DIGITAL I/O MODULES 17.5mm DIN-RAIL OUTPUT MODULES FEATURES: UL and cUL (E46203) Recognized CE Compliant DIN-Rail Mountable (17.5mm wide) Single Point Output Modules AC Output Rating 5 Amp at 12 to 280 VAC, with 350 Amp Single Cycle Surge Capability DC Output Rating 3 Amp at 5 to 60 VDC 4 to 32 VDC Input Current regulated Zero Voltage Turn-on for AC Module 4 kV Optical Isolation with LED Indicator Barrier Strips Accept 14 to 28 AWG Wire Configured for Panel Mounting
OUTPUT SPECIFICATIONS: (1) Model Number Parameter Nominal Line Voltage Minimim Line Voltage Maximum Line Voltage Max Off-State Voltage (3) Max Off-State Leakage (4) Static Off-State dv/dt (5) Maximum Rated On-State Current (6) Min On-State Current Max Surge Current (7) On-State Voltage Drop (8)
INPUT SPECIFICATIONS: (1)
84130105 84130108
84130104
120/240 VAC 12 VAC 280 VAC 800 Vpeak .1 mA 50 V / µ sec
5-60 VDC 5 VDC 60 VDC 60 VDC 10 µA N/A
5.0 Arms 50 mArms 350 Apeak 1.85 Vpeak
3.0 A 10 mA 5.0 A 1.6 VDC
84130104 84130105 84130108
Model Number Parameter Nominal Voltage Minimum Voltage Maximum Voltage Drop-Out Voltage Maximum Current (2) Resistance
4-32 VDC 4 VDC 32 VDC 1 VDC 22 mA Current Regulated
GENERAL SPECIFICATIONS: (1) Model Number Parameter Operating Temperature Range Storage Temperature Range Maximum Turn-on Time (9) (11) Maximum Turn-off Time (9) Input/Output Isolation Voltage (10) Input/Output Capacitance (typical) Line Frequency Range
DIMENSIONS: 17.50 (0.689)
3
2
4
1
Units °C °C mSec mSec VAC pF Hertz
84130105 84130108 -30 to 80 -40 to 100 8.33 8.33 4000 6 47 to 63
84130104 -30 to 80 -40 to 100 0.05 0.05 4000 4 DC
Notes: (1) Specifications apply to an ambient temperature of -30 to 80°C unless otherwise noted. (2) Modules are current limited +/-10% at 25°C . (3) Maximum 1 minute duration for OAC modules when applied as a DC voltage rather than peak AC voltage. (4) At maximum line voltage, 25°C for OAC modules, and 80°C for ODC modules. (5) Minimum dv/dt per EIA/NARM RS443, method RS397. dv/dt ratings do not apply to ODC modules. (6) At 25°C, derate 84130105 modules by 46.9 mA/°C to 80°C; derate 84130104 modules by 21.5 mA/°C to 80°C. (7) At 25°C. Maximum duration: 1 AC cycle for OAC modules, 1 second for ODC modules. (8) At maximum rated on-state current and 25°C. (9) At maximum line voltage, maximum rated output current, nominal input voltage, 25°C. Switching speed of OAC modules based upon 60 Hz line frequency. (10) At 25°C for 1 second maximum duration. DIN RAIL (11) For 84130108 turn-on time is 0.1 mSec. AC OUTPUT MODULE
81.00 (3.189) 18.00 (0.709) 45.00 (1.772)
DIN RAIL DC OUTPUT MODULE
49.50 (1.949)
65.00 (2.559)
2
1 +VDC
LOAD* (A)
2 –VDC
VAC 1 VAC VAC
SCREW TERMINALS
VACLO +VCC
REPLACEABLE 5A FUSE
LOAD* (B)
LOAD* (A)
SCREW TERMINALS
2
REPLACEABLE 5A FUSE
3
LED
LOAD* (B)
S N U B
ZERO VOLTAGE CIRCUIT
+VCC LOGIC SUPPLY 3
LED
Rc
AMPLIFIER
+VCC LOGIC SUPPLY
4 INPUT
4 INPUT *LOAD MAY BE WIRED IN LOCATION A OR B
DIMENSIONS: MILLIMETERS (INCHES) TOLERANCE: ±0.020 (±0.50)
40.65 (1.600)
*LOAD MAY BE WIRED IN LOCATION A OR B. DC INDUCTIVE LOADS MUST BE DIODE SUPRESSED TO PREVENT DAMAGE TO THE I/O MODULE.
(EQUIVALENT CIRCUIT DIAGRAMS)
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
2-33
SOLID STATE RELAYS 22.5mm DIN-RAIL SSR FEATURES:
DIN-Rail or panel mount. Compact Size. LED indicator. AC or DC control. Zero AC turn-on models. 12 and 25 Amp Outputs UL, cUL Recognized (25 Amp Model: UL Rating 20 Amps) 12 Amp .5 HP @ 240 VAC 20 Amp 1.5 HP @ 240 VAC CE Compliant Per EN60950 UL E79183
DIMENSIONS: inches (mm)
EQUIVALENT CIRCUIT CURRENT LIMITER
VISIBLE LED GREEN
1
5.15 (0.203) 4.50 (0.177)
OVER VOLTAGE PROTECTION
TRANSIENT PROTECTION
U
VOLTAGE DETECTOR
OVER VOLTAGE PROTECTION
OUTPUT
2
3OUTPUT
2
3
DC INPUT 22.5mm ZERO TURN-ON
43.85 [1.725]
11.25 (0.443)
4.50 (0.177)
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-4
102.80 [4.047]
6.80 [0.268]
84130101 SOLID STATE RELAY
9.00 (0.354)
87.70 (3.453)
1
4 +
SNUBBER NETWORK
CURRENT LIMITER
VISIBLE LED GREEN
4+
GORDOS
5.00 (0.197)
AC INPUT 22.5mm ZERO TURN-ON
1
97.80 (3.85)
INPUT
2
80.00 (3.150)
VOLTAGE DETECTOR
SNUBBER
TRANSIENT PROTECTION
U
3
-
22.50 (0.886) 5.24 (0.208)
4
SOLID STATE RELAYS 22.5mm DIN-RAIL SSR
1 INPUT SPECIFICATIONS: 84130101 84130103 84130116 4-32 VDC 1.0 VDC 12 8.33 8.33 Zero Crossing 0.00˝-.078˝
84130150 84130152 84130158 90-140 VAC 10 VAC 6 20 30 Zero Crossing 0.00˝-.078˝
84130100 84130102 84130118 180-280 VAC 10 VAC 6 20 30 Zero Crossing 0.00˝-.078˝
Model Number
84130100 84130101
84130102 84130103
Parameter Line Voltage Peak Off-State Voltage (2) Maximum Off-State Leakage (3) Static Off-State dv/dt (4) Minimum On-State Current Maximum On-State Current (5) Maximum 1-Cycle Surge (6) Maximum 1-Second Surge (7) Peak On-State Voltage Drop (8) l2t (60 Hz, Half-Cycle) Output Type Wire Size
84130150 24-280 600 .1 200 100 12 250 60 1.85 260 TRIAC 0.20˝-.078˝
84130152 24-280 800 .1 600 100 20 400 140 1.8 600 ALTERNISTOR 0.20˝-.078˝
84130116 84130117 84130118 84130158 48-660 1200 .25 500 100 25 250 75 1.6 260 B/B SCR 0.20˝-.078˝
Model Number Parameter Control Voltage Drop Out Voltage Maximum Input Current (1) Maximum Turn-On Time Maximum Turn-Off Time Type Wire Size
84130117 Units 4-32 VDC 1.0 VDC 12 0.1 8.33 Random Turn-on 0.00˝-.078˝
mA ms ms
OUTPUT SPECIFICATIONS:
Units Vms Vpeak mArms V/Sec mArms Arms Apeak Apeak Vpeak A2 sec
GENERAL SPECIFICATIONS: Parameter Operating Temperature Range Storage Temperature Range Input to Output Isolation Voltage (9) Input/Output to Ground Isolation Voltage (9) Capacitance (Input to Output) Line Frequency Range
All Devices -20 to 80°C -40 to 100°C 4000 Vrms 2500 Vrms 8 pF 47 to 63 Hz
Notes: (1) At maximum input voltage. Input is regulated and current limited. (2) Do not apply continuously for over 1 minute. (3) At maximum line voltage, Ta = 25°C. (4) Minimum dv/dt per EIA/NARM R5443, method RS397, 25°C. (5) Mounted in vertical position on DIN-Rail. Free Air. (6) Non-repetitive 60 Hz, resistive load, Ta = 25°C. (7) Non-repetitive 50 or 60 Hz, resistive load, Ta = 25°C. (8) At maximum rated current. (9) Limited to 1 mA for 1 second, Ta = 25°C.
