Transcript
Sonexion 1.5 1600/900 Release Notes
Contents
Contents 1 About Sonexion 1.5 1600/900 Release Notes........................................................................................................3 2 Software Versions and Requirements....................................................................................................................4 3 What’s New for Sonexion 1.5.0 1600/900...............................................................................................................6 4 Known Issues for Sonexion 1.5.0...........................................................................................................................8 5 CSCLI Changes in Release 1.5 1600/900..............................................................................................................9 6 Firmware...............................................................................................................................................................11 7 Supported 1600/900 Hardware Components ......................................................................................................17
2
About Sonexion 1.5 1600/900 Release Notes
1
About Sonexion 1.5 1600/900 Release Notes
This publication includes information about the environment, software requirements, supported upgrade paths, bug fixes, notices, known issues, list of code versions, and component firmware versions for this release of the Sonexion 1600 or 900 system. Table 1. Record of Revision: publication S-2533-15 Publication number
Date
Note
S-2533-15a
September 2014
Sonexion 2000 version
S-2533-15b
June 2015
Sonexion 1300/1600 version
Sonexion 1600 System
Sonexion 900 System
3
Software Versions and Requirements
2
Software Versions and Requirements
In order to upgrade to Sonexion 1.5.0, the system must already be running release 1.4.0.
CSSM Version Version
Current Version
CSSM
CSSM 1.5.0 (SU07) Build v. r23586, 2015-05-06 USM 3.20
Sonexion 2000
X
Sonexion 1600
X
Sonexion 900
X
Lustre Server (x86_64 Architecture) Version
Current Version
Operating System
Scientific Linux 6.2 (Carbon)
Kernel
2.6.32-220.7.1.el6.lustre.4230
File System
2.1.0.x5-133_2.6.32_220.7.1.el6.lustre.4230.x86_64_gce10faa
Summary List of Requirements The following table summarizes the public Lustre client support matrix. Lustre clients are closely tied to the distribution, Linux Kernel version, and are dependent on OFED drivers. Please consult with your Cray representative to confirm details of your specific client configuration. Client Version
Distributions
1.8.8-x1
Oracle Enterprise Linux 6.3
Oracle Enterprise Linux 6.4
1.8.9-wc
Scientific Linux 6.2
Scientific Linux 6.4
SUSE Linux Enterprise Server 11SP2
2.1.5-wc
Scientific Linux 6.2
Scientific Linux 6.4
SUSE Linux Enterprise Server 11SP1
2.4.1-wc
N/A
Scientific Linux 6.4
SUSE Linux Enterprise Server 11SP2
4
Software Versions and Requirements
Management Node
Network Infrastructure Requirements*
DHCP Server
Provides the management nodes’ IP addresses for browser connections.
NTP Server
Synchronizes clocks across the cluster’s nodes.
DNS Server
Resolves LDAP and NTP host names on the management nodes.
* Manual workarounds may be available for environments without these servers. Please contact your support representative. Port 3306 must be open between the browser and the CSSM server in order to view Lustre performance information.
Supported Browsers Sonexion supports the latest versions of Chrome, Firefox, and Safari browsers under Windows, Linux, and Mac OS operating systems. Please make sure the latest Java package(s) are installed for full management GUI functionality.
Supported Upgrade Paths
Release 1.5 supports upgrading from release 1.4.0 to release 1.5.0 for the following product types: ●
Sonexion 900 MDRAID
●
Sonexion 1600 MDRAID
●
Sonexion 1600 GridRAID (formerly PDRAID)
The RAID type cannot be changed as part of the upgrade (i.e., MDRAID will stay MDRAID and GridRAID will stay GridRAID).
