Preview only show first 10 pages with watermark. For full document please download

Solenoid Valves Selection Guide Ul Listed Valves H010 / 040

   EMBED


Share

Transcript

SOLENOID VALVES Selection Guide UL Listed Valves H010 / 040 401 / 402 H030 3E1 Mini-Mizer H110 31E1 / 41E1 Mini-Myte 125E1LW 310 / 410 315 / 415 H180 062 125 Tyna-Mite 42 TAC3 H240 320 / 420 500 / 501 / 590 AIR PILOTED VALVES H110 125 H180 250 42 TAC3 500 / 501 / 590 Super Quick Exhaust 125 / 250 / 500 / 590 Vacuum Cartridge Insert Valves Glue Valves TAC / TAC2 / TAC3 VALVES Introduction Operation Circuits Model Descriptions Valves Operators ACCESSORIES 8/1/97 Selectio 3 8/1/97 Selectio 4 8/1/97 Guidelin 1 8/1/97 ULRecogn 2 position 4/15/98 H010dainl 7 4/15/98 H010dainl 8 4/15/98 H010dainl 9 4/15/98 H010dainl 10 20 (0.8) 10 (0.4) mm (in) 2 places ø mounting hole 2 (0.08) ø counterbore 3 (0.13) depth 1 (0.04) 34 (1.3) 5 (0.2) P 13 (0.5) 8 (0.3) IN A 7 (0.3) 4/15/98 H010dainl R EXH 6 (0.2) 3 places M3 x 0.5 1 (0.02) 5 2 (0.1) (0.2) 11 8/1/97 H010dam 12 8/1/97 H010dam 13 8/1/97 H041iam 14 8/1/97 H041iam 8/1/97 H041iam 16 8/1/97 H040iam 17 8/1/97 H040iam 18 8/1/97 H041iai 19 8/1/97 H041iai 20 10 (0.4) 55 (2.2) 10 (0.4) 34 (1.3) B Manual override 5 places M3 x 0.5 6 (H040 only) A (0.3) 1 (0.4) 10 (0.4) 4/15/98 H040iainl 300 (12) 2 (0.1) 2 places ¿ through hole 2 (0.08) 7 (0.3) ¿ counterbore 3 (0.13) depth 1 (0.04) mm (in) 20 (0.8) 2 places ¿ through hole 2 (0.08) 6 (0.3) 11(0.4) PR R1 P 14 (0.5) 13 (0.5) R2 7 (0.3) 3 (0.1) 21T 4/15/98 H040iainl 22 (mm) in. H040-4E2 300 (12) 20 (0.8) S2 5 (0.2) A Manual override 5 places M3 x 0.5 (H040 only) 3 (0.1) 20 (0.8) mm (in) 2 places ¿ through hole 2 (0.08) 3 (0.1) 3 (0.1) 5 (0.2) 41 (1.6) R1 6 (0.3) P R2 B 82 (3.2) PR 3 (0.1) PR 6 (0.3) S1 Manual override 2 (0.1) 2 7 (0.1) (0.3) 3 (0.1) 2 places ¿ through hole 2 (0.08) ¿ counterbore 3 (0.13) depth 1 (0.04) 4/15/98 H040iainl 23T 4/15/98 H040iainl 24 8/1/97 H041iai 25 8/1/97 H041iam 26 MANIFOLD DIMENSIONS FOR 2, 3-, AND 4-WAY VALVE COMBINATATIONS A B 4 (0.2) 8 (0.3) 4 (0.2) 6 (0.3) 19(0.8) A A B 11 (0.4) 0.8 (0.03) 24 (1) S2 55 (2.2) A B mm (in) 36 (1.4) 15 (0.6) A 10 (0.4) 8 (0.3) 2 places 1/8 NPT (with one plug) P 13 (0.5) 30 (1.2) R B 16 82 2 places ˘ through (0.6) (3.2) hole 3 (0.13) S1 28 (1.1) 11 (0.4) 2 places 10-32 UNF (with one plug) H040-4E1 H040E1, H040E1-11 H040-4E2 Blockoff plate (-BP) 4/15/98 H040iainl 27 8/1/97 H040iam 28 8/1/97 H041iai 24 4/15/98 H010dainl 30 4/15/98 H010dainl 31 8/1/97 401/402 32 8/1/97 401/402 33 8/1/97 401/402 34 8/1/97 401/402 35 8/1/97 401/402 36 8/1/97 401/402 37 8/1/97 401/402 38 8/1/97 401/402 39 8/1/97 401/402 40 4/15/98 H030 41 4/15/98 H030 42 4/15/98 H030 43 4/15/98 H030 44 4/15/98 H030 45 4/15/98 H030 46 SOLENOID DIMENSION DIAGRAMS 2-, 3-way H(V) 030E1 15 (0.6) (mm) in. 24 (0.9) mm (in) Manual override 48 (1.9) A 11 A (0.4) 2 places ø mounting hole 3 (0.12) ø counterbore 2.8 (0.11) depth 5.4 (0.21) 10-32 UNF 18 (0.3) 11 (0.4) 2 places ø mounting hole M3 x (0.5) 18 (0.7) 14 (0.6) P 10-32 UNF P ø 2 (0.1) R 9 (0.4) 9 (0.4) 15 (0.6) H030-4E1 mm (in) 24 (0.9) Manual override 61 (2.4) A B 24 (1.0) 11 (0.4) 12 (0.5) P A B 8.5 2 places (0.3) ø mounting hole 3 (0.12) ø counterbore 3 (0.11) depth 5 (0.21) 2 places ø mounting hole 3 (0.5) 10-32 UNF R ø 2 (0.1) 8 R1 (0.3) 27 A (1.0) B R2 18 (0.7) 9 (0.4) 4/15/98 H030 13 (0.5) 47 SOLENOID DIMENSION DIAGRAMS (mm) in. ADDITIONAL PARTS (sold separately) Locking protruding type manual override: -83 Mounting base: H030-21 (to top of valve) 6 (.236) C 6.5 (0.3) 1.6 (0.1) 5 (0.2) 2 Places ˘mounting hole 24 4.5(0.2) (0.9) 28 (1.0) 40 (1.6) 10 (0.4) L 36 (1.4) Muffler: KM-06 4(0.2) 34 (1.3) LED indicator L 16(0.6) 6(0.2) 44.5 (1.8) 11.5(0.5) M6 x 1 width 10(0.4) 29 (1.1) (B) 61.5 (2.4) 4/15/98 H030 20.5 (0.8) LED indicator 47B 4/15/98 H030 48 4/15/98 H030 49 4/15/98 H030 50 4/15/98 H030 51 (M3E1) ALL A. C. COILS IN/NO 0.70 (17.9) EXH/NC 2 places #66 terminals 0.11 (2.8) wide X 0.02 (0.4) thick ø 0.47 (11.9) 0.33 EXH (8.3) IN/NO 0.22 (5.5) + 0.44 (11.9) 0.88 (22.2) _ 1.56 (3E1) 1.11 1.94 (3E1) (39.7) (49.2) Override (28.2) 1.91 1.39 (48.4) (35.3) 1.77 0.19 EXH OUT (44.8) (4.7) OUT IN/NO 0.06 (1.6) 3 places10-32 ports 0.53 (13.5) 0.270.27 (6.7) (6.7) 0.11 (2.8) 0.02 (0.4) 0.63 (15.9) 0.31(7.9) 0.66 (16.7) 0.53 (13.5) 0.72 (18.2) 1/21/98 MiniMizr 0.50 (12.7) 2 places 0.20 (5.2) wide slot mount with #8 screws 0.33(8.3) 52 8/1/97 MiniMizer 53 8/1/97 MiniMizer 54 8/1/97 MiniMizer 55 8/1/97 MiniMizer 56 8/1/97 MiniMizer 57 8/1/97 MiniMizer 58 4/15/98 H110inli 59 4/15/98 H110inli 604/15/98 H110inli 60 4/15/98 H110inli 61 4/15/98 H110inli 62 4/15/98 H110inli 63 4/15/98 H110inli 64 4/15/98 H110inli 65 8/1/97 HA110sub 66 SOLENOID VALVE DIMENSION DIAGRAMS (mm) in. H110-4E1 mm (in) 24 (1.0) Manual override Pilot EXH 5 places 10-32 UNF 81 (3.2) R1 18 (0.7) 10 (0.4) 13 (0.5) 17 (0.7) A P B R2 3 (0.1) 6 (0.2) 3 (0.1) 6 (0.2) 2 places ø mounting hole 3 (0.12) ø counterbore 3 (0.11) depth 5 (0.21) 9 (0.4) 9 (0.4) 4.5 (0.2) 17 (0.7) 5 (0.2) 2 places ø mounting hole 3 (0.13) 2 places M2.6 X 0.45 depth 3 (0.12) mounting screw R1 22 (0.8) 4.5 (0.2) 3 (0.1) 4/15/98 H110inli 10 (0.4) R2 20 (0.8) 12 (0.5) 3 (0.1) 67 SOLENOID VALVE DIMENSION DIAGRAMS (mm) in. H110-4E2 S2 mm (in) 24 (0.9) 15 (0.6) Manual override 5 places 10-32 UNF 31 9 (1.2) (0.4) 118 (4.7) A 59 (2.3) S1 3 (0.1) 6 (0.2) 4/15/98 H110inli R1 A 5 (0.2) 2 places ø mounting hole 3 (0.12) ø counterbore 3 (0.11) depth 5 (0.21) Manual override 3 (0.1) 6 (0.2) 10 5 (0.2) (0.4) P B B 9 (0.4) PR 5 (0.2) R2 PR 5 10 (0.2) (0.4) 2 places ø mounting hole 3 (0.13) 5 (0.2) 67B SOLENOID VALVE DIMENSION DIAGRAMS (mm) in. H113-4E2 24 (0.9) 15 (0.6) S2 Manual override mm (in) 61 (2.4) 5 places 10-32 UNF 33 (1.3) 9 (0.4) 9 (0.4) 130 (5.1) PR 5 (0.2) 5 (0.2) A R1 A P B B R2 5 (0.2) 41 (1.6) 10 (0.4) 10 (0.4) PR 69 (2.7) 2 places ø mounting hole 3 (0.12) ø counterbore 3 (0.11) depth 5 (0.21) S1 2 places ø mounting hole 3 (0.13) Manual override 5 (0.2) 3 (0.1) 3 (0.1) 6 (0.2) 6 (0.2) 4/15/98 H110inli 67C 4/15/98 H110inli 68 8/1/97 H111NC 69 8/1/97 HA110sub 70 8/1/97 HA110sub 71 4/15/98 H110inli 72 4/15/98 H110inli 73 8/1/97 MiniMyte 74 8/1/97 MiniMyte 75 8/1/97 MiniMyte 76 8/1/97 MiniMyte 77 IN/NO 28.4 (1.1) sq. 2 Places #66 Terminals 0-13 (3.3) wide x 0.03 (0.08) THICK 81.3 (3.2) EXH/NC 2 Places ø 5.3 (0.2) OVERRIDE #10-32 EXT. Air piolt (AE1) version only 35.6 (1.4) IN 3 Places 1/8 NPSF 41.1 (1.6) OVERRIDE 76.5 (3.0) EXH 5.6 (0.2) 31 15.5 (1.2) (0.6) 4 Places #4-40 x 0.25 (6.4) mounting holes on 0.84 (21.3) sq. 16.3 (0.6) 11.9 (0.5) 5.1 (0.2) 3 Places 4.6 (0.2) wide x 6.9 (0.3) (8-137A) SIDE MOUNT 1/15/98 125E1LW 15 (0.6) 24.9 (1.0) 8.4 (0.3) 9.7 (0.4) 9.7 (0.4) (8-136A) BASE MOUNT CYL OVERRIDE CYL 29.5 (1.2) 25.4 (1.0) Per station 3.6 29 (0.1) (1.1) IN NC 28 EXH NO (1.1) 21.6 EXH NC (0.9) IN NO 22.4 (0.9) 2 Places 1/4 NPSF Each end CYL CYL CYL 1/8 NPSF 78 1/15/98 125E1LW 79 1/15/98 125E1LW 80 310Tech Humphrey 5/28/98 81 82 310Tech Humphrey 5/28/98 310Tech Humphrey 5/28/98 83 84 310Tech Humphrey 5/28/98 in (mm) 3 places 1/8 - 27 NPSF OUT 0.75 0.38 (19) (9.5) 0.62 (15.6) 2 places ø through hole 0.16 (4.00) 0.1 (2.5) 1.25 (31.7) 0.87 (22.1) 0.66 (16.7) 0.46 (11.7) 1.06 (27.0) 0.32 (8.1) 0.3 (7.6) 2 places ø 0.2 (5.1) 1.14 (29) 0.6 (15.2) 0.28 (7.1) 2.4 (60.4) 0.28 (7) 0.28 (7) 0.48 (12.1) IN EXH 0.87 (22.1) 310inlin Humphrey 1/16/98 85 in (mm) 0.46 (11.7) 4 places 1/8 - 27 NPSF 0.48 (12.1) 1 1.23(31.2) 0.28 (7) 2 places ø through hole 0.16 (4.00) 1.25 0.65 (31.8) (16.5) 2.7(68.6) 1.06 (27.0) 0.64 (16.3) 2 0.32 (8.1) 0.3 (7.6) 2 places ø 0.2 (5.1) 1.14 (29) 0.6 (15.2) 0.26 0.68 (6.5) (17.3) 0.36 (9.1) EXH IN 0.28 (7) 0.48 (12.1) 0.75 (19) 1.01(25.6) 310inlin Humphrey 1/16/98 86 0.46 (11.7) 0.64 (16.3) 4 places 1/8 - 27 NPSF 2 1 2 0.48 (12.1) 1 1.23 (31.2) 0.28 (7) 2 places ø through hole 0.16 (4) 1.25 (31.8) 1.06 (27.0) 0.32 (8.1) 0.3 (7.6) 2 places ø 0.2 (5.1) 1.14 (29) 0.6 (15.2) 0.65 (16.5) 2.70 (68.6) 0.26 0.68 (6.5) (17.3) 0.36 (9.1) IN EXH 1.01 (25.6) 0.22 (5.6) 0.28 (7.0) 0.48 (12.1) 0.75 (19.0) 310inlin Humphrey 1/16/98 87 310inlin Humphrey 8/01/97 88 S310 Humphrey 1/28/98 89 S310 Humphrey 1/28/98 90 in (mm) 2 places 0.22 (5.5) slotted for #10 screw 1.86 (47.2) 1.64 (41.7) 0.39 (9.8) 1.10 (28.1) 0.22 (5.6) 0.75 (19) TYP S410 S410-70 0.44 (11.1) TYP 2 places 1/8 - 27 NPSF S310 0.28 (7) 0.38 (9.5) THESE DIMENSIONS ARE TYPICAL FOR THE ADDITIONAL PORTS IN ALL SMP 310 & SMP 410 BODIES 1/8 - 27 NPSF (TYP) 1 1 OUT 1.26 (32) 2 0.67 (17) 2 0.38 (9.5) 0.48 (12.1) 0.28 (7) 0.48 (12.1) 2 places each end 1/4 - 18 NPSF 2.82 (71.5) 0.65 (16.4) 2 1 0.28 (7) 1.98 1.76 (50.4) (44.8) 2 places each end 0.34 (8.6) 1.12 (28.5) 0.40 (10.3) S310 Humphrey 1/28/98 0.94 (23.9) 91 in (mm) 2 places 0.22 (5.5) slotted for #10 screw 1.64 (41.7) 1.86 (47.2) 0.39 (9.8) 1.10 (28.1) 0.22 (5.6) 0.75 (19) TYP S410 S410-70 0.44 (11.1) TYP 2 places 1/8 - 27 NPSF S310 0.28 (7) 0.38 (9.5) THESE DIMENSIONS ARE TYPICAL FOR THE ADDITIONAL PORTS IN ALL SMP 310 & SMP 410 BODIES 1/8 - 27 NPSF (TYP) 1 1 OUT 1.26 (32) 2 0.67 (17) 2 0.38 (9.5) 0.48 (12.1) 0.28 (7) 0.48 (12.1) 2 places each end 1/4 - 18 NPSF 2.82 (71.5) 0.65 (16.4) 2 1 0.28 (7) 1.98 1.76 (50.4) (44.8) 