Transcript
FED40W
FED40W SERIES DC-DC CONVERTER 4:1 WIDE INPUT RANGE UP TO 40Watts
FEATURES
APPLICATIONS
• NO MINIMUM LOAD REQUIRED • 1600VDC INPUT TO OUTPUT ISOLATION FOR 24VIN AND 48VIN 3000VDC INPUT TO OUTPUT ISOLATION FOR 110VIN • STANDARD 2.00 X 1.00 X 0.40 INCH • SIX-SIDED CONTINUOUS SHIELD • SAFETY MEETS UL60950-1, EN60950-1, & IEC60950-1 • COMPLIANCE TO EN50155 AND EN45545-2 RAILWAY STANDARD • CE MARKED • COMPLIANT TO RoHS II & REACH
3000VDC ISOLATION
1600VDC ISOLATION
REMOTE CONTROL
UVP
• RAILWAY SYSTEM • WIRELESS NETWORK • TELECOM/DATACOM • INDUSTRY CONTROL SYSTEM • DISTRIBUTED POWER ARCHITECTURES • SEMICONDUCTOR EQUIPMENT
OCP
SCP
OTP
OVP
LOW STANDBY POWER
TECHNICAL SPECIFICATION All specifications are typical at nominal input, full load and 25℃ otherwise noted Model Number FED40-24S3P3W FED40-24S05W FED40-24S12W FED40-24S15W FED40-24S24W FED40-24D12W FED40-24D15W FED40-24D24W FED40-48S3P3W FED40-48S05W FED40-48S12W FED40-48S15W FED40-48S24W FED40-48D12W FED40-48D15W FED40-48D24W FED40-110S3P3W FED40-110S05W FED40-110S12W FED40-110S15W FED40-110S24W FED40-110D12W FED40-110D15W FED40-110D24W
Input Range
Output Voltage
Output Current @Full Load
Input Current @ No Load
Efficiency
Maximum Capacitor Load (1)
VDC 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 43 ~ 160 43 ~ 160 43 ~ 160 43 ~ 160 43 ~ 160 43 ~ 160 43 ~ 160 43 ~ 160
VDC 3.3 5 12 15 24 ±12 ±15 ±24 3.3 5 12 15 24 ±12 ±15 ±24 3.3 5 12 15 24 ±12 ±15 ±24
mA 10000 8000 3333 2666 1666 ±1666 ±1333 ±833 10000 8000 3333 2666 1666 ±1666 ±1333 ±833 10000 8000 3333 2666 1666 ±1666 ±1333 ±833
mA 15 15 15 15 15 15 15 15 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10
% 90 91 92 92 91 90 90 91 90 91 92 92 91 90 90 91 88 89 90.5 91 90 89 89 91
µF 26600 20000 3900 2600 1300 ± 2600 ± 1600 ±650 26600 20000 3900 2600 1300 ± 2600 ± 1600 ±650 26600 20000 3900 2600 1300 ± 2600 ± 1600 ±650
PART NUMBER STRUCTURE
FED40 Series Name
48 Input Voltage (VDC) 24: 9~36 48: 18~75 110: 43~160
S Output Quantity S: Single
D: Dual
05 Output Voltage (VDC) 3P3: 3.3 05: 5 12: 12 15: 15 24: 24 12: ±12 15: ±15 24: ±24
W Input Range 4:1
N
HS
Remote Control Option
Assembly Option
: Positive logic N: Negative logic
: None HS Heat-sink HC Heat-sink with Clamp
Advice Electronics Ltd Advice Building,16 Atir Yeda St., Kfar Saba, 4464321, Israel Tel:+972-3-9000910
[email protected]
www.advice.co.il
FED40W INPUT SPECIFICATIONS Parameter
Conditions
Operating input voltage range
24Vin(nom) 48Vin(nom) 110Vin(nom) 24Vin(nom) 48Vin(nom) 110Vin(nom) 24Vin(nom) 48Vin(nom) 110Vin(nom) Power up Remote ON/OFF 24Vin(nom) 48Vin(nom) 110Vin(nom)
Start-up voltage
Shutdown voltage
Start up time
Constant resistive load
Input surge voltage
1 second, max.
Input filter Remote ON/OFF
Referred to –Vin pin
Conditions
Voltage accuracy Line regulation Load regulation
Low Line to High Line at Full Load No Load to Full Load
Cross regulation Voltage adjustability
Asymmetrical load 25%/100% FL Single output
Ripple and noise
Measured by 20MHz bandwidth With a 0.1µF/50V X7R MLCC
Temperature coefficient Transient response recovery time Over voltage protection
Over load protection Short circuit protection
Case material Base material Potting material Weight MTBF
36 75 160 9 18 43
-0.5
Typ.
-1.0 -0.2 -0.5 -1.0 -5.0 -10 -10
Single Dual Dual 3.3Vout, 5Vout, 12Vout 15Vout, 24Vout 3.3Vout, 5Vout 12Vout, 15Vout 24Vout
75 100 150
Conditions 110Vin(nom)
Min. Input to Output Input (Output) to Case Input to Output Input (Output) to Case
500VDC
VDC
VDC
VDC ms
Max.
