C18 Series Photoelectric Sensors M18 (18 mm) metal – DC
• 36 models available • Diffuse, Polarized reflective, Through-beam, and Diffuse with background suppression models • Long operating distances • Scratch resistant and easy-to-clean glass lens • Adustable sensitivity (diffuse models only) • Axial cable or 12 mm quick-disconnect models • Complete overload protection • IP67 rated
C18 Series Photoelectric Sensor Selection Chart Part Number
Price Sensing Range Output State
Optics
Logic
Connection
Wiring Dimensions
Diffuse 1 N.O. and 1 N.C. Axial NPN 2 m (6.5’) axial cable C18D-0N-1A $41.00 1 N.O. and 1 N.C.. Axial PNP 2 m (6.5’) axial cable C18D-0P-1A $41.00 1 N.O. and 1 N.C. Axial NPN M12 (12 mm) connector C18D-0N-1E $41.00 1 N.O. and 1 N.C. Axial PNP M12 (12 mm) connector C18D-0P-1E $41.00 Up to 600 mm (23.62 in) 1 N.O. and 1 N.C.. Right-angle NPN 2 m (6.5’) axial cable C18D-0N-2A $36.25 1 N.O. and 1 N.C. Right-angle PNP 2 m (6.5’) axial cable C18D-0P-2A $54.00 1 N.O. and 1 N.C. Right-angle NPN M12 (12 mm) connector C18D-0N-2E $54.00 1 N.O. and 1 N.C.. Right-angle PNP M12 (12 mm) connector C18D-0P-2E $54.00 Diffuse with background suppression Axial NPN 2 m (6.5’) axial cable C18B-AN-1A $67.00 Axial PNP 2 m (6.5’) axial cable C18B-AP-1A $67.00 10-120 mm N..O. (0.39 to 4.72 in) Axial NPN M12 (12 mm) connector C18B-AN-1E $67.00 Axial PNP M12 (12 mm) connector C18B-AP-1E $67.00 Right-angle NPN 2 m (6.5’) axial cable C18B-AN-2A $71.75 Right-angle PNP 2 m (6.5’) axial cable C18B-AP-2A $104.00 10-120 mm N.O. (0.39 to 4.72 in) Right-angle NPN M12 (12 mm) connector C18B-AN-2E $71.75 Right-angle PNP M12 (12 mm) connector C18B-AP-2E $104.00 Polarized reflective *Purchase reflectors separately. Axial NPN 2 m (6.5’) axial cable C18P-AN-1A $43.50 Axial PNP 2 m (6.5’) axial cable C18P-AP-1A $43.50 Up to 2 m N.O. (6.6 ft) Axial NPN M12 (12 mm) connector C18P-AN-1E $43.50 Axial PNP M12 (12 mm) connector C18P-AP-1E $43.50 Right-angle NPN 2 m (6.5’) axial cable C18P-AN-2A $57.00 Right-angle PNP 2 m (6.5’) axial cable C18P-AP-2A $57.00 Up to 2 m N.O. (6.6 ft) Right-angle NPN M12 (12 mm) connector C18P-AN-2E $57.00 Right-angle PNP M12 (12 mm) connector C18P-AP-2E $57.00 Through-beam **Purchase one receiver and one emitter for a complete set. Axial NPN 2 m (6.5’) axial cable C18R-0N-1A $38.00 Axial PNP 2 m (6.5’) axial cable C18R-0P-1A $38.00 Up to 6 m 1 N.O. and 1 N.C. (19.7 ft) Axial NPN M12 (12 mm) connector C18R-0N-1E $38.00 Axial PNP M12 (12 mm) connector C18R-0P-1E $38.00 $28.00 Axial 2 m (6.5’) axial cable C18E-00-1A Receiver Receiver dependent Receiver dependent dependent M12 (12 mm) connector $28.00 Axial C18E-00-1E Right-angle NPN 2 m (6.5’) axial cable C18R-0N-2A $50.00 Right-angle PNP 2 m (6.5’) axial cable C18R-0P-2A $50.00 Up to 6 m 1 N.O. and 1 N.C. (19.7 ft.) Right-angle NPN M12 (12 mm) connector C18R-0N-2E $50.00 Right-angle PNP M12 (12 mm) connector C18R-0P-2E $41.00 $38.00 Right-angle 2 m (6.5’) axial cable C18E-00-2A Receiver Receiver dependent Receiver dependent $38.00 Right-angle dependent M12 (12 mm) connector C18E-00-2E
www.automationdirect.com/photoelectric
Characteristic Curves
Diagram 3
Figure 1
Chart 5
Diagram 4
Figure 1
Chart 5
Diagram 3
Figure 2
Chart 5
Diagram 4
Figure 2
Chart 5
Diagram 3
Figure 3
Chart 6
Diagram 4
Figure 3
Chart 6
Diagram 3
Figure 4
Chart 6
Diagram 4
Figure 4
Chart 6
Diagram 1
Figure 1
Chart 1
Diagram 2
Figure 1
Chart 1
Diagram 1
Figure 2
Chart 1
Diagram 2
Figure 2
Chart 1
Diagram 1
Figure 3
Chart 2
Diagram 2
Figure 3
Chart 2
Diagram 1
Figure 4
Chart 2
Diagram 2
Figure 4
Chart 2
Diagram 1
Figure 1
Chart 3
Diagram 2
Figure 1
Chart 3
Diagram 1
Figure 2
Chart 3
Diagram 2
Figure 2
Chart 3
Diagram 1
Figure 3
Chart 4
Diagram 2
Figure 3
Chart 4
Diagram 1
Figure 4
Chart 4
Diagram 2
Figure 4
Chart 4
Diagram 3
Figure 1
Chart 7
Diagram 4
Figure 1
Chart 7
Diagram 3
Figure 2
Chart 7
Diagram 4
Figure 2
Chart 7
Diagram 5
Figure 5
Chart 7
Diagram 5
Figure 6
Chart 7
Diagram 3
Figure 3
Chart 8
Diagram 4
Figure 3
Chart 8
Diagram 3
Figure 4
Chart 8
Diagram 4
Figure 4
Chart 8
Diagram 5
Figure 7
Chart 8
Diagram 5
Figure 8
Chart 8
Photoelectric Sensors
tPHS-45
For the latest prices, please check AutomationDirect.com.