2 places each end 0.34 (8.6) 1.12 (28.5) 0.40 (10.3) S310 Humphrey 1/28/98 0.94 (23.9) 92 in (mm) 2 places 0.22 (5.5) slotted for #10 screw 1.64 (41.7) 1.86 (47.2) 0.39 (9.8) 1.10 (28.1) 0.22 (5.6) 0.75 (19) TYP S410 S410-70 0.44 (11.1) TYP 2 places 1/8 - 27 NPSF S310 0.28 (7) 0.38 (9.5) THESE DIMENSIONS ARE TYPICAL FOR THE ADDITIONAL PORTS IN ALL SMP 310 & SMP 410 BODIES 1/8 - 27 NPSF (TYP) 1 1 OUT 1.26 (32) 2 0.67 (17) 2 2 places each end 1/4 - 18 NPSF 2.82 (71.5) 0.65 (16.4) 2 1 0.28 (7) 1.98 1.76 (50.4) (44.8) 0.38 (9.5) 0.40 (10.3) 0.48 (12.1) 0.28 (7) 0.48 (12.1) 2 places each end 0.34 (8.6) 1.12 (28.5) S310 Humphrey 1/28/98 0.94 (23.9) 93 S310 Humphrey 1/28/98 94 S310 Humphrey 1/28/98 95 8/1/97 M310 96 8/1/97 M310 97 8/1/97 M310 98 1 place each end 0.22 (5.6) slotted for #10 screw 1.25 (31.7) 0.75 (19.0) TYP 2.85 (72.4) 0.20 (5.1) 0.44 (11.1) TYP 2 places each end 1/4 - 18 NPSF 3.25 (82.6) EXH 2.00 (50.9) 1.58 (40.3) 0.92 (23.4) 2 2 2 1 1 1 0.48 (12.1) 1.26 (32.0) 0.61 (15.6) IN 1.7 (43.2) 0.44 (11.0) These dimensions are for the additional ports in the SBMP-1 subbase only 1/8 - 27 NPSF 0.78 (19,8) 1.62 (41.3) 0.28 (7.0) These dimensions are typical for the SB-1 and SBMP-1 subbases 8/1/97 M310 0.44 1.08 (11.3) (27.3) 98a 102 1.625 (41.275) 1.010 (25.654) in(mm) _ .102) dia. as req'd _ .004( + .344(8.737) + _ _ + + .500(12.7) .004 ( .102) c'bore x _ .007( + _ .178) deep .050(1.27) + .086 (2.184) .456 (11.824) .189 (4.800) .196 (4.978) 3 places _ .004( + _ .101) dia. as req'd .172(4.369) + _ .101) c'bore x _ .004( + .3125(7.937) + .185 _ .007 ( + _ .178)deep .050(1.27) + .029 (.737) .386 (4.699) .403 (9.804) .821 (20.853) (10.236) 8/1/97 M310 .750 (19.05) .664 (16.866) 2 places tap drill as req'd 3-48 UNC-2B x .200(5.08) min full thd _ .015( + 45 chamfer to .124(3.149) + _ .381) dia. 99 8/1/97 M310 100 8/1/97 M310 101 R310/R410 The R310/R410 manifold raceway assembly is made up of a manifold, a raceway, and valves. The manifold raceway assembly is available as a NEMA 4 rated assembly and is factory tested for sealing integrity. The raceway is one piece of co-extruded plastic enclosing an integral printed circuit board. The integral printed circuit board eliminates bulky wiring associated with other raceway systems. The circuit board has a surge suppression diode, LED, and reverse polarity protection for each station. The LED’s are visible through the red, transparent part of the raceway. The valves are available in 2-way, 3-way, and 4way models. The ability to mix valve models allows the manifold raceway assembly to be very flexible in meeting your Block-off specific needs. A non-locking plate manual override is standard on prefix “R” valves. Prefix “RN” valves are available only without manual override. The manifold is a rugged piece of extruded aluminum that is anodized for corrosion resistance. Also, all ports are available in metric sizes. R310/R410 valves Manifold Co-extruded plastic LEDs Manifold raceway assemblies are shipped factory pre-assembled, according to your order, can have from four to 16 stations, and are available in 12 and 24 VDC. D-sub connector The manifold raceway assembly interfaces with your equipment using a D-sub connector. All NEMA 4 assemblies have a 25-pin D-sub connector regardless of the number of stations (4 to 16). The chart below lists the breakdown of D-sub connector availability: D-Sub connector Number of stations 9 pin 15 pin 25 pin 4, 5, 6 7, 8, 9, 10, 11, 12 13, 14, 15, 16 Manifold raceway’s are tested and fully operational when shipped, simply plumb the manifold, plug in the D-sub connector, and you’re ready to go. R310Race 8/1/97 R310/R410 All valves plug-in for quick and easy changes. Use block-off plates to suspend the use of any station or to permit future valve additions. R A P B MANIFOLD RACEWAY SPECIFICATIONS Pressure range Vacuum range Ambient temperature range Voltage Weight Raceway materials 0 - 125 psig (0 - 8.5 bar) 0 - 28” Hg. (prefix “V” 3-way and all 4-way models) 32° to 124° F (0° to 50° C) 12 or 24 VDC internal circuitry not grounded to manifold. .37 lbs., plus .49 lb. per station Rigid PVC, nylon, steel, buna 6.50 (165.1) REF FOR 6 STATION ASSEMBLY AS SHOWN 3.70 (94.0) 2.08 (52.8) 1.53 (36.1) 0.44 (11.2) ADD 0.76 (19.3) REF FOR EACH ADDITIONAL STATION 0.20 (5.1) R 1/8-27 NPSF 3.25 (82.6) 0.63 (16.0) 0.50 (12.7) A 1.67 (42.4) P 0.22 (5.6) SLOT FOR #10 SCREW 1 PLACE EACH END 1.28 (32.5) P= supply port R= captured exhaust R310Race 8/1/97 1/4-18 NPSF 2 PLACES EACH END B #10-24 UNC 2B THD. 0.50 DEEP 1 PLACE EACH END Delivery ports: A= normally closed B= normally open 0.22 (5.6) inch (mm) R310/R410 HOW TO ORDER Unless specified otherwise the D-sub connector is located on the left end of the manifold (as viewed with the delivery ports facing you). Valve station number one will always be that station closest to the D-sub connector. Order manifolds first. Order the valves next with station position requested. Remember, option codes marked STD and NA are not used as part of the model number. All other options must be specified when ordering. MANIFOLDS MODEL RM * RM * R RM * N RM * NR DESCRIPTION D-sub connector on left side (standard) D-sub connector on right side D-sub connector on left side (standard)-NEMA 4 D-sub connector on right side-NEMA 4 * Specify number of stations (4 minimum, up to 16 maximum). To order metric ports include E as a model number prefix, example ERM-7-R. Include SA (ship assembled) as a model number suffix, example RM-7-R-SA. VALVES OPTION DESCRIPTION FLOW CONTROL LOCKING MANUAL OVERRIDE NO FLUORO- OVERRIDE ELASTOMER Option Code R310 (3-way plug-in) R410 (4-way plug-in) RN310 (3-way plug-in, NEMA 4) 70 NA 81 SP 87 SP VAI SP STD SA 12 / 24 VDC SP SP SP SP STD SA 12 / 24 VDC NA NA STD SP NA SA 12 / 24 VDC RN410 (4-way plug-in, NEMA 4) SP NA STD SP NA SA 12 / 24 VDC MODEL NON-LOCKING MANUAL SHIP OVERRIDE ASSEMBLED VOLTAGE • STD = Standard • N/A = Not available • SP = Specify (additional charges for this option) Consult the Humphrey Pneumatic Valves catalog for complete specifications on 310/410 Series Air Valves. ORDER EXAMPLES One, four station manifold assembly consisting of: 1 RM-4-SA 2 R310-SA 24VDC - Assy on Sta 1 & 2 1 R410-SA 24VDC - Assy on Sta 3 1 R410-70-SA 24VDC - Assy on Sta 4 D-SUB CABLES MODEL DESCRIPTION DS9 DS15 DS25 DS25N Three, six station manifold assemblies consisting of: 3 RM-6-NR-SA 9 RN310-VAI-SA 12VDC - Assy on Sta 1, 2 & 3 9 RN410-VAI-SA 12VDC - Assy on Sta 4, 5 & 6 NUMBER OF STATIONS 9-pin D-sub cable (120 in.) 15-pin D-sub cable (120 in.) 25-pin D-sub cable (120 in.) 25-pin D-sub NEMA 4 cable (120 in.) 4, 5, 6. 7, 8, 9, 10, 11, 12 13, 14, 15, 16 4 thru 16 Humphrey Products Company Kilgore at Sprinkle Road P.O. Box 2008 Kalamazoo, MI 49003 U.S.A Phone 616/381-5500 • Facsimile 616/381-4113 R310Race 8/1/97 © Copyright Humphrey Products Company 1995 3.24 (82.4) 1.60 (40.6) 3.25 (82.7) 1.60 (40.6) 1.13 (28.7) 2.44 (62.1) 3/4 - 14 NPSL EITHER END OR BOTH ENDS 1/19/98 310Racew 0.33 (8.3) 0.12 0.75 (3.0) (19.0) (COVERED ENDS) TYP (THREADED ENDS) 0.18 (4.6) 102 1/19/98 310Racew 103 315/415-1 315/415 SERIES Direct-Acting Solenoid Valves Humphrey 315/415 Series Valves Maximum Performance and Flexibility in a Compact Valve Until now, if you needed a compact direct-acting valve you had to accept a low small flow rate or limited functionality. Not anymore. The new Humphrey 315/415 Series valves deliver an unqualified 0.42 Cv flow rate in a 19mm-wide package. The key to the enhanced performance is the patent pending design -- a lip seal on the poppet allows the air inside the valve to help make a tight seal. This concept enabled Humphrey engineers to increase the flow rate -- up to three times higher than any other comparable valve -- yet keep the valve package small. Both the 315 Series 3-way valves and the 415 Series 4-ways valves can be mounted inline or on a common manifold. They can be oriented for normally-open, normally- closed, as a diverter, or as a selector. And the 415 Series valves are available with an optional sandwich speed control for manifold mounting. If you’re looking for performance and flexibility, look at the new Humphrey 315/415 Series valves. They’re part of the family of 300/400 Series valves designed and engineered for precise, reliable operation in a wide range of applications. Humphrey Products Company • 5070 East N Ave • Kalamazoo MI 49048 USA • T.616.381.5500 • F.616.381.4113 • www.humphrey-products.com 315/415 Series Direct-Acting Solenoid Valves • Low profile, high density two-gallery manifolds • Accepts 315 Series 3-way valves • Valves can be mounted for Normally Closed or Normally Open operation • Options include block off plates, isolator plugs, separate air supply plates and brackets for DIN rail mounting 315 Series Valve 415 Series Valve 315 two-gallery manifold • Direct-acting solenoid • New patent pending self-energizing seal • 0.42 Cv flow rate (ANSI (NFPA) T3.21.3 - 1990) • Rated from 28"Hg to 125 psig • NEMA 4 rated (IP-65) • Compact size (19mm width) • Low power consumption (5 watts) • 1/8" NPSF ports • Same body used for inline and manifold mounting Both valves shown with optional environmental cover for use in fluid applications / harsh environments. • Low profile, high density three-gallery manifolds • Common pressure / Individual exhaust ports • Accepts 415 Series 5-port, 4-way valves • Also accepts 315 Series 3-way valves • Valves can be mounted for N.C./N.O. operation • Options include block off plates, isolator plugs, separate air supply plates and brackets for DIN rail mounting 415 three-gallery manifold 315/415 Series Valves 315 Series 415 Series 4 2 2 Coil lead wires Coil lead wires (See specifications) (See specifications) 0.25 0.25 2 3 4 5 1 2.78 3 1 3 3.41 NOTE: PICTURED WITH OPTIONAL ENVIRONMENTAL COVER "EC" NOTE: PICTURED WITH OPTIONAL ENVIRONMENTAL COVER "EC" 1 5 315 Series Normal Condition 2 315 Series Actuated Condition ANSI Piping Diagrams 415 Series Normal Condition 1 3 415 Series Actuated Condition 315-415 Specifications Features: Line Mounted Line Mount ( 2 & 3 - Gallery Bar Stock Manifold) Port Sizes 315 1/8" NPSF 1/4" NPSF Inlet & Exhausts 415 1/8" NPSF Port Identifications 315 Valve: 315 Manifold: Pressure = 1; Cylinder= 2; Pressure= 1; Exhaust = 3; Exhaust= 3; 415 Valve: Pressure = 1; 415 Manifold: Cylinder = 2; Cylinder = 4; Pressure = 1; Exhaust = 3; Exhausts Ports = 3 & 5 Exhaust = 5 Cv (ANSI (NFPA) T3.21.3 - 1990) 0.42 SCFM @ 100 psig > 20 Fill/Exhaust Time 0 - 90 psi 1 cu.in. (.028 / .025 sec.) 10 cu.in. (.19 / .23 sec.) 100 cu.in.