Preview only show first 10 pages with watermark. For full document please download

Specification Approval Installation 9739mvd Iecex

   EMBED


Share

Transcript

Engineering Specification SPEC, APPVL INST 9739MVD IECEx EB-20019335 Revision: AA Number of Pages: 6 Comments: Originator: RCS 6/29/11 Approved: RCS 6/29/11 Rev ECN AA 1042090 Description Release to Approvals Approval Date RCS 6/29/11 THIS DOCUMENT IS CONFIDENTIAL, CONTAINS PROPRIETARY INFORMATION, AND SHOULD NOT BE DISTRIBUTED, COPIED OR OTHERWISE REPRODUCED WITHOUT THE EXPRESS WRITTEN CONSENT OF MICRO MOTION, INC. Micro Motion, Inc. Page 1 of 6 SPEC, APPVL INST 9739MVD IECEx Subject: Equipment type Manufactured and submitted for EB-20019335 Revision AA Transmitter type 9739MVD******** Micro Motion, Inc. examination Address Boulder, Co. 80301, USA Standard basis IEC60079-0:2007 IEC60079-1:2007 IEC60079-11:2006 Code for type of protection Ex d [ib] IIB/IIC T6 Gb [Ex ib Gb] IIB/IIC EC Type Examination Certificate IECEx BVS 11.0063 X General requirements Flameproof enclosure ´d´ Intrinsic safety ´i´ THIS DOCUMENT IS CONFIDENTIAL, CONTAINS PROPRIETARY INFORMATION, AND SHOULD NOT BE DISTRIBUTED, COPIED OR OTHERWISE REPRODUCED WITHOUT THE EXPRESS WRITTEN CONSENT OF MICRO MOTION, INC. Micro Motion, Inc. Page 2 of 6 SPEC, APPVL INST 9739MVD IECEx 1) EB-20019335 Revision AA Subject and Type Transmitter type 9739MVD******** Instead of the * in the complete denomination, letters and numerals will be inserted which characterize the following variations: 9 7 3 9 MV D 6 * * * * * * * Letters for factory options Language Letter for conduit connections Approval 3 = IECEx Intrinsically safe sensor outputs I = IECEx Intrinsically safe sensor outputs flameproof transmitter Display 1 = Dual Line Display 3 = No Display Power 6 = 12-30 VDC and 85-250 VAC (auto ranging) 2) Description The transmitter is, in combination with a sensor, used for measurement of mass flow and data transmission. The electrical circuitry of the transmitters is mounted inside a flameproof metal enclosure type 9739MVD6*I*****. The 9739MVD6*3***** is not a flameproof enclosure. THIS DOCUMENT IS CONFIDENTIAL, CONTAINS PROPRIETARY INFORMATION, AND SHOULD NOT BE DISTRIBUTED, COPIED OR OTHERWISE REPRODUCED WITHOUT THE EXPRESS WRITTEN CONSENT OF MICRO MOTION, INC. Micro Motion, Inc. Page 3 of 6 SPEC, APPVL INST 9739MVD IECEx 3) Parameters 3.1 Mains circuit (see document EB-20019903 for terminals) voltage max. voltage 3.2 EB-20019335 Revision AA Um AC/DC AC/DC 12 -250 V 250 V For Transmitter type 9739MVD6******* Intrinsically safe circuits type of protection Ex ib IIC / Ex ib IIB The circuits designed for connecting sensors are classified initially in Group IIC. However, when certain sensors are connected, they can also be assigned to Group IIB. 3.3.1 Drive circuit (see document EB-20019903 for terminals) voltage current power Internal resistance Uo Io Po Ri DC 10,5 1,04 2,11 10,12 V A W Ω type of protection Ex ib IIC max. external inductance max. external capacitance max. inductance/resistance ratio Lo Co Lo/Ro 33 2,41 13,05 μH μF μH/Ω type of protection Ex ib IIB max. external inductance max. external capacitance max. inductance/resistance ratio Lo Co Lo/Ro 131 16,8 52,6 μH μF μH/Ω The maximum external inductance L (sensor coil) can be calculated with the following term: L = 2 x E x ( Ri + Ro / 1,5 x Uo)2 Whereby