Transcript
Soluciones de Gabinetes de TI de Schneider Electric: La oferta más completa del mercado
Presented by: Víctor Acosta
Confidential Property of Schneider Electric
Agenda
NetShelter SX NetShelter CX NetShelter VX Spacial
Micro Data Centers
Confidential Property of Schneider Electric | Page 2
NetShelter SX
Confidential Property of Schneider Electric | Page 3
NetShelter SX
NetShelter SX is the building block of power and cooling InfraStruxure
Available in 24U, 42U, 45U and 48U heights, 600mm and 750mm widths, and 1070mm and
1200mm depths • Agility ‒ Offering the most standard features to ease installation and speed deployment. ‒ Single rack design is flexible to accommodate various networking and server applications and now AV and Colocation environments.
• Compatibility ‒ Cooling, rack power distribution, and cable management products work seamlessly with the enclosures.
‒ Guaranteed compatibility with any EIA-310-E compliant IT equipment.
Confidential Property of Schneider Electric | Page 4
NetShelter SX
SX Enclosures: Key Considerations
• •
Enclosures are often the defining product in the data center infrastructure
•
The majority of servers worldwide are mounted within enclosures
• •
Confidential Property of Schneider Electric | Page 5
NetShelter SX enclosures are the building block to the entire InfraStruxure product offering
Enclosures provide increased strength, security, and airflow control as compared to open frame racks Large increases in cable densities due to server compaction and networking architecture drives the need for larger enclosures and more cable management space
NetShelter SX
NetShelter SX Differentiators
1 5
Features 1
Cable Access Roof • Eight cable entry slots • Toolless mounting of overhead cable trough system • Snap-in mounting for allow easy roof removal and installation with cables in place
2
More Standard Features -> Faster Installation
2 Integrated Baying Brackets • Pre-Installed on frame front and back • Spacing Options at 24 in or 600 mm • Bays with other InfraStruxure power and cooling products
4
3 Pre-installed Levelling Feet and Casters
4
Toolless, Zero U Accessory Channel • Toollessly mount PDUs • Toollessly mount vertical cable organizers • New cable fastening features
• Easily adjustable levelling from top down • Casters standard on all enclosures
6
5 Easily Adjustable Vertical Mounting Rails • Simple screw and cam engagement • Captive screws - No loose hardware • Easy visual alignment for quick adjustment • ¼ inch increments through enclosure
Confidential Property of Schneider Electric | Page 6
Half-Height Side Panels
6
• • • •
Easy and safe handling Quick release latch Lockable - same key as doors Enclosure width the same with or without sides installed
3
Heights – 24U, 42U, 45U, 48U Widths – 600mm ( 24”), 750mm (30”) Depths – 1070mm (42”), 1200mm (47.5”)
NetShelter SX: Ease of Use Features Rear cabling channels + multi-purpose mounting
NetShelter SX Enclosures Sizes optimized to cover a wide range of applications
Applications For Depth
Applications For Height
Applications For Width
White NetShelter SX Enclosures – NAM Only The same standard NetShelter SX features available in a brighter color NetShelter SKU Height Width Depth Application AR3100W 42U 600mm (24in) 1070mm (42in) Low-Med Density Servers AR3105W 45U 600mm (24in) 1070mm (42in) Low-Med Density Servers AR3300W 42U 600mm (24in) 1200mm (47.5in) Med-High Density Servers AR3305W 45U 600mm (24in) 1200mm (47.5in) Low-Med Density Servers AR3307W 48U 600mm (24in) 1200mm (47.5in) Med-High Density Servers
AR3150W
42U
750mm (30in) 1070mm (42in)
Networking and Blade Applications
AR3155W
45U
750mm (30in) 1070mm (42in)
Networking and Blade Applications
AR3350W
42U
750mm (30in) 1200mm (47.5in) Networking and Blade Applications
AR3355W AR3140W AR3340W
45U 42U 42U
750mm (30in) 1070mm (42in) Networking and Blade Applications 750mm (30in) 1070mm (42in) Very High Density Networking 750mm (30in) 1200mm (47.5in) Very High Density Networking
Grey NetShelter SX Enclosures – EMEA Only The same standard NetShelter SX features available in a brighter color NetShelter SKU Height AR3100G 42U AR3300G 42U AR3307G 48U
Width 600mm 600mm 600mm
Depth 1070mm 1200mm 1200mm
Application Low-Med Density Servers Med-High Density Servers Med-High Density Servers
AR3180G
42U
800mm
1070mm
Networking and Blade Applications
AR3380G AR3140G AR3340G
42U 42U 42U
800mm 750mm 750mm
1200mm 1070mm 1200mm
Networking and Blade Applications Very High Density Networking Very High Density Networking
NetShelter SX Accessories Cable Management Extensive line of options for supporting patch cables and available in multiple styles for server and networking applications.
Overhead Cable Management Integrated system of cable troughs, partitions, and ladders to attach to the top the enclosures
Air-flow Management Accessories for isolating bypass air with the enclosure and through the raised floor
Shelving Fixed and sliding shelves with weight capacities ranging from 50-250 lbs. (23-113 kg)
Stabilization Bolt-down brackets for floor anchoring, with anti-tip plate for stand-alone applications