( 1.3 / 1.9 sec.) Voltage Tolerance Plus 10%, minus 15% of rated voltage Manifold Type 315 Series, 415 Series: Fixed Length Bar Stock ( 2 -12 Stations ) 2,4,6, etc...(Tap 1/4" NPSF) Sandwich Speed Control 315: N/A 415: Yes Coil Temperature Rise 95º F (any voltage) Rotatable Coil Yes - Field Adjustable 180º 415: 2-Position / Valve Function 315: Multi-purpose 5-Ported / 4 - Way 2-Position / 3 -Way Override Type Push Non-Locking (Momentary) Std. Electrical Connections 22 AWG Black Cross Linked Polyethylene insulated lead wire 7 x 30 stranded/tinned copper conductor; 125º C / 600 V. UL Style 3173,3271, CSA Type CL 1251. & DIN 43650C 15mm style connector Lubrication None required, factory pre-lubed Voltages 12VDC, 24VDC, 24 50/60, 120 50/60, 240 50/60 Flow Rates / Cv Humphrey recommends "fill/exhaust" times which are related to various chamber sizes, as the best method for calculating total valve and device (i.e., cylinder) response time. Humphrey recognizes the industry's use of flow coefficient Cv as a comparison standard. Consequently, Humphrey offers three types of flow data. The National Fluid Power Association's (NFPA) standards for Cv, the SCFM flow rate determined by flowing to atmosphere, and Humphrey's preferred "fill/exhaust times." Model Cv 315 415 0.42 0.42 SCFM @100 PSIG >20 >20 Fill Time (Sec) (0 to 90 PSIG) Chamber (cu. in.) 1 10 100 .028 .19 1.3 .028 .19 1.3 Exhaust Time (Sec) (100 to 10 PSIG) Chamber (cu. in.) 1 10 100 .025 .23 1.9 .025 .23 1.9 Solenoid Circuit Schematics AC/DC with Flying Leads AC / CODE 50 DC DC AC/DC with DIN Connector FRAME FRAME AC / CODE 50 DC DC Features: Line Mounted Line Mount ( 2 & 3 - Gallery Bar Stock Manifold) Power Consumption (AC/DC) Stroke (inches) Surge Suppression Weight 5 Watts 315 / 415: 0.022 (nominal) TSD - Option Code 50 315: .315 lbs. (5.04 oz) 415: . 90 lbs. (6.24oz) Agency Approvals Consult Factory Type of Operation Direct Acting Solenoid Coil General Purpose Class B, continuous duty rated, encapsulated. Mounting Position Any Media Air, Inert Gases Pressure Range 28" Hg Vacuum to 125 psig Filtration 40 Micron recommended Response Time 315: 0.020 / 0.008 (DC) ON/OFF (Sec.) 415: 0.020 / 0.021 (AC) Effective Area (Sq. In.) 0.125 Maximum Cycle Rate (CPM) 2142 (DC); 1463 (AC) Materials Buna-N, Brass, Anodized Aluminum, optional fluoroelastomer Ambient Temp Range 32º F to 125º F Leak Rate (max.) 4 cc/minute @ 100psig Package Rating NEMA 4 (IP-65) Dimensions (inches) 315 Series: .75 x 1.44 x 3.03 415 Series: .75 x 1.44 x 3.66 Coil Testing All valves are "HiPot" tested between coil windings and coil frame DIN Connector DIN 43650C 15mm style (9.4mm pin spacing) Specification DIN Rail Mounting (35mm) 315: Yes 415: Yes Response Times Identification of response time areas T1 times are measured from point (1) (coil energized) to point (2) (10% of supply pressure). T3 times are measured from point (4) (coil de-energization) to point (5) (10 % of supply pressure exhausted from outlet port). T2 times are measured from point(2) (detection of outlet pressure) to point (3) (90% of supply pressure). T4 times are measured from point (5) (detection of pressure drop) to point (6) (90% of supply pressure exhausted ) AC/DC Voltages (Same for both 315 & 415 Series Valves) Voltage AC DC T1 T2 T3 T4 .018 .002 .018 .003 .018 .002 .005 .003 Time in seconds Electrical Specifications Voltage 12VDC Resistance (Ohms) +/- 10% 28.8 Ω 115.2 Ω 80.0 Ω 2420.0 Ω 9680.0 Ω 24VDC • All coils come standard with 24 50/60 24-inch black lead wires. 120VAC • Optional 72-inch lead wires 240VAC are available Option Code ( LL ). • Optional DIN connectors (Option Code 39) • All AC coils are rated for 50/60 Hertz. • All coils utilize Class B insulation materials. • Resistance and current are nominal values. • Valves are "HiPot" tested • Ensure proper voltage supply per voltage label rating, +10% / -15% for AC or DC voltages. Current (Milliamps) 420 mA 210 mA 282 mA 47 mA 23 mA MANIFOLDS 315 SEPARATE AIR SUPPLY PLATE 315 MANIFOLD ENDPLATE 315 Manifolds 315 MANIFOLD STATION BLOCK-OFF PLATE 1 3 MOUNTING: (SEVEN STATION MANIFOLD SHOWN) DIN RAIL CLIP 415 MANIFOLD ENDPLATE 415 Manifolds DIN RAIL 415 SEPARATE AIR SUPPLY PLATE 415 MANIFOLD STATION BLOCK-OFF PLATE (w/ SPEED CONTROL) 3 1 5 (w/o SPEED CONTROL) MOUNTING: (SEVEN STATION MANIFOLD SHOWN) DIN RAIL CLIP DIN RAIL Accessories Speed Control: 415-SC* (includes (2) screws and (3) o-ring seals) Manifold Station Block-off Plates: 315-BOP*; 415-BOP* Manifold Plug (For use with 315 Series valves when mounted on a 415 Series manifold): 40062-1*; 40062-5* (bag of five) 315 Manifold End Plate: 315M-EP* (includes (2) end plates, (4) screws and (4) o-ring seals) 415 Manifold End Plate: 415M-EP* (includes (2) end plates, (4) screws and (6) o-ring seals) 315 Separate Air Supply Plate: 315-SSP* (includes (2) screws and (2) o-ring seals) 415 Separate Air Supply Plate: 415-SSP* (includes (2) screws and (3) o-ring seals) Isolator Plug: DP* (For applications requiring two different pressures, or pressure and vacuum. Refer to Multi-pressure Manifolds section for further information and considerations.) Valve Mounting Kits: 315-MK* (includes (2) screws and (2) o-ring seals; 415-MK* (includes (2) screws and (3) o-ring seals) NOTE: ( * ) indicates optional Fluoroelastomer seals. Specify suffix Option Code: VAI. Order Examples: 315-BOP VAI; 315-EP VAI DIN Rail Clip: DRC (kit includes (2) clips and (2) screws) HOW TO ORDER How to Order Valves Model NOTE: Standard valves are furnished with 24-inch flying leads and a push, non-locking manual override. Option codes marked STD and NA are not used as part of the model number when ordering. OS indicates that the Option must be ordered separately and is not used as part of the Model Number. NA = Not available OS = Order separately, additional charge for this option STD = Standard SP = Specify, additional charge for this option 315 415 Specify Voltage Option Code No Environ- Rotate Coil Fluorowith Mounting DIN DC Surge 72" Manual mental 180º from elastomer 12VAC seals 2-way Bracket Connection Suppression Leads Override Cover Standard* 24VAC 24VAC 50/60 87 EC RC VAI 2 21 39 50 LL 120VAC 50/60 SP 240VAC 50/60 SP SP SP SP SP SP SP SP NA * Coil is field-adjustable 180º, or may be ordered from factory, rotated. Standard Valve Order Example: Model 315-21-39-EC-120 50/60 A 1/8 inch pipe plug is included with each valve unit when ordering Option Code #2. DIN Connector (Socket) Options Model HS-2 DIN connector (only) for use with Option Code 39 Model HS2L DIN connector with light for use with Option Code 39 (12VDC, 24VDC only; specify voltage.) Model HS2 LED DIN connector with LED for use with Option Code 39 (12V, 24V, 120 VAC; specify voltage.) Model HS2-CLL Molded (6) ft. cable and assembly for use with Option Code 39 (DIN Connector). Note: DIN Connector Options must be ordered separately. How to Order Manifolds Model / 315 Series 315 Manifold Manifold type Tap Port Identification Sandwich Speed Control Speed control sandwich mounts between the 415 Series valve unit and manifold assembly. The Speed Control is intended to be used for the metering of the compressed air flow from cylinder to exhaust (i.e., Port 2 - 3 and Port 4 - 5). For optimal access to the adjustment screws, we recommend that the adjustment screws be positioned on the same end as the valve unit's manual override. Note: Since the Speed Control unit is symmetrical, it can be positioned on the same end as the solenoid. 