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-5
SOLID STATE RELAYS 45mm DIN-RAIL SSR FEATURES:
DIN-Rail or Panel Mount. Compact Size. LED Indicator. AC or DC Control. Zero AC or Random turn-on models. 35 and 45 Amp Outputs. 4 kV Optical Isolation. CE Compliant Per EN60950 UL, cUL Recognized E79183
45.00 (1.772) 3.20 (0.126) 35.70 (1.406) 12.20 (0.480) CURRENT LIMITER
1
VISIBLE LED
4
5.00 (0.197)
3
AC 45mm THREE PHASE
2
9.00 (0.354)
INPUT 4-32 VDC + 4
AC INPUT EQUIVALENT CIRCUIT
CURRENT LIMITER
OUTPUT 35 AMPS 48 TO 530 VAC
80.00 (3.150)
2
88.00 (3.858)
84130111 SOLID STATE RELAY
87.70 (3.453)
PROTECTION
OVER VOLTAGE PROTECTION
SNUBBER
GORDOS
1
3
9.30 (0.366)
1
VISIBLE LED
2
102.80 [4.047]
SNUBBER
OVER VOLTAGE PROTECTION
6.80 [0.268]
PROTECTION
4
3
DC 45mm THREE PHASE RANDOM
DC INPUT EQUIVALENT CIRCUIT
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-6
SOLID STATE RELAYS INPUT SPECIFICATIONS: Model Number Parameter
84130111 84130113
84130112 84130114
84130110 84130115
Control Voltage Drop Out Voltage Maximum Input Current (1) Maximum Turn-On Time Maximum Turn-Off Time Type Wire Size
4-32 VDC 1.0 VDC 10 8.33 8.33 Zero Crossing .020˝-.078˝
4-32 VDC 1.0 VDC 10 0.1 8.33 Random Turn-on .020˝-.078˝
90-280 VAC 10 VAC 6 20 30 Zero Crossing .020˝-.078˝
1
Units mA ms ms
OUTPUT SPECIFICATIONS: Model Number
84130110 84130111 84130112
84130113 84130114 84130115
48-530 1200 .25 500 100 35 750 145 1.6 1000 .040˝-.220˝
48-530 1200 .25 500 100 45 750 145 1.6 1000 .040˝-.220˝
Parameter Line Voltage Peak Off-State Voltage (2) Maximum Off-State Leakage (3) Static Off-State dv/dt (4) Minimum On-State Current Maximum On-State Current (5) Maximum 1-Cycle Surge (6) Maximum 1-Second Surge (7) Peak On-State Voltage Drop (8) I2t (60Hz, Half-Cycle) Wire Size
Units Vrms Vpeak mArms V/Sec mArms Arms Apeak Apeak Vpeak A2 sec
GENERAL SPECIFICATIONS: Parameter
All Devices
Operating Temperature Range Storage Temperature Range Input to Output Isolation Voltage (9) I/O to Ground Isolation Voltage (9) Capacitance (Input to Output) Line Frequency Range
-20 to 80°C -40 to 100°C 4000 Vrms 2500 Vrms 8 pF 47 to 63 Hz
Notes: (1) (2) (3) (4) (5) (6) (7) (8) (9)
At maximum input voltage. Input is regulated and current limited. Do not apply continuously for over 1 minute. At maximum line voltage, Ta = 25°C. Minimum dv/dt per EIA/NARM R5443, method RS397, 25°C. Mounted in vertical position on DIN-Rail. Free Air. Non-repetitive 60 Hz, resistive load, Ta = 25°C. Non-repetitive 50 or 60 Hz, resistive load, Ta = 25°C. At maximum rated current. Limited to 1 mA for 1 second, Ta = 25°C.
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-7
SOLID STATE RELAYS 90mm 2 and 3 PHASE DIN-RAIL SSR
FEATURES:
DIN-Rail or panel mount. Compact Size. LED indicator. AC or DC control. Zero AC or random turn-on models. 4 kV optical isolation. UL, cUL Recognized (File E79183) CE Compliant Per EN60950
90.00 (3.543) 80.70 (3.177)
S/L2
R/L1
97.20 (3.827)
4.50 (0.177)
T/L3 87.70 (3.827)
87.70 (3.827)
84130310 SOLID STATE RELAY
OUTPUT: 25 OUTPUT: 20 AMPS AMPS 48660 VAC 48-660 VAC U/T1
98.00 (3.858)
GORDOS
GRD
V/T2
V/T1
+ A2
A1
DIMENSIONS: inches (mm) TOLERANCE: ±0.20 (±0.008)
9.30 (0.366)
CURRENT CURRENT LIMITER LIMITER
VISIBLE LED VISIBLE LED GREEN GREEN
U/T1 U/T1
VISIBLE LED VISIBLE LED GREEN GREEN
U/ T1 U/T1
A1
VOLTAGE VOLTAGE DETECTOR DETECTOR
VOLTAGE VOLTAGE DETECTOR DETECTOR
SNUBBER SNUBBER
U
OVER OVER VOLTAGE VOLTAGE PROTECTION PROTECTION
OVER OVER VOLTAGE VOLTAGE PROTECTION PROTECTION
SNUBBER
U
CURRENT CURRENT LIMITER LIMITER
SNUBBER
A1
R/L1 R/L1 V/T2 V/T2
U
VOLTAGE VOLTAGE DETECTOR DETECTOR
SNUBBER SNUBBER
TRANSIENT TRANSIENT PROTECTION PROTECTION
OVER OVER VOLTAGE VOLTAGE PROTECTION PROTECTION
U
INPUT VOLTAGE VOLTAGE DETECTOR DETECTOR
U/T1 U/T1
SNUBBER
V/T2 V/T2
SNUBBER
TRANSIENT TRANSIENT PROTECTION PROTECTION
R/L1 R/L1
OUTPUT
OVER OVER VOLTAGE VOLTAGE PROTECTION PROTECTION
S/L2 S/L2 W/T3 W/T3
S/L2 S/L2
VOLTAGE VOLTAGE DETECTOR DETECTOR
OVER OVER VOLTAGE VOLTAGE PROTECTION
VOLTAGE VOLTAGE DETECTOR DETECTOR
T/L3 T/L3
A2
PROTECTION
T/L3 T/L3
A2
3 PHASE 90mm DC INPUT ZERO CROSSING OR RANDOM
3 PHASE 90mm DC INPUT
OVER OVER VOLTAGE VOLTAGE PROTECTION PROTECTION
SNUBBER
SNUBBER SNUBBER
U U
SNUBBER
W/T3 W/T3
3 PHASE 90mm AC INPUT ZERO CROSSING
3 PHASE 90mm AC INPUT ZERO CROSSING NOTE: V/T2 to S/L2 is shorted on 2 phase models.
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-8
SOLID STATE RELAYS 90mm 2 and 3 PHASE DIN-RAIL SSR
1 INPUT SPECIFICATIONS: Model Number Parameter Control Voltage Drop Out Voltage Maximum Input Current (1) Maximum Turn-On Time Maximum Turn-Off Time Type
OUTPUT SPECIFICATIONS: Model Number Parameter Line Voltage Peak Off-State Voltage (2) Maximum Off-State Leakage (3) Static Off-State dv/dt (4) Minimum On-State Current Maximum On-State Current per phase (5) Maximum 1-Cycle Surge (6) Maximum 1-Second Surge (7) Peak On-State Voltage Drop (8) l2t (60 Hz, Half-Cycle)
84130310 84130220 4-32 VDC 1.0 VDC 22 8.33 8.33 Zero Crossing
84130312 84130221 4-32 VDC 1.0 VDC 22 0.1 8.33 Random Turn-on
Three Phase 84130310 84130311 84130312
Two Phase 84130220 84130221 84130222
48-530 1200 .25 500 100 20 750 145 1.6 1000
48-530 1200 .25 500 100 25 750 145 1.6 1000
84130311 84130222 90-280 VAC 10 VAC 6 20 30 Zero Crossing
Units
mA ms ms
Units Vrms Vpeak mArms V/Sec mArms Arms Apeak Apeak Vpeak A2 sec
GENERAL SPECIFICATIONS: Parameter Operating Temperature Range Storage Temperature Range Input to Output Isolation Voltage (9) Input/Output to ground Isolation Voltage (9) Capacitance (Input to Output) Line Frequency Range
All Devices -20 to 80°C -40 to 100°C 4000 Vrms 2000 Vrms 8 pF 47 to 63 Hz
Notes: (1) At maximum input voltage. Input is regulated and current limited. (2) Do not apply continuously for over 1 minute. (3) At maximum line voltage, Ta = 25°C. (4) Minimum dv/dt per EIA/NARM R5443, method RS397, 25°C. (5) Mounted in vertical position on DIN-Rail. Free Air. Derated by 27.3 mA/°C to 80°C. (6) Non-repetitive 60 Hz, resistive load, Ta = 25°C. (7) Non-repetitive 50 or 60 Hz, resistive load, Ta = 25°C. (8) At maximum rated current. (9) Limited to 1 mA for 1 second, Ta = 25°C.