NetShelter SX Networking Maintains the NetShelter design and compatibility while offering improved networking application support (AR3140, AR3340, AR3347, AR3140W, AR3340W)
AR3140 42U 750mm W 1070mm D
AR3340 42U 750mm W 1200mm D
AR3347 48U 750mm W 1200mm D
Global Availability
AR3140W 42U 750mm W 1070mm D
AR3340W 42U 750mm W 1200mm D
NAM Only
AR3140G 42U 750mm W 1070mm D
AR3340G 42U 750mm W 1200mm D
EMEA Only
High Density Networking Examples
Cisco Catalyst 6500 Series – AR3140 Enclosure and AR7715 Side Airflow Duct kits
Cisco Nexus 7018 – AR3340 Enclosure and AR7742 Side Airflow Duct kit
Enclosure Design Networking Enclosure Integrated Vertical Cable Management Front vertical mounting rails have preinstalled 6” cable guides. Front left vertical mounting rail features an integrated cable channel behind the rail. – Provides additional cable capacity – Acts as air block for exhaust air from switch
Integrated cable channel behind rail
NetShelter SX Networking Roof Designed for easy cable access for large cable bundles and toolless installation & removal (1070mm version roof shown)
Roof shape is optimized for networking configurations Incorporates large open areas for cable entry/exit from enclosure Modular brush sections are used for air containment and aesthetics Utilizes existing toolless mounting and over head trough hole pattern
Large cable access slots for bundles of data cable
Networking Rack Applications 1-2 Cisco 6509 switch & patching (AR3140 shown) Cisco recommends routing cable to the right to avoid blocking fan tray (for maintenance)
Up to 576 Cat6 cables
Up to 288 Cat6 cables 42 42
42
42
42
41
41
42
42
42
41
41
41
WS-X6548-GE-TX
1
11 2
1314
23 24
12
25
35 26
3738
41
47
36
48
1
41
41
40
40
40
40
39
39
39
39
38
38
40
WS-X6548-GE-TX
38
1
2
3
4
5
6
7
1
2
3
4
5
6
7
8
8
9
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
10
11
12
1
13
11 2
14
15
16
17
18
19
20
21
22
23
24
1314
23 24
12
SWITCHING MODULE 25
26
27
28
29
30
31
32
33
34
37
35
38
39
40
41
42
43
44
45
46
48
47
3738
26
40
47
36
39
10/100/1000 BASE-T ETHERNET
48 PORT
STATUS
WS-X6548-GE-TX
1
11 2
13
14
15
16
17
18
19
20
21
22
23
24
48
13
14
15
16
17
18
19
20
21
22
23
24
1314
23 24
12
SWITCHING MODULE 25
26
27
28
29
30
31
32
33
34
35
36
25
26
27
28
29
30
31
32
33
34
35
36
25
35
38
39
40
41
42
43
44
45
46
47
48
37
38
39
40
41
42
43
44
45
46
47
48
3738
26
39
47
36
10/100/1000 BASE-T ETHERNET
48 PORT
STATUS
48
SWITCHING MODULE
38
MGMT
4
ATUS
VE SYSTEM ACTI
PWR
CONSOLE
PORT 1
DISK 0
PORT 2
PORT 3
PORT 4
PORT 5
PORT 6
PORT 7
38
PHONE
WS- SUP 32- GE - 3B
38 37
39
PHONE
37
3
38
40
PHONE
36
35
25
2
ST
38
10/100/1000 BASE-T ETHERNET
48 PORT
STATUS
40 39
PORT 8
USB 2.0
RESET
PORT 9
SUPERVISOR ENGINE 32
EJECT
LINK
LI
NK
LINK
LI
K
NK
LIN
LI
NK
LI
NK
37
K LIN LINK
WS- SUP 32- GE - 3B
37
37
37
37
37
ST
ATUS
VE ACTI
SYST
PWR
CONSOLE
36
36
36
36 35
35
35 34
34
34
33
33
33
33
32
32
32
32
31
31
31
31
30
30
30
30
29
29
29
29
28
28
28
28
27
27
27
27
26
26
26
26
25
25
25
25
24
24
24
24
23
23
23
23
22
22
22
22
21
21
21
21
20
20
20
20
19
19 WS-X6548-GE-TX
19
1
11 2
1314
23 24
12
25
35 26
3738
19
47
36
48
1
18
1
18
WS-X6548-GE-TX
10/100/1000 BASE-T ETHERNET
48 PORT
STATUS 2
3
4
5
6
7
8
9
10
11
12
1
13
11 2
14
15
16
17
18
19
20
21
22
23
24
1314
23 24
12
SWITCHING MODULE 25
26
27
28
29
30
31
32
33
34
37
25
35
38
39
40
41
42
43
44
45
46
48
47
3738
26
18
47
36
48
2
17
10/100/1000 BASE-T ETHERNET
48 PORT
STATUS 1
WS-X6548-GE-TX
17
2
3
4
5
6
7
8
9
10
11
12
1
13
11 2
14
15
16
17
18
19
20
21
22
23
24
1314
23 24
12
SWITCHING MODULE 25
26
27
28
29
30
31
32
33
34
37
35
38
39
40
41
42
43
44
45
46
48
47
3738
26
17
PHONE
36
35
25
18
PHONE
36
35
17
47
36
48
3
PORT 3
PORT 4
PORT 5
PORT 6
PORT 7
PORT 8
USB 2.0 PORT 9
LIN
LI
NK
LINK
LI
NK
LI
NK
LI
NK
LI
NK
LI
NK
36
K LIN
WS-X6548-GE-TX
36
1
11
1314
25
35 26
3738
47
36
48
36 1
2
3
4
5
6
7
8
9
10
35 WS-X6548-GE-TX
35
10/100/1000 BASE-T ETHERNET
48 PORT
STATUS 11
12
1
13
11
14
15
16
17
18
19
20
21
22
23
24
1314
23 24
12
SWITCHING MODULE 25
26
27
28
29
30
31
32
33
34
PHONE
36
35
37
25
35
38
39
40
41
42
43
44
45
46
48
47
35
3738
26
47
36
48
35
7
WS-X6548-GE-TX
34
10/100/1000 BASE-T ETHERNET
48 PORT
STATUS
34
1
2
3
4
5
6
1
2
3
4
5
6
7
8
9
10
11
12
1
13
11
14
15
16
17
18
19
20
21
22
23
24
1314
23 24
12
SWITCHING MODULE 25
26
27
28
29
30
31
32
33
34
PHONE
36
35
25
37
35 26
38
39
40
41
42
43
44
45
46
34
48
47
3738
47
36
48
34
8
10/100/1000 BASE-T ETHERNET
48 PORT
STATUS
33
23 24
12
6
2
34
PORT 2
K
EJECT
2
35
PORT 1
DISK 0
RESET
SUPERVISOR ENGINE 32
2
36
37
MGMT EM
5
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
SWITCHING MODULE 25
26
27
28
29
30
31
32
33
34
PHONE
36
35
37
38
39
40
41
42
43
44
45
46
48
47
33
STATUS
33
33
9
32
32
32
32
31
INPUT 1 100-240 V ~ 16A 60/50 Hz
31
31
INPUT 1 100-240 V ~ 16A 60/50 Hz
31
30
30 0
30 29
0
INPUT 2 100-240 V ~ 16A 60/50 Hz
29
29
L
TAL INS RUN
TAL INS RUN
INPUT OK
28
28
30
INPUT 2 100-240 V ~ 16A 60/50 Hz
L
1
Cisco Systems, Inc.
FAN OK
INPUT OK
2
1
Cisco Systems , Inc.
SWITCH MUST BE IN OFF "O" POSITION TO INSTALL/ REMOVE POWER SUPPLY. FASTENER MUST BE FULLY ENAGED PRIOR TO OPERATING POWER SUPPLY.
27
29
OUTPUT FAIL
FAN OK
OUTPUT FAIL
28
2
28
SWITCH MUST BE IN OFF "O" POSITION TO INSTALL/ REMOVE POWER SUPPLY. FASTENER MUST BE FULLY ENAGED PRIOR TO OPERATING POWER SUPPLY.
