Transcript
T- 4 0
40W Triple Output Switching Power Supply
series
Features : Universal AC input / Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection 100% full load burn-in test Fixed switching frequency at 40KHz 2 years warranty
SPECIFICATION MODEL
OUTPUT
INPUT
T-40A CH2
CH3
CH1
CH2
CH3
CH1
CH2
DC VOLTAGE
5V
12V
-5V
5V
12V
-12V
5V
15V
-15V
RATED CURRENT
3A
2A
0.5A
3A
2A
0.5A
3A
1.5A
0.5A
CURRENT RANGE
0.6 ~ 5A
0.2 ~ 3A
0.1 ~ 1A
0.6 ~ 5A
0.2 ~ 3A
0.1 ~ 1A
0.6 ~ 5A
0.2 ~ 2A
0.1 ~ 1A
RATED POWER
41.5W
120mVp-p
120mVp-p
RIPPLE & NOISE (max.) Note.2 100mVp-p
45W
100mVp-p
120mVp-p
CH1 : 4.75 ~ 5.5V 2.0% 6.0%
8.0%
120mVp-p 8.0%
100mVp-p
CH1 : 4.75 ~ 5.5V 2.0% 6.0%
6.0%
0.5%
1.0%
1.0%
0.5%
1.0%
1.0%
0.5%
1.0%
1.0%
LOAD REGULATION
0.5%
4.0%
6.0%
0.5%
4.0%
6.0%
0.5%
4.0%
4.0%
SETUP, RISE TIME
800ms, 50ms/230VAC
HOLD UP TIME (Typ.)
70ms/230VAC
VOLTAGE RANGE
85 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
72%/115VAC
AC CURRENT (Typ.) INRUSH CURRENT (Typ.)
1.2A/115VAC 0.7A/230VAC COLD START 20A/115VAC 40A/230VAC
1600ms, 50ms/115VAC at full load
16ms/115VAC at full load 120 ~ 370VDC 72%/115VAC
LEAKAGE CURRENT
<3.5mA / 240VAC
OVERLOAD
105 ~ 150%/115VAC rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V
TEMP. COEFFICIENT VIBRATION
NOTE
100mVp-p
CH3
LINE REGULATION
WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY
OTHERS
120mVp-p
CH1 : 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% 6.0%
WORKING TEMP.
(Note 4)
45W
VOLTAGE ADJ. RANGE
OVER VOLTAGE
EMC
T-40C
CH1
PROTECTION
SAFETY &
T-40B
OUTPUT NUMBER
72%/115VAC
Protection type : Hiccup mode, recovers automatically after fault condition is removed -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85
, 10 ~ 95% RH
SAFETY STANDARDS
0.03%/ (0 ~ 50 )on +5V output 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes CSA 60950-1, (UL60950-1, IEC60950-1, TUV EN60950-1) approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
/ 70% RH
HARMONIC CURRENT EMS IMMUNITY
Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
MTBF
305.6K hrs min. MIL-HDBK-217F (25 129*98*38mm (L*W*H) 0.44Kg; 30pcs/14.7Kg/0.86CUFT
DIMENSION PACKING
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
File Name:T-40-SPEC 2010-10-18
T- 4 0
40W Triple Output Switching Power Supply Mechanical Specification
Case No. 903
series
Unit:mm
122.5
31
3.5
7
4.5
1
9.5
2
85.5
33
4
8.2
5
98
2-
M3
3
6 7
3 .5 73.5
4.5
129
6.5
9.5
32
3
Pin No. 1 2 3 4
38
3.5
Terminal Pin No. Assignment 28.5
3.5
3-M
18
18.5
9
120
77
Block Diagram
RECTIFIERS & FILTER
EMI FILTER
I/P
POWER SWITCHING
FG O.L.P.
Pin No. Assignment DC OUTPUT +V2 5 6 DC OUTPUT COM 7 DC OUTPUT +V1
Assignment AC/L AC/N FG DC OUTPUT -V
RECTIFIERS & FILTER
-V3
RECTIFIERS & FILTER
+V2
RECTIFIERS & FILTER
+V1 COM
fosc : 40KHz
DETECTION CIRCUIT
PWM CONTROL
O.V.P.
Derating Curve
Static Characteristics (B) Ta=25
100
OUTPUT VOLTAGE (V)
-12V
80
60
LOAD (%)
300
5.2
40
20
12
250
5.0
+5V +12V
11
4.8
10
4.6
150
9
4.4
100
8
4.2
7
4.0
+12V +5V
200
50 25
OUTPUT RIPPLE (mVp-p)
13
-12V -10
0
10
20
30
40
50 45
AMBIENT TEMPERATURE ( )
60 55
(VERTICAL) (HORIZONTAL)
60
80
100
120
140
160
180
200
220
240
260
INPUT VOLTAGE (V) 60Hz
File Name:T-40-SPEC 2010-10-18