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-9
SOLID STATE RELAYS THREE-PHASE MOTOR REVERSING RELAYS Convenient Self-Contained Design Eases Installation and Wiring 24 to 600 VAC Output Voltage Range Suitable for Many Applications 1000 Volts Peak Blocking Voltage Helps Protect Against Transients in Harsh Electrical Environments 5000 VAC Isolation
3 to 32 Control Voltage for a Wide Variety of Logic Circuit Applications Compact Sealed Package with Screw Terminals Interlock Circuit Prevents Inadvertant Actuation of Both Directions UL and cUL Recognized E79183 CE Compliant
; L1 O V P
S N U B B E R
O V P
S N U B B E R
O V P
S N U B B E R
O V P
S N U B B E R
;U OUTPUT
INPUT
A1F + FORWARD
A2 –
CONSTANT CURRENT AND INTERLOCKING CIRCUIT
REVERSE A1R +
➝
OVER VOLTAGE PROTECTION
; L2
; UV
EQUIVALENT CIRCUIT 4.09 (104,0)
3.19 (81,0)
OUTPUT TERMINALS 4.0 mm (4)
2.4 (61,0) DIMENSIONS: INCHES (MILLIMETERS) TOLERANCE:+-0.020 ( +- 0,50) 1.6 (41,0)
0.3 (7,62) 0.82 (21,0) 1.87 (47,6) L1
0.88 (22,6)
U
Y
L2
0.2 (5,3) 2.89 (73,5)
0.73 (18,5)
V
A1F
A2
A1R
0.47 (12,1) 0.25 (6,35) INPUT TERMINALS 3.5 mm (3)
3.62 (92,0)
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-22
SOLID STATE RELAYS THREE-PHASE MOTOR REVERSING RELAYS
1
INPUT SPECIFICATIONS: (1) MODEL NUMBER Parameter Voltage Range Drop Out Voltage Control Current (2)
GA012D25 GA012D40 3.0 to 32 1.0 25
Units VDC VDC mA
GA012D25
GA012D40
24 to 660 1200 25 0.2 .25 270 365 1.6 500
24 to 660 1200 40 0.2 .25 450 1000 1.6 500
OUTPUT SPECIFICATIONS: (1) MODEL NUMBER Parameter Line Voltage Range Maximum Peak Off-State Voltage (3) Rated Current (4) Minimum Current Maximum Off-State Leakage (5) One Cycle Surge Current (6) l2t Fusing Current Maximum On-State Voltage Drop (7) Off-State dv/dt (8)
Units VAC Vpeak Arms Arms mArms Apeak A Seconds Volts peak V/Sec
GENERAL SPECIFICATIONS: (1) Parameter Operating Temperature Range Storage Temperature Range Maximum Turn-on Time (9) Maximum Turn-off Time (10) Input/Output Isolation (11) Input/Output to Base Isolation (11) Input/Output Capacitance (typical) Line Frequency Range Weight Interlocking Time
All Devices -30 to 80°C -40 to 100°C 150 ms 1/2 cycle 4000 VAC 2500 VAC 8 pF 47 to 63 Hz 455 grams 100 mSec
GAO THERMAL DISSIPATION CURVES
THERMAL DISSIPATION 25 AMP GAO SERIES (ALL)
5°
50
1°
C/
W
80
C/
W
40
90 2° C
/W
30
100
3° C/W
20
110
10
120
NO HEATSINK
0
5 10 15 ON-STATE CURRENT (AMPS rms)
20
25
10
20
30
40
50
60
AMBIENT TEMPERATURE (°C)
70
80
BASEPLATE TEMPERATURE (°C)
POWER DISSIPATION (WATTS)
70 0.
Notes: (1) Specifications apply to each phase at an ambient temperature of -20 to 80°C unless otherwise noted. (2) Input is regulated and current limited. (3) Semiconductors rated at 1200 V. (4) See thermal dissipation/derating chart for heat sinking requirements. Catalog number PR250/100SE2 heat sink available separately for mounting GAO series SSR’s. (5) At maximum line voltage, 25°C. (6) One AC cycle maximum duration, non-repetitive, 25°C. (7) At rated output current, 25°C. (8) Minimum dv/dt per EIA/NARM RS443, method RS397, 25°C. (9) At minimum input voltage, maximum line voltage, rated output ourrent, 25°C. (10) At maximum input voltage, maximum line voltage, rated output current, 25°C. (11) At 25°C for 1 second maximum duration.
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-23
SOLID STATE RELAYS GA1, GA8, SERIES
High Current Thyristor for 100A Surge Capability UL Recognized/Horse Power Rated (GA8) (E46203) 4KV Optical Isolation
Zero Voltage Turn-On Industry Standard Packaging, SIP or Flat Pack Form A Output CE Compliant
GA1 0.15 (3,8)
0.15 (3,8)
2(OUTPUT)1
1.2 (30,5)
1.5 (38,2)
1.1 (27,9)
4 (INPUT) 3+ 0.3 (7,6)
0.8 (20,3) 0.04 (1.0) DIA. TYP. 1.4 (35,6)
0.25 (6,4)
4
3
2
1
1.0 (25,4)
0.035 (,89)
0.245 (6,2)
0.375 (9,5)
GA8 DIMENSIONS: inches (mm) TOLERANCE: ±0.020 (±0,50)
0.042 (1,1) DIA 1.7 (43,2)
TRIGGER CIRCUIT
0.3 (7,6) 0.7 (17,8)
1
+
SNUBBER
0.1 (2,5)
0.4 (10,2)
4
2
3
1.2 (30,5) 1.4 (35,5)
DIMENSIONS: inches (mm) TOLERANCE: ±0.020 (±0,50)
GA1 & GA8 SERIES DC INPUT EQUIVALENT CIRCUIT
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-18
SOLID STATE RELAYS GA1, GA8, SERIES
1
INPUT SPECIFICATIONS: (1) Parameter Minimum Turn-On Voltage Maximum Input Voltage Drop Out Voltage Maximum Input Current (2) Nominal Input Resistance (3)
GA16B02 GA86B02 3.0 28 1.0 25 1K
GA86D05 GA86D05R 3.0 28 1.0 25 1K
Units VDC VDC VDC mADC
GA16B02 (10) GA86B02
GA86D05 GA86D05R
Units
240 24 280 ±600 200
240 24 280 ±600 200
Vrms Vrms Vrms Vpeak V/S
GA16B02 GA86B02 4.0 .05 100 1.6
GA86D05 GA86D05R 5.0 .05 100 1.6
Units Arms Arms Apeak Vpeak
.1 1/4
.1 1/4
mArms H.P.
All Devices -30 to +80 -40 to +100 .5 4000 8 47 to 63
Units °C °C Cycle Vrms pF Hz
OUTPUT SPECIFICATIONS: Model Number Parameter Nominal Line Voltage Minimum Line Voltage Maximum Line Voltage Maximum Peak Off-State Voltage(4) Static (Off-State) dv/dt
Parameter Maximum On-State Current (5) Minimum On-State Current Maximum 1-Cycle Surge (6) On-State Voltage Drop (7) Maximum Off-State Leakage (8) 240V Models HP Rating (11)
GENERAL SPECIFICATION: (1) Parameter Operating Temperature Range Storage Temperature Range Response Time (12) Input to Output Isolation Voltage (9) Capacitance Input to Output (Typ) Line Frequency Range Note:
GA1-2B and GA1-4B have been replaced by GA1-6B GA8-2B and GA8-4B have been replaced by GA8-6B
10
5 AMP. GA8 DERATING CURVE
9 8
A rms
7 6 5 AMP.
