BRIDGE BR 1-2-3 MAINS CONNECTIONS RECTIFIER Connect in X1 : L1-2-3/3 L1-2-3/3 ON L1-2-3/2 OFF Mains1:L1-2-3/3 Mains2:L1-2-3/2 BYPASS Connect in X1 : L1-2-3/2 ON L1-2-3/1 L1-2-3/2 OFF Mains1:L1-2-3/1 Mains2:L1-2-3/2 Drawed by Revision Date 1V 2V 1W 2W PE N Luchetta 24.09.2004 Checked by Luchetta 02.05.2005 Status 10.05.05 ECN 629 1U 2U 1V 2V 1W 2W BR1 BR2 BR3 See table SEPARATE MAINS 1-2 MAINS 1 Input Rectifier AC INPUT All rights for trasmission, duplicating or reprinting reserved g N connect N to PE L1-1 L2-1 L3-1 L1 to Q4 (page 4) or L2 L3 Harm.Filter (page 7) L1 L2 L3 L1-3 L2-3 L3-3 L1 L1 L1 L2 L2 L2 L3 L3 L3 1 2 3 1 2 3 1 2 3 Revision 2U PE COMMON MAINS 1-2 5 6 7 8 to Q4 (page 4) or Harm.Filter (page 7) 1U L1-2 L2-2 L3-2 TABLE for MAINS CONNECTIONS 02.05.05 to K6 (page 5) INPUT TRANSFORMER for RECTIFIER INPUT TRANSFORMER for BYPASS PE 829 L1 L2 L3 L1-3 33nF 1 2 3 4 L1 L2 L3 BR3 BR2 BR1 N2 L1-2 L2-2 L3-2 X12 U Rectif. P1 E4 MAINS 2 Input Bypass 1 2 3 P23 page 4-5 see page 7 OPTION 5th/11th Harm. Filter To X10-4 (pag.5) - See page 7 in case of 5th Harmonic filter Mains 2 BR1 BR2 BR3 MAINS 2 Input Bypass to K6 (page 5) Move from L1,2,3-2 to >>> L1,2,3-3 GE Digital Energy SitePRO 30-40 kVA REPLACE Serie 6G SERIES 7 Code 3600731 Page 3 of Pages 8 L1-2 L2-2 L3-2 L3-1 1Wdg 1U2 1V1 1V2 1W1 1W2 To Inverter bridge (page 5) P7 J212 J17 1Wdg E9 E4 PE J22 CB R1 see page 7 OPTION 5th or 5th+11th Harm. Filter X2-1 X2-2 X2-3 E1 E2 E3 N2 2x27KW 10W H1 To X10-4 (pag.5) P23 F1 (Details see pg.6) GT3 L2-1 RECTIFIER BRIDGE GT2 L1 1U1 L1-1 X12 GT1 OFF ON Q4 MAINS 1 Input Rectifier see page 8 OPT.12 P Rectifier (only for 40kVA) X12 E5 N1 BR4 N2 33nF PE H2 F8 INPUT BATTERY L2 J28-2 J28-1 LD1 X1-1 OPT. K3 see detail F9 X1-2 To remove only in case of separate Mains 1 - 2 L1 Mains 2 L2 (page 5) L3 BR1 BR2 BR3 MAINS 2 Input Bypass J23-5 J23-6 2 Wdg P30 OPT. To see pg.8 J28-2 To see pg.8 J28-1 J14-4 J14-5 A1 A2 J11 J5 1 Wdg J11 Opt. X2 J34 P1 J28 J14 J23 J25 J26 X1 J5 J7 J5 J10 J10 X8 J9 J6 J8 P2 J1 J5 J17 P3 J13 J18 J22 J52 J62 J34-2 J34-1 C1 P13 J21 J1 P6 J6 J3 J2 P5 + P11 OPT. X1 P4 TR2 LCD 20x4 J21 To P32 (see Sch. P340370) 1 2 3 4 829 02.05.05 5 6 7 8 Revision Date Revision