5
What’s New for Sonexion 1.5.0 1600/900
3
What’s New for Sonexion 1.5.0 1600/900
The following new features and improvements are part of Sonexion 1.5.0:
Introduction of new SSU hardware ●
Ivy Bridge-EP (Socket R) Xeon E5-2648L v2 CPU 10 Cores - 1.9GHz, 20 MByte cache
●
8.5GB/sec performance
●
Increased hardware utilization of SAS bandwidth
CNG (CIFS/NFS Gateway) Sonexion 1.5.0 systems can support optional dedicated hardware server nodes with CIFS2 Export and NFS Export capabilities. CNG support enables Lustre file system access to be exported to CIFS/SMB2 and NFS clients. The CNG feature allows the Lustre filesystem to be shared using enterprise clients (Windows, Mac and Linux), and to use enterprise NAS CIFS2 and NFS by providing parallel multi-client access through multiple CNG nodes. The Clustered Trivial Database (CTDB) file-sharing technology, which is part of Samba, provides shared access to Lustre files across multiple CNG nodes. The CNG feature provides the following: ●
Full support for clusters
●
Chassis configuration with either two or four CNG server nodes
●
Client access using CIFS/SMB2 or NFS protocol
●
Full installation support
●
Individual node operation as part of Samba CTDB cluster
●
Individual node boot from the MGMT node running without dedicated local disk storage
●
HA support – CNG server nodes manage file share locking between them
●
○
Multi-client access to the Lustre file system is supported and managed by the CTDB software
○
Clients may need to reconnect after failover
CIFS authentication is automatically configured to be the same as for Lustre clients ○
Lustre users can be configured via AD, LDAP or NIS
○
Individual shares may instead be configured for passwordless guest access
●
NFS clients automatically obtain the same user authorization as Lustre clients. Full installation support.
●
Full support bundle and log support
6
What’s New for Sonexion 1.5.0 1600/900
●
Full support for health monitoring
●
Full CSCLI support of the FRU inventory
●
Manual FRU replacement of the chassis hosting CNG nodes
●
Full support for changing ECN IP addresses of CNG
●
Fully-featured share configuration including security
●
Automatic configuration for supported LCN and ECN interfaces
●
LCN: Full support for 40GbE and QDR/FDR IB
●
ECN: Full support for 10GbE and 40GbE
Other Changes ●
Mellanox HBA firmware update for the MMU
●
Support for Non-NSS Lustre upcall
●
The Lustre Users functionality page is moved from the CSSM - Pre-Shipment Installation (also known as Customer Wizard) to the Configure tab in CSSM.
●
Support for changing Lustre Users settings in Daily Mode from the GUI and CSCLI. The Configure tab in daily mode has NIS, LDAP (including multiple servers), and separate, simplified settings for AD. It also includes the option to define users directly on the Sonexion system by uploading /etc/passwd and /etc/ group files. All these settings can be edited or changed as often as desired.
●
Support for local user/group definitions for Lustre users
●
Support for multiple Lustre upcall methods simultaneously, for example, NIS, LDAP, etc.
●
Support for changing Lustre Users settings in Daily Mode from the GUI and CSCLI
●
Support LDAP over SSL for Lustre users
●
Support for multiple LDAP servers
●
Dual Management Network (DMN) support:
●
●
●
○
DMN is scalable
○
Provides redundancy at both the OS layer and the BMC layer
○
Easily upgraded or repaired
New Lustre features: ○
Requires minimal support to maintain
○
New group upcall utility supporting several authentication methods (files, LDAP(s), NIS, NIS+) simultaneously.
New Sonexion Switches: ○
Mellanox SX1024
○
Intel TrueScale 12300
RAS: The Initial RAS release provides support for Disk Drive failures in all Cray developed storage enclosures, including all SSDs and HDDs. Note that the quad server of the MMU is not yet supported, but the MMU storage is supported.
7
Known Issues for Sonexion 1.5.0
4
Known Issues for Sonexion 1.5.0
Known issues for this release are listed below, with workarounds. Description
Workaround
The Service Action list is text rather than graphical icons and clicking on a service action does not display the service procedure in the main panel (view is empty).
If the Service Action list is text rather than graphical icons and clicking on a service action does not display the service procedure in the main panel - please clear the browser cache for all time and refresh page.