Notes: (1) Specifications apply to Ta -30 TO +80 unless otherwise noted. (2) At maximum input voltage. (3) Does not include IRED impedance (drop). (4) One minute maximum duration when applied as a DC Voltage. (5) At Ta of 20°C, derate by 25 mA/°C to 40°C, 50 mA/°C from 40°C to 80°C. UL rating is 3.5 Arms, CSA rating is 3.0 Arms. (6) At Ta of 25°C, non-repetitive. (7) At Ta of 25°C and maximum on-state current. (8) At Ta of 25°C and maximum line voltage. (9) At Ta of 25°C, for one second. (10) Random turn-on versions available. Specify by adding suffix “R” to appropriate part number. Contact factory for additional details. (11) For GA8 only, 1/4 H.P. at 240 VAC, 1/8 HP at 120 VAC (12) AT 60 Hz 100 µS for Random Turn-on (suffix “R”) models
4 3 2 1 0 –30
–20
–10
0
10 20 30 40 50 TEMPERATURE DEGREE C
60
70
80
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-19
SOLID STATE RELAYS THREE-PHASE SOLID STATE RELAYS 10, 25 and 45 Amps Output Per Channel Available 24 to 600 VAC Output Voltage Range Suitable for Many Applications 1200 Volts Peak Blocking Voltage Helps Protect Against Transients in Harsh Electrical Environments Internal RC Snubber Network
4000 VAC Optical Isolation 4 to 32 Control Voltage for a Wide Variety of Logic Circuit Applications Zero Voltage or Random Turn-on Industry Standard Package UL Recognized (E74183) 10 hp 480 VAC, CSA Certified (LR38545) CE Compliant
CURRENT LIMITER
1
A1+ U ZERO VOLTAGE DETECTOR
OVER VOLTAGE PROTECTION
S N U B B E R
U ZERO VOLTAGE DETECTOR
OVER VOLTAGE PROTECTION
S N U B B E R
4 5 U ZERO VOLTAGE DETECTOR
A2–
OVER VOLTAGE PROTECTION
OUTPUT
INPUT
2 3
S N U B B E R
6
DIMENSIONS: INCHES (MILLIMETERS) TOLERANCE:+-0.020 ( +- 0,50)
0.73 (18,5)
0.88 (22,6)
OUTPUT TERMINALS 4.0 mm (6)
4.09 (104,0)
0.3 (7,62)
– +
4
6
1
3
5
2.89 (73,5)
A2
0.2 (5,3)
A1
1.87 (47,6) 2
INPUT TERMINALS 3.5 mm (2) 0.47 (12,1) 0.25 (6,35) 3.62 (92,0)
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-20
SOLID STATE RELAYS THREE-PHASE SOLID STATE RELAYS
1
INPUT SPECIFICATIONS: (1) Model Number
GA312D10R GA312D10Z GA312D25R
Parameter Voltage Range Drop Out Voltage Control Current (2)
GA312D25Z GA312D45R GA312D45Z
4.0 to 32.0 VDC 1.0 VDC 20 mA
GA312A25R GA312A25Z GA312A45R GA312A45Z 90-280 VAC 10 VAC 10 mA
OUTPUT SPECIFICATIONS: (1) Model Number
GA312D10R GA312D10Z
GA312A25R GA312A25Z GA312D25R GA312D25Z
GA312A45R GA312A45Z GA312D45R GA312D45Z
Parameter Line Voltage Range SSR Maximum Peak Off-State Voltage (3) Rated Current (4) Minimum Current Maximum Off-State Leakage (5) One Cycle Surge Current (6) l2t Fusing Current Maximum On-State Voltage Drop (7) Off-State dv/dt (8)
24 to 660 1200 10 0.2 10.0 160 128 1.6 500
24 to 660 1200 25 0.2 10.0 270 365 1.6 500
24 to 660 1200 45 0.2 10.0 450 1000 1.6 500
GA312D10R GA312D25R GA312D45R
GA312D10Z GA312D25Z GA312D45Z
GA312A25R GA312A25Z GA312A45R GA312A45Z
-30 to 80°C -40 to 100°C .20 8.33 4000 4000 8 47 to 63 450
-30 to 80°C -40 to 100°C 8.33 8.33 4000 4000 8 47 to 63 450
-30 to 80°C -40 to 100°C 20 30 4000 4000 8 47-63 450
Units VAC Vpeak Arms Arms mArms Apeak A2 Seconds Volts V/Sec
GENERAL SPECIFICATIONS: (1)
Parameter Operating Temperature Range Storage Temperature Range Maximum Turn-on Time (9) Maximum Turn-off Time (10) Input/Output Isolation (11) Input/Output to Base Isolation (11) Input/Output Capacitance (typical) Line Frequency Range Weight
GA3 SERIES 3 PHASE SOLID STATE RELAY PART NUMBER SELECTION GUIDE OUTPUT RATING FUNCTION
10A
25A
45A
GA312D10R
GA312A25R
GA312A45R
GA312D25R
GA312D45R
Random Turn-on Zero Voltage Turn-on
GA312D10Z
GA312A25Z
GA312A45Z
GA312D25Z
GA312D45Z
UNITS °C °C mSec mSec VAC VAC pF Hz g
Notes: (1) Specifications apply to each phase at an ambient temperature of -20 to 80°C unless otherwise noted. (2) Input is regulated and current limited. (3) 1000 V peak with Transorb® protection. Applying 1000V or greater will increase the off-state leakage and may result in relay failure if applied for longer than 1 second. (4) See thermal dissipation/derating chart for heat sinking requirements. Catalog number HS-7 heat sink available separately for mounting GA3 series SSR’s. (5) At 480 VAC line voltage, 25°C. (6) One AC cycle maximum duration, non-repetitive, 25°C. (7) At rated output current, 25°C. (8) Minimum dv/dt per EIA/NARM RS443, method RS397, 25°C. (9) At minimum input voltage, maximum line voltage, rated output ourrent, 25°C. (10) At maximum input voltage, maximum line voltage, rated output current, 25°C. (11) At 25°C for 1 second maximum duration.
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-21
SOLID STATE RELAYS GZ SERIES SSR FEATURES:
12 & 20 Amp AC Output Relays Low Profile Package Economical Triac Output 4000 VAC Optical Isolation Zero Crossing or Random Turn-On UL/cUL Recognized E46203
DIMENSIONS:
DERATE CURVES: LOW CURRENT STANDARD GZ SSRs 12 AMP 12.0 11.5 11.0 10.5
Load Current (Amperes)
10.0 9.5 9.0
HEAT SINK RATINGS:
8.5
0.5°C/W 0.7°C/W 1.0°C/W 1.5°C/W 2.0°C/W
8.0 7.5 7.0 6.5 6.0 5.5 5.0 20
25
30
35
40
45
50
55
60
65
70
75
80
Ambient Temperature (°C)
DERATE CURVES: HIGH CURRENT STANDARD GZ SSRs 20 AMP 20.0 19.0 18.0
WIRING:
17.0 16.0
1
4 TRIGGER
HEAT SINK RATINGS:
14.0 13.0
0.5°C/W 0.7°C/W 1.0°C/W 1.5°C/W 2.0°C/W
12.0 11.0 10.0
CIRCUIT
SNUBBER
Load Current (Amperes)
15.0
+ 3
2 Rc
GZ SERIES DC INPUT EQUIVALENT CIRCUIT
9.0 8.0 7.0 6.0 -20
-15
-10
-5
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
Ambient Temperature (°C)
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-24
SOLID STATE RELAYS GZ SERIES SSR
1 INPUT SPECIFICATIONS:
Model Number Parameter Control Voltage Drop Out Voltage Maximum Input Current (1) Maximum Turn-On Time Maximum Turn-Off Time Type Wire Size
84132000 84132010 84132400(9) 84132410(9)
84132100 84132110 84132500 84132510
4-15 1.0 32 8.33 8.33 Zero Crossing
4-15 1.0 32 0.1 8.33 Random Turn-On
Units VDC VDC mA ms ms
OUTPUT SPECIFICATIONS: Model Number Parameter Line Voltage Peak Off-State Voltage (2) Maximum Off-State Leakage (3) Static Off-State dv/dt Minimum On-State Current Maximum On-State Current (4) Maximum 1-Cycle Surge (5) Maximum 1-Second Surge (6) Peak On-State Voltage Drop (7) l2t (60 Hz, Half-Cycle) Rjb
84132000 84132100
84132010 84132110
84132400 84132500
84132410 84132510
24-280 600 0.1 250 0.1 12 120 36 1.65 50 3.0
24-280 600 0.1 250 0.1 20 200 60 1.55 50 2.2
36-530 800 0.1 250 0.1 12 120 36 1.65 50 3.0
36-530 800 0.1 250 0.1 20 200 60 1.55 50 2.2
Units Vrms Vpeak mArms V/Sec Arms Arms Apeak Apeak Vpeak A2 sec °C/W
GENERAL SPECIFICATIONS: Parameter Operating Temperature Range Storage Temperature Range Input to Output Isolation Voltage (8) I/O to Ground Isolation Voltage (8) Capacitance (Input to Output) Line Frequency Range
All Devices -20 to 80°C -40 to 100°C 4000 Vrms 2500 Vrms 8 pF 47 to 63 Hz
Notes: (1) At 15Vdc. (2) Do not apply continuously for over 1 minute. (3) At maximum rated voltage. (4) Mounted in free air, Ta = 45°C. (5) Non-repetitive 60 Hz, Resistive load, Ta = 25°C. (6) Non-repetitive 50 or 60 Hz, Resistive load, Ta = 25°C. (7) At maximum rated current. (8) Limited to 1 mA for 1 second, Ta = 25°C. (9) Input current is 63 mA Max.