Power Supply 1
27
Power Supply 2
27
27
26
26
26
26
25
25
25
25
24
24
24
24
23
23
23
23
22
22
22
22
21
21
21
21
20
20
20
20
19
19 WS-X6548-GE-TX
19
1
11 2
1314
23 24
12
25
35 26
3738
19
47
36
48
1
18
10/100/1000 BASE-T ETHERNET
48 PORT
STATUS 1
18
WS-X6548-GE-TX
2
3
4
5
6
7
8
9
10
11
12
1
13
11 2
14
15
16
17
18
19
20
21
22
23
24
1314
23 24
12
SWITCHING MODULE 25
26
27
28
29
30
31
32
33
34
37
35
38
39
40
41
42
43
44
45
46
48
47
3738
26
17
18
47
36
10/100/1000 BASE-T ETHERNET
48 PORT
STATUS
WS-X6548-GE-TX
17
48
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
1
11 2
13
14
15
16
17
18
19
20
21
22
23
24
13
14
15
16
17
18
19
20
21
22
23
24
1314
23 24
12
SWITCHING MODULE 25
26
27
28
29
30
31
32
33
34
35
36
25
26
27
28
29
30
31
32
33
34
35
36
25
35
38
39
40
41
42
43
44
45
46
47
48
37
38
39
40
41
42
43
44
45
46
47
48
17
47
36
10/100/1000 BASE-T ETHERNET
48 PORT
STATUS
17
PHONE
37
3738
26
48
3
16
18
PHONE
36
35
25
2
SWITCHING MODULE
16
PHONE
WS- SUP 32- GE - 3B
16
10/100/1000 BASE-T ETHERNET
48 PORT
STATUS 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
SWITCHING MODULE 25
26
27
28
29
30
31
32
33
34
36
35
16
PHONE
37
38
39
40
41
42
43
44
45
46
48
47
16
VE STATUS SYSTEM ACTI
15
16
MGMT
4
PWR
CONSOLE
PORT 1
DISK 0
PORT 2
PORT 3
PORT 4
PORT 5
PORT 6
PORT 7
PORT 8
USB 2.0
RESET
PORT 9
ATUS
ST
SUPERVISOR ENGINE 32
EJECT
LINK
LI
NK
LINK
LI
K
NK
LIN
LI
NK
LI
NK
K
15
LIN LINK
WS- SUP 32- GE - 3B
15
15
MGMT VE
5
STATUS SYSTEM ACTI
PWR
CONSOLE
PORT 2
PORT 3
PORT 4
PORT 5
PORT 6
PORT 7
PORT 8
USB 2.0 PORT 9
SUPERVISOR ENGINE 32
14
PORT 1
DISK 0
RESET
K
EJECT
LIN
LI
NK
LINK
LI
NK
LI
NK
LI
NK
LI
NK
LI
NK
K
14
LIN
WS-X6548-GE-TX
1
11 2
14
1314
23 24
12
25
35 26
3738
47
36
48
14
6 10/100/1000 BASE-T ETHERNET
48 PORT
STATUS 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
SWITCHING MODULE 25
26
27
28
29
30
31
32
33
34
VE SYSTEM ACTI
PWR
CONSOLE
PORT 1
DISK 0
PORT 2
PORT 3
PORT 4
PORT 5
PORT 6
PORT 7
PORT 8
USB 2.0
RESET
PORT 9
37
38
39
40
41
42
43
44
45
46
1
11 2
1314
23 24
12
25
35 26
3738
47
36
48
13
7
1
WS-X6548-GE-TX
2
3
4
5
6
7
8
9
10
11
12
1
13
11 2
12
10/100/1000 BASE-T ETHERNET
48 PORT
STATUS
12
14
15
16
17
18
19
20
21
22
23
24
1314
23 24
12
SWITCHING MODULE 25
26
27
28
29
30
31
32
33
34
PHONE
36
35
25
37
35 26
38
39
40
41
42
43
44
45
46
12
48
47
3738
47
36
48
12
8
48 PORT
STATUS 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
10/100/1000 BASE-T ETHERNET
SWITCHING MODULE 25
26
27
28
29
30
31
32
33
34
35
37
38
39
40
41
42
43
44
45
46
47
48
11
11
11
9
10
10
10
10
9
INPUT 1 100-240 V ~ 16A 60/50 Hz
9
LINK
LI
NK
LINK
LI
K
NK
LIN
LI
NK
LI
NK
K LINK
15
ST
ATUS
VE ACTI
SYST
PWR
CONSOLE
PORT 1
DISK 0
PORT 2
PORT 3
PORT 4
PORT 5
PORT 6
PORT 7
PORT 8
9
PORT 9
K
EJECT
LIN
LI
NK
LINK
LI
NK
LI
NK
LI
NK
LI
NK
LI
7
7
1
11 2
14
1314
23 24
12
25
35 26
6
6 5
Cisco Systems, Inc.
1
FAN OK
48
14
6 10/100/1000 BASE-T ETHERNET
48 PORT
STATUS 1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
SWITCHING MODULE 25
26
27
28
29
30
31
32
33
34
13
37
2
SWITCH MUST BE IN OFF "O" POSITION TO INSTALL/ REMOVE POWER SUPPLY. FASTENER MUST BE FULLY ENAGED PRIOR TO OPERATING POWER SUPPLY. Power Supply 1
5
Cisco Systems , Inc.
1
FAN OK
OUTPUT FAIL
2
SWITCH MUST BE IN OFF "O" POSITION TO INSTALL/ REMOVE POWER SUPPLY. FASTENER MUST BE FULLY ENAGED PRIOR TO OPERATING POWER SUPPLY.
1
11
1314
23 24
12
25
35 26
40
41
42
43
44
45
46
48
47
3738
47 48
13 WS-X6548-GE-TX
7
8
9
10
11
12
1
13
11 2
12
14
15
16
17
18
19
20
21
22
23
24
1314
23 24
12
SWITCHING MODULE 25
26
27
28
29
30
31
32
33
34
PHONE
36
35
25
37
35 26
38
39
40
41
42
43
44
45
46
48
47
3738
12
47
36
48
12
8
48 PORT
STATUS 7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
10/100/1000 BASE-T ETHERNET
SWITCHING MODULE 25
26
27
28
29
30
31
32
33
34
35
PHONE
36
37
38
39
40
41
42
43
44
45
46
47
48
STATUS
11
11
11
11
9
10
10
10
10
9
INPUT 1 100-240 V ~ 16A 60/50 Hz
9
9
INPUT 1 100-240 V ~ 16A 60/50 Hz
9 8
8 7
5 5
Power Supply 2
5
3
2
2
1
1
1
FAN OK
7
7
OUTPUT FAIL
2
SWITCH MUST BE IN OFF "O" POSITION TO INSTALL/ REMOVE POWER SUPPLY. FASTENER MUST BE FULLY ENAGED PRIOR TO OPERATING POWER SUPPLY. Power Supply 1
INPUT OK
Cisco Systems , Inc.
1
FAN OK
OUTPUT FAIL
2
SWITCH MUST BE IN OFF "O" POSITION TO INSTALL/ REMOVE POWER SUPPLY. FASTENER MUST BE FULLY ENAGED PRIOR TO OPERATING POWER SUPPLY.
