Preview only show first 10 pages with watermark. For full document please download

Spec. Fec40

   EMBED


Share

Transcript

FEC40 FEC40 SERIES DC-DC CONVERTER 2:1 WIDE INPUT RANGE UP TO 40Watts FEATURES APPLICATIONS • 1600VDC INPUT TO OUTPUT ISOLATION • STANDARD 2.00 X 2.00 X 0.40 INCH • SIX-SIDED CONTINUOUS SHIELD • UL60950-1, EN60950-1, & IEC60950-1 SAFETY APPROVALS • CE MARKED • COMPLIANT TO RoHS II & REACH 1600VDC ISOLATION REMOTE CONTROL UVP OCP • WIRELESS NETWORK • TELECOM/DATACOM • INDUSTRY CONTROL SYSTEM • DISTRIBUTED POWER ARCHITECTURES • SEMICONDUCTOR EQUIPMENT SCP OVP OTP TECHNICAL SPECIFICATION All specifications are typical at nominal input, full load and 25 Model Number FEC40-12S1P5 FEC40-12S1P8 FEC40-12S2P5 FEC40-12S3P3 FEC40-12S05 FEC40-12S12 FEC40-12S15 FEC40-12D12 FEC40-12D15 FEC40-12D3305 FEC40-12T3312 FEC40-12T3315 FEC40-12T0512 FEC40-12T0515 FEC40-24S1P5 FEC40-24S1P8 FEC40-24S2P5 FEC40-24S3P3 FEC40-24S05 FEC40-24S12 FEC40-24S15 FEC40-24D12 FEC40-24D15 FEC40-24D3305 FEC40-24T3312 FEC40-24T3315 FEC40-24T0512 FEC40-24T0515 FEC40-48S1P5 FEC40-48S1P8 FEC40-48S2P5 FEC40-48S3P3 FEC40-48S05 FEC40-48S12 FEC40-48S15 FEC40-48D12 FEC40-48D15 FEC40-48D3305 FEC40-48T3312 FEC40-48T3315 FEC40-48T0512 FEC40-48T0515 Input Range Output Voltage VDC VDC 9 ~ 18 9 ~ 18 9 ~ 18 9 ~ 18 9 ~ 18 9 ~ 18 9 ~ 18 9 ~ 18 9 ~ 18 9 ~ 18 9 ~ 18 9 ~ 18 9 ~ 18 9 ~ 18 18 ~ 36 18 ~ 36 18 ~ 36 18 ~ 36 18 ~ 36 18 ~ 36 18 ~ 36 18 ~ 36 18 ~ 36 18 ~ 36 18 ~ 36 18 ~ 36 18 ~ 36 18 ~ 36 36 ~ 75 36 ~ 75 36 ~ 75 36 ~ 75 36 ~ 75 36 ~ 75 36 ~ 75 36 ~ 75 36 ~ 75 36 ~ 75 36 ~ 75 36 ~ 75 36 ~ 75 36 ~ 75 1.5 1.8 2.5 3.3 5 12 15 ±12 ±15 3.3 / 5 3.3 / ±12 3.3 / ±15 5 / ±12 5 / ±15 1.5 1.8 2.5 3.3 5 12 15 ±12 ±15 3.3 / 5 3.3 / ±12 3.3 / ±15 5 / ±12 5 / ±15 1.5 1.8 2.5 3.3 5 12 15 ± 12 ± 15 3.3 / 5 3.3 / ±12 3.3 / ±15 5 / ±12 5 / ±15 Output Current @Full Load Min. Load (1) mA 0 0 0 0 0 0 0 ±144 ±112 0 600 / ±40 600 / ±30 600 / ±40 600 / ±30 0 0 0 0 0 0 0 ±144 ±112 0 600 / ±40 600 / ±30 600 / ±40 600 / ±30 0 0 0 0 0 0 0 ±144 ±112 0 600 / ±40 600 / ±30 600 / ±40 600 / ±30 otherwise noted Input Current @ No Load Efficiency Maximum Capacitor Load (2) mA % µF 110 110 110 175 225 255 310 30 35 325 215 230 280 255 40 40 40 60 80 70 85 20 20 80 65 65 60 75 25 25 25 35 40 50 50 15 15 45 35 35 30 40 84 82 84 86 86 86 87 85 85 85 84 84 86 86 81 83 86 87 89 88 89 87 87 86 85 85 87 87 82 84 86 88 90 89 89 87 87 88 86 86 88 88 Full Load mA 8000 8000 8000 8000 8000 3333 2666 ±1800 ±1400 4000 / 4000(3) 6000 / ±400 6000 / ±300 6000 / ±400 6000 / ±300 8000 8000 8000 8000 8000 3333 2666 ±1800 ±1400 4000 / 4000(3) 6000 / ±400 6000 / ±300 6000 / ±400 6000 / ±300 8000 8000 8000 8000 8000 3333 2666 ±1800 ±1400 4000 / 4000(3) 6000 / ±400 6000 / ±300 6000 / ±400 6000 / ±300 45000 37700 27000 21000 13600 2360 1510 ±1200 ±750 11000 / 6800 13000 / ±330 13000 / ±110 6800 / ±330 6800 / ±110 45000 37700 27000 21000 13600 2360 1510 ±1200 ±750 11000 / 6800 13000 / ±330 13000 / ±110 6800 / ±330 6800 / ±110 45000 37700 27000 21000 13600 2360 1510 ±1200 ±750 11000 / 6800 13000 / ±330 13000 / ±110 6800 / ±330 6800 / ±110 Advice Electronics Ltd Advice Building,16 Atir Yeda St., Kfar Saba, 4464321, Israel Tel:+972-3-9000910 [email