Southwire 138kv Hv Cable Brochure

   EMBED


Share

Transcript

Know Your Options: 138 kV Power Cables 43 Section 4 Conductor material and size • Copper conductor common for larger loads • W  hen both copper and aluminum conductors can meet your requirements, the more economical solution will be a function of the metal and the cable component costs Insulation thickness • For cables with a radial moisture barrier, “Southwire Standard Wall” reduced insulation thicknesses within the stress limits in AEIC specification CS9 are recommended • Cables referred to by “Traditional Wall” insulation (850 mils) follow the traditional insulation wall practice referenced in ICEA standard S-108-720 appendix F as still specified by a number of customers and utilities • For applications requiring smaller cable diameters, specific designs are available upon request within the stress limits in AEIC specification CS9 Sheath material • Copper and aluminum corrugated sheaths offer the best mechanical and moisture protection for your HV cable, and copper will provide better short circuit performance and improved connectability • Composite laminate sheaths in both copper and aluminum that offer excellent protection against moisture ingress Jacket • Standard outer jacket: extruded LLDPE with a co-extruded outer semi-conductive polyethylene layer for jacket integrity testing • Halogen Free Fire Retardant (HFFR) compounds are available upon request for installations in cable trays and ventilated troughs 44 138 kV Power Cables Conductor material is a matter of both customer preference and required current carrying capacity 138 kV Power Cables 138 kV XLPE Copper Conductor Traditional Wall 850 mil XLPE Copper Corrugated Sheath Cable Construction • Reverse Concentric Stranded Copper, Compressed Conductor or Milliken • Super Smooth Conductor Shield • Super Clean XLPE Insulation • Traditional Wall - 850 mil XLPE • True Triple Extrusion and Dry Cured • Firmly Bonded Insulation Shield • Welded Copper Corrugated Sheath • Polyethylene Jacket with Extruded Semi-Conductive Outer Layer Cable Data Voltage Characteristics (kV) Max Voltage Rating 145 BIL Rating 650 Temperatures ( C) o Nominal Conductor 90 Max. Emergency Conductor 105 Short Circuit Conductor 250 Minimum Installation -10 Design Characteristics Design Standards Typical Test Voltages XLPE Loss Factor Relative Permittivity AEIC, IEC 240 kV / 15 min. 0.0005 2.3 45 Section 4 Conductor Size in kcmil1 750 1000 1250 1500 1750 2000 2500 3000 3500 4000 Nominal Conductor Diameter in 0.97 1.12 1.25 1.37 1.48 1.61 1.76 1.92 2.08 2.21 mm 24.7 28.5 31.8 34.8 37.6 40.9 44.7 48.8 52.8 56.1 in 2.79 2.94 3.07 3.19 3.30 3.40 3.66 3.82 3.98 4.11 mm 70.8 74.6 78.0 81.0 83.8 86.4 93.0 97.1 101.0 104.4 in 3.34 3.50 3.65 3.78 3.90 4.02 4.31 4.49 4.66 4.80 mm 84.8 89.0 92.7 96.0 99.1 102.0 109.4 113.9 118.3 122.0 in 3.62 3.78 3.93 4.06 4.18 4.30 4.59 4.77 4.94 5.08 mm 91.9 96.1 99.8 103.1 106.2 109.1 116.6 121.1 125.4 129.1 Diameter over Insulation Diameter over Sheath Overall Jacket Diameter Total Weight lbs/ft 6.8 7.9 8.9 9.9 10.9 11.9 14.1 16.0 18.0 19.8 Min. Bending Radius (install/ perm.) in 72/54 76/57 79/59 81/61 84/63 86/64 92/69 95/71 99/74 102/76 Maximum Pulling Tension lbs 6,000 