315M-2 315M-8 415 Manifold 2-gallery, fixed length bar stock (2- 12 stations) 315M-3 315M-9 Manifold type 315M-4 315M-10 1/4” NPSF 315M-5 315M-11 Pressure = 1; Exhaust = 3 315M-6 315M-12 Assembly and Accessory Use Separate Air Supply Plate Model / 415 Series 415M-2 415M-8 3-gallery, fixed length bar stock (2- 12 stations) 415M-3 415M-9 415M-4 415M-10 Tap 1/4” NPSF 415M-5 415M-11 Port Identification Pressure = 1; Exhaust = 3 & 5 415M-6 415M-12 315M-7 Example: 315 Series 2 Station Manifold; Order: 315M-2 Metric Ports: Consult Factory 415M-7 Example: 415 Series 6 Station Manifold; Order: 315M-6 415 Series Valves (with optional environmental cover) Sandwich-style speed control mounts between a 415 Series 4-way valve and a three-gallery manifold. Manifold Station Block-off Plates Manifold End Plate 315 Series Valve (with optional environmental cover) Manifold Plug (Used to block off an exhaust port when using a 315 Series 3-way valve on a 415 manifold.) DIN Rail Clip 5 1 3 Isolator Plug (Insert plug into gallery, and when oriented, tighten screw to compress plug, forcing o-ring against gallery wall. Torque screw to 10-13 in/lbs. Be careful not to over-torque the screw.) COPY AND FAX To Your Local Humphrey Distributor To make it easier for you to obtain a quote on a completed valve/manifold assembly, please copy this form, fill in the appropriate part numbers for each station desired and fax it to your local Humphrey distributor. Valve/Manifold Assembly Request 315 Manifold 415 Manifold Top (T) 5 1 1 3 3 1 2 3 4 5 6 7 8 9 10 11 12 1 Please circle the number of stations desired on the drawing above. For each station having a valve, please indicate the complete Part No., including option codes and voltage, and whether you want the valve to be Normally Open or Normally Closed. For stations without valves, please specify under Accessory Part No. whether you want a Manifold Station Block-off Plate or a Separate Air Supply Plate. If you wish to isolate the manifold into two separate sections, please specify below where the Isolator Plugs should be. Valve Part No. Voltage Valve Orientation Accessories Part No. 2 3 4 5 6 7 8 9 10 11 12 Bottom (B) Please circle the number of stations desired on the drawing above. For each station having a valve, please indicate the complete Part No., including option codes and voltage, and any accessories, such as a Sandwich Speed Control or Block-off Plate. When using a 315 Series valve on a 415 Series manifold, please indicate whether you want the valve to be Normally Open or Normally Closed. Note; you also must order a Manifold Plug. For stations without valves, please specify under Accessory Part No. whether you want a Manifold Station Block-off Plate or a Separate Air Supply Plate. If you wish to isolate the manifold into two separate sections, please specify below where the Isolator Plugs should be. Station 1: ______________ ( ) [ ] N.O. [ ] N.C. _______________ Station 2: ______________ ( ) [ ] N.O. [ ] N.C. _______________ Station 3: ______________ ( ) [ ] N.O. [ ] N.C. _______________ Station 4: ______________ ( ) [ ] N.O. [ ] N.C. _______________ Station 1: ______________( ) [ ]T [ ]B [ ] N.O. [ ] N.C. ________________ Station 5: ______________ ( ) [ ] N.O. [ ] N.C. _______________ Station 2: ______________( ) [ ]T [ ]B [ ] N.O. [ ] N.C. ________________ Station 6: ______________ ( ) [ ] N.O. [ ] N.C. _______________ Station 3: ______________( ) [ ]T [ ]B [ ] N.O. [ ] N.C. ________________ Station 7: ______________ ( ) [ ] N.O. [ ] N.C. _______________ Station 4: ______________( ) [ ]T [ ]B [ ] N.O. [ ] N.C. ________________ Station 8: ______________ ( ) [ ] N.O. [ ] N.C. _______________ Station 5: ______________( ) [ ]T [ ]B [ ] N.O. [ ] N.C. ________________ Station 9: ______________ ( ) [ ] N.O. [ ] N.C. _______________ Station 6: ______________( ) [ ]T [ ]B [ ] N.O. [ ] N.C. ________________ Station 10:______________ ( ) [ ] N.O. [ ] N.C. _______________ Station 7: ______________( ) [ ]T [ ]B [ ] N.O. [ ] N.C. ________________ Station 11:______________ ( ) [ ] N.O. [ ] N.C. _______________ Station 8: ______________( ) [ ]T [ ]B [ ] N.O. [ ] N.C. ________________ Station 12:______________ ( ) [ ] N.O. [ ] N.C. _______________ Station 9: ______________( ) [ ]T [ ]B [ ] N.O. [ ] N.C. ________________ [ ] Isolator Plug(s) (Part No.) ________ GALLERY 1 between Station ___ and Station ____. Station 10:______________( ) [ ]T [ ]B [ ] N.O. [ ] N.C. ________________ (Part No.) ________ GALLERY 3 between Station ___ and Station ____. Station 11:______________( ) [ ]T [ ]B [ ] N.O. [ ] N.C. ________________ Station 12:______________( ) [ ]T [ ]B [ ] N.O. [ ] N.C. ________________ [ ] DIN rail clip 315 or 415 Series Valve Part No. Voltage 415 Series Solenoid Orientation 315 Series Valve Orientation Accessories Part No. [ ] Isolator Plug(s) (Part No.) ________ GALLERY 5 between Station ___ and Station ____. (Part No.) ________ GALLERY 1 between Station ___ and Station ____. (Part No.) ________ GALLERY 3 between Station ___ and Station ____. [ ] DIN rail clip Order Example This is an example of an order for a seven-station manifold assembly, based on the exploded drawing on the previous page. Troubleshooting Installation If valve fails to function when electrical power is supplied: 1) Check valve function using manual override. If valve functions by manual actuation, proceed to steps 2 and 3. If valve does not function, proceed to step 4. For valves without manual override, proceed to steps 2 and 3. 2) Check line voltage and compliance with valve electrical rating. 3) Check valve for inoperable (open) coil, measuring milliamps per Electrical Specifications Chart. 4) Check that the air supply has been delivered in adequate volume and pressure for proper functioning of the device. Ensure that there are no blockages due to air line contamination or defective/blocked fittings. Valves can be mounted in any position in most environments, in keeping with the specifications. 315/415 valves feature a Class B insulation system and molded coil for ambient temperatures from 32º F to 125ºF (0º to 50º C). Valves can be mounted by using the mounting holes provided. A DIN rail mounting clip is also available for manifolds. To order the DIN Rail Clip specify the DRC option code. Kit includes two clips and screws. Mounting Valves and Accessories to Manifolds 315 & 415 Series Valves: When mounting valves to manifold, ensure that a o-ring seal is properly located in each cavity of the manifold prior to mounting a valve unit. By rotating the 315 Series valve (180º), it can be converted from a 3-way Normally-Closed to 3-way Normally-Open function. Using screws furnished, tighten to 10-13 inch-pounds of torque. Be careful not to over-torque the screws. Accessories When installing the 415 Series Speed Control (# 415 SC ), take extra care to ensure that the o-rings are installed between the valve and speed control and speed control and manifold block. When connecting the Separate Air Supply (# 315-SSP or 415-SSP) and/or Block-off Plate (# 315-BOP, 415-BOP), to its manifold, install a o-ring in each cavity of the manifold prior to mounting the accessory item. Using screws furnished, tighten to 10-13 inch-pounds of torque. Be careful not to over torque the screws. Appropriate o-rings and mounting screws are furnished with each accessory item. Multi-pressure Manifolds To create a dual pressure (DP) manifold. Install the Isolator Plug (DP; DP-VAI) in-between the appropriate valve stations. See illustration and schematic on page 7. The accessory Isolator Plug (DP) has been pressure-tested to well beyond the rated limits of the valves, manifold and other accessory components. As such, it should remain fully functional in normal dual pressure or pressure/vacuum applications when all components are used within their rated limits. Humphrey Products cannot warrant the satisfactory performance of the Isolator Plug (DP) when any components are subjected to extreme environmental conditions such as excessive vibration, wide temperature variations, or other conditions beyond the control of Humphrey Products that might result in migration, leakage or failure of the Isolator Plug. Please determine the suitability of this product for your intended application prior to ordering and use. Lubrication Humphrey 315/415 Series valves can be operated with or without air line lubrication, depending on the application. If air cylinders or other devices require lubrication, ensure that the lubricating oils are chemically compatible with BUNA-N elastomers and are of sufficient viscosity to assure adequate lubrication. The equivalent to turbine oil Class 1 (ISO VG32) is recommended. Avoid using thin or low viscosity oils (spindle oil, machine oil, etc.) since they do not provide a good residual film of lubrication. Media / Pressure / Filtration Humphrey 315/415 Series valves are designed for use with compressed air or inert gases from vacuum service (28"Hg) to 125 psig. Media should be inert gas and/or clean, dry air. When in doubt, install a filter with filtering capacity of 40 microns or less. Periodically, remove and clean or replace filter element. Consult factory if using other media. Rotating the Solenoid (180 degrees) Humphrey 315/415 Series valves are designed to allow the end-user to rotate the coil 180 degrees, by the removal of two screws and then simply rotating the coil into position. Prior to rotating the coil, be sure that the supply pressure has been disconnected and properly vented from the valve prior to attempting this conversion. Be careful not to mis-align the gasket or internal spring when