6
6 5
Power Supply 2
5
5
4
4
3
3
2
2
1
1
4
3
2 2
1
Cisco Systems, Inc.
8
INPUT 2 100-240 V ~ 16A 60/50 Hz
L TAL INS RUN
3 3
2
INPUT 2 100-240 V ~ 16A 60/50 Hz
4
4
3
0
L TAL INS RUN
INPUT OK
6
6
4
3
39
36
10/100/1000 BASE-T ETHERNET
48 PORT
STATUS
6
6
4
4
38
7
12
7
INPUT OK
PHONE
36
35
13 WS-X6548-GE-TX
7
7
OUTPUT FAIL
14 47
8
8
L TAL INS RUN
INPUT OK
K
3738 36
13
0 INPUT 2 100-240 V ~ 16A 60/50 Hz
L TAL INS RUN
NK LIN
WS-X6548-GE-TX
0
0
USB 2.0
RESET
SUPERVISOR ENGINE 32
8 INPUT 2 100-240 V ~ 16A 60/50 Hz
15
MGMT EM
5
14
9
INPUT 1 100-240 V ~ 16A 60/50 Hz
8
8
15
LIN
PHONE
36
STATUS
11
EJECT
WS- SUP 32- GE - 3B
2
48
47
13 WS-X6548-GE-TX
SUPERVISOR ENGINE 32
PHONE
36
35
13
13
15
16
MGMT
4
WS- SUP 32- GE - 3B
16
2
1 1
1
NetShelter SX Colocation Maintains the NetShelter design and compatibility while offering additional security features essential for colocation facilities with secure environments for multiple tenants (AR3200)
42U x 600mm
NetShelter SX Colocation Enclosure Features ● Two 20U compartments
● Top and bottom mounting rails adjust independently
● 600mm (24”) W x 1070mm (42”) D
● Combination locks
on front and rear doors
● Vertical 0U
accessory channel for mounting cable managers and Rack PDUs
● Secure center divider
● Side Panels included ● Includes casters
and leveling feet
● Quick release doors
Front View
NetShelter AV Designed specifically for the professional AV market – 825mm deep (AR38xx)
24U x 600mm
42U x 600mm
42U x 600mm (no sides/roof/doors)
NetShelter AV: Environments ●Broadcast ●Command/CC ●Theme Parks ●Theater/Stadiums ●Churches/Schools ●High end residential ●Restaurants ●Commercial security ●IT Crossover ● Commercial security ● High end residential ● Broadcast
CONDUIT AND CABLE ACCESS ROOF
NetShelter AV Features
> Four removable conduit access panels with holes varying in size and two cable access slots with brush strips for air containment > Two spring loaded pins allow for easy roof removal and installation with cables in place
ADJUSTABLE 10-32 THREADED MOUNTING RAILS > Easily align rails and adjust in 1/4 inch increments > Toollessly mount busbars > Numbered U positions
VERTICAL 0U ACCESSORY CHANNEL > Toollessly mount cable management accessories or directly fasten cable bundles > Toollessly mount power distribution > Toollessly mount busbars
REMOVABLE SIDE PANELS AND FRONT/REAR DOORS > Half height side panels for easy and safe handling > Perforated front and rear doors > Lockable > Doors, sides, roof, and rails are bonded to frame
PRE-INSTALLED LEVELING FEET AND CASTORS
3000 lb static load capacity
NetShelter AV Ease of Use Designed for easy cable access for conduit & cable bundles and toolless installation & removal Cable access panels with a variety of conduit knockouts
Incorporates large open areas for cable entry/exit from enclosure Modular brush sections are used for air containment and aesthetics Utilizes toolless mounting Removeable cable access panels Conduit knockouts varying in size from 1/2 to 2.5 in
NetShelter AV Roof Fan Tray Features Promotes Proper Airflow •Helps to maintain proper rack temperatures within the enclosure by promoting top to bottom airflow movement.
Quiet Operation •Professionally engineered to quietly cool in studio or other applications where noise is a concern.
Enclosure System Compatible •Specifically designed to work with the NetShelter AV rack enclosure.
Fault Tolerant Fan System •In the event of a fan failure, the remaining fans will continue to operate
Easy to Install •Innovative design allows for fast, easy installation by almost anybody.
Rack Space Optimized •Mounts to the top of enclosure, leaving valuable space for other equipment.
NetShelter AV Enclosure Accessories 20U COPPER BUSBAR KIT – AR8395 > Toollessly mount in multiple locations throughout the enclosure > Provides installed equipment a grounding option from within the enclosure
TOP MOUNT CONDUIT ACCESS ADAPTER-AR7215 > Toollessly mounts directly to the top of AV enclosures > Features a variety of knock out hole sizes for conduit > Once installed the enclosure roof can be re-installed on top of the adapter securing the top of the enclosure
ADJUSTABLE SHELF 250LBS 18 – 25” DEEP BLACK – AR8125 > Occupies 1U of racks space conserving valuable rack space in the AV environment > Ventilated shelf allows ample ventilation for installed AV equipment > Optional provided shelf sides and back allow you to securely place items on the shelf
NetShelter SX with Shock Packaging Rack and Stack Made Easy for Equipment Integrators and Converged Deployments
1
Foam Padding
2
Removable Cardboard Wrap
1
4
3 2
3
> Protects exterior sides from handling damage
> Reusable > Convenient place for integrator logos > Conceals cabinet contents > Keeps dust and debris away from equipment
Multi-Layer Pallet > Absorbs impact and vibration during transit > Distributes cabinet load evenly across pallet
4
Ramp > Built in rails guide rack safely to floor > Stores within pallet footprint
NetShelter SX with Shock Packaging Cabinet paired with shock absorbing pallet, unloading ramp, and impact resistant shell
1
2
5
3 4
1
Additional mounting rail fasteners
2
Two-Piece Removable Cardboard Wrap
3
Cabinet Elevation Brackets
4
Heavy duty castors
5
Fixed rear castors
>Supports load even under high vibration >Securely holds rail position during transport
>Reusable >Convenient place for integrator logos >Conceals cabinet contents >Keeps dust and debris away from equipment
> Support of the weight load underneath & front/rear via bracket attachment > 4 brackets elevate casters during shipment to eliminate long period of weight load during shipment
>More durable, higher load ratings, and smoother rolling profile ensure proper performance at the delivery site under heavy weight conditions
>Helps to guide the rack straight down the ramp >Improves steering with fully loaded rack
Integrator Rack and Stack Made Easy The cabinet stays securely on the same pallet all the way to its final destination
Four easy steps to a hassle-free onsite deployment with shock packaging:
Remove outer wrap layers
Install and test IT equipment
Reapply protective packaging
Ship to customer site for installation
Designed to safely load, transport, unload and deploy a cabinet with up to 907 kg (2000 lbs) of IT equipment installed.
