Sizing, Installation, Dimensions And Weights Gold

   EMBED


Share

Transcript

GOLD Sizing, Installation, Dimensions and Weights The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be carried out in the ProUnit air handling unit selection program. Contents Prerequisites for Sizing...................................................................................................... 45 GOLD RX, One-piece air handling units with rotary heat exchanger............................ 46 GOLD PX, One-piece air handling units with plate heat exchanger.............................. 94 GOLD CX, One-piece air handling units with coil heat exchanger............................... 114 GOLD SD, Supply air and extract air handling units..................................................... 130 20160422 We reserve the right to alter specifications. 43 GOLD 44 We reserve the right to alter specifications. 20160422 GOLD Sizing, Installation, Dimensions and Weights Prerequisites for Sizing Fan Diagrams The SFPV diagram on the pages that follow shows the electric power efficiency rating of the air handling unit calculated according to the procedure defined by SwedVent, the Swedish Association of Air handling Industries (V Publication 1995:1, Rev. 2000). The SFPV-value is calculated according to the V publication under the load conditions that exist when the air filters are clean. GOLD RX/PX/CX The SFPV diagrams and Extract air fan are calculated with the assumption that the supply air and extract air fans have the same airflow and available total pressure rise. The leakage and purging air flow and the extra pressure drop in the extract air have been taken into consideration in order to ensure the correct direction of air leakage at a pressure ratio that corresponds to a normal installation for a certain available pressure. Acoustic calculations The sound emitted by Swegon products is measured according to the method defined in ISO 5136, the most widely used method in Europe. Acoustic measurements are sometimes taken using other methods. The total sound power level LW, tot emitted from the fan outlet to the ducting can be read from each of the fan diagrams. The following formula can be used for breaking down the total sound power level into octave bands: LW, ok = LW, tot + Kok. Kok can be obtained from tables on the pages that follow. The Extract air fan and Supply air fan diagrams indicate the available total pressure rise to cover duct pressure drop and external functional sections, and total sound power level, LW, tot emitted to a connecting outlet duct, dB (relative to 10 -12 W), in the 125 – 8,000 Hz octave band frequencies. The available pressure rise calculated for the design pressure drop across filters is specified in all the diagrams. The blue broken line defines the limits of the numbered ranges (1,2,3,4) for particulars of the correction factors KOK in a separate table. Range 1 is the most favourable range from an acoustic point of view. GOLD SD The Fan Charts indicate the total pressure rise to cover possible internal total pressure losses for, e.g. filters, duct pressure drop and external functional sections, and total sound power level LW, tot emitted to a connecting outlet duct, dB (relative to 10 -12 W), in the 125 – 8,000 Hz octave band frequencies. The total pressure loss for an optional filter (all sizes), coil heat exchanger and droplet eliminator (sizes 14-80) are specified in the lower chart. The blue broken line defines the limits of the numbered ranges (1,2,3,4) for particulars of the correction factors KOK in a separate table. Range 1 is the most favourable range from an acoustic point of view. 20160422 We reserve the right to alter specifications. 45 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 04 Airflow, m3/h SFP v 2.5 2.0 1.5 Available total pressure rise, Pa Extract air fan 4 85 80 2 1 3 L w,tot 70dB 75 Supply air fan 4 3 85 1 80 2 L w,tot 70dB 75 Airflow, m3/s The lower limit for the airflow when the unit is operating in the airflow regulation mode. The diagram shows air handling units including standard the end connection panels. The air handling unit complies with requirements to Ecodesign 2016/2018. Recommended working range for sizing. Permissible operating range when the fan is controlled to operate at a lower speed. The lower limit for the airflow when the unit is operating in the airflow regulation mode; see the black broken line in the diagram. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). Min. and Max. Airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The practical flow limits are determined by the external pressure drop. Size 04 Min. airflow (on airflow regulation) m3/s m3/h 288 0.08 Max. airflow m3/h 1620 m3/s 0.45 Correction factors KOK , dB Sound path To outlet duct To inlet duct* To air handling unit surroundings** Octave band, No. / mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 500 1000 2000 4000 8000 1 2 3 4 1 2 3 4 1 2 3 4 -1 -1 -1 -2 -6 -7 -6 -7 -12 -12 -12 -13 -6 -5 -2 -3 -9 -10 -4 -5 -20 -19 -16 -17 -6 -8 -6 -5 -12 -17 -14 -12 -29 -31 -29 -28 -8 -8 -15 -13 -22 -18 -27 -22 -29 -29 -36 -34 4 5 -7 -7 -14 -13 -31 -29 -35 -34 -40 -40 -47 -46 6 -7 -9 -16 -14 -33 -31 -39 -36 -40 -42 -49 -47 7 -12 -13 -22 -20 -38 -37 -44 -42 -46 -47 -56 -54 8 -15 -16 -25 -25 -37 -38 -43 -43 -46 -47 -56 -56 * The integral attenuation of filters and rotary heat exchanger has been taken into account. ** Total sound power level emitted to the surroundings is calculated as the sum of the levels in the supply air and the extract air. 46 We reserve the right to alter specifications. 20160422 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 04 Delivery and Transport within the Site The GOLD RX 04 is produced in one single variant. All of its components are arranged at their given physical location inside the air handling unit. The air handling unit is supplied on a wooden pallet. Base beams/Stand/Foundation The design makes it necessary to mount the GOLD RX 04 on base beams, a stand or some other form of foundation. Otherwise it will not be possible to open the inspection doors. Right-hand version Prefitted base beams are obtainable as optional equipment; a separately supplied stand is available as an accessory. Installation/duct connection options A: Specify right-hand or left-hand version when ordering! If the air handling unit is supplied with all the end connection panels, the version can be changed at the building site by selecting the appropriate version in the hand-held micro terminal. B: The air handling unit can be installed up ended (does not apply to units installed outdoors). Left-hand version Outside air Supply air Extract air Exhaust air Power connection 403 91 91 GOLD GOLD 52 52 J 50 50 Base beams are optional. * The air handling unit is supplied without end connection panel if a duct accessory housed in an insulated casing will be connected. Size A B C D F G H J L Ø Weight, kg 04 750 825 240 345 230 460 920 561 1500 315 214-243 Clear Space for Inspection A clear space of 800 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Power connection 1-phase, 3-wire, 230 V -10/+15%, 50 Hz, 10 A or 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A Rated data per fan Motor shaft power: 0.8 kW (0.41 kW)* motor control system, 1 x 230 V, 50 Hz *The motor control system limits the power of the take-off to the value specified. 20160422 We reserve the right to alter specifications. 47 GOLD Sizing, Installation, Dimensions and Weights GOLD RX Top, rotary heat exchanger, size 04 Left-hand version Right-hand version Airflow, m3/h Airflow, m3/h SFP v SFP v 2.5 2.5 2.0 2.0 1.5 1.5 85 80 4 3 L w,tot 65dB 1 2 75 70 Supply air fan 80 4 3 Extract air fan Available total pressure rise, Pa Available total pressure rise, Pa Extract air fan 80 2 3 1 L w,tot 70dB Supply air fan 85 75 3 2 1 75 4 L w,tot 65dB 4 2 1 70 Airflow, m3/s 80 L w,tot 70dB 75 Airflow, m3/s The lower limit for the airflow when the unit is operating in the airflow regulation mode. The air handling unit complies with requirements to Ecodesign 2016/2018. Recommended working range for sizing. Permissible operating range when the fan is controlled to operate at a lower speed. The lower limit for the airflow when the unit is operating in the airflow regulation mode; see the black broken line in the diagram. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). Min. and Max. Airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The practical flow limits are determined by the external pressure drop. Size Min. airflow Max. airflow (on airflow regulation) m3/s m3/h m3/s m3/h 04 288 0,08 1620 0,45 To outlet duct To inlet duct* To air handling unit surroundings** 48 Sound path To outlet duct To inlet duct* Correction factors, KOK , dB. Fan in lower level. Sound path Correction factors KOK , dB. Fan in upper level. Octave band, No. / mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 500 1000 2000 4000 8000 1 2 3 4 1 2 3 4 1 2 3 4 6 14 4 7 1 5 -1 2 -5 3 -7 -4 -2 -1 -1 -2 -6 -5 -6 -2 -16 -15 -15 -16 -5 -8 -8 -4 -10 -14 -13 -9 -28 -31 -31 -27 -13 -14 -21 -15 -23 -27 -34 -29 -34 -35 -42 -36 4 We reserve the right to alter specifications. 5 -21 -22 -31 -26 -36 -37 -46 -39 -54 -55 -64 -59 6 -26 -26 -35 -31 -42 -46 -53 -49 -59 -59 -68 -64 7 -35 -39 -46 -45 -43 -54 -58 -59 -69 -73 -80 -79 8 -24 -34 -36 -41 -29 -43 -43 -48 -55 -65 -67 -72 To air handling unit surroundings** Octave band, No. / mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 500 1000 2000 4000 8000 1 2 3 4 1 2 3 4 1 2 3 4 4 4 1 3 -1 -1 -5 -5 -7 -7 -10 -8 -1 -1 -1 -1 -5 -7 -6 -6 -15 -15 -15 -15 -6 -9 -10 -7 -11 -13 -16 -11 -29 -32 -33 -30 -15 -14 -23 -17 -24 -21 -34 -25 -36 -35 -44 -38 4 5 -24 -22 -32 -27 -39 -38 -48 -42 -57 -55 -65 -60 6 -29 -27 -37 -32 -45 -44 -55 -50 -62 -60 -70 -65 7 -41 -40 -49 -45 -49 -56 -61 -62 -75 -74 -83 -79 8 -32 -36 -41 -42 -37 -47 -48 -53 -63 -67 -72 -73 * The integral attenuation of filters and rotary heat exchanger has been taken into account. ** Total sound power level emitted to the surroundings is calculated as the sum of the levels in the supply air and the extract air. 20160422 GOLD Sizing, Installation, Dimensions and Weights GOLD RX Top, rotary heat exchanger, size 04 Delivery and Transport within the Site The GOLD RX Top 04 is produced in one single variant. All of its components are arranged at their given physical location inside the air handling unit. The GOLD RX Top 04 is always supplied as one unit. The air handling unit is supplied on a wooden pallet. Base beams/Stand/Foundation Left-hand version The design makes it necessary to mount the GOLD RX Top 04 on base beams, a stand or some other form of foundation. Otherwise it will not be possible to open the inspection doors. Prefitted base beams are obtainable as optional equipment; a separately supplied stand is available as an accessory. Right-hand version Outside air Supply air Extract air Exhaust air Installation/duct connection options A: All the duct connections are arranged from the top of the air handling unit (the unit must not be installed outdoors). B: The air handling unit is supplied in the right-hand version. The unit can be changed to the left-hand version at the building site by selecting the appropriate version in the hand-held micro terminal. 403 91 GOLD GOLD Base beams are optional. 52 52 J 50 50 Power connection Size A B C D F G H J L Ø Weight, kg 04 750 825 233,5 1033 237,5 350 920 561 1500 315 247 Clear Space for Inspection A clear space of 800 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Power connection 1-phase, 3-wire, 230 V -10/+15%, 50 Hz, 10 A or 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A Rated data per fan Motor shaft power: 0.8 kW (0.41 kW)* motor control system, 1 x 230 V, 50 Hz *The motor control system limits the power of the take-off to the value specified. 20160422 We reserve the right to alter specifications. 49 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 05 Airflow, m3/h SFP v 95 90 Available total pressure rise, Pa Ca Ca 4 3 p. 2.5 2.0 1.5 Extract air fan p. va va r. 2 r. 1 2 1 L w,tot 70dB 75 80 95 90 4 Ca 85 Supply air fan Ca p. p. va va r. 2 r. 1 85 2 3 1L w,tot 70dB 75 80 Airflow, m3/s The lower limit for the airflow when the unit is operating in the airflow regulation mode. The limit lines for Ecodesign are calculated with capacity variant 2 and full face end connection panels (accessories). The mean value for supply air and extract air must be within the limit line. Other values in diagrams are calculated for air handling units with standard end connection panels. Recommended working range for sizing. Permissible operating range when the fan is controlled to operate at a lower speed. The lower limit for the airflow when the unit is operating in the airflow regulation mode; see the black broken line in the diagram. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). Limit line, Ecodesign, 2016 Limit line, Ecodesign, 2018 Correction factors KOK , dB Min. and Max. Airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The practical flow limits are determined by the external pressure drop. Size 05 Min. airflow (on airflow regulation) m3/s m3/h 288 0.08 Sound path To outlet duct Max. airflow m3/h 2340 m3/s 0.65 To inlet duct* To unit’s surroundings** Octave band, No. / mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 500 1000 2000 4000 8000 1 2 3 4 1 2 3 4 1 2 3 4 -1 -1 -1 -2 -6 -7 -6 -7 -12 -12 -12 -13 -6 -5 -2 -3 -9 -10 -4 -5 -20 -19 -16 -17 -6 -8 -6 -5 -12 -17 -14 -12 -29 -31 -29 -28 -8 -8 -15 -13 -22 -18 -27 -22 -29 -29 -36 -34 4 5 -7 -7 -14 -13 -31 -29 -35 -34 -40 -40 -47 -46 6 -7 -9 -16 -14 -33 -31 -39 -36 -40 -42 -49 -47 7 -12 -13 -22 -20 -38 -37 -44 -42 -46 -47 -56 -54 8 -15 -16 -25 -25 -37 -38 -43 -43 -46 -47 -56 -56 * The integral attenuation of filters and rotary heat exchanger has been taken into account. ** Total sound power level emitted to the surroundings is calculated as the sum of the levels in the supply air and the extract air. 50 We reserve the right to alter specifications. 20160422 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 05 Delivery and Transport within the Site The GOLD RX 05 is produced in one single variant, in which all the components are arranged at their given physical locations inside the air handling unit. The air handling unit is supplied on a wooden pallet. Base beams/Stand/Foundation The design makes it necessary to mount the GOLD RX 05 on base beams, a stand or some other form of foundation. Otherwise it will not be possible to open the inspection doors. Right-hand version Prefitted base beams are obtainable as optional equipment; a separately supplied stand is available as an accessory. Installation/duct connection options A: Specify right-hand or left-hand version when ordering! If the air handling unit is supplied with all the end connection panels, the version can be changed at the building site by selecting the appropriate version in the hand-held micro terminal. B: The air handling unit can be installed up ended (does not apply to units installed outdoors). Left-hand version Outside air Supply air Extract air Exhaust air Power connection 403 91 91 GOLD GOLD 52 52 J 50 50 Base beams are optional. * The air handling unit is supplied without end connection panel if a duct accessory housed in an insulated casing will be connected. Size A B C D F G H J L Ø Weight, kg 05 750 825 240 345 230 460 920 561 1500 315 214-243 Clear Space for Inspection A clear space of 800 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Power connection 1-phase, 3-wire, 230 V -10/+15%, 50 Hz, 10 A (capacity variant 1) alt. 16 A (capacity variant 2) or 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A Rated data per fan Motor shaft power: 0.8 kW alt. 1.15 kW, motor control system: 1 x 230 V, 50 Hz 20160422 We reserve the right to alter specifications. 51 GOLD Sizing, Installation, Dimensions and Weights GOLD RX Top, rotary heat exchanger, size 05 Left-hand version. Right-hand version. Airflow, m /h 3 Airflow, m3/h SFP v SFP v 2.0 1.5 2.5 2.0 1.5 Available total pressure rise, Pa 90 85 4 3 2 1 L w,tot 65dB 70 80 75 Supply air fan 85 85 4 3 2 1 L w,tot 70dB 90 85 4 3 L w,tot 65dB 75 Supply air fan 2 1 80 80 4 3 Extract air fan Available total pressure rise, Pa Extract air fan 2.5 70 75 2 1 Airflow, m3/s L w,tot 70dB 75 80 Airflow, m3/s The lower limit for the airflow when the unit is operating in the airflow regulation mode. For Ecodesign, the mean value for supply air and extract air must be within the limit line. Recommended working range for sizing. Permissible operating range when the fan is controlled to operate at a lower speed. The lower limit for the airflow when the unit is operating in the airflow regulation mode; see the black broken line in the diagram. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). Limit line, Ecodesign, 2016 Limit line, Ecodesign, 2018 Min. and Max. Airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The practical flow limits are determined by the external pressure drop. Size Min. airflow Max. airflow (on airflow regulation) m3/s m3/h m3/s m3/h 05 288 0,08 2340 0,65 Correction factors, KOK , dB. Fan in lower level Sound path To outlet duct To inlet duct* To air handling unit surroundings** 52 Correction factors, KOK , dB. Fan in upper level. Sound path To outlet duct To inlet duct* Octave band, No. / mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 500 1000 2000 4000 8000 1 2 3 4 1 2 3 4 1 2 3 4 6 14 4 7 1 5 -1 2 -5 3 -7 -4 -2 -1 -1 -2 -6 -5 -6 -2 -16 -15 -15 -16 -5 -8 -8 -4 -10 -14 -13 -9 -28 -31 -31 -27 -13 -14 -21 -15 -23 -27 -34 -29 -34 -35 -42 -36 4 We reserve the right to alter specifications. 5 -21 -22 -31 -26 -36 -37 -46 -39 -54 -55 -64 -59 6 -26 -26 -35 -31 -42 -46 -53 -49 -59 -59 -68 -64 7 -35 -39 -46 -45 -43 -54 -58 -59 -69 -73 -80 -79 8 -24 -34 -36 -41 -29 -43 -43 -48 -55 -65 -67 -72 To air handling unit surroundings** Octave band, No. / mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 500 1000 2000 4000 8000 1 2 3 4 1 2 3 4 1 2 3 4 4 4 1 3 -1 -1 -5 -5 -7 -7 -10 -8 -1 -1 -1 -1 -5 -7 -6 -6 -15 -15 -15 -15 -6 -9 -10 -7 -11 -13 -16 -11 -29 -32 -33 -30 -15 -14 -23 -17 -24 -21 -34 -25 -36 -35 -44 -38 4 5 -24 -22 -32 -27 -39 -38 -48 -42 -57 -55 -65 -60 6 -29 -27 -37 -32 -45 -44 -55 -50 -62 -60 -70 -65 7 -41 -40 -49 -45 -49 -56 -61 -62 -75 -74 -83 -79 8 -32 -36 -41 -42 -37 -47 -48 -53 -63 -67 -72 -73 * The integral attenuation of filters and rotary heat exchanger has been taken into account. ** Total sound power level emitted to the surroundings is calculated as the sum of the levels in the supply air and the extract air. 20160422 GOLD Sizing, Installation, Dimensions and Weights GOLD RX Top, rotary heat exchanger, size 05 Delivery and Transport within the Site The COMPACT Top 05 unit is produced in one variant in which all the components are arranged at their given physical location inside the unit. The GOLD RX Top 05 is always supplied as one unit. The air handling unit is supplied on a wooden pallet. Base beams/Stand/Foundation Left-hand version The design makes it necessary to mount the GOLD RX Top 05 on base beams, a stand or some other form of foundation. Otherwise it will not be possible to open the inspection doors. Prefitted base beams are obtainable as optional equipment; a separately supplied stand is available as an accessory. Right-hand version Outside air Supply air Extract air Exhaust air Installation/duct connection options A: All the duct connections are arranged from the top of the air handling unit (the unit must not be installed outdoors). B: The air handling unit is supplied in the right-hand version. The unit can be changed to the left-hand version at the building site by selecting the appropriate version in the hand-held micro terminal. 403 91 GOLD GOLD Base beams are optional. 52 52 J 50 50 Power connection Size A B C D F G H J L Ø Weight, kg 05 750 825 233,5 1033 237,5 350 920 561 1500 315 247 Clear Space for Inspection A clear space of 800 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Power connection 1-phase, 3-wire, 230 V -10/+15%, 50 Hz, 10 A or 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A Rated data per fan Motor shaft power 0.8 kW motor control system, 1 x 230 V, 50 Hz 20160422 We reserve the right to alter specifications. 53 GOLD Sizing, installation, dimensions and weights GOLD RX, rotary heat exchanger, size 07 Airflow, m3/h SFP v 2.5 2.0 1.5 Available total pressure rise, Pa 95 90 Ca 4 Ca p. Extract air fan p. va va r. 2 r. 1 2 3 1 L w,tot 70dB 95 75 80 90 85 Supply air fan Ca 4 Ca p. va p. va r. 2 r. 1 2 3 1 L w,tot 70dB 75 80 85 Airflow, m3/s The lower limit for the airflow when the unit is operating in the airflow regulation mode. The diagram shows air handling units including standard the end connection panels. The air handling unit complies with requirements to Ecodesign 2016/2018. Recommended working range for sizing. Permissible operating range when the fan is controlled to operate at a lower speed. The lower limit for the airflow when the unit is operating in the airflow regulation mode; see the black broken line in the diagram. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The practical flow limits are determined by the external pressure drop. Size 07 Min. airflow (for airflow regulation) m3/s m3/h 288 0,08 Max. airflow m3/h 2700 m3/s 0,75 Correction factors, KOK , dB Sound path To outlet duct To inlet duct* To air handling unit surroundings** Octave band, no./mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 500 1000 2000 4000 8000 1 2 3 4 1 2 3 4 1 2 3 4 -1 -1 -1 -2 -6 -7 -6 -7 -12 -12 -12 -13 -6 -5 -2 -3 -9 -10 -4 -5 -20 -19 -16 -17 -6 -8 -6 -5 -12 -17 -14 -12 -29 -31 -29 -28 -8 -8 -15 -13 -22 -18 -27 -22 -29 -29 -36 -34 4 5 -7 -7 -14 -13 -31 -29 -35 -34 -40 -40 -47 -46 6 -7 -9 -16 -14 -33 -31 -39 -36 -40 -42 -49 -47 7 -12 -13 -22 -20 -38 -37 -44 -42 -46 -47 -56 -54 8 -15 -16 -25 -25 -37 -38 -43 -43 -46 -47 -56 -56 * The integral attenuation of filters and rotary heat exchanger has been taken into account. ** Total sound power level emitted to the surroundings is calculated as the sum of the levels in the supply air and the extract air. 54 We reserve the right to alter specifications. 20160422 GOLD Sizing, installation, dimensions and weights GOLD RX, rotary heat exchanger, size 07 Delivery and transport within the site The GOLD RX 07 is produced in one single variant. All of its components are arranged at their given physical location inside the air handling unit. The air handling unit is supplied on a wooden pallet. Base beams/Stand/Foundation The design makes it necessary to mount the GOLD RX 07 on base beams, a stand or some other form of foundation. Otherwise it will not be possible to open the inspection doors. Right-hand version Prefitted base beams are obtainable as optional equipment; a separately supplied stand is available as an accessory. Installation/duct connection options A: Specify right-hand or left-hand version when ordering. If the air handling unit is supplied with all the end connection panels, the version can be changed at the building site by selecting the appropriate version in the hand-held micro terminal. B: The air handling unit can be installed up ended (does not apply to units installed outdoors). Left-hand version Outdoor air Supply air Extract air Exhaust air Power connection 403 91 91 GOLD GOLD 52 52 J 50 50 Base beams are optional. * The air handling unit is supplied without end connection panel if a duct accessory housed in an insulated casing will be connected. Size A B C D F G H J L Ø Weight, kg 07 800 995 277,5 440 271 543 1085 730 1600 400 262-301 Clear space for inspection A clear space of 800 mm should be provided in front of the unit and at least 200 mm should be provided above the junction hood. Power connection 1-phase, 3-wire cable, 230 V -10/+15%, 50 Hz, 10 A (capacity variant 1) alt. 16 A (capacity variant 2) or 3-phase, 5-wire cable, 400 V -10/+15%, 50 Hz, 10 A Rated data per fan Motor shaft power: 0.8 kW alt. 1.15 kW, motor control system: 1 x 230 V, 50 Hz 20160422 We reserve the right to alter specifications. 55 GOLD Sizing, installation, dimensions and weights GOLD RX Top, rotary heat exchanger, size 07 Left-hand version Right-hand version Airflow, m3/h Airflow, m3/h SFP v SFP v 2.5 2.5 2.0 2.0 1.5 Extract air fan 85 4 2 3 1 L w,tot 65dB 70 75 80 85 Supply air fan 85 80 4 3 1 85 Available total pressure rise, Pa Available total pressure rise, Pa 90 1.5 4 2 3 1 L w,tot 70dB 75 80 Supply air fan 90 85 4 2 2 3 L w,tot 65dB Extract air fan 80 70 75 1 80 L w,tot 70dB Airflow, m3/s 75 80 85 Airflow, m3/s The lower limit for the airflow when the unit is operating in the airflow regulation mode. The air handling unit complies with requirements to Ecodesign 2016/2018. Recommended working range for sizing. Permissible operating range when the fan is controlled to operate at a lower speed. The lower limit for the airflow when the unit is operating in the airflow regulation mode; see the black broken line in the diagram. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). Min. and Max. Airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The practical flow limits are determined by the external pressure drop. Size 07 Min. airflow (for airflow regulation) m3/s m3/h 288 0,08 Max. airflow m3/h 2700 To inlet duct* To outlet duct To inlet duct* To air handling unit surroundings** 56 Octave band, no./mid-frequency, Hz Region in diagram 1 2 3 63 125 250 500 1000 2000 4000 8000 1 2 3 4 1 2 3 4 1 2 3 4 6 14 4 7 1 5 -1 2 -5 3 -7 -4 -2 -1 -1 -2 -6 -5 -6 -2 -16 -15 -15 -16 -5 -8 -8 -4 -10 -14 -13 -9 -28 -31 -31 -27 -13 -14 -21 -15 -23 -27 -34 -29 -34 -35 -42 -36 4 We reserve the right to alter specifications. 5 -21 -22 -31 -26 -36 -37 -46 -39 -54 -55 -64 -59 6 -26 -26 -35 -31 -42 -46 -53 -49 -59 -59 -68 -64 7 -35 -39 -46 -45 -43 -54 -58 -59 -69 -73 -80 -79 Sound path To outlet duct m3/s 0,75 Correction factors, KOK , dB. Fan in lower level Sound path Correction factors, KOK , dB. Fan in upper level. 8 -24 -34 -36 -41 -29 -43 -43 -48 -55 -65 -67 -72 To air handling unit surroundings** Octave band, no./mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 500 1000 2000 4000 8000 1 2 3 4 1 2 3 4 1 2 3 4 4 4 1 3 -1 -1 -5 -5 -7 -7 -10 -8 -1 -1 -1 -1 -5 -7 -6 -6 -15 -15 -15 -15 -6 -9 -10 -7 -11 -13 -16 -11 -29 -32 -33 -30 -15 -14 -23 -17 -24 -21 -34 -25 -36 -35 -44 -38 4 5 -24 -22 -32 -27 -39 -38 -48 -42 -57 -55 -65 -60 6 -29 -27 -37 -32 -45 -44 -55 -50 -62 -60 -70 -65 7 -41 -40 -49 -45 -49 -56 -61 -62 -75 -74 -83 -79 8 -32 -36 -41 -42 -37 -47 -48 -53 -63 -67 -72 -73 * The integral attenuation of filters and rotary heat exchanger has been taken into account. ** T otal sound power level emitted to the surroundings is calculated as the sum of the levels in the supply air and the extract air. 20160422 GOLD Sizing, installation, dimensions and weights GOLD RX Top, rotary heat exchanger, size 07 Delivery and transport within the site The GOLD RX Top 07 unit is produced in one variant in which all the components are arranged at their given physical location inside the unit. The GOLD RX Top 08 is always supplied as one unit. The air handling unit is supplied on a wooden pallet. Base beams/Stand/Foundation The design makes it necessary to mount the GOLD RX Top 07 on base beams, a stand or some other form of foundation. Otherwise it will not be possible to open the inspection doors. Left-hand version Prefitted base beams are obtainable as optional equipment; a separately supplied stand is available as an accessory. Right-hand version Outdoor air Supply air Extract air Exhaust air Installation/duct connection options A: All the duct connections are arranged from the top of the air handling unit (the unit must not be installed outdoors). B: The air handling unit is supplied in the right-hand version. The unit can be changed to the left-hand version at the building site by selecting the appropriate version in the hand-held micro terminal. 403 91 GOLD GOLD 52 52 J 50 50 Base beams are optional. Power connection Size A B C D F G H J L Ø Weight, kg 07 800 995 276 1048 280 435 1085 730 1600 400 306 Clear space for inspection A clear space of 900 mm should be provided in front of the unit and at least 200 mm should be provided above the junction hood. Power connection 1-phase, 3-wire cable, 230 V -10/+15%, 50 Hz, 10 A or 3-phase, 5-wire cable, 400 V -10/+15%, 50 Hz, 10 A Rated data per fan Motor shaft power: 0.8 kW, motor control system: 1 x 230 V, 50 Hz 20160422 We reserve the right to alter specifications. 57 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 08 Airflow, m3/h SFP v 2.5 2.0 1.5 90 Extract air fan Available total pressure rise, Pa Ca Ca 4 3 p. p. va va r. 2 r. 1 2 1 L w,tot 75dB 80 85 Supply air fan 90 Ca Ca p. va 4 3 1 p. va r. 2 r. 1 2 L w,tot 75dB 80 85 Airflow, m3/s The lower limit for the airflow when the unit is operating in the airflow regulation mode. The limit line for Ecodesign 2018 is calculated with capacity variant 2 and full face end connection panels (accessories). The mean value for supply air and extract air must be within the limit line. The air handling unit complies with requirements to Ecodesign 2016. Other values in diagrams are calculated for air handling units with standard end connection panels. Recommended working range for sizing. Permissible operating range when the fan is controlled to operate at a lower speed. The lower limit for the airflow when the unit is operating in the airflow regulation mode; see the black broken line in the diagram. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). Limit line, Ecodesign, 2018 Correction factors KOK , dB Min. and Max. Airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The practical flow limits are determined by the external pressure drop. Size 08 Min. airflow (on airflow regulation) m3/s m3/h 720 0.20 Sound path To outlet duct Max. airflow m3/h 3600 m3/s 1.00 To inlet duct* To air handling unit surroundings** Octave band, No. / mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 500 1000 2000 4000 8000 1 2 3 4 1 2 3 4 1 2 3 4 -1 -1 -1 -2 -6 -7 -6 -7 -12 -12 -12 -13 -6 -5 -2 -3 -9 -10 -4 -5 -20 -19 -16 -17 -6 -8 -6 -5 -12 -17 -14 -12 -29 -31 -29 -28 -8 -8 -15 -13 -22 -18 -27 -22 -29 -29 -36 -34 4 5 -7 -7 -14 -13 -31 -29 -35 -34 -40 -40 -47 -46 6 -7 -9 -16 -14 -33 -31 -39 -36 -40 -42 -49 -47 7 -12 -13 -22 -20 -38 -37 -44 -42 -46 -47 -56 -54 8 -15 -16 -25 -25 -37 -38 -43 -43 -46 -47 -56 -56 * The integral attenuation of filters and rotary heat exchanger has been taken into account. ** Total sound power level emitted to the surroundings is calculated as the sum of the levels in the supply air and the extract air. 58 We reserve the right to alter specifications. 20160422 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 08 Delivery and Transport within the Site The GOLD RX 08 is produced in one single variant, in which all the components are arranged at their given physical locations inside the air handling unit. The air handling unit is supplied on a wooden pallet. Base beams/Stand/Foundation The design makes it necessary to mount the GOLD RX 08 on base beams, a stand or some other form of foundation. Otherwise it will not be possible to open the inspection doors. Right-hand version Prefitted base beams are obtainable as optional equipment; a separately supplied stand is available as an accessory. Installation/duct connection options A: Specify right-hand or left-hand version when ordering! If the air handling unit is supplied with all the end connection panels, the version can be changed at the building site by selecting the appropriate version in the hand-held micro terminal. B: The air handling unit can be installed up ended (does not apply to units installed outdoors). Left-hand version Outside air Supply air Extract air Exhaust air Power connection 403 91 91 GOLD GOLD 52 52 J 50 50 Base beams are optional. * The air handling unit is supplied without end connection panel if a duct accessory housed in an insulated casing will be connected. Size A B C D F G H J L Ø Weight, kg 08 800 995 277,5 440 271 543 1085 730 1600 400 270-309 Clear Space for Inspection A clear space of 800 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Power connection Capacity variant 1: 1-phase, 3-wire, 230 V -10/+15%, 50 Hz, 16 A or 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A Capacity variant 2: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A Rated data per fan Capacity variant 1: Motor shaft power: 1.15 kW, motor control system: 1 x 230 V, 50 Hz Capacity variant 2: Motor shaft power: 1.6 kW, motor control system: 3 x 400 V, 50 Hz 20160422 We reserve the right to alter specifications. 59 GOLD Sizing, Installation, Dimensions and Weights GOLD RX Top, rotary heat exchanger, size 08 Left-hand version. Right-hand version. Airflow, m3/h Airflow, m3/h SFP v SFP v 2.5 2.0 1.5 Available total pressure rise, Pa 90 4 2 1 L w,tot 70dB 75 80 85 Supply air fan 85 85 4 3 2 1 L w,tot 75dB 80 Supply air fan 90 4 4 3 2.5 Extract air fan Available total pressure rise, Pa Extract air fan 3 2.0 1.5 1 L w,tot 70dB 2 75 2 3 1 80 Airflow, m3/s L w,tot 75dB 80 85 Airflow, m3/s The lower limit for the airflow when the unit is operating in the airflow regulation mode. For Ecodesign, the mean value for supply air and extract air must be within the limit line. Recommended working range for sizing. Permissible operating range when the fan is controlled to operate at a lower speed. The lower limit for the airflow when the unit is operating in the airflow regulation mode; see the black broken line in the diagram. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). Limit line, Ecodesign, 2016 Limit line, Ecodesign, 2018 Correction factors KOK , dB Min. and Max. Airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The practical flow limits are determined by the external pressure drop. Sound path To outlet duct Size 08 Min. airflow (on airflow regulation) m3/s m3/h 720 0.20 Max. airflow m3/h 3600 m3/s 1.00 To inlet duct* To unit’s surroundings** Octave band, No. / mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 500 1000 2000 4000 8000 1 2 3 4 1 2 3 4 1 2 3 4 -1 -1 -1 -2 -6 -7 -6 -7 -12 -12 -12 -13 -6 -5 -2 -3 -9 -10 -4 -5 -20 -19 -16 -17 -6 -8 -6 -5 -10 -15 -12 -10 -29 -31 -29 -28 -8 -8 -15 -13 -19 -15 -24 -19 -29 -29 -36 -34 4 5 -7 -7 -14 -13 -25 -23 -29 -28 -40 -40 -47 -46 6 -7 -9 -16 -14 -23 -21 -29 -26 -40 -42 -49 -47 7 -12 -13 -22 -20 -25 -24 -31 -29 -46 -47 -56 -54 8 -15 -16 -25 -25 -22 -23 -28 -28 -46 -47 -56 -56 * The integral attenuation of filters and rotary heat exchanger has been taken into account. ** Total sound power level emitted to the surroundings is calculated as the sum of the levels in the supply air and the extract air. 60 We reserve the right to alter specifications. 20160422 GOLD Sizing, Installation, Dimensions and Weights GOLD RX Top, rotary heat exchanger, size 08 Delivery and Transport within the Site The GOLD RX Top unit is produced in one variant in which all the components are arranged at their given physical location inside the unit. The GOLD RX Top 08 is always supplied as one unit. The air handling unit is supplied on a wooden pallet. Base beams/Stand/Foundation Left-hand version The design makes it necessary to mount the GOLD RX Top 08 on base beams, a stand or some other form of foundation. Otherwise it will not be possible to open the inspection doors. Prefitted base beams are obtainable as optional equipment; a separately supplied stand is available as an accessory. Right-hand version Outside air Supply air Extract air Exhaust air Installation/duct connection options A: All the duct connections are arranged from the top of the air handling unit (the unit must not be installed outdoors). B: The air handling unit is supplied in the right-hand version. The unit can be changed to the left-hand version at the building site by selecting the appropriate version in the hand-held micro terminal. 403 91 GOLD GOLD Base beams are optional. 52 52 J 50 50 Power connection Size A B C D F G H J L Ø Weight, kg 08 800 995 276 1048 280 435 1085 730 1600 400 310 Clear Space for Inspection A clear space of 900 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Power connection 1-phase, 3-wire, 230 V -10/+15%, 50 Hz, 16 A or 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A Rated data per fan Motor shaft power 1.15 kW motor control system, 1 x 230 V, 50 Hz 20160422 We reserve the right to alter specifications. 61 GOLD Sizing, installation, dimensions and weights GOLD RX, rotary heat exchanger, size 11 Airflow, m3/h SFP v 2.5 2.0 1.5 90 Extract air fan Available total pressure rise, Pa Ca Ca 4 3 p. p. va va r. 2 r. 1 2 1 L w,tot 75dB 80 85 90 Supply air fan Ca Ca 4 3 p. va p. va r. 2 r. 1 2 1 L w,tot 75dB 80 85 Airflow, m3/s The lower limit for the airflow when the unit is operating in the airflow regulation mode. The diagram shows air handling units including standard the end connection panels. The air handling unit complies with requirements to Ecodesign 2016/2018. Recommended working range for sizing. Permissible operating range when the fan is controlled to operate at a lower speed. The lower limit for the airflow when the unit is operating in the airflow regulation mode; see the black broken line in the diagram. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The practical flow limits are determined by the external pressure drop. Size 11 Min. airflow (for airflow regulation) m3/s m3/h 720 0,20 Max. airflow m3/h 3960 m3/s 1,10 Correction factors, KOK , dB Sound path To outlet duct To inlet duct* To air handling unit surroundings** Octave band, no./mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 500 1000 2000 4000 8000 1 2 3 4 1 2 3 4 1 2 3 4 -1 -1 -1 -2 -6 -7 -6 -7 -12 -12 -12 -13 -6 -5 -2 -3 -9 -10 -4 -5 -20 -19 -16 -17 -6 -8 -6 -5 -12 -17 -14 -12 -29 -31 -29 -28 -8 -8 -15 -13 -22 -18 -27 -22 -29 -29 -36 -34 4 5 -7 -7 -14 -13 -31 -29 -35 -34 -40 -40 -47 -46 6 -7 -9 -16 -14 -33 -31 -39 -36 -40 -42 -49 -47 7 -12 -13 -22 -20 -38 -37 -44 -42 -46 -47 -56 -54 8 -15 -16 -25 -25 -37 -38 -43 -43 -46 -47 -56 -56 * The integral attenuation of filters and rotary heat exchanger has been taken into account. ** Total sound power level emitted to the surroundings is calculated as the sum of the levels in the supply air and the extract air. 62 We reserve the right to alter specifications. 20160422 GOLD Sizing, installation, dimensions and weights GOLD RX, rotary heat exchanger, size 11 Delivery and transport within the site The GOLD RX 11 is always supplied as one unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. The three sections are joined together by bolts and the electrical and control cables between the sections have quick-fit connectors. Fan arrangement 2 Fan arrangement 1 Right-hand version The air handling unit is delivered on wooden beams. Duct connection options A: Specify right-hand or left-hand version when ordering. If the air handling unit is supplied with all the end connection panels, the version can be changed at the building site by selecting the appropriate version in the hand-held micro terminal. B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when placing orders. Fan arrangement 1 Fan arrangement 2 Left-hand version Outdoor air Supply air Extract air Exhaust air Power connection K 403 16 K 91 91 GOLD J 50 50 GOLD 52 52 J 50 50 The dimension print shows the connection configuration for fan arrangement 1. For fan arrangement 2 the connections are mirror-inverted. * The air handling unit is supplied without end connection panel if a duct accessory housed in an insulated casing will be connected. Size A B C D F G H J K L Ø Weight, kg 11 655 1199 324 550 324 647 1295 935 551 1860 500 444-496 Division into sections for transport A D+19 mm A Power connection The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight: A = 141-167 kg, D = 162 kg. Clear space for inspection A clear space of 800 mm should be provided in front of the unit and at least 200 mm should be provided above the junction hood. Capacity variant 1: 1-phase, 3-wire cable, 230 V -10/+15%, 50 Hz, 16 A or 3-phase, 5-wire cable, 400 V -10/+15%, 50 Hz, 10 A Capacity variant 2: 3-phase, 5-wire cable, 400 V -10/+15%, 50 Hz, 10 A Rated data per fan Capacity variant 1: Motor shaft power: 1.15 kW, motor control system: 1 x 230 V, 50 Hz Capacity variant 2: Motor shaft power: 1.6 kW, motor control system: 3 x 400 V, 50 Hz 20160422 We reserve the right to alter specifications. 63 GOLD Sizing, installation, dimensions and weights GOLD RX Top, rotary heat exchanger, size 11 Left-hand version Right-hand version Airflow, m3/h Airflow, m3/h SFP v SFP v 2.5 2.5 2.0 1.5 Available total pressure rise, Pa 2 3 1 L w,tot 70dB 75 80 85 90 Supply air fan 85 4 3 Extract air fan Available total pressure rise, Pa Extract air fan 90 4 85 4 3 2 1 L w,tot 75dB 80 85 Supply air fan 90 4 2 1 L w,tot 70dB 2.0 1.5 3 75 80 85 2 1L Airflow, m3/s w,tot 75dB 80 85 90 Airflow, m3/s The lower limit for the airflow when the unit is operating in the airflow regulation mode. For Ecodesign 2018, the mean value for supply air and extract air must be within the limit line. Recommended working range for sizing. Permissible operating range when the fan is controlled to operate at a lower speed. The lower limit for the airflow when the unit is operating in the airflow regulation mode; see the black broken line in the diagram. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). Limit line, Ecodesign, 2018 Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The practical flow limits are determined by the external pressure drop. Size 11 Min. airflow (for airflow regulation) m3/s m3/h 720 0,20 Max. airflow m3/h 3960 m3/s 1,10 Correction factors, KOK , dB Sound path To outlet duct To inlet duct* To air handling unit surroundings** Octave band, no./mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 500 1000 2000 4000 8000 1 2 3 4 1 2 3 4 1 2 3 4 -1 -1 -1 -2 -6 -7 -6 -7 -12 -12 -12 -13 -6 -5 -2 -3 -9 -10 -4 -5 -20 -19 -16 -17 -6 -8 -6 -5 -10 -15 -12 -10 -29 -31 -29 -28 -8 -8 -15 -13 -19 -15 -24 -19 -29 -29 -36 -34 4 5 -7 -7 -14 -13 -25 -23 -29 -28 -40 -40 -47 -46 6 -7 -9 -16 -14 -23 -21 -29 -26 -40 -42 -49 -47 7 -12 -13 -22 -20 -25 -24 -31 -29 -46 -47 -56 -54 8 -15 -16 -25 -25 -22 -23 -28 -28 -46 -47 -56 -56 * The integral attenuation of filters and rotary heat exchanger has been taken into account. ** Total sound power level emitted to the surroundings is calculated as the sum of the levels in the supply air and the extract air. 64 We reserve the right to alter specifications. 20160422 GOLD Sizing, installation, dimensions and weights GOLD RX Top, rotary heat exchanger, size 11 Delivery and transport within the site The GOLD RX Top 11 unit is produced in one variant in which all the components are arranged at their given physical location inside the unit. The GOLD RX Top 11 is always supplied as one unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. The three sections are joined together by bolts and the electrical and control cables between the sections have quick-fit connectors. Left-hand version Right-hand version The air handling unit is delivered on wooden beams. Duct connection options Outdoor air Supply air A: All the duct connections are arranged from the top of the air handling unit (the unit must not be installed outdoors). Extract air Exhaust air B: The air handling unit is supplied in the right-hand version. The unit can be changed to the left-hand version at the building site by selecting the appropriate version in the hand-held micro terminal. 403 16 16 GOLD 91 GOLD 52 52 J 50 50 Power connection C K C Size A B C D F G H J K L Ø Weight, kg 11 655 1199 332 550 333 533 1295 935 1196 1860 500 488 Division into sections for transport A D+19 mm A Clear space for inspection The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight: A = 163 kg, D = 162 kg. A clear space of 800 mm should be provided in front of the unit and at least 200 mm should be provided above the junction hood. Power connection 1-phase, 3-wire cable, 230 V -10/+15%, 50 Hz, 16 A or 3-phase, 5-wire cable, 400 V -10/+15%, 50 Hz, 10 A Rated data per fan Motor shaft power: 1.15 kW, motor control system: 1 x 230 V, 50 Hz 20160422 We reserve the right to alter specifications. 65 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 12 Airflow, m3/h SFP v 2.5 2.0 1.5 Extract air fan 90 Available total pressure rise, Pa Ca Ca p. p. va va r. 2 r. 1 3 2 1 L w,tot 75dB 80 85 90 Supply air fan Ca Ca 3 p. p. va va r. 2 r. 1 2 1 L w,tot 75dB 80 85 Airflow, m3/s The lower limit for the airflow when the unit is operating in the airflow regulation mode. The limit line for Ecodesign 2018 is calculated with capacity variant 2 and full face end connection panels (accessories). The mean value for supply air and extract air must be within the limit line. The air handling unit complies with requirements to Ecodesign 2016. Other values in diagrams are calculated for air handling units with standard end connection panels. Recommended working range for sizing. Permissible operating range when the fan is controlled to operate at a lower speed. The lower limit for the airflow when the unit is operating in the airflow regulation mode; see the black broken line in the diagram. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). Limit line, Ecodesign, 2018 Min. and Max. Airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The practical flow limits are determined by the external pressure drop. Size 12 Min. airflow (on airflow regulation) m3/s m3/h 720 0.20 Max. airflow m3/h 5040 m3/s 1.40 Correction factors KOK , dB Sound path To outlet duct To inlet duct* To air handling unit surroundings** Octave band, No. / mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 500 1000 2000 4000 8000 1 2 3 1 2 3 1 2 3 -1 -1 -1 -6 -7 -6 -12 -12 -12 -6 -5 -2 -9 -10 -4 -20 -19 -16 -6 -8 -6 -12 -17 -14 -29 -31 -29 -8 -8 -15 -22 -18 -27 -29 -29 -36 4 5 -7 -7 -14 -31 -29 -35 -40 -40 -47 6 -7 -9 -16 -33 -31 -39 -40 -42 -49 7 -12 -13 -22 -38 -37 -44 -46 -47 -56 8 -15 -16 -25 -37 -38 -43 -46 -47 -56 * The integral attenuation of filters and rotary heat exchanger has been taken into account. ** Total sound power level emitted to the surroundings is calculated as the sum of the levels in the supply air and the extract air. 66 We reserve the right to alter specifications. 20160422 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 12 Delivery and Transport within the Site The GOLD RX 12 is always supplied as one unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. The three sections are joined together by bolts and the electrical and control cables have quick connectors. Fan arrangement 2 Fan arrangement 1 The air handling unit is delivered on wooden beams. Right-hand version Duct connection options A: Specify right-hand or left-hand version when ordering! If the air handling unit is supplied with all the end connection panels, the version can be changed at the building site by selecting the appropriate version in the hand-held micro terminal. B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when placing orders! Fan arrangement 1 Fan arrangement 2 Left-hand version Outside air Supply air Extract air Exhaust air Power connection K 403 16 K 91 91 GOLD J 50 50 GOLD 52 52 J 50 50 The dimension print shows the connection configuration for fan arrangement 1. For fan arrangement 2 the connections are mirror-inverted. * The air handling unit is supplied without end connection panel if a duct accessory housed in an insulated casing will be connected. Size A B C D F G H J K L Ø Weight, kg 12 655 1199 324 550 324 647 1295 935 551 1860 500 466-518 Division into sections for transport A D+19 mm A Clear space for inspection The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight: A = 152-178 kg, D = 162 kg. A clear space of 800 mm should be provided in front of the unit and at least 200 mm should be provided above the junction hood. Power connection 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A Rated data per fan Motor shaft power: 1.6 kW alt. 2.4 kW, motor control system: 3 x 400 V, 50 Hz 20160422 We reserve the right to alter specifications. 67 GOLD Sizing, Installation, Dimensions and Weights GOLD RX Top, rotary heat exchanger, size 12 Left-hand version. Right-hand version. Airflow, m /h 3 Airflow, m3/h SFP v SFP v 2.5 2.5 2.0 1.5 90 2 1 L w,tot 75dB 80 85 Supply air fan Extract air fan Available total pressure rise, Pa Available total pressure rise, Pa Extract air fan 3 85 3 2 1 L w,tot 75dB 80 Supply air fan 85 90 2 3 2 3 1 L w,tot 70dB 75 2.0 1.5 80 1 L w,tot 75dB Airflow, m3/s 80 85 Airflow, m3/s The lower limit for the airflow when the unit is operating in the airflow regulation mode. For Ecodesign, the mean value for supply air and extract air must be within the limit line. Recommended working range for sizing. Permissible operating range when the fan is controlled to operate at a lower speed. The lower limit for the airflow when the unit is operating in the airflow regulation mode; see the black broken line in the diagram. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). Limit line, Ecodesign, 2016 Limit line, Ecodesign, 2018 Min. and Max. Airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The practical flow limits are determined by the external pressure drop. Size 12 Min. airflow (on airflow regulation) m3/s m3/h 720 0,20 Max. airflow m3/h 5040 m3/s 1,40 Correction factors KOK , dB Sound path To outlet duct To inlet duct* To air handling unit surroundings** Octave band, No. / mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 500 1000 2000 4000 8000 1 2 3 1 2 3 1 2 3 -1 -1 -1 -6 -7 -6 -12 -12 -12 -6 -5 -2 -9 -10 -4 -20 -19 -16 -6 -8 -6 -10 -15 -12 -29 -31 -29 -8 -8 -15 -19 -15 -24 -29 -29 -36 4 5 -7 -7 -14 -25 -23 -29 -40 -40 -47 6 -7 -9 -16 -23 -21 -29 -40 -42 -49 7 -12 -13 -22 -25 -24 -31 -46 -47 -56 8 -15 -16 -25 -22 -23 -28 -46 -47 -56 * The integral attenuation of filters and rotary heat exchanger has been taken into account. ** Total sound power level emitted to the surroundings is calculated as the sum of the levels in the supply air and the extract air. 68 We reserve the right to alter specifications. 