SPECIFICATION SHEET
MODEL 8140 Fresh Air Ventilator With Powered Damper and Filter
PRODUCT SPECIFICATIONS Overall Dimensions
11.9”H x 14.4”W x 27.8”L
Inlet Collar
6” Round
Outlet Collar
6” Oval
Ventilation Time Dial Setting
Off, 15-60 minutes, (5 min. increments), Test/Reset
Ambiant Temperature
0°F to 160°F
Outdoor Temperature
Setting A, no limit, time only
Limit Settings
“B”, 105°F high limit, 20°F low limit “C”, 100°F high limit, 30°F low limit “D”, 95°F high limit, 40°F low limit
Voltage
115 VAC, 1 phase, 60 Hz
Power
Includes 5’ power cord with 5-15P plug
FEATURES
Ducting
6” diameter flexible insulated duct
Warranty
5 years
• Unit is designed, when properly installed, to achieve ASHRAE Standard 62.2 2010
ETL
Tested to UL Standard 705– Power Ventilators Not For Outdoor Use
• Complies with 2012 & 2015 IECC (2.8 cfm/watt) • Control is integrated into the Ventilator • High and Low Temperature Limit Lock-outs while maintaining ASHRAE 62.2 2010
27.88
• Simple plug-in installation
22.19
• Installation temperature range up to 160°F
14.00
• Intergrated powered damper • Removable, washable filter 11.90
BENEFITS
10.44
• The precise amount of outside air needed in today’s efficiently designed homes is delivered Outlet: Oval Collar for 6" Dia Duct
Inlet: Round Collar for 6" Dia. Duct
• Optimize energy savings by locking out ventilation during hottest/coldest times of the day • Improves indoor air quality • Robust design handles hot attics
10.44
11.90
• Installation labor reduced, requires only a switched outlet and 27.88 24 volt wiring to HVAC system • 22.19 Furnace or air handler does not require an ECM motor 14.00
Outlet: Oval Collar for 6" Dia Duct
THE JOIST
HUNG FROM THE JOIST
When properly installed and set, the Aprilaire Model 8140 Fresh Air Ventilator will meet the mechanical ventilation requirements of: • Energy Star Certified Homes, 11.90 Version 3 • EPA Indoor airPLUS, Version 1 • 2012 International Residential Code (IRC)
14.38
17.19
• 2012 & 2015 International Energy Conservation Code (IECC) Outlet: Inlet: Oval Collar Round Collar • California Energy Commission Title 24 for 6" Dia Duct for 6" Dia. Duct
10.44
TYPICAL ATTIC INSTALLATION Typical Attic Installation Gable End Wall, Band Joist, or Porch Soffit
Return Mixing Box
Fresh Air Intake Duct
Filter
Furnace/Air Handler
Ventilator
FR ES H
AI R
Fresh Air Intake Hood w/ screen
Ventilation Controller
Air Flow
Typical Basement Installation TYPICAL BASEMENT INSTALLATION TYPICAL BASEMENT INSTALLATION
Fresh Air Intake Duct
Fresh Air
Fresh Air Intake Duct Intake Hood
w/ screen
Fresh Air Intake Hood w/ screen
AI R
FR ES H
AI R
Ventilator Ventilation Controller
Mounted To The Joist MOUNTED TO THE JOIST
Power Ventilator
FR
ES
H
Ventilation Controller
Outside Wall
Outside Wall
Air Flow
Air Flow
Filter Filter
Furnace/Air Handler
Furnace/Air Handler
PERFORMANCE
90-2060
Static Pressure* (“w.c.)
Airflow (CFM)
Current (amps)
Power (watts)
Efficacy (CFM/watt)
0.0
285
.4
53
5.39
0.2
250
.4
53
4.70
0.4
195
.4
52
3.75
0.6
130
.4
50
2.62
0.8
25
.4
44
0.52
Mounted To The Wall
AIR FLOW
MOUNTED TO W
* Measured across ventilator.
APRILAIRE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. PO Box 1467 • Madison, WI 53701-1467 • Phone 800/334-6011 • Fax 608/257-4357 • www.aprilairepartners.com Form No. 3042 9.15 264306
©2015 Aprilaire – A division of Research Products Corporation