Rack Customization and Assemble-to-Order Capabilities – Assemble to Order (ATO) ● Provides the ability to assemble racks to the customers needs ● Standard configurations have x-options available ● Racks with no doors – X609 ● Racks with no side panels – X617 ● No doors/no sides – X617 ● More detailed configs include: ● Racks with split front doors ● Modified internal configuration ● No Roof
Cable Management Cable Management Accessories for NetShelter SX Enclosures
NetShelter SX: Cable Management Applications Vertical Cable Organizer AR8442 Mounts toollessly in rear of enclosure in optional rear channel (0U space) Occupies one bay of the 0U channel Supports up to 55 Cat6 cables each
Cable Containment Brackets AR7710 Mounts toollessly in rear of enclosure in optional rear channel (0U space) Occupies 2 bays of the 0U channel Supports up to 90 Cat6 cables each
Zero U channels can be ordered separately - AR7501 – 42U (qty 2) -AR7552 – 45U -AR7572 – 48U
Cable Management for NetShelter SX Offer high density cable management options for 600mm wide Enclosures • New AR3x0x 24in (600mm) wide enclosure vertical managers • New cable guide design to allow more cabling per U space • Dedicated 42, 45, and 48U versions to optimize u space coverage • Toolless plastic cable rings – 10 pack and 100 pack – simple to install / remove provides adaptability
Rear AR7721 -42U AR7722 – 45U AR7723 – 48U
AR7540 – Qty 10 AR7540100 – Qty 100
Rear
High Density Cable Management for NetShelter SX ● Vertical Cable Managers for 750mm Wide Enclosures
● Fits standard 750mm wide enclosures AR3x5x front or back ● New unique cable managers sizes for each height enclosure ● 42 – AR7580A ● 45 – AR7585 ● 48 – AR7588 ● Mount up to 4 per enclosure ● New 6” durable fingers provide 30% more space for cabling at each U-space ● Cable retainers provided standard ● Covers available as options for each enclosure height ● 42 – AR7581A ● 45 – AR7586 ● 48 – AR7589
● AR7707 Large Cable Rings
● Mounts to front equipment rails of the 750mm wide enclosures
Rear
NetShelter SX Networking Applications ● Vertical Cable Managers for NetShelter SX Networking Enclosures ● Pre-installed in the front of the enclosure for networking applications ● Cable guides (fingers) align at each u-space ● Optional accessory kit for mounting cable managers to the rear mounting rails ● AR7717A – 42U ● AR7727 – 45U ● AR7737 – 48U ● New 6” durable fingers provide 30% more space for cabling at each U-space
Front Cisco Catalyst 6500 Series – AR3140 Enclosure and AR7715 Side Airflow Duct kits
Overhead Cable Management System Overview Data and power cabling are required to interconnect IT equipment in single-multiple racks within the datacenter Cable management is critical to installation, airflow efficiency, and long-term maintenance of datacenters This solution saves space and installation cost by integrating overhead cable management directly with the top of the enclosure roof The solution includes cable troughs, ladders, and partitions: – – –
Designed for quick, tool-less installation with multiple configurations and flexibility using the same basic set of components Installation on top of the enclosure and a aesthetically pleasing option blending in with your datacenter No need for a raised floor or expensive suspended cable tray systems
● 1 – Power CableTroughs ● 2 – Pass-through Data Partitions ● 3 – Solid Data Partitions ● 4 – Cable Ladder Systems
Summary: The Schneider Electric Differentiators ● NetShelter SX enclosures offer the most standard, out-of-the-box features to ease installation and speed deployment. ● Single enclosure design is flexible to accommodate various networking and server applications.
● Seamless integration with APC InfraStruxure products such as Power Distribution, In Row Cooling and Uninterruptible Power Supplies ● Global manufacturing, inventory and distribution recognized as a world leader in data center infrastructure.
NetShelter® SX Networking Enclosure Cable Access Roof • Extra large cable access slots for high density cabling and brush strips for air containment • Two spring loaded pins allow for easy roof removal and installation with cables in place
Cable Management Mounting Rails • Easily align rails and adjust in 1/4 inch increments • Right vertical mounting rail opened for improved side airflow • Left vertical mounting rail contains addition cable channel • Rail position preset to accommodate Cisco switches and cable management
CFD Analysis on Cisco 6509 switch with side airflow duct kit 1. Duct kit directs cold air into intake and isolates hot air. 2. Hot, exhaust air is directed to the rear of the enclosure 3. Cable routing does not affect airflow since the air pulled in from the top and bottom ducts.
2
1 3
Side Airflow Duct Kit AR7715 – not included • Single design for compatibility with Cisco 6509, 6513, 9509, 9513 switches • Isolation of hot and cold aisle increasing equipment life Networking enclosure system compatible
AR3140 – Networking Enclosure 42U x 750mm W x 1070mm D
Modified wide NetShelter SX design for improved networking application support and a superior solution for side airflow Cisco 6500 and 9500 series switches
Introducing NetShelter® CX APC by Schneider Electric
Some important context Our world is undergoing great change. Increasing demand for energy, storage & computing. Shifting & rising energy prices. Continued political volatility. The planets finite resources.
Every watt Every inch of space Every minute Every cent counts.
Some important context The IT landscape is changing dramatically Virtualization shrinking the IT footprint Cloud Computing less IT on the premises Data Centers Server Rooms Wiring Closets high costs of space & energy
Making change work for you Our commitment:
Adapt to evolving markets Deliver tools to increase revenue & profit Offer a ‘full solution’ portfolio Change brings opportunity with it. We have listened & understood. Now we are reacting. Adapting. And delivering innovation.
Our new Innovation
The Netshelter CX. A soundproofed
‘Server Room in a Box’ Allowing for IT deployment wherever and whenever it is needed - saving space, cost and deployment time.
The Netshelter CX A soundproofed ‘Server Room in a Box’.
Available in 4 sizes.
Mini
18U
24U
38U
The Netshelter CX Truly ‘plug-and-play’.
Features of the CX 1. Soundproofed enclosure 2. Integrated ventilation fans
5 1
3. APC Power distribution included 4. Mobile, on heavy-duty castors 5. EIA spec 4 post 19-inch rack
6
8
6. Lockable front doors
7
7. Front & rear accessory rails, for cable management 8. Detachable side panels & rear fan-units for easy access.
4
The Netshelter CX Truly ‘plug-and-play’.
Features of the Mini 1. Soundproofed enclosure
6
2. Integrated ventilation fans 3. Power strip included
6
7
4. Mobile, on office castors 5. Adaptable to take a 19” Rack
2
6. Lockable front & rear doors 7. Two Cable Ingress points
3
4
1
The Netshelter CX
The positioning is simple.
Main IT Hub
Remote IT Hub
For SMEs, medical, AV and the smaller self-contained operations
For multi-site operations such as banking, retail, national & multinationals
The Netshelter CX
The missing piece in the jigsaw.