20160422 GOLD Sizing, Installation, Dimensions and Weights GOLD RX Top, rotary heat exchanger, size 12 Delivery and Transport within the Site The GOLD RX Top unit is produced in one variant in which all the components are arranged at their given physical location inside the unit. The GOLD RX Top 12 is always supplied as one unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. The three sections are joined together by bolts and the electrical and control cables have quick connectors. Left-hand version Right-hand version The air handling unit is delivered on wooden beams. Duct connection options A: All the duct connections are arranged from the top of the air handling unit (the unit must not be installed outdoors). Outside air Supply air Extract air Exhaust air B: The air handling unit is supplied in the right-hand version. The unit can be changed to the left-hand version at the building site by selecting the appropriate version in the hand-held micro terminal. 403 16 16 GOLD 91 GOLD 52 52 J 50 50 Power connection C K C Size A B C D F G H J K L Ø Weight, kg 12 655 1199 332 550 333 533 1295 935 1196 1860 500 504 Division into sections for transport A D+19 mm A Clear Space for Inspection The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight: A = 171 kg, D = 162 kg. A clear space of 800 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Power connection 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A Rated data per fan Motor shaft power: 1.6 kW, motor control system, 3 x 400 V, 50 Hz 20160422 We reserve the right to alter specifications. 69 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 14 Airflow, m3/h SFP v 2.5 2.0 1.5 Extract air fan Available total pressure rise, Pa Ca Ca 3 p. p. va va r. 2 r. 1 2 1 L w,tot 75dB 80 85 90 90 Supply air fan Ca Ca 3 p. va p. va r. 2 r. 1 2 1 L w,tot 75dB 80 85 Airflow, m3/s The lower limit for the airflow when the unit is operating in the airflow regulation mode. The diagram shows air handling units including standard the end connection panels. The air handling unit complies with requirements to Ecodesign 2016/2018. Recommended working range for sizing. Permissible operating range when the fan is controlled to operate at a lower speed. The lower limit for the airflow when the unit is operating in the airflow regulation mode; see the black broken line in the diagram. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). Min. and Max. Airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The practical flow limits are determined by the external pressure drop. Size 14 Min. airflow (on airflow regulation) m3/s m3/h 720 0,20 Max. airflow m3/h 5940 m3/s 1,65 Correction factors KOK , dB Sound path To outlet duct To inlet duct* To air handling unit surroundings** Octave band, No. / mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 500 1000 2000 4000 8000 1 2 3 1 2 3 1 2 3 -1 -1 -1 -6 -7 -6 -12 -12 -12 -6 -5 -2 -9 -10 -4 -20 -19 -16 -6 -8 -6 -10 -15 -12 -29 -31 -29 -8 -8 -15 -19 -15 -24 -29 -29 -36 4 5 -7 -7 -14 -25 -23 -29 -40 -40 -47 6 -7 -9 -16 -23 -21 -29 -40 -42 -49 7 -12 -13 -22 -25 -24 -31 -46 -47 -56 8 -15 -16 -25 -22 -23 -28 -46 -47 -56 * The integral attenuation of filters and rotary heat exchanger has been taken into account. ** Total sound power level emitted to the surroundings is calculated as the sum of the levels in the supply air and the extract air. 70 We reserve the right to alter specifications. 20160422 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 14 Delivery and Transport within the Site The GOLD RX 14 is always supplied as one unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. Upward Upward Forward Forward The three sections are joined together by bolts and the electrical and control cables have quick connectors. Fan arrangement 2 Fan arrangement 1 The air handling unit is delivered on wooden beams. Right-hand version Duct connection options A: Specify right-hand or left-hand version when ordering! If the air handling unit is supplied with all the end connection panels, the version can be changed at the building site by selecting the appropriate version in the hand-held micro terminal. Upward Upward Forward Forward B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when placing orders! Fan arrangement 1 C: Specify upper fan outlet for upward air discharge when placing orders (not for outdoor units). Fan arrangement 2 Left-hand version D: Specify when placing orders whether the unit shall have an air intake from above for outdoor air or extract air. (not for units installed outdoors). Outside air Supply air Extract air Exhaust air Power connection 403 E 91 91 M GOLD GOLD M 50 52 50 52 50 50 The dimension print shows the connection configuration for fan arrangement 1. For fan arrangement 2 the connections are mirror-inverted. * The air handling unit is supplied without end connection panel if a duct accessory housed in an insulated casing will be connected. Size A B C D E F G H I J K L M Weight, kg 14 765 1400 1136 550 208 400 1000 1395 298 109 200 2080 188 521-589 Division into sections for transport A D+19 mm A Clear Space for Inspection The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight: A = 175-209 kg, D = 171 kg. A clear space of 900 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Power connection 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A Rated data per fan Rated data per fan Motor shaft power: 1.6 alt. 2.4 kW, motor control system: 3 x 400 V, 50 Hz 20160422 We reserve the right to alter specifications. 71 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 20 Airflow, m3/h SFP v 2.5 2.0 1.5 Extract air fan Available total pressure rise, Pa Ca Ca 2 p. p. va va r. 2 r. 1 1 L w,tot 70dB 75 80 85 Supply air fan Ca Ca p. p. va va r. 2 r. 1 1 2 L w,tot 70dB 75 80 85 Airflow, m3/s The lower limit for the airflow when the unit is operating in the airflow regulation mode. The limit line for Ecodesign 2018 is calculated with capacity variant 2 and full face end connection panels (accessories). The mean value for supply air and extract air must be within the limit line. The air handling unit complies with requirements to Ecodesign 2016. Other values in diagrams are calculated for air handling units with standard end connection panels. Recommended working range for sizing. Permissible operating range when the fan is controlled to operate at a lower speed. The lower limit for the airflow when the unit is operating in the airflow regulation mode; see the black broken line in the diagram. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). Limit line, Ecodesign, 2018 Min. and Max. Airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The practical flow limits are determined by the external pressure drop. Size 20 Min. airflow (on airflow regulation) m3/s m3/h 1080 0.30 Max. airflow m3/h 7560 m3/s 2.1 Correction factors KOK , dB Sound path To outlet duct To inlet duct* To air handling unit surroundings** Octave band, No. / mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 1 -4 -9 -7 -5 -8 -9 -11 -11 2 2 -4 -7 -7 -10 -12 -16 -17 1 -9 -10 -10 -21 -29 -32 -36 -33 2 -4 -3 -10 -22 -31 -34 -41 -38 1 -15 -23 -30 -26 -41 -42 -45 -42 2 -9 -18 -30 -28 -43 -45 -50 -48 4 5 6 7 8 500 1000 2000 4000 8000 * The integral attenuation of filters and rotary heat exchanger has been taken into account. ** Total sound power level emitted to the surroundings is calculated as the sum of the levels in the supply air and the extract air. 72 We reserve the right to alter specifications. 20160422 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 20 Delivery and Transport within the Site The GOLD RX 20 is always supplied as one unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. Upward Upward Forward Forward The three sections are joined together by bolts and the electrical and control cables have quick connectors. Fan arrangement 2 Fan arrangement 1 The air handling unit is delivered on wooden beams. Right-hand version Duct connection options A: Specify right-hand or left-hand version when ordering! If the air handling unit is supplied with all the end connection panels, the version can be changed at the building site by selecting the appropriate version in the hand-held micro terminal. Upward Upward Forward Forward B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when placing orders! Fan arrangement 1 C: Specify upper fan outlet for upward air discharge when placing orders (not for outdoor units). Fan arrangement 2 Left-hand version D: Specify when placing orders whether the unit shall have an air intake from above for outdoor air or extract air. (not for units installed outdoors). Outside air Supply air Extract air Exhaust air Power connection 403 E 91 91 M GOLD GOLD M 50 52 50 52 50 50 The dimension print shows the connection configuration for fan arrangement 1. For fan arrangement 2 the connections are mirror-inverted. * The air handling unit is supplied without end connection panel if a duct accessory housed in an insulated casing will be connected. Size A B C D E F G H I J K L M Weight, kg 20 765 1400 1136 550 208 400 1000 1395 298 109 200 2080 188 557-625 Division into sections for transport A D+19 mm A Clear space for inspection The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight: A = 193-227 kg, D = 171 kg. A clear space of 900 mm should be provided in front of the unit and at least 200 mm should be provided above the junction hood. Power connection 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A (capacity variant 1) alt. 16 A (capacity variant 2) Rated data per fan Motor shaft power: 2.4 kW alt. 3.4 kW, motor control system: 3 x 400 V, 50 Hz 20160422 We reserve the right to alter specifications. 73 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 25 Airflow, m3/h SFP v 2.5 2.0 1.5 Extract air fan Available total pressure rise, Pa Ca Ca 2 p. va p. va r. 2 r. 1 1 L w,tot 70dB 75 80 85 90 Supply air fan Ca Ca 2 p. va p. va r. 2 r. 1 1 L w,tot 70dB 75 80 85 Airflow, m3/s The lower limit for the airflow when the unit is operating in the airflow regulation mode. The limit line for Ecodesign 2018 is calculated with capacity variant 2 and full face end connection panels (accessories). The mean value for supply air and extract air must be within the limit line. The air handling unit complies with requirements to Ecodesign 2016. Other values in diagrams are calculated for air handling units with standard end connection panels. Recommended working range for sizing. Permissible operating range when the fan is controlled to operate at a lower speed. The lower limit for the airflow when the unit is operating in the airflow regulation mode; see the black broken line in the diagram. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). Limit line, Ecodesign, 2018 Min. and Max. Airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The practical flow limits are determined by the external pressure drop. Size 25 Min. airflow (on airflow regulation) m3/s m3/h 1080 0,30 Max. airflow m3/h 9000 m3/s 2.50 Correction factors KOK , dB Sound path To outlet duct To inlet duct* To air handling unit surroundings** Octave band, No. / mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 1 -4 -9 -7 -5 -8 -9 -11 -11 2 2 -4 -7 -7 -10 -12 -16 -17 1 -9 -10 -10 -21 -29 -32 -36 -33 2 -4 -3 -10 -22 -31 -34 -41 -38 1 -15 -23 -30 -26 -41 -42 -45 -42 2 -9 -18 -30 -28 -43 -45 -50 -48 4 5 6 7 8 500 1000 2000 4000 8000 * The integral attenuation of filters and rotary heat exchanger has been taken into account. ** Total sound power level emitted to the surroundings is calculated as the sum of the levels in the supply air and the extract air. 74 We reserve the right to alter specifications. 