Drawed by Date f.luchetta 24.09.2004 Checked by Luchetta 02.05.2005 Status 10.05.05 ECN 829 AC INPUT + RECTIFIER All rights for trasmission, duplicating or reprinting reserved g GE Digital Energy SitePRO 30-40 kVA REPLACE Serie 6G SERIES 7 Code 3600731 Page 4 of Pages 8 OFF ON Q2 MAINS 2 L1 Input L2 Bypass L3 SSM BRIDGE K6 J28-5 J28-6 X3-1 X3-2 X3-3 (Details see pg.6) J6-2 J6-1 1Wdg A1 A2 P7 J112 J 2 3x47nF 2 Wdg INVERTER BRIDGE (Details see pg.6) J23-1 J23-2 P7 J12 1 H10 A1 A2 X7-2 X7-1 JF1 JF2 JF3 JF4 JF5 JF6 JF9 JF8 JF7 L1 L2 L3 4 H6 1 CP J23-3 J23-4 J19 Q1 H5 P40 4 H7 1 4 22W/ 0,6W E8 E7 E6 P23 -4 To X10-2 X3 OUTPUT LOAD 1W 2W H8 H9 J35-2 J35-3 J35-4 J35-5 J35-6 2V J35-1 2U 1V X4-1 X4-2 X4-3 1U T3 T2 T1 H4 X4-4 X4-5 X4-6 H3 OFF ON K7 J28-3 J28-4 F5-6-7 TR1 E11 E10 To X10-1 1Wdg N2 N1 PE M2 L M1 Lb F50 2A Br XB3 Bl X5-1 X5-2 PA P30 OPT. from H12 (pg.8) From Q4-Aux. (page 3) X4 P1 X5 X3 J6 J23 X7 J35 J28 J4 J1 J4 J10 J10 X8 J9 J4 P2 P19 J2 2 Wdg J19 P3 J33 P20 J2 J36 J37 P21 J2 J38 J52 J62 12345 1 Wdg P13 J5 P22 J2 J11 Opt. J35 829 Revision 02.05.05 Date 5 6 7 8 Drawed by Revision Date f.luchetta 24.09.2004 Checked by Luchetta 02.05.2005 Status 10.05.05 ECN 829 INVERTER/BYPASS BRIDGES and OUTPUT LOAD All rights for trasmission, duplicating or reprinting reserved g GE Digital Energy SitePRO 30-40 kVA J1 P6 J6 J3 J2 P5 + X1 P11 Opt. P4 TR2 1 2 3 4 XB OPTION J11 X10 To P23-E11 To P40-JF6 12 N L 1 2 3 4 5 X30 see pag.7-8 PE N LCD 20x4 J8 REPLACE Serie 6G SERIES 7 Code 3600731 Page 5 of Pages 8 F1 From Choke Coil L1 (pg.3-4) L1 P9 P10 T1 GT1 k1 2 GT2 k1 2 GT3 k1 2 g1 g1 g1 1 To P3-J22 (pg. 4) 1 L2 To CB (pg. 4) 1 L3 k2 k2 3 g2 T3 G1 E1 From CB (pg. 4) C9 0,68uF 630V= G2 3 g2 G2 G2 E2 E2 H4 J212 J 17 J2 KT1- NTC 80° From K6 (pg. 5) L1 L2 2 33nF/ 500V E3 33/6W 2 k1 33/6W 2 k1 g1 33nF/ 500V g1 33nF/ 500V g1 1 1 E1 L2 k2 k2 3 g2 1 E4 E6 L3 L1 L3 k2 E9 J100 J21 J101 P7 E7 J12 J19 P2-J 1 (pg.5) P3-J19 (pg.5) J102 3 g2 3 g2 INVERTER P7 J112 12 45 J110 P2-J 4 (pg.5) SSM 829 Drawed by Date J2 B R Bl 12 45 J111 P3-J33 (pg.5) f.luchetta 24.09.2004 Checked by Luchetta 02.05.2005 Status 10.05.05 ECN 829 G B R Bl G B R Bl G 12 45 J109 02.05.05 5 6 7 8 Revision Date Revision