C18 Series Photoelectric Sensors Specifications
Diffuse Models
Type Sensing Distance Emission Light Spot Diameter Sensitivity
Diffuse
Through-beam1
Diffuse with background suppression 10 to 120 mm (0.39 to 4.72 in)3
Polarized reflection
600 mm (23.62in)2
2 m (6.6 ft)
6 m (19.7 ft)
LED red (660nm)
LED red (660nm)
LED red polarized (660 nm)
LED red (660nm)
See charts
–
Adjustable one-turn pot.
Output Type
Through-beam Models
Diffuse Models with Background Suppression Reflective Models
NPN or PNP; 1 L.O. and 1 D.O.
NPN or PNP; L.O. only
20 mA
25 mA
Operating Voltage
NPN or PNP; D.O. only
NPN or PNP; 1 L.O. and 1 D.O.
10-36 VDC
No Load Supply Current Operating (Load) Current Off-state (Leakage) Current Voltage Drop Switching Frequency Ripple Time Delay Before Availability (tv) Short-Circuit Protection Operating Temperature Range Protection Degree (DIN 40050) LED Indicators - Switching Status Housing Material Lens Material Shock/Vibration Tightening Torque Weight Connectors Agency Approvals
15 mA
Receiver: 10 mA Emitter:15 mA
1kHz
1kHz
20ms
20ms
m200 mA m10µ A m2.0 V 1kHz
500Hz m20%
60ms
20ms
Yes (switch autoresets after overload is removed) -25° to + 55°C (-13° to 131°F) IEC IP67 Yellow (output state, output energized), green (excess light indication). Emitter has no LED Chrome-plated brass Glass See terminology section 50 Nm (36.88 lb-ft) 65.22 g (2.3 oz). 2m (6.5’) axial cable; M12 (12mm) connector UL file E328811
Notes: 1Through-beam sensors must be used in pairs consisting of one receiver and one emitter. 2With 200x200mm white matte paper. 3With 100x100mm white matte paper.
Wiring diagrams
Warning: These products are not safety sensors and are not suitable for use in personal safety applications.
Diagram 1 NPN Output
Diagram 2 Connector
PNP Output
M12 Connector
Diagram 3 4-Wire NPN Output
Diagram 4 4-Wire PNP Output
Diagram 5 Emitter
Switching Element Function Emitter test input (<4V: OFF / >8V or open: ON) 0.5mA
tPHS-46
Photoelectric Sensors
Thru-beam and Reflective Models Diffuse Models Light on N.C. Dark on N.O.
N.O. N.C.
1-800-633-0405
For the latest prices, please check AutomationDirect.com.
C18 Series Photoelectric Sensors Dimensions (mm)
Figure 2 1.14 (29)
0.16 (4)
Potentiometer (Diffuse models only)
Dia. 0.18 (4.5)
Figure 3
2.5 (63.5) 0.32 (8)
0.51 (13)
Potentiometer (diffuse models only)
0.34 (8.5)
0.31 (7.8)
0.31 (7.8)
1.97 (50)
1.14 (29)
0.16 (4)
Figure 1
Figure 4 0.15 (3.9)
0.34 (8.5)
Potentiometer (Diffuse models only)
Potentiometer (Diffuse models only)
Dia. 0.18 (4.5)
2.95 (75)
0.31 (7.8)
0.32 (8)
2.42 (61.5)
0.16 (4)
1.56 (39.5)
1.56 (39.5)
2.42 (61.5)
0.15 (3.9)
Dia. 0.65 (16.6)
Figure 5
Figure 6 2.5 (63.5)
1.97 (50)
0.7(16.4)
0.2 (5)
0.32 (8)
0.16 (4)
Figure 8
C18E-00-1A LLK-1180-000
2.95 (75) SW24
SW24
2.42 (61.5)
C18E-00-2A LLK-1180W-000
www.automationdirect.com/photoelectric
0.5 (13)
C18E-00-1E LLS-1180-000
0.32 (8)
Ø 0.67 (16.9)
M12x1
(4.5)
0.16 (4)
Ø 0.18
0.34 (8.5)
M18x1
0.15 (3.9)
Figure 7
0.34 (8.5)
0.16 (4)
0.34 (8.5)
2.42 (61.5)
0.32 0.53 (8) (13.5)
Note: Dimensions are in inches (millimeters).
C18E-00-2E LLS-1180W-000
Photoelectric Sensors
tPHS-47
For the latest prices, please check AutomationDirect.com.
C18 Series Photoelectric Sensors Characteristic Curves Chart 1 (Diffuse with background suppression C18B-*--1*) s
Chart 2 (Diffuse with Background Suppression C18B-*-2*)
[mm]
s
140
140
120
120
100
100
80
a
80
60
s
40
a
60
s
40
20
a [mm]
[mm]
20 6
4
0
2
2
4
a [mm]
6
Chart 3 (Polarized reflective C18P-*-1*)
Chart 5 (Diffuse c18D-*-1* s
6
4
2
0
2
4
6
Chart 4 (Polarized reflective C18P-*-2*)
Chart 6 (Diffuse c18D-*-2*)
[mm]
700 600 500 a
400 300
s
200 100
a
[mm]
80
0
40
40
80
* typical values
Chart 7 (Through-beam C18R-*-1*) s
Chart 8 (Through-beam C18R-*-2*) s
[mm]
28000
[mm]
28000
24000
24000
20000
20000
16000
s
16000
a
12000
12000
8000
a
8000 4000
a [mm]
300
0
300
a [mm]
tPHS-48
s
4000
Photoelectric Sensors
300
0
300
1-800-633-0405
Prices as of June 29, 2016. Check Web site for most current prices.
