S E R I E S NVFS 2000, 3000, 4000, 5000, 6000 5 P O R T P I L O T O P E R AT E D B A S E -M O U N T E D / P L U G -I N T Y P E Large Flow Capacity Low Power Consumption Long Life Ease Maintenance M a n y Va r i a t i o n s Av a i l a b l e For further information, consult SMC Customer Service
M O D E L NVFS2000 Position
S Number Of
Type
Port Size
Cv
Response
Solenoid
Plug-In
(NPTF)
Factor
Time (ms)
Single
NVFS2100
1/8
0.7
15 or less
1/4
0.83
2 Position Double Closed
NVFS2200 NVFS2300
Center Exhaust 3 Position
NVFS2400
Center Pressure
NVFS2500
Center Perfect
NVFS2600
(Double Check)
1/8
0.7
1/4
0.83
1/8
0.65
1/4
0.67
1/8
0.65
1/4
0.67
1/8
0.65
1/4
0.67
1/8
0.4
1/4
0.4
13 or less 20 or less 20 or less 20 or less 25 or less
TECHNICAL SPECIFICATIONS OPTIONAL
TECHNICAL SPECIFICATIONS STANDARD Fluid
Air and Inert Gas
Max Operating Pressure
Valve
Y M B O L S
150 PSI (1MPa)
Min Operating
2 Position
15 PSI (0.1MPa)
Pressure
3 Position
22 PSI (0.15MPa)
Ambient & Fluid Temperature Lubrication Pilot Operator Manual Override Protection Construction
Electrical Rated Voltage
AC DC
Allowable Voltage Range Coil Insulation
AC
Lock Type (Tool), Lock Type (Lever) DC
100V50/60Hz, 200V50/60Hz 6V, 48V, 100V Bottom Ported Subplate
Non Locking Push Type (Flush)
Option
W/Indicator Light & Surge
Dust Proof 110VAC50/60Hz, 220V50/60Hz, 24V50/60Hz 12V, 24V -15 ~ 10% Rated Voltage
(Power Consumption) Holding
2.3VA(1.5W)/60Hz, 3.4VA(2.1W)/50Hz
FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT, REQUEST CATALOG REFERENCE N233
Voltage Porting
Class B or Equivalent
Plug In
Pilot Operator Non Locking Push Type (Extended),
Not Required
5.0VA/60Hz, 5.6VA/50Hz
Electrical Entry
External Pilot Type
Manual Override
14~140ºF (-10~60ºC)
Apparent Power AC InRush Power Consumption DC
Pilot Type
1.8W Conduit Terminal (Base Access)
Voltage Suppressor
S O L E N O I D V A LV E S S E R I E S NVFS
2.67
HOW TO O R D E R NVFS2000
NVFS 2
00
F PORT SIZE - ……Without Subplate 01T …1/8 NPTF 02T …1/4 NPTF * Bottom Ported 1/8 NPTF Only
POSITION 1 2 3 4 5 6
……2 ……2 ……3 ……3 ……3 ……3
Position Position Position Position Position Position
Single Double Closed Center Exhaust Center P re s s u re C e n t e r Perfect
PORTING - ……Side *B …Bottom Note) *1/8 NPTF Only
BODY TYPE 0 … … P l u g - I n Ty p e
MANUAL OVERRIDE - … … N o n L o c k i n g P u s h Ty p e ( F l u s h ) * A … N o n L o c k i n g P u s h Ty p e ( E x t e n d e d ) B … … L o c k Ty p e ( S c re w Ty p e ) * C … L o c k Ty p e ( L e v e r )
P I L O T O P E R AT O R - ……Internal R … … E x t e r n a l ( S p e c i a l O rd e r ) V O LTA G E 1 2 3 4 5 6 9
N o t e ) * S p e c i a l O rd e r
… … 1 0 0 VA C ( S p e c i a l O rd e r ) … … 2 0 0 VA C ( S p e c i a l O rd e r ) … … 1 1 0 VA C … … 2 2 0 VA c ……24VDC ……12VDC … … O t h e r s ( S p e c i a l O rd e r )
ELECTRICAL ENTRY F … … T h ro u g h B a s e
OPTIONS - ……None Z ……With Indicator Light and S u r g e Vo l t a g e S u p p re s s o r
HOW TO O R D E R MANIFOLD
SEE
INSIDE
FRONT
COVER
FOR
DETAILS OF YOUR LOCAL SALES OFFICE
FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT, REQUEST CATALOG REFERENCE N233
2.68
S O L E N O I D V A LV E S S E R I E S NVFS
HOW TO O R D E R MANIFOLD / OPTION PARTS
FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT, REQUEST CATALOG REFERENCE N233
A S S E M B LY