Preview only show first 10 pages with watermark. For full document please download

Specification T B D - S X D B 1

   EMBED


Share

Transcript

LC SFP BIDI OC-48 ONU XCVR PRODUCT NUMBER: TBD-SxDB1-F11 Specification Small Form Factor Pluggable Simplex LC Receptacle – SFP BIDI ONU - Bidirectional Optical Transceivers STM-16 / OC-48 2488.32Mbit/s Ordering Information T B D - S x D B 1 - F 1 1 Voltage / Temperature 1 : 3.3V / +0 ~ +70 2 : 3.3V / -40 ~ +85 Model Name TBD-S1DB1-F11 Voltage Category Device type Interface 3.3V With DDMI DFB / PIN TBD-S2DB1-F11 Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 AC / AC Coupling SD/LOS LVTTL Temperature Distance Latch Color +0 C~+70 C 10km Blue -40 C~+85 C Version 02 Page 1 LC SFP BIDI OC-48 ONU XCVR PRODUCT NUMBER: TBD-SxDB1-F11 Features ROHS Compliant Standard Small Form Factor Pluggable Package – SFP MSA Compliant Digital Diagnostic SFF-8472 Rev.10.2 Compliant SONET OC-48 IR-1 / SDH STM S-16.1 Compliant IEEE802.3AH 1000BASE-BX10-U Compliant Fibre Channel Standard ( 200-SM-LL-L ) Compliant Laser Class 1 Product – IEC60825-1 Compliant Standard Simplex LC Receptacle Optical Interface Single Fiber and Full Duplex Solution – Integrated WDM Filter Single + 3.3 V Power Supply Differential LVPECL Data Input and Output LVTTL Loss of Signal Serial ID through I2C Interface Low Power Consumption Absolute Maximum Ratings Parameter Symbol Min Typ Max Unit Storage temperature TS -40 -- 85 C Supply voltage VCC 0 -- 4 V -- 5 -- 95 VIN 0 -- VCC V Symbol Min Typ Max Unit VCC 3.1 3.3 3.5 V 0 -- 70 -40 -- 85 -- -- 300 Operating Relative Humidity Input voltage Operating Conditions Parameter Supply Voltage Operating Case temperature ( TBD-S1DB1-F11 ) Operating Case temperature ( TBD-S2DB1-F11 ) Total Current ( Transmitter + Receiver ) Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 Tc Icc ºC mA Version 02 Page 2 LC SFP BIDI OC-48 ONU XCVR PRODUCT NUMBER: TBD-SxDB1-F11 Transmitter Specifications ( VCC=3.1V~3.5V Tc= 0oC~70oC / Tc= -40oC~85oC ) Parameter Symbol Min Typ Max Unit Output Optical Power Pout -8 -- -2 dBm Extinction Ratio ER 9 -- -- dB 1260 1310 1360 nm -- -- 1 nm SMSR 30 -- -- dB Rise/Fall time (20-80%) Tr,f -- -- 160 ps Relative Intensity Noise RIN -- -- -120 dB/Hz Optical Characteristics Center Wavelength C Spectral Width (RMS) Side Mode Suppression Ratio Compliant with ITU-T G.957 Output Eye POFF -- -- -45 dBm Differential Input Voltage VDIFF 0.4 -- 2.0 V Tx_Disable_Input_High VDISH 2.0 -- VCC+0.3 V Tx_Disable_Input_Low VDISL 0 -- 0.8 V Tx_Fault_Output_High VFH 2.0 -- VCC+0.3 V Tx_Fault_Output_Low VFL 0 -- 0.8 V Max. Pout TX-DISABLE Asserted Electrical Characteristics Receiver Specifications ( VCC=3.1V~3.5V Tc= 0oC~70oC / Tc= -40oC~85oC ) Parameter Symbol Min Typ Max Unit PSATIN +0 -- -- dBm PSAN -- -- -18 dBm 1480 -- 1600 nm Optical Characteristics Optical Input Power-maximum Receiver Sensitivity ( PRBS=223-1 BER 10-10 ) Operating Center Wavelength c Optical Return Loss ORL 14 -- -- dB Loss of Signal – De-asserted PLD -- -- -18 dBm Loss of Signal - Asserted PLA -35 -- -- dBm Loss of Signal - Hysteresis PLH 0.5 -- 6 dB Differential Output Voltage VDIFF 0.4 -- 2.0 V Receiver Loss of Signal Output Voltage -Low VLOSL 0 -- 0.8 V Receiver Loss of Signal Output Voltage -High VLOSH 2 -- VCC+0.3 V Electrical Characteristics Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 Version 02 Page 3 LC SFP BIDI OC-48 ONU XCVR PRODUCT NUMBER: TBD-SxDB1-F11 Pin Definition and Descriptions Pin Name Input/Output Level 1 VeeT Input 2 TXFault Output/LVTTL 3 TXDisable Input/LVTTL Description Transmitter ground Laser failure indication. High level indicates “laser failure”. Externally pulled up Transmitter disable, High signal/open disables TX laser output. Low level enables TX output, internally pulled up. Module definition 2, SDA, Data line for I2C bus. Externally pulled up 4 MOD-DEF(2) Input/output 5 MOD-DEF(1) Input Module definition 1, SCL, Clock for I2C bus. Externally pulled up 6 MOD-DEF(0) Output Module definition 0, Module present. Ground inside module. 7 Rate Select - No connection. 