Preview only show first 10 pages with watermark. For full document please download

Sonexion 1.5 1600/900 Release Notes

   EMBED


Share

Transcript

Sonexion 1.5 1600/900 Release Notes Contents Contents 1 About Sonexion 1.5 1600/900 Release Notes........................................................................................................3 2 Software Versions and Requirements....................................................................................................................4 3 What’s New for Sonexion 1.5.0 1600/900...............................................................................................................6 4 Known Issues for Sonexion 1.5.0...........................................................................................................................8 5 CSCLI Changes in Release 1.5 1600/900..............................................................................................................9 6 Firmware...............................................................................................................................................................11 7 Supported 1600/900 Hardware Components ......................................................................................................17 2 About Sonexion 1.5 1600/900 Release Notes 1 About Sonexion 1.5 1600/900 Release Notes This publication includes information about the environment, software requirements, supported upgrade paths, bug fixes, notices, known issues, list of code versions, and component firmware versions for this release of the Sonexion 1600 or 900 system. Table 1. Record of Revision: publication S-2533-15 Publication number Date Note S-2533-15a September 2014 Sonexion 2000 version S-2533-15b June 2015 Sonexion 1300/1600 version Sonexion 1600 System Sonexion 900 System 3 Software Versions and Requirements 2 Software Versions and Requirements In order to upgrade to Sonexion 1.5.0, the system must already be running release 1.4.0. CSSM Version Version Current Version CSSM CSSM 1.5.0 (SU07) Build v. r23586, 2015-05-06 USM 3.20 Sonexion 2000 X Sonexion 1600 X Sonexion 900 X Lustre Server (x86_64 Architecture) Version Current Version Operating System Scientific Linux 6.2 (Carbon) Kernel 2.6.32-220.7.1.el6.lustre.4230 File System 2.1.0.x5-133_2.6.32_220.7.1.el6.lustre.4230.x86_64_gce10faa Summary List of Requirements The following table summarizes the public Lustre client support matrix. Lustre clients are closely tied to the distribution, Linux Kernel version, and are dependent on OFED drivers. Please consult with your Cray representative to confirm details of your specific client configuration. Client Version Distributions 1.8.8-x1 Oracle Enterprise Linux 6.3 Oracle Enterprise Linux 6.4 1.8.9-wc Scientific Linux 6.2 Scientific Linux 6.4 SUSE Linux Enterprise Server 11SP2 2.1.5-wc Scientific Linux 6.2 Scientific Linux 6.4 SUSE Linux Enterprise Server 11SP1 2.4.1-wc N/A Scientific Linux 6.4 SUSE Linux Enterprise Server 11SP2 4 Software Versions and Requirements Management Node Network Infrastructure Requirements* DHCP Server Provides the management