20160422 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 25 Delivery and Transport within the Site The GOLD RX 25 is always supplied as one unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. Upward Upward Forward Forward The three sections are joined together by bolts and the electrical and control cables have quick connectors. Fan arrangement 2 Fan arrangement 1 The air handling unit is delivered on wooden beams. Right-hand version Duct connection options A: Specify right-hand or left-hand version when ordering! If the air handling unit is supplied with all the end connection panels, the version can be changed at the building site by selecting the appropriate version in the hand-held micro terminal. Upward Upward Forward Forward B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when placing orders! Fan arrangement 1 C: Specify upper fan outlet for upward air discharge when placing orders (not for outdoor units). Fan arrangement 2 Left-hand version D: Specify when placing orders whether the unit shall have an air intake from above for outdoor air or extract air. (not for units installed outdoors). Outside air Supply air Extract air Exhaust air Power connection 403 E 91 91 M GOLD GOLD M 50 52 50 52 50 50 The dimension print shows the connection configuration for fan arrangement 1. For fan arrangement 2 the connections are mirror-inverted. * The air handling unit is supplied without end connection panel if a duct accessory housed in an insulated casing will be connected. Size A B C D E F G H I J K L M Weight, kg 25 835 1600 1336 550 193 500 1200 1595 298 94 200 2220 203 666-746 Division into sections for transport A D+19 mm A Clear Space for Inspection The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight: A = 225-265 kg, D = 216 kg. A clear space of 900 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Power connection 3-phase, 5-wire cable, 400 V -10/+15%, 50 Hz, 10 A (capacity variant 1) alt. 16 A (capacity variant 2) Rated data per fan Motor shaft power: 2.4 kW alt. 3.4 kW, motor control system: 3 x 400 V, 50 H 20160422 We reserve the right to alter specifications. 75 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 30 Airflow, m3/h SFP v 2.5 2.0 1.5 Extract air fan Available total pressure rise, Pa Ca Ca p. p. va va r. 2 r. 1 1 2 L w,tot 70dB 75 80 85 90 Supply air fan Ca Ca p. p. va va r. 2 r. 1 1 2 L w,tot 70dB 75 80 90 85 Airflow, m3/s The lower limit for the airflow when the unit is operating in the airflow regulation mode. The limit line for Ecodesign is calculated with capacity variant 2 and full face end connection panels (accessories). The mean value for supply air and extract air must be within the limit line. Other values in diagrams are calculated for air handling units with standard end connection panels. Recommended working range for sizing. Permissible operating range when the fan is controlled to operate at a lower speed. The lower limit for the airflow when the unit is operating in the airflow regulation mode; see the black broken line in the diagram. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). Limit line, Ecodesign, 2016 Limit line, Ecodesign, 2018 Min. and Max. Airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The practical flow limits are determined by the external pressure drop. Size 30 Min. airflow (on airflow regulation) m3/s m3/h 1800 0.50 Max. airflow m3/h 11520 m3/s 3.20 Correction factors KOK , dB Sound path To outlet duct To inlet duct* To air handling unit surroundings** Octave band, No. / mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 1 -4 -9 -7 -5 -8 -9 -11 -11 2 2 -4 -7 -7 -10 -12 -16 -17 1 -9 -10 -10 -21 -29 -32 -36 -33 2 -4 -3 -10 -22 -31 -34 -41 -38 1 -15 -23 -30 -26 -41 -42 -45 -42 2 -9 -18 -30 -28 -43 -45 -50 -48 4 5 6 7 8 500 1000 2000 4000 8000 * The integral attenuation of filters and rotary heat exchanger has been taken into account. ** Total sound power level emitted to the surroundings is calculated as the sum of the levels in the supply air and the extract air. 76 We reserve the right to alter specifications. 20160422 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 30 Delivery and Transport within the Site The GOLD RX 30 is always supplied as one unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. Upward Upward Forward Forward The three sections are joined together by bolts and the electrical and control cables have quick connectors. Fan arrangement 2 Fan arrangement 1 The air handling unit is delivered on wooden beams. Right-hand version Duct connection options A: Specify right-hand or left-hand version when ordering! If the air handling unit is supplied with all the end connection panels, the version can be changed at the building site by selecting the appropriate version in the hand-held micro terminal. Upward Upward Forward Forward B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when placing orders! Fan arrangement 1 C: Specify upper fan outlet for upward air discharge when placing orders (not for outdoor units). Fan arrangement 2 Left-hand version D: Specify when placing orders whether the unit shall have an air intake from above for outdoor air or extract air. (not for units installed outdoors). Outside air Supply air Extract air Exhaust air Power connection 403 E 91 91 M GOLD GOLD M 50 52 50 52 50 50 The dimension print shows the connection configuration for fan arrangement 1. For fan arrangement 2 the connections are mirror-inverted. * The air handling unit is supplied without end connection panel if a duct accessory housed in an insulated casing will be connected. Size A B C D E F G H I J K L M Weight, kg 30 835 1600 1336 550 193 500 1200 1595 298 94 200 2220 203 706-786 Division into sections for transport A D+19 mm A Clear space for inspection The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight: A = 245-285 kg, D = 216 kg. A clear space of 900 mm should be provided in front of the unit and at least 200 mm should be provided above the junction hood. Power connection 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 20 A Rated data per fan Motor shaft power: 4.0 kW alt. 5.0 kW, motor control system: 3 x 400 V, 50 Hz 20160422 We reserve the right to alter specifications. 77 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 35 Airflow, m3/h SFP v 2.5 2.0 1.5 Extract air fan Available total pressure rise, Pa Ca Ca p. p. va va r. 1 r. 2 1 2 L w,tot 70dB 75 80 85 90 Supply air fan Ca Ca p. 1 2 L w,tot 70dB 75 80 p. va va r. 2 r. 1 85 90 Airflow, m3/s The lower limit for the airflow when the unit is operating in the airflow regulation mode. The limit line for Ecodesign 2018 is calculated with capacity variant 2 and full face end connection panels (accessories). The mean value for supply air and extract air must be within the limit line. The air handling unit complies with requirements to Ecodesign 2016. Other values in diagrams are calculated for air handling units with standard end connection panels. Recommended working range for sizing. Permissible operating range when the fan is controlled to operate at a lower speed. The lower limit for the airflow when the unit is operating in the airflow regulation mode; see the black broken line in the diagram. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). Limit line, Ecodesign, 2018 Min. and Max. Airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The practical flow limits are determined by the external pressure drop. Size 35 Min. airflow (on airflow regulation) m3/s m3/h 1800 0,50 Max. airflow m3/h 14040 m3/s 3.90 Correction factors KOK , dB Sound path To outlet duct To inlet duct* To air handling unit surroundings** Octave band, No. / mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 1 -4 -9 -7 -5 -8 -9 -11 -11 2 2 -4 -7 -7 -10 -12 -16 -17 1 -9 -10 -10 -21 -29 -32 -36 -33 2 -4 -3 -10 -22 -31 -34 -41 -38 1 -15 -23 -30 -26 -41 -42 -45 -42 2 -9 -18 -30 -28 -43 -45 -50 -48 4 5 6 7 8 500 1000 2000 4000 8000 * The integral attenuation of filters and rotary heat exchanger has been taken into account. ** Total sound power level emitted to the surroundings is calculated as the sum of the levels in the supply air and the extract air. 78 We reserve the right to alter specifications. 20160422 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 35 Delivery and Transport within the Site Upward Upward Forward The GOLD RX 35 is always supplied as one unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. Forward The three sections are joined together by bolts and the electrical and control cables have quick connectors. The air handling unit is delivered on wooden beams. Fan arrangement 1 Fan arrangement 2 Right-hand version Duct connection options A: Specify right-hand or left-hand version when ordering! If the air handling unit is supplied with all the end connection panels, Upward the version can be changed at the building site by selecting the Forward appropriate version in the hand-held micro terminal. Upward Forward B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when placing orders! C: Specify upper fan outlet for upward air discharge when placing orders (not for outdoor units). Fan arrangement 1 Fan arrangement 2 Left-hand version Outside air Supply air Extract air Exhaust air Power connection 34 M GOLD GOLD M 50 52 50 52 50 50 The dimension print shows the connection configuration for fan arrangement 1. For fan arrangement 2 the connections are mirror-inverted. * The air handling unit is supplied without end connection panel if a duct accessory housed in an insulated casing will be connected. Size A B C D E F G H I J K L M Weight, kg 35 948 1990 1726 550 200 600 1400 1985 392 153 295 2446 240 956-1070 Division into sections for transport A D+19 mm A Clear space for inspection The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight: A = 322-379 kg, D = 312 kg. A clear space of 900 mm should be provided in front of the unit. Power connection 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 20 A Rated data per fan Motor shaft power: 4.0 kW alt. 5.0 kW, motor control system: 3 x 400 V, 50 Hz 20160422 We reserve the right to alter specifications. 79 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 40 Airflow, m3/h SFP v 2.5 2.0 1.5 Extract air fan Available total pressure rise, Pa Ca Ca 2 p. va p. va r. 2 r. 1 1 L w,tot 75dB 80 85 90 Supply air fan Ca Ca 2 p. 1 L w,tot 75dB 80 va p. va r. 2 r. 1 85 90 Airflow, m3/s The lower limit for the airflow when the unit is operating in the airflow regulation mode. The limit line for Ecodesign is calculated with capacity variant 2 and full face end connection panels (accessories). The mean value for supply air and extract air must be within the limit line. Other values in diagrams are calculated for air handling units with standard end connection panels. Recommended working range for sizing. Permissible operating range when the fan is controlled to operate at a lower speed. The lower limit for the airflow when the unit is operating in the airflow regulation mode; see the black broken line in the diagram. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). Limit line, Ecodesign, 2016 Limit line, Ecodesign, 2018 Min. and Max. Airflows Correction factors KOK , dB The flows specified refer to those that can be preset in the hand-held micro terminal. The practical flow limits are determined by the external pressure drop. Size 40 Min. airflow (on airflow regulation) m3/s m3/h 2700 0,75 Max. airflow m3/h 140401/180002 Capacity variant 1. 2 Capacity variant 2. 1 m3/s 3,901/5,002 Octave band, No. / mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 To the outlet duct 1 -4 -9 -7 -5 -8 -9 -11 -11 2 2 -4 -7 -7 -10 -12 -16 -17 To the inlet duct* 1 -9 -10 -10 -21 -29 -32 -36 -33 2 -4 -3 -10 -22 -31 -34 -41 -38 To air handling unit surroundings** 1 -15 -23 -30 -26 -41 -42 -45 -42 2 -9 -18 -30 -28 -43 -45 -50 -48 Sound path 4 5 6 7 8 500 1000 2000 4000 8000 * The integral attenuation of filters and rotary heat exchanger has been taken into account. ** Total sound power level emitted to the surroundings is calculated as the sum of the levels in the supply air and the extract air. 80 We reserve the right to alter specifications. 20160422 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 40 Delivery and Transport within the Site Upward Upward Forward The GOLD RX 40 is always supplied as one unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. Forward The three sections are joined together by bolts and the electrical and control cables have quick connectors. The air handling unit is delivered on wooden beams. Fan arrangement 1 Fan arrangement 2 Right-hand version Duct connection options A: Specify right-hand or left-hand version when ordering! If the air handling unit is supplied with all the end connection panels, Upward the version can be changed at the building site by selecting the Forward appropriate version in the hand-held micro terminal. Upward Forward B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when placing orders! C: Specify upper fan outlet for upward air discharge when placing orders (not for outdoor units). Fan arrangement 1 Fan arrangement 2 Left-hand version Outside air Supply air Extract air Exhaust air Power connection 34 M GOLD GOLD M 50 52 50 52 50 50 The dimension print shows the connection configuration for fan arrangement 1. For fan arrangement 2 the connections are mirror-inverted. * The air handling unit is supplied without end connection panel if a duct accessory housed in an insulated casing will be connected. Size A B C D E F G H I J K L M Weight, kg 40 948 1990 1726 550 200 600 1400 1985 392 153 295 2446 240 1006-1120 Division into sections for transport A D A Clear space for inspection The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight: A = 347-404 kg, D = 312 kg. A clear space of 900 mm should be provided in front of the unit. Power connection 3-phase, 5-wire cable, 400 V -10/+15%, 50 Hz, 20 A (capacity variant 1) alt. 25 A (capacity variant 2) Rated data per fan Motor shaft power: 5.0 kW (3.9 kW*) alt. 6.5 kW, motor control system: 3 x 400 V, 50 Hz *The motor control system limits the power of the take-off to the value specified. 