Sensor Cables and Connectors Cables with quick-disconnect plugs
• PVC (polyvinyl chloride) jacket for typical industrial applications • PUR (polyurethane) jacket for oily and direct sunlight applications • IP67 rated
• Industry standard axial and right-angle M8/M12 screw-lock connectors with open leads. The cables listed can be used with patch cables • 2m, 3m, 5m, 7m, 10m and 15m cable lengths
CD08-0A-020-C1 and -A1 shown
M8 Quick-Disconnect Cables (Pico, Nano) Part Number Price M8 Quick-Disconnects $8.25 CD08-0A-020-A1 $8.25 CD08-0A-020-C1 $10.50 CD08-0A-050-A1 $11.25 CD08-0C-050-A1 $10.50 CD08-0A-050-C1 $11.25 CD08-0C-050-C1 $13.00 CD08-0A-070-A1 $13.00 CD08-0A-070-C1
Length
Poles
Connector
Jacket
Dimensions
2m (6.5 ft.)
3
Axial female
PVC
Figure 1
CD08-0A-050-C1 and -A1 shown 2m (6.5 ft.)
3
Right-angle female
PVC
Figure 2
5m (16.4 ft.)
3
Axial female
PVC
Figure 4
5m (16.4 ft.)
3
Axial female
PUR
Figure 3
5m (16.4 ft.)
3
Right-angle female
PVC
Figure 5
5m (16.4 ft.)
3
Right-angle female
PUR
Figure 5
7m (23 ft.)
3
Axial female
PVC
Figure 1
7m (23 ft.)
3
Right-angle female
PVC
Figure 2
CD12L-0B-020-A0 and -C0 shown
M12 Quick-Disconnect Cables (Euro, Micro DC-Single Key) Part Number Price M12 Quick-Disconnects $10.50 CD12M-0B-050-A1* $12.50 CD12M-0D-050-A1* $10.50 CD12M-0B-050-C1* $12.50 CD12M-0D-050-C1* $8.25 CD12L-0B-020-A0 $8.25 CD12L-0B-020-C0 $13.00 CD12M-0B-070-A1 $13.00 CD12M-0B-070-C1 7000-12221-2141000 $15.00 7000-12221-2141500 $20.00 7000-12341-2141000 $15.00 7000-12341-2141500 $20.00 7000-12241-2150300 $9.50 7000-12241-2150500 $12.00 7000-12241-2151000 $18.00 7000-12361-2150300 $9.50 7000-12361-2150500 $12.00 7000-12361-2151000 $18.00 7000-17041-2950300 $22.00 7000-17041-2950500 $27.00 7000-17041-2951000 $42.00 7000-17061-2950300 $22.00 7000-17061-2950500 $27.00 7000-17061-2951000 $42.00 7000-19041-7050300 $34.00 7000-19041-7050500 $41.00 7000-19041-7051000 $60.00 7000-19061-7050300 $34.00 7000-19061-7050500 $41.00 7000-19061-7051000 $60.00
Length
Poles
Connector
Jacket Dimensions
5m (16.4 ft)
3
Axial female
PVC
5m (16.4 ft)
3
Axial female
PUR
Figure 9
5m (16.4 ft)
3
Right-angle female
PVC
Figure 10
5m (16.4 ft)
3
Right-angle female
PUR
Figure 11
2m (6.5 ft)
4
Axial female
PVC
Figure 6
2m (6.5 ft)
4
Right-angle female
PVC
Figure 7
7m (23 ft)
4
Axial female
PVC
Figure 6
7m (23 ft)
4
Right-angle female
PVC
Figure 7
10m (32.8 ft) 15m (49.2 ft) 10m (32.8 ft)
4 4 4
Axial female Axial female Right-angle female
PVC PVC PVC
Figure 13 Figure 13 Figure 14
15m (49.2 ft)
4
Right-angle female
PVC
Figure 14
3m (9.8 ft)
5
Axial female
PVC
Figure 15
5m (16.4 ft)
5
Axial female
PVC
Figure 15
10m (32.8 ft)
5
Axial female
PVC
Figure 15
3m (9.8 ft)
5
Right-angle female
PVC
Figure 16
5m (16.4 ft)
5
Right-angle female
PVC
Figure 16
10m (32.8 ft) 3m (9.8 ft) 5m (16.4 ft)
5 8 8
Right-angle female Axial female Axial female
PVC PUR PUR
Figure 16 Figure 17 Figure 17
10m (32.8 ft)
8
Axial female
PUR
Figure 17
3m (9.8 ft)
8
Right-angle female
PUR
Figure 18
5m (16.4 ft)
8
Right-angle female
PUR
Figure 18
10m (32.8 ft)
8
Right-angle female
PUR
Figure 18
Figure 8
3m (9.8 ft)
12
Axial female
PUR
Figure 19
5m (16.4 ft)
12
Axial female
PUR
Figure 19
10m (32.8 ft)
12
Axial female
PUR
Figure 19
3m (9.8 ft)
12
Right-angle female
PUR
Figure 20
5m (16.4 ft)
12
Right-angle female
PUR
Figure 20
10m (32.8 ft)
12
Right-angle female
PUR
Figure 20
* Note: Do not use with sensors that require 4-pole cables.
CD12M-0B-050-C1 and -A1 shown
7000-12221-2141000
7000-12241-2150500
7000-17041-2951000
7000-19041-7050500 Book 3 (14.3)
w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s
Sensor Cables and Connectors
eWD-69
Prices as of June 29, 2016. Check Web site for most current prices.
