Transcript
Products Specification SPECIFICATION MODEL: ISSUE DATE : COMMON/UNITE
PREPARE
USED IN: 2007-6-16 9:48 DOC. NO:
ITEM
CHECK
REV.:
1.0
3PX0-A7045 Smart 3-Stages SLA Battery charger UNIT SPECIFICATION
INPUT 01 Rating Input Voltage 02 Input voltage range 03 Rating Input Current 04 Max. input power OUTPUT 05 Rating output voltage 06 Output voltage range 07 Suit with Battery type 08 Charging current ( stage 1) 09 Charging voltage (stage 2) Floating voltage (stage 3) 10 Cut-off current(stage 2→3) 11 Typical charging time 12 Max. output power 13 Hold-on time 14 Ripple current 15 Charge finish condition 16 LED color 17 Output protect 18 Efficiency Environment 19 Operate temperature 20 Operate humidity 21 Storage temperature 22 Storage humidity 23 Cooling 24 Temperature factor 25 Vibration resistance 26 Impact resistance Mechanical 27 Weight 28 Size 29 Connectors Safety 30 Max. temperature rise 31 Safety standards 32 EMC standard 33 MTBF 34 Limited power source 35 ESD 36 Hi-Pot Insulation
V ac V ac A W
100~240Vac 50/60Hz 90~264Vac 1.2Arms 90
42V 30VDC ~ 45VDC 36V 8~12 Ah VRLA A 1.85± 0.15@38V V 44.2V +-0.2V V 41.7V+-0.3V A <0.41+-0.04A hour 8 W 70W ms NC mA 100 V>44V + I<0.4A Red: charging Green: finish/idle OCP & OVP % 80%
APPROVE
PAGE:
1 OF 1
REMARK
INPUT:220V OUTPUT:Full load
V dc V dc
°C %RH °C %RH %
-10 ~ +40 < +90 -40 ~ +70 0 ~ +95 Natural convection -5MM/50HZ/600S 1 meter drop test >= 3 times
g mm -
550 129X91X68 Defined when order
°C hrs VA kV V
< 40 on casing IEC335-2-29 EN55014 30000 8.0 i/p to o/p: 3000 (1 min.)
Input: 220Vac Output: Full load Input: 220Vac Output: Full load
At max. load Full load & natural convection. Relative humidity, non-condensing. Relative humidity, non-condensing.
Non-operating condition. Non-operating condition.
Casing only
At any line and Max. Load
For final unit, cut-off current =10mA