The Dashboard’s File System Throughput Chart view If the File System Throughput Chart is unavailable may disappear when Chrome is updated to the latest (that is, the view is empty), clear the browser cache for version. all time and refresh page. RAS action items may not automatically clean up after being archived.
Reloading the page or clicking on another actionable item will update the displayed Action List and cleanup archived items.
Build number and date tooltip blocked by LMT (Lustre Monitoring Tool) screen
No workaround at this time
8
CSCLI Changes in Release 1.5 1600/900
5
CSCLI Changes in Release 1.5 1600/900
The following commands were added to this release:
CSCLI Changes Addition/ Change
CSCLI Command
Description
Component
1. Added
ibstat_check
Disables/Enables HA's probing of the high speed network
HA stack
2. Added
manage_guest
Manages the guest account, a built-in account for read-only administrative use.
User Management
3. Added
show_node_versi ons
Changes the image for a diskless node
System upgrades
4. Added
service_console
Enables or disables the service console or displays the state of the service console
Serviceability
5. Added
lustre_users
Lustre users command in Daily Mode. Many commands have changed and several commands have been added. These commands can now be performed from the Daily Mode.
Advanced User Authentication
Displays pdsh-style node names and the time window in minutes
Support bundle settings
support_bundle 6. Added support_bund collect le subcommand support_bundle show
Displays triggers that initiate automatic bundle collection, a list of support bundles collected and the purge limit
support_bundle export
Displays the bundle ID
support_bundle set
Displays purge limit for the support bundle and triggers that initiate automatic bundle collection
7. Changed/ Updated
Advanced Users Commands (Lustre Users Commands)
8. Changed
‘Customer Installation’ is referred to as ‘site configuration’
9. Moved
Lustre users setup from ‘Site Configuration’ (previously called ‘Customer Installation’)
9
CSCLI Changes in Release 1.5 1600/900
Addition/ Change
CSCLI Command
Description
Component
1 Feature added in The rebuild_rate command displays the numerical values when the rebuild is in 0. rebuild_rate progress command 1 Updated 1.
service_console
1 Added 2.
cscli rack
Extends the functionality of cscli get_rack_position and set_rack_position
Rack
1 Added 3.
UD Commands
Unresponsive Drives Commands
Disk Drive
dm
DM Service Configuration Management
dwd
DWD- Daemon Configuration Management
Added or Changed CNG - CSCLI Commands N Addition/ o. Change
CSCLI Command
Description
Component
1. Added
cng
Management of the CIFS/NFS Gateway (CNG)
CIFS/NFS
2. Changed
‘Exporter nodes’ are referred to as ‘CNG nodes’ in the content of the document. The cscli export command is deprecated. Please use cscli cng instead for all --help outputs of cscli export, including all its subcommands. If the cscli export command is used the following message will be displayed: “This command is deprecated. Please use 'cscli cng' instead.”
3. Changed
The cscli cng network command is deprecated. Please use cscli the cng clientgroup command instead.The cscli cng share cifs network command is deprecated. Please use the cscli cng share cifs clientgroup command instead. The cscli cng share nfs network command is deprecated. Please use the cscli cng share nfs clientgroup command instead.