8,000 10,000 12,000 14,000 16,000 20,000 24,000 28,000 32,000 138 kV Power Cables Dimensional Typical Shipping Reel Size in 138x95 150x95 150x95 150x95 150x95 158x95 158x95 158x95 158x95 158x95 Shipping Reel Capacity2 ft 3,000 3,000 3,000 2,725 2,750 2,775 2,550 2,250 1,925 1,825 Conductor Shield kV/mm 6.1 5.9 5.7 5.5 5.4 5.3 5.1 5.0 4.9 4.9 Insulation Shield kV/mm 2.4 2.5 2.5 2.6 2.6 2.7 2.7 2.8 2.8 2.9 Electrical Electrical Stress @ Uo Short Circuit for 0.5s3 Conductor kA 76.9 102.5 128.1 153.8 179.4 205.0 256.3 307.5 358.8 410.0 Sheath kA 41.8 43.9 45.7 47.4 48.9 50.3 54 56.2 58.3 60.2 DC @ 20o C Ω/kft 0.014 0.011 0.008 0.007 0.006 0.005 0.004 0.003 0.003 0.003 DC @ 90 C Ω/kft 0.018 0.014 0.011 0.009 0.008 0.007 0.005 0.005 0.004 0.003 Capacitance pF/ft 41.4 45.0 48.3 51.2 53.8 56.3 62.4 66.2 69.8 73.0 Charging Current Amps/ kft 1.24 1.35 1.45 1.54 1.62 1.69 1.87 1.99 2.10 2.19 Ampacity @ 90o C per circuit Typical Single Ductbank4 Amps 740 850 950 1030 1100 1170 1379 1515 1613 1698 Power Rating MVA 177 204 228 247 263 280 330 363 386 406 Typical Double Ductbank4 Amps 630 720 800 870 930 970 1153 1243 1316 1378 Power Rating MVA 151 173 192 208 223 232 276 298 315 330 Conductor Resistance o 2500-4000 kcmil conductors are 5 segment Milliken conductors. Increased shipping reel capacity can be accommodated on request. 3 Declared values for 30 mils copper sheath. Thicker sheath can accommodate more current. 4 4ft top of duct, 1oC-m/W native, 0.8oC-m/W ductbank backfill, 25oC Ambient, 75% lf, 9” spacing, single-point or cross bonded 1 2 46 Traditional Wall 850 mil XLPE Copper Corrugated Sheath Flange x Width 138 kV Power Cables 138 kV XLPE Copper Conductor SW Standard Wall XLPE Copper Corrugated Sheath Cable Construction • Reverse Concentric Stranded Copper, Compressed Conductor or Milliken • Super Smooth Conductor Shield • Super Clean XLPE Insulation • 630 mil XLPE minimum • True Triple Extrusion and Dry Cured • Firmly Bonded Insulation Shield • Welded Copper Corrugated Sheath • Polyethylene Jacket with Extruded Semi-Conductive Outer Layer Cable Data Voltage Characteristics (kV) Max Voltage Rating 145 BIL Rating 650 Temperatures ( C) o Nominal Conductor 90 Max. Emergency Conductor 105 Short Circuit Conductor 250 Minimum Installation -10 Design Characteristics Design Standards Typical Test Voltages XLPE Loss Factor Relative Permittivity AEIC, IEC 240 kV / 15 min. 0.0005 2.3 47 Section 4 Conductor Size in kcmil1 750 1000 1250 1500 1750 2000 2500 3000 3500 4000 Nominal Conductor Diameter in 0.97 1.12 1.25 1.37 1.48 1.61 1.76 1.92 2.08 2.21 mm 24.7 28.5 31.8 34.8 37.6 40.9 44.7 48.8 52.8 56.1 mils 770 730 700 680 660 650 630 630 630 640 mm 19.6 18.5 17.8 17.3 16.8 16.5 16.0 16.0 16.0 16.3 in 2.63 2.70 2.77 2.85 2.92 3.00 3.22 3.38 3.54 3.69 mm 66.8 68.5 70.4 72.4 74.2 76.3 81.8 85.9 89.8 93.7 in 3.16 3.23 3.30 3.39 3.46 3.56 3.81 3.98 4.15 4.32 mm 80.2 82.1 83.9 86.1 88.0 90.3 96.6 101.1 105.4 109.7 Overall Jacket Diameter in 3.44 3.51 3.58 3.67 3.74 3.84 4.09 4.26 4.43 4.60 mm 87.4 89.2 91.0 93.2 95.1 97.5 103.8 108.2 112.5 116.8 Total Weight lbs/ft 6.4 7.3 8.1 9.0 9.9 10.7 12.8 14.6 16.6 18.4 Min. Bending Radius (install/ perm.) in 69/52 70/53 72/54 73/55 75/56 77/58 82/61 85/64 89/66 