Preview only show first 10 pages with watermark. For full document please download

Solid State Relay Ssr10

   EMBED


Share

Transcript

Solid State Relay SSR10 The SSR10 pin-out is compatible with standard OAC type I/O modules and all models are available with random turn-on as an alternative to zero cross turn-on. The SSR10 range offers choice of 240, 380 and 480VAC versions. Input voltage specifications have 3-15VDC and 15-32VDC. 240 and 380VAC models include an internal snubber T Input: DC control T Double SCR AC output or TRIAC AC output T Dielectric Strength: 4000VAC, 1min T Printed circuit board mount Options and ordering codes SSR10 - 3 Input voltage 3-15VDC 15-32VDC 3 15 240 Load Voltage 48-264VAC 48-400VAC 48-480VAC 5 R NIL S 240 380 480 Load Current 3 5 3A 5A R Z Input 3 15 3 15 3 to 15VDC 15 to 32VDC Max. 3VDC Max. 15VDC Min. 1.0VDC Characteristics Dielectric strength (input to output) Insulation resistance Vibration Humidity Weight SSR10/07/07 Output Type TRIAC SCR Zero Cross Function Random turn-on Zero Cross turn-on Output Input voltage Input voltage Must operate voltage Must operate voltage Must release voltage Ambient temperature S Operating Storage 4000VAC 1min. 50/60Hz 1 min. 1000MΩ min (at 500VDC) Double range 1.5mm 10 to 55Hz -30˚C to +80˚C -30˚C to +100˚C 45% to 85% Max. 15g Large voltage range (at 47 to 63Hz) 240VAC 380VAC 480VAC Load current range Max. Surge current (10ms) Max. off-state leakage current (at rated voltage) Max. On-state voltage drop Zero-cross Max. Turn on time Random Max .Turn-off time 240VAC Transient overvoltage 380VAC 480VAC Min. Off-state dv/dt Min. Power factor 48 to 264VAC 48 to 400VAC 48 to 480VAC 0.1 to 5A Triac output 10 times rated current SCR output: 250Apk 1.5mA 1.5V ⁄2 cycle + 1ms 1 ⁄2 cycle + 1ms 10ms Max. 600Vpk Max. 800Vpk Max. 1200Vpk 200V/µs 0.5 1 www.imopc.com Solid State Relay SSR10 Outline dimensions (mm) Wiring diagram and PC Mounting Holes 43.1± 0.6 2.54 4-Ø1.2 25.4 2.54 0.5 7.0± 0.5 5.1± 0.15 7.6 0.3 2.0± 0.15 17.8± 0.4 1.3± 0.1 1.0 ± 0.1 27.9± 0.5 1 2 -4 +3 Load Input control Power supply Characteristic Curve MAX. LOAD CURRENT VS. AMBIENT TEMPERATURE. 5A TYPE 6 6 5 5 Load Current (A) Load Current (A) MAX. LOAD CURRENT VS. AMBIENT TEMPERATURE. 3A TYPE 4 3 2 4 3 2 1.5 1.5 1 1 0 -30 -20 0 20 30 40 60 80 0 -30 -20 100 Ambient Temperature (°C) 20 25 60 40 80 100 MAX. PERMISSIBLE NON-REPETITIVE PEAK SURGE CURRENT VS. NUMBER OF CYCLES (SCR OUTPUT) 1200 300 IT 0 1000 ITSM Peak Surge Current (A) Peak Surge Current / Rated Current (%) MAX. PERMISSIBLE NON-REPETITIVE PEAK SURGE CURRENT VS. NUMBER OF CYCLES (TRIAC OUTPUT) time T Tj initial = 25°C max. 800 600 400 200 IT 0 250 ITSM time T Tj initial = 25°C max. 200 150 100 50 0 0 1 10 100 Number of cycles (at 50Hz) SSR10/07/07 0 Ambient Temperature (°C) 1000 1 10 100 1000 Number of cycles (at 50Hz) www.imopc.com