J20 To K7/Q1 (pg. 5) P14 1 2 3 4 4 5 1 2 k1 4 3 2 1 GT7 4 5 1 2 33/6W GT6 4 3 2 1 GT5 To TR1 (pg. 5) G Bl R B P18 J2 G Bl R B P17 JF4 RECTIFIER L1 L2 L3 P3-J17 (pg.4) JF3 P2-J 5 (pg.4) G Bl R B P7 21 54 J120 4 3 2 1 21 54 J118 4 3 2 1 H3 21 54 J116 C11 0,68uF 630V= Bl G B R Bl G B R Bl G B E1 C10 0,68uF 630V= E2 R G1 E1 k2 3 g2 T2 G1 4 5 1 2 P8 DETAILS FOR BRIDGES: RECTIFIER-INVERTER-SSM All rights for trasmission, duplicating or reprinting reserved g GE Digital Energy SitePRO 30-40 kVA REPLACE Serie 6G SERIES 7 Code 3600731 Page 6 of Pages 8 UPS 5th or 5th+11th HARM.FILTER L50 1U1 1U2 R 1V1 1V2 1V1 1V2 R 1W1 1W2 1W1 1W2 R H101 1 ** A1 C50 A2 F110 **: 10-15kVA : 2 20-30kVA : 3 40kVA :4 OFF ON L1-1 L1 L2-1 L2 L3-1 L3 1 2 3 4 L2-3 X2 1 2 3 4 X10 X10 1 2 3 4 5 1 2 3 4 5 123456 X3 1U2 1V1 1V2 R 1W1 1W2 R 123456 X2 P50 IM0041 1.to remove from P1 2.to insert on P1 P1 L3-3 1U1 (page 4) 1Wdg X2 X1 JF1 JF2 1234 GEN.ON from Customer GEN.ON to UPS U Rectif. E1 E2 R=120K/2W R To Choke Coil L1 to see pag.5 L1-3 C110 L110 X4 123456 Q4 MAINS 1 Input F50 1U2 BR1 BR2 BR3 To remove only in case of separate Mains 1 - 2 L1 L2 L3 page 4-5 L1-2 L2-2 L3-2 Mains 2 MAINS 2 Input Bypass K50 L101 1U1 E3 P23 E4 E5 5th HARM.FILTER kVA N1 BR4 N2 PE 1 2 3 4 829 Revision 02.05.05 Date 5 6 7 8 Drawed by Revision Date f.luchetta 24.09.2004 Checked by Luchetta 02.05.2005 Status 10.05.05 ECN 829 AC INPUT with Option 5th+11th Harmonic FILTER All rights for trasmission, duplicating or reprinting reserved F50 C50 30 14X51 3X40AgG 40 14X51 3X50AgG g L101 11th HARM.FILTER L50 50Hz. L50 60Hz. F110 L110 L110 50Hz. 60Hz. BP-B-792 BP-B-769 BP-B-780 3x860uH 3x2,035mH 3x1,413mH 3x 10x38 BP-B-1062 51A 25A 30A 200uF 3X20AgG 3x836uH 3 x BP-B-793 BP-B-770 BP-B-781 30 A 250uF 3x650uH 3x1,63mH 3x1,132mH 68A 35A 40A GE Digital Energy SitePRO 30-40 kVA C110 Setting P50 for insert.Filter 3x 100uF 20 A 25 A REPLACE Serie 6G SERIES 7 Code 3600731 Page 7 of Pages 8 TR101 1U 1V 2 3 2U 1U1 2V 1V1 2W 1W1 1U2 1V2 4 1W2 5 L1 To (page 4) L3 6 3W 2 L3 N in UPS Cabinet From Q4 Out (page3-4) 1U1 1U2 L1 1V1 1V2 L2 1W1 1W2 L3 GT7 k1 2 GT8 k1 g1 L3 TR101 L1=L3 TP-B-809 BP-B-791 TR101 L3 L1 TP-B-806 BP-B-791 BP-B-1069 1U1 