Preview only show first 10 pages with watermark. For full document please download

Spec Sheet: Glxx-2dim8 - 8 Channel Dimmer Module

   EMBED


Share

Transcript

GLXX-2DIM8 8 Channel Dimmer Module The GLXX-2DIM8 is a Crestron Green Light Express® dimming module which features 8 channels of incandescent, magnetic low-voltage, 2- and 3-wire fluorescent, and LED[1] dimming. The module is part of a complete Crestron engineered GLPX Green Light Express dimming or switching panel. For more information on Crestron Green Light commercial lighting products, please contact Crestron Sales Support Services. > 8 channels of incandescent, MLV, ELV[2], 2-wire fluorescent, LED[1] dimming > 4 channels of 3-wire fluorescent dimming > Phase-Synchronous detection eliminates lamp flicker > Selectable non-dim mode > Supports 100 to 277 Volt applications Power Requirements > 16 Amp load rating per channel Primary: 100-277 Volts AC, 50/60Hz, supplied via channel 1 (L1, N1) Secondary (optional): 5 watts at 24 Volts DC, supplied via Cresnet® > Short circuit and overload protection Connectors > Local controls for testing and verification NET: (2) 4-pin 3.5mm detachable terminal blocks, Cresnet port; (2) 5-pin headers, connect to adjacent module or internal connecting block using interconnect cable (block and cable provided) OVR: (2) 2-pin 3.5mm detachable terminal blocks, paralleled, comprising (2) inputs for external contact closures to engage override mode N1 - N2: (2) terminal blocks, line input neutral L1 - L2: (2) terminal blocks, line power inputs DM1 - DM8: (8) terminal blocks, dim channel outputs Note: Line power terminal blocks accept 10-26 AWG wire; torque to 5.31 lbin (0.6 Nm); > Local and remote override capability Controls & Indicators > Positive air gap at each output > Phase-independent channels > Cresnet® communications > Redundant power capability—module powered via line or Cresnet > Non-volatile power failure memory > GLEX cabinet installation SPECIFICATIONS Load Ratings Dimmer Channels: 8 Per Channel: 16 Amps at 100-277 Volts AC, 50/60 Hz Lighting Per Group: Channels 1-4: 16 Amps (1920 Watts); Channels 5-8: 16 Amps (1920 Watts) Motor Per Group: Channels 1-4: 1 hp @ 120 Volts, 2 hp @ 230/277 Volts; Channels 5-8: 1 hp @ 120 Volts, 2 hp @ 230/277 Volts Note: Do not mix motor and lighting loads in same group. Dim Load Types: Incandescent, Magnetic Low-Voltage, Electronic Low-Voltage[2], Neon/Cold Cathode, 2-wire Fluorescent Ballast, 3-wire Fluorescent Ballast (uses adjacent channel for 3rd wire, i.e. channels 1 & 2 are to be used for one 3-wire load), LED[1] Switch Load Types: Incandescent, Magnetic Low-Voltage, Electronic LowVoltage, Neon/Cold Cathode, Fluorescent Ballast, High-Intensity Discharge, LED [1] , Motor www.crestron.com 800.237.2041 NET ID: (2) 7-Segment green LED digits and (2) miniature pushbuttons for setting Cresnet ID; SETUP: (1) Red LED and (1) recessed miniature pushbutton for enabling setup mode and touch-settable ID OVR: (1) Red LED and (1) miniature pushbutton for enabling override mode and saving override presets PWR: (1) Green LED; solid illumination indicates line power is applied to N1 and L1; flashing indicates Cresnet power is supplied in absence of line power NET: (1) Yellow LED; indicates communication with control processor RESET: (1) Recessed miniature pushbutton, resets internal processor Channel Section: 1-8: (1) Red LED per each channel, indicates channel is at a non-zero level; (8) miniature pushbuttons for individual manual channel activation DIM/3 WIRE FL/NON-DIM: (8) recessed miniature switches for setting channel mode; When set to "3 WIRE FL" the adjacent channel will be used for the 3rd wire; when set to "NON-DIM" module will ignore dim commands GLXX-2DIM8 8 Channel Dimmer Module Enclosure Surface mount module with (2) integral mounting flanges; mounts in a GLEX enclosure Environmental Temperature: 32° to 104°F (0° to 40°C) Humidity: 10% to 90% RH (non-condensing) Heat Dissipation: 154 BTU/Hr Dimensions Height: 11.07 in (281 mm) Width: 7.99 in (203 mm) Depth: 3.5 in (89 mm) Electrical Regulatory Certifications UL508, Section 41 (Endurance Test) and Section 61C (Electronic Ballasts) UL924, Emergency Power Equipment IEC60669-2-1, Section 19.102 (Contact mechanisms incorporated in electronic switches, intended for fluorescent lamp circuits or other capacitive loads) SCCR Rating - 65kA CE Notes: 1. For a list of compatible ballasts, visit www.crestron. com/lightingcompatibility (PDF). 2. Forward phase or leading edge compatible transformers only. This product may be purchased from an authorized Crestron dealer. To find a dealer, please contact the Crestron sales representative for your area. A list of sales representatives is available online at www.crestron. com/salesreps or by calling 800-237-2041. Specifications subject to change without notice. Crestron is not responsible for errors in typography or photography. Crestron, the Crestron logo, Cresnet and Green Light Express are trademarks or registered trademarks of Crestron Electronics, Inc. in the United States, other countries or both. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims proprietary interest in the marks and names of others. ©2011 Crestron Electronics, Inc. Crestron Electronics, Inc. 15 Volvo Drive | Rockleigh, NJ 07647 Tel: 800.237.2041 / 201.767.3400 | Fax: 201.767.1905 www.crestron.com GLXX-2DIM8 8 Channel Dimmer Module Crestron Electronics, Inc. 15 Volvo Drive | Rockleigh, NJ 07647 Tel: 800.237.2041 / 201.767.3400 | Fax: 201.767.1905 www.crestron.com All brand names, product names and trademarks are the property of their respective owners. ©2013 Crestron Electronics, Inc. Specifications subject to change without notice. 3/20/2013