nodes’ IP addresses for browser connections. NTP Server Synchronizes clocks across the cluster’s nodes. DNS Server Resolves LDAP and NTP host names on the management nodes. * Manual workarounds may be available for environments without these servers. Please contact your support representative. Port 3306 must be open between the browser and the CSSM server in order to view Lustre performance information. Supported Browsers Sonexion supports the latest versions of Chrome, Firefox, and Safari browsers under Windows, Linux, and Mac OS operating systems. Please make sure the latest Java package(s) are installed for full management GUI functionality. Supported Upgrade Paths Release 1.5 supports upgrading from release 1.4.0 to release 1.5.0 for the following product types: ● Sonexion 900 MDRAID ● Sonexion 1600 MDRAID ● Sonexion 1600 GridRAID (formerly PDRAID) The RAID type cannot be changed as part of the upgrade (i.e., MDRAID will stay MDRAID and GridRAID will stay GridRAID). 5 What’s New for Sonexion 1.5.0 1600/900 3 What’s New for Sonexion 1.5.0 1600/900 The following new features and improvements are part of Sonexion 1.5.0: Introduction of new SSU hardware ● Ivy Bridge-EP (Socket R) Xeon E5-2648L v2 CPU 10 Cores - 1.9GHz, 20 MByte cache ● 8.5GB/sec performance ● Increased hardware utilization of SAS bandwidth CNG (CIFS/NFS Gateway) Sonexion 1.5.0 systems can support optional dedicated hardware server nodes with CIFS2 Export and NFS Export capabilities. CNG support enables Lustre file system access to be exported to CIFS/SMB2 and NFS clients. The CNG feature allows the Lustre filesystem to be shared using enterprise clients (Windows, Mac and Linux), and to use enterprise NAS CIFS2 and NFS by providing parallel multi-client access through multiple CNG nodes. The Clustered Trivial Database (CTDB) file-sharing technology, which is part of Samba, provides shared access to Lustre files across multiple CNG nodes. The CNG feature provides the following: ● Full support for clusters ● Chassis configuration with either two or four CNG server nodes ● Client access using CIFS/SMB2 or NFS protocol ● Full installation support ● Individual node operation as part of Samba CTDB cluster ● Individual node boot from the MGMT node running without dedicated local disk storage ● HA support – CNG server nodes manage file share locking between them ● ○ Multi-client access to the Lustre file system is supported and managed by the CTDB software ○ Clients may need to reconnect after failover CIFS authentication is automatically configured to be the same as for Lustre clients ○ Lustre users can be configured via AD, LDAP or NIS ○ Individual shares may instead be configured for passwordless guest access ● NFS clients automatically obtain the same user authorization as Lustre clients. Full installation support. ● Full support bundle and log support 6 What’s New for Sonexion 1.5.0 1600/900 ● Full support for health monitoring ● Full CSCLI support of the FRU inventory ● Manual FRU replacement of the chassis hosting CNG nodes ● Full support for changing ECN IP addresses of CNG ● Fully-featured share configuration including security ● Automatic configuration for supported LCN and ECN interfaces ● LCN: Full support for 40GbE and QDR/FDR IB ● ECN: Full support for 10GbE and 40GbE Other Changes ● Mellanox HBA firmware update for the MMU ● Support for Non-NSS Lustre upcall ● The Lustre Users functionality page is moved from the CSSM - Pre-Shipment Installation (also known as Customer Wizard) to the Configure tab in CSSM. ● Support for changing Lustre Users settings in Daily Mode from the GUI and CSCLI. The Configure tab in daily mode has NIS, LDAP (including multiple servers), and separate, simplified settings for AD. It also includes the option to define users directly on the Sonexion system by uploading /etc/passwd and /etc/ group files. All these settings can be edited or changed as often as desired. ● Support for local user/group definitions for Lustre users ● Support for multiple Lustre upcall methods simultaneously, for example, NIS, LDAP, etc. ● Support for changing Lustre Users settings in Daily Mode from the GUI and CSCLI ● Support LDAP over SSL for Lustre users ● Support for multiple LDAP servers ● Dual Management Network (DMN) support: ● ● ● ○ DMN is scalable ○ Provides redundancy at both the OS layer and the BMC layer ○ Easily upgraded or repaired New Lustre features: ○ Requires minimal support to maintain ○ New group upcall utility supporting several authentication methods (files, LDAP(s), NIS, NIS+) simultaneously. New Sonexion Switches: ○ Mellanox SX1024 ○ Intel TrueScale 12300 RAS: The Initial RAS release provides support for Disk Drive failures in all Cray developed storage enclosures, including all SSDs and HDDs. Note that the quad server of the MMU is not yet supported, but the MMU storage is supported. 7 Known Issues for Sonexion 1.5.0 4 Known Issues for Sonexion 1.5.0 Known issues for this release are listed below, with workarounds. Description Workaround The Service Action list is text rather than graphical icons and clicking on a service action does not display the service procedure in the main panel (view is empty). If the Service Action list is text rather than graphical icons and clicking on a service action does not display the service procedure in the main panel - please clear the browser cache for all time and refresh page. The Dashboard’s File System Throughput Chart view If the File System Throughput Chart is unavailable may disappear when Chrome is updated to the latest (that is, the view is empty), clear the browser cache for version. all time and refresh page. RAS action items may not automatically clean up after being archived. Reloading the page or clicking on another actionable item will update the displayed Action List and cleanup archived items. Build number and date tooltip blocked by LMT (Lustre Monitoring Tool) screen No workaround at this time 8 CSCLI Changes in Release 1.5 1600/900 5 CSCLI Changes in Release 1.5 1600/900 The following commands were added to this release: CSCLI Changes Addition/ Change CSCLI Command Description Component 1. Added ibstat_check Disables/Enables HA's probing of the high speed network HA stack 2. Added manage_guest Manages the guest account, a