L1 1U2 1V2 4 1W1 1W2 5 6 1U TR101 2U 1V 1W 2 3 Lb Br Revision Date H12 5 4 3 2 1 1 2 3 4 5 X32 2 GT7 k1 2V 1V1 1V2 L2 1W1 1W2 L3 2 GT8 k1 g1 L1 1U2 2 To CB (pag.4) GT9 k1 g1 1 g1 To P22 (page 5) 1 1 k2 k2 3 g2 k2 3 g2 3 g2 in UPS Cabinet 45 12 J100 P 25 Rectifier Bridge 2 1 2 3 4 X10 Bl To X12 1U1 1V1 1W1 From Q4 (page3-4) P3-J18 (pg.4) L2 RECTIFIER BRIDGE 1 (page 4) L3 2W N Br 1 2 3 4 5 X20 L1 12 45 J104 J 17 M5 Bl in UPS Cabinet L3 1U1 12 45 J102 J 12 X12 1V1 3 g2 P2-J 6 (pg.4) M20 WITHOUT GALVANIC SEPARATION To P22 (page 5) k2 3 g2 Rectifier Bridge 2 Lb 1 k2 12 45 J100 P 25 P25 TR101 g1 1 3 g2 M5 GT9 k1 1 WITH GALVANIC SEPARATION L1 2 g1 1 k2 M20 To CB (pag.4) L2 RECTIFIER BRIDGE 1 in UPS Cabinet 3V X12 L1 L2 L3 X12 3U 1W 1 H12 L1 5 6 7 8 Drawed by Checked by Revision Date Status f.luchetta 24.09.2004 27.09.2004 RELEASE 27.09.2004 Options: Rectifier 12 Pulses with or w/o Galvanic Separation All rights for trasmission, duplicating or reprinting reserved g P 25 J 12 45 12 J102 P2-J 6 (pg.4) GE Digital Energy SitePRO only 40 kVA 45 12 J104 J 17 P3-J18 (pg.4) REPLACE Serie 6G SERIES 7 Code 3600731 Page 8 of Pages 8 3 UPS with RPA System 4 UPS with RPA System P13 P13 P13 P13 P13 P13 J62 J52 J62 J52 J62 J52 J62 J52 J62 J52 J62 J52 Jumper JP1..4: ON Jumper JP1..4: ON Jumper JP1..4: OFF Jumper JP1..4: ON Jumper JP1..4: ON Jumper JP1..4: OFF 5 UPS with RPA System JP2 JB IM0048 JB1 JB2 JA1 JA2 JA JP3 JP2 JP3 JB IM0048 JB1 JB2 JA1 JA2 JA JP1 JP4 JP2 JP3 JB IM0048 JB1 JB2 JA1 JA2 JA JP1 JP4 JP2 JP3 JB IM0048 JB1 JB2 JA1 JA2 JA JP1 JP4 JP2 JP3 JB IM0048 JB1 JB2 JA1 JA2 JA JP1 JP4 IM0048 JP2 JB JP3 JP1 JP4 JP2 IM0048 JB1 JB2 JA1 JA2 JA JB1 JB2 JA1 JA2 Jumper JP1..4: OFF JB1 JB2 JA1 JA2 Jumper JP1..4: ON 6 UPS with RPA System P13 P13 P13 P13 P13 P13 P13 J62 J52 J62 J52 J62 J52 J62 J52 J62 J52 J62 J52 J62 J52 Jumper JP1..4: ON Jumper JP1..4: OFF Jumper JP1..4: OFF Jumper JP1..4: OFF Jumper JP1..4: ON Jumper JP1..4: ON Jumper JP1..4: OFF Jumper JP1..4: OFF Jumper JP1..4: OFF JB1 JB2 JA1 JA2 Jumper JP1..4: OFF JB JP2 JP3 JA IM0048 JB1 JB2 JA1 JA2 JB JP2 JP3 JP1 JP4 JA IM0048 JB1 JB2 JA1 JA2 JB JP2 JP3 JP1 JP4 JP2 JA IM0048 JB1 JB2 JA1 JA2 JB IM0048 JP3 JA JP1 JP4 JP2 JP3 