Sensor Cables and Connectors Shielded M12 Cables with quick-disconnect plugs • Industry standard axial and right-angle M12 screw-lock connectors with open leads • Braided shield located inside the cord jacket and connected to the coupling nut
• 5m and 10m cable lengths • PUR (polyurethane) jacket for oily and direct sunlight applications • IP67 rated
Shielded M12 Quick-Disconnect Cables (Euro, Micro DC-Single Key) Part Number
Price Length
M12 Quick-Disconnects (shielded) 7000-13201-3310500 $19.00 5m (16.4 ft) 7000-13201-3311000 $29.00 10m (32.8 ft) 7000-13261-3310500 $19.00 5m (16.4 ft) 7000-13261-3311000 $29.00 10m (32.8 ft) 7000-13221-3490500 $22.00 5m (16.4 ft) 7000-13221-3491000 $34.00 10m (32.8 ft) 7000-13281-3490500 $22.00 5m (16.4 ft) 7000-13281-3491000 $34.00 10m (32.8 ft) 7000-17121-2940500 $36.00 5m (16.4 ft) 7000-17121-2941000 $55.00 10m (32.8 ft) 7000-17141-2940500 $36.00 5m (16.4 ft) 7000-17141-2941000 $55.00 10m (32.8 ft)
7000-17121-2941000
7000-17141-2940500
Poles
Connector
Jacket Dimensions
4
Axial female
PUR
Figure 21
4
Axial female
PUR
Figure 21
4
Right-angle female
PUR
Figure 22
4
Right-angle female
PUR
Figure 22
5
Axial female
PUR
Figure 23
5
Axial female
PUR
Figure 23
5
Right-angle female
PUR
Figure 24
5
Right-angle female
PUR
Figure 24
8
Axial female
PUR
Figure 25
8
Axial female
PUR
Figure 25
8
Right-angle female
PUR
Figure 26
8
Right-angle female
PUR
Figure 26
Cables with LED and quick-disconnect plugs • Industry standard M12 right angle femaleplug with open leads • These cables can be used with patch cables. • 2m, 5m and 10m cable lengths
• PUR (polyurethane) jacket for oily and direct sunlight applications • IP67 /IP68 / IP69K, II rated • LED indication for 10-36 VDC PNP sensors only
M12 Quick-Disconnect Cables with LED Indicator (Euro, Micro DC-Single Key) Part Number Price Length Poles Connector
white wire Pin 2
black wire Pin 4
LED Jacket Dimensions
M12 Quick-Disconnects EVC178* $11.00 2m (6.5 ft)
4
Right-angle female Yes
PUR
Figure 12
EVC179* $11.50 5m (16.4 ft)
4
Right-angle female Yes
PUR
Figure 12
EVC180* $14.00 10m (32.8 ft)
4
Right-angle female Yes
PUR
Figure 12
LED Models’ Wiring
*Note: LED for 10 to 36 VDC PNP devices only. Do not use with NPN or analog ouput devices. Do not use when white wire (Pin 2) is used for selection of a sensor function. Do not use when emitter has check function.
Book 3 (14.3)
eWD-70
Sensor Cables and Connectors
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of June 29, 2016. Check Web site for most current prices.
Sensor Cables and Connectors Cable Specifications Specification Length Nominal Voltage
M8 2m (6.5 ft) / 7m (23 ft)
5m (16.4 ft)
50 VAC/75 VDC
60 VAC/VDC
Max Current
2m (6.5 ft) / 7m (23 ft)
4A
3/4 pin: 250 VAC/VDC, 4A 5 pin: 125 VAC/VDC, 4A 8 pin: 30 VAC/VDC, 2A 12 pin: 30 VAC/VDC, 1.5A
N/A IP67
IP65 / IP68 / IP69K
Temperature Range
Drag Chain (Roller Cable Tray) Suitability
Environmental Function Display Power LED Switching Status LED
Nickel plated Zinc
Gold plated Copper-Tin Alloy (CuSn)
Gold plated brass
0.5 Nm
0.4 Nm
0.5 Nm
0.4 Nm
0.6 Nm
0.25 mm2
0.25 mm2
0.25 mm2
0.34 mm2
4 x 0.34 mm2 (4 x 22 AWG) 5 x 0.34 mm2 (5 x 22 AWG) 8 x 0.25 mm2 (8 x 24 AWG) 12 x 0.14 mm2 (12 x 26 AWG)
5mm
PVC: 4mm PUR: 4mm
5mm
PVC: 4.2 mm PUR: 4.3 mm
PVC: 5 - 5.2 mm PUR: 6.0 mm
-25° to +80°C (-13° to 176°F)
-25° to 90°C (-13° to 194°F)
N/A
Halogen/Silicone free
(24 AWG)
(24 AWG)
(24 AWG)
(22 AWG)
PVC: -30° to 70°C -25° to +80°C (-22° to 158°F) (-13° to 176°F) PUR: -50° to 90°C (-58° to 194°F) N/A
Halogen/Silicone free
PVC: -25° to +70°C (-13° to 158°F) PUR: -25° to +85°C (-13° to 185°F) N/A
N/A N/A
Bending Radius
min. 10 x cable diameter
Bending Cycles
N/A
Travel Speed
N/A
Torsional Strain
N/A
Agency Approvals
IP67
Polyurethane (PUR) or Polyvinyl-chloride (PVC)
Contacts Material
Ø Outer Cable
PVC: IP68 PUR: IP68 / IP69K
IP67
Nickel plated brass
Housing Material
Conductors Cross Section (AWG)
3m (9.8 ft) / 5m (16.4 ft) / 10m (32.8 ft) / 15m (49.2 ft) 30 VAC/VDC; 125 VAC/VDC; 250 VAC/VDC
4A
Material Nut
Tightening Torque
5m (16.4 ft)
250 VAC/VDC
LED Current Loading Protection Degree
M12 7000 Series (unshielded)
CD Series
RoHS
RoHS (UL E325311 8/12 pole)
Book 3 (14.3)
w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s
Sensor Cables and Connectors
eWD-71
Prices as of June 29, 2016. Check Web site for most current prices.