built-in account for read-only administrative use. User Management 3. Added show_node_versi ons Changes the image for a diskless node System upgrades 4. Added service_console Enables or disables the service console or displays the state of the service console Serviceability 5. Added lustre_users Lustre users command in Daily Mode. Many commands have changed and several commands have been added. These commands can now be performed from the Daily Mode. Advanced User Authentication Displays pdsh-style node names and the time window in minutes Support bundle settings support_bundle 6. Added support_bund collect le subcommand support_bundle show Displays triggers that initiate automatic bundle collection, a list of support bundles collected and the purge limit support_bundle export Displays the bundle ID support_bundle set Displays purge limit for the support bundle and triggers that initiate automatic bundle collection 7. Changed/ Updated Advanced Users Commands (Lustre Users Commands) 8. Changed ‘Customer Installation’ is referred to as ‘site configuration’ 9. Moved Lustre users setup from ‘Site Configuration’ (previously called ‘Customer Installation’) 9 CSCLI Changes in Release 1.5 1600/900 Addition/ Change CSCLI Command Description Component 1 Feature added in The rebuild_rate command displays the numerical values when the rebuild is in 0. rebuild_rate progress command 1 Updated 1. service_console 1 Added 2. cscli rack Extends the functionality of cscli get_rack_position and set_rack_position Rack 1 Added 3. UD Commands Unresponsive Drives Commands Disk Drive dm DM Service Configuration Management dwd DWD- Daemon Configuration Management Added or Changed CNG - CSCLI Commands N Addition/ o. Change CSCLI Command Description Component 1. Added cng Management of the CIFS/NFS Gateway (CNG) CIFS/NFS 2. Changed ‘Exporter nodes’ are referred to as ‘CNG nodes’ in the content of the document. The cscli export command is deprecated. Please use cscli cng instead for all --help outputs of cscli export, including all its subcommands. If the cscli export command is used the following message will be displayed: “This command is deprecated. Please use 'cscli cng' instead.” 3. Changed The cscli cng network command is deprecated. Please use cscli the cng clientgroup command instead.The cscli cng share cifs network command is deprecated. Please use the cscli cng share cifs clientgroup command instead. The cscli cng share nfs network command is deprecated. Please use the cscli cng share nfs clientgroup command instead. 10 Firmware 6 Firmware SSU System Firmware Versions for Sonexion 1.5.0 The following table provides a version list of the firmware components for the SSU 5U84 storage system released under USM 3.20 for the SSU enclosure. SSU Component Sub-Component Version Number Sonexion 900/1600 Application Controller Bootloader 05.03 Firmware 3.5.0.25 (0x3519) VPD Structure 0x06 VPD CRC 0xEE3504B4 Config CRC 0xD1B030A4 GEM CPLD 0x17 BIOS 0.46.0001 BMC Boot 2.0.0001 BMC Root 2.0.000A Main CPLD 0.17.0004 Intel Management Engine 1 Mellanox IB/Ethernet HCA Firmware 2.30.8000 PLX EEPROM VF22-LF-CRC: 0x98229A3E CPLD 