Preview only show first 10 pages with watermark. For full document please download

Spd243001

   EMBED


Share

Transcript

Switching Power Supply Type SPD 300W DIN rail mounting • Installation on DIN Rail 7.5 or 15mm • Short circuit protection • Passive PFC • Power ready relay output on 24VDC • LED indicator for DC power ON • LED indicator for DC low • Parallel function by switch • Very compact dimensions • UL, cUL listed and TUV/CE approved • Class I division 2 certification • Selv design Product Description This SPD is the most compact 300W power supply on the market. Relay output for “power ready” parallel function and PFC are included. Performances are unique with high Ordering Key efficiencies and the possibility of being used up to 70°C with a little derating. Thanks to the Class I Div 2 design is suitable for installation in potentially explosive environments. au art geprü 1= single phase Nil= screw terminals B= Detachable connectors f t B Model Mounting ( D = Din rail ) Output voltage Output power Input type Connection Input type: Connection: Approvals SP D 24 300 1 B p e T d Rheinland Product Safety y e appro v Output Performances Rated output Output Voltage Power (VDC) (W) 24 300 SPD24300 48 300 SPD48300 Model DC ON LED (VDC) DC LO LED (VDC) Output Voltage Trim Range Typical Threshold at startup Threshold after startup Current (A) Efficiency Min. VDC Max. VDC Min. Max. Min. Max. 12.5 22.5 28.5 17.6 19.4 17.6 19.4 89% 6.25 47.0 56.0 37.0 43.0 37.0 43.0 90% Output Data Output voltage accuracy Line regulation Load regulation Non parallel model Parallel model Ripple and noise Vi nom, Io nom, BW=20MHz Rated continuous Loading Fall Time Transient recovery time Vi nom, Io= 0.5 x Inom 1 -0 +1% max (factory adjusted) ± 0.5% ± 1% ± 5% 100mV 12.5A @ 10.5A @ 6.25A @ 5.35A @ 150ms 2ms 24VDC / 28.5VDC 48VDC / 56VDC Turn On Time Vi nom, Io nom Vi nom, Io nom with Capacitor load Rise Time Vi nom, Io nom Vi nom, Io nom with Capacitor load Capacitor Load Reverse Voltage Immunity 24V 48V Hold up Time Vi = 115VAC Io nom Hold up Time Vi = 230VAC Io nom Minimum load Vi nom Parallel Operation 0.1 Io min~0.9 Io max 1.0s 1.5s 150ms 500ms 7000µF 35V 63V 25ms 30ms 0% 3 units max. Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. - 0940 Switching Power Supply Type SPD 300W DIN rail mounting Input Data Rated AC input voltage Voltage range AC (autoselect) 115V 230V DC in Rated input current 115/230V Typ. Max. Power dissipation 24V 48V 115 / 230VAC Frequency range 47 - 63Hz Internal Voltage Surge Protection Varistor 90 - 132VAC 180 - 264VAC 210 - 375VDC (acc. to IEC61000-4-5) 4.8 / 1.9A 6.0 / 3.0A 42W 40W Leakage Current Input / Output Input / FG Inrush current Vi= 115VAC Vi= 230VAC P.F.C. (passive) 35A 65A 0.75 Power ready (only SPD243001) Threshold at start up Min. 17.6VDC - Max.19.4VDC 0.25mA 3.5mA Controls and Protections Input Fuse Output Short Circuit Rated Overload Protection Over voltage protection Input Voltage Surge Protection 1) T8/250VAC internal1) fold forward 120 - 145% 125 - 140% Varistor (contact closed) Contact rating at 60VDC Insulation 0.3A 500VDC Fuse not replaceable by user General Data (@ nominal line, full load, 25°C ) Ambient temperature Derating (>+56°C to +71°C) Ambient humidity Storage Pollution degree Protection degree Cooling Switching frequency -25°C to 71°C 2.5% / °C 20 to 95%RH -25°C to +85°C 2 IP20 Free air convection 40kHz MTBF (Bellcore Issue 6@40°C), GB 24V model 48V model Altitude during operation Case material Dimensions L x W x D Screw terminals