92/69 Maximum Pulling Tension lbs 6,000 8,000 10,000 12,000 14,000 16,000 20,000 24,000 28,000 32,000 Insulation Thickness Diameter over Insulation Diameter over Sheath 138 kV Power Cables Dimensional Typical Shipping Reel Size in 126x95 126x95 126x95 126x95 126x95 150x95 150x95 150x95 150x95 150x95 Shipping Reel Capacity2 ft 3,000 3,000 3,000 3,000 2,950 3,000 2,725 2,500 2,225 2,000 Conductor Shield kV/mm 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.3 6.3 6.1 Insulation Shield kV/mm 2.7 3.0 3.2 3.4 3.6 3.7 3.9 4.0 4.0 4.0 Electrical Electrical Stress @ Uo Short Circuit for 0.5s3 Conductor kA 76.9 102.5 128.1 153.8 179.4 205.0 256.3 307.5 358.8 410.0 Sheath kA 39.6 40.5 41.4 42.5 43.4 44.6 47.7 49.9 52.0 54.1 DC @ 20o C Ω/kft 0.014 0.011 0.008 0.007 0.006 0.005 0.004 0.003 0.003 0.003 Conductor Resistance DC @ 90 C Ω/kft 0.018 0.014 0.011 0.009 0.008 0.007 0.005 0.005 0.004 0.003 Capacitance pF/ft 44.2 50.0 55.3 60.1 64.7 68.7 78.5 83.5 88.4 91.4 Charging Current Amps/ kft 1.33 1.50 1.66 1.80 1.95 2.06 2.36 2.51 2.65 2.75 Ampacity @ 90o C per circuit Typical Single Ductbank4 Amps 750 860 960 1050 1110 1180 1423 1546 1651 1746 Power Rating MVA 180 206 230 251 266 283 341 370 395 418 Typical Double Ductbank4 Amps 630 730 810 880 930 990 1172 1267 1345 1421 Power Rating MVA 151 175 194 211 223 237 281 303 322 340 o 1 2 2500-4000 kcmil conductors are 5 segment Milliken conductors. Increased shipping reel capacity can be accommodated on request. Declared values for 30 mils copper sheath. Thicker sheath can accommodate more current. 4ft top of duct, 1oC-m/W native, 0.8oC-m/W ductbank backfill, 25oC Ambient, 75% lf, 9” spacing, single-point or cross bonded 3 4 48 SW Standard Wall XLPE Copper Corrugated Sheath Flange x Traverse 138 kV Power Cables 138 kV XLPE Aluminum Conductor Traditional Wall 850 mil XLPE Aluminum Corrugated Sheath Cable Construction • Reverse Concentric Stranded Aluminum, Compressed Conductor • Super Smooth Conductor Shield • Super Clean XLPE Insulation • Traditional Wall – 850 mil XLPE • True Triple Extrusion and Dry Cured • Firmly Bonded Insulation Shield • Welded Aluminum Corrugated Sheath • Polyethylene Jacket with Extruded Semi-Conductive Outer Layer Cable Data Voltage Characteristics (kV) Max Voltage Rating 145 BIL Rating 650 Temperatures ( C) o Nominal Conductor 90 Max. Emergency Conductor 105 Short Circuit Conductor 250 Minimum Installation -10 Design Characteristics Design Standards Typical Test Voltages XLPE Loss Factor Relative Permittivity AEIC, IEC 240 kV / 15 min. 0.0005 2.3 49 Section 4 Conductor Size in kcmil Dimensional 750 1000 1250 1500 1750 2000 Nominal Conductor Diameter Diameter over Insulation Overall Jacket Diameter 0.97 1.12 1.25 1.38 1.49 1.61 24.7 28.5 31.8 35.0 37.8 40.9 in 2.79 2.94 3.07 3.19 3.30 3.40 mm 70.8 74.6 78.0 81.0 83.8 86.4 in 3.44 3.61 3.76 3.90 4.02 4.13 mm 87.4 91.7 95.5 98.9 102.1 105.0 in 3.72 3.89 4.04 4.18 4.30 4.41 mm 94.5 98.8 102.6 106.0 109.2 112.1 lbs/ft 4.5 5.0 5.5 5.9 6.3 6.7 Min. Bending Radius (install/perm.) in 74/56 78/58 81/61 84/63 86/64 88/66 Maximum Pulling Tension lbs 4,500 6,000 7,500 9,000 10,500 12,000 Flange x Traverse in 150x95 150x95 158x95 158x95 158x95 158x95 Shipping Reel Capacity1 ft 3,000 3,000 