Preview only show first 10 pages with watermark. For full document please download

Spec. Ufed40w

   EMBED


Share

Transcript

UFED40W UFED40W SERIES DC-DC CONVERTER 4:1 ULTRA WIDE INPUT RANGE UP TO 40Watts FEATURES APPLICATIONS • NO MINIMUM LOAD REQUIRED • 1600VDC INPUT TO OUTPUT ISOLATION • APPLICATION OF CHASSIS-MOUNT DC/DC CONVERTERS • SCREW TERMINALS FOR INPUT AND OUTPUT CONNECTIONS • INTERNAL INPUT FUSE PROTECTION • INTERNAL OUTPUT LED INDICATOR • MEET EN55022 CLASS B • SAFETY MEETS UL60950-1, EN60950-1, & IEC60950-1 • COMPLIANCE TO EN50155 AND EN45545-2 RAILWAY STANDARD • CE MARKED • COMPLIANT TO RoHS II & REACH 1600VDC ISOLATION REMOTE CONTROL OCP SCP UVP • RAILWAY SYSTEM • WIRELESS NETWORK • TELECOM/DATACOM • INDUSTRY CONTROL SYSTEM • MEASUREMENT EQUIPMENT • SEMICONDUCTOR EQUIPMENT OVP FUSE INCLUDED INRUSH LIMIT REVERSE POLARITY PROTECTION LOW STANDBY POWER TECHNICAL SPECIFICATION All specifications are typical at nominal input, full load and 25℃ otherwise noted Model Number UFED40-24S3P3W UFED40-24S05W UFED40-24S12W UFED40-24S15W UFED40-24S24W UFED40-24D12W UFED40-24D15W UFED40-24D24W UFED40-48S3P3W UFED40-48S05W UFED40-48S12W UFED40-48S15W UFED40-48S24W UFED40-48D12W UFED40-48D15W UFED40-48D24W UFED40-110S3P3W UFED40-110S05W UFED40-110S12W UFED40-110S15W UFED40-110S24W UFED40-110D12W UFED40-110D15W UFED40-110D24W Input Range Output Voltage Output Current @Full Load Input Current @ No Load Efficiency Maximum Capacitor Load (1) VDC 9.5 ~ 36 9.5 ~ 36 9.5 ~ 36 9.5 ~ 36 9.5 ~ 36 9.5 ~ 36 9.5 ~ 36 9.5 ~ 36 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 43 ~ 160 43 ~ 160 43 ~ 160 43 ~ 160 43 ~ 160 43 ~ 160 43 ~ 160 43 ~ 160 VDC 3.3 5 12 15 24 ±12 ±15 ±24 3.3 5 12 15 24 ±12 ±15 ±24 3.3 5 12 15 24 ±12 ±15 ±24 mA 10000 8000 3333 2666 1666 ±1666 ±1333 ±833 10000 8000 3333 2666 1666 ±1666 ±1333 ±833 10000 8000 3333 2666 1666 ±1666 ±1333 ±833 mA 19 19 19 19 19 19 19 19 14 14 14 14 14 14 14 14 10 10 10 10 10 10 10 10 % 89 90 91 91 90 89 89 90 89 90 91 91 90 89 89 90 87 88 89.5 90 89 88 88 90 µF 26600 20000 3900 2600 1300 ± 2600 ± 1600 ±650 26600 20000 3900 2600 1300 ± 2600 ± 1600 ±650 26600 20000 3900 2600 1300 ± 2600 ± 1600 ±650 PART NUMBER STRUCTURE UFED40 Series Name 48 Input Voltage (VDC) 24: 9.5~36 48: 18~75 110: 43~160 S Output Quantity S: Single D: Dual 05 Output Voltage (VDC) 3P3: 3.3 05: 5 12: 12 15: 15 24: 24 12: ±12 15: ±15 24: ±24 W Input Range 4:1 N EC Remote Control Option Assembly Option : Positive logic N: Negative logic : EC: DR: ED: None Enclosed Mounting Type Din Rail Mounting Type Enclosed & Din Rail Mounting Type Advice Electronics Ltd Advice Building,16 Atir Yeda St., Kfar Saba, 4464321, Israel Tel:+972-3-9000910 [email protected] www.advice.co.il UFED40W INPUT SPECIFICATIONS Parameter Conditions Operating input voltage range 24Vin(nom) 48Vin(nom) 110Vin(nom) 24Vin(nom) 48Vin(nom) 110Vin(nom) Input fuse (slow blow) In-rush current Start-up voltage 24Vin(nom) 48Vin(nom) 110Vin(nom) 24Vin(nom) 48Vin(nom) 110Vin(nom) Power up Remote ON/OFF 24Vin(nom) 48Vin(nom) 110Vin(nom) Positive logic DC-DC ON (Standard) DC-DC OFF Negative logic DC-DC ON (Option) DC-DC OFF Input current of CTRL pin Remote off input current Shutdown voltage Start up time Constant resistive load Input surge voltage 1 second, max. Remote ON/OFF