20160422 We reserve the right to alter specifications. 81 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 50 Airflow, m3/h 2.5 SFP v 2.0 1.5 Available total pressure rise, Pa Ca Ca p. va Extract air fan p. va r. 2 r. 1 1 2 L w,tot 75dB 80 85 90 Supply air fan Ca Ca p. va p. va r. 2 r. 1 1 2 L w,tot 75dB 80 85 90 Airflow, m3/s The lower limit for the airflow when the unit is operating in the airflow regulation mode. The diagram shows air handling units including standard the end connection panels. The air handling unit complies with requirements to Ecodesign 2016/2018. Recommended working range for sizing. Permissible operating range when the fan is controlled to operate at a lower speed. The lower limit for the airflow when the unit is operating in the airflow regulation mode; see the black broken line in the diagram. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). Min. and Max. Airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The practical flow limits are determined by the external pressure drop. Size 50 Min. airflow (on airflow regulation) m3/s m3/h 2160 0,60 Max. airflow m3/h 18000 m3/s 5.00 Correction factors KOK , dB Sound path To outlet duct To inlet duct* To air handling unit surroundings** Octave band, No. / mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 1 -4 -9 -7 -5 -8 -9 -11 -11 2 2 -4 -7 -7 -10 -12 -16 -17 1 -9 -10 -10 -21 -29 -32 -36 -33 2 -4 -3 -10 -22 -31 -34 -41 -38 1 -15 -23 -30 -26 -41 -42 -45 -42 2 -9 -18 -30 -28 -43 -45 -50 -48 4 5 6 7 8 500 1000 2000 4000 8000 * The integral attenuation of filters and rotary heat exchanger has been taken into account. ** Total sound power level emitted to the surroundings is calculated as the sum of the levels in the supply air and the extract air. 82 We reserve the right to alter specifications. 20160422 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 50 Delivery and Transport within the Site Upward Upward Forward The GOLD RX 50 is always supplied as one unit. Forward The air handling unit can be split into three sections to facilitate transporting it within the building site. The three sections are joined together by bolts and the electrical and control cables have quick connectors. Fan arrangement 1 The unit is supplied on 100 mm high support feet made of steel. Fan arrangement 2 Right-hand version Duct connection options Upward A: Specify right-hand or left-hand version when ordering! B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when placing orders! Upward Forward Forward C: Specify upper fan outlet for upward air discharge when ordering. (not for units installed outdoors) Fan arrangement 1 Fan arrangement 2 Left-hand version Outside air Supply air Extract air Exhaust air 34 28* GOLD Power connection GOLD 28 76 Supplied on 100 mm high support feet. They can be removed or kept as they are when the unit is in place. The unit has provision for fitting the adjustable support feet. * The air handling unit is supplied without end connection panel if a duct accessory housed in an insulated casing will be connected. Size A B D E F G H I J K L Weight, kg 50 1050 2318 570 150 800 1600 2253 423 115 360 2670 1294-1418 Division into sections for transport A 76 D A Clear Space for Inspection The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight: A = 440-502 kg, D = 414 kg. A clear space of 1,100 mm should be provided in front of the unit. Power connection 3-phase, 5-wire cable, 400 V -10/+15%, 50 Hz, 20 A (capacity variant 1) alt. 32 A (capacity variant 2) Rated data per fan Motor shaft power: 2 x 2.4 kW alt. 2 x 3.4 kW, motor control system: 3 x 400 V, 50 Hz 20160422 We reserve the right to alter specifications. 83 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 60 Airflow, m3/h SFP v 2.5 2.0 1.5 Extract air fan Available total pressure rise, Pa Ca Ca 1 2 L w,tot 75dB 80 p. va 85 p. va r. 2 95 r. 1 90 Supply air fan Ca Ca 1 2 L w,tot 75dB 80 p. va p. va 95 r. 2 r. 1 85 90 Airflow, m3/s The lower limit for the airflow when the unit is operating in the airflow regulation mode. The limit line for Ecodesign is calculated with capacity variant 2 and full face end connection panels (accessories). The mean value for supply air and extract air must be within the limit line. Other values in diagrams are calculated for air handling units with standard end connection panels. Recommended working range for sizing. Permissible operating range when the fan is controlled to operate at a lower speed. The lower limit for the airflow when the unit is operating in the airflow regulation mode; see the black broken line in the diagram. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). Limit line, Ecodesign, 2016 Limit line, Ecodesign, 2018 Min. and Max. Airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The practical flow limits are determined by the external pressure drop. Size 60 Min. airflow (on airflow regulation) m3/s m3/h 3600 1.00 Max. airflow m3/h 23400 m3/s 6.50 Correction factors KOK , dB Sound path To outlet duct To inlet duct* To air handling unit surroundings** Octave band, No. / mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 1 -4 -9 -7 -5 -8 -9 -11 -11 2 2 -4 -7 -7 -10 -12 -16 -17 1 -9 -10 -10 -21 -29 -32 -36 -33 2 -4 -3 -10 -22 -31 -34 -41 -38 1 -15 -23 -30 -26 -41 -42 -45 -42 2 -9 -18 -30 -28 -43 -45 -50 -48 4 5 6 7 8 500 1000 2000 4000 8000 * The integral attenuation of filters and rotary heat exchanger has been taken into account. ** Total sound power level emitted to the surroundings is calculated as the sum of the levels in the supply air and the extract air. 84 We reserve the right to alter specifications. 20160422 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 60 Delivery and Transport within the Site Upward Upward Forward The GOLD RX 60 is always supplied as one unit. Forward The air handling unit can be split into three sections to facilitate transporting it within the building site. The three sections are joined together by bolts and the electrical and control cables have quick connectors. Fan arrangement 1 The unit is supplied on 100 mm high support feet made of steel. Fan arrangement 2 Right-hand version Duct connection options Upward A: Specify right-hand or left-hand version when ordering! B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when placing orders! Upward Forward Forward C: Specify upper fan outlet for upward air discharge when ordering. (not for units installed outdoors). Fan arrangement 1 Fan arrangement 2 Left-hand version Outside air Supply air Extract air Exhaust air 34 28* GOLD Power connection GOLD 28 76 Supplied on 100 mm high support feet. They can be removed or kept as they are when the unit is in place. The unit has provision for fitting the adjustable support feet. * The air handling unit is supplied without end connection panel if a duct accessory housed in an insulated casing will be connected. Size A B D E F G H I J K L Weight, kg 60 1050 2318 570 150 800 1600 2253 423 115 360 2670 1374-1498 Division into sections for transport A 76 D A Clear space for inspection The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight: A = 480-542 kg, D = 414 kg. A clear space of 1,100 mm should be provided in front of the unit. Power connection 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 32 A (capacity variant 1) alt. 50 A (capacity variant 2) Rated data per fan Motor shaft power: 2 x 4.0 kW alt. 2 x 6.5 kW, motor control system: 3 x 400 V, 50 Hz 20160422 We reserve the right to alter specifications. 85 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 70 Airflow, m3/h SFP v 2.5 2.0 1.5 Extract air fan p. Available total pressure rise, Pa Ca va 1 2 L w,tot 75dB 80 85 2 r. Ca p. va r. 1 90 95 Supply air fan Ca p. L w,tot 75dB 80 85 p. 2 r. 1 2 va Ca va r. 1 95 90 Airflow, m3/s The lower limit for the airflow when the unit is operating in the airflow regulation mode. The limit line for Ecodesign 2018 is calculated with capacity variant 2 and full face end connection panels (accessories). The mean value for supply air and extract air must be within the limit line. The air handling unit complies with requirements to Ecodesign 2016. Other values in diagrams are calculated for air handling units with standard end connection panels. Recommended working range for sizing. Permissible operating range when the fan is controlled to operate at a lower speed. The lower limit for the airflow when the unit is operating in the airflow regulation mode; see the black broken line in the diagram. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). Limit line, Ecodesign, 2018 Min. and Max. Airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The practical flow limits are determined by the external pressure drop. Size 70 Min. airflow (on airflow regulation) m3/s m3/h 3600 1,00 Max. airflow m3/h 27000 m3/s 7.50 Correction factors KOK , dB Sound path To outlet duct To inlet duct* To air handling unit surroundings** Octave band, No. / mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 1 -4 -9 -7 -5 -8 -9 -11 -11 2 2 -4 -7 -7 -10 -12 -16 -17 1 -9 -10 -10 -21 -29 -32 -36 -33 2 -4 -3 -10 -22 -31 -34 -41 -38 1 -15 -23 -30 -26 -41 -42 -45 -42 2 -9 -18 -30 -28 -43 -45 -50 -48 4 5 6 7 8 500 1000 2000 4000 8000 * The integral attenuation of filters and rotary heat exchanger has been taken into account. ** Total sound power level emitted to the surroundings is calculated as the sum of the levels in the supply air and the extract air. 86 We reserve the right to alter specifications. 20160422 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 70 Delivery and Transport within the Site Upward Upward Forward The GOLD RX 70 is supplied as two units. The one unit consists of the centre section with heat exchanger and the fan/filter section where the fan is mounted in the upper level. The other unit consists of a fan/filter section in which the fan is placed in the lower level. The air handling unit can be split into three sections to facilitate transporting it within the building site. Forward Fan arrangement 1 Fan arrangement 2 Right-hand version The three sections are joined together by bolts and the electrical and control cables have quick connectors. Upward The unit is supplied on 100 mm high support feet made of steel. Upward Forward Forward Duct connection options A: Specify right-hand or left-hand version when ordering! B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when placing orders! Fan arrangement 1 Fan arrangement 2 Left-hand version C: Specify upper fan outlet for upward air discharge when ordering. (not for units installed outdoors) Outside air Supply air Extract air Exhaust air 52* Power connection GOLD GOLD 52 76 Supplied on 100 mm high support feet. They can be removed or kept as they are when the unit is in place. The unit has provision for fitting the adjustable support feet. * The air handling unit is supplied without end connection panel if a duct accessory housed in an insulated casing will be connected. Size A B D E F G H I J K L Weight, kg 70 1275 2637 570 164 1000 1800 2640 319 161 419 3120 2059-2211 Division into sections for transport A 76 D A Clear Space for Inspection The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight: A = 740-816 kg, D = 579 kg. A clear space of 1,100 mm should be provided in front of the unit. Power connection 3-phase, 5-wire cable, 400 V -10/+15%, 50 Hz, 32 A (capacity variant 1) alt. 50 A (capacity variant 2) Rated data per fan Motor shaft power: 2 x 4.0 kW alt. 2 x 6.5 kW, motor control system: 3 x 400 V, 50 Hz 20160422 We reserve the right to alter specifications. 