Preview only show first 10 pages with watermark. For full document please download

Specification Htl Online Ups 10k En

   EMBED


Share

Transcript

UPS Series HI-TOP 31 The Data Centers Diamond Advice Electronics LTD brings you the perfect solution for electrical blackouts and protection!!! An ON-LINE double convertion UPS System, with plenty of exclusive advantages and guaranteed payback investment, using the "Eco Mode" feature, that decreases the electrical consumption and saves up to thousands of NIS yearly in your electricity bill. Features: • • • • • • • • • • • • • • • • • • • • • • 3 phase input and 1 phase output ON LINE Double conversion technology RPA – Redundent Parallel Architecture N+1 IGBT technology, PWM topology Smart controller - Digital Signal Processor (DSP) Wide input range Increased input Power Factor (>0.99) Intelligent Battery Management System to extend battery life time Low Total Harmonic Distrotion (THD) Level Small Dimentions, less Floor / Cabinet area space Smart Fan Speed Regulation depending on load By pass Expendable and Variable Battery blocks depending on backup time needed. Cold start Artificial intelligence algorithms to improve reliability and technical performance LCD Display, large variaty of data to user and ability to change parameters RS232 Communication and optional dry contact Including shutdown managenent software for Windows network servers Optional SNMP Net Agent card Optional Detectors: Humidity, Temperature, Smoke, Flooding Optional SMS notice Eco Mode – Energy Saving Mode Specifications Tower Model 19"Rack mount model Power (KVA) Power (KW) Input Output HTL3110 HTL3110RM 10 8 Nominal voltage Minimum voltage Minimum voltage (al full load) Maximum voltage Frequency Power factor Input current harmonics Power factor Nominal voltage Nominal current Wave form Total harmonic distortion at 100% linear load at 100% non-linear load Frequency Frequency tolerance (free running) 380V / 400V 277V 312V 485V 45-65 Hz ≥ 0.99 <7% 0.8 200V / 208V / 220V / 230V / 240V (adjustable) 45.5A Pure sine wave < 3% <5% 50 Hz or 60 Hz (adjustable) ±0.2% Static voltage regulation (0%-100% load) < 1% Transfer time Crest factor 0 Sec 3:1 Overload (on mains)(0-150% overload) Battery Protection Communication Interface Environment Total efficiency Eco Mode efficiency Type Number of batteries Recharging time Overload protection Short circuit protection Other protection RS-232 Dry contact SNMP Operating temperature Proposed temp. to extend battery life Humidity Audible noise at 1 m At 110% (2 min) / At 125% (5 sec) / At 150% (Bypass) ≥ 90% ≥ 97% Maintenace free lead acid batteries 20 pcs. 12V batteries (240VDC) 4h – 6h up to 90% Inverter supply: 105%-150% for 160 secons ~ 2 cycles before switching bypass Bypass supply: 105%-200% for 500 seconds ~ 8 cycles before stopping supply load Switch off immediately Overheat, battery low standart optional optional 0 C ….+40C 20-25 C Up to 90% (non condensing) <50dB Tower type Net weight (kg) Physical Specifications Standards Dimensions (mm) (WxDxH) 28Kg (without batteries) 132 x 810 x 440 (UPS Only) 19" rack mount type Net weight (kg) Dimensions (mm) (WxDxH) Safety EMC Performance Other Protection class * Product specifications are subject to change without further notice 28Kg (without batteries) 440 x 810 x 132 (3U) EN62040-1-1 EN62040-2 EN62040-3 EN60950-1 IP 20