Sensor Cables and Connectors Cable Specifications
M12 7000 Series (shielded)
M12 with LED
Length
5m (16.4 ft) / 10m (32.8 ft)
2m (6.5 ft) / 5m (16.4 ft) / 10m (32.8 ft)
Nominal Voltage
30 VAC/VDC / 60 VAC/VDC
10 to 36 VDC
Specification
Max Current
2A / 4A
4A
LED Current Loading
N/A
10 V input Brown wire LED: 1.7 mA White and/or Black LED: 0.9 mA 36V input Brown wire LED: 7.3 mA White and/or Black LED: 4.7 mA
Protection Degree
IP67
IP67 / IP68 / IP69K
Nickel plated Zinc
Nickel plated Brass
Material Nut Jacket Material
Polyurethane (PUR)
Housing Material Contacts Material Tightening Torque
Polyurethane (PUR) Gold plated Brass 0.6 Nm
0.6 to 1.5 Nm
4 x 0.34 mm2 (4 x 22 AWG) 5 x 0.34 mm2 (5 x 22 AWG) 8 x 0.25 mm2 (8 x 24 AWG)
4 x 0.34 mm2
Ø Outer Cable
4/5 pole: 5.9 mm 8 pole: 7mm
5mm
Temperature Range
-25° to +80°C (-13° to 176°F)
-25° to +90°C (-13° to 194°F)
Function Display Power LED
N/A
Green
Switching Status LED Bending Radius Bending Cycles
N/A
Drag Chain (Roller Cable Tray) Suitability
Conductors Cross Section (AWG)
Travel Speed
Torsional Strain Agency Approvals
(4 x 22 AWG)
2 x Yellow min. 10 x cable diameter
N/A N/A
>5 million Max. 3.3 m/s for a horizontal travel length of 5 meters and max. acceleration of 5 m/s2
N/A
±180°/m
RoHS
UL File E191684, RoHS
UL Reference Part Number Mini-Series Female Cord Connectors Series M12, UL Catalog Number ADOAH043MSS0002H04 EVC178 ADOAH043MSS0005H04 EVC179 ADOAH043MSS0010H04 EVC180 Note: Shown in UL file under Mini-series Female Cord Connectors using catalog number
Book 3 (14.3)
eWD-72
Sensor Cables and Connectors
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of June 29, 2016. Check Web site for most current prices.
Sensor Cables and Connectors Dimensions mm [inches]
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 7
Figure 6
Figure 8
Book 3 (14.3)
w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s
Sensor Cables and Connectors
eWD-73
Prices as of June 29, 2016. Check Web site for most current prices.
Sensor Cables and Connectors Dimensions mm [inches]
Figure 9
Figure 10
Figure 11
Figure 12
Figure 13
Figure 14
Figure 15
Figure 16
Book 3 (14.3)
eWD-74
Sensor Cables and Connectors
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of June 29, 2016. Check Web site for most current prices.
Sensor Cables and Connectors Dimensions mm [inches]
Figure 17
Figure 18
Figure 19
Figure 20
Figure 21
Figure 22
Figure 23
Figure 24
Figure 25
Figure 26
Book 3 (14.3)
w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s
Sensor Cables and Connectors
eWD-75
Prices as of June 29, 2016. Check Web site for most current prices.
Sensor Cables and Connectors Patch cables with quick-disconnect plugs on each end Available patch cables include: • Industry standard M8 and M12 screw-lock connectors • One male and one female connector • Axial and right-angle connector models
• 1m and 3m cable lengths • PVC (polyvinyl chloride)jacket for typical industrial applications • IP67 rated
M8 Patch Cables with Quick-Disconnect on Each End (Pico, Nano) Part Number Price Length M8 Quick-Disconnect Patch Cables
Poles
Connectors
Jacket
Dimensions
2 Axial - One male and one female connector 2 Right-angle - One male and one female connector 2 Axial - One male and one female connector 2 Right-angle - One male and one female connector
PVC
Figure 1
PVC
Figure 3
PVC
Figure 2
PVC
Figure 3
CDP08-0A-010-AA
$8.25
1m (3.28 ft)
3
CDP08-0A-010-BB
$8.25
1m (3.28 ft)
3
CDP08-0A-030-AA
$10.00 3m (9.84 ft)
3
CDP08-0A-030-BB
$8.25
3
3m (9.84 ft)
M12 Patch Cables with Quick-Disconnect on Each End (Euro, Micro DC-Single Key) Part Number Price Length M12 Quick-Disconnect Patch Cables
Poles
CDP12-0B-010-AA
$8.25 1m (3.28 ft.)
4
CDP12-0B-010-BB
$8.25 1m (3.28 ft.)
4
CDP12-0B-030-AA
$8.25 3m (9.84 ft.)
4
CDP12-0B-030-BB
$10.00 3m (9.84 ft.)
4
7000-40041-2150100 $12.00 1m (3.28 ft.)
5
7000-40041-2150300 $15.00 3m (9.84 ft.)
5
Connectors 2 Axial - One male and one female connector 2 Right-angle - One male and one female connector 2 Axial - One male and one female connector 2 Right-angle - One male and one female connector 2 Axial - One male and one female connector 2 Axial - One male and one female connector
Jacket
Dimensions
PVC
Figure 4
PVC
Figure 5
PVC
Figure 4
PVC
Figure 5
PVC
Figure 7
PVC
Figure 7
Patch Cables with LED
Available patch cables with LED include: • Right-angle M12 female plug with LED indication on one end and axial male plug on the other end • 0.3m, 0.6m, 1m, 2m, 5m, and 10m cable lengths
white wire Pin 2
• PUR (polyurethane) jacket for oily and direct sunlight applications • IP67 /IP68 / IP69K, II rated • LED indication for 10 -36 VDC PNP sensors only
M12 Patch Cables with LED Indicator (Euro, Micro DC-Single Key) Part Number Price Length M12 Patch Cables
black wire Pin 4
LED Models’ Wiring
Poles Connectors
LED Jacket Dimensions
EVC322* $11.00 0.3m (0.98 ft)
4
Right-angle female, axial male
Yes
PUR
Figure 6
EVC323* $12.00 0.6m (1.97 ft)
4
Right-angle female, axial male
Yes
PUR
Figure 6
EVC324* $12.50 1m (3.28 ft)
4
Right-angle female, axial male
Yes
PUR
Figure 6
EVC325* $14.50 2m (6.5 ft)
4
Right-angle female, axial male
Yes
PUR
Figure 6
EVC326* $17.00 5m (16.4 ft)
4
Right-angle female, axial male
Yes
PUR
Figure 6
EVC327* $21.50 10m (32.8 ft)
4
Right-angle female, axial male
Yes
PUR
Figure 6
*Note: LED for 10 to 36 VDC PNP devices only. Do not use with NPN or analog ouput devices. Do not use when white wire (Pin 2) is used for selection of a sensor function. Do not use when emitter has check function. Book 3 (14.3)
eWD-76
Sensor Cables and Connectors
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of June 29, 2016. Check Web site for most current prices.
