Preview only show first 10 pages with watermark. For full document please download

Specdt70pw401r3

   EMBED


Share

Transcript

Desktop Specification Rev 3, 12/22/99 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Specification Nominal Output Voltage (7) Minimum Output Current Maximum Output Current Maximum Peak Current (1) Maximum Output Power Input Voltage Range Efficiency (2) Inrush current - Maximum (3) Adjustment Range Maximum Ripple & Noise (4) Total regulation Overcurrent Protection (5) Overvoltage Protection (6) Hold up time - 115VAC Leakage Current Operating Temperature Storage Temperature EMI Safety Other Size (L x W x H) Input connector Output cable Output connector V A A A W V % A V mV mV ms mA C C mm mm - - 25 Signals - 26 Color - Model DT70PW401 Output 1 Output 2 Output 3 Output 4 +5 +12 -12 +5sb 2 0.2 0 0 7 1.5 0.3 0.75 9 60W (Peak 70W) 90 ~ 264VAC (47 ~ 63Hz) >70% at full load 25 None 50mV 120mV 120mV 100mV +/-3% +/-5% +/-5% +/-3% Short Circuit on each output 5V>5.6V~6.5V 16ms at full load < 3.5mA 0 ~ 45C -20 ~ 70C FCC Class B, EN55022B UL1950, CSA 22.2 234, EN60950 CE Mark 155 (6.11") x 85 (3.35") x 50 (1.97") Mates with IEC320/C13 (3 wire) 600 PLT-168-P Pins 1 & 2 +5V Pin 3 +12V Pin 4 & 8, 0V Pin 5, -12V Pin 6, Remote on-off Pin 7, 5VSB Remote on-off (outputs 1, 2, & 3 only) Short to 0V for "on" Black Notes: 1 Peak current lasting for 2 secs maximum Average power not to exceed rated maximum. 2 At 100VAC or 200VAC input and maximum output power 3 4 5 6 7 At 115VAC input cold start at 25C Measured across 10uF electrolytic in parallel with 0.1uF ceramic at DC plug Avoid prolonged operation in overload Zener Diode protected Output 4 is standby voltage (on when unit is remotely turned off)