Preview only show first 10 pages with watermark. For full document please download

Specification Topv Mini 5

   EMBED


Share

Transcript

TOP V Mini 5-6K UPS Features: • True online double conversion technology • Very wide input voltage range (110VAC-300VAC) • High input power factor • Automatic bypass system • Generator compatible • Overall efficiency 90% • Smart Charger for efficient charging and extending battery life • Includes 6 built in outlets • Easy to use LCD display for alarm control • The UPS includes smart software solutions for shutdown of computers and network servers with SNMP option • Very small physical dimensions require little floor space • Built in isolation transformer (in model TOP VM 5K) Specifications Model Capacity Isolation transformer Input Voltage Range Top VM 5K 5000VA Built in Low line transfer Top VM 6K 6000VA Not optional 175VAC / 150VAC /130VAC /110VAC ± 5% (Based on load percentage 100%- 80% / 80%-70% / 70-60% / 60%-0) Low line comeback 183VAC / 158VAC /138VAC /118VAC ± 5% (Based on load percentage 100%- 80% / 80%-70% / 70-60% / 60%-0) Low line comeback (Auto restart) High line transfer High line comeback Frequency Range Phase Power factor (nominal output @ full load) Output Output voltage AC voltage regulation (Batt.mode) Frequency range (synchronized range) Frequency range (Batt.mode) Current crest ratio Harmonic distortion Transfer Time AC mode to batt. Mode Inverter to bypass Wave form (Batt. Mode) Efficiency AC mode (@100% RCD load) Battery Battery type Charging current (max) Charging voltage Indicators LCD panel Alarm Battery mode Low battery Overload Fault Physical Dimension DxWxH (mm) Net weight (kgs) Environment Humidity Noise level Management Communication 183VAC ± 5% (80% ~100% LOAD), 158VAC ± 5% (0% ~80% LOAD) 280 VAC ±5% 270 VAC ±5% 40 ~ 70 Hz (Auto sensing) Single phase with ground =>0.95 208 / 220 /230 /240 VAC ± 3% 47 ~ 53 Hz or 57 ~ 63 Hz 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz 3:1 =< 3% THD (Linear load) =< 6% THD (Non linear load) Zero 4 ms (typical) Pure sine wave 90% Maintenance free lead acid batteries - 12V/10AH 1.0 A 109.4 VDC ±1% UPS status, load level, battery level, input/output voltage, discharge timer and fault conditions Sounding every 4 seconds Sounding every second Sounding twice every second Continuously sounding 426 x 190 x 448 62.5 426 x 190 x 318 35.3 20 – 90 % RH @ 0-40ºC (non- condensing) Less than 55Db @ 1 meter RS232 Card / optional USB card, SNMP card or AS400 card available Support windows 2000/2003/XP/Vista/2008, Windows 7, Linux, Unix and MAC * Product specifications are subject to change without further notice