E= 40µJ for group IIC and E = 160µJ for group IIB will be inserted and Ro is the total resistance (coil resistance + series resistance). THIS DOCUMENT IS CONFIDENTIAL, CONTAINS PROPRIETARY INFORMATION, AND SHOULD NOT BE DISTRIBUTED, COPIED OR OTHERWISE REPRODUCED WITHOUT THE EXPRESS WRITTEN CONSENT OF MICRO MOTION, INC. Micro Motion, Inc. Page 4 of 6 SPEC, APPVL INST 9739MVD IECEx EB-20019335 Revision AA 3.3.2 Pick-off circuits (see document EB-20019903 for terminals) voltage Uo current Io power Po 17,3 18,05 30 V mA mW type of protection Ex ib IIC max. external inductance max. external capacitance Lo Co 109 353 mH nF type of protection Ex ib IIB max. external inductance max. external capacitance Lo Co 436 2,06 mH μF 17,3 21 91 V mA mW 3.3.3 Temperature circuit (see document EB-20019903 for terminals) voltage Umax curent Imax power Pmax 3.4 DC DC type of protection Ex ib IIC max. external inductance max. external capacitance Lo Co 80,4 353 mH nF type of protection Ex ib IIB max. external inductance max. external capacitance Lo Co 322 2,06 mH μF Ambient temperature range: 9739MVD6******* Ta Ta -30 °C to +55 °C or -40 °C to +55 °C (routine test required, only for 9739MVD6*I*****) THIS DOCUMENT IS CONFIDENTIAL, CONTAINS PROPRIETARY INFORMATION, AND SHOULD NOT BE DISTRIBUTED, COPIED OR OTHERWISE REPRODUCED WITHOUT THE EXPRESS WRITTEN CONSENT OF MICRO MOTION, INC. Micro Motion, Inc. Page 5 of 6 SPEC, APPVL INST 9739MVD IECEx 4) EB-20019335 Revision AA Marking -30 °C ≤ Ta ≤ +55 °C for 9739MVD or -40 °C ≤ Ta ≤ +55 °C for 9739MVD (routine test required, only for 9739MVD**I*****) - type 9739MVD**I***** - type of protection 9739MVD**3***** [Ex ib Gb] IIC Ex d[ib] IIC T6 Gb 5) Special conditions for safe use / Installation instructions for 9739MVD**I*****. 5.1 For the application of the transmitter in an ambient temperature of less than - 20 °C suitable cable and cable entries or conduit entries certified for this condition shall be used. 5.2 If certified conduit entries are used for the connection of the transmitter enclosure, the associated stopping boxes shall be installed immediately at the enclosure. 5.3 The transmitter shall only be installed within the intended hazardous area if metal cable entries (with ¾”–14 NPT threading) are used which are classified as Ex d IIC and are for enclosures with >2dm3 and are certified by an authorized test station. 5.4 Entry holes which are not being used must be sealed with blanking plugs and which are classified as Ex d IIC and are certified by an authorized test station. 5.5 For installation outside the hazardous area, it is allowed to use cable entry fittings that are not flameproof. 5.6 The non-intrinsically safe end of the transmitter must only be connected to devices where there are no voltages higher than 250V. 6) Special conditions for safe use / Installation instructions for 9739MVD*(1,3)*****. 6.1 The transmitter must be installed outside the hazardous area in such a way that it meets at least the safety requirement IP20 according to IEC 60529. 6.2 The non-intrinsically safe end of the transmitter must only be connected to devices where there are no voltages higher than 250V. THIS DOCUMENT IS CONFIDENTIAL, CONTAINS PROPRIETARY INFORMATION, AND SHOULD NOT BE DISTRIBUTED, COPIED OR OTHERWISE REPRODUCED WITHOUT THE EXPRESS WRITTEN CONSENT OF MICRO MOTION, INC. Micro Motion, Inc. Page 6 of 6