Job______________________________________________ Type_____________________________________________ Catalog #
Construction
Application
• die-formed code gauge cold rolled steel
• smoothly contoured diffuser for soft, low brightness illumination and floating, cloudof-light effect. • suitable for commercial,
housing. ballast cover easily removed without tools. knockouts provided on housing top for mounting and electrical connections.
• fully luminous, translucent white, molded, .080” acrylic lens provides even, low brightness lighting. • frameless diffuser hinges from either side of housing in a lift-and-shift manner.
institutional and residential interiors.
Finish
Electrical
• all metal parts pretreated with a phosphate bonding
• Standard ballast is electronic, hpf,
process and post-painted with
class p and ul listed for universal voltage.
an electrostatically applied
listed
high temperature baked white enamel for superior quality and
Example: SL23214-EO9CL
Series
Lmps
SL
2
28-28w T5 32-32w T8 54-54wT5HO
14
2
28-28w T5 32-32w T8 54-54wT5HO
54
14-14w T5 17-17w T8 24-24w T5HO 4T-40 wTwinTube U2-31w U1 5/8 c/c
62
14-14w T5 17-17w T8 24-24w T5HO 4T-40 wTwin Tube U2-31w U1 5/8 c/c U6-32w U6
22
28-28w T5 32-32w T8 54-54w T5HO
64
28-28w T5 32-32w T8 54-54w T5HO
24
___ 2
2,4 2,3 2 ___ 2,4
2,3,4
listed
• suitable for damp locations. • i.b.e.w. labeled.
durability.
ORDERING GUIDE
SL SERIES
Watts
Stratolume Surface Luminaires Options
Fixt
Ballast: 1 or 2 lamps: EO - one ballast 3+ lamps: EO - two ballast,wired inboard/outboard (or customer specified) CO - one ballast Specific Ballasts: HL – high ballast factor LW – low ballast factor PSP – program start, parallel wiring PRS - programmed rapid start ballast (std on T5) Dimming: DL - dimming, lutron DA - dimming, advance DO - dimming, osram DU - dimming, utl (specify vendor ’s product catalog decription) Voltage: 1 - 120v 7 - 480v 4 - 277v 8 - 347-480 5 - 347v 9- 120-277 Lens: CL - translucent white cloud
2G-20 gauge crs hsg. and ends. TP2 - tamper resistant lens retainer Clips (2, diagonal corners) TP4 - tamper resistant lens retainer Clips (4, one each corner) Emergency Ball asts: EM1 - 1 lamp(500-600L) EM1A - 1 lamp(350-450L) EM2 - 2 lamps(1100-1400L) EM2A - 2 lamps(600-700L) EM3 - 1 lamp
LUMAX INDUSTRIES, INC. Chestnut Avenue & Fourth Street Altoona, PA 16603-0991 814-944-2537 Fax 814-944-6413 www.lumaxlighting.com
SL
Series
PHOTOMETRIC DATA Typical initial footcandles, with readings at work plane height of 30”, spaced 2 ft. apart. Fixture Size: 54 Catalog No.: SL24054-BE1CL Lamps: Two F40
Room Size: 14 ft. x 14 ft. Ceiling Heigth: 8 ft. 6’
4
5
7
8
7
5
4
4’
5
8
13
16
13
8
5
2’
7
12
20
27
20
12
7
0’
8
14
25
34
25
14
8
2’
7
12
20
27
20
12
7
4’
5
8
13
16
13
8
5
6’
4
5
7
8
7
5
4
6’
4’
2’
0’
2’
4’
6’
Fixture Size: 62 Catalog No.: SL24T62-BH1CL Lamps: Two 4T Biax 6’
6
4’ 2’ 0’ 2’ 4’ 6’
7
8
9
8
8
11
15
18
9
15
24
30
10
18
32
39
9 8 6 6’
SL 22 26” x 26”
15 11 7 4’
24 15 8 2’
30 18 9 0’
7
6
15
11
8
24
15
9
32
18
10
24 15 8 2’
15 11 7 4’
9 8 6 6’
Fixture Size: 64 Catalog No.: SL44064-BE1CL Lamps: Four F40 6’
9
11
14
16
14
11
9
4’
12
17
25
31
25
17
12
2’
14
25
44
54
44
25
14
0’
17
30
53
68
53
30
17
2’
14
25
44
54
44
25
14
4’
12
17
25
31
25
17
12
6’
9
11
14
16
14
11
9
6’
4’
2’
0’
2’
4’
6’
SL 64 17” x 48” SL 54 11 3/4” x 48”
SL 62 17” x 24” SL 24 26” x 48”
SL 14 141/2” x 48”
DIMENSIONS
Specifications and dimensional data subject to change without notice. 2 Lamp 54 No. 98