Small Office
Remote Data Closet Small Server >5kw Room 5-20kw Office
Small-Medium Large Data Data Centre 50- Centre >200kw 200kw
Now we offer the full infrastructure solution From small or remote office to Data Center - we’ve got the lot.
The Netshelter CX
Identifying the opportunities. • Is the cost to build a server room prohibitive? • Are you forced to deploy hardware into insufficient space? • Have you ‘maxed-out’ your Server Room? • Are you standardizing IT deployment across multiple offices? • Where are you going to put new or remaining hardware following Virtualization? • Are you deploying IT equipment in a non-dedicated space? • Do you face challenges getting network closets and/or server rooms built? • Do you have a need for IT hardware in the open office space? • Are you experiencing change in terms of growth or down-sizing? • Does you have Health & Safety problems with noisy servers?
Virtualization project? Building Restrictions?
Green targets? Multi-site roll-out?
Cost reduction project? Leased premises?
Business Start-ups? Cloud Computing?
The Netshelter CX
Proven target sectors. • Corporate (Branch Office) • Retail Branches • SME/SMB • Finance (e.g. Bank branches)
• Professional AV & Media Studios • Schools • Home Offices • Local Government Offices • Health – Medical clinics or hospitals
• Start-ups • Interior Design Sector • Corporate (Wiring Closet) • Gaming & home entertainment • Temporary premises
The Netshelter CX Main Hub Example.
An office scenario.Estimated £33,142 total year 1 savings. In this example:
Softcat is an IT Reseller with offices in London, Manchester and Marlow, UK Application: Main IT Hub, housing servers, network switches & storage Savings:
£11k upfront building costs £15k space saving (annual rent) £5k annual energy reduction 27 tons of carbon saved
Model: AR4038i Physical capacity: 38 rack spaces Integrated APC PDU: 12 IEC outlets Max thermal load: 3.6 kW Noise reduction: 18.5 dB Power consumption: 101 watts Cable access: Top & bottom rear For user guides, brochures, testimonials and other product information visit www.apc.com
The Netshelter CX
Remote Hub Example. For a National Retailer. In this example:
Screwfix has 96 Trade Branches in the UK And now has a Netshelter CX in each one.
Model: AR4018i
That’s 96 individual CX units, each one with an opportunity to attach a UPS, a Network Management Card, accessories and other third party equipment such as servers, switches & patch panels. Not to mention warranties, maintenance and service.
Physical capacity: 18 rack spaces Integrated APC PDU: 14 IEC outlets Max thermal load: 1.2 kW Noise reduction: 18.5 dB Power consumption: 101 watts Cable access: Bottom rear For user guides, brochures, testimonials and other product information visit www.apc.com
The Netshelter CX
Attach, attach, attach. Use the CX to create the full office IT solution.
Smart UPS Switches Netbotz Devices Servers Switched PDU Patch Panel
Network Management Card
Routers
Netshelter Accessories
Other 3rd party kit
AV Power Filter
The Netshelter CX Summarized.
A soundproofed ‘Server Room in a Box’ Allowing for IT deployment wherever and whenever it is needed, saving space, cost and deployment time
End-User
Partner
Save space Save CapEx Save Opex Save time Stay flexible
Offer full solution Attach more product to a sale Attach services to the solution Attract new customers From new markets And keep them longer
The Netshelter CX
Available Resources
APC.com Brochures Videos Technical Guides Vertical Flyers Remote Management Guide
APC Sales Portal Netshelter CX Overview ‘How to Sell’ Presentation & Video Channel Partner Sales Guide Quick Reference Sales Sheet Customer Testimonials
http://www.youtube.com/watch?v=28U3idHxkjU
Tableros y accesorios Industriales para aplicaciones TI Disponibles desde abril 2015
Características principales •Puerta frontal vidrio templado, IK08 • Puerta posterior IK10, apertura 120° • IP55, Según IEC 60529 • Certificaciones: BV, DNV, UL*, CUL. NEMA 1, 3R, 12, 12K • Carga máxima: 1000 Kg •Referencia global no incluye bastidor, por separado solicitar móvil o fijo •Pintura epoxi-poliéster • Color RAL7035
Configuración estándar para Aplicaciones TI
ZP0SFCE200X80X80T DIMENSIONES Alto x Ancho x Prof. (mm)
: 2000x800x800
Componentes
Referencia
Montantes verticales de 2000mm (4 unid)
NSYSFV20
1
NSYSFC88
1
Puerta ciega posterior 2000x800 mm
NSYSFD208
1
Puerta transparente 2000x800 mm Tapa inferior entrada de cables Paneles Laterales 2000x800 mm
NSYSFD208T NSYEC88 NSY2SP208
1 1 1
Zócalos frontal y posterior 800x100 Zócalos laterales 800x100 mm
NSYSPF8100 NSYSPS8100
1 1
NSYSH180
1
Techo y base inferior 800x800 mm
Bisagra de 180°
ZP0SFCE200X80X80T
ZP0SFCE200X80X100T DIMENSIONES Alto x Ancho x Prof. (mm) : 2000x800x1000
ZP0SFCE200X80X100 T
Componentes
Referencia
ZP0SFCE200X80X100T
Montantes verticales de 2000mm (4 unid) Techo y base inferior 800x1000 mm
NSYSFV20
1
NSYSFC108
1
Puerta ciega posterior 2000x800 mm
NSYSFD208
1
Puerta transparente 2000x800 mm
NSYSFD208T
1
Paneles Laterales 2000x1000 mm
NSYBP2010
2
Tapa inferior entrada de cables
NSYEC108
1
NSYSH180
1
Zócalos frontal y posterior 800x100
Bisagra de 180°
NSYSPF8100
1
Zócalos laterales 1000x100 mm
NSYSPS10100
1
Accesorios para Tableros TI Descripción y características
Referencia
ACCESORIOS DE MONTAJE
Bastidor pivotante para tableros de 2000x 800mm (alt. x ancho) 19" Bisagra para bastidor pivotante 180° NSYRCK42
Bastidor fijo 19" Refuerzo de bastidor para tableros de 800 mm de ancho
Escuadras de soporte para bastidor tableros de 800 mm de ancho Traviesas Rapidas de 65mm de ancho 1000mm de long ZÓCALOS
Kit de tuercas tornillos y arandelas para rack 19"
Descripción y características Zócalo frontal y posterior con escobilla 800x100 mm (vienen 2 zócalos)
NSYRSW40 NSYSPB8100
NSYRSW4 0 NSYRSWH1 80 NSYRCK42 NSYRCK19KI T NSYRCKS1 0 NSYSQCR651 00 NSYGFR95M 65
Referencia NSYSPB810 0
Aplicaciones en Tableros TI
Data Centers
Server Rooms
Gabinetes de Telecomunicaciones a la Intemperie
New Schneider Electric Micro Data Center Solutions Febrero 2017
Growth is driven by the connected users and the Internet of Things
2 Billion Internet users
21 Billion network devices 1.3 Million video views per min
665TB
Data per hospital per year
40TB data transmitted / flight hr 2
Datacenter and Cloud/IoT Landscape <10ms latency
Edge or Local Datacenter
Large Datacenter Enterprise/Cloud/Colo
>100ms latency
Heavy processing and data storage
Devices
Devices
Datacenter and Cloud/IoT Landscape
<10ms latency
The future architecture will likely have at least 3 variations
Devices 1)Could be a gateway or embedded device
2) Could be 1-8 racks or micro data center
Large Datacenter Enterprise/Cloud/Colo ldd bdeataa regional Heavy proce3s)siC ngou an storage data center’
Devices
4
Customer Trends
Enterprise: finance, retail, outsourced IT Industrial: oil & gas, mining, manufacturing
Government and Military Healthcare and Education
Customer Trends
Enterprise: finance, retail, outsourced IT • Retail stores connecting to customer devices for mapping apps, buying habits, targeted sales, financial transactions, etc. • Banking branches becoming more automated and integrated into retail sites. Dedicated space for IT infrastructure is not available. • SMB enterprise customers with outsourced IT still require local storage, and networking for critical applications requiring low-latency. Often an upgrade of “left over” infrastructure is needed.
