Transcript
SFP 1310nm FP OC48 XCVR PRODUCT NUMBER: TSD-SXDA1-D11
Specification Small Form Factor Pluggable Duplex LC Receptacle – SFP Optical Transceivers STM-16 / OC-48 2488.32Mbit/s
Ordering Information
T S D - S x D A 1 - D 1 1
Category SD : DDMI Product
Model Name TSD-S1DA1-D11
Voltage / Temperature 1 : 3.3V / +0℃~ +70℃ 2 : 3.3V / -40 ℃~ +85℃
Voltage Category Device type Interface 3.3V
With DDMI
FP / PIN
TSD-S2DA1-D11
Copley Networks 709 Brea Canyon Rd., Suite #10 Walnut, CA 91789, USA Ph: +1-909-718-0988 Fax: +1-909-718-0508
AC / AC Coupling
Version 01 1
SD/LOS LVTTL
Temperature Distance Latch Color +0°C~+70°C
2km
Blue
-40°C~+85°C
Formerica Optoelectronics Inc 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118
SFP 1310nm FP OC48 XCVR PRODUCT NUMBER: TSD-SXDA1-D11 Features ROHS Compliant Standard Small Form Factor Pluggable Package – SFP MSA Compliant Digital Diagnostic SFF-8472 Rev.10.2 Compliant Gigabit Ethernet Standard ( IEEE802.3Z 1000BASE-LX ) Compliant Fibre Channel Standard ( 100-SM-LC-L ) Compliant Laser Class 1 Product – IEC60825-1 Compliant Standard Duplex LC Receptacle Optical Interface Single + 3.3 V Power Supply Differential LVPECL Data Input and Output LVTTL Loss of Signal Serial ID through I2C Interface Low Power Consumption
Absolute Maximum Ratings Parameter
Symbol
Min
Storage temperature
TS
Supply voltage
Max
Unit
-40
85
°C
VCC
0
4
V
-
5
95
%
VIN
0
VCC
V
Symbol
Min
Typ
Max
Unit
VCC
3.1
3.3
3.5
V
0
-
70
Operating Relative Humidity Input voltage
Typ
Operating Conditions Parameter Supply Voltage Operating Case temperature ( TSD-S1DA1-D11 )
Tc
Operating Case temperature ( TSD-S2DA1-D11 ) Total Current ( Transmitter + Receiver )
Copley Networks 709 Brea Canyon Rd., Suite #10 Walnut, CA 91789, USA Ph: +1-909-718-0988 Fax: +1-909-718-0508
Icc
Version 01 2
-40 -
85 -
250
ºC mA
Formerica Optoelectronics Inc 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118
SFP 1310nm FP OC48 XCVR PRODUCT NUMBER: TSD-SXDA1-D11 Transmitter Specifications ( VCC=3.1V~3.5V;Tc= 0oC~70oC / Tc= -40oC~85oC ) Parameter
Symbol
Min
Typ
Max
Unit
Output Optical Power
Pout
-9
--
-3
dBm
Extinction Ratio
ER
9
--
--
dB
Center Wavelength
λC
1270
1310
1355
nm
Spectral Width (RMS)
σ
--
--
4
nm
Rise/Fall time (20-80%)
Tr,f
--
--
160
ps
Relative Intensity Noise
RIN
--
--
-120
dB/Hz
Optical Characteristics
Compliant with ITU-T G.957
Output Eye POFF
--
--
-45
dBm
Differential Input Voltage
VDIFF
0.4
--
2.0
V
Tx_Disable_Input_High
VDISH
2.0
--
VCC+0.3
V
Tx_Disable_Input_Low
VDISL
0
--
0.8
V
Tx_Fault_Output_High
VFH
2.0
--
VCC+0.3
V
Tx_Fault_Output_Low
VFL
0
--
0.8
V
Max. Pout TX-DISABLE Asserted Electrical Characteristics
Receiver Specifications ( VCC=3.1V~3.5V;Tc= 0oC~70oC / Tc= -40oC~85oC ) Parameter
Symbol
Min
Typ
Max
Unit
PSATIN
-3
--
--
dBm
PSAN
--
--
-18
dBm
λc
1260
1610
nm
Optical Return Loss
ORL
12
--
--
dB
Loss of Signal – De-asserted
PLD
--
--
-18
dBm
Loss of Signal - Asserted
PLA
-35
--
--
dBm
Loss of Signal - Hysteresis
PLH
0.5
6
dB
Differential Output Voltage
VDIFF
0.4
--
2.0
V
Receiver Loss of Signal Output Voltage -Low
VLOSH
0
--
0.8
V
Receiver Loss of Signal Output Voltage -High
VLOSL
2
--
VCC+0.3
V
Optical Characteristics Optical Input Power-maximum 23
Receiver Sensitivity ( PRBS=2 -1;BER≦10
-10
)
Operating Center Wavelength
Electrical Characteristics
Copley Networks 709 Brea Canyon Rd., Suite #10 Walnut, CA 91789, USA Ph: +1-909-718-0988 Fax: +1-909-718-0508
Version 01 3
Formerica Optoelectronics Inc 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118
SFP 1310nm FP OC48 XCVR PRODUCT NUMBER: TSD-SXDA1-D11 Pin Definition and Descriptions
Pin
Name
Input/Output Level
1
VeeT
Input
2
TXFault
Output/LVTTL
3
TXDisable
Input/LVTTL
Description
4
MOD-DEF(2) Input/output
Transmitter ground Laser failure indication. High level indicates “laser failure”. Externally pulled up Transmitter disable, High signal/open disables TX laser output. Low level enables TX output, internally pulled up. Module definition 2, SDA, Data line for I2C bus. Externally pulled up
5
MOD-DEF(1) Input
Module definition 1, SCL, Clock for I2C bus. Externally pulled up
6
MOD-DEF(0) Output
Module definition 0, Module present. Ground inside module.
