Transcript
URED20W SERIES DC-DC CONVERTER 4:1 ULTRA WIDE INPUT RANGE UP TO 20 Watts
FEATURES
APPLICATIONS
• NO MINIMUM LOAD REQUIRED • 1600VDC INPUT TO OUTPUT ISOLATION • APPLICATION OF CHASSIS-MOUNT DC/DC CONVERTERS • SCREW TERMINALS FOR INPUT AND OUTPUT CONNECTIONS • INTERNAL INPUT FUSE PROTECTION • INTERNAL OUTPUT LED INDICATOR • MEET EN55022 CLASS B • SAFETY MEETS UL60950-1, EN60950-1, & IEC60950-1 • COMPLIANCE TO EN50155 AND EN45545-2 RAILWAY STANDARD • CE MARKED • COMPLIANT TO RoHS II & REACH
1600VDC ISOLATION
REMOTE CONTROL
OCP SCP
UVP
• RAILWAY SYSTEM • WIRELESS NETWORK • TELECOM/DATACOM • INDUSTRY CONTROL SYSTEM • MEASUREMENT EQUIPMENT • SEMICONDUCTOR EQUIPMENT
OVP
FUSE INCLUDED
INRUSH LIMIT
REVERSE POLARITY PROTECTION
TECHNICAL SPECIFICATION All specifications are typical at nominal input, full load and 25℃ Model Number URED20-24S3P3W URED20-24S05W URED20-24S12W URED20-24S15W URED20-24D12W URED20-24D15W URED20-48S3P3W URED20-48S05W URED20-48S12W URED20-48S15W URED20-48D12W URED20-48D15W URED20-110S3P3W URED20-110S05W URED20-110S12W URED20-110S15W URED20-110D12W URED20-110D15W
LOW STANDBY POWER
otherwise noted
Input Range
Output Voltage
Output Current @Full Load
Input Current @ No Load
Efficiency
VDC 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 43 ~ 160 43 ~ 160 43 ~ 160 43 ~ 160 43 ~ 160 43 ~ 160
VDC 3.3 5 12 15 ±12 ±15 3.3 5 12 15 ±12 ±15 3.3 5 12 15 ±12 ±15
mA 4500 4000 1670 1330 ± 833 ± 667 4500 4000 1670 1330 ± 833 ± 667 4500 4000 1670 1330 ± 833 ± 667
mA 8 8 8 8 8 8 6 6 6 6 6 6 5 5 5 5 5 5
% 84 87 88 87 87 88 84 87 88 88 87 88 84 86 87 87 87 88
Maximum Capacitor Load (1) µF 7000 5000 850 700 ± 500 ± 350 7000 5000 850 700 ± 500 ± 350 7000 5000 850 700 ± 500 ± 350
PART NUMBER STRUCTURE
URED20 Series Name
48 Input Voltage (VDC) 24: 9~36 48: 18~75 110: 43~160
S Output Quantity S: Single
D: Dual
05 Output Voltage (VDC) 3P3: 3.3 05: 5 12: 12 15: 15 12: ±12 15: ±15
W Input Range 4:1
N
EC
Remote Control Option
Assembly Option
: Positive logic N: Negative logic
: EC: DR: ED:
None Enclosed Mounting Type Din Rail Mounting Type Enclosed & Din Rail Mounting Type
Advice Electronics Ltd Advice Building,16 Atir Yeda St., Kfar Saba, 4464321, Israel Tel:+972-3-9000910
[email protected]
www.advice.co.il
URED20W INPUT SPECIFICATIONS Parameter
Conditions
Operating input voltage range
24Vin(nom) 48Vin(nom) 110Vin(nom) 24Vin(nom) 48Vin(nom) 110Vin(nom)
Input fuse (slow blow)
In-rush current Input reflected ripple current Start up voltage
Start up time
Constant resistive load
Input surge voltage
1 second, max.
24Vin(nom) 48Vin(nom) 110Vin(nom) 24Vin(nom) 48Vin(nom) 110Vin(nom) Power up Remote ON/OFF 24Vin(nom) 48Vin(nom) 110Vin(nom) Positive logic DC-DC ON (Standard) DC-DC OFF Negative logic DC-DC ON (Option) DC-DC OFF Input current of Ctrl pin Remote off input current
Referenced to –Vin pin
OUTPUT SPECIFICATIONS Parameter
Conditions
Voltage accuracy Line regulation
Low Line to High Line at Full Load
Load regulation
No Load to Full Load
Cross regulation Voltage adjustability Ripple and noise Temperature coefficient Transient response recovery time Over voltage protection
Asymmetrical load 25%/100% FL Single output Measured by 20MHz bandwidth
Output indicator Over load protection Short circuit protection
Max.
