Preview only show first 10 pages with watermark. For full document please download

Specification - Formerica Optoelectronics

   EMBED


Share

Transcript

SFP 1310nm FP OC48 XCVR PRODUCT NUMBER: TSD-SXDA1-D11 Specification Small Form Factor Pluggable Duplex LC Receptacle – SFP Optical Transceivers STM-16 / OC-48 2488.32Mbit/s Ordering Information T S D - S x D A 1 - D 1 1 Category SD : DDMI Product Model Name TSD-S1DA1-D11 Voltage / Temperature 1 : 3.3V / +0℃~ +70℃ 2 : 3.3V / -40 ℃~ +85℃ Voltage Category Device type Interface 3.3V With DDMI FP / PIN TSD-S2DA1-D11 Copley Networks 709 Brea Canyon Rd., Suite #10 Walnut, CA 91789, USA Ph: +1-909-718-0988 Fax: +1-909-718-0508 AC / AC Coupling Version 01 1 SD/LOS LVTTL Temperature Distance Latch Color +0°C~+70°C 2km Blue -40°C~+85°C Formerica Optoelectronics Inc 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 SFP 1310nm FP OC48 XCVR PRODUCT NUMBER: TSD-SXDA1-D11 Features ROHS Compliant Standard Small Form Factor Pluggable Package – SFP MSA Compliant Digital Diagnostic SFF-8472 Rev.10.2 Compliant Gigabit Ethernet Standard ( IEEE802.3Z 1000BASE-LX ) Compliant Fibre Channel Standard ( 100-SM-LC-L ) Compliant Laser Class 1 Product – IEC60825-1 Compliant Standard Duplex LC Receptacle Optical Interface Single + 3.3 V Power Supply Differential LVPECL Data Input and Output LVTTL Loss of Signal Serial ID through I2C Interface Low Power Consumption Absolute Maximum Ratings Parameter Symbol Min Storage temperature TS Supply voltage Max Unit -40 85 °C VCC 0 4 V - 5 95 % VIN 0 VCC V Symbol Min Typ Max Unit VCC 3.1 3.3 3.5 V 0 - 70 Operating Relative Humidity Input voltage Typ Operating Conditions Parameter Supply Voltage Operating Case temperature ( TSD-S1DA1-D11 ) Tc Operating Case temperature ( TSD-S2DA1-D11 ) Total Current ( Transmitter + Receiver ) Copley Networks 709 Brea Canyon Rd., Suite #10 Walnut, CA 91789, USA Ph: +1-909-718-0988 Fax: +1-909-718-0508 Icc Version 01 2 -40 - 85 - 250 ºC mA Formerica Optoelectronics Inc 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 SFP 1310nm FP OC48 XCVR PRODUCT NUMBER: TSD-SXDA1-D11 Transmitter Specifications ( VCC=3.1V~3.5V;Tc= 0oC~70oC / Tc= -40oC~85oC ) Parameter Symbol Min Typ Max Unit Output Optical Power Pout -9 -- -3 dBm Extinction Ratio ER 9 -- -- dB Center Wavelength λC 1270 1310 1355 nm Spectral Width (RMS) σ -- -- 4 nm Rise/Fall time (20-80%) Tr,f -- -- 160 ps Relative Intensity Noise RIN -- -- -120 dB/Hz Optical Characteristics Compliant with ITU-T G.957 Output Eye POFF -- -- -45 dBm Differential Input Voltage VDIFF 0.4 -- 2.0 V Tx_Disable_Input_High VDISH 2.0 -- VCC+0.3 V Tx_Disable_Input_Low VDISL 0 -- 0.8 V Tx_Fault_Output_High VFH 2.0 -- VCC+0.3 V Tx_Fault_Output_Low VFL 0 -- 0.8 V Max. Pout TX-DISABLE Asserted Electrical Characteristics Receiver Specifications ( VCC=3.1V~3.5V;Tc= 0oC~70oC / Tc= -40oC~85oC ) Parameter Symbol Min Typ Max Unit PSATIN -3 -- -- dBm PSAN -- -- -18 dBm λc 1260 1610 nm Optical Return Loss ORL 12 -- -- dB Loss of Signal – De-asserted PLD -- -- -18 dBm Loss of Signal - Asserted PLA -35 -- -- dBm Loss of Signal - Hysteresis PLH 0.5 6 dB Differential Output Voltage VDIFF 0.4 -- 2.0 V Receiver Loss of Signal Output Voltage -Low VLOSH 0 -- 0.8 V Receiver Loss of Signal Output Voltage -High VLOSL 2 -- VCC+0.3 V Optical Characteristics Optical Input Power-maximum 23 Receiver Sensitivity ( PRBS=2 -1;BER≦10 -10 ) Operating Center Wavelength Electrical Characteristics Copley Networks 709 Brea Canyon Rd., Suite #10 Walnut, CA 91789, USA Ph: +1-909-718-0988 Fax: +1-909-718-0508 Version 01 3 Formerica Optoelectronics Inc 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 SFP 1310nm FP OC48 XCVR PRODUCT NUMBER: TSD-SXDA1-D11 Pin Definition and Descriptions Pin Name Input/Output Level 1 VeeT Input 2 TXFault Output/LVTTL 3 TXDisable Input/LVTTL Description 4 MOD-DEF(2) Input/output Transmitter ground Laser failure indication. High level indicates “laser failure”. Externally pulled up Transmitter disable, High signal/open disables TX laser output. Low level enables TX output, internally pulled up. Module definition 2, SDA, Data line for I2C bus. Externally pulled up 5 MOD-DEF(1) Input Module definition 1, SCL, Clock for I2C bus. Externally pulled up 6 MOD-DEF(0) Output Module definition 0, Module present. Ground inside module. 7 Rate Select - No connection. 8 LOS Output/LVTTL Receiver loss of signal indication. Low signal indicates optical signal is present at RX input. Should be Externally pulled up. 9 VeeR Input Receiver ground 10 VeeR Input Receiver ground 11 VeeR Input Receiver ground 12 RD - Output/LVPECL Inverted receiver data output (AC coupled) 13 RD + Output/LVTTL Non-inverted receiver data output (AC coupled) 14 VeeR Input Receiver ground 15 VccR Input Receiver power supply 16 VccT Input Transmitter power supply 17 VeeT Input Transmitter ground 18 TD + Input/LVPECL non-inverted transmitter data input (AC coupled) 19 TD - Input/LVPECL Inverted transmitter data input (AC coupled) 20 VeeT Input Transmitter ground Copley Networks 709 Brea Canyon Rd., Suite #10 Walnut, CA 91789, USA Ph: +1-909-718-0988 Fax: +1-909-718-0508 Version 01 4 Formerica Optoelectronics Inc 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 SFP 1310nm FP OC48 XCVR PRODUCT NUMBER: TSD-SXDA1-D11 Recommended Circuit Diagram 3.3V VccT 4.7KΩ to 10KΩ VeeT TxDisable 3 TxFault 2 Laser Diode Laser Diode Driver 4.7KΩ to 10KΩ 1,17,20 TD+ 18 TD- 19 VccT 16 100Ω 1µΗ 0.1µF VccR RD - Limiting Amplifier 10µF 0.1µF SerDes IC 1µΗ 15 0.1µF 10µF Photo Diode 3.3V Protocol IC 12 100Ω RD+ 13 TIA 3.3V MCU A0H / A2H SFP Transceiver LOS 8 MOD-DEF2 4 MOD-DEF1 5 MOD-DEF0 6 VeeR Copley Networks 709 Brea Canyon Rd., Suite #10 Walnut, CA 91789, USA Ph: +1-909-718-0988 Fax: +1-909-718-0508 4.7KΩ to 10KΩ 4.7KΩ to 10KΩ 4.7KΩ to 10KΩ 4.7KΩ to 10KΩ PLD/PAL 9,10,11,14 System Version 01 5 Formerica Optoelectronics Inc 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 SFP 1310nm FP OC48 XCVR PRODUCT NUMBER: TSD-SXDA1-D11 Content in 2-Wire Address A0H Address 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 ~ 35 36 37 ~ 39 40 ~ 55 56 ~ 59 60 ~ 61 62 63 64 65 66 67 68 ~ 83 84 ~ 89 90 ~ 91 92 93 94 95 96~127 HEX Name of Field 03 Identifier 04 Extended Identifier 07 Connector type 00 Infiniband Compliance Codes 11 SONET Compliance Codes 00 SONET Compliance Codes 00 Ethernet Compliance Codes 00 Fiber Channel link length 00 Fiber Channel transmitter technology 00 Fiber Channel transmission media 00 Fiber Channel speed 03 Encoding codes: 19 Nominal Bit Rate (units of 100Mbps) 00 Rate identifier 02 Link