Preview only show first 10 pages with watermark. For full document please download

Specification

   EMBED


Share

Transcript

RD-85 85W Dual Output Switching Power Supply series ■ ‧ ‧ ‧ ‧ ‧ ‧℃ ‧ ‧℃ ‧ ‧ ‧ .. SPECIFICATION MODEL OUTPUT INPUT RD-85A RD-85B OUTPUT NUMBER CH1 CH2 CH1 CH2 DC VOLTAGE 5V 12V 5V 24V RATED CURRENT 8A 4A 8A 2A 0.3 ~ 5A 2 ~ 10A 0.3 ~ 2.5A CURRENT RANGE Note.6 2 ~ 10A RATED POWER Note.6 88W 88W RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 80mVp-p 120mVp-p CH1: 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 ±2.0% ±5.0% CH1: 4.75 ~ 5.5V ±2.0% ±5.0% LINE REGULATION Note.4 ±0.5% ±1.0% ±0.5% ±1.0% LOAD REGULATION Note.5 ±1.0% ±3.0% ±1.0% ±3.0% VOLTAGE ADJ. RANGE SETUP, RISE TIME 500ms, 20ms/230VAC HOLD UP TIME (Typ.) 100ms/230VAC VOLTAGE RANGE 88 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY(Typ.) 78% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2.5A/115VAC 1.5A/230VAC COLD START 40A/230VAC LEAKAGE CURRENT 1200ms, 30ms/115VAC at full load 18ms/115VAC at full load 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) 80% <2mA / 240VAC 110 ~ 150% rated output power OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 7) EMC EMISSION EMC IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70℃ (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85℃, 10 ~ 95% RH ±0.03%/℃ (0 ~ 50℃)on +5V output 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A 239.4Khrs min. MIL-HDBK-217F (25℃) 159*97*38mm (L*W*H) 0.6Kg; 24pcs/15.4Kg/0.7CUFT ℃          File Name:RD-85-SPEC 2011-08-19 RD-85 85W Dual Output Switching Power Supply Mechanical Specification Case No. 901C series Unit:mm 3.5 7 152.5 1 3 84.5 8.2 4 5 6 2-M 97 65 9.5 2 3 7 .5 ψ3 4.5 78 24 159 150 22 Pin No. 1 2 3 38 3.5 M3 28.5 3- Terminal Pin No. Assignment 18 .5 ψ3 18.5 9 9 6.5 Assignment AC/L AC/N FG Pin No. Assignment 4,6 DC OUTPUT COM 5 DC OUTPUT +V2 7 DC OUTPUT +V1 117 Block Diagram fosc : 60KHz RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING RECTIFIERS & FILTER +V2 RECTIFIERS & FILTER +V1 COM DETECTION CIRCUIT FG O.L.P. CONTROL O.V.P. Derating Curve Static Characteristics Ta=25℃ 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -25 -25 0 0 10 20 30 40 50 AMBIENT TEMPERATURE (℃) 60 70 (VERTICAL) 60 50 40 88 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:RD-85-SPEC 2011-08-19