Slz-ka09na For Mxz Multi-zone Systems

   EMBED


Share

Transcript

M-SERIES SUBMITTAL DATA: SLZ-KA09NA 9,000 BTU/H CEILING-CASSETTE INDOOR UNIT FOR MXZ MULTI-ZONE HEAT-PUMP SYSTEMS Job Name: System Reference: Date: SPECIFICATIONS Cooling Capacity* . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8,400 Btu/h Heating Capacity at 47°F* . . . . . . . . . . . . . . . . . . . . . 10,900 Btu/h * Rating Conditions per AHRI Standard Cooling | Indoor: 80º F (27º C) DB / 67º F (19º C) WB Cooling | Outdoor: 95º F (35º C) DB / 75º F (24º C) WB Heating at 47º F | Indoor: 70º F (21º C) DB / 60º F (16º C) WB Heating at 47º F | Outdoor: 47º F (8º C) DB / 43º F (6º C) WB SLZ-KA09NA GENERAL FEATURES • Four-way 2'x2' ceiling-cassette indoor unit for ceiling recessed applications • Built-in drain mechanism for condensate removal; lifts to 19-11/16" • Wide air-flow pattern for better air distribution • Design features ventilation air intake knockout • Long-life air filter included with indoor unit • Indoor unit powered from outdoor unit using A-Control • Choice of fan speed: Low, Medium, High • Automatic restart following a power outage • Limited warranty: five years parts and seven years compressors ACCESSORIES Indoor Unit □□ Grille (SLP-15AAUW; required - shipped with unit) Controller Options □□ Wireless Controller (MHK1) □□ Wired Remote Controller (PAR-32MAA-J) □□ Wireless Interface for kumo cloud™ (PAC-WHS01WF-E) □□ Thermostat Interface (PAC-US444CN-1) □□ Hand-held Wireless Remote Controller (PAR-FL32MA; req.PAR-FA32MA-E) □□ Wireless Signal Receiver Module PAR-FA32MA (for PAR-FL32MA-E) (For data on specific indoor units [all ducted, all non-ducted, and both ducted and non-ducted] combinations, see the MXZ Technical and Service Manual.) Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. Electrical Requirements Power Supply . . . . . . . . . . . . . . . . . . . 208 / 230V, 1-Phase, 60 Hz MCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 A Voltage Indoor - Outdoor S1-S2 . . . . . . . . . . . . . . . . . . . . . . . AC 208 / 230V Indoor - Outdoor S2-S3 . . . . . . . . . . . . . . . . . . . . . . . . . . . DC ±24V Fan Motor (ECM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.23 F.L.A. Airflow (Lo - Med - Hi) . . . . . . . . . . . . . . . . . . 280 - 320 - 350 Dry CFM 250 - 290 - 320 Wet CFM Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . Polypropylene Honeycomb Sound Pressure Level (Lo - Med - Hi) . . . . . . . . . 29 - 32 - 38 dB(A) DIMENSIONS W D H UNIT INCHES / MM 22-7/16 / 570 22-7/16 / 570 9-1/4 / 235 GRILLE INCHES / MM 25-5/8 / 650 25-5/8 / 650 13/16 / 20 Weight (Unit/Grille) Lbs.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 / 7 kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16.5 / 3 External Finish (Unit/Grille) . . . . . . . . . . Galvanized-steel Sheets / Munsell 6.4Y 8.9 / 0.4 Field Drainpipe Size O.D. . . . . . . . . . . . . . . . . . . . . . 1-1/4” / 32 mm Refrigerant Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R410A Refrigerant Pipe Size O.D. Gas Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/8" / 9.52 mm Liquid Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4" / 6.35 mm Connection Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flared Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. DIMENSIONS: SLZ-KA09NA Detail drawing of fresh air intake Ceiling hole Fresh air intake 12 1-7/32(31) 3-7/16(87) 2-7/32(56) Grille Ceiling surface 1-1/16 Terminal block +3/16 (27 +5) 0 0 25/32(20) 7-19/32(193) Refrigerant pipe (liquid) Wiring entry 7-5/32(182) Drain pipe VP-25 connection (O.D. 1-1/4( 32)) Suspension bolt M10 or W3/8 9-1/16(230) 1-7/8(48) 7-15/16(202) 8-3/16(208) Refrigerant 21/32(17) pipe (gas) 19/32~1-15/32(15~37) 22-11/16~24-13/32(576~620) Ceiling hole 9-1/4(235) 2-1/14(57) Ceiling surface 7-27/32(199) 13-27/32(352) 13-3/16(335) 1-1/2~2-9/32(38~58) Suspension bolt lower edge 2-19/32(66) 2-7/8( 73.4) Cut out hole 0 22-7/16(570) 3-21/32(93) 25-19/32(650) 11-27/32(301) Air outlet hole 1-3/8(35) 4-3/4(121) 22-7/16(570) 13-3/16(335) 22-11/16~24-13/32(576~620) 16-17/32(420) Suspension bolt pitch Suspension bolt pitch 19/32~1-15/32(15~37) Refrigerent pipe (liquid) Refrigerent pipe (gas) SLZ-KA09NA 1/4 inch ( 6.35mm) flared connection 3/8 inch ( 9.52mm) flared connection SLZ-KA12NA 1/4 inch ( 6.35mm) flared connection 3/8 inch ( 9.52mm) flared connection SLZ-KA15NA 1/4 inch ( 6.35mm) flared connection 1/2 inch ( 12.7mm) flared connection Models Brand label 2-5/32(55) Grille V/M Drain hole V/M Auto vane 14-27/32(377) Air intake hole 11-27/32(301) Air outlet hole 25-19/32(650) 1(25) 3- 1/8( 2.8) Burring hole 20-7/8(530) 120 19/32~1-15/32(15~37) 3-15/16( 100) 4-21/32(118) 19/32~1-15/32(15~37) Unit : inch (mm) V/M V/M Air intake grille Vane motor 14-27/32(377) Air intake hole 1-3/8(35) 2-5/32(55) 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com FORM# SLZ-KA09NA for MXZ MULTI-ZONE SYSTEMS - 201604 Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc.