Preview only show first 10 pages with watermark. For full document please download

Spec. Fed60

   EMBED


Share

Transcript

FED60 SERIES DC-DC CONVERTER 2:1 WIDE INPUT RANGE UP TO 60Watts FEATURES APPLICATIONS • NO MINIMUM LOAD REQUIRED • 1600VDC INPUT TO OUTPUT ISOLATION • STANDARD 2.00 X 1.00 X 0.40 INCH • SIX-SIDED CONTINUOUS SHIELD • SAFETY MEETS UL60950-1, EN60950-1, IEC60950-1, & EN50155 • CE MARKED • COMPLIANT TO RoHS II & REACH 1600VDC ISOLATION REMOTE CONTROL UVP • WIRELESS NETWORK • TELECOM/DATACOM • INDUSTRY CONTROL SYSTEM • DISTRIBUTED POWER ARCHITECTURES • SEMICONDUCTOR EQUIPMENT OCP SCP OVP OTP LOW STANDBY POWER TECHNICAL SPECIFICATION All specifications are typical at nominal input, full load and 25℃ otherwise noted Model Number FED60-12S3P3 FED60-12S05 FED60-12S12 FED60-12S15 FED60-12S24 FED60-12D12 FED60-12D15 FED60-12D24 FED60-24S3P3 FED60-24S05 FED60-24S12 FED60-24S15 FED60-24S24 FED60-24D12 FED60-24D15 FED60-24D24 FED60-48S3P3 FED60-48S05 FED60-48S12 FED60-48S15 FED60-48S24 FED60-48D12 FED60-48D15 FED60-48D24 Input Range Output Voltage Output Current @Full Load Input Current @ No Load Efficiency Maximum Capacitor Load (1) VDC 9 ~ 18 9 ~ 18 9 ~ 18 9 ~ 18 9 ~ 18 9 ~ 18 9 ~ 18 9 ~ 18 18 ~ 36 18 ~ 36 18 ~ 36 18 ~ 36 18 ~ 36 18 ~ 36 18 ~ 36 18 ~ 36 36 ~ 75 36 ~ 75 36 ~ 75 36 ~ 75 36 ~ 75 36 ~ 75 36 ~ 75 36 ~ 75 VDC 3.3 5 12 15 24 ±12 ±15 ±24 3.3 5 12 15 24 ±12 ±15 ±24 3.3 5 12 15 24 ±12 ±15 ±24 A 12 12 5 4 2.5 ±2.5 ±2 ±1.25 12 12 5 4 2.5 ±2.5 ±2 ±1.25 12 12 5 4 2.5 ±2.5 ±2 ±1.25 mA 15 15 15 15 15 15 15 15 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 % 89 90 90 91 92 90 90 91 90 92 91 92 91 90 90 91 90 92 92 92 92 91 91 91 µF 32000 30000 5850 3900 2000 ±3900 ±2400 ±1000 32000 30000 5850 3900 2000 ±3900 ±2400 ±1000 32000 30000 5850 3900 2000 ±3900 ±2400 ±1000 PART NUMBER STRUCTURE FED60 Series Name 48 Input Voltage (VDC) 12: 9~18 24: 18~36 48: 36~75 S Output Quantity S: Single D: Dual 05 Output Voltage (VDC) 3P3: 3.3 05: 5 12: 12 15: 15 24: 24 12: ±12 15: ±15 24: ±24 - N HS Remote Control options : Positive logic N: Negative logic Assembly Option : None HS: Heat-sink HC: Heat-sink with Clamp Advice Electronics Ltd Advice Building,16 Atir Yeda St., Kfar Saba, 4464321, Israel Tel:+972-3-9000910 [email protected] www.advice.co.il FED60 INPUT SPECIFICATIONS Parameter Conditions Operating input voltage range 12Vin(nom) 24Vin(nom) 48Vin(nom) 12Vin(nom) 24Vin(nom) 48Vin(nom) 12Vin(nom) 24Vin(nom) 48Vin(nom) Power up Remote ON/OFF 12Vin(nom) 24Vin(nom) 48Vin(nom) Start-up voltage Shutdown voltage Start up time Constant resistive load Input surge voltage 1 second, max. Input filter Remote ON/OFF Referred to –Vin pin Conditions Voltage accuracy Line regulation Load regulation Low Line to High Line at Full Load No Load to Full Load Cross regulation Voltage adjustability Asymmetrical load 25%/100% FL Single output Ripple and noise Measured by 20MHz bandwidth With a 10µF/25V X7R MLCC With a 10µF/25V X7R MLCC With a 4.7µF/50V X7R MLCC Temperature coefficient Transient response recovery time Over voltage protection Over load protection Short circuit protection Isolation resistance Isolation capacitance Switching frequency Safety meets Case material Base material Potting material Weight MTBF Max. 12 24 48 18 36 75 9 18 36 -0.5 Min. Typ. -1.0 -0.2 -0.5 -1.0 -5.0 -10 -10 3.3Vout, 5Vout 12Vout, 15Vout 24Vout 75 100 150 3.3Vout 5Vout 12Vout 15Vout 24Vout % of Iout rated; Hiccup