tightening the solenoid. Misalignment can prevent proper operation and/or shorten the life of the valve. Caution should be taken when doing this in the field. Warranty All valves have a one-year warranty from date of manufacture. This warranty includes repair and/or replacement at no charge should the product be deemed defective due to workmanship and/or material. (See detailed Product Warranty in Humphrey's General Valve Catalog.) Caution! Compressed air is powerful and may be dangerous. Before attempting to remove or service a component from an air line or system, always disconnect the supply air and thoroughly exhaust the line or system. Never attempt to construct, operate, or service anything using compressed air unless you have been properly trained to do so. Failure to heed this warning could result in PROPERTY DAMAGE AND/OR SERIOUS, EVEN FATAL, PERSONAL INJURY. The Humphrey 300/400 Family of Valves More Options for Size, Flow and Flexibility Humphrey now offers you more options for your applications. Our family of direct-acting pneumatic valves gives you a broad range of choices -- from the compact 310/410 Series with a .12 Cv, to the new compact, high performance 315/415 Series with a .42 Cv, up to the powerful 320/420 Series with a 1.0 Cv. 310/410 Series All valves are two-position, direct-acting single solenoid valves with a spring return. They can be used as Normally Open, Normally Closed or as a diverter. And all are designed and engineered for performance and reliability. 315/415 Series 310 Series • Multi-purpose 3-way • Three 1/8" ports • 0.12 Cv • 4.5 watts power consumption • Can be used on same manifold with 410 Series valves 315 Series • Multi-purpose 3-way • Three 1/8" ports • 0.42 Cv • 5.0 watts power consumption • Can be used on same manifold with 415 Series valves 410 Series • Multi-purpose 4-way • Four 1/8" ports • 0.14 Cv • 4.5 watts power consumption • Optional integral dual flow controls 415 Series • Multi-purpose 4-way • Five 1/8" ports • 0.42 Cv • 5.0 watts power consumption • Optional sandwich-style speed control 320/420 Series 320 Series • Multi-purpose 3-way • Three 1/4" ports • 1.0 Cv • 8.0 watts power consumption 420 Series • Multi-purpose 4-way • Four 1/4" ports • 1.0 Cv • 8.0 watts power consumption Humphrey Products Company • 5070 East N Ave • Kalamazoo MI 49048 USA • T.616.381.5500 • F.616.381.4113 • www.humphrey-products.com Custom solutions that really are custom. A lot of companies modify their standard products and call it "customization." But Humphrey can deliver a totally custom-engineered pneumatic solution that fits your unique application. Precisely. Perhaps you have an extremely tight space restriction. Starting with our miniature or micro valves, we can create a custom valve assembly to meet your performance requirements and form factor. Or you designed a complex system with hundreds of separate valves controlled by a PC or PLC -- and everything must be assembled correctly on site. We can engineer simple "Plug and Run" modules that snap together to eliminate the problems of plumbing and wiring individual valves. Maybe you want a valve manifold assembly with on-board diagnostics. Or an integrated digital control. Or both -and you want to connect all of them to your network. No problem. With our broad experience and control software expertise we can custom engineer the solution you've been looking for. Of course, we also offer a wide range of standard pneumatic components. All with decades of field-proven reliability. But when "standard" won't cut it, why settle for a compromise? Call us, and find out how easy it is to get exactly what you want. Humphrey Products Company • 5070 East N Ave • Kalamazoo MI 49048 USA • T.616.381.5500 • F.616.381.4113 • www.humphrey-products.com 8/1/97 H180inli 104 8/1/97 H180inli 105 8/1/97 H180inli 106 8/1/97 H180inli 107 8/1/97 H180inli 108 8/1/97 H180inli 109 8/1/97 H180inli 110 SOLENOID VALVE DIMENSION DIAGRAMS (mm) in. H181E1 4 (0.14) 34 (1.3) 27 (1.1) 18 (0.71) 15 (0.6) 4 (0.14) mm (in) Manual override 32 (1.3) 87 (3.4) 59 (2.3) 52 35 (2.0) 2 places (1.4) ø mounting hole 5 (0.18) 58 (2.3) 7 2 (0.3) (0.1) 10-32 UNF 3 places 1/4 NPT 12 (0.5) 25 (1.0) 27 (1.1) 24 (0.9) 30 (1.2) 12 (0.5) 48 (2.0) 12 32 (0.5) (1.3) 4/15/98 HA181NC 24 (0.9) 111T SOLENOID VALVE DIMENSION DIAGRAMS (mm) in. HA181E1 & HA181-25 4 (0.14) 34 (1.3) 27 (1.1) 18 (0.71) 15 (0.6) 4 (0.14) mm (in) Manual override 32 (1.3) 87 (3.4) 59 (2.3) 52 (2.0) 35 (1.4) 2 places ø mounting hole 5 (0.18) 58 (2.3) 7 2 (0.3) (0.1) 10-32 UNF 3 places 1/4 NPT 12 (0.5) 25 (1.0) 27 (1.1) 24 (0.9) 30 (1.2) 12 (0.5) 48 (2.0) 12 32 (0.5) (1.3) 4/15/98 HA181NC 24 (0.9) 111TB SOLENOID VALVE DIMENSION DIAGRAMS H180-4E1 (mm) in. 27 (1.1) 18 (0.71) 15 (0.6) Manual override mm (in) 24 (0.9) 2 places ø mounting hole 3 (0.13) 2 places ø mounting hole 3 (0.13) ø counterbore 6 (0.24) depth 3 (0.12) 87 (3.4) A 59 (2.3)30 (1.2) B 14 (0.6) PR 16 (0.6) 7 (0.3) 21 (0.8) A 21 (0.8) VIEW FROM A 2 places M3 x 0.5 depth 4 (0.16) 10 (0.4) 26 (1.0) P R2 29 16 (1.2) (0.6) 30 (1.2)B 14 (0.6) 5 places 1/8 NPT 0.5 (0.02) 7 (0.3) 0.5 (0.02) R1 A R1 P 10 (0.4) 5 (0.2) R2 5 (0.2) 0.5 (0.02) mm (in) 27 (1.1) 24 (1.0) 18 (0.7) H180-4E2 15 (0.6) S2 40 (1.5) 135 (5.3) 15 (0.6) 15 A (0.6) 15 (0.6) 15 68 (0.6) (2.7) B 2 places Manual override 2 places ø mounting hole3(0.13) 8 (0.3) ø counterbore 6 (0.24) depth 3 (0.12) 15 (0.6) A 15 (0.6) B 8 (0.3) 5places 1/8 NPT PR R1 13 (0.5) P 13 R2 (0.5) PR 2 places ø mounting hole 3 (0.13) S1 8/1/97 H180inli 0.5 (0.02) 7 (0.3) 0.5 (0.02) 7 (0.3) 21 (0.83) 112 SOLENOID VALVE DIMENSION DIAGRAMS (mm) in. H183-4E2 mm (in) 18 (0.7) S2 42 (1.7) 151 (5.9) 15 (0.6) 52 (2.1) 80 (3.2) 15 (0.6) A B 15 (0.6) 27 (1.1) 15 (0.6) 24 (1.0) 2 places Manual override 2 places ø mounting hole 3 (0.13) ø counterbore 6 (0.24) depth 3 (0.12) 8 (0.3) 15 (0.6) A 15 (0.6) B PR R1 P R2 13 (0.5) 13 (0.5) 8 (0.3) PR 5 places 1/8 NPT 2 places ø mounting hole 3 (0.13) S1 0.5 (0.02) 7 (0.3) 8/1/97 H180inli 0.5 (0.02) 7 (0.3) 21 (0.83) 112B 8/1/97 H180inli 113 MANIFOLD VALVE DIMENSION DIAGRAMS 5 (0.2) 10 (0.4) Manual override L note P note 19 19 (0.7) (0.7) 18 (0.7) 19 (0.7) 19 (0.7) (mm) in. 53 (2.1) 5 (0.2) 27 (1.1) 24 (0.9) 10 (0.4) 18 (0.7) mm (in) 25 (1.0) 11 (0.4) 5 (0.2) 2 places ø mounting hole 4 (0.17) 87 (3.4) 5 (0.2) 32 (1.3) 26 (1.0) 2 (0.1) A A 4 places 1/4 NPT (plugs 2 pcs.) R 19 (0.7) 1/8 NPT 38 (1.5) P 16 (0.6) 29 (1.1) 9 (0.4) H181E1, H180E1-11 Blockoff plate H181MA-BP 4/15/98 HA181NC 114 MANIFOLD VALVE DIMENSION DIAGRAMS (mm) in. mm (in) 5 (0.2) 10 (0.4) Manualoverride L note P note 19 (0.7) 19 19 (0.7) (0.7) 18 (0.7) 19 (0.7) 18 (0.7) 58 (2.3) 27 30 (1.1) (1.2) 24 24 (0.9) (0.9) 5 (0.2) 10 (0.4) 4 places ø mounting hole 4 (0.17) 87 (3.4) 17 (0.7) 10 (0.4) 2 places 10-32 UNF 4places 1/4NPT (plugs2pcs.) PR 50 (2.0) 2 (0.1) 46 (1.8) R 52 20 (2.0) (0.8) P 34 (1.3) 15 (0.6) 5 (0.2) HA181E1, HA180E1-11 Blockoff plate H181MA-BP 1/8 NPT 8 (0.3) A A A 21 19 (0.8) (0.7) 4/15/98 HA181NC 114B MANIFOLD VALVE DIMENSION DIAGRAMS (mm) in. mm (in) 53 (2.1) L note P note 5 (0.2) Manual override 19 19 (0.7)18 (0.7) (0.7) 10 (0.4) 19 (0.7) 19 (0.7) 27 (1.1) 24 (0.9) 5 (0.2) 4 places ø mounting hole 4 (0.17) 18 (0.7) 15 (0.6) 25 (1) 16 (0.6) 11 (0.4) 7 (0.3) 6 places 1/4 NPT (plugs 3 pcs.) 70 (2.8) 8 67 (2.7)39 (0.3) 7 (0.3) (1.5) A A A 20 (0.8) A B 8 (0.3) 1/8 NPT B B 19 (0.7) 0.5 (0.02) 58 (2.3) 42 (1.7) 42 (1.7) R1 R2 52 (2.1) P 22 (0.9)40 (1.6) 29 (1.1) 18 9 (0.7) (0.4) 80 (3.2) S1 S1 H180-4E1 H180-4E2 H180E1, H180E1-11 H183-4E2 Blockoff plate 4/15/98 HA180su 115 MANIFOLD VALVE DIMENSION DIAGRAMS (mm) in. mm (in) 55 (2.2) 5 (0.2) Manual 10 override (0.4) L note P note 19 19 (0.7) (0.7) 18 (0.7) 15 (0.6) 19 (0.7) 5 (0.2) 27 (1.1) 18 (0.7) A A A 20 (0.8) A B 8 (0.3) B R1 42 (1.7) B 1/8 NPT 27 (1.1) 21 (0.8) 13 11 (0.5) (0.4) 4 (0.2) 4 places 10-32 6 places 1/4 NPT (plugs 3 pcs.) 4 places ø mounting hole 4 (0.17) 70 (2.8) 8 (0.3) 39 7 (1.5) (0.3) 67 (2.7) 19 (0.7) 27 (1.1) 24 (0.9) P 68 (3.0) R2 74 40 (2.9) 26 (1.6) (1.0) 37 (1.5) 62 (2.4) 52 (2.1) 80 (3.2) 0.5 (0.02) S1 S1 H180-4E1 H180E1, H180E1-11 H180-4E2 H183-4E2 Blockoff plate 4/15/98 HA180su 115B MANIFOLD VALVE DIMENSION DIAGRAMS (mm) in. L note 5 (0.2) P note 19 (0.7) 10 (0.4) 1/8 NPT 19 (0.7) 19 (0.7) 18 (0.7) 19 (0.7) 5 (0.2) mm (in) 18 (0.7) 4 places ø mounting hole 4 (0.17) 10 (0.4) 35 (1.4) 35 (1.4) 68 (2.7) 74 (2.9) 29 (1.2) 10 (0.4) HA180-4A HA180-4A2 Blockoff plate A1 2 places 1/8 NPT per station 1 25 (1.0) 1 2 8 (0.3) 6 (0.2) 1 2 2 27 (1.1) 68 (2.7) 40 (1.6) 34 (1.3) 17 (0.7) 4 places 10-32 UNF 6 places 1/4 NPT 2 (0.1) R1 PR1 20 (0.8) PR2 R2 4/15/98 HA180su 31 (1.2) 20 (0.8) 31 (1.2) 116 4/15/98 HA180su 117 4/15/98 HA180su 118 8/1/97 H180inli 119 8/1/97 H180inli 120 Overrride located 0.81 (20.6) from bottom of valve body 30º 45º 2.5 (63.5)1.25 CYL. (31.8) 2.5 (63.5) 1.25 (31.8) IN EXH 1.53 (38.9) 1/2 NPSI 3.50 (88.9) 2.88 E2 2.25 (57.2) E2 (73.0) E1 1.94 (49.2) E1 0.69 (17.5) 062/125 Tyna-Myte 12/22/97 1.63 (41.3) 0.45 1/4 NPT (11.5) TYP 1.53 (38.9) 1/2 NPSI 4 places 1/4 NPT 0.59 (15.1) .38 (9.5) 0.06 (1.6) EXH IN 10-32 x 0.38 (9.5) deep on 0.88 (22.2) square centers valve body ø 0.22 (5.5) on ø 0.22 (5.5) on 2.00 (50.8) square centers 2.00 (50.8) square centers ø 1.63 (41.3) Cover rotates 360º 3 places 0.56 1/4 NPT 1/2 NPSI (14.3) 0.38 (9.5) CYL EXH 0.31 (7.9) IN Overrride located 0.81 (20.6) from bottom of valve body 0.31 (7.9) 0.06 (1.6) ø 1.63 (41.3) Bottom View 0.48 (12.3) 2.66 (67.5) 0.31 (7.9) 10-32 x 0.38 (9.5) DP 3.50 2.25 2.88 (88.9) (57.2) [E2] (73.0) [E2] [E1] 1.94 (49.2) [E1] See following Pages for more Tyna-Myte Air Valve Models and all specifications. Consult factory for air piloted vacuum options. 