Small unvented water heating Multipoint | Hotflo
95 900 821 Issue 8
04 Features and benefits
Multipoint 10/15
FOR UP TO THREE BASINS
Multipoint is the market-leading range of small unvented water heaters and is ideal for any situation where a single heater is required to service the needs of multiple outlets. Multipoint is supplied with a factory-fitted temperature and pressure relief valve, is quick and easy to install and is offered in a wide range of capacities and ratings. High-grade copper is used for the Multipoint inner container because of its optimum performance in terms of durability and corrosion resistance. Copper requires no sacrificial anode and therefore avoids the need for regular inspection and replacement. Unlike other lesser grade materials, it also withstands shock and vibration during delivery, installation and maintenance. 10 and 15 litre capacities Choice of 3kW and 4.5kW ratings Five-year inner container guarantee Replaceable long-life alloy-sheathed element Externally adjustable thermostat 10°C to 70°C max. - lockable in hot or mid-range position CFC/HCFC free (ODP zero) flame-retardant expanded polystyrene Element ‘On’ indicator No anode to inspect or replace Suitable for use with any standard mixer or tap Fitted with 1 metre of 3-core cable Comprehensive installation instructions BEAB and kiwa approved to UK water supply regulations IPX4 Rated Multipoint 10/15 selection matrix Capacity
10 15
Up to 2 basins
Up to 3 basins
■ ■
Rating 3kW 4.5kW
■ ■
■ ■
N.B. Figures are for guidance only, the Heatrae Sadia Specifier Advice team should be contacted to discuss requirements for specific sites.
Accessories supplied with all units Factory-fitted temperature and pressure relief valve Easy-fit wall-mounting bracket Discharge funnel (tundish) Service valve Optional accessories: See pages 06 and 07
08 Features and benefits
Multipoint 30/50
FOR UP TO SEVEN BASINS
Multipoint 30/50 are ideal for commercial applications such as cloakrooms, kitchens or washrooms, where a single heater is required to service multiple draw-offs. The 50 litre product may also be used for single point showering. Versions of both products are available with 1kW elements for use in locations where electrical loading is restricted (horizontal unit 3kW only). Multipoint 30 and 50 units are supplied complete with necessary installation accessories. A thermostatic blending valve can also be used. See page 06 for details. As with all unvented units above 15 litres, it is a Building Regulation requirement that installers are competent to install Multipoint 30 & 50 litre units. This normally means having successfully completed a course in unvented systems. For details on training courses call 0845 600 7402 or 01362 853091. 30 and 50 litre capacities Choice of
1kW†
BEAB and kiwa approved to UK water supply regulations
and 3kW ratings
Accessories supplied with all units Easy-fit wall-mounting brackets Discharge funnel (tundish) Combined pressure reducing valve with built-in strainer Expansion vessel and fixing bracket(s) Pressure relief (expansion) valve
Five-year inner container guarantee Factory-fitted temperature and pressure relief valve Heavy gauge copper inner container
Optional accessories TMV2 and TMV3 thermostatic blending valves (see page 06)
Replaceable long-life alloy-sheathed element Externally adjustable thermostat 5°C to 75°C max. – lockable in hot or mid-range position CFC/HCFC free (ODP zero) insulation Element ‘On’ indicator No anode to inspect or replace Suitable for use with any standard mixer or tap Fitted with 1 metre of 3-core cable Comprehensive installation instructions Multipoint 30/50 selection matrix Capacity
30 50 30 Horizontal 50 Horizontal
Up to 5 basins low usage
Up to 7 basins low usage
■
Up to 3 basins heavy usage
Up to 5 basins heavy usage
1 commercial sink
■ ■
■
1 basin / 1 shower* low usage
■
■
■
■
■ ■
■ ■
2 commercial sinks
■ ■
N.B. Figures are for guidance only, the Heatrae Sadia Specifier Advice team should be contacted to discuss requirements for specific sites.
† Vertical models only. *Based on a five-minute shower @ 12 ltr/min., 40°C capacity, recommendations are based on BS 6700.
