LC SFP BIDI OC-48 ONU XCVR PRODUCT NUMBER: TBD-SxDB1-F11
Specification Small Form Factor Pluggable Simplex LC Receptacle – SFP BIDI ONU - Bidirectional Optical Transceivers STM-16 / OC-48 2488.32Mbit/s
Ordering Information
T B D - S x D B 1 - F 1 1
Voltage / Temperature 1 : 3.3V / +0 ~ +70 2 : 3.3V / -40 ~ +85
Model Name TBD-S1DB1-F11
Voltage Category Device type Interface 3.3V
With DDMI
DFB / PIN
TBD-S2DB1-F11
Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118
AC / AC Coupling
SD/LOS LVTTL
Temperature Distance Latch Color +0 C~+70 C
10km
Blue
-40 C~+85 C
Version 02
Page
1
LC SFP BIDI OC-48 ONU XCVR PRODUCT NUMBER: TBD-SxDB1-F11 Features ROHS Compliant Standard Small Form Factor Pluggable Package – SFP MSA Compliant Digital Diagnostic SFF-8472 Rev.10.2 Compliant SONET OC-48 IR-1 / SDH STM S-16.1 Compliant IEEE802.3AH 1000BASE-BX10-U Compliant Fibre Channel Standard ( 200-SM-LL-L ) Compliant Laser Class 1 Product – IEC60825-1 Compliant Standard Simplex LC Receptacle Optical Interface Single Fiber and Full Duplex Solution – Integrated WDM Filter Single + 3.3 V Power Supply Differential LVPECL Data Input and Output LVTTL Loss of Signal Serial ID through I2C Interface Low Power Consumption
Absolute Maximum Ratings Parameter
Symbol
Min
Typ
Max
Unit
Storage temperature
TS
-40
--
85
C
Supply voltage
VCC
0
--
4
V
--
5
--
95
VIN
0
--
VCC
V
Symbol
Min
Typ
Max
Unit
VCC
3.1
3.3
3.5
V
0
--
70
-40
--
85
--
--
300
Operating Relative Humidity Input voltage
Operating Conditions Parameter Supply Voltage Operating Case temperature ( TBD-S1DB1-F11 ) Operating Case temperature ( TBD-S2DB1-F11 ) Total Current ( Transmitter + Receiver )
Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118
Tc Icc
ºC mA
Version 02
Page
2
LC SFP BIDI OC-48 ONU XCVR PRODUCT NUMBER: TBD-SxDB1-F11 Transmitter Specifications ( VCC=3.1V~3.5V Tc= 0oC~70oC / Tc= -40oC~85oC ) Parameter
Symbol
Min
Typ
Max
Unit
Output Optical Power
Pout
-8
--
-2
dBm
Extinction Ratio
ER
9
--
--
dB
1260
1310
1360
nm
--
--
1
nm
SMSR
30
--
--
dB
Rise/Fall time (20-80%)
Tr,f
--
--
160
ps
Relative Intensity Noise
RIN
--
--
-120
dB/Hz
Optical Characteristics
Center Wavelength
C
Spectral Width (RMS) Side Mode Suppression Ratio
Compliant with ITU-T G.957
Output Eye POFF
--
--
-45
dBm
Differential Input Voltage
VDIFF
0.4
--
2.0
V
Tx_Disable_Input_High
VDISH
2.0
--
VCC+0.3
V
Tx_Disable_Input_Low
VDISL
0
--
0.8
V
Tx_Fault_Output_High
VFH
2.0
--
VCC+0.3
V
Tx_Fault_Output_Low
VFL
0
--
0.8
V
Max. Pout TX-DISABLE Asserted Electrical Characteristics
Receiver Specifications ( VCC=3.1V~3.5V Tc= 0oC~70oC / Tc= -40oC~85oC ) Parameter
Symbol
Min
Typ
Max
Unit
PSATIN
+0
--
--
dBm
PSAN
--
--
-18
dBm
1480
--
1600
nm
Optical Characteristics Optical Input Power-maximum Receiver Sensitivity ( PRBS=223-1
BER
10-10 )
Operating Center Wavelength
c
Optical Return Loss
ORL
14
--
--
dB
Loss of Signal – De-asserted
PLD
--
--
-18
dBm
Loss of Signal - Asserted
PLA
-35
--
--
dBm
Loss of Signal - Hysteresis
PLH
0.5
--
6
dB
Differential Output Voltage
VDIFF
0.4
--
2.0
V
Receiver Loss of Signal Output Voltage -Low
VLOSL
0
--
0.8
V
Receiver Loss of Signal Output Voltage -High
VLOSH
2
--
VCC+0.3
V
Electrical Characteristics
Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118
Version 02
Page
3
LC SFP BIDI OC-48 ONU XCVR PRODUCT NUMBER: TBD-SxDB1-F11 Pin Definition and Descriptions
Pin
Name
Input/Output Level
1
VeeT
Input
2
TXFault
Output/LVTTL
3
TXDisable
Input/LVTTL
Description Transmitter ground Laser failure indication. High level indicates “laser failure”. Externally pulled up Transmitter disable, High signal/open disables TX laser output. Low level enables TX output, internally pulled up. Module definition 2, SDA, Data line for I2C bus. Externally pulled up
4
MOD-DEF(2) Input/output
5
MOD-DEF(1) Input
Module definition 1, SCL, Clock for I2C bus. Externally pulled up
6
MOD-DEF(0) Output
Module definition 0, Module present. Ground inside module.
7
Rate Select
-
No connection.
8
LOS
Output/LVTTL
Receiver loss of signal indication. Low signal indicates optical signal is present at RX input. Should be Externally pulled up.
9
VeeR
Input
Receiver ground
10
VeeR
Input
Receiver ground
11
VeeR
Input
Receiver ground
12
RD -
Output/CML
Inverted receiver data output (AC coupled)
13
RD +
Output/CML
Non-inverted receiver data output (AC coupled)
14
VeeR
Input
Receiver ground
15
VccR
Input
Receiver power supply
16
VccT
Input
Transmitter power supply
17
VeeT
Input
Transmitter ground
18
TD +
Input/LVPECL
Non-inverted transmitter data input (AC coupled)
19
TD -
Input/LVPECL
Inverted transmitter data input (AC coupled)
20
VeeT
Input
Transmitter ground
Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118
Version 02
Page
4
LC SFP BIDI OC-48 ONU XCVR PRODUCT NUMBER: TBD-SxDB1-F11 Recommended Circuit Diagram
Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118
Version 02
Page
5
LC SFP BIDI OC-48 ONU XCVR PRODUCT NUMBER: TBD-SxDB1-F11 Content in 2-Wire Address A0H Address 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 ~ 35 36 37 ~ 39 40 ~ 55 56 ~ 59 60 ~ 61 62 63 64 65 66 67 68 ~ 83 84 ~ 89 90 ~ 91 92 93 94 95 96~127
HEX 03 04 07 00 12 00 00 00 00 00 00 03 19 00 14 C8 00 00 00 00 46,4F,52,4D,45,52,49,43 ,41,4F,45,20,20,20,20,20 00 00,00,00 54,42,44,2D,53,31(32),44,42 ,31,2D,46,31,31,20,20,20 00,00,00,00 05,1E 00 00 1A 00 00 Serial Number yy/mm/dd 20,20 68 B0 03
Name of Field Identifier Extended Identifier Connector type Infiniband Compliance Codes SONET Compliance Codes SONET Compliance Codes Ethernet Compliance Codes Fiber Channel link length Fiber Channel transmitter technology Fiber Channel transmission media Fiber Channel speed Encoding codes: Nominal Bit Rate (units of 100Mbps) Rate identifier Link length supported for 9um fiber Link length supported for 9um fiber Link length supported for 50um,OM2 Link length supported for 62.5um,OM1 Link length supported for copper Link length supported for 50um,OM3
Description SFP SFP LC Not compliant SONET IR-1 compliant OC-48, single mode,inter reach Not compliant Not compliant Not compliant Not compliant Not compliant NRZ 2488Mbps Unspecified 20 (units of km) 200 (units of 100m) N/A (units of 10m) N/A(units of 10m) N/A (units of 1m) N/A (units of 10m)
Vendor Name Unallocated Vendor OUI
FORMERICAOE
Part Number Vendor Revision number Laser Wavelength Unallocated CC_BASE: Options Options Bit Rate, max. Bit Rate, min. Serial Number Date Code Vendor specific lot code Diagnostic Monitoring Type Enhanced Options (soft) SFF-8472 Compliance CC_EXT Vendor specific
TBD-S1(2)DB1-F11 Unspecified 1310nm
Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118
Unspecified
Check sum of byte 0 ~ 62 TX-DIS, TX_FAULT, RX-LOS Unspecified Unspecified
Unspecified Internal calibration All flags, TX_FAULT, RX-LOS Rev10.2 Check sum of byte 64 ~ 94
Version 02
Page
6
LC SFP BIDI OC-48 ONU XCVR PRODUCT NUMBER: TBD-SxDB1-F11 Content in 2-Wire Address A2H Add
Bytes
Name
Hex
00-01 02-03 04-05 06-07 08-09 10-11 12-13 14-15 16-17 18-19 20-21 22-23 24-25 26-27 28-29 30-31 32-33 34-35 36-37 38-39 40-55 56-59 60-63 64-67 68-71 72-75 76-77 78-79 80-81 82-83 84-85 86-87 88-89 90-91 92-94 95
2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 16 4 4 4 4 4 2 2 2 2 2 2 2 2 3 1
Temp High Alarm* Temp Low Alarm* Temp High Warning* Temp Low Warning* Voltage High Alarm Voltage Low Alarm Voltage High Warning Voltage Low Warning Bias High Alarm Bias Low Alarm Bias High Warning Bias Low Warning TX Power High Alarm TX Power Low Alarm TX Power High Warning TX Power Low Warning RX Power High Alarm RX Power Low Alarm RX Power High Warning RX Power Low Warning Reserved RX_PWR(4) RX_PWR(3) RX_PWR(2) RX_PWR(1) RX_PWR(0) TX_I(Slope) TX_I(Offset) TX_PWR(Slope) TX_PWR(Offset) T(Slope) T(Offset) V(Slope) V(Offset) Reserved Checksum
5500 (6400) 0000 (D800) 5000 (5F00) 0A00 (E200) 8CA0 7530 88B8 7918 AFC8 09C4 9C40 0DAC 312D 031A 1F07 04EB 3DE9 0064 2710 009E 00 00000000 00000000 00000000 3F800000 00000000 0100 0000 0100 0000 0100 0000 0100 0000 00
Real Value
85 (100 0 (-40 80 (95 10 (-30 3.6V 3.0V 3.5V 3.1V 90mA 5mA 80mA 7mA 1dBm -11dBm -1dBm -9dBm 2dBm -20dBm 0dBm -18dBm 0 0 0 1 0 1 0 1 0 1 0 1 0 -
) ) ) )
Note *: ( ) for TBD-S2DB1-F11.
Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118
Version 02
Page
7
LC SFP BIDI OC-48 ONU XCVR PRODUCT NUMBER: TBD-SxDB1-F11 Mechanical Outlines ( Unit : mm)
Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118
Version 02
Page
8