121 ø 0.56 (14.3) 22.00 (558.8) Min. 1/2-14 NPS Rotates 110° T125 SERIES T062/T062-4 SERIES ø mounting holes 0.20 (5.2) ø 0.16 (4.0) 1.38 (34.9) 0.47 (11.9) 0.47 (11.9) 0.91 (23.0) ø 0.33 (8.4) depth 1.7 (4.4) CYL 2 IN CYL 1 1.06 1.03 (26.8) (26.1) 10-32 x 0.28 (7.1) ø counterbore 0.20 (5.0) depth 0.13 (3.2) TO PORT 1 INLET TO PORT 2 0.80 (20.2) 0.50 (12.7) 0.56 (14.3) 0.41 0.41 (10.3) (10.3) 2 places 10-32 0.31 (7.9) screws 1.16 062/125 Tyna-Myte 12/22/97 125-4E1-36 Shown 4 way single sol. 1.24 (31.4) 1.38 (34.9) 0.62 (15.7) T062-4E1-70-80 Shown 4 way single sol. 1.06 (27.0) 0.98 (25.0) CYL 2 0.62 (15.7) T062E1-3-10-36-80 Shown 3 way single sol. 1/4 NPT Ea. end 0.28 (7.2) CYL 1 1.72 (43.7) 4.72 (119.9) 4.09 [E2] (104.0) [E1] 4.50 (114.3) 0.38 [125E2] (9.5) 0.38 (9.5) T125-4 SERIES 0.38 (9.5) 2.38 (60.3) 2.41 (61.1) 1.59 (40.5) 4 places 1/8 NPT 1.25 (31.8) 0.10 (27.8) (2.6) 2.19 (55.6) for 1 station add 2.38 (60.3) per additional station/s 122 Tyna - Myte™ Series Manifold and valves shown with optional Model JB junction boxes. 062/125 Tyna-Myte 12/22/97 123 062/125 Tyna-Myte 12/22/97 124 42E1Tac3 Electric 12/22/97 125 42E1Tac3 Electric 12/22/97 126 42E1Tac3 Electric 12/22/97 127 H240 Technical Section 12/21/97 132 H240 Technical Section 12/21/97 133 H240 Technical Section 12/21/97 134 H240 Technical Section 12/21/97 135 H240 Technical Section 12/21/97 136 SINGLE SOLENOID DOUBLE SOLENOID 2-POSITION DOUBLE SOLENOID 3-POSITION H240 Technical Section 12/21/97 138 H240 Technical Section 12/21/97 139 F Manifold H240 Technical Section 12/21/97 A Manifold B Manifold 140 AW Manifold H240 Technical Section 12/21/97 BW Manifold 141 H240 Technical Section 12/21/97 142 H240 Technical Section 12/21/97 143 H240 Technical Section 12/21/97 144 4/15/98 HW240 In-Line 144 SOLENOID VALVE DIMENSION DIAGRAMS (mm) in. H240-4E1 mm (in) 23 (0.9) 300 (12) 35 (1.4) 23 (0.9) Manual override 2 places Piston EXH 2 places ø couterbore3(0.13) depth 3 (0.12) 2 places ømountinghole3(0.13) 103.2 (4.1) 40 (1.6) 36 (1.4) E1 8 (0.3) 2 (0.1) 9 (0.4) 2 places depth 4 (0.16) 36 (1.4) IN 25.7 (1.0) 24.5 (1.0) 2 3 places (0.1) 1/4 NPT 9 (0.4) E2 19.6 (0.8) 22 (0.9) 15.5 (0.6) 2 places 1/8 NPT 3 (0.1) 17.5 (0.7) 3 (0.1) 11.5 (0.5) 11.5 (0.5) 7 (0.3) 7 (0.3) H240-4E2 300 (12) 23 (0.9) 35 (1.4) mm (in) 2places manual override 2 places ømountinghole3(0.13) 2 places øcouterbore3(0.13) depth 3 (0.12) 2 places 1/8 NPT PR E2 135.4 (5.3) 40 (1.6) 19.6 (0.8) 22 (0.9) IN 59 (2.3) E1 PR 5 (0.2) 47.7 (1.9) 67.7 (2.7) 49.7 (2.0) 57.9 (2.3) 3 places 1/4 NPT 9 (0.35) 2 (0.8) 9 (0.35) 2 (0.8) 4/15/98 HW240 In-Line 8 (0.3) 3 (0.1) 3 (0.1) 145 SOLENOID VALVE DIMENSION DIAGRAMS 23 (0.9) HA243-4E2 300 (12) S2 Manual override 2 places ø couterbore 3(0.13) depth 3(0.12) 165 (6.5) (mm) in. 35 (1.4) mm (in) 2 places ømountinghole3(0.13) E2 2 20 (0.8) 22 (0.9) 40 (1.6) E1 72 (2.8) 63 (2.5) S1 OPTIONS 4/15/98 HW240 In-Line 36 (1.4) IN 1 2 (0.1) 9 (0.4) 2 places 1/8 NPT PR PR 3 places 1/4 NPT 73 (2.9) 83 (3.3) 65 (2.5) Manual override 2 (0.1) 9 (0.4) 8 (0.3) 3 (0.1) 3 (0.1) 146 (mm) in. SOLENOID VALVE DIMENSION DIAGRAMS HA240-4E1-25 HA240-4E1-27 43 (1.7) 9 (0.4) 23 (0.9) Manual override 21 (0.8) 10 (0.4) 1/8 NPT 11 PR 103 (4.1) 21 55 (2.2) (0.8) 69 (27.0) E2 59 (2.3) E1 5 places 1/4 NPT 5.5 (0.2) 34 (1.3) 5 (0.2) mm (in) HA240-4E2-25 HA240-4E2-27 10 (0.4) 1/8 NPT 43 (1.7) 23 (0.9) 9 (0.4) S2 21 (0.8) 11 (0.4) 2 places manual override 39 (1.5) 35 (1.4) 43 (1.7) 28 (1.1) 21 (0.9) PR 55 21 A (2.2) (0.8) B 20 (0.8) 165 69 (6.5)(2.7) 2 places ¿ mounting hole 5 (0.17) 59 (2.3) E2 IN E1 53 (2.1) 5 places 1/4 NPT 4/15/98 HW240 Sub 83 (3.3) S1 5 (0.2) 40 (1.6) 30 (1.2) A 10 (0.4) 34 (1.3) 147 SOLENOID VALVE DIMENSION DIAGRAMS HA243-4E2-25 HA243-4E2-27 43 (1.7) 9 (0.4) 10 (0.4) 1/8 NPT 23 (0.9) 11 Manual override 21 (0.8) PR 103 (4.1) 21 55 (2.2) (0.8) 69 (27.0) E2 59 (2.3) E1 5 places 1/4 NPT 5.5 (0.2) 34 (1.3) 5 (0.2) 2 places ø mounting hole 5 (0.17) 83 (3.2) 300 (12.0) 39 (1.5) mm (in) 43 (1.7) 28 (1.1) 21 (0.9) 10 - 32 UNF E2 (Bottom view A) -27:Ports at the bottom 5 places 1/4 NPT IN E1 40 (1.6) 30 (1.2) 10 (0.4) A PR 40 23 55 (1.6) (0.9) (2.2) 30 18.5 (1.2) (0.7) 10 (0.4) 4/15/98 HW240 In-Line 11 (0.4) 25 (1.0) 35 (1.4) 148 OPTIONS 4/15/98 HW240 In-Line 148 b SOLENOID VALVE DIMENSION DIAGRAMS (mm) in. 43 (1.7) 21 (0.8) ø 10 (0.4) HW240-4E1-26 HW240-4E1-28 28 (1.1) 9 (0.4) 23 (0.9) 9 (0.3) 11 Manualoverride (0.4) 1/8 NPT Pilot EXH PE 53 (2.1) 5 places 1/4 NPT 10 (0.4) 139 (5.5) 103 (4.1) O2 O1 55 (2.2) 21 (0.8) 10 (0.4) 2 places ø mounting hole 5 (0.17) 21 (0.8) 5 (0.2) 34 (1.3) 6 (0.2) 83 (3.2) 43 (1.7) 9 (0.4) 59 (2.3) 69 (27.0) mm (in) 1/8 NPT Pilot EXH E2 IN E1 21 (0.9) 4/15/98 HW240 PLU 28 (1.1) 43 (1.7) 40 (1.6) 30 (1.2) 21 (0.8) 10 (0.4) A 21 (0.8) 10 (0.4) 55 (2.2) O1 PE O2 134 (5.3) 5 places 1/4 NPT 10 (0.4) 21 (0.8) 149 43 (1.7) 21 (0.8) 28 (1.1) 53 (2.1) 43 (1.7) S2 134 (5.3) 59 (2.3) E1 171 (6.7) 135 (5.3) 69 (27.0) 23 (0.9) 83 (3.2) 38 (1.5) 2 places ø mounting hole 5 (0.17) S1 A E2 9 (0.4) 9 (0.3) 11 Manualoverride (0.4) 9 (0.4) 40 (1.6) IN ø 10 (0.4) 5 (0.2) 34 (1.3) 21 (0.9) 28 (1.1) 43 (1.7) 30 (1.2) 21 10 (0.8) (0.4) (Bottom view A) -27:Ports at the bottom 10 - 32 UNF PE 5 places 1/4 NPT 23 (0.9) E2 40 (1.6) 55 (2.2) O2 IN E1 O1 30 10 19 (1.2) 11 (.4) (.7) (.4) 25 (1.0) 35 (1.4) 4/15/98 HW240 PLU 149 b OPTIONS 4/15/98 HW240 PLU 149 c H240 SERIES MANIFOLDS 4/15/98 HW240 In-Line 150 4/15/98 HW240 In-Line 151 SOLENOID VALVE DIMENSION DIAGRAMS H240M ■ F L P 5 (0.2) 12.5 (0.5) (mm) in. 24 (0.9) 24 (0.9) 24 (0.9) 23 (0.9) 5 (0.20) 24 (0.9) S2 S2 4 places ø mounting hole 5 (0.20) 68 (2.7) 2 99 (4.0) 2 2 2 22 (0.9) 20 52 62 79 165 (0.8) (2.1) (2.4)(3.1) (6.5) 103 (4.1) 25 (1.0) 37 (1.5) 1 5 (0.2) 2 (0.1) 1 1 1 21 (0.8) 2 (0.1) 52 (2.1) S1 2 places ø mounting hole 5 (0.17) S1 mm (in) 64 (2.5) HA240-4E1 HA240-4E2 HA243-4E2 35 (1.4) Blockoff plate 28 (1.1) 19 (0.8) 11 (0.4) 10 (0.4) 6 places ø 1/4 NPT EXH2 IN EXH1 40 16 (0.6) (1.6) 31 (1.2) 23 (1.0) 11 (4.3) 4/15/98 HW240 In-Line 152 SOLENOID VALVE DIMENSION DIAGRAMS 4/15/98 HW240 In-Line (mm) in. 152B SOLENOID VALVE DIMENSION DIAGRAMS (mm) in. H240M ■ A H240M ■ B 5 (0.2) L P 45 28 (1.8) (1.1) 23 33 (0.9) (1.3) 4 places ¿ mounting hole 5 (0.20) 13 (0.5) 44 (1.7) 3 (0.1) 29 15 (1.2) (0.6) 0.5 (0.02) 79 (3.1) 103 (4.1) 53 64 (2.1) (2.2) 79 (3.1) 166 (6.5) 3 (0.1) 27 (1.1) 0.5 (0.02) 8 (3.0) 39 (1.5) 35 (1.4) 42 (1.7) mm (in) 87 (3.4) 48 (1.9) 37 (1.5) 32 (1.3) 17 (0.7) 6 places ¿ 1/4 NPT E2 31 (1.2) IN E1 PE 42 16(1.6)27 (0.6) (1.04) 2 places ¿ 1/8 NPT 4/15/98 HW240 Sub 153 SOLENOID VALVE DIMENSION DIAGRAMS H240M ■ A H240M ■ B (mm) in. HA240-4E1 HA240-4E2 HA243-4E2 2 places 1/4 NPT Each station Blockoff plate 01 01 01 01 01 38 (1.5) 12 (0.5) 02 0.5 (0.02) 02 1 (0.04) 4 (0.2) 02 02 02 (Bottom view A) H240M B: Bottom ports E2 E2 02 22 47 (0.9) (1.9) IN 01 7 (2.4) 31 (1.2) 4/15/98 HW240 Sub 02 14 (0.6) 28 (1.1) E1 01 E2 E2 02 IN IN E1 41 30 (1.6) 16 (1.2) (0.6) E2 02 IN E1 01 5 places ¿ 1/8 NPT Each station IN E1 01 E1 01 14 (0.6) 28 (1.1) 8 (0.3) 31 (1.2) 153B SOLENOID VALVE DIMENSION DIAGRAMS (mm) in. H240M ■ A H240M ■ B 4/15/98 HW240 Sub 153C MANIFOLD VALVE DIMENSION DIAGRAMS (mm) in. 39 (1.5) 5 (0.2) 33 13(1.3) (0.5) 28 (1.1) 23 (0.9) 4 places ømountinghole5(0.20) S2 44 (1.7) S2 0.5 (0.02) S1 E1 31 (1.2) E1 42 (1.6) 16 (0.6) 3 42 8 (1.2) (1.7) (0.3) S1 17 (0.7) 6 (0.2) 2 places 1/2 NPT IN 64 (2.5) 168 53 (2.1) 79 (6.6) (3.1) 0.5 (0.02) mm (in) 6 places ø 1/4 NPT 111 (4.4) 126 (4.9) 15 79 (3.1) (0.6) 103 (4.1) 79 (3.1) 48 (1.9) 37 (1.5) 32 (1.3) 22 (0.8) PE 29 (1.6) 153 (2.1) 45 (1.8) L P 87 (3.4) 267 (1.0) 2 places ø 1/8 NPT (Bottom view A) H240M BW: bottom ports HA240-4E2 HA243-4E2Blockoff plate HA240-4E1 0.5 (0.02) 4/15/98 HW240 PLU 02 02 02 1 (0.04) 4 (0.16) 02 02 16 (0.6) 14 (0.6) 7(2.4) 31 28 (1.2) (1.1) E2 02 E2 01IN E1 01IN 30 41(1.6) (1.2) E2 02 47 (1.9) 22(0.9) 01IN E1 E2 02 01 01IN E1 01 E2 02 01 01IN E1 38 (1.5) 12(0. 