Preview only show first 10 pages with watermark. For full document please download

Sonarhub Dimensions Installation Guide For Technical Specifications, Certificates And

   EMBED


Share

Transcript

Dimensions 204 mm (8.03") 57 mm (2.24") 169 mm (6.63") For technical specifications, certificates and declarations, refer to the product web site on: SonarHub Installation Guide 12V/24V 3A POWER NET-1 NET-2 NET-3 207 mm (8.15") 91 mm (3.58") TRANSDUCER1 lowrance.com 180 mm (7.09") simrad-yachting.com TRANSDUCER2 *988-10539-001* 183 mm (7.20") Parts included NET-2 NET-3 7 10 TRANSDUCER1 1 1 1 1 2 SonarHub installation screws 4 4 4 4 4 3 Ethernet cable, 4 m (15 ft) 1 1 1 1 1 4 Power cable, 2 m (6.6 ft) 1 1 1 1 1 5 Fuse and Fuse holder 1 1 1 1 1 6 LSS StructureScan HD XDCR 7 TM150 CHIRP XDCR 8 SPOTLIGHT Heading sensor 1 9 Trolling Motor clamp 1 NET-1 1 1 TRANSDUCER1 TRANSDUCER2 TRANSDUCER1 TRANSDUCER2 12V/24V 3A 1 NET-2 1 TRANSDUCER2 10 SPOTLIGHT XDCR 1 NET-3 1 NET-3 SonarHub module TRANSDUCER1 1 NET-2 SonarHub w/ SPOTLIGHT XDCR NET-1 SonarHub w/ LSS TM150 and LSS HD XDCRs 12V/24V 3A SonarHub w/ TM150 XDCR POWER SonarHub w/ LSS HD XDCR NET-3 SonarHub only NET-2 000-11304-001 NET-1 000-11301-001 12V/24V 3A 000-11141-001 000-11300-001 POWER ID DESCRIPTION 000-11142-001 TRANSDUCER2 POWER 5 NET-1 3 9 8 6 12V/24V 3A 4 2 POWER 1 Mounting Power Wiring examples MULTI-FUNCTION DISPLAYS Power controlled by External Switch Power controlled by Multi-Function Display 4G RADAR WIFI-1 To Multi-Function Display 12 / 24 V DC Views on the MFD: + _ NET-3 Power Control bus Blue (n/c) SONARHUB 1 CHIRP 12 / 24 V DC NET-2 +_ Blue (n/c) Yellow NET-1 Switch Blue (n/c) Red 12V/24V 3A Red Yellow Black POWER Black Black Red Yellow 12/24 V DC or StructureScan plus single frequency 83 kHz TRANSDUCER1 TRANSDUCER2 1 12V/24V 3A POWER NET-1 NET-2 12V/24V 3A NET-3 POWER NET-1 NET-2 NET-3 2 CHIRP 2 and StructureScan TRANSDUCER1 TRANSDUCER2 TRANSDUCER1 TM150 TRANSDUCER2 LSS HD Connectors and LEDs 4G RADAR ID 2 1 No connection ON/FLASHING - Green Connected and ok OFF No power ON - Red System starting ON - Green System operating FLASHING Red/Green Software error - restart unit OFF Sounder not operating 12V/24V 3A Operational system with bottom signal detected OFF Sounder not operating FLASHING (every second) - Green Searching for bottom signal ON Operational system with bottom signal detected NET-3 4 Structure Scan HD transducer, Spotlight transducer Searching for bottom signal SONARHUB NET-2 4 CHIRP / Broadband FLASHING (every second) - Green transducer ON SPOTLIGHT HEADING SENSOR NET-1 TRANSDUCER2 Power 12V/24V 3A NET-1 NET-2 NET-3 3 3 OFF POWER 2 TRANSDUCER1 Ethernet LEDs POWER 1 CONNECTORS HDS NON-TOUCH MULTI-FUNCTION DISPLAYS 12/24 V DC NMEA 2000 NETWORK T T 12 V DC TRANSDUCER1 TRANSDUCER2 SPOTLIGHT TRANSDUCER