Preview only show first 10 pages with watermark. For full document please download

Solid State Relay Updates

   EMBED


Share

Transcript

DIGITAL I/O MODULES 17.5mm DIN-RAIL OUTPUT MODULES FEATURES:  UL and cUL (E46203) Recognized  CE Compliant  DIN-Rail Mountable (17.5mm wide) Single Point Output Modules  AC Output Rating 5 Amp at 12 to 280 VAC, with 350 Amp Single Cycle Surge Capability  DC Output Rating 3 Amp at 5 to 60 VDC  4 to 32 VDC Input Current regulated  Zero Voltage Turn-on for AC Module  4 kV Optical Isolation with LED Indicator  Barrier Strips Accept 14 to 28 AWG Wire  Configured for Panel Mounting OUTPUT SPECIFICATIONS: (1) Model Number Parameter Nominal Line Voltage Minimim Line Voltage Maximum Line Voltage Max Off-State Voltage (3) Max Off-State Leakage (4) Static Off-State dv/dt (5) Maximum Rated On-State Current (6) Min On-State Current Max Surge Current (7) On-State Voltage Drop (8) INPUT SPECIFICATIONS: (1) 84130105 84130108 84130104 120/240 VAC 12 VAC 280 VAC 800 Vpeak .1 mA 50 V / µ sec 5-60 VDC 5 VDC 60 VDC 60 VDC 10 µA N/A 5.0 Arms 50 mArms 350 Apeak 1.85 Vpeak 3.0 A 10 mA 5.0 A 1.6 VDC 84130104 84130105 84130108 Model Number Parameter Nominal Voltage Minimum Voltage Maximum Voltage Drop-Out Voltage Maximum Current (2) Resistance 4-32 VDC 4 VDC 32 VDC 1 VDC 22 mA Current Regulated GENERAL SPECIFICATIONS: (1) Model Number Parameter Operating Temperature Range Storage Temperature Range Maximum Turn-on Time (9) (11) Maximum Turn-off Time (9) Input/Output Isolation Voltage (10) Input/Output Capacitance (typical) Line Frequency Range DIMENSIONS: 17.50 (0.689) 3 2 4 1 Units °C °C mSec mSec VAC pF Hertz 84130105 84130108 -30 to 80 -40 to 100 8.33 8.33 4000 6 47 to 63 84130104 -30 to 80 -40 to 100 0.05 0.05 4000 4 DC Notes: (1) Specifications apply to an ambient temperature of -30 to 80°C unless otherwise noted. (2) Modules are current limited +/-10% at 25°C . (3) Maximum 1 minute duration for OAC modules when applied as a DC voltage rather than peak AC voltage. (4) At maximum line voltage, 25°C for OAC modules, and 80°C for ODC modules. (5) Minimum dv/dt per EIA/NARM RS443, method RS397. dv/dt ratings do not apply to ODC modules. (6) At 25°C, derate 84130105 modules by 46.9 mA/°C to 80°C; derate 84130104 modules by 21.5 mA/°C to 80°C. (7) At 25°C. Maximum duration: 1 AC cycle for OAC modules, 1 second for ODC modules. (8) At maximum rated on-state current and 25°C. (9) At maximum line voltage, maximum rated output current, nominal input voltage, 25°C. Switching speed of OAC modules based upon 60 Hz line frequency. (10) At 25°C for 1 second maximum duration. DIN RAIL (11) For 84130108 turn-on time is 0.1 mSec. AC OUTPUT MODULE 81.00 (3.189) 18.00 (0.709) 45.00 (1.772) DIN RAIL DC OUTPUT MODULE 49.50 (1.949) 65.00 (2.559) 2 1 +VDC LOAD* (A) 2 –VDC VAC 1 VAC VAC SCREW TERMINALS VACLO +VCC REPLACEABLE 5A FUSE LOAD* (B) LOAD* (A) SCREW TERMINALS 2 REPLACEABLE 5A FUSE 3 LED LOAD* (B) S N U B ZERO VOLTAGE CIRCUIT +VCC LOGIC SUPPLY 3 LED Rc AMPLIFIER +VCC LOGIC SUPPLY 4 INPUT 4 INPUT *LOAD MAY BE WIRED IN LOCATION A OR B DIMENSIONS: MILLIMETERS (INCHES) TOLERANCE: ±0.020 (±0.50) 40.65 (1.600) *LOAD MAY BE WIRED IN LOCATION A OR B. DC INDUCTIVE LOADS MUST BE DIODE SUPRESSED TO PREVENT DAMAGE TO THE I/O MODULE. (EQUIVALENT CIRCUIT DIAGRAMS) Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 2-33 SOLID STATE RELAYS 22.5mm DIN-RAIL SSR FEATURES:        DIN-Rail or panel mount. Compact Size. LED indicator. AC or DC control. Zero AC turn-on models. 12 and 25 Amp Outputs UL, cUL Recognized (25 Amp Model: UL Rating 20 Amps) 12 Amp .5 HP @ 240 VAC 20 Amp 1.5 HP @ 240 VAC  CE Compliant Per EN60950  UL E79183 DIMENSIONS: inches (mm) EQUIVALENT CIRCUIT CURRENT LIMITER VISIBLE LED GREEN 1 5.15 (0.203) 4.50 (0.177) OVER VOLTAGE PROTECTION TRANSIENT PROTECTION U VOLTAGE DETECTOR OVER VOLTAGE PROTECTION OUTPUT 2 3OUTPUT 2 3 DC INPUT 22.5mm ZERO TURN-ON 43.85 [1.725] 11.25 (0.443) 4.50 (0.177) Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-4 102.80 [4.047] 6.80 [0.268] 84130101 SOLID STATE RELAY 9.00 (0.354) 87.70 (3.453) 1 4 + SNUBBER NETWORK CURRENT LIMITER VISIBLE LED GREEN 4+ GORDOS 5.00 (0.197) AC INPUT 22.5mm ZERO TURN-ON 1 97.80 (3.85) INPUT 2 80.00 (3.150) VOLTAGE DETECTOR SNUBBER TRANSIENT PROTECTION U 3 - 22.50 (0.886) 5.24 (0.208) 4 SOLID STATE RELAYS 22.5mm DIN-RAIL SSR 1 INPUT SPECIFICATIONS: 84130101 84130103 84130116 4-32 VDC 1.0 VDC 12 8.33 8.33 Zero Crossing 0.00˝-.078˝ 84130150 84130152 84130158 90-140 VAC 10 VAC 6 20 30 Zero Crossing 0.00˝-.078˝ 84130100 84130102 84130118 180-280 VAC 10 VAC 6 20 30 Zero Crossing 0.00˝-.078˝ Model Number 84130100 84130101 84130102 84130103 Parameter Line Voltage Peak Off-State Voltage (2) Maximum Off-State Leakage (3) Static Off-State dv/dt (4) Minimum On-State Current Maximum On-State Current (5) Maximum 1-Cycle Surge (6) Maximum 1-Second Surge (7) Peak On-State Voltage Drop (8) l2t (60 Hz, Half-Cycle) Output Type Wire Size 84130150 24-280 600 .1 200 100 12 250 60 1.85 260 TRIAC 0.20˝-.078˝ 84130152 24-280 800 .1 600 100 20 400 140 1.8 600 ALTERNISTOR 0.20˝-.078˝ 84130116 84130117 84130118 84130158 48-660 1200 .25 500 100 25 250 75 1.6 260 B/B SCR 0.20˝-.078˝ Model Number Parameter Control Voltage Drop Out Voltage Maximum Input Current (1) Maximum Turn-On Time Maximum Turn-Off Time Type Wire Size 84130117 Units 4-32 VDC 1.0 VDC 12 0.1 8.33 Random Turn-on 0.00˝-.078˝ mA ms ms OUTPUT SPECIFICATIONS: Units Vms Vpeak mArms V/Sec mArms Arms Apeak Apeak Vpeak A2 sec GENERAL SPECIFICATIONS: Parameter Operating Temperature Range Storage Temperature Range Input to Output Isolation Voltage (9) Input/Output to Ground Isolation Voltage (9) Capacitance (Input to Output) Line Frequency Range All Devices -20 to 80°C -40 to 100°C 4000 Vrms 2500 Vrms 8 pF 47 to 63 Hz Notes: (1) At maximum input voltage. Input is regulated and current limited. (2) Do not apply continuously for over 1 minute. (3) At maximum line voltage, Ta = 25°C. (4) Minimum dv/dt per EIA/NARM R5443, method RS397, 25°C. (5) Mounted in vertical position on DIN-Rail. Free Air. (6) Non-repetitive 60 Hz, resistive load, Ta = 25°C. (7) Non-repetitive 50 or 60 Hz, resistive load, Ta = 25°C. (8) At maximum rated current. (9) Limited to 1 mA for 1 second, Ta = 25°C. Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-5 SOLID STATE RELAYS 45mm DIN-RAIL SSR FEATURES:      DIN-Rail or Panel Mount. Compact Size. LED Indicator. AC or DC Control. Zero AC or Random turn-on models. 35 and 45 Amp Outputs. 4 kV Optical Isolation. CE Compliant Per EN60950 UL, cUL Recognized E79183     45.00 (1.772) 3.20 (0.126) 35.70 (1.406) 12.20 (0.480) CURRENT LIMITER 1 VISIBLE LED 4 5.00 (0.197) 3 AC 45mm THREE PHASE 2 9.00 (0.354) INPUT 4-32 VDC + 4 AC INPUT EQUIVALENT CIRCUIT CURRENT LIMITER OUTPUT 35 AMPS 48 TO 530 VAC 80.00 (3.150) 2 88.00 (3.858) 84130111 SOLID STATE RELAY 87.70 (3.453) PROTECTION OVER VOLTAGE PROTECTION SNUBBER GORDOS 1 3 9.30 (0.366) 1 VISIBLE LED 2 102.80 [4.047] SNUBBER OVER VOLTAGE PROTECTION 6.80 [0.268] PROTECTION 4 3 DC 45mm THREE PHASE RANDOM DC INPUT EQUIVALENT CIRCUIT Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-6 SOLID STATE RELAYS INPUT SPECIFICATIONS: Model Number Parameter 84130111 84130113 84130112 84130114 84130110 84130115 Control Voltage Drop Out Voltage Maximum Input Current (1) Maximum Turn-On Time Maximum Turn-Off Time Type Wire Size 4-32 VDC 1.0 VDC 10 8.33 8.33 Zero Crossing .020˝-.078˝ 4-32 VDC 1.0 VDC 10 0.1 8.33 Random Turn-on .020˝-.078˝ 90-280 VAC 10 VAC 6 20 30 Zero Crossing .020˝-.078˝ 1 Units mA ms ms OUTPUT SPECIFICATIONS: Model Number 84130110 84130111 84130112 84130113 84130114 84130115 48-530 1200 .25 500 100 35 750 145 1.6 1000 .040˝-.220˝ 48-530 1200 .25 500 100 45 750 145 1.6 1000 .040˝-.220˝ Parameter Line Voltage Peak Off-State Voltage (2) Maximum Off-State Leakage (3) Static Off-State dv/dt (4) Minimum On-State Current Maximum On-State Current (5) Maximum 1-Cycle Surge (6) Maximum 1-Second Surge (7) Peak On-State Voltage Drop (8) I2t (60Hz, Half-Cycle) Wire Size Units Vrms Vpeak mArms V/Sec mArms Arms Apeak Apeak Vpeak A2 sec GENERAL SPECIFICATIONS: Parameter All Devices Operating Temperature Range Storage Temperature Range Input to Output Isolation Voltage (9) I/O to Ground Isolation Voltage (9) Capacitance (Input to Output) Line Frequency Range -20 to 80°C -40 to 100°C 4000 Vrms 2500 Vrms 8 pF 47 to 63 Hz Notes: (1) (2) (3) (4) (5) (6) (7) (8) (9) At maximum input voltage. Input is regulated and current limited. Do not apply continuously for over 1 minute. At maximum line voltage, Ta = 25°C. Minimum dv/dt per EIA/NARM R5443, method RS397, 25°C. Mounted in vertical position on DIN-Rail. Free Air. Non-repetitive 60 Hz, resistive load, Ta = 25°C. Non-repetitive 50 or 60 Hz, resistive load, Ta = 25°C. At maximum rated current. Limited to 1 mA for 1 second, Ta = 25°C. Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-7 SOLID STATE RELAYS 90mm 2 and 3 PHASE DIN-RAIL SSR FEATURES:         DIN-Rail or panel mount. Compact Size. LED indicator. AC or DC control. Zero AC or random turn-on models. 4 kV optical isolation. UL, cUL Recognized (File E79183) CE Compliant Per EN60950 90.00 (3.543) 80.70 (3.177) S/L2 R/L1 97.20 (3.827) 4.50 (0.177) T/L3 87.70 (3.827) 87.70 (3.827) 84130310 SOLID STATE RELAY OUTPUT: 25 OUTPUT: 20 AMPS AMPS 48660 VAC 48-660 VAC U/T1 98.00 (3.858) GORDOS GRD V/T2 V/T1 + A2 A1 DIMENSIONS: inches (mm) TOLERANCE: ±0.20 (±0.008) 9.30 (0.366) CURRENT CURRENT LIMITER LIMITER VISIBLE LED VISIBLE LED GREEN GREEN U/T1 U/T1 VISIBLE LED VISIBLE LED GREEN GREEN U/ T1 U/T1 A1 VOLTAGE VOLTAGE DETECTOR DETECTOR VOLTAGE VOLTAGE DETECTOR DETECTOR SNUBBER SNUBBER U OVER OVER VOLTAGE VOLTAGE PROTECTION PROTECTION OVER OVER VOLTAGE VOLTAGE PROTECTION PROTECTION SNUBBER U CURRENT CURRENT LIMITER LIMITER SNUBBER A1 R/L1 R/L1 V/T2 V/T2 U VOLTAGE VOLTAGE DETECTOR DETECTOR SNUBBER SNUBBER TRANSIENT TRANSIENT PROTECTION PROTECTION OVER OVER VOLTAGE VOLTAGE PROTECTION PROTECTION U INPUT VOLTAGE VOLTAGE DETECTOR DETECTOR U/T1 U/T1 SNUBBER V/T2 V/T2 SNUBBER TRANSIENT TRANSIENT PROTECTION PROTECTION R/L1 R/L1 OUTPUT OVER OVER VOLTAGE VOLTAGE PROTECTION PROTECTION S/L2 S/L2 W/T3 W/T3 S/L2 S/L2 VOLTAGE VOLTAGE DETECTOR DETECTOR OVER OVER VOLTAGE VOLTAGE PROTECTION VOLTAGE VOLTAGE DETECTOR DETECTOR T/L3 T/L3 A2 PROTECTION T/L3 T/L3 A2 3 PHASE 90mm DC INPUT ZERO CROSSING OR RANDOM 3 PHASE 90mm DC INPUT OVER OVER VOLTAGE VOLTAGE PROTECTION PROTECTION SNUBBER SNUBBER SNUBBER U U SNUBBER W/T3 W/T3 3 PHASE 90mm AC INPUT ZERO CROSSING 3 PHASE 90mm AC INPUT ZERO CROSSING NOTE: V/T2 to S/L2 is shorted on 2 phase models. Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-8 SOLID STATE RELAYS 90mm 2 and 3 PHASE DIN-RAIL SSR 1 INPUT SPECIFICATIONS: Model Number Parameter Control Voltage Drop Out Voltage Maximum Input Current (1) Maximum Turn-On Time Maximum Turn-Off Time Type OUTPUT SPECIFICATIONS: Model Number Parameter Line Voltage Peak Off-State Voltage (2) Maximum Off-State Leakage (3) Static Off-State dv/dt (4) Minimum On-State Current Maximum On-State Current per phase (5) Maximum 1-Cycle Surge (6) Maximum 1-Second Surge (7) Peak On-State Voltage Drop (8) l2t (60 Hz, Half-Cycle) 84130310 84130220 4-32 VDC 1.0 VDC 22 8.33 8.33 Zero Crossing 84130312 84130221 4-32 VDC 1.0 VDC 22 0.1 8.33 Random Turn-on Three Phase 84130310 84130311 84130312 Two Phase 84130220 84130221 84130222 48-530 1200 .25 500 100 20 750 145 1.6 1000 48-530 1200 .25 500 100 25 750 145 1.6 1000 84130311 84130222 90-280 VAC 10 VAC 6 20 30 Zero Crossing Units mA ms ms Units Vrms Vpeak mArms V/Sec mArms Arms Apeak Apeak Vpeak A2 sec GENERAL SPECIFICATIONS: Parameter Operating Temperature Range Storage Temperature Range Input to Output Isolation Voltage (9) Input/Output to ground Isolation Voltage (9) Capacitance (Input to Output) Line Frequency Range All Devices -20 to 80°C -40 to 100°C 4000 Vrms 2000 Vrms 8 pF 47 to 63 Hz Notes: (1) At maximum input voltage. Input is regulated and current limited. (2) Do not apply continuously for over 1 minute. (3) At maximum line voltage, Ta = 25°C. (4) Minimum dv/dt per EIA/NARM R5443, method RS397, 25°C. (5) Mounted in vertical position on DIN-Rail. Free Air. Derated by 27.3 mA/°C to 80°C. (6) Non-repetitive 60 Hz, resistive load, Ta = 25°C. (7) Non-repetitive 50 or 60 Hz, resistive load, Ta = 25°C. (8) At maximum rated current. (9) Limited to 1 mA for 1 second, Ta = 25°C. Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-9 SOLID STATE RELAYS THREE-PHASE MOTOR REVERSING RELAYS  Convenient Self-Contained Design Eases Installation and Wiring  24 to 600 VAC Output Voltage Range Suitable for Many Applications  1000 Volts Peak Blocking Voltage Helps Protect Against Transients in Harsh Electrical Environments  5000 VAC Isolation  3 to 32 Control Voltage for a Wide Variety of Logic Circuit Applications  Compact Sealed Package with Screw Terminals  Interlock Circuit Prevents Inadvertant Actuation of Both Directions  UL and cUL Recognized E79183  CE Compliant ; L1 O V P S N U B B E R O V P S N U B B E R O V P S N U B B E R O V P S N U B B E R ;U OUTPUT INPUT A1F + FORWARD A2 – CONSTANT CURRENT AND INTERLOCKING CIRCUIT REVERSE A1R + ➝ OVER VOLTAGE PROTECTION ; L2 ; UV EQUIVALENT CIRCUIT 4.09 (104,0) 3.19 (81,0) OUTPUT TERMINALS 4.0 mm (4) 2.4 (61,0) DIMENSIONS: INCHES (MILLIMETERS) TOLERANCE:+-0.020 ( +- 0,50) 1.6 (41,0) 0.3 (7,62) 0.82 (21,0) 1.87 (47,6) L1 0.88 (22,6) U Y L2 0.2 (5,3) 2.89 (73,5) 0.73 (18,5) V A1F A2 A1R 0.47 (12,1) 0.25 (6,35) INPUT TERMINALS 3.5 mm (3) 3.62 (92,0) Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-22 SOLID STATE RELAYS THREE-PHASE MOTOR REVERSING RELAYS 1 INPUT SPECIFICATIONS: (1) MODEL NUMBER Parameter Voltage Range Drop Out Voltage Control Current (2) GA012D25 GA012D40 3.0 to 32 1.0 25 Units VDC VDC mA GA012D25 GA012D40 24 to 660 1200 25 0.2 .25 270 365 1.6 500 24 to 660 1200 40 0.2 .25 450 1000 1.6 500 OUTPUT SPECIFICATIONS: (1) MODEL NUMBER Parameter Line Voltage Range Maximum Peak Off-State Voltage (3) Rated Current (4) Minimum Current Maximum Off-State Leakage (5) One Cycle Surge Current (6) l2t Fusing Current Maximum On-State Voltage Drop (7) Off-State dv/dt (8) Units VAC Vpeak Arms Arms mArms Apeak A Seconds Volts peak V/Sec GENERAL SPECIFICATIONS: (1) Parameter Operating Temperature Range Storage Temperature Range Maximum Turn-on Time (9) Maximum Turn-off Time (10) Input/Output Isolation (11) Input/Output to Base Isolation (11) Input/Output Capacitance (typical) Line Frequency Range Weight Interlocking Time All Devices -30 to 80°C -40 to 100°C 150 ms 1/2 cycle 4000 VAC 2500 VAC 8 pF 47 to 63 Hz 455 grams 100 mSec GAO THERMAL DISSIPATION CURVES THERMAL DISSIPATION 25 AMP GAO SERIES (ALL) 5° 50 1° C/ W 80 C/ W 40 90 2° C /W 30 100 3° C/W 20 110 10 120 NO HEATSINK 0 5 10 15 ON-STATE CURRENT (AMPS rms) 20 25 10 20 30 40 50 60 AMBIENT TEMPERATURE (°C) 70 80 BASEPLATE TEMPERATURE (°C) POWER DISSIPATION (WATTS) 70 0. Notes: (1) Specifications apply to each phase at an ambient temperature of -20 to 80°C unless otherwise noted. (2) Input is regulated and current limited. (3) Semiconductors rated at 1200 V. (4) See thermal dissipation/derating chart for heat sinking requirements. Catalog number PR250/100SE2 heat sink available separately for mounting GAO series SSR’s. (5) At maximum line voltage, 25°C. (6) One AC cycle maximum duration, non-repetitive, 25°C. (7) At rated output current, 25°C. (8) Minimum dv/dt per EIA/NARM RS443, method RS397, 25°C. (9) At minimum input voltage, maximum line voltage, rated output ourrent, 25°C. (10) At maximum input voltage, maximum line voltage, rated output current, 25°C. (11) At 25°C for 1 second maximum duration. Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-23 SOLID STATE RELAYS GA1, GA8, SERIES     High Current Thyristor for 100A Surge Capability UL Recognized/Horse Power Rated (GA8) (E46203) 4KV Optical Isolation     Zero Voltage Turn-On Industry Standard Packaging, SIP or Flat Pack Form A Output CE Compliant GA1 0.15 (3,8) 0.15 (3,8) 2(OUTPUT)1 1.2 (30,5) 1.5 (38,2) 1.1 (27,9) 4 (INPUT) 3+ 0.3 (7,6) 0.8 (20,3) 0.04 (1.0) DIA. TYP. 1.4 (35,6) 0.25 (6,4) 4 3 2 1 1.0 (25,4) 0.035 (,89) 0.245 (6,2) 0.375 (9,5) GA8 DIMENSIONS: inches (mm) TOLERANCE: ±0.020 (±0,50) 0.042 (1,1) DIA 1.7 (43,2) TRIGGER CIRCUIT 0.3 (7,6) 0.7 (17,8) 1 + SNUBBER 0.1 (2,5) 0.4 (10,2) 4 2 3 1.2 (30,5) 1.4 (35,5) DIMENSIONS: inches (mm) TOLERANCE: ±0.020 (±0,50) GA1 & GA8 SERIES DC INPUT EQUIVALENT CIRCUIT Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-18 SOLID STATE RELAYS GA1, GA8, SERIES 1 INPUT SPECIFICATIONS: (1) Parameter Minimum Turn-On Voltage Maximum Input Voltage Drop Out Voltage Maximum Input Current (2) Nominal Input Resistance (3) GA16B02 GA86B02 3.0 28 1.0 25 1K GA86D05 GA86D05R 3.0 28 1.0 25 1K Units VDC VDC VDC mADC  GA16B02 (10) GA86B02 GA86D05 GA86D05R Units 240 24 280 ±600 200 240 24 280 ±600 200 Vrms Vrms Vrms Vpeak V/S GA16B02 GA86B02 4.0 .05 100 1.6 GA86D05 GA86D05R 5.0 .05 100 1.6 Units Arms Arms Apeak Vpeak .1 1/4 .1 1/4 mArms H.P. All Devices -30 to +80 -40 to +100 .5 4000 8 47 to 63 Units °C °C Cycle Vrms pF Hz OUTPUT SPECIFICATIONS: Model Number Parameter Nominal Line Voltage Minimum Line Voltage Maximum Line Voltage Maximum Peak Off-State Voltage(4) Static (Off-State) dv/dt Parameter Maximum On-State Current (5) Minimum On-State Current Maximum 1-Cycle Surge (6) On-State Voltage Drop (7) Maximum Off-State Leakage (8) 240V Models HP Rating (11) GENERAL SPECIFICATION: (1) Parameter Operating Temperature Range Storage Temperature Range Response Time (12) Input to Output Isolation Voltage (9) Capacitance Input to Output (Typ) Line Frequency Range Note: GA1-2B and GA1-4B have been replaced by GA1-6B GA8-2B and GA8-4B have been replaced by GA8-6B 10 5 AMP. GA8 DERATING CURVE 9 8 A rms 7 6 5 AMP. Notes: (1) Specifications apply to Ta -30 TO +80 unless otherwise noted. (2) At maximum input voltage. (3) Does not include IRED impedance (drop). (4) One minute maximum duration when applied as a DC Voltage. (5) At Ta of 20°C, derate by 25 mA/°C to 40°C, 50 mA/°C from 40°C to 80°C. UL rating is 3.5 Arms, CSA rating is 3.0 Arms. (6) At Ta of 25°C, non-repetitive. (7) At Ta of 25°C and maximum on-state current. (8) At Ta of 25°C and maximum line voltage. (9) At Ta of 25°C, for one second. (10) Random turn-on versions available. Specify by adding suffix “R” to appropriate part number. Contact factory for additional details. (11) For GA8 only, 1/4 H.P. at 240 VAC, 1/8 HP at 120 VAC (12) AT 60 Hz 100 µS for Random Turn-on (suffix “R”) models 4 3 2 1 0 –30 –20 –10 0 10 20 30 40 50 TEMPERATURE DEGREE C 60 70 80 Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-19 SOLID STATE RELAYS THREE-PHASE SOLID STATE RELAYS  10, 25 and 45 Amps Output Per Channel Available  24 to 600 VAC Output Voltage Range Suitable for Many Applications  1200 Volts Peak Blocking Voltage Helps Protect Against Transients in Harsh Electrical Environments  Internal RC Snubber Network  4000 VAC Optical Isolation  4 to 32 Control Voltage for a Wide Variety of Logic Circuit Applications  Zero Voltage or Random Turn-on  Industry Standard Package  UL Recognized (E74183) 10 hp 480 VAC, CSA Certified (LR38545)  CE Compliant CURRENT LIMITER 1 A1+ U ZERO VOLTAGE DETECTOR OVER VOLTAGE PROTECTION S N U B B E R U ZERO VOLTAGE DETECTOR OVER VOLTAGE PROTECTION S N U B B E R 4 5 U ZERO VOLTAGE DETECTOR A2– OVER VOLTAGE PROTECTION OUTPUT INPUT 2 3 S N U B B E R 6 DIMENSIONS: INCHES (MILLIMETERS) TOLERANCE:+-0.020 ( +- 0,50) 0.73 (18,5) 0.88 (22,6) OUTPUT TERMINALS 4.0 mm (6) 4.09 (104,0) 0.3 (7,62) – + 4 6 1 3 5 2.89 (73,5) A2 0.2 (5,3) A1 1.87 (47,6) 2 INPUT TERMINALS 3.5 mm (2) 0.47 (12,1) 0.25 (6,35) 3.62 (92,0) Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-20 SOLID STATE RELAYS THREE-PHASE SOLID STATE RELAYS 1 INPUT SPECIFICATIONS: (1) Model Number GA312D10R GA312D10Z GA312D25R Parameter Voltage Range Drop Out Voltage Control Current (2) GA312D25Z GA312D45R GA312D45Z 4.0 to 32.0 VDC 1.0 VDC 20 mA GA312A25R GA312A25Z GA312A45R GA312A45Z 90-280 VAC 10 VAC 10 mA OUTPUT SPECIFICATIONS: (1) Model Number GA312D10R GA312D10Z GA312A25R GA312A25Z GA312D25R GA312D25Z GA312A45R GA312A45Z GA312D45R GA312D45Z Parameter Line Voltage Range SSR Maximum Peak Off-State Voltage (3) Rated Current (4) Minimum Current Maximum Off-State Leakage (5) One Cycle Surge Current (6) l2t Fusing Current Maximum On-State Voltage Drop (7) Off-State dv/dt (8) 24 to 660 1200 10 0.2 10.0 160 128 1.6 500 24 to 660 1200 25 0.2 10.0 270 365 1.6 500 24 to 660 1200 45 0.2 10.0 450 1000 1.6 500 GA312D10R GA312D25R GA312D45R GA312D10Z GA312D25Z GA312D45Z GA312A25R GA312A25Z GA312A45R GA312A45Z -30 to 80°C -40 to 100°C .20 8.33 4000 4000 8 47 to 63 450 -30 to 80°C -40 to 100°C 8.33 8.33 4000 4000 8 47 to 63 450 -30 to 80°C -40 to 100°C 20 30 4000 4000 8 47-63 450 Units VAC Vpeak Arms Arms mArms Apeak A2 Seconds Volts V/Sec GENERAL SPECIFICATIONS: (1) Parameter Operating Temperature Range Storage Temperature Range Maximum Turn-on Time (9) Maximum Turn-off Time (10) Input/Output Isolation (11) Input/Output to Base Isolation (11) Input/Output Capacitance (typical) Line Frequency Range Weight GA3 SERIES 3 PHASE SOLID STATE RELAY PART NUMBER SELECTION GUIDE OUTPUT RATING FUNCTION 10A 25A 45A GA312D10R GA312A25R GA312A45R GA312D25R GA312D45R Random Turn-on Zero Voltage Turn-on GA312D10Z GA312A25Z GA312A45Z GA312D25Z GA312D45Z UNITS °C °C mSec mSec VAC VAC pF Hz g Notes: (1) Specifications apply to each phase at an ambient temperature of -20 to 80°C unless otherwise noted. (2) Input is regulated and current limited. (3) 1000 V peak with Transorb® protection. Applying 1000V or greater will increase the off-state leakage and may result in relay failure if applied for longer than 1 second. (4) See thermal dissipation/derating chart for heat sinking requirements. Catalog number HS-7 heat sink available separately for mounting GA3 series SSR’s. (5) At 480 VAC line voltage, 25°C. (6) One AC cycle maximum duration, non-repetitive, 25°C. (7) At rated output current, 25°C. (8) Minimum dv/dt per EIA/NARM RS443, method RS397, 25°C. (9) At minimum input voltage, maximum line voltage, rated output ourrent, 25°C. (10) At maximum input voltage, maximum line voltage, rated output current, 25°C. (11) At 25°C for 1 second maximum duration. Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-21 SOLID STATE RELAYS GZ SERIES SSR FEATURES:       12 & 20 Amp AC Output Relays Low Profile Package Economical Triac Output 4000 VAC Optical Isolation Zero Crossing or Random Turn-On UL/cUL Recognized E46203 DIMENSIONS: DERATE CURVES: LOW CURRENT STANDARD GZ SSRs 12 AMP 12.0 11.5 11.0 10.5 Load Current (Amperes) 10.0 9.5 9.0 HEAT SINK RATINGS: 8.5 0.5°C/W 0.7°C/W 1.0°C/W 1.5°C/W 2.0°C/W 8.0 7.5 7.0 6.5 6.0 5.5 5.0 20 25 30 35 40 45 50 55 60 65 70 75 80 Ambient Temperature (°C) DERATE CURVES: HIGH CURRENT STANDARD GZ SSRs 20 AMP 20.0 19.0 18.0 WIRING: 17.0 16.0 1 4 TRIGGER HEAT SINK RATINGS: 14.0 13.0 0.5°C/W 0.7°C/W 1.0°C/W 1.5°C/W 2.0°C/W 12.0 11.0 10.0 CIRCUIT SNUBBER Load Current (Amperes) 15.0 + 3 2 Rc GZ SERIES DC INPUT EQUIVALENT CIRCUIT 9.0 8.0 7.0 6.0 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 Ambient Temperature (°C) Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-24 SOLID STATE RELAYS GZ SERIES SSR 1 INPUT SPECIFICATIONS: Model Number Parameter Control Voltage Drop Out Voltage Maximum Input Current (1) Maximum Turn-On Time Maximum Turn-Off Time Type Wire Size 84132000 84132010 84132400(9) 84132410(9) 84132100 84132110 84132500 84132510 4-15 1.0 32 8.33 8.33 Zero Crossing 4-15 1.0 32 0.1 8.33 Random Turn-On Units VDC VDC mA ms ms OUTPUT SPECIFICATIONS: Model Number Parameter Line Voltage Peak Off-State Voltage (2) Maximum Off-State Leakage (3) Static Off-State dv/dt Minimum On-State Current Maximum On-State Current (4) Maximum 1-Cycle Surge (5) Maximum 1-Second Surge (6) Peak On-State Voltage Drop (7) l2t (60 Hz, Half-Cycle) Rjb 84132000 84132100 84132010 84132110 84132400 84132500 84132410 84132510 24-280 600 0.1 250 0.1 12 120 36 1.65 50 3.0 24-280 600 0.1 250 0.1 20 200 60 1.55 50 2.2 36-530 800 0.1 250 0.1 12 120 36 1.65 50 3.0 36-530 800 0.1 250 0.1 20 200 60 1.55 50 2.2 Units Vrms Vpeak mArms V/Sec Arms Arms Apeak Apeak Vpeak A2 sec °C/W GENERAL SPECIFICATIONS: Parameter Operating Temperature Range Storage Temperature Range Input to Output Isolation Voltage (8) I/O to Ground Isolation Voltage (8) Capacitance (Input to Output) Line Frequency Range All Devices -20 to 80°C -40 to 100°C 4000 Vrms 2500 Vrms 8 pF 47 to 63 Hz Notes: (1) At 15Vdc. (2) Do not apply continuously for over 1 minute. (3) At maximum rated voltage. (4) Mounted in free air, Ta = 45°C. (5) Non-repetitive 60 Hz, Resistive load, Ta = 25°C. (6) Non-repetitive 50 or 60 Hz, Resistive load, Ta = 25°C. (7) At maximum rated current. (8) Limited to 1 mA for 1 second, Ta = 25°C. (9) Input current is 63 mA Max. Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-25 SOLID STATE RELAYS HS10 HEATSINK 1 2.362 ORDERING INFORMATION: Model # HS10 Description Heatsink 1.1°C/W (For Single Phase SSR’s) HS12 HEATSINK ORDERING INFORMATION: Model # HS12 Description Heatsink 0.55°C/W (For Single Phase SSR’s) DIMENSIONS: inches (mm) TOLERANCES: ±0.02 inches MATERIAL: AISI 6063-T5 Aluminum FINISH: Black Anodized Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-33 SOLID STATE RELAY ACCESSORIES HS1 HEATSINK 3.125 (79.38) 0.11 (2.8) DIA. 1.5 (38.1) 0.68 (17.5) MOUNTING HOLES FOR 4MM SCREW (4) 3.875 (98.43) DIMENSIONS: inches (mm) TOLERANCES: ±0.02 inches (±0.50) ORDERING INFORMATION: Model # HS1 Description Heatsink 1.5°C/W (For GA0 & GA3 Series SSR’s) 5.625 (142.88) HS2 HEATSINK 2.000 4.770 DIMENSIONS: inches TOLERANCES: ±0.02 inches MATERIAL: AISI 6063-T5 Aluminum FINISH: Black Anodized 4.450 ORDERING INFORMATION: Model # HS2 Description Heatsink 2.0°C/W (For Single Phase SSR’s) 0.201 2.000 3.00 0.50 0.16 #8-32 UNC FOR #8-32 SCREWS 4 PLACES Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-28 SOLID STATE RELAY ACCESSORIES HS3 HEATSINK 1 2.625 4.750 0.50 0.201 3.00 4.430 0.16 2.000 DIMENSIONS: inches TOLERANCES: ±0.02 inches MATERIAL: AISI 6063-T5 Aluminum FINISH: Black Anodized ORDERING INFORMATION: Model # HS3 Description Heatsink 1.5°C/W (For Single Phase SSR’s) #8-32 UNC FOR #8-32 SCREWS HS13 HEATSINK ORDERING INFORMATION: Model # HS13 Description Heatsink 0.8°C/W (For Single Phase and Three Phase SSR’s) DIMENSIONS: inches TOLERANCES: ±0.02 inches MATERIAL: AISI 6063-T5 Aluminum FINISH: Black Anodized Products and specifications subject to change without notice. Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1/31 SOLID STATE RELAY ACCESSORIES HS5 HEATSINK 2.630 4.750 DIMENSIONS: inches TOLERANCES: ±0.02 inches MATERIAL: AISI 6063-T5 Aluminum FINISH: Black Anodized 4.350 0.194 5.250 6.000 0.750 0.200 ORDERING INFORMATION: Model # HS5 Description Heatsink 0.7°C/W (For Single Phase SSR’s) #8-32 UNC HS6 HEATSINK FOR #8-32 SCREWS 4 PLACES 6.250 6.250 Model # HS6 Description Heatsink 0.5°C/W (For Single Phase SSR’s) 1.00 0.201 ORDERING INFORMATION: #8-32 UNC 6.00 6.050 0.10 4.000 DIMENSIONS: inches TOLERANCES: ±0.02 inches MATERIAL: AISI 6063-T5 Aluminum FINISH: Black Anodized FOR #8-32 SCREWS 4 PLACES Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-30 SOLID STATE RELAYS HS7 HEATSINK 2.84 [72.0] 3.70 [94.0] 1 .0125 [3.2] ORDERING INFORMATION: Model # HS7 4.094 [104.0] Description Heatsink 0.9°C/W (For GA3 Series SSR’s) 3.307 [84.0] 7.87[200.0] 6.89[175.0] 5.90[150.0] 5.59[142.0] 4.92[125.0] 3.94[100.0] 2.95[75.0] 1.97[50.0] 0.98[25.0] 0.0[0.0] 3.465[88.0] 1.88[47.7] M4 X 0.7(16)PLACES MOUNTING HOLE (4) DIMENSIONS: inches (mm) TOLERANCES: ±0.02 inches MATERIAL: AISI 6063-T5 Aluminum FINISH: Black Anodized Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-31 SOLID STATE RELAYS HS8 HEATSINK ORDERING INFORMATION: Model # HS8 Description Heatsink 2.1°C/W (For Single Phase SSR’s) HS9 HEATSINK ORDERING INFORMATION: Model # HS9 Description Heatsink 1.5°C/W (For Single Phase SSR’s) DIMENSIONS: inches (mm) TOLERANCES: ±0.02 inches MATERIAL: AISI 6063-T5 Aluminum FINISH: Black Anodized Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-32 SOLID STATE RELAYS “SMART MODULE” FEATURES:  Supplies Electrical And Visual Feedback If An Error Occurs In The Circuit Or With The Host SSR  4 to 32 VDC Push-Pull Transistor Alarm Output  4000 VAC Optical Isolation  1200 VAC Peak Off-State Blocking Voltage Allows For Use With Any DC Input G & GA5 Series SSR  UL/cUL Recognition Evaluation Pending  Mounts On Any Standard Puck Style SSR ELECTRICAL SPECIFICATIONS: (1) LINE VOLTAGE: INPUT: Nominal Voltage Maximum Voltage Minimum Voltage Off-State Voltage (2) 5-24 VDC 32 VDC 3 VDC 1 VDC Line Voltage Off-State Blocking Voltage (6) Off-State Leakage Current (7) DC SUPPLY/ERROR SIGNAL: Supply Voltage (3) Supply Current (4) Error Output Voltage (5) Error Output Current 24-660 Vrms 1200 Vpk 8 mArms GENERAL SPECIFICATIONS: 4-32 VDC 15-30 mA 4-32 VDC 30 mA Operating Temperature Storage Temperature Input To Output Isolation (8) Turn-On Time Turn-Off Time -20° to +80°C -40° to +100°C 4000 Vrms 8.3 mSec 8.3 mSec 1.1 (27,9) FUNCTION: (SMART MODULE ENERGIZED) 1.7 (43,2) 84060001 VDC IN STATUS INDICATOR SSR OUTPUT ERR ERR OUT ON OFF ON BLINKING ON (GREEN LED) NO INPUT TO SSR INPUT POWER TO SSR N/A ERROR (RED LED) NORMAL OPERATION INTERNAL SHORT EXTERNAL SHORT OR OPEN CIRCUIT 4-32VDC ERROR OUTPUT SIGNAL (DC SUPPLY) 0VDC (GROUND) 0VDC (GROUND) 1.0 (25,4) Notes: (1) Specifications apply to an ambient of -20° to + 80°C unless otherwise specified (2) Defined as the maximum allowable voltage on the input terminals of the SSR for the module to “sense” an off-state condition (3) Referenced to pin #4 (common) of the SSR (4) 30 mA max @ 32 VDC supply voltage; current regulated (5) During normal operation of the SSR; Error output = DC supply voltage (6) Maximum 1 minute duration (7) At maximum line voltage (8) At 25°C for 1 second Ordering Information Part Number: 84060001 Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-14 SOLID STATE RELAYS WIRING DIAGRAM: 1 Load AC Line (24 - 660 Vac) SOLID STA STATE RELAY RELAY Smartt Module Smar Error Output (2) (4-32 Vdc) DC Po Power Supply (2) (4-32 Vdc) Error Indicator Input Indicator Input (3-32 Vdc) (1) Ground (2) Note: Note: 1. G480D and G575D Series Series DC Input Range is 4-32 Vdc 1. HV GN Series DC Input Range is 4-32 Vdc 2. Input, Outputs and DC Po Power Supply 2. vInput, Outputs Supply oltages are refered refand eredDC to Power the same common Ground voltages are referred to the same common Ground Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-15 DC Solid State Relays GF Series; FET output - 10A, 15 A, 30A  Very low leakage current (< 10uA)  Milliohm On-Resistance Minimizes voltage drop, heat dissipation  1500 VAC Optical Isolation  UL/cUL recognized, Tuv approved, CE compliant IP20 GT Series; transistor output 10A Long Life Switching of DC loads  4 kV Optical Isolation  UL E46203  Available with IP20 “touch-safe” cover  IP00 Output Specifications Output Voltage range VDC Off-state leakage mA Output Current (Mounted on proper heat sink, see deratings) Minimum Current Max. 1 second surge current Max On-State Voltage Drop or On-State Resistance m Ohms Rjb (thermal res. Junction to baseplate, ºC/W) Minimum hear sink @ ambient (for max current = ºC/W & Ta) FET 1-200 0.01 10 FET 1-100 0.01 15 FET 1-50 0.01 30 TRAN 3-60 1.0 10 0.1 60 n/a 90 4.4 0.1 120 n/a 90 4.6 0.1 160 n/a 50 2.3 10 90 n/a n/a 4.3 3.0 @ 25ºc 3.0 @ 25ºC 1.0 @ 25ºC 1.0 @ 65ºC Part Numbers FET Output Rating 10 Amp 15 Amp 30 Amp Output 1-200Vdc 1-100Vdc 1-50Vdc Input 3-32Vdc 3-32Vdc 3-32Vdc IP00 84 134 850 84 134 860 84 134 870 IP20 84 137 850 84 137 860 84 137 870 3-32Vdc 84 134 750 84 137 750 Transistor Output 10 Amp 3-60Vdc Input Specifications Input voltage* Drop out voltage Max. input current (mA) Min. input current (for on-state) m Input Resistance Max. Turn-on time (mS) Max. Turn-off time (uS) 20 12 2 50 3-32Vdc 1Vdc 20 20 12 12 Current Regulated 2 2 50 50 14.5 9 .1 200 General Characteristics Operating Temperature (°C) Storage Temperature (°C) Input to output isolation Input/output to ground isolation Input to output capacitance Housing Material -20 to +80 -40 to +100 4000Vrms 2500Vrms 8pF (typical) UL 94V0 (self extinguishing) Safety and Noise Immunity Compliance CE Compliant with the LVD 73/23/EEC TUV EN60950 1 4 CONTROL CIRCUIT 3 + + 2 Rc GT SERIES EQUIVALENT CIRCUIT DC inductive loads must be diode suppressed to prevent damage to SSR 1 4 CONTROL CIRCUIT + 3 + CURRENT REGULATOR 2 GF SERIES EQUIVALENT CIRCUIT Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-16 Dual Solid State Relays    1 Output Specifications Part Numbers Voltage range (Vrms) Peak Voltage (Vpk, t = 1 min.) Off-state leakage mArms (@ max. line voltage & Ta = 25°C) Output Current (Mounted on proper heat sink, see deratings) Minimum Current (mArms) Max. 1 cycle surge current (Apk, Ta = 25°C) Max. 1 second surge current (Apk, Ta = 25°C) Forward voltage drop (Vpk @ Imax, Ta = 25°C) I2T (60Hz, 1/2 cycle) Rjb (thermal res. Junction to baseplate, °C/W) Static off-state dv/dt (Vµs, Ta = 25°C) 24 - 280Vac 550 0.1 24 - 280Vac 550 0.1 25 40 100 500 100 780 150 234 1.4 1.3 1041 0.6 2435 0.4 500 500 4-15Vdc 1Vdc 7.5mA 34mA 500 8.33msec 8.33msec 17-32Vdc 1Vdc 13mA 24mA 1500 8.33msec 8.33msec Input Specifications Input voltage Drop out voltage Min. input current (for on-state) Maximum input current Input Resistance (Ohms) Turn-on time* Turn-off time *Random SSR’s turn on in less than 100µs General Characteristics Operating Temperature (°C) Storage Temperature (°C) Input to output isolation Input/output to ground isolation Input to output capacitance Operating Frequency Housing Material -40 to +80 -40 to +100 4000Vrms 2500Vrms 8pF (typical) 47 to 63 Hz UL 94V0 (self extinguishing) Standards of Compliance CE Compliant with the LVD 73/23/EEC UL / cUL Recognized per UL 508 and CSA C22.2 no. 14-M91 Rating 25 Amp 25 Amp 40 Amp 40 Amp Rating 25 Amp 25 Amp 40 Amp 40 Amp 84 137 011 Zero Crossing Output Output Input 24-280Vac 4-15Vdc 24-280Vac 17-32Vdc 24-280Vac 4-15Vdc 24-280Vac 17-32Vdc Random Fire Output Output Input 24-280Vac 4-15Vdc 24-280Vac 17-32Vdc 24-280Vac 4-15Vdc 24-280Vac 17-32Vdc Part Number 84 140 000 84 140 010 84 140 200 84 140 210 Part Number 84 140 100 84 140 110 84 140 300 84 140 310 DERATE CURVE: 25 AMP GN Series Dual SSRs Ambient Temperature (°C) DERATE CURVE: 40 AMP GN Series Dual SSRs 1.131 ▲ 0.375 ▲ ▲ Ambient Temperature (°C) ▲  ▲ ▲  40 amp dual AC output relays Output voltage from 24 to 280 Vac Direct bond copper substrate Back to back dual SCR output 4000 Vac optical isolation Zero crossing or random turn on UL/cUL E79183, CE Compliant Combined Channel Output Current (Amperes)  Combined Channel Output Current (Amperes)  0.175 Mating Connector AMP #640441-4 ▲ ▲ ▲ 1.256 0.886 ▼ ▼ Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-17 GNA5 Series Solid State Relays       Current ratings 10 and 25 amps Output voltage 24 to 280 Vac Triac output Regulated AC and DC inputs 4000 Vac optical isolation UL E79183, CSA LR 38595, TUV Approved, CE Compliant Output Specifications 1 Part Numbers Voltage range (Vrms) Peak Voltage (Vpk, t = 1 min.) Off-state leakage (@ max. line voltage & Ta = 25°C) Output Current (Mounted on proper heat sink, see deratings) Minimum Current (mArms) Max. 1 cycle surge current (Apk, Ta = 25°C) Max. 1 second surge current (Apk, Ta = 25°C) Forward voltage drop (Vpk @ Imax, Ta = 25°C) I2T (60Hz, 1/2 cycle) Rjb (thermal res. Junction to baseplate, °C/W) Static off-state dv/dt (Vµs, Ta = 25°C) Minimum heat sink @ ambient (for max current = °C/W & Ta) 00 49 13 84 24 - 280Vac 600 0.10mArms 48 - 660Vac 1200 .25mArms 10 25 75 100 125 100 100 100 250 100 1000 100 1200 100 1700 30 75 225 300 375 1.5 1.3 1.3 1.3 1.3 41 2.2 240 1.7 5000 0.16 6000 0.155 12.041 0.15 500 500 500 500 500 3.0@ 40°C 1.0@ 40°C 0.7@ 40°C 0.6@ 40°C 0.4@ 40°C Input Specifications Rating 10 Amp Output 24-280Vac 25 Amp 24-280Vac Input 90-280Vac 3-32Vdc 90-280Vac 3-32Vdc 84 84 84 84 IP00 134 901 134 900 134 911 134 910 84 137 001 84 137 000 84 137 011 Quick connect terminals: 3/16" input and 1/4" output Rating Output Input IP00 10 Amp 24-280Vac 90-280Vac 