2,925 2,925 2,775 2,800 Conductor Shield kV/mm 6.1 5.9 5.7 5.5 5.4 5.3 Insulation Shield kV/mm 2.4 2.5 2.5 2.6 2.6 2.7 Conductor kA 50.8 67.7 84.6 101.5 118.5 135.4 Sheath kA 47.1 49.4 51.4 53.2 54.9 56.5 DC @ 20o C Ω/kft 0.023 0.017 0.014 0.012 0.010 0.009 DC @ 90o C Ω/kft 0.030 0.022 0.018 0.015 0.013 0.011 Capacitance pF/ft 41.4 45.0 48.3 51.2 53.8 56.3 Charging Current Amps/ kft 1.24 1.35 1.45 1.54 1.62 1.69 Total Weight 138 kV Power Cables Diameter over Sheath in mm Typical Shipping Reel Size Electrical Electrical Stress @ Uo Short Circuit for 0.5s 2 Ampacity @ 90o C Amps 580 680 760 840 900 960 Power Rating MVA 139 163 182 201 216 230 Typical Double Ductbank*** Amps 500 580 640 700 760 800 Power Rating MVA 120 139 153 168 182 192 Typical Single Ductbank 1 2 3 per circuit 3 Increased shipping reel capacity can be accommodated on request. Declared values for 50 mils aluminum sheath. Thicker sheath can accommodate more current. 4ft top of duct, 1oC-m/W native, 0.8oC-m/W ductbank backfill, 25oC Ambient, 75% lf, 9” spacing, single-point or cross bonded 50 Traditional Wall 850 mil XLPE Aluminum Corrugated Sheath Conductor Resistance 138 kV Power Cables 138 kV XLPE Aluminum Conductor SW Standard Wall XLPE Aluminum Corrugated Sheath Cable Construction • Reverse Concentric Stranded Aluminum, Compressed Conductor • Super Smooth Conductor Shield • Super Clean XLPE Insulation • 650 mil XLPE minimum • True Triple Extrusion and Dry Cured • Firmly Bonded Insulation Shield • Welded Aluminum Corrugated Sheath • Polyethylene Jacket with Extruded Semi-Conductive Outer Layer Cable Data Voltage Characteristics (kV) Max Voltage Rating 145 BIL Rating 650 Temperatures ( C) o Nominal Conductor 90 Max. Emergency Conductor 105 Short Circuit Conductor 250 Minimum Installation -10 Design Characteristics Design Standards Typical Test Voltages XLPE Loss Factor Relative Permittivity AEIC, IEC 240 kV / 15 min. 0.0005 2.3 51 Section 4 Conductor Size in kcmil Dimensional 750 1000 1250 1500 1750 2000 Nominal Conductor Diameter Insulation Thickness Diameter over Sheath 0.97 1.12 1.26 1.38 1.49 1.61 24.7 28.5 31.9 35.0 37.8 40.9 mils 770 730 700 680 660 650 mm 19.6 18.5 17.8 17.3 16.8 16.5 in 2.63 2.70 2.77 2.85 2.92 3.00 mm 66.8 68.5 70.4 72.4 74.2 76.3 in 3.26 3.34 3.41 3.50 3.57 3.67 mm 82.8 84.7 86.6 88.8 90.7 93.1 Overall Jacket Diameter in 3.54 3.62 3.69 3.78 3.85 3.95 mm 89.9 91.8 93.7 95.9 97.8 100.3 Total Weight lbs/ft 4.2 4.5 4.7 5.1 5.4 5.7 Min. Bending Radius (install/perm.) in 71/53 72/54 74/55 76/57 77/58 79/59 Maximum Pulling Tension lbs 4,500 6,000 7,500 9,000 10,500 12,000 in 126x95 126x95 126x95 126x95 150x95 150x95 ft 3,000 3,000 2,950 2,950 3,000 3,000 Conductor Shield kV/mm 6.5 6.5 6.5 6.5 6.5 6.5 Insulation Shield kV/mm 2.7 3.0 3.2 3.4 3.6 3.7 Conductor kA 50.8 67.7 84.6 101.5 118.5 135.4 Sheath kA 44.6 45.6 46.6 47.8 48.8 50.1 DC @ 20o C Ω/kft 0.023 0.017 0.014 0.012 0.010 0.009 138 kV Power Cables Diameter over Insulation in mm Typical Shipping Reel Size Flange x Traverse Shipping Reel Capacity 1 Electrical Electrical Stress @ Uo Short Circuit for 0.5s2 DC @ 90 C Ω/kft 0.030 0.022 0.018 0.015 0.013 0.011 Capacitance pF/ft 44.2 50.0 55.3 60.1 64.7 68.7 Charging Current Amps/ kft 1.33 1.50 1.66 1.80 1.95 2.06 590 690 770 850 920 980 o Ampacity @ 90o C Typical Single Ductbank per circuit 3 Amps Power Rating MVA 142 165 185 204 220 235 Typical Double Ductbank3 Amps 500 580 650 710 770 810 Power Rating MVA 120 139 156 170 185 194 Increased shipping reel capacity can be accommodated on request. Declared values for 50 mils aluminum sheath. Thicker sheath can accommodate more current. 