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-25
SOLID STATE RELAYS HS10 HEATSINK
1
2.362
ORDERING INFORMATION: Model # HS10
Description Heatsink 1.1°C/W (For Single Phase SSR’s)
HS12 HEATSINK
ORDERING INFORMATION: Model # HS12
Description Heatsink 0.55°C/W (For Single Phase SSR’s)
DIMENSIONS: inches (mm) TOLERANCES: ±0.02 inches MATERIAL: AISI 6063-T5 Aluminum FINISH: Black Anodized
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-33
SOLID STATE RELAY ACCESSORIES HS1 HEATSINK
3.125 (79.38)
0.11 (2.8) DIA.
1.5 (38.1)
0.68 (17.5)
MOUNTING HOLES FOR 4MM SCREW (4)
3.875 (98.43)
DIMENSIONS: inches (mm) TOLERANCES: ±0.02 inches (±0.50)
ORDERING INFORMATION: Model # HS1
Description Heatsink 1.5°C/W (For GA0 & GA3 Series SSR’s)
5.625 (142.88)
HS2 HEATSINK
2.000
4.770
DIMENSIONS: inches TOLERANCES: ±0.02 inches MATERIAL: AISI 6063-T5 Aluminum FINISH: Black Anodized
4.450
ORDERING INFORMATION: Model # HS2
Description Heatsink 2.0°C/W (For Single Phase SSR’s)
0.201
2.000 3.00
0.50
0.16
#8-32 UNC
FOR #8-32 SCREWS 4 PLACES
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-28
SOLID STATE RELAY ACCESSORIES HS3 HEATSINK
1 2.625
4.750
0.50
0.201
3.00
4.430 0.16
2.000
DIMENSIONS: inches TOLERANCES: ±0.02 inches MATERIAL: AISI 6063-T5 Aluminum FINISH: Black Anodized
ORDERING INFORMATION: Model # HS3
Description Heatsink 1.5°C/W (For Single Phase SSR’s)
#8-32 UNC
FOR #8-32 SCREWS
HS13 HEATSINK
ORDERING INFORMATION: Model # HS13
Description Heatsink 0.8°C/W (For Single Phase and Three Phase SSR’s) DIMENSIONS: inches TOLERANCES: ±0.02 inches MATERIAL: AISI 6063-T5 Aluminum FINISH: Black Anodized
Products and specifications subject to change without notice.
Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1/31
SOLID STATE RELAY ACCESSORIES HS5 HEATSINK
2.630
4.750
DIMENSIONS: inches TOLERANCES: ±0.02 inches MATERIAL: AISI 6063-T5 Aluminum FINISH: Black Anodized
4.350
0.194
5.250 6.000
0.750
0.200
ORDERING INFORMATION: Model # HS5
Description Heatsink 0.7°C/W (For Single Phase SSR’s)
#8-32 UNC
HS6 HEATSINK
FOR #8-32 SCREWS 4 PLACES
6.250
6.250
Model # HS6
Description Heatsink 0.5°C/W (For Single Phase SSR’s)
1.00
0.201
ORDERING INFORMATION:
#8-32 UNC
6.00
6.050 0.10
4.000
DIMENSIONS: inches TOLERANCES: ±0.02 inches MATERIAL: AISI 6063-T5 Aluminum FINISH: Black Anodized
FOR #8-32 SCREWS 4 PLACES
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-30
SOLID STATE RELAYS HS7 HEATSINK
2.84 [72.0]
3.70 [94.0]
1
.0125 [3.2]
ORDERING INFORMATION: Model # HS7
4.094 [104.0]
Description Heatsink 0.9°C/W (For GA3 Series SSR’s)
3.307 [84.0] 7.87[200.0]
6.89[175.0]
5.90[150.0]
5.59[142.0]
4.92[125.0]
3.94[100.0]
2.95[75.0]
1.97[50.0]
0.98[25.0]
0.0[0.0]
3.465[88.0]
1.88[47.7] M4 X 0.7(16)PLACES
MOUNTING HOLE (4)
DIMENSIONS: inches (mm) TOLERANCES: ±0.02 inches MATERIAL: AISI 6063-T5 Aluminum FINISH: Black Anodized
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-31
SOLID STATE RELAYS HS8 HEATSINK
ORDERING INFORMATION: Model # HS8
Description Heatsink 2.1°C/W (For Single Phase SSR’s)
HS9 HEATSINK
ORDERING INFORMATION: Model # HS9
Description Heatsink 1.5°C/W (For Single Phase SSR’s)
DIMENSIONS: inches (mm) TOLERANCES: ±0.02 inches MATERIAL: AISI 6063-T5 Aluminum FINISH: Black Anodized Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-32
SOLID STATE RELAYS “SMART MODULE”
FEATURES: Supplies Electrical And Visual Feedback If An Error Occurs In The Circuit Or With The Host SSR 4 to 32 VDC Push-Pull Transistor Alarm Output 4000 VAC Optical Isolation 1200 VAC Peak Off-State Blocking Voltage Allows For Use With Any DC Input G & GA5 Series SSR UL/cUL Recognition Evaluation Pending Mounts On Any Standard Puck Style SSR
ELECTRICAL SPECIFICATIONS: (1)
LINE VOLTAGE:
INPUT: Nominal Voltage Maximum Voltage Minimum Voltage Off-State Voltage (2)
5-24 VDC 32 VDC 3 VDC 1 VDC
Line Voltage Off-State Blocking Voltage (6) Off-State Leakage Current (7)
DC SUPPLY/ERROR SIGNAL: Supply Voltage (3) Supply Current (4) Error Output Voltage (5) Error Output Current
24-660 Vrms 1200 Vpk 8 mArms
GENERAL SPECIFICATIONS: 4-32 VDC 15-30 mA 4-32 VDC 30 mA
Operating Temperature Storage Temperature Input To Output Isolation (8) Turn-On Time Turn-Off Time
-20° to +80°C -40° to +100°C 4000 Vrms 8.3 mSec 8.3 mSec
1.1 (27,9)
FUNCTION: (SMART MODULE ENERGIZED)
1.7 (43,2)
84060001 VDC IN
STATUS
INDICATOR
SSR OUTPUT
ERR
ERR OUT ON
OFF
ON
BLINKING
ON (GREEN LED)
NO INPUT TO SSR
INPUT POWER TO SSR
N/A
ERROR (RED LED)
NORMAL OPERATION
INTERNAL SHORT
EXTERNAL SHORT OR OPEN CIRCUIT
4-32VDC ERROR OUTPUT SIGNAL (DC SUPPLY)
0VDC (GROUND)
0VDC (GROUND)
1.0 (25,4) Notes: (1) Specifications apply to an ambient of -20° to + 80°C unless otherwise specified (2) Defined as the maximum allowable voltage on the input terminals of the SSR for the module to “sense” an off-state condition (3) Referenced to pin #4 (common) of the SSR (4) 30 mA max @ 32 VDC supply voltage; current regulated (5) During normal operation of the SSR; Error output = DC supply voltage (6) Maximum 1 minute duration (7) At maximum line voltage (8) At 25°C for 1 second
Ordering Information Part Number: 84060001
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-14
SOLID STATE RELAYS WIRING DIAGRAM:
1 Load
AC Line (24 - 660 Vac)
SOLID STA STATE RELAY RELAY Smartt Module Smar Error Output (2)
(4-32 Vdc)
DC Po Power Supply (2)
(4-32 Vdc)
Error Indicator Input Indicator
Input
(3-32 Vdc) (1)
Ground (2)
Note: Note: 1. G480D and G575D Series Series DC Input Range is 4-32 Vdc 1. HV GN Series DC Input Range is 4-32 Vdc 2. Input, Outputs and DC Po Power Supply 2. vInput, Outputs Supply oltages are refered refand eredDC to Power the same common Ground voltages are referred to the same common Ground
