Preview only show first 10 pages with watermark. For full document please download

Smc_nvfs3100_3fz

   EMBED


Share

Transcript

2.66 S O L E N O I D V A LV E S S E R I E S NVFS S E R I E S NVFS 2000, 3000, 4000, 5000, 6000 5 P O R T P I L O T O P E R AT E D B A S E -M O U N T E D / P L U G -I N T Y P E Large Flow Capacity Low Power Consumption Long Life Ease Maintenance M a n y Va r i a t i o n s Av a i l a b l e For further information, consult SMC Customer Service M O D E L NVFS2000 Position S Number Of Type Port Size Cv Response Solenoid Plug-In (NPTF) Factor Time (ms) Single NVFS2100 1/8 0.7 15 or less 1/4 0.83 2 Position Double Closed NVFS2200 NVFS2300 Center Exhaust 3 Position NVFS2400 Center Pressure NVFS2500 Center Perfect NVFS2600 (Double Check) 1/8 0.7 1/4 0.83 1/8 0.65 1/4 0.67 1/8 0.65 1/4 0.67 1/8 0.65 1/4 0.67 1/8 0.4 1/4 0.4 13 or less 20 or less 20 or less 20 or less 25 or less TECHNICAL SPECIFICATIONS OPTIONAL TECHNICAL SPECIFICATIONS STANDARD Fluid Air and Inert Gas Max Operating Pressure Valve Y M B O L S 150 PSI (1MPa) Min Operating 2 Position 15 PSI (0.1MPa) Pressure 3 Position 22 PSI (0.15MPa) Ambient & Fluid Temperature Lubrication Pilot Operator Manual Override Protection Construction Electrical Rated Voltage AC DC Allowable Voltage Range Coil Insulation AC Lock Type (Tool), Lock Type (Lever) DC 100V50/60Hz, 200V50/60Hz 6V, 48V, 100V Bottom Ported Subplate Non Locking Push Type (Flush) Option W/Indicator Light & Surge Dust Proof 110VAC50/60Hz, 220V50/60Hz, 24V50/60Hz 12V, 24V -15 ~ 10% Rated Voltage (Power Consumption) Holding 2.3VA(1.5W)/60Hz, 3.4VA(2.1W)/50Hz FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT, REQUEST CATALOG REFERENCE N233 Voltage Porting Class B or Equivalent Plug In Pilot Operator Non Locking Push Type (Extended), Not Required 5.0VA/60Hz, 5.6VA/50Hz Electrical Entry External Pilot Type Manual Override 14~140ºF (-10~60ºC) Apparent Power AC InRush Power Consumption DC Pilot Type 1.8W Conduit Terminal (Base Access) Voltage Suppressor S O L E N O I D V A LV E S S E R I E S NVFS 2.67 HOW TO O R D E R NVFS2000 NVFS 2 00 F PORT SIZE - ……Without Subplate 01T …1/8 NPTF 02T …1/4 NPTF * Bottom Ported 1/8 NPTF Only POSITION 1 2 3 4 5 6 ……2 ……2 ……3 ……3 ……3 ……3 Position Position Position Position Position Position Single Double Closed Center Exhaust Center P re s s u re C e n t e r Perfect PORTING - ……Side *B …Bottom Note) *1/8 NPTF Only BODY TYPE 0 … … P l u g - I n Ty p e MANUAL OVERRIDE - … … N o n L o c k i n g P u s h Ty p e ( F l u s h ) * A … N o n L o c k i n g P u s h Ty p e ( E x t e n d e d ) B … … L o c k Ty p e ( S c re w Ty p e ) * C … L o c k Ty p e ( L e v e r ) P I L O T O P E R AT O R - ……Internal R … … E x t e r n a l ( S p e c i a l O rd e r ) V O LTA G E 1 2 3 4 5 6 9 N o t e ) * S p e c i a l O rd e r … … 1 0 0 VA C ( S p e c i a l O rd e r ) … … 2 0 0 VA C ( S p e c i a l O rd e r ) … … 1 1 0 VA C … … 2 2 0 VA c ……24VDC ……12VDC … … O t h e r s ( S p e c i a l O rd e r ) ELECTRICAL ENTRY F … … T h ro u g h B a s e OPTIONS - ……None Z ……With Indicator Light and S u r g e Vo l t a g e S u p p re s s o r HOW TO O R D E R MANIFOLD SEE INSIDE FRONT COVER FOR DETAILS OF YOUR LOCAL SALES OFFICE FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT, REQUEST CATALOG REFERENCE N233 2.68 S O L E N O I D V A LV E S S E R I E S NVFS HOW TO O R D E R MANIFOLD / OPTION PARTS FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT, REQUEST CATALOG REFERENCE N233 A S S E M B LY