Instruction Sheet
SMPM Jack
408-10180
(Direct Solder Attachment) Connector 1757642-1
15 FEB 08
Rev A
2. Place a saw in the saw slot and while rotating the cable, cut through the cable jacket and into, but not through, the dielectric. Remove the cable from the cable fixture subassembly, and finish cutting the dielectric with a blade.
Connector Assembly
3. Pry the jacket and dielectric from the cable to expose the center conductor. Make sure that the center conductor meets the dimension shown in Figure 3. Figure 1
Cable Jacket 0.50 +0.13 [.020 +.005]
1. INTRODUCTION
SMPM Jack (Direct Solder Attachment) Connector 1757642–1 shown in Figure 1 is designed to be soldered to semi–rigid coaxial cable with a diameter of 1.20 mm [.047 in.] using the tools referenced in Figure 2.
DESCRIPTION
Cable Fixture Subassembly Insert Assembly
CURRENT
1055439-1
° °
90
Cable Fixture
Cable Center
Cable
Conductor
Dielectric
Subassembly Note: Not to Scale
2098-5206-54 (T-4567)
1055543-1
2098-5797-54
1055887-1
2598-5406-02
Subassembly)
Figure 2 Dimensions in this instruction sheet are in millimeters [with inches in brackets]. Figures and
i
_
90
60
PREVIOUS
Locator Tool (For Housing
1.78 +0.25 [.070 +0.10]
TOOL PART NUMBER
TOOL
NOTE
Hole Pattern 2
illustrations are for reference only and are not drawn to scale.
2. DESCRIPTION
The jack consists of a one–piece connector assembly. See Figure 1.
Figure 3
4. Insert the cable into the housing subassembly until it bottoms. 5. Place the assembly in the cable fixture subassembly as shown in Figure 4. Tighten the clamp screw to secure the cable, and tighten the locator tool to seat the housing subassembly firmly against the cable. 6. Using solder made of 60% tin and 40% lead, join the housing subassembly to the cable at the location shown in Figure 4. 7. Adherence to assembly procedure should yield tolerances shown in Figure 5. 4. REPLACEMENT AND REPAIR
3. ASSEMBLY PROCEDURE DANGER
CAUTION
Replace any defective or damaged components.
Follow safety precautions included with the tools
!
used for assembly.
1. Insert the squared cable end into Hole Pattern 2 of the cable fixture subassembly. Refer to Figure 3.
E
2008 Tyco Electronics Corporation, Harrisburg, PA
All International Rights Reserved
Components of the jack are not repairable.
5. REVISION SUMMARY
S Initial release of document
TOOLING ASSISTANCE CENTER 1-800-722-1111
This controlled document is subject to change.
PRODUCT INFORMATION 1-800-522-6752
For latest revision and Regional Customer Service,
TE logo and Tyco Electronics are trademarks. *Trademark. Other products, logos, and company names used are the property of their respective owners.
visit our website at www.tycoelectronics.com
1 of 2 LOC B
408-10180
SMPM Jack (Direct Solder Attachment) Connector 1757642-1
Clamp Screw Cable Fixture Subassembly
Solder Here
0.00/-0.20 [.000/-.008] Contact Locator Tool Cable
(For Housing Subassembly)
Insert Assembly
Figure 5
Figure 4
2 of 2
Reference Plane
Tyco Electronics Corporation
Rev A