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-15
DC Solid State Relays GF Series; FET output - 10A, 15 A, 30A Very low leakage current (< 10uA) Milliohm On-Resistance Minimizes voltage drop, heat dissipation 1500 VAC Optical Isolation UL/cUL recognized, Tuv approved, CE compliant
IP20
GT Series; transistor output 10A Long Life Switching of DC loads 4 kV Optical Isolation UL E46203 Available with IP20 “touch-safe” cover
IP00
Output Specifications Output Voltage range VDC Off-state leakage mA Output Current (Mounted on proper heat sink, see deratings) Minimum Current Max. 1 second surge current Max On-State Voltage Drop or On-State Resistance m Ohms Rjb (thermal res. Junction to baseplate, ºC/W) Minimum hear sink @ ambient (for max current = ºC/W & Ta)
FET 1-200 0.01 10
FET 1-100 0.01 15
FET 1-50 0.01 30
TRAN 3-60 1.0 10
0.1 60 n/a 90 4.4
0.1 120 n/a 90 4.6
0.1 160 n/a 50 2.3
10 90 n/a n/a 4.3
3.0 @ 25ºc
3.0 @ 25ºC
1.0 @ 25ºC
1.0 @ 65ºC
Part Numbers FET Output Rating 10 Amp 15 Amp 30 Amp
Output 1-200Vdc 1-100Vdc 1-50Vdc
Input 3-32Vdc 3-32Vdc 3-32Vdc
IP00 84 134 850 84 134 860 84 134 870
IP20 84 137 850 84 137 860 84 137 870
3-32Vdc
84 134 750
84 137 750
Transistor Output 10 Amp
3-60Vdc
Input Specifications Input voltage* Drop out voltage Max. input current (mA) Min. input current (for on-state) m Input Resistance Max. Turn-on time (mS) Max. Turn-off time (uS)
20 12 2 50
3-32Vdc 1Vdc 20 20 12 12 Current Regulated 2 2 50 50
14.5 9 .1 200
General Characteristics Operating Temperature (°C) Storage Temperature (°C) Input to output isolation Input/output to ground isolation Input to output capacitance Housing Material
-20 to +80 -40 to +100 4000Vrms 2500Vrms 8pF (typical) UL 94V0 (self extinguishing)
Safety and Noise Immunity Compliance CE Compliant with the LVD 73/23/EEC TUV EN60950
1
4 CONTROL CIRCUIT 3
+
+
2
Rc GT SERIES EQUIVALENT CIRCUIT
DC inductive loads must be diode suppressed to prevent damage to SSR
1
4 CONTROL CIRCUIT
+ 3
+
CURRENT REGULATOR
2
GF SERIES EQUIVALENT CIRCUIT
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-16
Dual Solid State Relays
1
Output Specifications
Part Numbers
Voltage range (Vrms) Peak Voltage (Vpk, t = 1 min.) Off-state leakage mArms (@ max. line voltage & Ta = 25°C) Output Current (Mounted on proper heat sink, see deratings) Minimum Current (mArms) Max. 1 cycle surge current (Apk, Ta = 25°C) Max. 1 second surge current (Apk, Ta = 25°C) Forward voltage drop (Vpk @ Imax, Ta = 25°C) I2T (60Hz, 1/2 cycle) Rjb (thermal res. Junction to baseplate, °C/W) Static off-state dv/dt (Vµs, Ta = 25°C)
24 - 280Vac 550 0.1
24 - 280Vac 550 0.1
25
40
100 500
100 780
150
234
1.4
1.3
1041 0.6
2435 0.4
500
500
4-15Vdc 1Vdc 7.5mA 34mA 500 8.33msec 8.33msec
17-32Vdc 1Vdc 13mA 24mA 1500 8.33msec 8.33msec
Input Specifications Input voltage Drop out voltage Min. input current (for on-state) Maximum input current Input Resistance (Ohms) Turn-on time* Turn-off time *Random SSR’s turn on in less than 100µs
General Characteristics Operating Temperature (°C) Storage Temperature (°C) Input to output isolation Input/output to ground isolation Input to output capacitance Operating Frequency Housing Material
-40 to +80 -40 to +100 4000Vrms 2500Vrms 8pF (typical) 47 to 63 Hz UL 94V0 (self extinguishing)
Standards of Compliance CE Compliant with the LVD 73/23/EEC UL / cUL Recognized per UL 508 and CSA C22.2 no. 14-M91
Rating 25 Amp 25 Amp 40 Amp 40 Amp Rating 25 Amp 25 Amp 40 Amp 40 Amp 84 137 011
Zero Crossing Output Output Input 24-280Vac 4-15Vdc 24-280Vac 17-32Vdc 24-280Vac 4-15Vdc 24-280Vac 17-32Vdc Random Fire Output Output Input 24-280Vac 4-15Vdc 24-280Vac 17-32Vdc 24-280Vac 4-15Vdc 24-280Vac 17-32Vdc
Part Number 84 140 000 84 140 010 84 140 200 84 140 210 Part Number 84 140 100 84 140 110 84 140 300 84 140 310
DERATE CURVE: 25 AMP GN Series Dual SSRs
Ambient Temperature (°C)
DERATE CURVE: 40 AMP GN Series Dual SSRs
1.131
▲
0.375
▲
▲
Ambient Temperature (°C)
▲
▲
▲
40 amp dual AC output relays Output voltage from 24 to 280 Vac Direct bond copper substrate Back to back dual SCR output 4000 Vac optical isolation Zero crossing or random turn on UL/cUL E79183, CE Compliant
Combined Channel Output Current (Amperes)
Combined Channel Output Current (Amperes)
0.175
Mating Connector AMP #640441-4
▲
▲
▲
1.256
0.886 ▼
▼
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-17
GNA5 Series Solid State Relays
Current ratings 10 and 25 amps Output voltage 24 to 280 Vac Triac output Regulated AC and DC inputs 4000 Vac optical isolation UL E79183, CSA LR 38595, TUV Approved, CE Compliant
Output Specifications
1
Part Numbers
Voltage range (Vrms) Peak Voltage (Vpk, t = 1 min.) Off-state leakage (@ max. line voltage & Ta = 25°C) Output Current (Mounted on proper heat sink, see deratings) Minimum Current (mArms) Max. 1 cycle surge current (Apk, Ta = 25°C) Max. 1 second surge current (Apk, Ta = 25°C) Forward voltage drop (Vpk @ Imax, Ta = 25°C) I2T (60Hz, 1/2 cycle) Rjb (thermal res. Junction to baseplate, °C/W) Static off-state dv/dt (Vµs, Ta = 25°C) Minimum heat sink @ ambient (for max current = °C/W & Ta)
00 49 13 84
24 - 280Vac 600 0.10mArms
48 - 660Vac 1200 .25mArms
10
25
75
100
125
100 100
100 250
100 1000
100 1200
100 1700
30
75
225
300
375
1.5
1.3
1.3
1.3
1.3
41 2.2
240 1.7
5000 0.16
6000 0.155
12.041 0.15
500
500
500
500
500
3.0@ 40°C
1.0@ 40°C
0.7@ 40°C
0.6@ 40°C
0.4@ 40°C
Input Specifications
Rating 10 Amp
Output 24-280Vac
25 Amp
24-280Vac
Input 90-280Vac 3-32Vdc 90-280Vac 3-32Vdc
84 84 84 84
IP00 134 901 134 900 134 911 134 910