7
Rate Select
-
No connection.
8
LOS
Output/LVTTL
Receiver loss of signal indication. Low signal indicates optical signal is present at RX input. Should be Externally pulled up.
9
VeeR
Input
Receiver ground
10
VeeR
Input
Receiver ground
11
VeeR
Input
Receiver ground
12
RD -
Output/LVPECL
Inverted receiver data output (AC coupled)
13
RD +
Output/LVTTL
Non-inverted receiver data output (AC coupled)
14
VeeR
Input
Receiver ground
15
VccR
Input
Receiver power supply
16
VccT
Input
Transmitter power supply
17
VeeT
Input
Transmitter ground
18
TD +
Input/LVPECL
non-inverted transmitter data input (AC coupled)
19
TD -
Input/LVPECL
Inverted transmitter data input (AC coupled)
20
VeeT
Input
Transmitter ground
Copley Networks 709 Brea Canyon Rd., Suite #10 Walnut, CA 91789, USA Ph: +1-909-718-0988 Fax: +1-909-718-0508
Version 01 4
Formerica Optoelectronics Inc 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118
SFP 1310nm FP OC48 XCVR PRODUCT NUMBER: TSD-SXDA1-D11 Recommended Circuit Diagram
3.3V
VccT 4.7KΩ to 10KΩ
VeeT TxDisable
3
TxFault
2
Laser Diode Laser Diode Driver
4.7KΩ to 10KΩ
1,17,20
TD+
18
TD-
19
VccT
16
100Ω
1µΗ 0.1µF
VccR
RD -
Limiting Amplifier
10µF
0.1µF
SerDes IC
1µΗ
15
0.1µF
10µF
Photo Diode
3.3V
Protocol IC
12 100Ω
RD+
13
TIA 3.3V
MCU
A0H / A2H
SFP Transceiver
LOS
8
MOD-DEF2
4
MOD-DEF1
5
MOD-DEF0
6
VeeR
Copley Networks 709 Brea Canyon Rd., Suite #10 Walnut, CA 91789, USA Ph: +1-909-718-0988 Fax: +1-909-718-0508
4.7KΩ to 10KΩ
4.7KΩ to 10KΩ
4.7KΩ to 10KΩ
4.7KΩ to 10KΩ
PLD/PAL
9,10,11,14
System
Version 01 5
Formerica Optoelectronics Inc 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118
SFP 1310nm FP OC48 XCVR PRODUCT NUMBER: TSD-SXDA1-D11 Content in 2-Wire Address A0H Address 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 ~ 35 36 37 ~ 39 40 ~ 55 56 ~ 59 60 ~ 61 62 63 64 65 66 67 68 ~ 83 84 ~ 89 90 ~ 91 92 93 94 95 96~127
HEX Name of Field 03 Identifier 04 Extended Identifier 07 Connector type 00 Infiniband Compliance Codes 11 SONET Compliance Codes 00 SONET Compliance Codes 00 Ethernet Compliance Codes 00 Fiber Channel link length 00 Fiber Channel transmitter technology 00 Fiber Channel transmission media 00 Fiber Channel speed 03 Encoding codes: 19 Nominal Bit Rate (units of 100Mbps) 00 Rate identifier 02 Link length supported for 9um fiber 14 Link length supported for 9um fiber 00 Link length supported for 50um,OM2 00 Link length supported for 62.5um,OM1 00 Link length supported for copper 00 Link length supported for 50um,OM3 46,4F,52,4D,45,52,49,43 ,41,4F,45,20,20,20,20,20 Vendor Name 00 Unallocated 00,00,00 Vendor OUI 54,53,44,2D,53,31(32),44,41,31, Part Number 2D,44,31,31,20,20,20 00,00,00,00 Vendor Revision number 05,1E Laser Wavelength 00 Unallocated CC_BASE: 00 Options 1A Options 00 Bit Rate, max. 00 Bit Rate, min. Serial Number Serial Number yy/mm/dd Date Code 20,20 Vendor specific lot code 68 Diagnostic Monitoring Type B0 Enhanced Options (soft) 03 SFF-8472 Compliance CC_EXT Vendor specific
