Transcript
RQ-65
65W Quad Output Switching Power Supply
series
¡½ Features :
¡EUniversal AC input / Full range ¡ Protections:Short circuit / Overload / Over voltage E ¡ Cooling by free air convection E ¡ LED indicator for power on E ¡ 100% full load burn-in test E ¡ All using 105¢J long life electrolytic capacitors E ¡ Withstand 300VAC surge input for 5 second E ¡ High operating temperature up to 70¢J E ¡ Withstand 5G vibration test E ¡ High efficiency, long life and high reliability E ¡ 3 years warranty E ..
SPECIFICATION MODEL
OUTPUT
INPUT
RQ-65B CH2
CH3
CH4
CH1
CH2
CH3
CH4
CH1
CH2
CH3
DC VOLTAGE
5V
12V
-5V
-12V
5V
15V
-5V
-15V
5V
12V
24V
-12V
RATED CURRENT
6A
2A
0.5A
0.5A
5A
2A
0.5A
0.5A
4A
1.5A
1A
0.5A
0.2 ~ 3A
0 ~ 1A
0 ~ 1A
0.5 ~ 8A
0.2 ~ 3A
0 ~ 1A
0 ~ 1A
0.5 ~ 8A
0.2 ~ 3A
0.1 ~ 1.5A 0 ~ 1A
CURRENT RANGE
Note.6 0.5 ~ 8A
RATED POWER
Note.6 62.5W
65W
CH4
68W
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 80mVp-p 80mVp-p 80mVp-p 120mVp-p 80mVp-p 80mVp-p 80mVp-p 120mVp-p 180mVp-p 80mVp-p VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V +9,-5% VOLTAGE TOLERANCE Note.3 ¡Ó2.0%
¡Ó5.0%
¡Ó5.0%
CH1: 4.75 ~ 5.5V ¡Ó2.0% +10,-4% ¡Ó5.0%
¡Ó5.0%
CH1: 4.75 ~ 5.5V ¡Ó2.0% ¡Ó6.0%
¡Ó8.0%
¡Ó5.0%
¡Ó0.5%
¡Ó0.5%
¡Ó1.5%
¡Ó0.5%
¡Ó0.5%
¡Ó0.5%
¡Ó1.5%
¡Ó2.0%
¡Ó0.5%
¡Ó1.0%
¡Ó0.5%
¡Ó4.0%
¡Ó1.0%
¡Ó1.0%
¡Ó0.5%
¡Ó3.0%
¡Ó5.0%
¡Ó1.0%
LINE REGULATION
Note.4 ¡Ó0.5%
¡Ó1.5%
¡Ó0.5%
LOAD REGULATION
Note.5 ¡Ó0.5%
¡Ó3.0%
¡Ó1.0%
SETUP, RISE TIME
500ms, 20ms/230VAC
HOLD UP TIME (Typ.)
60ms/230VAC
VOLTAGE RANGE
88 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
76%
AC CURRENT (Typ.) INRUSH CURRENT (Typ.)
2A/115VAC 1.2A/230VAC COLD START 40A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 7) EMC EMISSION
NOTE
RQ-65D
CH1
PROTECTION
OTHERS
RQ-65C
OUTPUT NUMBER
1200ms, 30ms/115VAC at full load
14ms/115VAC at full load 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) 76%
78%
110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70¢J (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85¢J, 10 ~ 95% RH ¡Ó0.03%/¢J (0 ~ 50¢J)on +5V output 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25¢J/ 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
MTBF
245.5Khrs min.
DIMENSION PACKING
129*98*38mm (L*W*H) 0.44Kg; 30pcs/13.2Kg/0.72CUFT
MIL-HDBK-217F (25¢J)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¢J of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load. 6. Each output can work within current range. But total output power can't exceed rated output power. 7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
File Name:RQ-65-SPEC 2013-03-04
RQ-65
65W Quad Output Switching Power Supply Mechanical Specification
Case No. 903
series
Unit:mm
31
3.5
7
122.5
1
33
4 5
98
2-
M3
3
85.5
8.25
2
7
6 7 8
£r3 .5 73.5
4.5
129
6.5
Terminal Pin No. Assignment
32
Pin No. 1 2 3 4
38
28.5
3
3.5
9.5
.5
3-M
18
£r3
18.5
9
120
Assignment AC/L AC/N FG DC OUTPUT -V4
Pin No. 5 6 7 8
Assignment DC OUTPUT V3 DC OUTPUT +V2 DC OUTPUT COM DC OUTPUT +V1
77
Block Diagram
RECTIFIERS & FILTER
EMI FILTER
I/P
POWER SWITCHING
RECTIFIERS & FILTER
+V4
RECTIFIERS & FILTER
+V3
RECTIFIERS & FILTER
+V2
RECTIFIERS & FILTER
+V1 COM
DETECTION CIRCUIT
FG O.L.P.
fosc : 60KHz
CONTROL
O.V.P.
Derating Curve
Output Derating VS Input Voltage
100
100
90 80
80 70
LOAD (%)
LOAD (%)
60 40
20
-25 -25
0 0
10
20
30
40
50
AMBIENT TEMPERATURE (¢J)
60
70 (VERTICAL)
60 50 40
88
95
100
115
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:RQ-65-SPEC 2013-03-04