Referenced to –Vin pin OUTPUT SPECIFICATIONS Parameter Conditions Voltage accuracy Low Line to High Line at Full Load Cross regulation Voltage adjustability Asymmetrical load 25%/100% FL Single output Ripple and noise Measured by 20MHz bandwidth Temperature coefficient Transient response recovery time Over voltage protection Output indicator Over load protection Short circuit protection No Load to Full Load Max. Unit 24 48 110 8 4 2 15 36 75 160 VDC A 9.5 18 43 8 16 40 100 60 -0.5 VDC VDC ms 50 100 VDC 170 Open or 3 ~ 12VDC Short or 0 ~ 1.2VDC Short or 0 ~ 1.2VDC Open or 3 ~ 12VDC 1 mA 5 mA Typ. -1.5 -1.0 -0.5 -1.5 -1.0 -5.0 -10 -10 3.3Vout, 5Vout Others Dual 3.3Vout, 5Vout, 12Vout 15Vout, 24Vout 3.3Vout, 5Vout 12Vout, 15Vout 24Vout A Max. Unit +1.5 +1.0 +0.5 +1.5 +1.0 +5.0 +10 +20 % 75 100 150 % % % % mVp-p -0.02 25% load step change Zener diode clamp +0.02 %/℃ 250 µs 3.9 6.2 15 VDC 20 30 Green LED 150 % Continuous, automatics recovery 3.3Vout 5Vout 12Vout 15Vout 24Vout % of Iout rated GENERAL SPECIFICATIONS Parameter Isolation voltage 1 minute Isolation resistance Isolation capacitance Switching frequency Safety meets 500VDC Chassis material Weight MTBF Typ. 9.5 18 43 Min. 3.3Vout Others Line regulation Load regulation Min. Conditions Min. Input to Output Input (Output) to Chassis Typ. 1600 1600 1 225 MIL-HDBK-217F, Full load Max. VDC 4000 250 GΩ pF 275 kHz UL60950-1 EN60950-1 IEC60950-1 EN50155 Aluminum 110g (3.88oz) 1.944 x 106 hrs Advice Electronics Ltd Advice Building,16 Atir Yeda St., Kfar Saba, 4464321, Israel Tel:+972-3-9000910 [email protected] Unit www.advice.co.il UFED40W ENVIRONMENTAL SPECIFICATIONS Parameter Conditions Operating ambient temperature Over temperature protection Storage temperature range Thermal shock Shock Vibration Relative humidity Max. Unit +63 +96 ℃ ℃ +105 ℃ MIL-STD-810F EN61373, MIL-STD-810F EN61373, MIL-STD-810F 5% to 95% RH +115 -40 Conditions EN55022 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 Typ. -40 +63 Case of DC/DC module EMC SPECIFICATIONS Parameter EMI ESD Radiated immunity Fast transient Surge Conducted immunity Power frequency magnetic field Min. without derating with derating Level Air ± 8kV and Contact ± 6kV 20 V/m ± 2kV ± 1kV 10 Vr.m.s 100A/m continuous; 1000A/m 1 second Class B Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Note: 1. Test by minimum input and constant resistive load. CHARACTERISTIC CURVE UFED40-48S05W Derating Curve UFED40-48S05W Efficiency vs. Input Voltage UFED40-48S05W Efficiency vs. Output Load Advice Electronics Ltd Advice Building,16 Atir Yeda St., Kfar Saba, 4464321, Israel Tel:+972-3-9000910 [email protected] www.advice.co.il UFED40W MECHANICAL DRAWING CHASSIS MOUNTING TYPE PIN CONNECTION PIN SINGLE DUAL 1 +Vin +Vin 2 -Vin -Vin 3 Ctrl Ctrl 4 NC NC 5 -Vout -Vout 6 +Vout Common 7 NC +Vout ※ NC:No Connection ※ Screw terminals – wire range from 14 to 18 AWG ENCLOSED MOUNTING TYPE DIN RAIL MOUNTING TYPE 1. All dimensions in Inch (mm) 2. Tolerance : X.XX±0.02 (X.X±0.5) 4. Tolerance : X.XXX±0.01 (X.XX±0.25) 3. Hole screw locked torque : MAX 5.0kgf-cm (0.49N-m) 4. Terminal screw locked torque : MAX 2.5kgf-cm (0.25N-m) Advice Electronics Ltd Advice Building,16 Atir Yeda St., Kfar Saba, 4464321, Israel Tel:+972-3-9000910 [email protected] www.advice.co.il