84 137 001 84 137 000 84 137 011
Quick connect terminals: 3/16" input and 1/4" output Rating Output Input IP00 10 Amp 24-280Vac 90-280Vac 84 134 905 3-32Vdc 84 134 904 25 Amp 24-280Vac 90-280Vac 84 134 915 3-32Vdc 84 134 914 Quick connect terminals: 1/4" input and 1/4" output Rating Output Input IP00 10 Amp 24-280Vac 90-280Vac 84 134 909 3-32Vdc 84 134 907 25 Amp 24-280Vac 90-280Vac 84 134 919 3-32Vdc 84 134 917
DIMENSIONS IN INCHES 90-280Vac 10Vrms 8.5mArms 5mArms 20ms 30ms 1/L1
4/A2
Input voltage* 3-32Vdc Drop out voltage 1Vdc Max. input current 14mA Min. input current (for on-state) 9.5mA Input Resistance Current Regulated Turn-on time** 8.33ms Turn-off time 8.33ms *4-32Vdc for 48-660Vac models **Random SSR’s turn on in less than 100µs
General Characteristics -20 to +80
INPUT 2/T1
-40 to +100 4000Vrms 2500Vrms 8pF (typical) 47 to 63 Hz UL 94V0 (self extinguishing)
3/A1
Operating Temperature (°C) Storage Temperature (°C) Input to output isolation Input/output to ground isolation Input to output capacitance Operating Frequency Housing Material
OUTPUT
Safety and Noise Immunity Compliance CE Compliant with the LVD 73/23/EEC UL / cUL Recognized per UL 508 and CSA C22.2 no. 14-M91 E46203 TUV EN60950 IEC 61000-4-2: Electrostatic Discharge – Level 3 IEC 61000-4-3: Radiated Electromagnetic Noise – Level 3 IEC 61000-4-4: Electrically Fast Transients – Level 3 IEC 61000-4-5: Electrical Surges – Level 3 IEC 61000-4-6: Conducted Electromagnetic Noise – Level 3 IEC 61000-4-11 CISPR 11 – Class A: Allowable Levels of Conducted and Radiated Noise for Industrial Environments
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-11
GN Series Solid State Relays
Current ratings from 10 to 125 amps Output voltage from 24 to 660 Vac Back to back SCR’s for severe inductive loads Direct bond copper substrate Improved power lead frame design LED input status indicator
Transient protection built in 4000 Vac optical isolation Available with IP20 “touch-safe” cover UL E79183, CSA LR 38595, TUV Approved, CE Compliant
Output Specifications Voltage range (Vrms) Peak Voltage (Vpk, t = 1 min.) Off-state leakage (@ max. line voltage & Ta = 25°C)
24 - 280Vac 600 .1mArms 0.1
48 - 660Vac 1200 .25mArms 0.25
25
50
75
100
125
50 300
100 750
100 1000
100 1200
100 1700
75
150
225
300
375
1.35
1.35
1.3
1.3
1.3
937 0.4
2458 0.25
5000 0.16
6000 0.155
12.041 0.15
500
500
500
500
500
1.5@ 50°C
1.0@ 40°C
0.7@ 40°C
0.6@ 40°C
0.4@ 40°C
Rating 10 Amp
25 Amp
Output 24-280Vac
24-280Vac 48-660Vac
50 Amp
24-280Vac 48-660Vac
75 Amp
24-280Vac 48-660Vac
100 Amp
24-280Vac 48-660
Input Specifications Input voltage* Drop out voltage Max. input current Min. input current (for on-state) Input Resistance Turn-on time** Turn-off time *4-32Vdc for 48-660Vac models **Random SSR’s turn on in less than 100µs
3-32Vdc 90-280Vac* 1Vdc 10Vrms 14mA 10mArms 7mA 5mArms Current Regulated 8.33ms 20ms 8.33ms 30ms
125 Amp
-20 to +80
Safety and Noise Immunity Compliance CE Compliant with the LVD 73/23/EEC UL / cUL Recognized per UL 508 and CSA C22.2 no. 14-M91 TUV EN60950 IEC 1000-4-2: Electrostatic Discharge – Level 3 IEC 1000-4-3: Radiated Electromagnetic Noise – Level 3 IEC 1000-4-4: Electrically Fast Transients – Level 3 IEC 1000-4-5: Electrical Surges – Level 3 IEC 1000-4-6: Conducted Electromagnetic Noise – Level 3 CISPR 11 – Class A: Allowable Levels of Conducted and Radiated Noise for Industrial Environments
Input 90-280Vac 3-32Vdc 90-280Vac 3-32Vdc 90-280Vac 3-32Vdc 90-280Vac 3-32Vdc 90-280Vac 3-32Vdc 90-280Vac 3-32Vdc 90-280Vac 3-32Vdc 90-280Vac 3-32Vdc 90-280Vac 3-32Vdc 90-260Vac 3-32Vdc 90-280Vac 3-32Vdc 90-280Vac 3-32Vdc
84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84
IP00 134 001 134 000 134 101 134 100 134 011 134 010 134 111 134 110 134 021 134 020 134 121 134 120 134 031 134 030 134 131 134 130 134 041 134 040 134 141 134 140 134 081 134 080 134 181 134 180
84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84
IP20 137 001 137 000 137 101 137 100 137 011 137 010 137 111 137 110 137 021 137 020 137 121 137 120 137 031 137 030 137 131 137 130 137 041 137 040 137 141 137 140 137 081 137 080 137 181 137 180
Input 3-32Vdc 3-32Vdc 3-32Vdc 3-32Vdc 3-32Vdc 3-32Vdc 3-32Vdc 3-32Vdc 3-32Vdc 3-32Vdc 3-32Vdc 3-32Vdc
84 84 84 84 84 84 84 84 84 84 84 84
IP00 134 200 134 300 134 210 134 310 134 220 134 320 134 230 134 330 134 240 134 340 134 280 134 380
84 84 84 84 84 84 84 84 84 84 84 84
IP20 137 200 137 300 137 210 137 310 137 220 137 320 137 230 137 330 137 240 137 340 137 280 137 380
Random SSR’s Rating 10 Amp 25 Amp
-40 to +100 4000Vrms 2500Vrms 8pF (typical) 47 to 63 Hz UL 94V0 (self extinguishing)
24-280Vac 48-660Vac
General Characteristics Operating Temperature (°C) Storage Temperature (°C) Input to output isolation Input/output to ground isolation Input to output capacitance Operating Frequency Housing Material
IP00
Part Numbers (Zero Crossing)
48-660Vac Output Current (Mounted on 10 proper heat sink, see deratings) Minimum Current (mArms) 50 Max. 1 cycle surge current 150 (Apk, Ta = 25°C) Max. 1 second surge current 30 (Apk, Ta = 25°C) Forward voltage drop 1.35 (Vpk @ Imax, Ta = 25°C) 416 I2T (60Hz, 1/2 cycle) Rjb (thermal res. Junction to 0.5 baseplate, °C/W) Static off-state dv/dt 500 (Vµs, Ta = 25°C) Minimum heat sink @ ambient 3.0@ (for max current = °C/W & Ta) 70°C
IP20
50 Amp 75 Amp 100 Amp 125 Amp
Output 24-280Vac 48-660Vac 24-280Vac 48-660Vac 24-280Vac 48-660Vac 24-280Vac 48-660Vac 24-280Vac 48-660Vac 24-280Vac 48-660Vac
Dimensions – see page 1-12
*For Ambient temperatures above 40°C the maximum control voltage must not exceed 250Vac.