Rating 1kW 3kW
■ ■
■ ■ ■ ■
10 Features and benefits
Hotflo
FOR UP TO THREE BASINS
The Hotflo range sets a new standard in value for money, small unvented water heating. It features an inner container with integral element for increased reliability and quick, easy replacement. Hotflo is suitable for a wide variety of point-of-use applications and a full range of accessories is available to ensure Hotflo can be installed in any situation. High-grade copper is used for the Hotflo inner container because of its optimum performance in terms of durability and corrosion resistance. Copper requires no sacrificial anode and therefore avoids the need for regular inspection and replacement. Unlike other lesser grade materials it also withstands shock and vibration during delivery, installation and maintenance. 10 and 15 litre capacities 2.2kW element rating Replaceable copper inner container with integral heating element Two-year guarantee Externally-adjustable thermostat 10°C to 70°C CFC/HCFC free (ODP zero) flame-retardant expanded polystyrene. Element ‘On’ indicator No anode to inspect or replace Suitable for use with any standard tap or mixer Fitted with 1 metre of 3-core cable Comprehensive installation instructions BEAB and kiwa approved to UK water supply regulations Heat exchanger replacement Hotflo’s innovative design makes replacement of the inner container with integral element, quick and easy. The screwless construction of this range allows swift removal of the terminal cover, plug-in thermostat, neon assembly and mains cable. This permits the plastic top moulding to be detached from the steel outer case along with the pre-formed polystyrene insulation. The inner container can now be lifted clear and replaced. Hotflo selection matrix Capacity (litres)
10 15
Up to 2 basins
Up to 3 basins
Rating 2.2kW
■
■ ■
■
N.B. Figures are for guidance only, the Heatrae Sadia Specifier Advice team should be contacted to discuss requirements for specific sites. Capacity recommendations are based on BS 6700.
Accessories supplied with all units Pressure relief valve Optional accessories: See pages 12 and 13
14 Diagrams | Dimensions | Specification | Installation | Guarantee
Multipoint
Specification
FRONT 267 12.5 100
330 min.
Installation
D
B
Multipoint 30/50 must be installed by a competent person in accordance with local Regulations. England and Wales - Building Regulations G3, Scotland - Technical Standards P3, N. Ireland - Building Regulations P5.
Fixing centre of lower location point
B A
Approvals BEAB and kiwa approved to UK water supply regulations. Manufactured in the UK in a BS EN ISO 9001:2000 registered factory.
267 62.5 50
IPX4 Rated.
Installation Mechanical Must be mounted in the vertical position with inlet/outlet at the top. Floor or wall mounted (three screws/ keyhole slots).
Approvals BEAB and kiwa approved to UK water supply regulations. Manufactured in the UK in a BS EN ISO 9001:2000 registered factory.
Plumbing 15mm copper tail ends. Minimum water pressure 0.8 bar (12 psi). For pressures above 4.1 bar (60 psi), Packs U1 and U5 must be used. NB: The pressure relief valve supplied must always be fitted. See accessory installation selection guide on page 13.
TOP
Temperature and pressure relief valve Optional Pack U6 – See accessory selection guide on page 13.
Dimensions Model
Hotflo 10 Hotflo 15
Capacity litre
Rating @240V kW
A mm
B mm
C mm
10 15
2.2 2.2
457 613
500 656
360 516
Weight empty full kg kg
6.5 8.4
16.5 23.4
Fixing Multipoint 10/15 Must be mounted in the vertical position with inlet/outlet at the top. Floor or wall mounted (three screws/easy-fit wall bracket). 74 352
FRONT 25
370
300 min.
121 C
Anode Not required. SIDE
Anode Not required.
Fixing centres of mounting bracket
236
Safety features Pressure Relief Valve set to open at 6 bar. Resettable over-temperature cut-out.
Safety features Multipoint 10/15 Factory-fitted temperature and pressure relief valve opens at 7 bar (100 psi) or 90°C. Resettable over-temperature cut-out. Multipoint 30/50 Manually re-settable thermal cut-out. Factory-fitted temperature and pressure relief valve set to operate at 7 bar and 90°C.