Sensor Cables and Connectors Cable Specifications Specification Length
M8
M12
1m (3.28 ft.) / 3m (9.84 ft.)
Nominal Voltage
4A
LED Current Consumption
N/A
Material Nut Jacket Material Housing Material Contacts Material Conductors Cross Section (AWG) Tightening Torque
Drag Chain (Roller Cable Tray) Suitability
Ø Outer Cable Temperature Range Function Display LED Switching Status LED
0.3m (0.98 ft) / 0.6m (1.97 ft) / 1m (3.28 ft) 2m (6.5 ft) / 5m (16.4 ft) / 10m (32.8 ft)
125 VAC/VDC 250 VAC/VDC
60 VAC/VDC
Max Current
Protection Degree
M12 with LED
10 to 36 VDC 4A 10V input Brown wire LED: 1.7 mA White and/or Black LED: 0.9 mA 36V input Brown wire LED: 7.3 mA White and/or Black LED: 4.7 mA
IEC IP67 Zinc pressure die casting surface Nickel plated brass (Ni4-6), Nickel plated brass PolyVinyl Chloride (PVC)
IEC IP67/IP68/IP69K
Polyurethane (PUR)
Connector: Orange PUR, Socket: Black PUR
Nickel plated brass Polyurethane (PUR)
Copper-tin(CuSn) plated brass
Gold plated brass
0.34 mm²
0.34 mm² (22 AWG) Plug: 0.6 to 1.5 Nm (take into account the maximum value of the counterpart) Socket: 0.6 to 1.5 Nm 5mm
0.5 Nm
0.6 Nm, 0.5 Nm
5mm
5.2 mm, 5mm
-25° to +70°C (-13° to 158°F)
-25° to +90°C (-13° to 194°F)
N/A
Green
N/A
2 x Yellow
Bending Radius
min. 10 x cable diameter
Bending Cycles
>5 million
Travel Speed Torsional Strain
Agency Approvals
N/A
Max. 3.3 m/s for a horizontal travel length of 5 m and max. acceleration of 5 m/s²
N/A
±180°/m
RoHS
UL File E191684, RoHS
UL Reference Part Number EVC322 EVC323 EVC324 EVC325 EVC326 EVC327
Cable Assemblies Series M12, UL Catalog Number VDOAH043MSS00.3H04STGH040MSS VDOAH043MSS00.6H04STGH040MSS VDOAH043MSS0001H04STGH040MSS VDOAH043MSS0002H04STGH040MSS VDOAH043MSS0005H04STGH040MSS VDOAH043MSS0010H04STGH040MSS
Note: Shown in UL file under Cable Assemblies using catalog number
Book 3 (14.3)
w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s
Sensor Cables and Connectors
eWD-77
Prices as of June 29, 2016. Check Web site for most current prices.
Sensor Cables and Connectors Dimensions Figure 1
mm [inches]
Figure 2
Figure 4
Figure 3
Figure 6
Figure 5
Figure 7
Book 3 (14.3)
eWD-78
Sensor Cables and Connectors
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of June 29, 2016. Check Web site for most current prices.
IP69K-rated M12 Sensor Cables Cable Specifications Specification Length
M12
1/2”
0.3m (0.98 ft), 0.6m (1.97 ft), 1m (3.3 ft), 2m (6.6 ft), 5m (16.4 ft), 10m (32.8 ft)
5m (16.4 ft), 10m (32.8 ft)
250 VAC/300 VDC
300 VAC/VDC
4A
4A
IEC IP67 / IP68 / IP69K
IEC IP67 / IP68 / IP69K
Nominal Voltage Max Current Protection Degree Material Nut Jacket Material Housing Material Contacts Material Tightening Torque Conductors Cross Section (AWG) Ø Outer Cable Temperature Range Environmental Bending Radius Agency Approvals
316L Stainless steel
316L Stainless steel
PolyVinyl Chloride (PVC)
PolyVinyl Chloride (PVC)
PolyVinyl Chloride (PVC)
PolyVinyl Chloride (PVC)
Gold plated
Gold plated 0.6 to 1.5 Nm
22 AWG
22 AWG
4.9 mm
4.5 mm
-25° to 100°C (-13° to 212°F)
-10° to 100°C (14° to 212°F)
Halogen free, Silicone free
Halogen free, Silicone free
min. 10 x cable diameter UL E191684
Wiring - M12 DC
UL E177636
UL Reference
EVT221, EVT222, EVT223, EVT224 Brown White Blue Black
EVT225, EVT226, EVT227, EVT228, EVT229, EVT230, EVT231, EVT232, EVT233, EVT234
Wiring - 1/2” Micro AC
Part Number UL Catalog Number EVT221 ADOGH040VAS0005E04 EVT222 ADOAH040VAS0005E04 EVT223 ADOGH040VAS0010E04 EVT224 ADOAH040VAS0010E04 EVT225 VDOGH040VAS00.3E04STGH040VAS EVT226 VDOAH040VAS00.3E04STGH040VAS EVT227 VDOGH040VAS00.6E04STGH040VAS EVT228 VDOAH040VAS00.6E04STGH040VAS EVT229 VDOGH040VAS0001E04STGH040VAS EVT230 VDOAH040VAS0001E04STGH040VAS EVT231 VDOGH040VAS0002E04STGH040VAS EVT232 VDOAH040VAS0002E04STGH040VAS EVT233 VDOGH040VAS0005E04STGH040VAS EVT234 VDOAH040VAS0005E04STGH040VAS
E18446, E18447, E18448, E18449 Green Red/Black Red/White
Book 3 (14.3)
eWD-84
Sensor Cables and Connectors
1 - 8 0 0 - 633 - 0 4 0 5
For the latest prices, please check AutomationDirect.com.