0x05 VPD Version 0x0F VPD CRC 0x0E74E375 Primary 2.1E Secondary 2.28 EEPROM 2.00 VPD Version 0x03 XYR VPD CRC 0x486003DF Firmware 2.3.6 (Config 0960837-04) Midplane 2814W PCM Cooling Fan Module 11 Firmware SSU Component Sub-Component Version Number Sideplane Bootloader 06.10 Firmware 3.5.0.25 (0x3519) RHS Sideplane CPLD 0x10 (Sled 1 Element 2, Sled 2 Element 2) (Sled 1 Element 3, Sled 2 Element 3) RHS 24 Port Expander VPD Structure 0x06 (Sled 1 Element 2, Sled 2 Element 2) RHS 24 Port Expander VPD CRC 0x152E4AD9 (Sled 1 Element 2, Sled 2 Element 2) RHS 24 Port Sideplane Config CRC 0xFA337B92 (Sled 1 Element 2, Sled 2 Element 2) RHS 36 Port Expander VPD Structure 0x06 (Sled 1 Element 3, Sled 2 Element 3) RHS 36 Port Expander VPD CRC 0x38B21CF7 (Sled 1 Element 3, Sled 2 Element 3) RHS 36 Port Sideplane Config CRC 0x6591A901 (Sled 1 Element 3, Sled 2 Element 3) LHS Sideplane CPLD 0x10 (Sled 1 Element 0, Sled 2 Element 0) (Sled 1 Element 1, Sled 2 Element 1) LHS 24 Port Expander VPD Structure 0x06 (Sled 1 Element 0, Sled 2 Element 0) LHS 24 Port Expander VPD CRC 0xF027D510 (Sled 1 Element 0, Sled 2 Element 0) LHS 24 Port Sideplane Config CRC 0x11EEFEAF (Sled 1 Element 0, Sled 2 Element 0) LHS 36 Port Expander VPD Structure 0x06 (Sled 1 Element 1, Sled 2 Element 1) LHS 36 Port Expander VPD CRC 0x2737A206 (Sled 1 Element 1, Sled 2 Element 1) 12 Firmware SSU Component Sub-Component Version Number LHS 36 Port Sideplane Config CRC 0x687FE3F1 (Sled 1 Element 1, Sled 2 Element 1) MMU System Firmware Versions The following table provides a version list of the firmware components, as the product leaves the factory, for the MMU 2U24 storage system and the MMU 5U84 storage system released under USM 3.20 for the MMU enclosure. MMU Component Firmware Sub-Component Version Number Bootloader 05.03 Firmware 3.5.0.25 (0x3519) VPD Version 0x06 VPD CRC 0xBAA55828 Config CRC 0xF6BA98EA GEM CPLD 0x14 Power CPLD 0x00176CF8 CPLD 0x10 VPD Version 0x0C VPD CRC 0x8BFFC5AD Firmware 3.11 VPD Version 0x03 VPD CRC 0x6B58AD13 Bootloader 05.03 Firmware 3.5.0.25 (0x3519) VPD Version 0x06 VPD CRC 0xBAA55828 Config CRC 0xF6BA98EA GEM CPLD 0x14 Power CPLD 0x00176CF8 CPLD 0x05 2U24 Storage System EBOD I/O Module Midplane 580W PCM 5U84 Storage System EBOD I/O Module Midplane 13 Firmware MMU Component Firmware Sub-Component Version Number VPD Version 0x0F VPD CRC 0x0E74E375 Primary 2.1E Secondary 2.28 EEPROM 2.00 VPD Version 0x03 XYR VPD CRC 0x486003DF Cooling Fan Module Firmware 2.3.6 (Config 0960837-04) Sideplane Bootloader 06.10 Firmware 3.5.0.25 (0x3519) RHS Sideplane CPLD 0x10 2814W PCM (Sled 1 Element 2, Sled 2 Element 2) (Sled 1 Element 3, Sled 2 Element 3) RHS 24 Port Expander VPD Structure 0x06 (Sled 1 Element 2, Sled 2 Element 2) RHS 24 Port Expander VPD CRC 0x152E4AD9 (Sled 1 Element 2, Sled 2 Element 2) RHS 24 Port Sideplane Config CRC 0xFA337B92 (Sled 1 Element 2, Sled 2 Element 2) RHS 36 Port Expander VPD Structure 0x06 (Sled 1 Element 3, Sled 2 Element 3) RHS 36 Port Expander VPD CRC 0x38B21CF7 (Sled 1 Element 3, Sled 2 Element 3) RHS 36 Port Sideplane Config CRC 0x6591A901 (Sled 1 Element 3, Sled 2 Element 3) LHS