Unit
+1.0 +0.2 +0.5 +1.0 +5.0 +10 +20 100 125 200 +0.02
% % % % % mVp-p
%/℃ 250 µs 3.9 6.2 15 VDC 20 30 150 % Continuous, automatics recovery
% of Iout rated; Hiccup mode
1 minute
Unit
50 100 VDC 170 Pi type Open or 3 ~ 12VDC Short or 0 ~ 1.2VDC Short or 0 ~ 1.2VDC Open or 3 ~ 12VDC 0.5 mA 3 mA
Min.
3.3Vout 5Vout 12Vout 15Vout 24Vout
Others Isolation resistance Isolation capacitance Switching frequency Safety meets
Max.
24 48 110
-0.02 25% load step change Zener diode clamp
GENERAL SPECIFICATIONS Parameter Isolation voltage
Typ.
9 18 43
8 16 40 60 60
Positive logic DC-DC ON (Standard) DC-DC OFF DC-DC ON Negative logic (Option) DC-DC OFF Input current of Ctrl pin Remote off input current
OUTPUT SPECIFICATIONS Parameter
Min.
Typ.
3000 1600 1600 1600 1 225
MIL-HDBK-217F, Full load.
Max.
VDC VDC
250
GΩ pF kHz UL60950-1 EN60950-1 IEC60950-1 Copper FR4 PCB Silicone (UL94 V-0) 32g (1.13oz) 9.073 x 105 hrs 1500 275
Advice Electronics Ltd Advice Building,16 Atir Yeda St., Kfar Saba, 4464321, Israel Tel:+972-3-9000910
[email protected]
Unit
www.advice.co.il
FED40W ENVIRONMENTAL SPECIFICATIONS Parameter Operating ambient temperature Maximum case temperature Over temperature protection Storage temperature range Thermal impedance (1)
Conditions
Min.
Typ.
-40
Max.
+115 -55 Vertical direction by natural convection (20LFM)
Without Heat-sink With Heat-sink
Thermal shock Shock Vibration Relative humidity
+125 10.8 10.3
/W
MIL-STD-810F EN61373, MIL-STD-810F EN61373, MIL-STD-810F 5% to 95% RH
EMC SPECIFICATIONS Parameter EMI (2) ESD Radiated immunity Fast transient (3) Surge (3) Conducted immunity Power frequency magnetic field
Conditions EN55011,EN55022 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8
Level Class A Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A
Air ± 8kV and Contact ± 6kV 20 V/m ± 2kV ± 2kV 10 Vr.m.s 100A/m continuous; 1000A/m 1 second
Note: 1. 2. 3.
Unit
+85 +105
Test by minimum input and constant resistive load. The standard module meets EMI Class A or Class B with external components. For further information, please contact with P-DUKE. The external input components are required if the module has to meet EN61000-4-4, EN61000-4-5. The FED40-24W recommended an aluminum electrolytic capacitor (Nippon chemi-con KY series, 220µF/100V) and a TVS (SMDJ58A, 58V, 3000Watt peak pulse power) to connect in parallel. The FED40-48W recommended an aluminum electrolytic capacitor (Nippon chemi-con KY series, 220µF/100V) and a TVS (SMDJ120A,120V, 3000Watt peak pulse power) to connect in parallel. The FED40-110W recommended an aluminum electrolytic capacitor (Ruby-con BXF series, 68µF/200V 3pcs in parallel) and a TVS (SMDJ90A, 90V, 3000Watt peak pulse power 2pcs in series connection ) to connect in parallel
CAUTION: This power module is not internally fused. An input line fuse must always be used.
CHARACTERISTIC CURVE
FED40-48S05W Derating Curve
FED40-48S05W Derating Curve with Heat-sink
FED40-48S05W Efficiency vs. Input Voltage
FED40-48S05W Efficiency vs. Output Load
Advice Electronics Ltd Advice Building,16 Atir Yeda St., Kfar Saba, 4464321, Israel Tel:+972-3-9000910
[email protected]
www.advice.co.il
FED40W MECHANICAL DRAWING PIN CONNECTION PIN SINGLE 1 + Vin 2 - Vin 3 Ctrl 4 + Vout 5 - Vout 6 Trim
DUAL + Vin - Vin Ctrl + Vout Common - Vout
EXTERNAL OUTPUT TRIMMING Output can be externally trimmed by using the method shown below. TRIM UP
TRIM DOWN
6
6 RU
5
RD 4
1. All dimensions in inch (mm) 2. Tolerance :x.xx±0.02 (x.x±0.5) x.xxx±0.01 (x.xx±0.25) 3. Pin pitch tolerance ±0.01 (0.25) 4. Pin dimension tolerance ±0.004(0.1)
Advice Electronics Ltd Advice Building,16 Atir Yeda St., Kfar Saba, 4464321, Israel Tel:+972-3-9000910
[email protected]
www.advice.co.il