BX Series High Resolution Area Sensor High resolution area sensor (light screen) - DC • 70 mm controlled area height • Operating distance up to 2m • Adjustable sensitivity • NPN or PNP with NO/NC selectable output • Emitter and receiver LED status indicators • IP67 rated
BX80 Series Area Sensor Selection Chart Part Number Price Function Sensing Range Output State BX80B-1N-0H $197.00 Receiver BX80B-1P-0H $197.00 Receiver N.O./N.C. 2m (78.74in) Emitter
Connection
Wiring
NPN PNP Receiver dependent
Figure 1 Figure 2
M12 (12mm) connector
Receiver dependent
Specifications Type Sensing Distance Light Spot Diameter Emission Sensitivity Output Type Operating Voltage No-load Supply Current Operating (Load) Current Off-state (Leakage) Current Voltage Drop Switching Frequency Ripple Time Delay Before Availability (tv) Short-Circuit Protection Operating Temperature Protection Degree (DIN 40050) Emitter’s LED Indicators - Switching Status
Dimensions
Thru-beam
(mm)
2m (2.56 ft) N/A Infrared (880nm)
27
14.7
NPN or PNP; N.O./N.C.selectable
44
20
Fixed
9
1.4
o4.2
7.2
12-24VDC
66
m100mA
110
120
Emitter: 100mA; Receiver: 50mA m10µA 11.5
1.2volt maximum at 100mA
23.5 10 15 5
Ch 24
23 3 16.5
500ms Yes (switch autoresets after overload is removed)
6.5
50Hz m10%
11.5
Ch 13
14
BX80S-10-0H $166.00
selectable
Logic
-25° to 50°C (-13° to 122°F)
Receiver’s LED Indicators - Switching Status Housing Material Lens Material Shock/Vibration Tightening Torque Weight Agency Approvals
IEC IP67 Green (power), Red (sync. alarm), Yellow (area occupied) Green (power), Red (alignment alarm), Yellow (output energized) Polybutylene Terephthalate (PBT)
Receiver
Emitter
25 Nm (18.44 lb-ft) max.
_
BU/3
300g (10.58oz)
+
BN/1
cULus E187310, CE
Light on N.C. Dark on N.O.
12-24VDC
+
SYNC + WH/2
N.O.
Connectors
BN/1 Receiver Supply (-)
Output
tPHS-134
Photoelectric Sensors
Sync (+)
Supply (+)
+
BN/1 BK/4
Load
WH/2
Receiver
BU/3
+ _
12-24VDC
+
BN/1
_
BU/3
Load
BK/4
Supply (-)
SYNC Supply (+)
BU/3
SYNC _ BK/4
Emitter
Sync (-)
_
Figure 2
N.C.
Emitter
1
Figure 1
See terminology section
Thru-beam and Diffuse Reflective Reflective Models Models
1 20 16.5
Wiring diagrams
Polycarbonate (PC)
Switching Element Function
12 1
32 o 1.5
Sync
_
BK/4
SYNC + WH/2
_
WH/2
1-800-633-0405
For the latest prices, please check AutomationDirect.com.
Reflectors RL series reflectors for polarized reflective photoelectric sensors (all models)
• Suitable for use with polarized light photoelectric sensors • Shapes and sizes for most applications • Miniature types for close mounting in multiple sensor installations • Single hole, dual hole and self-adhesive mounting types available • Single and 10-packs available
Installation notes
• Keep the reflector surface clean to ensure peak detection performance. This is especially true when the maximum sensing range is being used. Clean using a damp cloth. • When selecting a reflector, it is important to consider the ambient conditions it will be exposed to. Dusty or high humidity conditions may reduce the sensing range as much as 90%. • Reflectors should be positioned at a 90° angle to the optical axis with a tolerance of ±15°.
Specifications Model
Price
RL102
Quantity
Dimensions
$35.00
10 per pack
RL102-1
$3.75
1 per pack
RL103
$40.00
10 per pack
RL103-1
$4.25
1 per pack
RL104
$40.00
10 per pack
RL104-1
$4.25
1 per pack
RL105
$35.00
10 per pack
RL105-1
$3.75
1 per pack
RL106G
$40.00
10 per pack
RL106G-1
$4.25
1 per pack
RL110
$18.00
10 per pack
RL110-1
$2.00
1 per pack
RL116
$18.00
10 per pack
RL116-1
$2.00
1 per pack
RL100DA4
$32.50
1 per pack
RL100DC4
$10.00
1 per pack
RL100DQ1
$7.50
1 per pack
RL111G
$52.00
10 per pack
RL111G-1
$6.00
1 per pack
RL112G
$40.00
10 per pack
RL112G-1
$4.25
1 per pack
19 x 73mm [0.75 x 2.87 in]
RL113G
$46.00
10 per pack
51.4 x 60.3mm [2.02 x 2.37 in]
RL113G-1
$5.00
1 per pack
Degree of Protection
Mounting
Materials
Ø25mm [0.98 in] Customer-supplied adhesive or other mounting method required
Ø34.5mm [1.36 in] Ø46mm [Ø1.81 in] 90 x 40mm [3.54 x 1.58 in]
two Ø4.3 mm holes
182 x 42mm [7.17 x 1.65 in]
two Ø6 mm holes
Ø84mm [3.31 in]
Reflective face: PMMA Polymethylmethacrylate (acrylic); base material: ABS (Acrylonitrile-butadiene-styren)
one Ø5 mm hole IEC IP67
41 x 60mm [3.54 x 2.36 in]
two M3 holes
200 x 300mm [7.87 x 11.81 in] 50 x 300mm [1.97 x 11.81 in] 100 x 100mm [3.94 x 3.94 in]
Self-adhesive
Paper (Acrylic tape with micro prism)
22.5 x 47mm [0.89 x 21.85 in] two M3 slots
Reflective face: PMMA Polymethylmethacrylate (acrylic); base material: ABS (Acrylonitrile-butadiene-styren)
two M4 slots
Not recommended for applications involving moist air environments or water immersion.
www.automationdirect.com/photoelectric
Photoelectric Sensors
tPHS-135
For the latest prices, please check AutomationDirect.com.