8 LOS Output/LVTTL Receiver loss of signal indication. Low signal indicates optical signal is present at RX input. Should be Externally pulled up. 9 VeeR Input Receiver ground 10 VeeR Input Receiver ground 11 VeeR Input Receiver ground 12 RD - Output/CML Inverted receiver data output (AC coupled) 13 RD + Output/CML Non-inverted receiver data output (AC coupled) 14 VeeR Input Receiver ground 15 VccR Input Receiver power supply 16 VccT Input Transmitter power supply 17 VeeT Input Transmitter ground 18 TD + Input/LVPECL Non-inverted transmitter data input (AC coupled) 19 TD - Input/LVPECL Inverted transmitter data input (AC coupled) 20 VeeT Input Transmitter ground Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 Version 02 Page 4 LC SFP BIDI OC-48 ONU XCVR PRODUCT NUMBER: TBD-SxDB1-F11 Recommended Circuit Diagram Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 Version 02 Page 5 LC SFP BIDI OC-48 ONU XCVR PRODUCT NUMBER: TBD-SxDB1-F11 Content in 2-Wire Address A0H Address 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 ~ 35 36 37 ~ 39 40 ~ 55 56 ~ 59 60 ~ 61 62 63 64 65 66 67 68 ~ 83 84 ~ 89 90 ~ 91 92 93 94 95 96~127 HEX 03 04 07 00 12 00 00 00 00 00 00 03 19 00 14 C8 00 00 00 00 46,4F,52,4D,45,52,49,43 ,41,4F,45,20,20,20,20,20 00 00,00,00 54,42,44,2D,53,31(32),44,42 ,31,2D,46,31,31,20,20,20 00,00,00,00 05,1E 00 00 1A 00 00 Serial Number yy/mm/dd 20,20 68 B0 03 Name of Field Identifier Extended Identifier Connector type Infiniband Compliance Codes SONET Compliance Codes SONET Compliance Codes Ethernet Compliance Codes Fiber Channel link length Fiber Channel transmitter technology Fiber Channel transmission media Fiber Channel speed Encoding codes: Nominal Bit Rate (units of 100Mbps) Rate identifier Link length supported for 9um fiber Link length supported for 9um fiber Link length supported for 50um,OM2 Link length supported for 62.5um,OM1 Link length supported for copper Link length supported for 50um,OM3 Description SFP SFP LC Not compliant SONET IR-1 compliant OC-48, single mode,inter reach Not compliant Not compliant Not compliant Not compliant Not compliant NRZ 2488Mbps Unspecified 20 (units of km) 200 (units of 100m) N/A (units of 10m) N/A(units of 10m) N/A (units of 1m) N/A (units of 10m) Vendor Name Unallocated Vendor OUI FORMERICAOE Part Number Vendor Revision number Laser Wavelength Unallocated CC_BASE: Options Options Bit Rate, max. Bit Rate, min. Serial Number Date Code Vendor specific lot code Diagnostic Monitoring Type Enhanced Options (soft) SFF-8472 Compliance CC_EXT Vendor specific TBD-S1(2)DB1-F11 Unspecified 1310nm Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 Unspecified Check sum of byte 0 ~ 62 TX-DIS, TX_FAULT, RX-LOS Unspecified Unspecified Unspecified Internal calibration All flags, TX_FAULT, RX-LOS Rev10.2 Check sum of byte 64 ~ 94 Version 02 Page 6 LC SFP BIDI OC-48 ONU XCVR PRODUCT NUMBER: TBD-SxDB1-F11 Content in 2-Wire Address A2H Add Bytes Name Hex 00-01 02-03 04-05 06-07 08-09 10-11 12-13 14-15 16-17 18-19 20-21 22-23 24-25 26-27 28-29 30-31 32-33 34-35 36-37 38-39 40-55 56-59 60-63 64-67 68-71 72-75 76-77 78-79 80-81 82-83 84-85 86-87 88-89 90-91 92-94 95 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 16 4 4 4 4 4 2 2 2 2 2 2 2 2 3 1 Temp High Alarm* Temp Low Alarm* Temp High Warning* Temp Low Warning* Voltage High Alarm Voltage Low Alarm Voltage High Warning Voltage Low Warning Bias High Alarm Bias Low Alarm Bias High Warning Bias Low Warning TX Power High Alarm TX Power Low Alarm TX Power High Warning TX Power Low Warning RX Power High Alarm RX Power Low Alarm RX Power High Warning RX Power Low Warning Reserved RX_PWR(4) RX_PWR(3) RX_PWR(2) RX_PWR(1) RX_PWR(0) TX_I(Slope) TX_I(Offset) TX_PWR(Slope) TX_PWR(Offset) T(Slope) T(Offset) V(Slope) V(Offset) Reserved Checksum 5500 (6400) 0000 (D800) 5000 (5F00) 0A00 (E200) 8CA0 7530 88B8 7918 AFC8 09C4 9C40 0DAC 312D 031A 1F07 04EB 3DE9 0064 2710 009E 00 00000000 00000000 00000000 3F800000 00000000 0100 0000 0100 0000 0100 0000 0100 0000 00 Real Value 85 (100 0 (-40 80 (95 10 (-30 3.6V 3.0V 3.5V 3.1V 90mA 5mA 80mA 7mA 1dBm -11dBm -1dBm -9dBm 2dBm -20dBm 0dBm -18dBm 0 0 0 1 0 1 0 1 0 1 0 1 0 - ) ) ) ) Note *: ( ) for TBD-S2DB1-F11. Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 Version 02 Page 7 LC SFP BIDI OC-48 ONU XCVR PRODUCT NUMBER: TBD-SxDB1-F11 Mechanical Outlines ( Unit : mm) Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 Version 02 Page 8