Sideplane CPLD 0x10 (Sled 1 Element 0, Sled 2 Element 0) (Sled 1 Element 1, Sled 2 Element 1) LHS 24 Port Expander VPD Structure 0x06 (Sled 1 Element 0, Sled 2 Element 0) 14 Firmware MMU Component Firmware Sub-Component Version Number LHS 24 Port Expander VPD CRC 0xF027D510 (Sled 1 Element 0, Sled 2 Element 0) LHS 24 Port Sideplane Config CRC 0x11EEFEAF (Sled 1 Element 0, Sled 2 Element 0) LHS 36 Port Expander VPD Structure 0x06 (Sled 1 Element 1, Sled 2 Element 1) LHS 36 Port Expander VPD CRC 0x2737A206 (Sled 1 Element 1, Sled 2 Element 1) LHS 36 Port Sideplane Config CRC 0x687FE3F1 (Sled 1 Element 1, Sled 2 Element 1) x86 firmware components MMU Component Firmware Sub-component FW/BIOS Intel 2U - FDR (H2000JFF) BIOS SE5C600.86B.02.02.0002 BMC/Op Code/Boot Code 1.21.6038/1.21.6038/01.17 ME FW 02.01.07.328 SDR Rev SDR Package 1.12 MB Mellanox IB/GbE HCA - MT4099 INCX-3I358C10551_CX-3 2.11.1308 LSI SAS HBA SAS9207-8e BIOS: 7.25.00.00 FW: 13.00.57.00-0d.43.d1.05 Rack Component Firmware Versions This table provides a list of the firmware versions for the rack switches and PDUs as the product leaves the factory. Rack Component (Model Number) FW Mellanox 36 Port InfiniBand Switch (6025 FDR) 9.2.8000 Brocade 24 Port LAN Switch (ICX-6610-24) 08.0.10 Brocade 48 Port LAN Switch (ICX-6610-48) 08.0.10 15 Firmware Disk Drive Firmware Versions This table provides a list of the supported disk drive firmware version data as the product leaves the factory. Drive Model FW Cray 100GB SSD (ST100FM0093) [SSU] XGSH Cray 600GB HDD (ST600MM0006) [MMU 2U24 EBOD] XLGF Cray 900GB HDD (ST900MM0006) [MMU 2U24 EBOD] XLGF Cray 6TB HDD (ST1600NM0034) [SSU & ESU] E001 Cray 4TB HDD (ST4000NM0023) [SSU & ESU] XMGG Cray 2TB HDD (ST2000NM0034) [SSU & ESU] E001 Cray 300GB HDD (ST9300653SS) [MMU 5U84 EBOD)] XRY2 16 Supported 1600/900 Hardware Components 7 Supported 1600/900 Hardware Components Component Description /Model No. Part No. Feature Code 100GSS-SAS6-RPS MDS HUSSL4010ASS600 0985751 CS-ES-100GSS-SAS6-RPS 100GB SFF SAS Ralston Peak B SSD (for MDS) 0990394 CS-ES-100GSS-SAS-RPSB 100GB SFF SAS Ralston Peak B SSD (for SSU) 0985504 CS-UD-100GSS-SAS-RPSB 100GB SFF SAS T10 Ralston Peak B SSD (for SSU) 0998204 CS-UD-100GSS-SAS-T10-RPSB 100GB SFF SAS Gibson HE SSD (for MDS) 1001956 CS-ES-100GSS-SAS-GIBH 100GB SFF SAS Gibson HE SSD (for SSU) 0994853 CS-UD-100GSS-SAS-GIBH 100GB SFF SAS T10 Gibson HE SSD (for SSU) 0995253 CS-UD-100GSS-SAS-T10-GIBH 450 GB SFF SAS Compass (for MDS) 0985747 CS-ES-450G10-SAS-10K5 600 GB SFF SAS Compass (for MDS) 0985749 CS-ES-600G10-SAS-10K5 450GB 2.5" Lightning SAS drive (for MDS) 0990378 CS-ES-450G10-SAS-10K6 600GB 2.5" Lightning SAS drive (for MDS) 0990380 CS-ES-600G10-SAS-10K6 100GB SFF SAS HUSSL4010ASS600 SSD (for SSU) 0985503 CS-UD-100GSS-SAS-RPS 300GB SFF SAS T10 Yellowjacket (for SSU) 0985502 CS-UD-300G15-SAS-15K3 300GB 2.5" 15K SAS (for SSU) 0990017 CS-HNW-300G15-SAS-15K3 1TB Muskie+ FSAS (for SSU) 0985497 CS-UD-1T72-SAS-CESP 2TB Muskie+ FSAS (for SSU) 0985498 CS-UD-2T72-SAS-CESP 1TB Megalodon FSAS (for SSU) 1000486 CS-UD-1T72-SAS-CES3 2TB Megalodon FSAS (for SSU) 0991420 CS-UD-2T72-SAS-CES3 