TOP
Fixing centres of mounting bracket
Water container/integral heat unit Replaceable heavy gauge copper inner container, designed for 6 bar working pressure and type tested to 20 bar (290 psi), with embedded rod-type element sheathed in corrosion resistant alloy. Thermostat Rod-type externally adjustable from 10°C to 70°C.
FRONT
Thermostat Multipoint 10/15 Rod-type externally adjustable from 10°C to 70°C, lockable in hot or mid-range position. Multipoint 30/50 Capillary thermostat, externally adjustable from 5°C to 75°C.
168
Thermal insulation CFC/HCFC free (ODP zero) flame-retardant expanded polystyrene.
190
Heat unit Replaceable, alloy sheathed rod-type element.
Multipoint 30/50 (Vertical)
Outer casing White plastic top moulding with steel base and centre section, finished in white stove-enamel.
Fixing centres of wall screws (unit hangs on keyhole slots)
Water container Multipoint 10/15 Replaceable heavy gauge copper inner container, designed for 6 bar (87psi) working pressure and type tested to 20 bar (290 psi). Multipoint 30/50 Heavy gauge copper. Type tested to 20 bar (290 psi)
SIDE
Rating Hotflo 10 and 15 2.2kW @ 240V, (2.0kW @ 230V) 59
C
D
A
C
B
Thermal insulation Multipoint 10/15 CFC/HCFC free (ODP zero) flame-retardant expanded polystyrene. Multipoint 30/50 CFC/HCFC free (ODP zero) flame-retardant expanded polyurethane.
Capacities 10 and 15 litre.
252 171
Outer casing Multipoint 10/15 White plastic top moulding with steel base and centre section, finished in white stove-enamel. Multipoint 30/50 White plastic top and base mouldings with steel centre section finished in white stove enamel.
Fixing centres of mounting bracket
A
Specification
Rating Multipoint 10/15 3.0kW, 4.5kW @ 240V, (2.8kW, 4.1kW @ 230V), Multipoint 30/50 1.0kW†, 3.0kW @ 240V, 0.9kW†, 2.8kW @ 230V.
59
190
Hotflo
Capacities 10, 15, 30 and 50 litre.
252 171
Multipoint 10/15
Diagram | Dimensions | Specification | Installation | Guarantee | Ordering guide 15
Fixing Multipoint 30/50 vertical units Must be mounted in the vertical position with inlet/outlet at the bottom. Temperature and pressure relief valve fitted to the top of the heater. Wall-mounted by easy-fit wall bracket and spacers (supplied).
SIDE
100
330 min.
• It has been installed in accordance with the instructions contained in the installation manual and all relevant Codes of Practice and Regulations in force at the time of installation.
250 min.
20
Fixing centres of mounting brackets
300 min. vertical pipe drop from tundish
390
Optional thermostatic blending valve Accessory Pack U3 and Pack U7 (see page 06) allows water to be stored at high temperature and blended with cold to a preset outlet temperature. Electrical The unit must be permanently connected to the electrical supply through a double-pole linked switch with minimum breaking capacity suitable for the loading. Must conform to current IEE wiring regulations. Accessories (Supplied with all units) Tundish and Service valve.
Fixing centres of mounting brackets B
Guarantee for Multipoint Multipoint is guaranteed for a period of five years and its immersion heater and thermal control for a period of two years from the date of purchase against faulty manufacture and materials provided that:
FRONT
Dimensions
Multipoint 10 Multipoint 10 Multipoint 15 Multipoint 15 Multipoint 30V Multipoint 30V Multipoint 50V Multipoint 50V Multipoint 30H Multipoint 50H
Capacity Rating litre @240V kW
A mm
B mm
C mm
D mm
Weight empty full kg kg
10 10 15
3 4.5 3
457 572 500 350 457 572 500 350 613 728 656 506
15 30 30
4.5 1 3
613 728 656 506 8.8 23.8 616 665 788 506 12.5 42.5 616 665 788 506 12.5 42.5
50 50 30 50
1 3 3 3
888 888 470 742
937 937 665 937
• The unit has not been tampered with and has been regularly maintained as detailed in the fitting instructions. • It has been used only for heating potable water. Evidence of purchase and date of supply must be submitted. This guarantee does not affect your statutory rights. The unit is not guaranteed against damage by frost or due to excessive scaling.