Customer Trends
Industrial: oil & gas, mining, manufacturing
• Exploration is sites are producing massive amounts of data through sensors and imaging that need to be processed on site for real-time analysis • Production and manufacturing facilities are becoming highly automated. IT equipment has short life span if not protected from harmful airborne particles and heat. • Assembly plants use autonomous robots, video sensors, automated lines that all require local processing on the factory floor
Customer Trends
Government and Military
• Regional governments and interdepartmental offices often require data to be kept on site/campus. Physical security and disaster recovery are critical to operations • Military forward operations are managing data from drones, field cameras, and smart weaponry. Mobile command centers need to be operational in many different types of harsh environments.
Customer Trends Healthcare and Education
• Demand on Hospital data centers is driving expansion. • Imaging, video and patient data need to be processed and distributed to different departments on campus or remote offices. • Local processing is needed at nurses stations, lab facilities, and operating rooms. • University research laboratories require powerful processing in areas typically not designed for the necessary power and cooling. • In addition, they often have small windows of time to upgrade infrastructure.
Schneider Electric´s Micro Data Center definition
A micro data center is a self contained, secure computing environment that includes all the storage, processing and networking required to run the customer’s applications. It ships in single enclosure and include all necessary power, cooling, security, and associated management tools (DCIM). Micro data centers are assembled and tested in a factory environment.
Micro Data Center Solutions 12
SmartBunker™ SX, CX, &FX
Schneider Electric’s new micro data center portfolio integrates SmartBunker SmartShelter and NetShelter Solutions SmartBunker SX – Value priced solutions for traditional IT environment SmartBunker CX – Sound-proof with decorative exterior for office environment
Smart Shelter™
SmartBunker FX – Secure, insulated, dust-proof, and actively cooled for industrial environments
SmartShelter Modules and Containers – Integrated, weatherproof, fire-rated, deploy anywhere solution
All manufactured, assembled & tested in a Schneider Electric facility
New SmartBunker Solutions
SmartBunker SX Traditional for IT rooms • 24 and 42U > 3 or 5kVA UPS > Netbotz environmental monitoring > 1 Switched Rack PDUs > Passive cooling
SmartBunker CX Optimized for office environments • 24U and 38U > > > > >
3 or 5kVA UPS Netbotz environmental monitoring 1 Switched Rack PDUs Sound proofing Fan-assisted ventilation
SmartBunker FX Industrial Environments • 23U and 42U > > > > > > >
5 and 8kVA UPS Electrical Input panel Netbotz environmental monitoring 1 Switched Rack PDUs Active DX cooling solutions Thermal insulation Sealed enclosure 13
Orderable QSKU
Description
U Height
IT Capacity
Cooling Type
UPS
SmartBunker SX
PFMSB30024
QGEN3626-00
SmartBunkerSX 24U 3kVA UPS - EMEA
24U
2.7 KW
None
3 KVA Smart UPS
PFMSB30042
QGEN4121-00
SmartBunker SX 42U 5KVA UPS - EMEA
42U
4.5 KW
None
5 KVA Smart UPS SRT
PFMSB40024
QGEN4525-00
SmartBunker CX 24U 3KVA UPS - EMEA
24U
2.7 KW
Fans - Forced Ventilation
3 KVA Smart UPS
PFMSB40038
QGEN4998-00
SmartBunker CX 38U 5KVA UPS - EMEA
38U
4.2 KW
Fans - Forced Ventilation
5 KVA Smart UPS SRT
PFMSB50023
QGEN98611-00
SmartBunker FX 23U 5KVA UPS Air Cooled EMEA
23U
3.5 KW
DX Top Cooling
5 KVA Smart UPS SRT
PFMSB51042
QGEN1773-00
SmartBunker FX 42U 5KVA UPS Air Cooled In-Row SC - EMEA
42U
4.5 KW
InRow SC
5 KVA Smart UPS SRT
PFMSB50042
QGEN3129-00
SmartBunker FX 42U 8KVA UPS Air Cooled/DX In-RowRD - EMEA
42U
8.0 KW
InRow RD
8 KVA Smart UPS SRT
SmartBunker FX
Reference Number
SmartBunker CX
Smart Bunker
SmartBunker SX - 2.7 KW: Características y Componentes Rack Access Gabinete Netshelter SX de 24 U, 600 mm de ancho x 1070 mm de prof – Shock Packaging
> Control de Acceso por proximidad NetBotz
Rack PDU, Switched, 1U, 16A, 208/230V, (8)C13
StruxureWare Data Center Expert software for remote management and realtime monitoring
Administración deCableado y Flujo de Aire y Acesorios: • • • • APC Smart-UPS X 3000VA Rack/Tower LCD 200-240V with Network Card
Blanking Panels Brish Strip Panel Ordenador Vertical de cables Ordenador Horizontal de cables
SmartBunker SX - 4.5 KW: Cracterísticas y Componentes Gabinete Netshelter SX de 42 U, 600 mm de ancho x 1070 mm de prof – Shock Packaging
Sistema NetBotz 450 de Seguridad y Monitoreo Ambiental > Cámara Fija > Sensor de Temp y Humedad > Detector de Humo > Control de Acceso
Rack PDU Switched, ZeroU, 16 A/230 V, (7) C13 & (1) C19 StruxureWare Data Center Expert software for remote management and realtime monitoring
Power Cord, Locking C19 to C20, 3.0 m
Administración deCableado y Flujo de Aire y Acesorios:
APC Smart-UPSVSRT 5000va RM 230V
• • • •
Blanking Panels Brish Strip Panel Ordenador Vertical de cables Ordenador Horizontal de cables
SmartBunker CX – 2.7 KW Características y Componentes Rack Access Control de Acceso por proximidad NetBotz
Superior sound proofing on all interior surfaces. Clean, decorative exterior to match office decor
Rack PDU,Basic, 1U, 10A/230V, (15) C13, incluido en el CX StruxureWare Data Center Expert software for remote management and realtime monitoring
Rack PDU,Switched, 1U, 16ª/230 V , (8) C13
IT equipment can be installed in an office space without the cost of building a dedicated IT room
Administración deCableado y Flujo de Aire y Acesorios:
APC Smart-UPS X 3000VA Rack/Tower LCD 200-240V with Network Card
• • • • • • •
Blanking Panels Brish Strip Panel Ordenador Vertical de cables Ordenador Horizontal de cables Handle Adaptor Kit Filtros de polvo Fan Booster Kit
SmartBunker CX – 4.2 KW Características y Componentes
Superior sound proofing on all interior surfaces. Clean, decorative exterior to match office decor