2TB Megalodon T10 FSAS (for SSU) 0998561 CS-UD-2T72-SAS-T10-CES3 3TB Megalodon FSAS (for SSU) 0991422 CS-UD-3T72-SAS-CES3 3TB Megalodon T10 FSAS (for SSU) 0995255 CS-UD-3T72-SAS-T10-CES3 3TB Megladon FSAS (for SSU & ESU) 0995107 CS-HNW-3T72-SAS6-CES3-DD 4TB Megalodon FSAS (for SSU) 0991424 CS-UD-4T72-SAS-CES3 4TB Megalodon T10 FSAS (for SSU) 0998562 CS-UD-4T72-SAS-T10-CES3 2TB Mars K FSAS (for SSU) 0985499 CS-UD-2T72-SAS-MRK 3TB Mars K FSAS (for SSU) 985500 CS-UD-3T72-SAS-MRK 17 Supported 1600/900 Hardware Components Component Description /Model No. Part No. Feature Code 3TB Mars K T10 FSAS (for SSU) 1006268 CS-UD-3T72-SAS-T10-MRK 2TB Mars K FSAS (for SSU & ESU) 0991405 CS-HNW-2T72-SAS6-MRK-DD 3TB Mars K FSAS (for SSU & ESU) 0991407 CS-HNW-3T72-SAS6-MRK-DD 3TB Mantaray FSAS (for SSU) 0985501 CS-UD-3T72-SAS-CES2 4TB Verdi FSAS (for SSU) 0988066 CS-UD-4T72-SAS-RE 4TB Verdi T10 FSAS (for SSU) 0995256 CS-UD-4T72-SAS-T10-RE 4TB Verdi FSAS (for SSU & ESU) 0991466 CS-HNW-4T72-SAS6-RE-DD 4U CSSM Cluster Management Node, Quad Redundant nodes with shared, high performance MDT Storage, 24 x 600GB SFF SAS 0997813 CS-2425-MMU2-13TB2 7U CSSM Cluster Management Node, Quad Redundant nodes with shared, high performance MDT Storage, 84 x 300GB 15k SFF SAS 0997815 CS-2584-MMU2-24T6 Sonexion 1600 Application Controller 32GB Turbo (E5-2648L) 0977614 Sonexion 1600-AC-T-32-FRU 5U 84 Drive HA OSS Turbo Storage Server Node, Dual 0998163 Sonexion 1600T Server Nodes, with Dual Host Ports , 82 x 1TB FSAS HDD, 2 x 100G SSD CS-2584-1600ACT-82TB 5U 84 Drive HA OSS Turbo Storage Server Node, Dual 1001690 Sonexion 1600T Server Nodes, with Dual Host Ports , 82 x 2TB FSAS HDD, 2 x 100G SSD CS-2584-1600ACT-164TB 5U 84 Drive HA OSS Turbo Storage Server Node, Dual 0995264 Sonexion 1600T Server Nodes, with Dual Host Ports , 82 x 2TB T10 Format FSAS HDD, 2 x 100G SSD CS-2584-1600ACT-GR-T10-164TB 5U 84 Drive HA OSS Turbo Storage Server Node, Dual 1001691 Sonexion 1600T Server Nodes, with Dual Host Ports , 82 x 3TB FSAS HDD, 2 x 100G SSD CS-2584-1600ACT-246TB 5U 84 Drive HA OSS Turbo Storage Server Node, Dual 0995265 Sonexion 1600T Server Nodes, with Dual Host Ports , 82 x 3TB T10 Format FSAS HDD, 2 x 100G SSD CS-2584-1600ACT-GR-T10-246TB 5U 84 Drive HA OSS Turbo Storage Server Node, Dual 1001692 Sonexion 1600T Server Nodes, with Dual Host Ports , 82 x 4TB FSAS HDD, 2 x 100G SSD CS-2584-1600ACT-328TB 5U 84 Drive HA OSS Turbo Storage Server Node, Dual 0995266 Sonexion 1600T Server Nodes, with Dual Host Ports , 82 x 4TB T10 Format FSAS HDD, 2 x 100G SSD CS-2584-1600ACT-GR-T10-328TB 5U 84 Drive HA OSS Expansion Node,, with Dual SAS Host Ports, 82 x 2TB FSAS HDD, 2 x 0.5M MiniSAS 1001693 CS-2584-ESU-164TB 5U 84 Drive HA OSS Expansion Node,, with Dual SAS Host Ports, 82 x 2TB T10 Format FSAS HDD, 2 x 0.5M MiniSAS 0995267 CS-2584-ESU-GR-T10-164TB 18 Supported 1600/900 Hardware Components Component Description /Model No. Part No. Feature Code 5U 84 Drive HA OSS Expansion Node,, with Dual SAS Host Ports, 82 x 3TB FSAS HDD, 2 x 0.5M MiniSAS 1001694 CS-2584-ESU-246TB 5U 84 Drive HA OSS Expansion Node,, with Dual SAS Host Ports, 82 x 3TB T10 