Preview only show first 10 pages with watermark. For full document please download

Specification

   EMBED


Share

Transcript

T- 4 0 40W Triple Output Switching Power Supply series Features : Universal AC input / Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection 100% full load burn-in test Fixed switching frequency at 40KHz 2 years warranty SPECIFICATION MODEL OUTPUT INPUT T-40A CH2 CH3 CH1 CH2 CH3 CH1 CH2 DC VOLTAGE 5V 12V -5V 5V 12V -12V 5V 15V -15V RATED CURRENT 3A 2A 0.5A 3A 2A 0.5A 3A 1.5A 0.5A CURRENT RANGE 0.6 ~ 5A 0.2 ~ 3A 0.1 ~ 1A 0.6 ~ 5A 0.2 ~ 3A 0.1 ~ 1A 0.6 ~ 5A 0.2 ~ 2A 0.1 ~ 1A RATED POWER 41.5W 120mVp-p 120mVp-p RIPPLE & NOISE (max.) Note.2 100mVp-p 45W 100mVp-p 120mVp-p CH1 : 4.75 ~ 5.5V 2.0% 6.0% 8.0% 120mVp-p 8.0% 100mVp-p CH1 : 4.75 ~ 5.5V 2.0% 6.0% 6.0% 0.5% 1.0% 1.0% 0.5% 1.0% 1.0% 0.5% 1.0% 1.0% LOAD REGULATION 0.5% 4.0% 6.0% 0.5% 4.0% 6.0% 0.5% 4.0% 4.0% SETUP, RISE TIME 800ms, 50ms/230VAC HOLD UP TIME (Typ.) 70ms/230VAC VOLTAGE RANGE 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 72%/115VAC AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.2A/115VAC 0.7A/230VAC COLD START 20A/115VAC 40A/230VAC 1600ms, 50ms/115VAC at full load 16ms/115VAC at full load 120 ~ 370VDC 72%/115VAC LEAKAGE CURRENT <3.5mA / 240VAC OVERLOAD 105 ~ 150%/115VAC rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V TEMP. COEFFICIENT VIBRATION NOTE 100mVp-p CH3 LINE REGULATION WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY OTHERS 120mVp-p CH1 : 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% 6.0% WORKING TEMP. (Note 4) 45W VOLTAGE ADJ. RANGE OVER VOLTAGE EMC T-40C CH1 PROTECTION SAFETY & T-40B OUTPUT NUMBER 72%/115VAC Protection type : Hiccup mode, recovers automatically after fault condition is removed -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH SAFETY STANDARDS 0.03%/ (0 ~ 50 )on +5V output 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes CSA 60950-1, (UL60950-1, IEC60950-1, TUV EN60950-1) approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B / 70% RH HARMONIC CURRENT EMS IMMUNITY Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A MTBF 305.6K hrs min. MIL-HDBK-217F (25 129*98*38mm (L*W*H) 0.44Kg; 30pcs/14.7Kg/0.86CUFT DIMENSION PACKING ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) File Name:T-40-SPEC 2010-10-18 T- 4 0 40W Triple Output Switching Power Supply Mechanical Specification Case No. 903 series Unit:mm 122.5 31 3.5 7 4.5 1 9.5 2 85.5 33 4 8.2 5 98 2- M3 3 6 7 3 .5 73.5 4.5 129 6.5 9.5 32 3 Pin No. 1 2 3 4 38 3.5 Terminal Pin No. Assignment 28.5 3.5 3-M 18 18.5 9 120 77 Block Diagram RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING FG O.L.P. Pin No. Assignment DC OUTPUT +V2 5 6 DC OUTPUT COM 7 DC OUTPUT +V1 Assignment AC/L AC/N FG DC OUTPUT -V RECTIFIERS & FILTER -V3 RECTIFIERS & FILTER +V2 RECTIFIERS & FILTER +V1 COM fosc : 40KHz DETECTION CIRCUIT PWM CONTROL O.V.P. Derating Curve Static Characteristics (B) Ta=25 100 OUTPUT VOLTAGE (V) -12V 80 60 LOAD (%) 300 5.2 40 20 12 250 5.0 +5V +12V 11 4.8 10 4.6 150 9 4.4 100 8 4.2 7 4.0 +12V +5V 200 50 25 OUTPUT RIPPLE (mVp-p) 13 -12V -10 0 10 20 30 40 50 45 AMBIENT TEMPERATURE ( ) 60 55 (VERTICAL) (HORIZONTAL) 60 80 100 120 140 160 180 200 220 240 260 INPUT VOLTAGE (V) 60Hz File Name:T-40-SPEC 2010-10-18