10
Firmware
6
Firmware
SSU System Firmware Versions for Sonexion 1.5.0 The following table provides a version list of the firmware components for the SSU 5U84 storage system released under USM 3.20 for the SSU enclosure. SSU Component
Sub-Component
Version Number
Sonexion 900/1600 Application Controller
Bootloader
05.03
Firmware
3.5.0.25 (0x3519)
VPD Structure
0x06
VPD CRC
0xEE3504B4
Config CRC
0xD1B030A4
GEM CPLD
0x17
BIOS
0.46.0001
BMC Boot
2.0.0001
BMC Root
2.0.000A
Main CPLD
0.17.0004
Intel Management Engine
1
Mellanox IB/Ethernet HCA Firmware
2.30.8000
PLX EEPROM
VF22-LF-CRC: 0x98229A3E
CPLD
0x05
VPD Version
0x0F
VPD CRC
0x0E74E375
Primary
2.1E
Secondary
2.28
EEPROM
2.00
VPD Version
0x03
XYR VPD CRC
0x486003DF
Firmware
2.3.6 (Config 0960837-04)
Midplane
2814W PCM
Cooling Fan Module
11
Firmware
SSU Component
Sub-Component
Version Number
Sideplane
Bootloader
06.10
Firmware
3.5.0.25 (0x3519)
RHS Sideplane CPLD
0x10
(Sled 1 Element 2, Sled 2 Element 2) (Sled 1 Element 3, Sled 2 Element 3) RHS 24 Port Expander VPD Structure
0x06
(Sled 1 Element 2, Sled 2 Element 2) RHS 24 Port Expander VPD CRC
0x152E4AD9
(Sled 1 Element 2, Sled 2 Element 2) RHS 24 Port Sideplane Config CRC
0xFA337B92
(Sled 1 Element 2, Sled 2 Element 2) RHS 36 Port Expander VPD Structure
0x06
(Sled 1 Element 3, Sled 2 Element 3) RHS 36 Port Expander VPD CRC
0x38B21CF7
(Sled 1 Element 3, Sled 2 Element 3) RHS 36 Port Sideplane Config CRC
0x6591A901
(Sled 1 Element 3, Sled 2 Element 3) LHS Sideplane CPLD
0x10
(Sled 1 Element 0, Sled 2 Element 0) (Sled 1 Element 1, Sled 2 Element 1) LHS 24 Port Expander VPD Structure
0x06
(Sled 1 Element 0, Sled 2 Element 0) LHS 24 Port Expander VPD CRC
0xF027D510
(Sled 1 Element 0, Sled 2 Element 0) LHS 24 Port Sideplane Config CRC
0x11EEFEAF
(Sled 1 Element 0, Sled 2 Element 0) LHS 36 Port Expander VPD Structure
0x06
(Sled 1 Element 1, Sled 2 Element 1) LHS 36 Port Expander VPD CRC
0x2737A206
(Sled 1 Element 1, Sled 2 Element 1)
12
Firmware
SSU Component
Sub-Component
Version Number
LHS 36 Port Sideplane Config CRC
0x687FE3F1
(Sled 1 Element 1, Sled 2 Element 1)
MMU System Firmware Versions The following table provides a version list of the firmware components, as the product leaves the factory, for the MMU 2U24 storage system and the MMU 5U84 storage system released under USM 3.20 for the MMU enclosure. MMU Component
Firmware Sub-Component
Version Number
Bootloader
05.03
Firmware
3.5.0.25 (0x3519)
VPD Version
0x06
VPD CRC
0xBAA55828
Config CRC
0xF6BA98EA
GEM CPLD
0x14
Power CPLD
0x00176CF8
CPLD
0x10
VPD Version
0x0C
VPD CRC
0x8BFFC5AD
Firmware
3.11
VPD Version
0x03
VPD CRC
0x6B58AD13
Bootloader
05.03
Firmware
3.5.0.25 (0x3519)
VPD Version
0x06
VPD CRC
0xBAA55828
Config CRC
0xF6BA98EA
GEM CPLD
0x14
Power CPLD
0x00176CF8
CPLD
0x05
2U24 Storage System EBOD I/O Module
Midplane
580W PCM