JB1 JB2 JA1 JA2 JB IM0048 JP2 JP3 JP1 JP4 JB1 JB2 JA1 JA2 JA JP1 JP4 JB JA IM0048 JB1 JB2 JA1 JA2 JB JP2 JP3 JP1 JP4 JA IM0048 JB1 JB2 JA1 JA2 JB JP2 JP3 JP1 JP4 JP2 JA IM0048 JB1 JB2 JA1 JA2 JB IM0048 JA JP3 JP2 JP3 JB1 JB2 JA1 JA2 JB IM0048 JP2 IM0048 JA JP1 JP4 P13 J62 J52 JP1 JP4 P13 J62 J52 JP1 JP4 P13 J62 J52 JP1 JP4 P13 J62 J52 JB JA JA JP3 Jumper JP1..4: ON JP3 IM0048 JB1 JB2 JA1 JA2 JB JA JP1 JP4 JB JP2 JA JP3 IM0048 JP2 JB JP1 JP4 P13 J62 J52 JP1 JP4 P13 J62 J52 JP1 JP4 P13 J62 J52 JP3 2 UPS with RPA System JB1 JB2 JA1 JA2 Jumper JP1..4: ON 7 UPS with RPA System P13 P13 P13 P13 P13 P13 J62 J52 J62 J52 J62 J52 J62 J52 J62 J52 J62 J52 Jumper JP1..4: ON Jumper JP1..4: OFF Jumper JP1..4: OFF Jumper JP1..4: OFF Jumper JP1..4: OFF JB1 JB2 JA1 JA2 Jumper JP1..4: OFF JA JP1 JP4 JB JP2 JP3 JP1 JP4 JA IM0048 JB1 JB2 JA1 JA2 JB JP2 JP3 JP1 JP4 JA IM0048 JB1 JB2 JA1 JA2 JB JP2 JP3 JP1 JP4 JA IM0048 JB1 JB2 JA1 JA2 JB JP2 JP3 JP1 JP4 JA IM0048 JB1 JB2 JA1 JA2 JB JP2 JP3 JP1 JP4 JP2 JA IM0048 JB1 JB2 JA1 JA2 JB IM0048 JP3 JA JP1 JP4 IM0048 JP2 JB JP3 P13 J62 J52 JB1 JB2 JA1 JA2 Jumper JP1..4: ON 8 UPS with RPA System J62 J52 J62 J52 J62 J52 Jumper JP1..4: ON 1 2 3 4 0092 0167 23.07.01 22.06.02 01.03.04 Revision Date D.R. F.L. C.M. Name 5 6 7 8 Revision Date Name Jumper JP1..4: OFF Jumper JP1..4: OFF Date 04.03.2002 Design. f.l. Date Control Jumper JP1..4: OFF Jumper JP1..4: OFF RPA CONNECTIONS All rights for trasmission, duplicating or reprinting reserved Jumper JP1..4: OFF g JB1 JB2 JA1 JA2 Jumper JP1..4: OFF GE Digital Energy JB JP2 JP3 JA IM0048 JB1 JB2 JA1 JA2 JB JP2 JP3 JA IM0048 JB1 JB2 JA1 JA2 JB JP2 JP3 JA IM0048 JB1 JB2 JA1 JA2 JB JP2 JP3 JA IM0048 JB1 JB2 JA1 JA2 JB JP2 JP3 JA IM0048 JB1 JB2 JA1 JA2 JB JP2 JP3 JP2 JA IM0048 JB1 JB2 JA1 JA2 JB IM0048 JA JP3 IM0048 JP2 JB JA JP3 J62 J52 JP1 JP4 P13 J62 J52 JP1 JP4 P13 J62 J52 JP1 JP4 P13 J62 J52 JP1 JP4 P13 J62 J52 JP1 JP4 P13 JP1 JP4 P13 JP1 JP4 P13 JP1 JP4 P13 JB1 JB2 JA1 JA2 Jumper JP1..4: ON P13 = IM0006 or IM0086 IM0048 = P32 for SitePRO P34 for SG Series SitePRO-SG Series Valid for All UPS: S.PRO S.6G-H - S.7-7M S.PRO-A S.6G-H / SG Series with RPA SERIES Page 1 Code P340370 of Pages 1 10-500 kVA