length supported for 9um fiber 14 Link length supported for 9um fiber 00 Link length supported for 50um,OM2 00 Link length supported for 62.5um,OM1 00 Link length supported for copper 00 Link length supported for 50um,OM3 46,4F,52,4D,45,52,49,43 ,41,4F,45,20,20,20,20,20 Vendor Name 00 Unallocated 00,00,00 Vendor OUI 54,53,44,2D,53,31(32),44,41,31, Part Number 2D,44,31,31,20,20,20 00,00,00,00 Vendor Revision number 05,1E Laser Wavelength 00 Unallocated CC_BASE: 00 Options 1A Options 00 Bit Rate, max. 00 Bit Rate, min. Serial Number Serial Number yy/mm/dd Date Code 20,20 Vendor specific lot code 68 Diagnostic Monitoring Type B0 Enhanced Options (soft) 03 SFF-8472 Compliance CC_EXT Vendor specific Copley Networks 709 Brea Canyon Rd., Suite #10 Walnut, CA 91789, USA Ph: +1-909-718-0988 Fax: +1-909-718-0508 Version 01 6 Description SFP SFP LC Not compliant SONET SR-1 compliant OC-48, short reach Not compliant Not compliant Not compliant Not compliant Not compliant NRZ 2488Mbps Unspecified 2 (units of km) 20 (units of 100m) N/A (units of 10m) N/A(units of 10m) N/A (units of 1m) N/A (units of 10m) FORMERICAOE Unspecified TSD-S1(2)DA1-D11 Unspecified 1310nm Check sum of byte 0 ~ 62 TX-DIS, TX_FAULT, RX-LOS Unspecified Unspecified Unspecified Internal calibration All flags, TX_FAULT, RX-LOS Rev10.2 Check sum of byte 64 ~ 94 Formerica Optoelectronics Inc 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 SFP 1310nm FP OC48 XCVR PRODUCT NUMBER: TSD-SXDA1-D11 Content in 2-Wire Address A2H Add Bytes Name Hex Real Value 00-01 02-03 04-05 06-07 08-09 10-11 12-13 14-15 16-17 18-19 20-21 22-23 24-25 26-27 28-29 30-31 32-33 34-35 36-37 38-39 40-55 56-59 60-63 64-67 68-71 72-75 76-77 78-79 80-81 82-83 84-85 86-87 88-89 90-91 92-94 95 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 16 4 4 4 4 4 2 2 2 2 2 2 2 2 3 1 Temp High Alarm* Temp Low Alarm* Temp High Warning* Temp Low Warning* Voltage High Alarm Voltage Low Alarm Voltage High Warning Voltage Low Warning Bias High Alarm Bias Low Alarm Bias High Warning Bias Low Warning TX Power High Alarm TX Power Low Alarm TX Power High Warning TX Power Low Warning RX Power High Alarm RX Power Low Alarm RX Power High Warning RX Power Low Warning Reserved RX_PWR(4) RX_PWR(3) RX_PWR(2) RX_PWR(1) RX_PWR(0) TX_I(Slope) TX_I(Offset) TX_PWR(Slope) TX_PWR(Offset) T(Slope) T(Offset) V(Slope) V(Offset) Reserved Checksum 5500 (6400) 0000 (D800) 5000 (5F00) 0A00 (E200) 8CA0 7530 88B8 7918 AFC8 09C4 9C40 0DAC 2710 0277 18A6 03E8 1F07 0064 1394 009E 00 00000000 00000000 00000000 3F800000 00000000 0100 0000 0100 0000 0100 0000 0100 0000 00 85℃ (100℃) 0℃ (-40℃) 80℃ (95℃) 10℃ (-30℃) 3.6V 3.0V 3.5V 3.1V 90mA 5mA 80mA 7mA 0dBm -12dBm -2dBm -10dBm -1dBm -20dBm -3dBm -18dBm 0 0 0 1 0 1 0 1 0 1 0 1 0 - Note *: ( ) for TSD-S2DA1-D11. Copley Networks 709 Brea Canyon Rd., Suite #10 Walnut, CA 91789, USA Ph: +1-909-718-0988 Fax: +1-909-718-0508 Version 01 7 Formerica Optoelectronics Inc 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 SFP 1310nm FP OC48 XCVR PRODUCT NUMBER: TSD-SXDA1-D11 Mechanical Outlines ( Unit : mm) Copley Networks 709 Brea Canyon Rd., Suite #10 Walnut, CA 91789, USA Ph: +1-909-718-0988 Fax: +1-909-718-0508 Version 01 8 Formerica Optoelectronics Inc 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118