Reflectors RL series reflectors for polarized reflective laser photoelectric sensors (FALN series)
• Suitable for use with polarized light laser photoelectric sensors • Sizes for most applications • Miniature types for close mounting in multiple sensor installations • Single and 5-packs available
Dimensions
Specifications Model
RL201
RL201-1
RL203
RL203-1
RL204
RL204-1
Price
$32.00
$7.00
$30.00
$6.50
$26.00
$5.75
Quantity (per package)
5
1
5
1
5
1
Dimensions
60mm x 82mm 2.36 in x 3.23 in
Degree of Protection Mounting
1
two Ø 0.4 mm holes
Materials
19mm x 60mm 0.75 in x 2.36 in IEC IP67
20mm x 32mm 0.80 in x 1.26 in
two Ø 0.4 mm holes
two Ø 0.3 mm holes
Acrylic/polycarbonate
1 Not recommended for applications involving moist air environments or water immersion.
mm [inches]
RL102/RL102-1
RL103/RL103-1
RL104/RL104-1
RL105/RL105-1
RL106G/RL106G-1
tPHS-136
Photoelectric Sensors
1-800-633-0405
For the latest prices, please check AutomationDirect.com.
Reflectors Dimensions mm [inches]
RL110/RL110-1
RL111G/RL111G-1
RL112G/RL112G-1
RL113G/RL113G-1
RL116/RL116-1
RL201/RL201-1
RL203/RL203-1
RL204/RL204-1
www.automationdirect.com/photoelectric
Photoelectric Sensors
tPHS-137
For the latest prices, please check AutomationDirect.com.
Shutters and Adapters ST0S1 through ST0S8 shutters for M18 (18 mm) through-beam sensors (SSE / SSR) • Reduces the emitted beam, allowing the detection of small targets • Shutter consists of an aluminum cap and aperture with an o-ring and glass lens, which can screw onto the optical head of either the emitter or receiver
Sensing Distance (when used with SSE / SSR Model photoelectric switches) Model
ST0S1
ST0S2
ST0S4
ST0S6
ST0S8
Price
$13.50
$13.50
$13.50
$13.50
$13.50
1
2
4
6
8
N/A N/A
N/A N/A
1.5 2
3.5 3
6.5 4
Ø x shutter (mm) Distance (m) object (mm)
Table shows sensing distance and minimal detectable object.
ST03 right-angle M18 (18 mm) beam adapter Beam Adapters Part Number Price ST03
tPHS-138
Description
For use with M18 retroreflective and through-beam photoelectric switches (not for use with diffuse reflection $13.50 sensors). Allows 90° light detection using an internal mirror set at 45° to the optical axis. Sensitivity loss is about 20-30%.
Photoelectric Sensors
1-800-633-0405
For the latest prices, please check AutomationDirect.com.
Accessories: Mounting Brackets ST12A axial bracket For mounting M12 (12mm) sensors. Has two mounting holes (use 3mm screws) and allows the rotation of an optical axis for right-beam angle adapter sensors.
Brackets
ST12C right-angle bracket Angular mounting bracket for use with M12 (12mm) sensors. Has two mounting holes (use 3mm screws) and allows the rotation of an optical axis for axial sensors.
Brackets
Part Number Price Description $2.00 Metal axial bracket for 12mm sensors, 1/pk ST12A $6.00 316L stainless steel axial bracket for 12mm sensors, 1/pk ST12A7W
Part Number Price Description $6.00 Metal right angle bracket for 12mm sensors, 1/pk ST12C $6.00 316L stainless steel right angle bracket for 12mm sensors, 1/pk ST12C7W
ST18A axial bracket
ST18C right-angle bracket
Mounting bracket for M18 (18mm) sensors. Has two mounting holes (use 4mm screws) and allows the rotation of an optical axis for right-beam angle adapter sensors.
Angular mounting bracket for M18 (18mm) sensors. Has two mounting holes (use 4mm screws) and allows the rotation of an optical axis for axial sensors.
Brackets Part Number Price Description $1.25 Metal axial bracket for 18mm sensors, 1/pk ST18A $6.00 316L stainless steel axial bracket for 18mm sensors, 1/pk ST18A7W
Brackets Part Number Price Description $1.25 Metal right angle bracket for 18mm sensors, 1/pk ST18C $6.00 316L stainless steel right angle bracket for 18mm sensors, 1/pk ST18C7W
www.automationdirect.com/photoelectric
Photoelectric Sensors
tPHS-139
For the latest prices, please check AutomationDirect.com.
Accessories: Mounting Brackets ST02 plastic swivel bracket M18 (18 mm) Brackets Part Number
Price
Description
ST02
$8.25
Plastic mounting bracket for use with M18 photoelectric switches. Has a ball-joint and set screws to adjust sensor orientation. Allows orientation in all directions for retroreflective and through-beam sensors. (Will not work with C18 series).
Dimensions inches [mm]
tPHS-140
Photoelectric Sensors
1-800-633-0405
For the latest prices, please check AutomationDirect.com.
Accessories: Mounting Brackets ST-S8 and ST-5072 mounting brackets
Contrast Sensor Brackets Part Description Number Price ST-S8-FRM $8.00 Datalogic mounting bracket, 304 stainless steel, vertical. For use with S8 series contrast sensors. ST-5072
mounting bracket, 304 stainless steel, right-angle. For use with S8 series contrast $10.00 Datalogic sensors.
Weight [lb] 0.48 0.10
Dimensions mm [inches] ST-S8-FRM
ST-5072
See our website: www.AutomationDirect.com for complete Engineering drawings.
tPHS-142
Photoelectric Sensors
1-800-633-0405