3 4ft top of duct, 1oC-m/W native, 0.8oC-m/W ductbank backfill, 25oC Ambient, 75% lf, 9” spacing, single-point or cross bonded 1 2 52 SW Standard Wall XLPE Aluminum Corrugated Sheath Conductor Resistance 138 kV Power Cables 138 kV XLPE Copper Conductor Traditional Wall 850 mil XLPE Copper Neutrals, Copper Composite Laminate Sheath Cable Construction • Reverse Concentric Stranded Copper, Compressed Conductor or Milliken • Super Smooth Conductor Shield • Super Clean XLPE Insulation • Traditional Wall – 850 mil XLPE • True Triple Extrusion and Dry Cured • Firmly Bonded Insulation Shield • Copper Neutrals with Copper Composite Laminate Sheath • Polyethylene Jacket with Extruded Semi-Conductive Outer Layer Cable Data Voltage Characteristics (kV) Max Voltage Rating 145 BIL Rating 650 Temperatures ( C) o Nominal Conductor 90 Max. Emergency Conductor 105 Short Circuit Conductor 250 Minimum Installation -10 Design Characteristics Design Standards Typical Test Voltages XLPE Loss Factor Relative Permittivity AEIC, IEC 240 kV / 15 min. 0.0005 2.3 53 Section 4 Conductor Size in kcmil1 750 1000 1250 1500 1750 2000 2500 3000 3500 4000 Nominal Conductor Diameter in 0.97 1.12 1.25 1.37 1.48 1.61 1.76 1.92 2.08 2.21 mm 24.7 28.5 31.8 34.8 37.6 40.9 44.7 48.8 52.8 56.1 in 2.79 2.94 3.07 3.19 3.30 3.40 3.66 3.82 3.98 4.11 mm 70.8 74.6 78.0 81.0 83.8 86.4 93.0 97.1 101.0 104.4 in 3.17 3.32 3.46 3.58 3.69 3.79 4.07 4.23 4.39 4.52 mm 80.6 84.4 87.8 90.8 93.6 96.2 103.4 107.5 111.4 114.8 in 3.49 3.64 3.78 3.90 4.01 4.11 4.39 4.55 4.71 4.84 mm 88.7 92.5 95.9 98.9 101.7 104.3 111.5 115.6 119.5 123.0 Diameter over Insulation Diameter over Sheath Overall Jacket Diameter Total Weight lbs/ft 6.8 7.8 8.8 9.7 10.7 11.6 13.8 15.6 17.5 19.3 Min. Bending Radius (install/ perm.) in 70/52 73/55 76/57 78/58 80/60 82/62 88/66 91/68 94/71 97/73 Maximum Pulling Tension lbs 6,000 8,000 10,000 12,000 14,000 16,000 20,000 24,000 28,000 32,000 138 kV Power Cables Dimensional Typical Shipping Reel Size Flange x Width in 138x95 138x95 150x95 150x95 150x95 150x95 158x95 158x95 158x95 158x95 Shipping Reel Capacity2 ft 3,000 3,000 3,000 3,000 2,733 2,725 2,700 2,375 2,125 1,900 Conductor Shield kV/mm 6.1 5.9 5.7 5.5 5.4 5.3 5.1 5.0 4.9 4.9 Insulation Shield kV/mm 2.4 2.5 2.5 2.6 2.6 2.7 2.7 2.8 2.8 2.9 Electrical Short Circuit for 0.5s3 Conductor kA 76.9 102.5 128.1 153.8 179.4 205.0 256.3 307.5 358.8 410.0 Sheath kA 43.9 44.2 44.6 44.9 45.2 45.5 46.2 46.6 47.0 47.4 DC @ 20o C Ω/kft 0.014 0.011 0.008 0.007 0.006 0.005 0.004 0.003 0.003 0.003 DC @ 90 C Ω/kft 0.018 0.014 0.011 0.009 0.008 0.007 0.005 0.005 0.004 0.003 Capacitance pF/ft 41.4 45.0 48.3 51.2 53.8 56.3 62.4 66.2 69.8 73.0 Charging Current Amps/ kft 1.24 1.35 1.45 1.54 1.62 1.69 1.87 1.99 2.10 2.19 Ampacity @ 90o C per circuit Typical Single Ductbank4 Amps 750 870 970 1060 1140 1210 1455 1592 1714 1821 Power Rating MVA 180 208 232 254 273 290 348 381 410 436 Typical Double Ductbank4 Amps 640 740 820 890 950 1000 1206 1314 1410 1493 Power Rating MVA 153 177 196 213 228 240 289 315 338 357 Conductor Resistance o 2500-4000 kcmil conductors are 5 segment Milliken conductors. Increased shipping reel capacity can be accommodated on request. 