Format FSAS HDD, 2 x 0.5M MiniSAS 0995268 CS-2584-ESU-GR-T10-246TB 5U 84 Drive HA OSS Expansion Node,, with Dual SAS Host Ports, 82 x 4TB FSAS HDD, 2 x 0.5M MiniSAS 1001695 CS-2584-ESU-328TB 5U 84 Drive HA OSS Expansion Node,, with Dual SAS Host Ports, 82 x 4TB T10 Format FSAS HDD, 2 x 0.5M MiniSAS 0995269 CS-2584-ESU-GR-T10-328TB 2 x Mellanox Infiniband 36-Port Switch MIS5035Q-1SFC managed - Dual PSU 0969899 CS-SW-IB1-36-2 2 x Mellanox Infiniband 18-Port Switch MIS5023Q-1BFR unmanaged - Single PSU 0974643 CS-SW-IB1-18-2 2 x Mellanox 36-Port Infiniband switch (2xMSX6025F-1SFR or -1SFS, 2xMSX60-PF) - unmanaged - NOT Ethernet capable 0969902 CS-SW-IB2-FDR-36-2 2 x Mellanox 36-Port 40Gb Ethernet switch (2xMSX1036F-1SFR) - Dual PSU 0986818 CS-SW-ETH1-40G-M-36-2 2 x Arista 7050Q 16xQSFP+ & 8xSFP+ switch, Dual 460W AC PSUs 0990599 CS-SW-ETH2-40G-AR-16-2 2 x Force10 10Gbe Switch 48 port SV-S4810PACR-2 - Dual PSU 0969904 CS-SW-10G1-48-2 Dual - Netgear ProSafe GbE L3 48 port managed switch GSM7352S-200 - Single PSU 0991044 CS-SW-MGT1-48-2 Dual - Netgear ProSafe GbE L3 24 port managed switch GSM7328S-200 - Single PSU 0984165 CS-SW-MGT1-24-2 CIFS/NFS Gateway (CNG) Solution - 2U Quad Sandy Bridge server system. Four Node Server, each node connectivity is single QDR IB connection to the Sonexion and single 40GbE Ethernet connection to the CIFS/NFS client side 0991409 CS-CNGW-JFF-2680-Q40GBEQQDR CIFS/NFS Gateway (CNG) Solution - 2U Quad Sandy Bridge 1003417 server system. Four Node Server, each node connectivity is single 40GbitE or QDR/FDR IB connection to the Sonexion and single 40GbE Ethernet connection to the CIFS/NFS client CS-CNGW-JFF-2680-Q40GBEQ40GBE 2U 24 High Performance Single Shelf Cluster Manager, 2 x CS1K Application Controllers, 16 x 10K 450GB HDD, 2 x 764W PSUs 0920003 CS-2425-MMU-1KAC-7T2 4U 24 High Performance Single Shelf Cluster Storage, 2 x CS1K Application Controllers, 21 x 2TB HDD, 2 x 300GB 15k HDD. 4 x PSUs 0920004 CS-2435-SSU-1KAC-40TB 4U 24 High Performance Single Shelf Cluster Storage, 2 x CS1K Application Controllers, 21 x 3TB HDD, 2 x 300GB 15k HDD. 4 x PSUs 0920005 CS-2435-SSU-1KAC-60TB 19 Supported 1600/900 Hardware Components Component Description /Model No. Part No. Feature Code 4U 24 High Performance Single Shelf Cluster Storage, 2 x CS1K Application Controllers, 21 x 4TB HDD, 2 x 300GB 15k HDD. 4 x PSUs 0920006 CS-2435-SSU-1KAC-80TB 4U 24 Drive HA OSS Expansion Node,, with Dual SAS Host Ports, 21 x 2TB FSAS HDD, 2 x 1M & 2 x 2M MiniSAS 0920007 CS-2435-ESU-40TB 4U 24 Drive HA OSS Expansion Node,, with Dual SAS Host Ports, 21 x 3TB FSAS HDD, 2 x 1M & 2 x 2M MiniSAS 0920008 CS-2435-ESU-60TB 4U 24 Drive HA OSS Expansion Node,, with Dual SAS Host Ports, 21 x 4TB FSAS HDD, 2 x 1M & 2 x 2M MiniSAS 0920009 CS-2435-ESU-80TB 2 x Brocade GbE L2 24 Port Managed Switch ICX6430-24 Single PSU 0991096 CS-SW-MGT2-24-2 2 x Brocade GbE L2 48 Port Managed Switch ICX6430-48 Single PSU 0991097 CS-SW-MGT2-48-2 Sonexion 900 Application Controller 32GB (E5-2609 + Ethernet 0991184 Port) Sonexion 900-AC-32-ETHS-FRU CS1000 Application Controller 16GB (E5-2609) Sonexion 900-AC-16-FRU 0989564 20