Unit
24 48 110 6 4 2 15 30
36 75 160
VDC
A mAp-p 9 18 43
VDC ms
50 100 170 Open or 3 ~ 15VDC Short or 0 ~ 1.2VDC Short or 0 ~ 1.2VDC Open or 3 ~ 15VDC -0.5 1 5
Typ.
-1.5 -1.0 -0.2 -0.5 -1.5 -1.0 -5.0 -10
3.3Vout 5Vout 12Vout 15Vout
% of Iout rated
Conditions
Isolation voltage
1 minute
Isolation resistance Isolation capacitance Switching frequency Safety meets
500VDC
Input to Output Input (Output) to Chassis
VDC
mA mA
Max.
Unit
+1.5 +1.0 +0.2 +0.5 +1.5 +1.0 +5.0 10
%
75
25% load step change Zener diode clamp
VDC
8 16 40 100 30
Min. 3.3Vout Others Single Dual 3.3Vout Others Dual
A
-0.02
GENERAL SPECIFICATIONS Parameter
Chassis material Weight MTBF
Typ.
9 18 43
Nominal input and Full load
Shutdown voltage
Remote ON/OFF
Min.
% % % % mVp-p %/℃ µs
+0.02 250 3.9 6.2 VDC 15 20 Green LED 150 % Continuous, automatics recovery
Min.
Typ.
1600 1600 1 297
MIL-HDBK-217F, Full load
Max.
VDC 5000 330
GΩ pF 363 kHz UL60950-1 EN60950-1 IEC60950-1 Aluminum 105g (3.70oz) 1.338 x 106 hrs
Advice Electronics Ltd Advice Building,16 Atir Yeda St., Kfar Saba, 4464321, Israel Tel:+972-3-9000910
[email protected]
Unit
www.advice.co.il
URED20W ENVIRONMENTAL SPECIFICATIONS Parameter
Conditions
Operating ambient temperature
Min. without derating with derating
Storage temperature range Thermal shock Shock Vibration Relative humidity
EMC SPECIFICATIONS Parameter EMI ESD Radiated immunity Fast transient Surge Conducted immunity Power frequency magnetic field
-40 +78 -40
Conditions EN55022 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8
Typ.
Max.
Unit
+78 ℃ +100 +105 ℃ MIL-STD-810F EN61373, MIL-STD-810F EN61373, MIL-STD-810F 5% to 95% RH
Level
Air ± 8kV and Contact ± 6kV 20V/m ± 2kV ± 1kV 10Vr.m.s 100A/m continuous; 1000A/m 1 second
Class B Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A
Note: 1.
Test by minimum input and constant resistive load.
CHARACTERISTIC CURVE
URED20-48S05W Derating Curve
URED20-48S05W Efficiency vs. Input Voltage
URED20-48S05W Efficiency vs. Output Load
Advice Electronics Ltd Advice Building,16 Atir Yeda St., Kfar Saba, 4464321, Israel Tel:+972-3-9000910
[email protected]
www.advice.co.il
URED20W MECHANICAL DRAWING CHASSIS MOUNTING TYPE PIN CONNECTION PIN SINGLE DUAL 1 +Vin +Vin 2 -Vin -Vin 3 Ctrl Ctrl 4 NC NC 5 -Vout -Vout 6 +Vout Common 7 NC +Vout ※ NC:No Connection ※ Screw terminals – wire range from 14 to 18 AWG
ENCLOSED MOUNTING TYPE
DIN RAIL MOUNTING TYPE 1. All dimensions in Inch (mm) 2. Tolerance : X.XX±0.02 (X.X±0.5) 4. Tolerance : X.XXX±0.01 (X.XX±0.25) 3. Hole screw locked torque : MAX 5.0kgf-cm (0.49N-m) 4. Terminal screw locked torque : MAX 2.5kgf-cm (0.25N-m)
Advice Electronics Ltd Advice Building,16 Atir Yeda St., Kfar Saba, 4464321, Israel Tel:+972-3-9000910
[email protected]
www.advice.co.il