5U84 Storage System EBOD I/O Module
Midplane
13
Firmware
MMU Component
Firmware Sub-Component
Version Number
VPD Version
0x0F
VPD CRC
0x0E74E375
Primary
2.1E
Secondary
2.28
EEPROM
2.00
VPD Version
0x03
XYR VPD CRC
0x486003DF
Cooling Fan Module
Firmware
2.3.6 (Config 0960837-04)
Sideplane
Bootloader
06.10
Firmware
3.5.0.25 (0x3519)
RHS Sideplane CPLD
0x10
2814W PCM
(Sled 1 Element 2, Sled 2 Element 2) (Sled 1 Element 3, Sled 2 Element 3) RHS 24 Port Expander VPD Structure
0x06
(Sled 1 Element 2, Sled 2 Element 2) RHS 24 Port Expander VPD CRC
0x152E4AD9
(Sled 1 Element 2, Sled 2 Element 2) RHS 24 Port Sideplane Config CRC
0xFA337B92
(Sled 1 Element 2, Sled 2 Element 2) RHS 36 Port Expander VPD Structure
0x06
(Sled 1 Element 3, Sled 2 Element 3) RHS 36 Port Expander VPD CRC
0x38B21CF7
(Sled 1 Element 3, Sled 2 Element 3) RHS 36 Port Sideplane Config CRC
0x6591A901
(Sled 1 Element 3, Sled 2 Element 3) LHS Sideplane CPLD
0x10
(Sled 1 Element 0, Sled 2 Element 0) (Sled 1 Element 1, Sled 2 Element 1) LHS 24 Port Expander VPD Structure
0x06
(Sled 1 Element 0, Sled 2 Element 0)
14
Firmware
MMU Component
Firmware Sub-Component
Version Number
LHS 24 Port Expander VPD CRC
0xF027D510
(Sled 1 Element 0, Sled 2 Element 0) LHS 24 Port Sideplane Config CRC
0x11EEFEAF
(Sled 1 Element 0, Sled 2 Element 0) LHS 36 Port Expander VPD Structure
0x06
(Sled 1 Element 1, Sled 2 Element 1) LHS 36 Port Expander VPD CRC
0x2737A206
(Sled 1 Element 1, Sled 2 Element 1) LHS 36 Port Sideplane Config CRC
0x687FE3F1
(Sled 1 Element 1, Sled 2 Element 1)
x86 firmware components MMU Component
Firmware Sub-component
FW/BIOS
Intel 2U - FDR (H2000JFF)
BIOS
SE5C600.86B.02.02.0002
BMC/Op Code/Boot Code
1.21.6038/1.21.6038/01.17
ME FW
02.01.07.328
SDR Rev
SDR Package 1.12
MB Mellanox IB/GbE HCA - MT4099 INCX-3I358C10551_CX-3
2.11.1308
LSI SAS HBA SAS9207-8e
BIOS: 7.25.00.00 FW: 13.00.57.00-0d.43.d1.05
Rack Component Firmware Versions This table provides a list of the firmware versions for the rack switches and PDUs as the product leaves the factory. Rack Component (Model Number)
FW
Mellanox 36 Port InfiniBand Switch (6025 FDR)
9.2.8000
Brocade 24 Port LAN Switch (ICX-6610-24)
08.0.10
Brocade 48 Port LAN Switch (ICX-6610-48)
08.0.10
15
Firmware
Disk Drive Firmware Versions This table provides a list of the supported disk drive firmware version data as the product leaves the factory. Drive Model
FW
Cray 100GB SSD (ST100FM0093) [SSU]
XGSH
Cray 600GB HDD (ST600MM0006) [MMU 2U24 EBOD]
XLGF
Cray 900GB HDD (ST900MM0006) [MMU 2U24 EBOD]
XLGF
Cray 6TB HDD (ST1600NM0034) [SSU & ESU]
E001
Cray 4TB HDD (ST4000NM0023) [SSU & ESU]
XMGG
Cray 2TB HDD (ST2000NM0034) [SSU & ESU]
E001
Cray 300GB HDD (ST9300653SS) [MMU 5U84 EBOD)]
XRY2
16
Supported 1600/900 Hardware Components
7
Supported 1600/900 Hardware Components
Component Description /Model No.
Part No.