84 134 905 3-32Vdc 84 134 904 25 Amp 24-280Vac 90-280Vac 84 134 915 3-32Vdc 84 134 914 Quick connect terminals: 1/4" input and 1/4" output Rating Output Input IP00 10 Amp 24-280Vac 90-280Vac 84 134 909 3-32Vdc 84 134 907 25 Amp 24-280Vac 90-280Vac 84 134 919 3-32Vdc 84 134 917 DIMENSIONS IN INCHES 90-280Vac 10Vrms 8.5mArms 5mArms 20ms 30ms 1/L1 4/A2 Input voltage* 3-32Vdc Drop out voltage 1Vdc Max. input current 14mA Min. input current (for on-state) 9.5mA Input Resistance Current Regulated Turn-on time** 8.33ms Turn-off time 8.33ms *4-32Vdc for 48-660Vac models **Random SSR’s turn on in less than 100µs General Characteristics -20 to +80 INPUT 2/T1 -40 to +100 4000Vrms 2500Vrms 8pF (typical) 47 to 63 Hz UL 94V0 (self extinguishing) 3/A1 Operating Temperature (°C) Storage Temperature (°C) Input to output isolation Input/output to ground isolation Input to output capacitance Operating Frequency Housing Material OUTPUT Safety and Noise Immunity Compliance CE Compliant with the LVD 73/23/EEC UL / cUL Recognized per UL 508 and CSA C22.2 no. 14-M91 E46203 TUV EN60950 IEC 61000-4-2: Electrostatic Discharge – Level 3 IEC 61000-4-3: Radiated Electromagnetic Noise – Level 3 IEC 61000-4-4: Electrically Fast Transients – Level 3 IEC 61000-4-5: Electrical Surges – Level 3 IEC 61000-4-6: Conducted Electromagnetic Noise – Level 3 IEC 61000-4-11 CISPR 11 – Class A: Allowable Levels of Conducted and Radiated Noise for Industrial Environments Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-11 GN Series Solid State Relays       Current ratings from 10 to 125 amps Output voltage from 24 to 660 Vac Back to back SCR’s for severe inductive loads Direct bond copper substrate Improved power lead frame design LED input status indicator     Transient protection built in 4000 Vac optical isolation Available with IP20 “touch-safe” cover UL E79183, CSA LR 38595, TUV Approved, CE Compliant Output Specifications Voltage range (Vrms) Peak Voltage (Vpk, t = 1 min.) Off-state leakage (@ max. line voltage & Ta = 25°C) 24 - 280Vac 600 .1mArms 0.1 48 - 660Vac 1200 .25mArms 0.25 25 50 75 100 125 50 300 100 750 100 1000 100 1200 100 1700 75 150 225 300 375 1.35 1.35 1.3 1.3 1.3 937 0.4 2458 0.25 5000 0.16 6000 0.155 12.041 0.15 500 500 500 500 500 1.5@ 50°C 1.0@ 40°C 0.7@ 40°C 0.6@ 40°C 0.4@ 40°C Rating 10 Amp 25 Amp Output 24-280Vac 24-280Vac 48-660Vac 50 Amp 24-280Vac 48-660Vac 75 Amp 24-280Vac 48-660Vac 100 Amp 24-280Vac 48-660 Input Specifications Input voltage* Drop out voltage Max. input current Min. input current (for on-state) Input Resistance Turn-on time** Turn-off time *4-32Vdc for 48-660Vac models **Random SSR’s turn on in less than 100µs 3-32Vdc 90-280Vac* 1Vdc 10Vrms 14mA 10mArms 7mA 5mArms Current Regulated 8.33ms 20ms 8.33ms 30ms 125 Amp -20 to +80 Safety and Noise Immunity Compliance CE Compliant with the LVD 73/23/EEC UL / cUL Recognized per UL 508 and CSA C22.2 no. 14-M91 TUV EN60950 IEC 1000-4-2: Electrostatic Discharge – Level 3 IEC 1000-4-3: Radiated Electromagnetic Noise – Level 3 IEC 1000-4-4: Electrically Fast Transients – Level 3 IEC 1000-4-5: Electrical Surges – Level 3 IEC 1000-4-6: Conducted Electromagnetic Noise – Level 3 CISPR 11 – Class A: Allowable Levels of Conducted and Radiated Noise for Industrial Environments Input 90-280Vac 3-32Vdc 90-280Vac 3-32Vdc 90-280Vac 3-32Vdc 90-280Vac 3-32Vdc 90-280Vac 3-32Vdc 90-280Vac 3-32Vdc 90-280Vac 3-32Vdc 90-280Vac 3-32Vdc 90-280Vac 3-32Vdc 90-260Vac 3-32Vdc 90-280Vac 3-32Vdc 90-280Vac 3-32Vdc 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 IP00 134 001 134 000 134 101 134 100 134 011 134 010 134 111 134 110 134 021 134 020 134 121 134 120 134 031 134 030 134 131 134 130 134 041 134 040 134 141 134 140 134 081 134 080 134 181 134 180 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 IP20 137 001 137 000 137 101 137 100 137 011 137 010 137 111 137 110 137 021 137 020 137 121 137 120 137 031 137 030 137 131 137 130 137 041 137 040 137 141 137 140 137 081 137 080 137 181 137 180 Input 3-32Vdc 3-32Vdc 3-32Vdc 3-32Vdc 3-32Vdc 3-32Vdc 3-32Vdc 3-32Vdc 3-32Vdc 3-32Vdc 3-32Vdc 3-32Vdc 84 84 84 84 84 84 84 84 84 84 84 84 IP00 134 200 134 300 134 210 134 310 134 220 134 320 134 230 134 330 134 240 134 340 134 280 134 380 84 84 84 84 84 84 84 84 84 84 84 84 IP20 137 200 137 300 137 210 137 310 137 220 137 320 137 230 137 330 137 240 137 340 137 280 137 380 Random SSR’s Rating 10 Amp 25 Amp -40 to +100 4000Vrms 2500Vrms 8pF (typical) 47 to 63 Hz UL 94V0 (self extinguishing) 24-280Vac 48-660Vac General Characteristics Operating Temperature (°C) Storage Temperature (°C) Input to output isolation Input/output to ground isolation Input to output capacitance Operating Frequency Housing Material IP00 Part Numbers (Zero Crossing) 48-660Vac Output Current (Mounted on 10 proper heat sink, see deratings) Minimum Current (mArms) 50 Max. 1 cycle surge current 150 (Apk, Ta = 25°C) Max. 1 second surge current 30 (Apk, Ta = 25°C) Forward voltage drop 1.35 (Vpk @ Imax, Ta = 25°C) 416 I2T (60Hz, 1/2 cycle) Rjb (thermal res. Junction to 0.5 baseplate, °C/W) Static off-state dv/dt 500 (Vµs, Ta = 25°C) Minimum heat sink @ ambient 3.0@ (for max current = °C/W & Ta) 70°C IP20 50 Amp 75 Amp 100 Amp 125 Amp Output 24-280Vac 48-660Vac 24-280Vac 48-660Vac 24-280Vac 48-660Vac 24-280Vac 48-660Vac 24-280Vac 48-660Vac 24-280Vac 48-660Vac Dimensions – see page 1-12 *For Ambient temperatures above 40°C the maximum control voltage must not exceed 250Vac. Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-10 DIMENSIONS IN INCHES 1/L1 4/A2 1/L1 4/A2 INPUT 2/T1 3/A1 2/T1 3/A1 OUTPUT DERATING CURVES DERATE CURVES: GN SSR-25 AMP TRIAC OUTPUT Load Current (Amperes) Load Current (Amperes) DERATE CURVES: GN SSR-10 AMP TRIAC OUTPUT Ambient Temperature (°C) Ambient Temperature (°C) Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-12 DERATE CURVES: GN SSR-25 AMP SCR OUTPUT (1200 & 600V) Load Current (Amperes) Load Current (Amperes) DERATE CURVES: GN SSR-10 AMP SCR OUTPUT 1 Ambient Temperature (°C) DERATE CURVES: GN SSR-50 AMP SCR OUTPUT (1200 & 600V) DERATE CURVES: GN SSR-75 AMP SCR OUTPUT (1200 & 600V) Load Current (Amperes) Load Current (Amperes) Ambient Temperature (°C) 0.5°C/W 0.7°C/W 1.0°C/W 1.5°C/W Ambient Temperature (°C) DERATE CURVES: GN SSR-100 AMP SCR OUTPUT (1200 & 600V) DERATE CURVES: GN SSR-125 AMP SCR OUTPUT (1200 & 600V) Load Current (Amperes) Load Current (Amperes) Ambient Temperature (°C) Ambient Temperature (°C) Ambient Temperature (°C) Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-13 280 VOLT DUAL SOLID STATE RELAYS 40 amp dual AC output relays Output voltage from 24 to 280 Vac Direct bond copper substrate Back to back dual SCR output 4000 Vac optical isolation Zero crossing or random turn on UL/cUL Recognized, CE Compliant Part Numbers 25 40 100 500 100 780 150 234 1.4 1.3 1250 0.6 2435 0.4 500 500 4-15Vdc 1Vdc 7.5mA 34mA 500 8.33msec 8.33msec 17-32Vdc 1Vdc 13mA 24mA 1500 8.33msec 8.33msec Input Specifications Input voltage Drop out voltage Min. input current (for on-state) Maximum input current Input Resistance (Ohms) Turn-on time* Turn-off time QC, Mated/Locking Input 24-280Vac 550 0.1 QC, Standard Input Pins Output Specifications Voltage range (Vrms) Peak Voltage (Vpk , t = I min.) Off-state leakage mArms (@ max. line voltage & Ta = 25ºC) Output Current (Mounted on proper heat sink, see deratings) Minimum Current (mArms) Max. 1 cycle surge current (Apk, Ta = 25ºC) Max. 1 second surge current (Apk, Ta = 25ºC) Forward voltage drop (Vpk @ Imax, Ta = 25ºC) I2T (60Hz, ½ cycle) Rjb (thermal res. Junction to baseplate, ºC/W) Static off-state dv/dt (Vµs, Ta = 25ºC) * Random SSR's turn on in less than 100µs -40 to + 80 -40 to + 100 4000Vrms 2500Vrms 8pF (typical) 47 to 63 Hz UL 94V0 (self extinguishing Standards of Compliance CE Compliant with the LVD 73/23/EEC UL / cUL Recognized per UL 508 and CSA C22.2 no. 14-M91 Standard Input Pins General Characteristics Operating Temperature (ºC) Storage Temperature (ºC) Input to output isolation Input/output to ground isolation Input to output capacitance Operating Frequency Housing Material 1/4" Quick Connect Zero Crossing Output Rating Output Input Part Number 25 Amp 24-280Vac 4-15Vdc 84140000 25 Amp 24-280Vac 17-32Vdc 84140010 40 Amp 24-280Vac 4-15Vdc 84140200 40 Amp 24-280Vac 17-32Vdc 84140210 Random Fire Output Rating Output Input Part Number 25 Amp 24-280Vac 4-15Vdc 84140100 25 Amp 24-280Vac 17-32Vdc 84140110 40 Amp 24-280Vac 4-15Vdc 84140300 40 Amp 24-280Vac 17-32Vdc 84140310 Locking Connector Part Numbers Zero Crossing Output Rating Output Input Part Number 25 Amp 24-280Vac 4-15Vdc 84140800 25 Amp 24-280Vac 17-32Vdc 84140810 40 Amp 24-280Vac 4-15Vdc 84140900 40 Amp 24-280Vac 17-32Vdc 84140910 Random Fire Output Rating Output Input Part Number 25 Amp 24-280Vac 4-15Vdc 84140801 25 Amp 24-280Vac 17-32Vdc 84140811 40 Amp 24-280Vac 4-15Vdc 84140901 40 Amp 24-280Vac 17-32Vdc 84140911 Mating Connector: Molex # 14-56-2042 Screw Terminals Part Numbers Zero Crossing Output Rating Output Input Part Number 25 Amp 24-280Vac 4-15Vdc 84140003 25 Amp 24-280Vac 17-32Vdc 84140013 40 Amp 24-280Vac 4-15Vdc 84140203 40 Amp 24-280Vac 17-32Vdc 84140213 Random Fire Output Rating Output Input Part Number 25 Amp 24-280Vac 4-15Vdc 84140103 25 Amp 24-280Vac 17-32Vdc 84140113 40 Amp 24-280Vac 4-15Vdc 84140303 40 Amp 24-280Vac 17-32Vdc 84140313 See next page thermal curves. Mating Connector for 841408xxx and 841409xxx Molex # 14-56-2042 Products and specifications subject to change without notice Order/Technical Support - Tel: (800) 677-5311 / Fax: (800) 677-3865 / www.crouzet-usa.com 660 VOLT DUAL SOLID STATE RELAYS 40 amp dual AC output relays Output voltage from 48 to 660 Vac Direct bond copper substrate Back to back dual SCR output 4000 Vac optical isolation Zero crossing or random turn on UL/cUL Recognized, CE Compliant Part Numbers 25 40 100 500 100 780 150 234 1.4 1.3 1250 0.6 2435 0.4 500 500 4-15Vdc 1Vdc 7.5mA 34mA 500 8.33msec 8.33msec 17-32Vdc 1Vdc 13mA 24mA 1500 8.33msec 8.33msec Input Specifications Input voltage Drop out voltage Min. input current (for on-state) Maximum input current Input Resistance (Ohms) Turn-on time* Turn-off time Standard Input Pins 48-660Vac 1000 0.25 QC, Standard Input Pins Output Specifications Voltage range (Vrms) Peak Voltage (Vpk , t = I min.) Off-state leakage mArms (@ max. line voltage & Ta = 25ºC) Output Current (Mounted on proper heat sink, see deratings) Minimum Current (mArms) Max. 1 cycle surge current (Apk, Ta = 25ºC) Max. 1 second surge current (Apk, Ta = 25ºC) Forward voltage drop (Vpk @ Imax, Ta = 25ºC) I2T (60Hz, ½ cycle) Rjb (thermal res. Junction to baseplate, ºC/W) Static off-state dv/dt (Vµs, Ta = 25ºC) 1/4" Quick Connect Zero Crossing Output Rating Output Input Part Number 25 Amp 48-660Vac 4-15Vdc 84140500 25 Amp 48-660Vac 17-32Vdc 84140510 40 Amp 48-660Vac 4-15Vdc 84140600 40 Amp 48-660Vac 17-32Vdc 84140610 Random Fire Output Rating Output Input Part Number 25 Amp 48-660Vac 4-15Vdc 84140501 25 Amp 48-660Vac 17-32Vdc 84140511 40 Amp 48-660Vac 4-15Vdc 84140601 40 Amp 48-660Vac 17-32Vdc 84140611 Screw Terminals Part Numbers Zero Crossing Output Rating Output Input Part Number 25 Amp 48-660Vac 4-15Vdc 84140503 25 Amp 48-660Vac 17-32Vdc 84140513 40 Amp 48-660Vac 4-15Vdc 84140603 40 Amp 48-660Vac 17-32Vdc 84140613 Random Fire Output Rating Output Input Part Number 25 Amp 48-660Vac 4-15Vdc 84140530 25 Amp 48-660Vac 17-32Vdc 84140531 40 Amp 48-660Vac 4-15Vdc 84140630 40 Amp 48-660Vac 17-32Vdc 84140631 * Random SSR's turn on in less than 100µs General Characteristics Operating Temperature (ºC) Storage Temperature (ºC) Input to output isolation Input/output to ground isolation Input to output capacitance Operating Frequency Housing Material -40 to + 80 -40 to + 100 4000Vrms 2500Vrms 8pF (typical) 47 to 63 Hz UL 94V0 (self extinguishing) Standards of Compliance CE Compliant with the LVD 73/23/EEC UL / cUL Recognized per UL 508 and CSA C22.2 no. 14-M91 Products and specifications subject to change without notice Order/Technical Support - Tel: (800) 677-5311 / Fax: (800) 677-3865 / www.crouzet-usa.com