87 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 80 Airflow, m3/h SFP v 2.5 2.0 1.5 Extract air fan Ca va Available total pressure rise, Pa p. 2 r. Ca p. va r. 1 1 2 L w,tot 75dB 80 85 90 95 Supply air fan Ca Ca p. va 1 2 L w,tot 75dB 80 85 p. va r. 1 r. 2 95 90 Airflow, m3/s The lower limit for the airflow when the unit is operating in the airflow regulation mode. The limit line for Ecodesign is calculated with capacity variant 2 and full face end connection panels (accessories). The mean value for supply air and extract air must be within the limit line. Other values in diagrams are calculated for air handling units with standard end connection panels. Recommended working range for sizing. Permissible operating range when the fan is controlled to operate at a lower speed. The lower limit for the airflow when the unit is operating in the airflow regulation mode; see the black broken line in the diagram. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). Limit line, Ecodesign, 2016 Limit line, Ecodesign, 2018 Min. and Max. Airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The practical flow limits are determined by the external pressure drop. Size 80 Min. airflow (on airflow regulation) m3/s m3/h 5400 1.50 Max. airflow m3/h 34200 m3/s 9.50 Correction factors KOK , dB Sound path To outlet duct To inlet duct* To air handling unit surroundings** Octave band, No. / mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 1 -4 -9 -7 -5 -8 -9 -11 -11 2 2 -4 -7 -7 -10 -12 -16 -17 1 -9 -10 -10 -21 -29 -32 -36 -33 2 -4 -3 -10 -22 -31 -34 -41 -38 1 -15 -23 -30 -26 -41 -42 -45 -42 2 -9 -18 -30 -28 -43 -45 -50 -48 4 5 6 7 8 500 1000 2000 4000 8000 * The integral attenuation of filters and rotary heat exchanger has been taken into account. ** Total sound power level emitted to the surroundings is calculated as the sum of the levels in the supply air and the extract air. 88 We reserve the right to alter specifications. 20160422 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 80 Delivery and Transport within the Site Upward Upward Forward The GOLD RX 80 is supplied as two units. The one unit consists of the centre section with heat exchanger and the fan/filter section where the fan is mounted in the upper level. The other unit consists of a fan/filter section in which the fan is placed in the lower level. The air handling unit can be split into three sections to facilitate transporting it within the building site. Forward Fan arrangement 1 Fan arrangement 2 Right-hand version The three sections are joined together by bolts and the electrical and control cables have quick connectors. Upward The unit is supplied on 100 mm high support feet made of steel. Upward Forward Forward Duct connection options A: Specify right-hand or left-hand version when ordering! B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when placing orders! Fan arrangement 1 Fan arrangement 2 Left-hand version C: Specify upper fan outlet for upward air discharge when ordering. (not for units installed outdoors) Outside air Supply air 52* Extract air Exhaust air 137 Power connection Applies to capacity variant 2 only GOLD GOLD 52 76 Supplied on 100 mm high support feet. They can be removed or kept as they are when the unit is in place. The unit has provision for fitting the adjustable support feet. * The air handling unit is supplied without end connection panel if a duct accessory housed in an insulated casing will be connected. Size A B D E F G H I J K L Weight, kg 80 1275 2637 570 164 1000 1800 2640 319 161 419 3120 2159-2435 Division into sections for transport A 76 D A Clear Space for Inspection The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight: A = 790-928 kg, D = 579 kg. A clear space of 1,100 mm should be provided in front of the unit. Power connection 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 50 A (capacity variant 1) alt. 80 A (capacity variant 2) Rated data per fan Motor shaft power: 2 x 6.5 kW alt. 2 x 10 kW, motor control system: 3 x 400 V, 50 Hz 20160422 We reserve the right to alter specifications. 89 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, size 100 Airflow, m3/h SFP v 2.5 2.0 1.5 Extract air fan p. Available total pressure rise, Pa Ca va 2 r. Ca p. va 1 2 L w,tot 75dB 80 85 r. 1 90 95 Supply air fan Ca p. va r. 2 Ca p. va 1 r. 1 2 L w,tot 75dB 80 85 90 95 Airflow, m3/s The lower limit for the airflow when the unit is operating in the airflow regulation mode. The diagram shows air handling units including standard the end connection panels. The air handling unit complies with requirements to Ecodesign 2016/2018. Recommended working range for sizing. Permissible operating range when the fan is controlled to operate at a lower speed. The lower limit for the airflow when the unit is operating in the airflow regulation mode; see the black broken line in the diagram. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). Min. and Max. Airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The practical flow limits are determined by the external pressure drop. Size 100 Min. airflow (on airflow regulation) m3/s m3/h 5400 1,50 Max. airflow m3/h 39 600 m3/s 11.0 Correction factors KOK , dB Octave band, no./mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 To the outlet duct 1 -4 -9 -7 -5 -8 -9 -11 -11 2 2 -4 -7 -7 -10 -12 -16 -17 To the inlet duct* 1 -9 -10 -10 -21 -29 -32 -36 -33 2 -4 -3 -10 -22 -31 -34 -41 -38 To air handling unit surroundings** 1 -15 -23 -30 -26 -41 -42 -45 -42 2 -9 -18 -30 -28 -43 -45 -50 -48 Sound path 4 5 6 7 8 500 1000 2000 4000 8000 * The integral attenuation of filters and rotary heat exchanger has been taken into account. ** Total sound power level emitted to the surroundings is calculated as the sum of the levels in the supply air and the extract air. 90 We reserve the right to alter specifications. 20160422 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, size 100 Upward Delivery and Transport within the Site Upward Forward The GOLD RX 100 is supplied in five separate sections: two fan sections, two filter sections and one heat exchanger section. The heat exchanger section can also be supplied split into two casing sections and rotor, in which case the rotor is supplied tilted in a transport cradle (transport height = 2,930 mm, minimum transport width = 2,350 mm). After the heat exchanger has been assembled, if required, the five sections are installed at the building site. Forward Fan arrangement 1 Fan arrangement 2 Right-hand version Upward The five sections are joined together by bolts and the electrical and control cabling between the parts have quick-fit connectors. Upward Forward Forward Duct connection options A: Specify right-hand or left-hand version when ordering! B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when placing orders. Fan arrangement 1 Fan arrangement 2 Left-hand version C: Specify upper fan outlet for upward air discharge when ordering. (not for units installed outdoors) N.B.! Duct connection size: 2500 x 800 mm. Outdoor air Supply air Extract air Exhaust air 137 M 56* N N O P * The air handling unit is supplied without end connection panel if a duct accessory housed in an insulated casing will be connected. GOLD GOLD P Power connection GOLD 45 56 1048 122 77 1000 1048 77 3186 Size A B D E F G H I J K L M N O P Weight, kg 100 1126 3340 1070 191 1200 2400 3440 520 210 470 3322 800 170 2500 1720 3540-3900 Transport at building site, dim. and weights filter and fan sections See dimensions A and P in the table above. Weight: fan section = 713-834 kg, filter section = 470-529 kg. Heat exchanger section, mounted See dimensions D and H in the table above. Weight: heat exchanger section = 1,174 kg. Heat exchanger section, two casing sections + rotor See transport dimensions in the Delivery and at-site transport section above. Weight: casing lower section = 494 kg, casing upper section = 270 kg, rotor = 410 kg, transport cradle = 190 kg Clear space for inspection A clear space of 1,000 mm should be provided in front of the unit. Power connection 3-phase, 5-wire cable, 400 V -10/+15%, 50 Hz, 50 A (capacity variant 1) alt. 80 A (capacity variant 2) Rated data per fan Motor shaft power: 2 x 6.5 kW alt. 2 x 10 kW, motor control system: 3 x 400 V, 50 Hz 20160422 We reserve the right to alter specifications. 91 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, size 120 Airflow, m3/h SFP v 2.5 2.0 1.5 Extract air fan Ca va Available total pressure rise, Pa p. 2 2 r. Ca p. va r. 1 1 L w,tot 80dB 85 90 95 Supply air fan Ca Ca 2 p. va p. va r. 2 r. 1 1 L w,tot 80dB 85 90 95 Airflow, m3/s The lower limit for the airflow when the unit is operating in the airflow regulation mode. The limit line for Ecodesign is calculated with capacity variant 2 and full face end connection panels (accessories). The mean value for supply air and extract air must be within the limit line. Other values in diagrams are calculated for air handling units with standard end connection panels. Recommended working range for sizing. Permissible operating range when the fan is controlled to operate at a lower speed. The lower limit for the airflow when the unit is operating in the airflow regulation mode; see the black broken line in the diagram. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). Limit line, Ecodesign, 2016 Limit line, Ecodesign, 2018 Min. and Max. Airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The practical flow limits are determined by the external pressure drop. Size 120 Min. airflow (on airflow regulation) m3/s m3/h 9000 2.50 Max. airflow m3/h 50 400 m3/s 14.0 Correction factors KOK , dB Octave band, no./mid-frequency, Hz Range in the diagram 1 2 3 63 125 250 To the outlet duct 1 -4 -9 -7 -5 -8 -9 -11 -11 2 2 -4 -7 -7 -10 -12 -16 -17 To inlet duct* 1 -9 -10 -10 -21 -29 -32 -36 -33 2 -4 -3 -10 -22 -31 -34 -41 -38 1 -15 -23 -30 -26 -41 -42 -45 -42 2 -9 -18 -30 -28 -43 -45 -50 -48 Sound path To air handling unit surroundings** 4 5 6 7 8 500 1000 2000 4000 8000 * The integral attenuation of filters and rotary heat exchanger has been taken into account. ** Total sound power level emitted to the surroundings is calculated as the sum of the levels in the supply air and the extract air. 92 We reserve the right to alter specifications. 20160422 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, size 120 Upward Delivery and Transport within the Site Upward Forward The GOLD RX 120 is supplied in five separate sections: two fan sections, two filter sections and one heat exchanger section. The heat exchanger section can also be supplied split into two casing sections and rotor, in which case the rotor is supplied tilted in a transport cradle (transport height = 2,930 mm, minimum transport width = 2,350 mm). After the heat exchanger has been assembled, if required, the five sections are installed at the building site. Forward Fan arrangement 1 Fan arrangement 2 Right-hand version Upward The five sections are joined together by bolts and the electrical and control cabling between the parts have quick-fit connectors. Upward Forward Forward Duct connection options A: Specify right-hand or left-hand version when ordering! B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when placing orders. Fan arrangement 1 Fan arrangement 2 Left-hand version C: Specify upper fan outlet for upward air discharge when ordering. (not for units installed outdoors) N.B.! Duct connection size: 2500 x 800 mm. Outdoor air Supply air Extract air Exhaust air 137 M 56* N N O P * The air handling unit is supplied without end connection panel if a duct accessory housed in an insulated casing will be connected. GOLD GOLD P Power connection GOLD 45 56 1048 122 77 1000 1048 77 3186 Size A B D E F G H I J K L M N O P Weight, kg 120 1126 3340 1070 191 1200 2400 3440 520 210 470 3322 800 170 2500 1720 3746-4168 Transport at building site, dim. and weights filter and fan sections See dimensions A and P in the table above. Weight: fan section = 816-968 kg, filter section = 470-529 kg. Heat exchanger section, mounted See dimensions D and H in the table above. Weight: heat exchanger section = 1,174 kg. Heat exchanger section, two casing sections + rotor See transport dimensions in the Delivery and at-site transport section above. Weight: casing lower section = 494 kg, casing upper section = 270 kg, rotor = 410 kg, transport cradle = 190 kg Clear space for inspection A clear space of 1,000 mm should be provided in front of the unit. Power connection 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 80 A (capacity variant 1) alt. 125 A (capacity variant 2) Rated data per fan Motor shaft power: 3 x 6.5 kW alt. 3 x 10 kW, motor control system: 3 x 400 V, 50 Hz 20160422 We reserve the right to alter specifications. 93