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-10
DIMENSIONS IN INCHES
1/L1
4/A2
1/L1
4/A2
INPUT 2/T1
3/A1
2/T1
3/A1
OUTPUT
DERATING CURVES DERATE CURVES: GN SSR-25 AMP TRIAC OUTPUT
Load Current (Amperes)
Load Current (Amperes)
DERATE CURVES: GN SSR-10 AMP TRIAC OUTPUT
Ambient Temperature (°C)
Ambient Temperature (°C)
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-12
DERATE CURVES: GN SSR-25 AMP SCR OUTPUT (1200 & 600V)
Load Current (Amperes)
Load Current (Amperes)
DERATE CURVES: GN SSR-10 AMP SCR OUTPUT
1
Ambient Temperature (°C)
DERATE CURVES: GN SSR-50 AMP SCR OUTPUT (1200 & 600V)
DERATE CURVES: GN SSR-75 AMP SCR OUTPUT (1200 & 600V)
Load Current (Amperes)
Load Current (Amperes)
Ambient Temperature (°C)
0.5°C/W 0.7°C/W 1.0°C/W 1.5°C/W
Ambient Temperature (°C)
DERATE CURVES: GN SSR-100 AMP SCR OUTPUT (1200 & 600V)
DERATE CURVES: GN SSR-125 AMP SCR OUTPUT (1200 & 600V)
Load Current (Amperes)
Load Current (Amperes)
Ambient Temperature (°C)
Ambient Temperature (°C)
Ambient Temperature (°C)
Products and specifications subject to change without notice.
Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-13
280 VOLT DUAL SOLID STATE RELAYS 40 amp dual AC output relays Output voltage from 24 to 280 Vac Direct bond copper substrate Back to back dual SCR output 4000 Vac optical isolation Zero crossing or random turn on UL/cUL Recognized, CE Compliant
Part Numbers
25
40
100 500
100 780
150
234
1.4
1.3
1250 0.6
2435 0.4
500
500
4-15Vdc 1Vdc 7.5mA 34mA 500 8.33msec 8.33msec
17-32Vdc 1Vdc 13mA 24mA 1500 8.33msec 8.33msec
Input Specifications Input voltage Drop out voltage Min. input current (for on-state) Maximum input current Input Resistance (Ohms) Turn-on time* Turn-off time
QC, Mated/Locking Input
24-280Vac 550 0.1
QC, Standard Input Pins
Output Specifications Voltage range (Vrms) Peak Voltage (Vpk , t = I min.) Off-state leakage mArms (@ max. line voltage & Ta = 25ºC) Output Current (Mounted on proper heat sink, see deratings) Minimum Current (mArms) Max. 1 cycle surge current (Apk, Ta = 25ºC) Max. 1 second surge current (Apk, Ta = 25ºC) Forward voltage drop (Vpk @ Imax, Ta = 25ºC) I2T (60Hz, ½ cycle) Rjb (thermal res. Junction to baseplate, ºC/W) Static off-state dv/dt (Vµs, Ta = 25ºC)
* Random SSR's turn on in less than 100µs
-40 to + 80 -40 to + 100 4000Vrms 2500Vrms 8pF (typical) 47 to 63 Hz UL 94V0 (self extinguishing
Standards of Compliance CE Compliant with the LVD 73/23/EEC UL / cUL Recognized per UL 508 and CSA C22.2 no. 14-M91
Standard Input Pins
General Characteristics Operating Temperature (ºC) Storage Temperature (ºC) Input to output isolation Input/output to ground isolation Input to output capacitance Operating Frequency Housing Material
1/4" Quick Connect Zero Crossing Output Rating Output Input Part Number 25 Amp 24-280Vac 4-15Vdc 84140000 25 Amp 24-280Vac 17-32Vdc 84140010 40 Amp 24-280Vac 4-15Vdc 84140200 40 Amp 24-280Vac 17-32Vdc 84140210 Random Fire Output Rating Output Input Part Number 25 Amp 24-280Vac 4-15Vdc 84140100 25 Amp 24-280Vac 17-32Vdc 84140110 40 Amp 24-280Vac 4-15Vdc 84140300 40 Amp 24-280Vac 17-32Vdc 84140310 Locking Connector Part Numbers Zero Crossing Output Rating Output Input Part Number 25 Amp 24-280Vac 4-15Vdc 84140800 25 Amp 24-280Vac 17-32Vdc 84140810 40 Amp 24-280Vac 4-15Vdc 84140900 40 Amp 24-280Vac 17-32Vdc 84140910 Random Fire Output Rating Output Input Part Number 25 Amp 24-280Vac 4-15Vdc 84140801 25 Amp 24-280Vac 17-32Vdc 84140811 40 Amp 24-280Vac 4-15Vdc 84140901 40 Amp 24-280Vac 17-32Vdc 84140911 Mating Connector: Molex # 14-56-2042 Screw Terminals Part Numbers Zero Crossing Output Rating Output Input Part Number 25 Amp 24-280Vac 4-15Vdc 84140003 25 Amp 24-280Vac 17-32Vdc 84140013 40 Amp 24-280Vac 4-15Vdc 84140203 40 Amp 24-280Vac 17-32Vdc 84140213 Random Fire Output Rating Output Input Part Number 25 Amp 24-280Vac 4-15Vdc 84140103 25 Amp 24-280Vac 17-32Vdc 84140113 40 Amp 24-280Vac 4-15Vdc 84140303 40 Amp 24-280Vac 17-32Vdc 84140313
See next page thermal curves.
Mating Connector for 841408xxx and 841409xxx Molex # 14-56-2042
Products and specifications subject to change without notice Order/Technical Support - Tel: (800) 677-5311 / Fax: (800) 677-3865 / www.crouzet-usa.com
660 VOLT DUAL SOLID STATE RELAYS 40 amp dual AC output relays Output voltage from 48 to 660 Vac Direct bond copper substrate Back to back dual SCR output 4000 Vac optical isolation Zero crossing or random turn on UL/cUL Recognized, CE Compliant
Part Numbers
25
40
100 500
100 780
150
234
1.4
1.3
1250 0.6
2435 0.4
500
500
4-15Vdc 1Vdc 7.5mA 34mA 500 8.33msec 8.33msec
17-32Vdc 1Vdc 13mA 24mA 1500 8.33msec 8.33msec
Input Specifications Input voltage Drop out voltage Min. input current (for on-state) Maximum input current Input Resistance (Ohms) Turn-on time* Turn-off time
Standard Input Pins
48-660Vac 1000 0.25
QC, Standard Input Pins
Output Specifications Voltage range (Vrms) Peak Voltage (Vpk , t = I min.) Off-state leakage mArms (@ max. line voltage & Ta = 25ºC) Output Current (Mounted on proper heat sink, see deratings) Minimum Current (mArms) Max. 1 cycle surge current (Apk, Ta = 25ºC) Max. 1 second surge current (Apk, Ta = 25ºC) Forward voltage drop (Vpk @ Imax, Ta = 25ºC) I2T (60Hz, ½ cycle) Rjb (thermal res. Junction to baseplate, ºC/W) Static off-state dv/dt (Vµs, Ta = 25ºC)
1/4" Quick Connect Zero Crossing Output Rating Output Input Part Number 25 Amp 48-660Vac 4-15Vdc 84140500 25 Amp 48-660Vac 17-32Vdc 84140510 40 Amp 48-660Vac 4-15Vdc 84140600 40 Amp 48-660Vac 17-32Vdc 84140610 Random Fire Output Rating Output Input Part Number 25 Amp 48-660Vac 4-15Vdc 84140501 25 Amp 48-660Vac 17-32Vdc 84140511 40 Amp 48-660Vac 4-15Vdc 84140601 40 Amp 48-660Vac 17-32Vdc 84140611 Screw Terminals Part Numbers Zero Crossing Output Rating Output Input Part Number 25 Amp 48-660Vac 4-15Vdc 84140503 25 Amp 48-660Vac 17-32Vdc 84140513 40 Amp 48-660Vac 4-15Vdc 84140603 40 Amp 48-660Vac 17-32Vdc 84140613 Random Fire Output Rating Output Input Part Number 25 Amp 48-660Vac 4-15Vdc 84140530 25 Amp 48-660Vac 17-32Vdc 84140531 40 Amp 48-660Vac 4-15Vdc 84140630 40 Amp 48-660Vac 17-32Vdc 84140631
* Random SSR's turn on in less than 100µs
General Characteristics Operating Temperature (ºC) Storage Temperature (ºC) Input to output isolation Input/output to ground isolation Input to output capacitance Operating Frequency Housing Material
-40 to + 80 -40 to + 100 4000Vrms 2500Vrms 8pF (typical) 47 to 63 Hz UL 94V0 (self extinguishing)
Standards of Compliance CE Compliant with the LVD 73/23/EEC UL / cUL Recognized per UL 508 and CSA C22.2 no. 14-M91
Products and specifications subject to change without notice Order/Technical Support - Tel: (800) 677-5311 / Fax: (800) 677-3865 / www.crouzet-usa.com