Feature Code
100GSS-SAS6-RPS MDS HUSSL4010ASS600
0985751
CS-ES-100GSS-SAS6-RPS
100GB SFF SAS Ralston Peak B SSD (for MDS)
0990394
CS-ES-100GSS-SAS-RPSB
100GB SFF SAS Ralston Peak B SSD (for SSU)
0985504
CS-UD-100GSS-SAS-RPSB
100GB SFF SAS T10 Ralston Peak B SSD (for SSU)
0998204
CS-UD-100GSS-SAS-T10-RPSB
100GB SFF SAS Gibson HE SSD (for MDS)
1001956
CS-ES-100GSS-SAS-GIBH
100GB SFF SAS Gibson HE SSD (for SSU)
0994853
CS-UD-100GSS-SAS-GIBH
100GB SFF SAS T10 Gibson HE SSD (for SSU)
0995253
CS-UD-100GSS-SAS-T10-GIBH
450 GB SFF SAS Compass (for MDS)
0985747
CS-ES-450G10-SAS-10K5
600 GB SFF SAS Compass (for MDS)
0985749
CS-ES-600G10-SAS-10K5
450GB 2.5" Lightning SAS drive (for MDS)
0990378
CS-ES-450G10-SAS-10K6
600GB 2.5" Lightning SAS drive (for MDS)
0990380
CS-ES-600G10-SAS-10K6
100GB SFF SAS HUSSL4010ASS600 SSD (for SSU)
0985503
CS-UD-100GSS-SAS-RPS
300GB SFF SAS T10 Yellowjacket (for SSU)
0985502
CS-UD-300G15-SAS-15K3
300GB 2.5" 15K SAS (for SSU)
0990017
CS-HNW-300G15-SAS-15K3
1TB Muskie+ FSAS (for SSU)
0985497
CS-UD-1T72-SAS-CESP
2TB Muskie+ FSAS (for SSU)
0985498
CS-UD-2T72-SAS-CESP
1TB Megalodon FSAS (for SSU)
1000486
CS-UD-1T72-SAS-CES3
2TB Megalodon FSAS (for SSU)
0991420
CS-UD-2T72-SAS-CES3
2TB Megalodon T10 FSAS (for SSU)
0998561
CS-UD-2T72-SAS-T10-CES3
3TB Megalodon FSAS (for SSU)
0991422
CS-UD-3T72-SAS-CES3
3TB Megalodon T10 FSAS (for SSU)
0995255
CS-UD-3T72-SAS-T10-CES3
3TB Megladon FSAS (for SSU & ESU)
0995107
CS-HNW-3T72-SAS6-CES3-DD
4TB Megalodon FSAS (for SSU)
0991424
CS-UD-4T72-SAS-CES3
4TB Megalodon T10 FSAS (for SSU)
0998562
CS-UD-4T72-SAS-T10-CES3
2TB Mars K FSAS (for SSU)
0985499
CS-UD-2T72-SAS-MRK
3TB Mars K FSAS (for SSU)
985500
CS-UD-3T72-SAS-MRK
17
Supported 1600/900 Hardware Components
Component Description /Model No.
Part No.
Feature Code
3TB Mars K T10 FSAS (for SSU)
1006268
CS-UD-3T72-SAS-T10-MRK
2TB Mars K FSAS (for SSU & ESU)
0991405
CS-HNW-2T72-SAS6-MRK-DD
3TB Mars K FSAS (for SSU & ESU)
0991407
CS-HNW-3T72-SAS6-MRK-DD
3TB Mantaray FSAS (for SSU)
0985501
CS-UD-3T72-SAS-CES2
4TB Verdi FSAS (for SSU)
0988066
CS-UD-4T72-SAS-RE
4TB Verdi T10 FSAS (for SSU)
0995256
CS-UD-4T72-SAS-T10-RE
4TB Verdi FSAS (for SSU & ESU)
0991466
CS-HNW-4T72-SAS6-RE-DD
4U CSSM Cluster Management Node, Quad Redundant nodes with shared, high performance MDT Storage, 24 x 600GB SFF SAS
0997813
CS-2425-MMU2-13TB2
7U CSSM Cluster Management Node, Quad Redundant nodes with shared, high performance MDT Storage, 84 x 300GB 15k SFF SAS
0997815
CS-2584-MMU2-24T6
Sonexion 1600 Application Controller 32GB Turbo (E5-2648L)
0977614
Sonexion 1600-AC-T-32-FRU
5U 84 Drive HA OSS Turbo Storage Server Node, Dual 0998163 Sonexion 1600T Server Nodes, with Dual Host Ports , 82 x 1TB FSAS HDD, 2 x 100G SSD
CS-2584-1600ACT-82TB
5U 84 Drive HA OSS Turbo Storage Server Node, Dual 1001690 Sonexion 1600T Server Nodes, with Dual Host Ports , 82 x 2TB FSAS HDD, 2 x 100G SSD
CS-2584-1600ACT-164TB
5U 84 Drive HA OSS Turbo Storage Server Node, Dual 0995264 Sonexion 1600T Server Nodes, with Dual Host Ports , 82 x 2TB T10 Format FSAS HDD, 2 x 100G SSD
CS-2584-1600ACT-GR-T10-164TB
5U 84 Drive HA OSS Turbo Storage Server Node, Dual 1001691 Sonexion 1600T Server Nodes, with Dual Host Ports , 82 x 3TB FSAS HDD, 2 x 100G SSD
CS-2584-1600ACT-246TB
5U 84 Drive HA OSS Turbo Storage Server Node, Dual 0995265 Sonexion 1600T Server Nodes, with Dual Host Ports , 82 x 3TB T10 Format FSAS HDD, 2 x 100G SSD
CS-2584-1600ACT-GR-T10-246TB
5U 84 Drive HA OSS Turbo Storage Server Node, Dual 1001692 Sonexion 1600T Server Nodes, with Dual Host Ports , 82 x 4TB FSAS HDD, 2 x 100G SSD
CS-2584-1600ACT-328TB
5U 84 Drive HA OSS Turbo Storage Server Node, Dual 0995266 Sonexion 1600T Server Nodes, with Dual Host Ports , 82 x 4TB T10 Format FSAS HDD, 2 x 100G SSD
CS-2584-1600ACT-GR-T10-328TB
5U 84 Drive HA OSS Expansion Node,, with Dual SAS Host Ports, 82 x 2TB FSAS HDD, 2 x 0.5M MiniSAS
1001693
CS-2584-ESU-164TB
5U 84 Drive HA OSS Expansion Node,, with Dual SAS Host Ports, 82 x 2TB T10 Format FSAS HDD, 2 x 0.5M MiniSAS
0995267
CS-2584-ESU-GR-T10-164TB
18
Supported 1600/900 Hardware Components
Component Description /Model No.
Part No.
Feature Code
5U 84 Drive HA OSS Expansion Node,, with Dual SAS Host Ports, 82 x 3TB FSAS HDD, 2 x 0.5M MiniSAS
1001694
CS-2584-ESU-246TB
5U 84 Drive HA OSS Expansion Node,, with Dual SAS Host Ports, 82 x 3TB T10 Format FSAS HDD, 2 x 0.5M MiniSAS
0995268
CS-2584-ESU-GR-T10-246TB
5U 84 Drive HA OSS Expansion Node,, with Dual SAS Host Ports, 82 x 4TB FSAS HDD, 2 x 0.5M MiniSAS
1001695
CS-2584-ESU-328TB
5U 84 Drive HA OSS Expansion Node,, with Dual SAS Host Ports, 82 x 4TB T10 Format FSAS HDD, 2 x 0.5M MiniSAS