5) 01 02 01 E1 2 places 1/4 NPT Each station 14 (0.5) 28 (1.1) 7.5 (0.3) 31 (1.2) 5 places ø 1/8 NPT each station 154 MANIFOLD VALVE DIMENSION DIAGRAMS 4/15/98 HW240 PLU (mm) in. 154B 320Technical 1/19/98 161 320Technical 1/19/98 162 320Technical 1/19/98 163 320Technical 1/19/98 164 1.73 (43.9) 1 (25.4) 2 places 0.42 ø 0.26 (6.7) (10.7) 0.36 (9.3) 3 places 1/4 - 18 NPSF in (mm) 1.98 (50.4) 1 0.5 (25.4) (12.7) OUT 0.8 (20.3) 1.01 (25.7) 2 places ø through hole 0.18 (4.70) 1.75 1.36 (44.4) (34.5) 1.36 (34.5) 3.76 (95.4) 0.2 (5) in (mm) 0.44 (11.2) 3.56 (90.4) [420] 3.20 (81.3) [320] 0.53 (13.5) 0.5 (12.7) IN EXH 1.4 (35.5) 2.45 (62.2) 320/420 In-Line 1/16/98 1/2 -14 NPSM 0.50 (12.7) 165 1.73 (43.9) 1 (25.4) 2 places 0.42 ø 0.26 (6.7) (10.7) 0.36 (9.3) in (mm) 0.91 (23.1) 4 places 1/4 - 18 NPSF 2 1 1.98 (50.4) 1.00 0.5 (12.7) (25.4) 0.8 (20.3) 1.77 (45) 2 places ø through hole 0.18 (4.70) 1.75 1.36(44.4) (34.5) 4.12 (104.6) 1.36 (34.5) 0.2 (5) 0.44 (11.2) in (mm) 3.56 (90.4) [420] 3.20 (81.3) [320] 0.53 (13.5) 0.5 (12.7) IN EXH 1.4 (35.5) 320/420 In-Line 1/16/98 1/2 -14 NPSM 2.45 (62.2) 0.50 (12.7) 166 320/420 In-Line 1/16/98 167 420 Manifold Mounted 12/21/97 2 420 Manifold Mounted 12/21/97 3 420 Manifold Mounted 12/21/97 8 420 Manifold Mounted 12/21/97 9 420 Manifold Mounted 12/21/97 10 420 Manifold Mounted 12/21/97 11 420 Manifold Mounted 12/21/97 12 420 Manifold Mounted 12/21/97 13 420 Manifold Mounted 12/21/97 14 Cover rotates at 90° intervals 1.56 (39.7) External pilot connection All AE1 and AE2 7/16-24 NS 2ANut and sleeve furnished ø1.63 (41.3) 1/2-14 NPT 5.25 (133.4) 3 places 1/2-14 NPTF EXH 3.75 (95.3) IN CYL 2.88 (73.0) 2.31 (58.7) 1.16 (29.4) 3.06 (77.6) [500] 4.00 (101.6) [590] 2.19 (55.6) CYL 2.44 (61.9) IN EXH 1/20/98 500elect 2.94 (74.6) [500] 3.47 (88.1) [590] ø 0.34 (8.7) 168 ø 1.63 (41.3) 1/2 NPSI Cover rotates at 90° intervals 1.13 (28.6) ø 0.38 (9.5) 3 places 1/2 NPTF 1.25 (31.8) 1.13 (28.6) 4 places 1/2-14 NPTF CYL 2.53 (64.3) 1.59 (40.5) IN 0.66 (16.7) 2.41 (61.1) 1.84 (46.8) 6.00 (152.4) 1.41 (35.7) CYL 2 EXH CYL 1 IN 2.78 (70.6) 2.75 (69.9) 1.38 (34.9) 0.19 (4.7) 1/4-20 depth 0.5 (12.7) IN Cover rotates at 90° intervals 5.69 (144.5) EXH 3.19 (81.0) ø 1.63 (41.3) 1/2-14 NPT Mounting base Code 21 1.41 (35.7) 0.31 (7.9) 0.38 (9.5) 3.00 (76.2) 0.94 0.94 (23.8) (23.8) 3.25 x 3.75 (82.6) (95.3) thick wide 2.00 (50.8) CYL 1.00 (25.4) 1.38 (34.9) 3.38 (85.7) 1/20/98 500elect 0.38(9.5) ø 0.38 (9.5) 169 1/20/98 500elect 170 Cover rotates at 90° intervals External pilot connection 1.56 All AE1 and AE2 7/16-24 NS 2A (39.7) Nut and sleeve furnished ø 1.63 (41.3) 1/2-14 NPT 5.25 3 places (133.4) 1/2-14 NPTF EXH 3.75 (95.3) CYL IN 2.88 (73.0) 2.31 (58.7) 1.16 (29.4) 3.06 (77.6) [500] 4.00 (101.6) [590] 2.19 (55.6) 2.94 (74.6) [500] CYL 2.44 (61.9) 3.47 (88.1) [590] IN EXH 1/20/98 500elect ø 0.34 (8.7) 171 1/20/98 500elect 172 1/20/98 500AP 204 Technical Section Poppet Diaphragm 8/10/97 Technical Section Poppet Diaphragm 8/10/97 174 Technical Section Poppet Diaphragm 8/10/97 175 Technical Section Poppet Diaphragm 8/10/97 176 Technical Section Poppet Diaphragm 8/10/97 177 4/15/98 H/HA110 Air Piloted 178 4/15/98 H/HA110 Air Piloted 179 H110-4A2 H110-4A 4/15/98 H/HA110 Air Piloted 180 AIR PILOTED DIMENSION DIAGRAMS H110-4A (mm) in. mm (in) 24 (1.0) 12 (0.5) 10-32 UNF 15 (0.6) 5 (0.2) 2 47 (1.8) 22 (0.9) 8 (0.3) 10-32 UNF 1 9 (0.4) A 9 (0.4) B 5 (0.2) 3 (0.1) 6 (0.2) 3 (0.1) 6 (0.2) 9 (0.4) 2 places ø mounting hole 5 (0.22) ø counterbore 3 (0.11) depth 3 (0.12) 9 (0.4) 5 (0.1) 5 (0.1) 2 places M 2.6 depth 3 (0.10) mounting screwhole 10-32 UNF 15 (0.6) H110-4A2 A2 2 mm (in) 24 (1.0) 8 (0.3) 12 (0.5) 10-32 UNF 9 (0.4) 5(0.1) R1 10 (0.4) 5 (0.2) A 50 (2.0) P B 1 25 (1.0) R2 5(0.1) A1 3 (0.1) 6 (0.2) 9 (0.4) 3 (0.1) 6 (0.2) A1 4/15/98 H/HA110 Air Piloted 5 (0.2) R1 10 (0.4) P 10 (0.4) R2 5 (0.2) 2 places ø mounting hole 3 (0.13) 5 (0.2) 2 places ø mounting hole 5 (0.21) ø counterbore 3 (0.11) depth 3 (0.12) 5 (0.2) 10 (0.4) 2 places ø mounting hole 3 (0.13) 5 (0.2) 181 AIR PILOTED DIMENSION DIAGRAMS (mm) in. ADDITIONAL PARTS (sold separately) H110-21 Mounting Base H110-21 mm (in) 52 (2.0) 5 (0.2) 2 (0.06) 24 (0.9) 2 places ø mounting hole 5 (0.18) 9(0.4) 9(0.4) 5 (0.2) 14 (0.6) 5 (0.2) 14 (0.6) 40 (1.6) Flow control HSCE-O1 Flow control HSCE-M5 21 (0.8) 4 (0.2) 21 (0.8) 12 (0.5) 9 (0.4) 10- 32 UNF HSCE-M5 4/15/98 H/HA110 Air Piloted 2 places 8 (0.3) 2 (0.1) surface to surface width 11 (0.4) 2 (0.1) surface to surface dimension HSCE-01 1/8 NPT 181B AIR PILOT VALUE DIMENSION DIAGRAMS 10-32 UNF 10-32 UNF 15 (0.6) 8 (0.3) (mm) in. 15 (0.6) 24 (1.0) 12 (0.5) mm (in) mm (in) 8 (0.3) 24 (1.0) 12 (0.5) A2 6 (0.2) 9 (0.4) 9 (0.4) 22 (0.9) 9 (0.4) 50 (2.0) 9 (0.4) 47 (1.8) 25 (1.0) A1 6 (0.2) 2 places ø mounting hole 5 (0.21) 6 ø counterbore 3 (0.11) (0.2) depth 3 (0.12) 6 (0.2) 2 places ø mounting hole 5 (0.22) ø counterbore 3 (0.11) depth 3 (0.12) A1 2 places 10-32 UNF 5 places 1/8 NPT 7 (0.3) PR1 2 R1 23 15 (0.6) (0.9) mm (in) P 15 (0.6) 7 (0.3) R2 1 23 (0.9) PR2 8 (0.3) 18 (0.7) 50 (2.0) 9 (0.4) 55 (2.2) 8(0.3) 11 (0.4) 18 (0.7) 20 (0.8) 25 (1.0) 18 (0.7) 9 (0.4) 22 (0.9) 6 (0.2) 12 12 (0.5) (0.5) 2 places ø mounting hole 3 (0.13) 6 (0.2) 30 (1.2) 4/15/98 H/HA110 Air Piloted 182 H110 SERIES MANIFOLDS 4/15/98 H/HA110 Air Piloted 183 MANIFOLD DIMENSION DIAGRAMS A B 4 (0.1) 4 (0.1) 16 (0.6) 9 (0.3) Manual override mm (in) (mm) in. 43 (1.7) 24 (0.9) 18 (0.7) 11 (0.4) 8 (0.3) 4 (0.2) 4 places1/8 NPT Plugs 2 pieces 6 (0.2) 23 (0.9) 15 (0.6) 2 places ø mounting hole 4 (0.17) 75 (2.9) 30 (1.2) A A 21 (0.8) R P 9 (0.3) 15 21 (0.6)(0.8) 3 (0.1) 14 (0.6) 7 (0.3) H111-E1 Blockoff plate NOTE: L = 1.890 (48) and P = 1.614 (41) for a 2 station manifold. Add .0630 (16) for each station over 2 [(example: for a 6 station manifold, add 2.520 (64), or L = 4.410 (112) and P = 4.134 (105)]. 4 (0.1) 9 (0.3) Manual override A B 16 (0.6) 4 (0.1) 15 (0.6) 53 (2.1) 24 (1.0) 28 (1.1) 23 (0.9) 16 (0.6) 2 places 8 (0.3) 10-32 UNF 4 places 1/8 NPT 2 places ø mounting hole 4 (0.17) 75 (2.9) 16(0.6) 42 (1.7) 39 (1.5) 5 (0.2) PR R 29 37 (1.1)(1.4) P 14 (0.5) HA111-E1 HA111-E1-11 1/8 NPT 8 (0.3) A Blockoff plate A A 19 16 (0.8)(0.6) NOTE: L = 1.890 (48) and P = 1.614 (41) for a 2 station manifold. Add .0630 (16) for each station over 2 [(example: for a 6 station manifold, add 2.520 (64), or L = 4.410 (112) and P = 4.134 (105)]. 4/15/98 H/HA110 Air Piloted 184 ø 1.19 (30.2) ø 1.00 (25.4) 125A NC ø 1.19 (30.2) ø 1.00 (25.4) 0.08 (2.0) ea. 1.56 (39.7) With base 1.25 (31.8) 1.50 (38.1) 0.63 Without base (15.9) 1/8 NPT 0.08 2.06 (2.0) (52.4) ea. With base 2.00 3 places 1.25 (50.8) 1/8-27 NPSF (31.8) Without base 0.63 1-20 UNEF x 0.22 (5.5) (15.9) 0.44 (11.1) 0.44 (11.1) CYL EXH 0.11 (2.8) 125A/AA, 125LA, 125AH 8/10/97 IN CYL EXH IN 3 places 1/8-27 NPSF 1-20 UNEF x 0.22 (5.5) 0.11 (2.8) 185 125A/AA, 125LA, 125AH 8/10/97 186 1.66 (42.1) With base 1.59 (40.4) 0.63 Without base (15.9) CYL EXH IN 3 places 1/8-27 NPSF 1-20 UNEF x 0.22 (5.5) 0.11 (2.8) 125A/AA, 125LA, 125AH 8/10/97 187 4/15/98 H/HA180 Air piloted 188 4/15/98 H/HA180 Air piloted 189 4/15/98 H/HA180 Air piloted 190 AIR PILOT VALVE DIMENSION DIAGRAMS (mm) in. 2 places ø mounting hole 3 (0.13) ø counterbore 6 (0.24) depth 3 (0.12) H180-4A 1/8 NPT 27 (1.1) 2 places ø mounting hole 3 (0.13) 18 (0.7) mm (in) 14 (0.5) 15 (0.6) A 64 (2.5) 29 (1.2) B 0.5 (0.02) 7 (0.3) 8 (0.3) 8 (0.3) 15 (0.6) 15 (0.6) R1 A P B R2 15 (0.6) 0.5 (0.02) 7 (0.3) 5 places ø port 1/8 NPT 13 (0.5) 13 (0.5) 6 (0.2) 10 (0.4) 2 places mounting screwhole 10-32 UNF 10 (0.4) 5 (0.2) 5 (0.2) H180-4A2 18 (0.7) A 70 (2.8) 35 (1.4) B 2 places 1/8 NPT 27 (1.1) 9 (0.4) 2 places ø mounting hole 3 (0.13) ø counterbore 6 (0.24) depth 3 (0.12) 15 15 8 (0.6) A (0.6) (0.3) 8 15 15 (0.3) (0.6) (0.6) B 14 (0.5) R1 P 13 (0.5) 13 (0.5) R2 5 places 1/8 NPT 1 (0.02) 7 (0.3) 1 (0.02) 7 (0.3) mm (in) 6 (0.2) A1 4/15/98 H/HA180 Air piloted 191 AIR PILOT VALVE DIMENSION DIAGRAMS (mm) in. ADDITIONAL PARTS (sold separately) H180-21: Mtg. base mm (in) 64 (2.7) 2 (0.6) 5 (0.2) 2 places ø mounting hole 5 (0.18) 10 26 (0.4) (1.0) 10 (0.4) 5 5 (0.2) (0.2) 17 17 (0.7) (0.7) 45 (1.8) 4/15/98 H/HA180 Air piloted 191B AIR PILOT VALVE DIMENSION DIAGRAMS (mm) in. 2 places ø mounting hole 3 (0.13) ø counterbore 6 (0.24) depth 3 (0.12) H180-4A 1/8 NPT 27 (1.1) 2 places ø mounting hole 3 (0.13) 18 (0.7) mm (in) 14 (0.5) 15 (0.6) A 64 (2.5) 29 (1.2) B 0.5 (0.02) 7 (0.3) 8 (0.3) 8 (0.3) 15 (0.6) 15 (0.6) R1 A P B R2 15 (0.6) 0.5 (0.02) 7 (0.3) 5 places ø port 1/8 NPT 13 (0.5) 13 (0.5) 6 (0.2) 10 (0.4) 2 places mounting screwhole 10-32 UNF 10 (0.4) 5 (0.2) 5 (0.2) H180-4A2 18 (0.7) A 70 (2.8) 35 (1.4) B 2 places 1/8 NPT 27 (1.1) 9 (0.4) 2 places ø mounting hole 3 (0.13) ø counterbore 6 (0.24) depth 3 (0.12) 15 15 8 (0.6) A (0.6) (0.3) 8 15 15 (0.3) (0.6) (0.6) B 14 (0.5) R1 P 13 (0.5) 13 (0.5) R2 5 places 1/8 NPT 1 (0.02) 7 (0.3) 1 (0.02) 7 (0.3) mm (in) 6 (0.2) A1 4/15/98 H/HA180 Air piloted 192 AIR PILOT VALVE DIMENSION DIAGRAMS (mm) in. SINGLE SUBBASE (sold separately) HA-180 - 25 (shown with HA-180-4A mounted) mm (in) 22 15 (0.9) (0.6) 15 (0.6) 10 (0.4) 71 (2.8) 10 (0.4) 10 (0.4) 36 (1.4) 7 7 (0.3)(0.3) 10 (0.4) 2 places 10-32 UNF 5 places 1/4 NPT 2 places ø mounting hole 5 (0.22) 14 14 (0.5) (0.5) 34 (1.3) 31 20 (1.2) (0.8) 20 (0.8) 31 (1.2) 10 (0.4) 15 (0.6) 25 (1.0) 30 (1.2) 58 (2.3) 4/15/98 H/HA180 Air piloted 192B H180 SERIES AIR PILOTED MANIFOLD VALVE 4/15/98 H/HA180 Air piloted 193 MANIFOLD DIMENSION DIAGRAMS (mm) in. 2-, 3-way H180M ■ F L note P note 5 (0.2) Manual override mm (in) 53 (2.1) 19 19 (0.7)18 (0.7) (0.7) 10 (0.4) 19 (0.7) 19 (0.7) 27 (1.1) 24 (0.9) 5 (0.2) 4 places ø mounting hole 4 (0.17) 18 (0.7) 15 (0.6) 25 (1) 16 (0.6) 11 (0.4) 7 (0.3) 6 places 1/4 NPT (plugs 3 pcs.) 70 (2.8) 8 67 (2.7)39 (0.3) 7 (0.3) (1.5) A A A 20 (0.8) A B 8 (0.3) 1/8 NPT B B 19 (0.7) 0.5 (0.02) 58 (2.3) 42 (1.7) 42 (1.7) R1 R2 52 (2.1) P 22 (0.9)40 (1.6) 29 (1.1) 18 9 (0.7) (0.4) 80 (3.2) S1 S1 