mode Conditions Input to Output Input (Output) to Case 1 minute 500VDC VDC VDC ms VDC mA mA Max. Unit +1.0 +0.2 +0.5 +1.0 +5.0 +10 +20 % % 100 125 200 +0.02 % % % mVp-p %/℃ 250 µs 3.9 6.2 15 VDC 20 30 150 % Continuous, automatics recovery Min. Typ. 1600 1600 1 225 MIL-HDBK-217F, Full load. Max. [email protected] Unit VDC 250 GΩ pF kHz UL60950-1 EN60950-1 IEC60950-1 Copper FR4 PCB Silicone (UL94 V-0) 33g (1.16oz) 8.804 x 105 hrs 2200 275 Advice Electronics Ltd Advice Building,16 Atir Yeda St., Kfar Saba, 4464321, Israel Tel:+972-3-9000910 Unit VDC 25 50 100 Pi type Open or 3 ~ 12VDC Short or 0 ~ 1.2VDC Short or 0 ~ 1.2VDC Open or 3 ~ 12VDC 0.5 3 -0.02 25% load step change Zener diode clamp GENERAL SPECIFICATIONS Parameter Isolation voltage Single Dual Dual 3.3Vout, 5Vout, 12Vout 15Vout, 24Vout Typ. 9 18 36 8 16 32 60 60 Positive logic DC-DC ON (Standard) DC-DC OFF Negative logic DC-DC ON (Option) DC-DC OFF Input current of Ctrl pin Remote off input current OUTPUT SPECIFICATIONS Parameter Min. www.advice.co.il FED60 ENVIRONMENTAL SPECIFICATIONS Parameter Operating ambient temperature Maximum case temperature Over temperature protection Storage temperature range Thermal impedance Conditions Min. With Derating Typ. -40 Max. Unit +105 +105 ℃ ℃ ℃ ℃ +115 -55 Vertical direction by natural convection (20LFM) Without Heat-sink WIith Heat-sink +125 10.8 10.3 Thermal shock Vibration Relative humidity ℃/W MIL-STD-810F MIL-STD-810F 5% to 95% RH EMC SPECIFICATIONS Parameter EMI (2) ESD Radiated immunity Fast transient (3) Surge (3) Conducted immunity Power frequency magnetic field Conditions EN55022 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 Level Class A Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Air ± 8kV and Contact ± 6kV 20 V/m ± 2kV ± 2kV 10 Vr.m.s 100A/m continuous; 1000A/m 1 second Note: 1. 2. 3. Test by minimum input and constant resistive load. The standard module meets EMI Class A or Class B with external components. For further information, please contact with P-DUKE. The external input components are required if the module has to meet EN61000-4-4, EN61000-4-5. The FED60-12 and The FED60-24 recommended an aluminum electrolytic capacitor (Nippon chemi-con KY series, 220µF/100V) and a TVS (SMDJ58A, 58V, 3000Watt peak pulse power) to connect in parallel. The FED60-48 recommended an aluminum electrolytic capacitor (Nippon chemi-con KY series, 220µF/100V) and a TVS (SMDJ120A, 120V, 3000Watt peak pulse power) to connect in parallel. CAUTION: This power module is not internally fused. An input line fuse must always be used. CHARACTERISTIC CURVE FED60-48S12 Derating Curve FED60-48S12 Derating Curve with Heat-sink FED60-48S12 Efficiency VS Input Voltage FED60-48S12 Efficiency VS Output Load Advice Electronics Ltd Advice Building,16 Atir Yeda St., Kfar Saba, 4464321, Israel Tel:+972-3-9000910 [email protected] www.advice.co.il FED60 MECHANICAL DRAWING PIN CONNECTION PIN SINGLE 1 +Vin 2 -Vin 3 Ctrl 4 +Vout 5 -Vout 6 Trim DUAL +Vin -Vin Ctrl +Vout Common -Vout EXTERNAL OUTPUT TRIMMING Output can be externally trimmed by using the method shown below. TRIM UP TRIM DOWN 6 6 RU 5 RD 4 1. All dimensions in inch (mm) 2. Tolerance :x.xx±0.02 (x.x±0.5) x.xxx±0.01 (x.xx±0.25) 3. Pin pitch tolerance ±0.01 (0.25) 4. Pin dimension tolerance ±0.004(0.1) Advice Electronics Ltd Advice Building,16 Atir Yeda St., Kfar Saba, 4464321, Israel Tel:+972-3-9000910 [email protected] www.advice.co.il