Copley Networks 709 Brea Canyon Rd., Suite #10 Walnut, CA 91789, USA Ph: +1-909-718-0988 Fax: +1-909-718-0508
Version 01 6
Description SFP SFP LC Not compliant SONET SR-1 compliant OC-48, short reach Not compliant Not compliant Not compliant Not compliant Not compliant NRZ 2488Mbps Unspecified 2 (units of km) 20 (units of 100m) N/A (units of 10m) N/A(units of 10m) N/A (units of 1m) N/A (units of 10m) FORMERICAOE Unspecified TSD-S1(2)DA1-D11 Unspecified 1310nm Check sum of byte 0 ~ 62 TX-DIS, TX_FAULT, RX-LOS Unspecified Unspecified
Unspecified Internal calibration All flags, TX_FAULT, RX-LOS Rev10.2 Check sum of byte 64 ~ 94
Formerica Optoelectronics Inc 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118
SFP 1310nm FP OC48 XCVR PRODUCT NUMBER: TSD-SXDA1-D11 Content in 2-Wire Address A2H Add
Bytes
Name
Hex
Real Value
00-01 02-03 04-05 06-07 08-09 10-11 12-13 14-15 16-17 18-19 20-21 22-23 24-25 26-27 28-29 30-31 32-33 34-35 36-37 38-39 40-55 56-59 60-63 64-67 68-71 72-75 76-77 78-79 80-81 82-83 84-85 86-87 88-89 90-91 92-94 95
2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 16 4 4 4 4 4 2 2 2 2 2 2 2 2 3 1
Temp High Alarm* Temp Low Alarm* Temp High Warning* Temp Low Warning* Voltage High Alarm Voltage Low Alarm Voltage High Warning Voltage Low Warning Bias High Alarm Bias Low Alarm Bias High Warning Bias Low Warning TX Power High Alarm TX Power Low Alarm TX Power High Warning TX Power Low Warning RX Power High Alarm RX Power Low Alarm RX Power High Warning RX Power Low Warning Reserved RX_PWR(4) RX_PWR(3) RX_PWR(2) RX_PWR(1) RX_PWR(0) TX_I(Slope) TX_I(Offset) TX_PWR(Slope) TX_PWR(Offset) T(Slope) T(Offset) V(Slope) V(Offset) Reserved Checksum
5500 (6400) 0000 (D800) 5000 (5F00) 0A00 (E200) 8CA0 7530 88B8 7918 AFC8 09C4 9C40 0DAC 2710 0277 18A6 03E8 1F07 0064 1394 009E 00 00000000 00000000 00000000 3F800000 00000000 0100 0000 0100 0000 0100 0000 0100 0000 00
85℃ (100℃) 0℃ (-40℃) 80℃ (95℃) 10℃ (-30℃) 3.6V 3.0V 3.5V 3.1V 90mA 5mA 80mA 7mA 0dBm -12dBm -2dBm -10dBm -1dBm -20dBm -3dBm -18dBm 0 0 0 1 0 1 0 1 0 1 0 1 0 -
Note *: ( ) for TSD-S2DA1-D11.
Copley Networks 709 Brea Canyon Rd., Suite #10 Walnut, CA 91789, USA Ph: +1-909-718-0988 Fax: +1-909-718-0508
Version 01 7
Formerica Optoelectronics Inc 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118
SFP 1310nm FP OC48 XCVR PRODUCT NUMBER: TSD-SXDA1-D11 Mechanical Outlines
( Unit : mm)
Copley Networks 709 Brea Canyon Rd., Suite #10 Walnut, CA 91789, USA Ph: +1-909-718-0988 Fax: +1-909-718-0508
Version 01 8
Formerica Optoelectronics Inc 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118