H180-4E1 H180-4E2 H180E1, H180E1-11 H183-4E2 Blockoff plate 4/15/98 H/HA180 Air piloted 194 MANIFOLD DIMENSION DIAGRAMS L note H180M ■ A 5 (0.2) (mm) in. P note 19 (0.7) 10 (0.4) 1/8 NPT 19 (0.7) 19 (0.7) 18 (0.7) 19 (0.7) 5 (0.2) mm (in) 18 (0.7) 4 places ø mounting hole 4 (0.17) 10 (0.4) 35 (1.4) 35 (1.4) 68 (2.7) 74 (2.9) 29 (1.2) 10 (0.4) HA180-4A HA180-4A2 Blockoff plate A1 2 places 1/8 NPT per station 1 25 (1.0) 1 2 8 (0.3) 6 (0.2) 1 2 2 27 (1.1) 68 (2.7) 40 (1.6) 34 (1.3) 17 (0.7) 4 places 10-32 UNF 6 places 1/4 NPT 2 (0.1) R1 PR1 20 (0.8) PR2 R2 4/15/98 H/HA180 Air piloted 31 (1.2) 20 (0.8) 31 (1.2) 194B 0.63 (16.0) 1/8 x 27 NPSF EXH N/C 0.22 (5.6) 1.59 (40.4) IN CYL EXH N/O 2.25 (57.2) sq. 3 places 1/4 NPSF 2.88 (73.1) With base 2.78 1.88 (70.6) (47.8) Without base 0.97 (24.6) 250A/AA, 2508/10/97 0.06 (.15) CYL IN EXH N/O ø 1.63 (41.4) 2.06 (52.3) With base 1.97 (50.0) Without base 195 250A/AA, 2508/10/97 196 250A/AA, 2508/10/97 197 42A2 0.63(15.9) M42A2 0.52(13.1) 0.52(13.1) 1.13 EXH 0.88(28.6) (22.2) 0.75 C2 NC 0.38 (19.1) (9.5) IN C1 NO EXH C2 0.88 (22.2) IN 0.63(15.9) C1 EXH EXH (42A2) ONLY 1/29/98 TAC3AP 198 1/20/98 500AP 199 500A/AB/AG 590A/AB/AG 2.94 (74.6) [500] 4.00 (101.6) [590] 2.19 (55.6) 2.94 (74.6) [500] 4.00 (101.6) [590] 2.19 (55.6) 3.06 (77.8) 2.44 CYL. (61.9) [500] IN 3 places [500] 1/2-14 NPTF EXH 0.63 (15.9) 1/8-27 NPSF 0.63 (15.9) 2.75 (69.9) [A] EXH IN ø 0.34 (8.7) 3 places [500] 1/2-14 NPTF 3 places [590] 3/4-14 NPTF 1/8-27 NPSF 3 places [590] 3/4-14 NPTF 3.13 (79.4) [AB] IN 3.53 (89.7) [590] ø 0.34 (8.7) EXH 2.75 (69.9) [A] 3.06 (77.8) [500] CYL 2.44 (61.9) 3.53 (89.7) [590] 3.13 (79.4) [AB] 2.31 (58.7) CYL 1.16 (29.4) 501A IN CYL 2.31 (58.7) 1.16 (29.4) 8-50 0.19 (4.8) 0.56 (14.3) 2.75 (69.9) 1.38 (34.9) 1/8-27 NPSF 1/4 -20 depth 0.50 (12.7) ø 0.38 (9.5) 1/2-14 NPTF N/O [AA] EXH 3.19 (81.0) 1.25 (31.8) 2.53 (64.3) 1.59 (40.5) N/C [AA] IN 0.66 (16.7) 1.13 (28.6) CYL 3.38 (85.7) Mounting base Code 21 2.41 (61.1) 1.41 (35.7) 0.19 (4.8) 1/20/98 500AP IN 2.00 (50.8) CYL 1.00 (25.4) 1.38 (34.9) 3.38 (85.7) 0.38 (9.5) ø 0.38 (9.5) 199-a 1/20/98 500AP 200 501-4A 1/8-27 NPSF 501 4A ENG 4 places 1/2-14 NPTF CYL 2 EXH CYL 1 IN 3.31 (84.1) 1.41 (35.7) 0.31 (7.9) 1/20/98 500AP 0.38 (9.5) 3.00 (76.2) CTRS 0.94 0.94 (23.8) (23.8) 3.25 3.75 (82.6) x (95.3) wide thick 203 1/28/98 SQE1 201 1/28/98 SQE1 202 SQE #10-32 UNF-2A x 0.16(4.1) deep both ends 0.94(23.9) 0.09 (2.3) 0.66(16.8) 0.20 Ø 0.28 (5.1) 0.16 (7.1) 0.38 ø 0.28 (7.1) #10-32 (4.1) Typ. (9.6) 0.47 UNF-2B (11.9) 0.38 (9.6) EXH IN IN OUT S125 1.31(33.3) HUMPHREY S125 IN IN OUT ø .56 (14.3) 1/28/98 SQE1 .50 (14.3) wrench flats 229 VA125A, 250A, 500A, 590A 10/21/97 206 VA125A, 250A, 500A, 590A 10/21/97 207 VA125A, 250A, 500A, 590A 10/21/97 211 Y125IN, Y250IN, Y500IN, 125INL, 250IN 10/21097 208 Y125IN, Y250IN, Y500IN, 125INL, 250IN 10/21097 209 ø 1.63 (41.3) 1.88 (47.8) 2.00 (50.8) 0.88 (22.2) 1.19 (30.1) 1.00 (25.4) 0.91 (23.0) 1.63 (41.3) OUT CYL 1/8 NPT 0.08 (2.0) ea. OUT CYL 1/8 NPT IN 3 places 1/4 NPT GLUE SUPPLY 1/8 NPT 1.59 (40.5) 2.25 (57.2) 4 places ø 0.22 (5.5) hole on base, sq. centers IN GLUE SUPPLY 1.75 (44.4) sq. 4 places ø 0.22 (5.5) hole on base,1.25 (31.7) sq. centers R561, R332C, R332 10/22/97 210 34B. 34C. 34CW. 34CH. 34T, 34F 10/22/97 232 RSR. SC1, CI, SQE, C125, S125 10/22/97 233 Technical Section 10/22/97 212 Technical Section 10/22/97 213 Technical Section 10/22/97 214 Technical Section 10/22/97 215 Technical Section 10/22/97 216 Technical Section 10/22/97 217 Technical Section 10/22/97 218 Technical Section 10/22/97 219 2P/3P 10-32 UNF 1/8 NPT 4P 1.45 (36.9) 0.39 0.48 (9.9) (12.2) ø 0.44 (11.1) CYL 0.33 0.33 (8.4) (8.4) ø 0.66 (16.8) EXH 0.56 hex 47-32 (14.2) (11.9) EXH CYL N/C IN 4PP 2.25 1.86 (57.2) (47.2) 0.33 0.36 0.33(8.4) 0.36 0.48 (9.1) 0.48 (8.4) (9.1) (12.2) (12.2) ø 0.44 ø 0.44ø 0.66 ø 0.66 E E E (11.1) ø 0.66 (11.1) (16.8) (16.8) CYL X X CYL CYL X IN (16.8) H H N/O H 10-32 UNF 2 places 47-32(11.9) 47-32(11.9) 10-32 UNF 2 places 47-32 (11.9) 0.59 (15.1) 0.36 (9.1) 1.25 (31.8) 47-32 (11.9) 0.31 (7.9) 0.96 (24.4) ø .19 (4.8) 2 places 2P, 4P, 4PPX, 3P, 31P, 31PPX, 41P, 41PP, 41PPX, 43P, 43PP, 43PA 10/22/97 47-32 (11.9) 0.84 (21.3) 0.28(7.1) CYL ø .19 (4.8) 2 places 0.36(9.1) 0.84 (21.3) EXH CYL IN N/C 10-32 UNF 2 places CYL N/O E X ø 0.44 ø 0.66 (11.1) (16.8) H 47-32(11.9) 41P/41PP 0.62 (15.8) 31PPX EXH IN 0.33 (8.4)CYL 0.33 (8.4) 0.48 (12.2) NC 0.28 (7.1) 0.38 1.31 NO (9.7) (33.3) 2.18 (55.5) 0.33 0.33 (8.4) (8.4) 1.25 (31.8) 31PPX 31P ø 0.44(11.1) 47-32 (11.9) 4PPX 1.31 (33.3) 0.67 (17.0) 0.36 (9.1) ø 0.44 (11.1) 47-32 (11.9) 1/8 NPT 3 places ø 0.44 (11.1) 47-32 0.48 (11.9) 0.31 (12.2) (7.9) 0.33 EXH 0.83(8.4) C1 0.52 (21.1) (13.2) 3.31 (84.1) C2 ø .19(4.8) EXH 10-32 UNF 3 Places 41 PP 0.34 All dim. Only 1.25(8.6) typical (31.8) 220 1.25 (31.8) 0.62 (15.8) 41PPX 47-32 (11.9) 0.32 (8.1) IN 41PPX 0.31 (7.9) 0.84 (21.3) 0.50 (12.7) 1.65 (41.9) 1.15 0.31 (29.2) (7.9) 0.34 (8.6) C2 EXH 10-32 UNF 0.34 (8.6) C1 EXH 0.82 (20.8) 1.34 (34.0) 1/8 NPT 3 places ø 0.66 (16.8) ø 0.44 (11.1) 2P, 4P, 4PPX, 3P, 31P, 31PPX, 41P, 41PP, 41PPX, 43P, 43PP, 43PA 10/22/97 221 10-32 pilot port 0.47 0.56 (11.9) (14.3) hex 0.47 (11.9) 0.81(20.6) hex 1/8 NPT pilot port ø 0.86 (21.8) 1.25 (31.8) ø 0.56 (14.3) 2.34 (59 5) 34A ENG 341A ENG 0.47 (11.9) 1/8 NPT pilot port ø 0.63 (15.9) 1.38 (34.9) 0.56 (14.3) hex 34A, 341A, 34AS, 341AS, 34AR, 341AR, 34ASR, 341ASR 10/22/97 341AR ENG 0.47 (11.9) 0.81(20.6) hex 1/8 NPT pilot port ø 0.86 (21.8) 2.44 (61.9) 222 34A, 341A, 34AS, 341AS, 34AR, 341AR, 34ASR, 341ASR 10/22/97 223 0.555 (0.022) 0.407 0.156 (0.016) (0.006) ball diameter: 0.437 (0.017) A 0.538 (0.021) 0.56 (14.3) hex 34CW ENG .16 (4.0) wide 1.09 (27.8) .19 (4.8) 1.19(30.2 max. pawl (25.4) folded 1.00 back min. .07 (1.9) 0.78(19.8) .27 (6.7) mount 8-600 etc. .50 (12.7) 0.020 (0.001) A adjustable 34C ENG 0.27 (6.7) 1.09 (27.8) 0.19 (4.8) 0.94 (23.8)max. 0.75(19.1)min. 0.07 (1.9) mount nylon roller 8-600 etc. 0.50 0.19 0.50 (12.7)x (4.8) wide (12.7) ø 0.75 (19.1) CAM. HEAVY DUTY x 0.25 (6.4) deep LESS CAM ROLLER ø 0.20 (5.2) 0.47 34CH ENG TYP. [4] (11.9) 1.50 0.28 0.73 (38.1) 0.06 (18.6) (7.1) (1.6) 1.20 0.61 (30.6) (15.5) (28-60A) 0.39 CAM ROLLER (9.9) SEPERATE ORDER 0.83 (21.0) SLUG COLLAR TAC or TAC2 SLUG 34B. 34C. 34CW. 34CH. 34T, 34F 10/22/97 COLLAR CCW CW CCW CW 224 34T ENG 1.63 (41.3) 0.44 (11.1) (34C) 1.13 (28.6) [34T] 34F ENG 2.69 (68.3) 0.63 (15.9) 3.44 (87.3) 2.25 (57.2) 34B. 34C. 34CW. 34CH. 34T, 34F 10/22/97 1.56 (39.7) mount 8-600 ETC. 0.38 max. (9.5) 0.25 min. (6.4) 0.07 (1.8) 225 31V O 0.81 (20.6) 80 4V 0.81 (20.6) 2.13 (54.0) 0.36 (9.1) 80O 0.59 (15.0) 0.33 (8.4) CYL 1.31 (33.3) 0.33 (8.4) EXH EXH 0.28 (7.1) 0.38 (9.7) IN CYL 0.33(8.4) 80O 41V 0.36 (9.1) 0.33(8.4) CYL 1.25 (31.8) 0.81 (20.6) 2V/3V EXH 80O ø 0.66(16.8) EXH 0.83 C1 3.31(21.1) (84.1) 0.33 (8.4) 0.81 (20.6) 0.33 (8.3) 1.81 (46.0) 0.39 (9.9) CYL IN 0.31 (7.9) 0.52 (13.1) C2 EXH 0.56 Hex (14.3) 1/8 NPT 1/28/98 TACMOP 0.52 0.31(13.1) (7.9) IN 10-32 UNF 10-32 UNF 0.34 0.34 (8.6) (8.6) 1.25 (31.8) 226 0.38 (9.7) 41T O 80 0.78 (19.8) 0.48 (11.9) 1.13 (28.7) 0.77 (19.6) 5/8-32 Thd. B A O EXH O AU UB T 0.44 (11.2) T Hole size for panel mounting 0.66(16.8) x 1.25(31.8) 1.88 41R (47.8) 0.63 (16.0) 0.20 R Two places (5.2) speed nut #8-32 thd. 2 Places ø 0.22(5.6) 0.19 Typ. 1.22 (4.8) 1 (31.0) 3 2 0.05 0.44 (1.3) (11.1) IN 0.59 (15.0) A A 0.88 (22.4) 0.63 (16.0) 3 Places 1/8 NPT 1/28/98 TACMOP 2 Places ø 0.17(4.4) #8 screw B O EXH O U U T T B 1.42 (36.1) IN 227 1.38 (34.9) .88 (22.2) 8-60 .50 B (12.7) 1.38 (34.9) 1.72 (43.7) 8-70 .75 1.06 .66 (19.1) (27.0) (16.8) .38 (9.7) B 7.50 (190.5) 2.00 .48 (51.0)TYP.(12.3) TYP. Ø TYP. .19 1.00 (4.8) (25.4) 2.12 1.75 (54.0) (44.5) .69 (17.5) TYP. .34 (8.6) TYP. 8-600 .83 (21.0) 1.38 (34.9) .07 (1.9) A .73 (18.5) 1.95 (49.4) .41 (10.4) ø .44 (11.1) .56 HEX (14.3) 4 places 1.20 ø .15 .12(3.0) (30.5) (3.7) .25 .08 (2.0) (6.4) 1.00 TYP. (25.4) 8-55A ENG 1.87 (47.5) .61 .65 (15.4)(16.6) .70 (17.9) .88 .50 (22.2) (12.7) .15 (3.9) 8-60, 8-600, 8-55A, ESB SWITCH 10/23/97 ESB .69(17.5)2.38 (60.5) Ø TYP. .22 (5.6) 1.17 (29.8) .76 (19.3) 1.56 (39.6) 2 holes Ø .48 (12.3) .50(12.7) .25(6.4) 2 holes Ø .15 (4.0) .47 -32 THD x .28 LG (11.9) (7.1) Supplied With [2] Locknuts & [1] Lockwasher .78 (20.0) 1.00(25.4) .06 (1.6) 230 ø 0.75 (19.1) RSR 1.19 (30.2) Max. 0.94 (23.9) Min. 15/32-32 Thd. SC1 0.38 (9.7) OUT CYL 1.11 (28.2) 3.38 (85.9) Max. 3.13 (79.4) Min. .81 Hex (20.6) 0.88 (22.4) 0.44 Max (11.1) 0.56 (14.2) TAC SC1 0.88 (22.4) OUT 2 Places 10-32 UNF CON TROL 2 Places ø 0.19(4.8) ® KALAMAZOO, MICH. 1/8 NPT IN 10-32 UNF RSR. SC1, CI, SQE, C125, S125 10/22/97 228 0.69(17.5) 0.38 hex FLOW (9.5) C1 Check valve Model C1 Check valv4 has #10-32 male and female ports. Furnished with gasket for male thread. C125 ENG .88 (22.2) HUMPHERY C125 FLOW .88 .44 (22.2) (11.1) 1.75 (44.5) SQE S125 1.31(33.3) HUMPHREY S125 IN IN OUT ø .56 (14.3) RSR. SC1, CI, SQE, C125, S125 10/22/97 #10-32 UNF-2A x 0.16(4.1) deep both ends 0.94(23.9) 0.09 (2.3) 0.66(16.8) 0.20 Ø 0.28 (5.1) 0.16 (7.1) 0.38 ø 0.28 (7.1) #10-32 (4.1) Typ. (9.6) 0.47 UNF-2B (11.9) 0.38 (9.6) EXH IN IN OUT .50 (14.3) wrench flats 229 Miniature Fittings 10/23/97 231