Transcript
M-SERIES
SUBMITTAL DATA: SLZ-KA09NA
9,000 BTU/H CEILING-CASSETTE INDOOR UNIT FOR MXZ MULTI-ZONE HEAT-PUMP SYSTEMS
Job Name: System Reference:
Date:
SPECIFICATIONS Cooling Capacity* . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8,400 Btu/h Heating Capacity at 47°F* . . . . . . . . . . . . . . . . . . . . . 10,900 Btu/h * Rating Conditions per AHRI Standard Cooling | Indoor: 80º F (27º C) DB / 67º F (19º C) WB Cooling | Outdoor: 95º F (35º C) DB / 75º F (24º C) WB Heating at 47º F | Indoor: 70º F (21º C) DB / 60º F (16º C) WB Heating at 47º F | Outdoor: 47º F (8º C) DB / 43º F (6º C) WB SLZ-KA09NA
GENERAL FEATURES • Four-way 2'x2' ceiling-cassette indoor unit for ceiling recessed applications • Built-in drain mechanism for condensate removal; lifts to 19-11/16" • Wide air-flow pattern for better air distribution • Design features ventilation air intake knockout • Long-life air filter included with indoor unit • Indoor unit powered from outdoor unit using A-Control • Choice of fan speed: Low, Medium, High • Automatic restart following a power outage • Limited warranty: five years parts and seven years compressors ACCESSORIES Indoor Unit □□ Grille (SLP-15AAUW; required - shipped with unit)
Controller Options
□□ Wireless Controller (MHK1) □□ Wired Remote Controller (PAR-32MAA-J) □□ Wireless Interface for kumo cloud™ (PAC-WHS01WF-E) □□ Thermostat Interface (PAC-US444CN-1) □□ Hand-held Wireless Remote Controller (PAR-FL32MA; req.PAR-FA32MA-E) □□ Wireless Signal Receiver Module PAR-FA32MA (for PAR-FL32MA-E)
(For data on specific indoor units [all ducted, all non-ducted, and both ducted and non-ducted] combinations, see the MXZ Technical and Service Manual.) Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. Electrical Requirements Power Supply . . . . . . . . . . . . . . . . . . . 208 / 230V, 1-Phase, 60 Hz MCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 A Voltage Indoor - Outdoor S1-S2 . . . . . . . . . . . . . . . . . . . . . . . AC 208 / 230V Indoor - Outdoor S2-S3 . . . . . . . . . . . . . . . . . . . . . . . . . . . DC ±24V Fan Motor (ECM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.23 F.L.A. Airflow (Lo - Med - Hi) . . . . . . . . . . . . . . . . . . 280 - 320 - 350 Dry CFM 250 - 290 - 320 Wet CFM Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . Polypropylene Honeycomb Sound Pressure Level (Lo - Med - Hi) . . . . . . . . . 29 - 32 - 38 dB(A) DIMENSIONS W D H
UNIT INCHES / MM 22-7/16 / 570 22-7/16 / 570 9-1/4 / 235
GRILLE INCHES / MM 25-5/8 / 650 25-5/8 / 650 13/16 / 20
Weight (Unit/Grille) Lbs.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 / 7 kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16.5 / 3 External Finish (Unit/Grille) . . . . . . . . . . Galvanized-steel Sheets / Munsell 6.4Y 8.9 / 0.4 Field Drainpipe Size O.D. . . . . . . . . . . . . . . . . . . . . . 1-1/4” / 32 mm Refrigerant Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R410A Refrigerant Pipe Size O.D. Gas Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/8" / 9.52 mm Liquid Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4" / 6.35 mm Connection Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flared
Specifications are subject to change without notice.
© 2016 Mitsubishi Electric US, Inc.
DIMENSIONS: SLZ-KA09NA
Detail drawing of fresh air intake
Ceiling hole
Fresh air intake
12
1-7/32(31) 3-7/16(87)
2-7/32(56)
Grille
Ceiling surface
1-1/16
Terminal block
+3/16 (27 +5) 0 0 25/32(20)
7-19/32(193)
Refrigerant pipe (liquid)
Wiring entry
7-5/32(182)
Drain pipe VP-25 connection (O.D. 1-1/4( 32)) Suspension bolt M10 or W3/8
9-1/16(230)
1-7/8(48)
7-15/16(202)
8-3/16(208)
Refrigerant 21/32(17) pipe (gas)
19/32~1-15/32(15~37)
22-11/16~24-13/32(576~620) Ceiling hole
9-1/4(235)
2-1/14(57)
Ceiling surface
7-27/32(199) 13-27/32(352) 13-3/16(335)
1-1/2~2-9/32(38~58) Suspension bolt lower edge
2-19/32(66)
2-7/8( 73.4) Cut out hole
0
22-7/16(570)
3-21/32(93)
25-19/32(650) 11-27/32(301) Air outlet hole
1-3/8(35)
4-3/4(121)
22-7/16(570)
13-3/16(335)
22-11/16~24-13/32(576~620)
16-17/32(420) Suspension bolt pitch
Suspension bolt pitch
19/32~1-15/32(15~37)
Refrigerent pipe (liquid)
Refrigerent pipe (gas)
SLZ-KA09NA
1/4 inch ( 6.35mm) flared connection
3/8 inch ( 9.52mm) flared connection
SLZ-KA12NA
1/4 inch ( 6.35mm) flared connection
3/8 inch ( 9.52mm) flared connection
SLZ-KA15NA
1/4 inch ( 6.35mm) flared connection
1/2 inch ( 12.7mm) flared connection
Models Brand label
2-5/32(55)
Grille V/M
Drain hole V/M
Auto vane 14-27/32(377) Air intake hole
11-27/32(301) Air outlet hole
25-19/32(650)
1(25)
3- 1/8( 2.8) Burring hole
20-7/8(530)
120
19/32~1-15/32(15~37)
3-15/16( 100)
4-21/32(118)
19/32~1-15/32(15~37)
Unit : inch (mm)
V/M V/M
Air intake grille Vane motor
14-27/32(377) Air intake hole 1-3/8(35)
2-5/32(55)
1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com
FORM# SLZ-KA09NA for MXZ MULTI-ZONE SYSTEMS - 201604 Specifications are subject to change without notice.
© 2016 Mitsubishi Electric US, Inc.