Fire Alarm Systems | SM 210 LSN RW Single Action Call Points SM 210 LSN RW Single Action Call Points ▶ Alarm triggering by breaking of the glass pane ▶ Protection against injury with foil-labeled pane ▶ Indicator LED for triggered alarm or for inspection evaluation ▶ Individual call point identification ▶ Call point query routines with evaluation and multiple transmission. The SM 210 LSN RW Single Action Call Point is used for setting off an alarm by hand in the LSN. System Overview 1 They are suitable for use throughout Europe (except Germany). j4 j4 B A j4 2 Pos. Description 1 Call points for interior areas (IP 54) 2 Call points for exterior areas (IP 67) with sealed surface-mounted housing A For installation on a flush-mounted box, with cover frame B Surface-mounted housing www.boschsecurity.com 2 | SM 210 LSN RW Single Action Call Points • Functions An installation height of 1400 mm ±200 mm, measured from the middle of the call point to the floor, must be maintained. Manual call points must be adequately illuminated by sunlight or another light source (including emergency lighting if present). The maximum number of LSN elements that may be connected depends on their current consumption from the LSN data line. The limit values should be taken from the product information supplied with the fire panel used. Standards, guidelines and planning recommendations regarding the installation location etc. should also be taken into consideration. The regulations of the local fire services must be observed. • • 2 1 • • 5 Parts Included 3 Type of device Qty. Components SM 210 LSN RW, 1 red, for surface 1 mounting in indoor 1 areas Single Action Call Point, red housing Surface-mounted housing, color red Key After the glass pane (1) is broken, the alarm is triggered by the call point of the microswitch (2) jumping forward and the indicator LED (3) blinks. SM 210 LSN RW, 1 red, for surface 1 mounting in indoor 1 areas Single Action Call Point, red housing Cover frame, red Key To reset the microswitch (2), replace the glass plate (1). The indicator LED (3) goes out. SM 210 LSN RW, 1 blue, for surface 1 mounting in indoor 1 areas Single Action Call Point, blue housing Surface-mounted housing, color blue Key SM 210 LSN RW, 1 blue, for surface 1 mounting in indoor 1 areas Single Action Call Point, blue housing Cover frame, blue Key SM 210 LSN RW, 1 red, for surface 1 mounting in outdoor 1 areas Single Action Call Point, red housing Surface-mounted housing, IP 67, color red Key 4 This does not reset the alarm on the fire panel. Individual call point identification with display of the call point address on the fire panel ensures the quick location of the triggered call point. Call point test (test alarm): In an alarm test, the button key is pushed upwards into the cut-out (4). This releases the catch (5) on the plate (1): the plate shifts downwards and the microswitch is triggered (2). Variants The designs of the Single Action Call Points for interior and exterior areas are identical. Three installation variants are available: Technical Specifications • • • Operating voltage 10 V DC . . . 33 V DC Current consumption 0.4 mA SM 210 LSN RW, for indoor surface mounting SM 210 LSN RW, for indoor flush mounting SM 210 LSN RW, for outdoor surface mounting The call points for interior areas are available in red and blue; the call points for exterior areas are available in red. Installation/Configuration Notes • Manual call points must be mounted visibly along escape and rescue routes (e. g. exits, passageways, stairwells) and be easily accessible. Electrical Mechanics Dimensions (H x W x D) • • • Indoor area surface mounting 87 x 87 x 53 mm Indoor area flush mounting 107 x 107 x 20 (36) mm Outdoor area surface mounting 111 x 111 x 65 mm Housing material Plastic, ABS SM 210 LSN RW Single Action Call Points | 3 • • Colors Weight Red, RAL 3001 Blue, RAL 5005 Approx. 400 g Environmental Considerations Protection class as per EN 60529 • • Detector for indoor areas IP 54 Detector for outdoor areas IP 67 Permissible operating temperature -25 °C . . . +65 °C Ordering Information SM 210 LSN RW, Red, for Surface Mounting in Indoor Areas with surface-mounted housing SM210-S-red SM 210 LSN RW, Red, for Flush Mounting in Indoor Areas with masking frame for larger wall cuts SM210-R-red SM 210 LSN RW, Blue, for Surface Mounting in Indoor Areas with surface-mounted housing SM210-S-blue SM 210 LSN RW, Blue, for Flush Mounting in Indoor Areas with masking frame for larger wall cuts SM210-R-blue SM 210 LSN RW, Red, for Surface Mounting in Outdoor Areas with surface-mounted housing SM210-S-red-outd Accessories Spare Glass Panes for Single Action Call Points SM 210 LSN RW/ SM 120 RW, PU = 10 units SM210-SPAREGLASS www.boschsecurity.com 4 | SM 210 LSN RW Single Action Call Points Americas: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 [email protected] www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 [email protected] www.boschsecurity.com © Bosch Security Systems Inc. 2009 | Data subject to change without notice T285376651 | Cur: en-US, V10, 12 Feb 2009 Asia-Pacific: Represented by Robert Bosch (SEA) Pte Ltd, Security Systems 38C Jalan Pemimpin Singapore 577180 Phone: +65 6319 3453 Fax: +65 6319 3499 [email protected] www.boschsecurity.com