3 Declared values for 80 x 14 AWG copper wire screen with 6 mil copper tape shield. Larger wires can accommodate more current. 4 4ft top of duct, 1oC-m/W native, 0.8oC-m/W ductbank backfill, 25oC Ambient, 75% lf, 9” spacing, single-point or cross bonded 1 2 54 Traditional Wall 850 mil XLPE Copper Neutrals, Copper Composite Laminate Sheath Electrical Stress @ Uo 138 kV Power Cables 138 kV XLPE Copper Conductor SW Standard Wall XLPE Copper Neutrals, Copper Composite Laminate Sheath Cable Construction • Reverse Concentric Stranded Copper, Compressed Conductor or Milliken • Super Smooth Conductor Shield • Super Clean XLPE Insulation • 630 mil XLPE minimum • True Triple Extrusion and Dry Cured • Firmly Bonded Insulation Shield • Copper Neutrals with Copper Composite Laminate Sheath • Polyethylene Jacket with Extruded Semi-Conductive Outer Layer Cable Data Voltage Characteristics (kV) Max Voltage Rating 145 BIL Rating 650 Temperatures ( C) o Nominal Conductor 90 Max. Emergency Conductor 105 Short Circuit Conductor 250 Minimum Installation -10 Design Characteristics Design Standards Typical Test Voltages XLPE Loss Factor Relative Permittivity AEIC, IEC 240 kV / 15 min. 0.0005 2.3 55 Section 4 Conductor Size in kcmil1 750 1000 1250 1500 1750 2000 2500 3000 3500 4000 Nominal Conductor Diameter in 0.97 1.12 1.25 1.37 1.48 1.61 1.76 1.92 2.08 2.21 mm 24.7 28.5 31.8 34.8 37.6 40.9 44.7 48.8 52.8 56.1 mils 770 730 700 680 660 650 630 630 630 640 mm 19.6 18.5 17.8 17.3 16.8 16.5 16.0 16.0 16.0 16.3 in 2.63 2.70 2.77 2.85 2.92 3.00 3.22 3.38 3.54 3.69 mm 66.8 68.5 70.4 72.4 74.2 76.3 81.8 85.9 89.8 93.7 in 3.01 3.08 3.16 3.24 3.31 3.39 3.63 3.79 3.95 4.10 mm 76.5 78.3 80.1 82.2 83.9 86.1 92.2 96.3 100.2 104.2 Overall Jacket Diameter in 3.33 3.40 3.48 3.56 3.63 3.71 3.95 4.11 4.27 4.42 mm 84.6 86.4 88.3 90.3 92.1 94.2 100.4 104.4 108.4 112.3 Total Weight lbs/ft 6.4 7.3 8.1 8.9 9.8 10.6 12.7 14.4 16.3 18.1 Min. Bending Radius (install/ perm.) in 67/50 68/51 70/52 71/53 73/54 74/56 79/59 82/62 85/64 88/66 Maximum Pulling Tension lbs 6,000 8,000 10,000 12,000 14,000 16,000 20,000 24,000 28,000 32,000 Insulation Thickness Diameter over Insulation Diameter over Sheath 158x95 Flange x Traverse in 126x95 138x95 138x95 138x95 138x95 138x95 150x95 150x95 Shipping Reel Capacity2 ft 3,000 3,000 3,000 3,000 3,000 2,775 3,000 2,625 2,325 2,050 Conductor Shield kV/mm 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.3 6.3 6.1 Insulation Shield kV/mm 2.7 3.0 3.2 3.4 3.6 3.7 3.9 4.0 4.0 4.0 150x95 Electrical Electrical Stress @ Uo Short Circuit for 0.5s 3 Conductor kA 76.9 102.5 128.1 153.8 179.4 205.0 256.3 307.5 358.8 410.0 Sheath kA 45.4 43.6 43.8 44.0 44.2 44.4 45.0 45.5 45.9 46.3 Conductor Resistance 1 2 DC @ 20o C Ω/kft 0.014 0.011 0.008 0.007 0.006 0.005 0.004 0.003 0.003 0.003 DC @ 90o C Ω/kft 0.018 0.014 0.011 0.009 0.008 0.007 0.005 0.005 0.004 0.003 