protected] www.advice.co.il FEC40 PART NUMBER STRUCTURE FEC40 - 48 Series Name S Input Voltage (VDC) 12: 9~18 24: 18~36 48: 36~75 Output Quantity S: Single D: Dual Dual Positive T: Triple 05 INPUT SPECIFICATIONS Parameter Start up time Constant resistive load Input surge voltage 100 ms, max. Input filter Remote ON/OFF Referred to –Vin pin OUTPUT SPECIFICATIONS Parameter Typ. Max. Unit 9 18 36 12 24 48 40 18 36 75 VDC 12Vin(nom) 24Vin(nom) 48Vin(nom) 12Vin(nom) 24Vin(nom) 48Vin(nom) Power up Remote ON/OFF 12Vin(nom) 24Vin(nom) 48Vin(nom) 8 16 34 25 25 DC-DC ON DC-DC OFF Input current of Ctrl pin Remote off input current Conditions Low Line to High Line at Full Load Single / Dual: Min. Load to Full Load mAp-p 9 17.8 36 Positive logic Voltage accuracy Voltage adjustability (4) Ripple and noise Min. Nominal input and Full load Shutdown voltage Cross regulation : None HS: Heat-sink HC: Heat-sink with Clamp 12Vin(nom) 24Vin(nom) 48Vin(nom) Input reflected ripple current Start-up voltage Load regulation Assembly Option Conditions Operating input voltage range Line regulation HS - Output Voltage (VDC) 1P5: 1.5 1P8: 1.8 2P5: 2.5 3P3: 3.3 05: 5 12: 12 15: 15 12: ±12 15: ±15 3305: 3.3 / 5 3312: 3.3 / ±12 3315: 3.3 / ±15 0512: 5 / ±12 0515: 5 / ±15 -0.5 Min. Single / Dual Triple: 3.3Vout, 5Vout Triple: 12Vout, 15Vout Single / Dual Triple: 3.3Vout, 5Vout Triple: 12Vout, 15Vout Single Dual Triple: 3.3Vout, 5Vout Triple: 12Vout, 15Vout Triple: Main output: :(3.3Vout, 5Vout) 10% to 100% with 10% to 100% balanced on auxiliaries. Auxiliary outputs 10% to 100% balanced on all outputs. Dual: Asymmetrical load 25%/100% FL Dual Triple: Main output:(3.3Vout, 5Vout) 100% load, Triple: 3.3Vout, 5Vout auxiliary 100%, other auxiliary 25% to 100% Triple: 12Vout, 15Vout load or main output:(3.3Vout, 5Vout) 25%, auxiliary 25%, other auxiliary 25% to 100%. Single and Dual output (not including Dual Positive and triple) Measured by 20MHz bandwidth With a 0.1µF/50V MLCC Single Others 12Vout, 15Vout Dual 12Vout 15Vout Triple 3.3Vout, 5Vout 12Vout, 15Vout With a 1µF ceramic output capacitors Dual Positive 3.3Vout, 5Vout VDC VDC ms 36 50 VDC 100 L-C type Open or 3.5 ~ 12VDC Short or 0 ~ 1.2VDC +0.5 mA 2.5 mA Typ. Max. Unit -1.0 -1.0 -5.0 -0.5 -1.0 -5.0 -0.5 -1.0 -2.0 -5.0 +1.0 +1.0 +5.0 +0.5 +1.0 +5.0 +0.5 +1.0 +2.0 +5.0 -5.0 -1.0 -5.0 +5.0 +1.0 +5.0 % -10 +10 % 50 75 120 150 50 75 100 % % % mVp-p Advice Electronics Ltd Advice Building,16 Atir Yeda St., Kfar Saba, 4464321, Israel Tel:+972-3-9000910 [email protected] www.advice.co.il FEC40 OUTPUT SPECIFICATIONS Parameter Temperature coefficient Transient response recovery time Over voltage protection Over load protection Short circuit protection Conditions Min. Typ. -0.02 25% load step change Zener diode clamp 1.5Vout 1.8Vout 2.5Vout 3.3Vout 5Vout 12Vout 15Vout % of Iout rated Conditions 1 minute Isolation resistance Isolation capacitance Switching frequency 500VDC Min. Input to Output Input(Output) to Case Others Dual Positive µs 3.9 3.9 3.9 3.9 6.2 15 18 VDC Typ. Max. 1600 1600 1 5Vout 3.3Vout 270 270 450 1000 330 330 550 300 300 500 GΩ pF kHz UL60950-1 EN60950-1 IEC60950-1 Nickel-coated copper FR4 PCB Epoxy (UL94 V-0) 60g (2.11oz) 9.224 x 105 hrs