Detachable connections Weight 415.000h 431.000h 2.000m Metal 124.5 x 83.5 x 123.6mm 143.5 x 83.5 x 123.6mm 400g Approvals and EMC Insulation voltage Input / Output Input / FG Insulation resistance Shock resistance 3.000VAC / 4242VDC 1500VAC / 2121VDC 100MΩ min acc. to IEC 60068-2-27 Vibration resistance acc. to IEC 60068-2-6 CE (15G, 11ms, 3 Axis, 6 Faces, 3 times for each Face) (Mounting by rail: 10-500 Hz, 2G, along X, Y, Z each Axis, 60 min for each Axis) UL / cUL TUV UL 508 Listed UL 60950-1, Recognized ISA 12.12.01 (Class I, Division 2, Groups A, B, C and D) EN 60950-1, CB scheme EN 61558-1, EN 61558-2-17 (acc.to EN 60204) EN 61000-6-3, EN 55022 Class B, EN 61000-3-2 Class D, EN 61000-3-3 EN 61000-6-2, EN 55024, EN 61000-4-2 Level 4, EN 61000-4-3 Level 3 EN 61000-4-4 Level 4, EN 61000-4-5 L-N Level 3, L / N-FG Level 4 EN 61000-4-6 Level 3, EN 61000-4-8 Level 4, EN 61000-4-11 ENV 50204 Level 2, EN 61204-3 0940 - Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 2 Switching Power Supply Type SPD 300W DIN rail mounting Block Diagrams L Fuse Filter N Inrush Current Limiter, Rectifier and Auto Select 115 / 230 Vac Vo + P. F. C. Circuit Y Smoothing Circuit Switching Device PWM Controller Rectifier Current Detection Vo Single / Parallel Select Opto Isolation Reference & Error Amp. Opto Isolation Over Voltage Detection Vout ADJ. Output Level Detection DC ON ( Green LED) DC LOW ( Red LED) RDY 1) ( Relay Contact) 1) only SPD243001 Pin Assignment and Front Controls Pin No. Designation Description 1 2 3 4 5 6 7 8 9 RDY RDY V+ V+ VVGND N L NO relay contact for DC OK (only SPD243001) NO relay contact for DC OK (only SPD243001) Positive output terminal Positive output terminal Negative output terminal Negative output terminal Ground terminal to minimise High frequency emissions Neutral input (no polarity with DC input) Phase input (no polarity with DC input) L1 L2 POT1 SW1 DC ON DC LO Vout ADJ. S/P DC output ready LED DC low indicator LED Trimmer for fine output voltage adjustment Single / Parallel select switch Output Voltage (%) Typ. Current Limited Curve 100 75 230Vac 115Vac 50 25 0 100 110 Referred to SPD243001 3 120 130 140 Power Out (%) 150 160 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. - 0940 Switching Power Supply Type SPD 300W DIN rail mounting Typ. Efficiency Curve Derating Diagram Efficiency (%) Power out (%) 89 88 87 86 85 84 83 82 81 80 100 90 80 70 60 50 40 30 20 10 0 230Vac 115Vac 10 50 Power Out (%) 25 75 100 -25/ -13 -20/ -4 -15/ -5 -10/ 14 +50/ +55/ +60/ +65/ +70/ +75/ 122 131 140 149 158 167 Temperature °C / °F Mechanical Drawings mm (inches) 83.5 [3.29] 1 - -+ + Vout A D J. L2 Rdy Vout A D J. 124.5 [4.9] DC LO DC O N - -+ + S P Rdy DC LO DC O N 124.5 [4.9] S P 7.0 [0.3] 1 143.5 [5.65] POT1 6 116.6 [4.59] 83.5 [3.29] 6 SW1 +71/ 159.8 L1 L N L N AC INPUT 7 9 7 9 Installation Ventilation and cooling Screw terminals Max. torque for screws terminals Input terminals Output terminals Max. torque for detachable connections Input terminals Output terminals Plug-in connectors Normal convection All sides 25mm free space for cooling is recommended 10-24AWG flexible or solid cable 8mm stripping recommend 1.008Nm (9.0lb-in) 0.616Nm (5.5lb-in) 1.008Nm (9.0lb-in) 0.616Nm (5.5lb-in) 10-24AWG flexible or solid cable 7mm stripping recommend Max. torque for plug-in terminals Input terminals 0.784Nm (7.0lb-in) Output terminals 0.784Nm (7.0lb-in) Recommended circuit breaker 15A / 16A B, D characteristics 0940 - Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 4