StruxureWare Data Center Expert software for remote management and realtime monitoring
Sistema NetBotz 450 de Seguridad y Monitoreo Ambiental > Cámara Fija > Sensor de Temp y Humedad > Detector de Humo > Control de Acceso
Rack PDU Switched, ZeroU, 16 A/230 V, (7) C13 & (1) C19
Power Cord, Locking C19 to C20, 3.0 m IT equipment can be installed in
APC Smart-UPSVSRT 5000va RM 230V
Administración deCableado y Flujo de Aire y Acesorios: • Blanking Panels • Brish Strip Panel • Ordenador Vertical de cables • Ordenador Horizontal de cables • Handle Adaptor Kit • Filtros de polvo • Fan Booster Kit
an office space without the cost of building a dedicated IT room
SmartBunker FX – 3.5 KW Propiedades y Componentes Sistema NetBotz 450 de Seguridad y Monitoreo Ambiental > Cámara Fija > Sensor de Temp y Humedad > Detector de Humo > Control de Acceso
Top Mount cooling unit 4 KW
StruxureWare Data Center Expert software for remote management and realtime monitoring
Rack PDU,Basic, 1U, 10A/230V, (15) C13, incluido en el CX
>Superior physical protection with heavy gauge steel construction >Thermally Insulated walls keep cold air in and hot air out
Rack PDU,Switched, 1U, 16ª/230 V , (8) C13 Multi-point locking door and Netbotz Rack Access proximity card locking system
Power Cord, Locking C19 to C20, 3.0 m >Front and rear access with 180° Power Cord, Locking C13 doors to C14, 3.0 m
Administración deCableado y Flujo de Aire y Acesorios:
APC Smart-UPSVSRT 5000va RM 230V
>Wall construction provides superior sound attenuation
• • • •
Blanking Panels Brish Strip Panel Ordenador Vertical de cables Ordenador Horizontal de cables
SmartBunker FX – 4.5 KW Propiedades y Componentes Sistema NetBotz 450 de Seguridad y Monitoreo Ambiental > Cámara Fija > Sensor de Temp y Humedad > Detector de Humo > Control de Acceso
StruxureWare Data Center Expert software for remote management and realtime monitoring
Switched and metered rack PDU with remote monitoring
>Superior physical protection with heavy gauge steel construction >Thermally Insulated walls keep cold air in and hot air out >Wall construction provides superior sound attenuation
Multi-point locking door and Netbotz Rack Access proximity card locking system
Power Cord, Locking C19 to C20, 3.0 m
>Front and rear access with 180° doors
InRow self-contained, active DX cooling with monitoring, controls, and display Fire-rated and sealed cable entries Confidential Property of Schneider Electric
APC Smart-UPSVSRT 5000va RM 230V
SmartBunker FX – 8 KW Propiedades y Componentes Sistema NetBotz 450 de Seguridad y Monitoreo Ambiental > Cámara Fija > Sensor de Temp y Humedad > Detector de Humo > Control de Acceso
StruxureWare Data Center Expert software for remote management and realtime monitoring
Switched and metered rack PDU with remote monitoring
>Superior physical protection with heavy gauge steel construction >Thermally Insulated walls keep cold air in and hot air out >Wall construction provides superior sound attenuation
Power Cord, Locking C19 to C20, 3.0 m Power Cord, Locking C13 >Front and rear access with 180° doors to C14, 3.0 m
Multi-point locking door and Netbotz Rack Access proximity card locking system
InRow self-contained, active DX cooling with monitoring, controls, and display Fire-rated and sealed cable entries Confidential Property of Schneider Electric
APC Smart-UPS SRT 8000VA RM 230V
What is the value? > What is the value of the space in a hospital or university?
…It is not price!
Avg hospital patient room in US generates $950,000 per year
> What is the cost to build a new building in a remote mining site?
These solutions solve specific problems that address space, speed, and reliability
Factor in transportation of all the materials and labor over the entire project
> What is the cost and time to build a small IT room in a factory? Must include retrofitting the building for cooling and Power
Customers are trying to achieve these objectives Increase: • • •
Consistency across locations Reliability through factory production versus ‘stick built’ Predictability and quality
Reduce: • • •
Unique engineered solutions Distractions from core business Time: deployment, troubleshooting
Minimize: • • •
Complexity of on-site work, testing, or commissioning Configuration and programming Cost overruns from construction
Case Study: SmartBunker CX Sporting & Outdoor Retailer, USA Customer Challenge • Current approach was a mix and match of different size, type, and quality of racking and equipment in the back of their stores • The challenge was bring 124 stores throughout the US to a common standard Solution • Fully configured single-rack solutions • Included UPS, PDU, servers, storage and networking • Pre-configured, crated and shipped as a plug-andplay solution to customer sites • Only 1 IT technician needed on-site to start-up and operate
BEFORE
Case Study: SmartBunker FX Ministry of Health, South America 23
Customer Challenge • Need for simplified, secure and stand-alone IT Infrastructure • Internal auto-provisioning and billing platform; cost assignment to each department • SaaS deployment; centralized app management • OpEx reduction (energy reduction, management) Our Solution • 9 single racks (1 per hospital) with air conditioning, long runtime power protection and environmental monitoring • Simplified, secure, cost-effective
Case Study – SmartShelter Mackenzie Health - Toronto Customer Challenge: • Growing hospital with a need for greater data center capacity with little available space • Data center is support – not producing revenue. New building would cost too much • Need completed in 6 months
Solution: • • • • •
All-in-one SmartShelter Module 100kW PX UPS 12 racks, modular power, In-Row Cooling, Netbotz & DCIM software. Chiller supplied by Contractor
Influencers: SEPartner had relationship with hospital and Confidential Property of Schneider Electric engineer. Partner managed SEs interaction with engineer. Local contractors install.