Conditions Min. With derating Typ. -40 Max. Unit +85 +100 +115 -55 Vertical direction by natural convection (20LFM) Without heat-sink With heat-sink With heat-sink (500LFM) +125 9.2 7.6 2.8 /W Thermal shock Vibration Relative humidity MIL-STD-810F MIL-STD-810F 5% to 95% RH EMC SPECIFICATIONS Parameter EMI (5) ESD Radiated immunity Fast transient (6) Surge (6) Conducted immunity Power frequency magnetic field Unit VDC MIL-HDBK-217F, Full load ENVIRONMENTAL SPECIFICATIONS Parameter Operating ambient temperature Maximum case temperature Over temperature protection Storage temperature range Thermal impedance %/ 250 Safety approvals Case material Base material Potting material Weight MTBF Unit +0.02 150 % Continuous, automatics recovery GENERAL SPECIFICATIONS Parameter Isolation voltage Max. Conditions EN55022 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 Level Air ± 8kV and Contact ± 6kV 10 V/m ± 2kV ± 1kV 10 Vr.m.s 100A/m continuous; 1000A/m 1 second Class A, Class B Perf. Criteria B Perf. Criteria A Perf. Criteria B Perf. Criteria B Perf. Criteria A Perf. Criteria A Note: 1. 2. 3. 4. 5. 6. The output requires a minimum loading on the output to maintain specified regulation. Operation under no-load condition will not damage these devices, however they may not meet all listed specification. Test by minimum input and constant resistive load. Any condition of dual output (3.3Vout, 5Vout) rated Iout current, not to exceed 8A of total output currents. The product safety approval pending. For the single output: Maximum output deviation is 10% inclusive of remote sense and trim. If remote sense is not being used, the +Sense should be connected to its corresponding +Vout and likewise the -Sense should be connected to its corresponding -Vout. The standard module meet EN55022 Class A and Class B with external components. For further information, please contact with P-DUKE. An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5. The filter capacitor Power Mate suggest: Nippon chemi-con KY series, 220µF/100V. CAUTION: This power module is not internally fused. An input line fuse must always be used. Advice Electronics Ltd Advice Building,16 Atir Yeda St., Kfar Saba, 4464321, Israel Tel:+972-3-9000910 [email protected] www.advice.co.il FEC40 CHARACTERISTIC CURVE FEC40-48S05 Derating Curve FEC40-48S05 Derating Curve With Heat-sink FEC40-48S05 Efficiency vs. Input Voltage FEC40-48S05 Efficiency vs. Output Load MECHANICAL DRAWING PIN CONNECTION PIN SINGLE DUAL POSITIVE +Vin -Vin Ctrl 3.3Vout Common NC NC 5Vout Common DUAL 1 +Vin 2 -Vin 3 Ctrl 4 NC 5 -Sense (4) 6 +Sense (4) 7 +Vout 8 -Vout 9 Trim * NC : No Connection +Vin -Vin Ctrl No pin +Vout Common Common -Vout Trim TRIPLE +Vin -Vin Ctrl +Aux Common -Aux +Vout Common NC EXTERNAL OUTPUT TRIMMING Output can be externally trimmed by using the method shown below. ( ) for dual output trim. TRIM UP 5(8) TRIM DOWN 9(9) RU 9(9) RD 6(5) 1. All dimensions in inch (mm) 2. Tolerance :x.xx±0.02 (x.x±0.5) x.xxx±0.01 (x.xx±0.25) 3. Pin pitch tolerance ±0.01 (0.25) 4. Pin dimension tolerance ±0.004(0.1) Advice Electronics Ltd Advice Building,16 Atir Yeda St., Kfar Saba, 4464321, Israel Tel:+972-3-9000910 [email protected] www.advice.co.il