Capacitance pF/ft 44.2 50.0 55.3 60.1 64.7 68.7 78.5 83.5 88.4 91.4 Charging Current Amps/ kft 1.33 1.50 1.66 1.80 1.95 2.06 2.36 2.51 2.65 2.75 Ampacity @ 90o C per circuit Typical Single Ductbank4 Amps 760 880 980 1070 1150 1220 1472 1610 1733 1840 Power Rating MVA 182 211 235 256 275 292 352 385 415 440 Typical Double Ductbank4 Amps 640 740 820 890 960 1010 1214 1323 1419 1502 Power Rating MVA 153 177 196 213 230 242 291 317 340 360 2500-4000 kcmil conductors are 5 segment Milliken conductors. Increased shipping reel capacity can be accommodated on request. 56 Declared values for 80 x 14 AWG copper wire screen with 6 mil copper tape shield. Larger wires can accommodate more current. 4ft top of duct, 1oC-m/W native, 0.8oC-m/W ductbank backfill, 25oC Ambient, 75% lf, 9” spacing, single-point or cross bonded 3 4 SW Standard Wall XLPE Copper Neutrals, Copper Composite Laminate Sheath Typical Shipping Reel Size 138 kV Power Cables Dimensional 138 kV Power Cables 138 kV XLPE Aluminum Conductor Traditional Wall 850 mil XLPE Copper Neutrals, Aluminum Composite Laminate Sheath Cable Construction • Reverse Concentric Stranded Aluminum, Compressed Conductor • Super Smooth Conductor Shield • Super Clean XLPE Insulation • Traditional Wall – 850 mil XLPE • True Triple Extrusion and Dry Cured • Firmly Bonded Insulation Shield • Copper Neutrals with Aluminum Composite Laminate Sheath • Polyethylene Jacket with Extruded Semi-Conductive Outer Layer Cable Data Voltage Characteristics (kV) Max Voltage Rating 145 BIL Rating 650 Temperatures ( C) o Nominal Conductor 90 Max. Emergency Conductor 105 Short Circuit Conductor 250 Minimum Installation -10 Design Characteristics Design Standards Typical Test Voltages XLPE Loss Factor Relative Permittivity AEIC, IEC 240 kV / 15 min. 0.0005 2.3 57 Section 4 Conductor Size in kcmil Dimensional 750 1000 1250 1500 1750 2000 Nominal Conductor Diameter Diameter over Insulation Overall Jacket Diameter 0.97 1.12 1.26 1.38 1.49 1.61 24.7 28.5 31.9 35.0 37.8 40.9 in 2.79 2.94 3.07 3.19 3.30 3.40 mm 70.8 74.6 78.0 81.0 83.8 86.4 in 3.18 3.33 3.46 3.58 3.69 3.79 mm 80.7 84.5 87.8 90.9 93.7 96.3 in 3.50 3.65 3.78 3.90 4.01 4.11 mm 88.8 92.6 96.0 99.0 101.8 104.4 lbs/ft 5.0 5.5 5.9 6.3 6.7 7.1 Min. Bending Radius (install/perm.) in 70/52 73/55 76/57 78/58 80/60 82/62 Maximum Pulling Tension lbs 4,500 6,000 7,500 9,000 10,500 12,000 Flange x Width in 138x95 138x95 150x95 150x95 150x95 150x95 Shipping Reel Capacity1 ft 3,000 3,000 3,000 3,000 2,725 2,725 Conductor Shield kV/mm 6.1 5.9 5.7 5.5 5.4 5.3 Insulation Shield kV/mm 2.4 2.5 2.5 2.6 2.6 2.7 Conductor kA 50.8 67.7 84.6 101.5 118.5 135.4 Sheath kA 42.9 43.2 43.5 43.8 44.1 44.3 DC @ 20o C Ω/kft 0.023 0.017 0.014 0.012 0.010 0.009 DC @ 90o C Ω/kft 0.030 0.022 0.018 0.015 0.013 0.011 Capacitance pF/ft 41.4 45.0 48.3 51.2 53.8 56.3 Charging Current Amps/ kft 1.24 1.35 1.45 1.54 1.62 1.69 Total Weight 138 kV Power Cables Diameter over Sheath in mm Typical Shipping Reel Size Electrical Electrical Stress @ Uo Short Circuit for 0.5s 2 Ampacity @ 90o C per circuit Amps 590 690 780 860 930 990 Power Rating MVA 142 165 187 206 223 237 Typical Double Ductbank3 Amps 500 580 650 720 770 830 Power Rating MVA 120 139 156 173 185 199 Typical Single Ductbank 3 Increased shipping reel capacity can be accommodated on request. Declared values for 80 x 14 AWG copper wire screen with 8 mil aluminum tape shield. Larger wires can accommodate more current. 