Safety valve discharge Multipoint 10/15 The temperature and pressure relief valve must be plumbed to discharge in a safe visible location. Multipoint 30/50 Temperature and pressure relief valve and expansion valve must be plumbed to discharge in a safe visible location in accordance with the local regulations stated above (Tundish supplied).
C
Model
• Any valves or controls are of Heatrae Sadia recommended type.
Connections Heater 15mm copper tube tails. Tundish: Inlet - 1/2” BSP male Outlet - 3/4” BSP female. Service Valve - 15mm compression.
A 115
6.9 6.9 8.8
16.9 16.9 23.8
1060 777 19.3 69.3 1060 777 19.3 69.3 788 12.5 42.5 1060 19.3 69.3
• It has been installed in accordance with the instructions contained in the installation manual and all relevant Codes of Practice and Regulations in force at the time of installation. • Any valves or controls are of the recommended type. • The unit has not been tampered with and has been regularly maintained as detailed in the fitting instructions. • It has been used only for heating potable water. • Within 60 days of installation the user completes and returns the certificate supplied along with proof of purchase to register the product. The unit is not guaranteed against damage by frost. The Multipoint immersion heater and thermal controls are guaranteed for a period of two years, from the date of purchase, with the exception of damage due to excessive scaling. Evidence of purchase and date of supply must be submitted. The guarantee will not be transferable. This guarantee does not affect your statutory rights. † Vertical models only.
Electrical The unit must be permanently connected to the electrical supply through a double-pole linked switch with minimum breaking capacity of 13 Amps. Must conform to current IEE wiring regulations.
The Hotflo is guaranteed for a period of two years from the date of purchase, against faulty manufacture and materials provided that:
Plumbing Minimum water pressure 0.8 bar (12 psi). Multipoint 10/15 pressures above 4.1 bar (60 psi), Packs U1 and U2 must be used. Multipoint 30/50 accessories supplied with all units.
Multipoint 30/50 (Horizontal)
Optional thermostatic blending valve Accessory Pack U3 and Pack U7 (see page 06) allows water to be stored at high temperature and blended with cold to a preset outlet temperature.
Guarantee for Hotflo
Fixing Multipoint 30/50 horizontal units Must be mounted in the horizontal position with the inlet and outlet to the right of the heater. Temperature and pressure relief valve fitted to the left of the heater. Wall-mounted using brackets (supplied).
BOTTOM
Safety valve discharge The pressure relief (expansion) valve or temperature & pressure relief valve (if used) must be plumbed to discharge in a safe visible location.
Ordering guide Rating @ 240V kW
Model
Multipoint Multipoint Multipoint Multipoint Multipoint Multipoint Multipoint Multipoint Multipoint Multipoint
Accessories ordering guide
10 10 15 15 30V 30V 50V 50V 30H 50H
Product code
3 4.5
95:050:143 95:050:145
3 4.5 1
95:050:144 95:050:146 95:050:152
3 1 3
95:050:150 95:050:153 95:050:151
3 3
95:050:154 95:050:157
Model
Accessory pack U1 Accessory pack U2 Accessory pack U3 Accessory pack U5 Accessory pack U6 Accessory pack U7
Product code
See pages 06 and 12 for details 95:970:352 95:970:351 See page 06 for details See pages 06 and 12 for details 95:970:354 See page 12 for details 95:970:356 95:970:359 See page 12 for details See pages 06 and 12 for details 95:970:360
Supplied complete with external expansion vessel, combined pressure reducing valve and strainer, check valve, expansion valve, tundish and wall brackets.
95:050:148
2.2 Hotflo 10 Hotflo 15 2.2 Replacement inner container with integral element 2.2 10 litre
95:608:916
15 litre
95:608:917
2.2
95:050:149
Specification Advice Tel 01603 420220 Fax 01603 420229 E-mail