0995269
CS-2584-ESU-GR-T10-328TB
2 x Mellanox Infiniband 36-Port Switch MIS5035Q-1SFC managed - Dual PSU
0969899
CS-SW-IB1-36-2
2 x Mellanox Infiniband 18-Port Switch MIS5023Q-1BFR unmanaged - Single PSU
0974643
CS-SW-IB1-18-2
2 x Mellanox 36-Port Infiniband switch (2xMSX6025F-1SFR or -1SFS, 2xMSX60-PF) - unmanaged - NOT Ethernet capable
0969902
CS-SW-IB2-FDR-36-2
2 x Mellanox 36-Port 40Gb Ethernet switch (2xMSX1036F-1SFR) - Dual PSU
0986818
CS-SW-ETH1-40G-M-36-2
2 x Arista 7050Q 16xQSFP+ & 8xSFP+ switch, Dual 460W AC PSUs
0990599
CS-SW-ETH2-40G-AR-16-2
2 x Force10 10Gbe Switch 48 port SV-S4810PACR-2 - Dual PSU
0969904
CS-SW-10G1-48-2
Dual - Netgear ProSafe GbE L3 48 port managed switch GSM7352S-200 - Single PSU
0991044
CS-SW-MGT1-48-2
Dual - Netgear ProSafe GbE L3 24 port managed switch GSM7328S-200 - Single PSU
0984165
CS-SW-MGT1-24-2
CIFS/NFS Gateway (CNG) Solution - 2U Quad Sandy Bridge server system. Four Node Server, each node connectivity is single QDR IB connection to the Sonexion and single 40GbE Ethernet connection to the CIFS/NFS client side
0991409
CS-CNGW-JFF-2680-Q40GBEQQDR
CIFS/NFS Gateway (CNG) Solution - 2U Quad Sandy Bridge 1003417 server system. Four Node Server, each node connectivity is single 40GbitE or QDR/FDR IB connection to the Sonexion and single 40GbE Ethernet connection to the CIFS/NFS client
CS-CNGW-JFF-2680-Q40GBEQ40GBE
2U 24 High Performance Single Shelf Cluster Manager, 2 x CS1K Application Controllers, 16 x 10K 450GB HDD, 2 x 764W PSUs
0920003
CS-2425-MMU-1KAC-7T2
4U 24 High Performance Single Shelf Cluster Storage, 2 x CS1K Application Controllers, 21 x 2TB HDD, 2 x 300GB 15k HDD. 4 x PSUs
0920004
CS-2435-SSU-1KAC-40TB
4U 24 High Performance Single Shelf Cluster Storage, 2 x CS1K Application Controllers, 21 x 3TB HDD, 2 x 300GB 15k HDD. 4 x PSUs
0920005
CS-2435-SSU-1KAC-60TB
19
Supported 1600/900 Hardware Components
Component Description /Model No.
Part No.
Feature Code
4U 24 High Performance Single Shelf Cluster Storage, 2 x CS1K Application Controllers, 21 x 4TB HDD, 2 x 300GB 15k HDD. 4 x PSUs
0920006
CS-2435-SSU-1KAC-80TB
4U 24 Drive HA OSS Expansion Node,, with Dual SAS Host Ports, 21 x 2TB FSAS HDD, 2 x 1M & 2 x 2M MiniSAS
0920007
CS-2435-ESU-40TB
4U 24 Drive HA OSS Expansion Node,, with Dual SAS Host Ports, 21 x 3TB FSAS HDD, 2 x 1M & 2 x 2M MiniSAS
0920008
CS-2435-ESU-60TB
4U 24 Drive HA OSS Expansion Node,, with Dual SAS Host Ports, 21 x 4TB FSAS HDD, 2 x 1M & 2 x 2M MiniSAS
0920009
CS-2435-ESU-80TB
2 x Brocade GbE L2 24 Port Managed Switch ICX6430-24 Single PSU
0991096
CS-SW-MGT2-24-2
2 x Brocade GbE L2 48 Port Managed Switch ICX6430-48 Single PSU
0991097
CS-SW-MGT2-48-2
Sonexion 900 Application Controller 32GB (E5-2609 + Ethernet 0991184 Port)
Sonexion 900-AC-32-ETHS-FRU
CS1000 Application Controller 16GB (E5-2609)
Sonexion 900-AC-16-FRU
0989564
20