4ft top of duct, 1oC-m/W native, 0.8oC-m/W ductbank backfill, 25oC Ambient, 75% lf, 9” spacing, single-point or cross bonded 1 2 3 58 Traditional Wall 850 mil XLPE Copper Neutrals, Aluminum Composite Laminate Sheath Conductor Resistance 138 kV Power Cables 138 kV XLPE Aluminum Conductor SW Standard Wall XLPE Copper Neutral, Aluminum Composite Laminate Sheath Cable Construction • Reverse Concentric Stranded Aluminum, Compressed Conductor • Super Smooth Conductor Shield • Super Clean XLPE Insulation • 650 mil XLPE minimum • True Triple Extrusion and Dry Cured • Firmly Bonded Insulation Shield • Copper Neutrals with Aluminum Composite Laminate Sheath • Polyethylene Jacket with Extruded Semi-Conductive Outer Layer Cable Data Voltage Characteristics (kV) Max Voltage Rating 145 BIL Rating 650 Temperatures ( C) o Nominal Conductor 90 Max. Emergency Conductor 105 Short Circuit Conductor 250 Minimum Installation -10 Design Characteristics Design Standards Typical Test Voltages XLPE Loss Factor Relative Permittivity AEIC, IEC 240 kV / 15 min. 0.0005 2.3 59 Section 4 Conductor Size in kcmil Dimensional 750 1000 1250 1500 1750 2000 Nominal Conductor Diameter Insulation Thickness Diameter over Sheath 0.97 1.12 1.26 1.38 1.49 1.61 24.7 28.5 31.9 35.0 37.8 40.9 mils 770 730 700 680 660 650 mm 19.6 18.5 17.8 17.3 16.8 16.5 in 2.63 2.70 2.77 2.85 2.92 3.00 mm 66.8 68.5 70.4 72.4 74.2 76.3 in 3.02 3.09 3.16 3.24 3.31 3.39 mm 76.6 78.4 80.2 82.2 84.0 86.2 Overall Jacket Diameter in 3.34 3.41 3.48 3.56 3.63 3.71 mm 84.8 86.5 88.4 90.3 92.2 94.3 Total Weight lbs/ft 4.7 5.0 5.3 5.6 5.9 6.2 Min. Bending Radius (install/perm.) in 67/50 68/51 70/52 71/53 73/54 74/56 Maximum Pulling Tension lbs 4,500 6,000 7,500 9,000 10,500 12,000 in 126x95 138x95 138x95 138x95 138x95 138x95 ft 3,000 3,000 3,000 3,000 3,000 2,775 Conductor Shield kV/mm 6.5 6.5 6.5 6.5 6.5 6.5 Insulation Shield kV/mm 2.7 3.0 3.2 3.4 3.6 3.7 Conductor kA 50.8 67.7 84.6 101.5 118.5 135.4 Sheath kA 42.5 42.7 42.8 43.0 43.2 43.4 DC @ 20o C Ω/kft 0.023 0.017 0.014 0.012 0.010 0.009 138 kV Power Cables Diameter over Insulation in mm Typical Shipping Reel Size Flange x Traverse Shipping Reel Capacity 1 Electrical Electrical Stress @ Uo Short Circuit for 0.5s2 DC @ 90 C Ω/kft 0.028 0.021 0.017 0.014 0.012 0.011 Capacitance pF/ft 44.2 50.0 55.3 60.1 64.7 68.7 Charging Current Amps/ kft 1.33 1.50 1.66 1.80 1.95 2.06 600 700 790 870 940 1000 o Ampacity @ 90o C Typical Single Ductbank per circuit 3 Amps Power Rating MVA 144 168 189 208 225 240 Typical Double Ductbank3 Amps 500 590 660 720 780 830 Power Rating MVA 120 142 158 173 187 199 Increased shipping reel capacity can be accommodated on request. Declared values for 80 x 14 AWG copper wire screen with 8 mil aluminum tape shield. Larger wires can accommodate more current. 3 4ft top of duct, 1oC-m/W native, 0.8oC-m/W ductbank backfill, 25oC Ambient, 75% lf, 9” spacing, single-point or cross bonded 1 2 60 SW Standard Wall XLPE Copper Neutral, Aluminum Composite Laminate Sheath Conductor Resistance