Preview only show first 10 pages with watermark. For full document please download

Specifications

   EMBED


Share

Transcript

For the latest prices, please check AutomationDirect.com. C18 Series Photoelectric Sensors M18 (18 mm) metal – DC • 36 models available • Diffuse, Polarized reflective, Through-beam, and Diffuse with background suppression models • Long operating distances • Scratch resistant and easy-to-clean glass lens • Adustable sensitivity (diffuse models only) • Axial cable or 12 mm quick-disconnect models • Complete overload protection • IP67 rated C18 Series Photoelectric Sensor Selection Chart Part Number Price Sensing Range Output State Optics Logic Connection Wiring Dimensions Diffuse 1 N.O. and 1 N.C. Axial NPN 2 m (6.5’) axial cable C18D-0N-1A $41.00 1 N.O. and 1 N.C.. Axial PNP 2 m (6.5’) axial cable C18D-0P-1A $41.00 1 N.O. and 1 N.C. Axial NPN M12 (12 mm) connector C18D-0N-1E $41.00 1 N.O. and 1 N.C. Axial PNP M12 (12 mm) connector C18D-0P-1E $41.00 Up to 600 mm (23.62 in) 1 N.O. and 1 N.C.. Right-angle NPN 2 m (6.5’) axial cable C18D-0N-2A $36.25 1 N.O. and 1 N.C. Right-angle PNP 2 m (6.5’) axial cable C18D-0P-2A $54.00 1 N.O. and 1 N.C. Right-angle NPN M12 (12 mm) connector C18D-0N-2E $54.00 1 N.O. and 1 N.C.. Right-angle PNP M12 (12 mm) connector C18D-0P-2E $54.00 Diffuse with background suppression Axial NPN 2 m (6.5’) axial cable C18B-AN-1A $67.00 Axial PNP 2 m (6.5’) axial cable C18B-AP-1A $67.00 10-120 mm N..O. (0.39 to 4.72 in) Axial NPN M12 (12 mm) connector C18B-AN-1E $67.00 Axial PNP M12 (12 mm) connector C18B-AP-1E $67.00 Right-angle NPN 2 m (6.5’) axial cable C18B-AN-2A $71.75 Right-angle PNP 2 m (6.5’) axial cable C18B-AP-2A $104.00 10-120 mm N.O. (0.39 to 4.72 in) Right-angle NPN M12 (12 mm) connector C18B-AN-2E $71.75 Right-angle PNP M12 (12 mm) connector C18B-AP-2E $104.00 Polarized reflective *Purchase reflectors separately. Axial NPN 2 m (6.5’) axial cable C18P-AN-1A $43.50 Axial PNP 2 m (6.5’) axial cable C18P-AP-1A $43.50 Up to 2 m N.O. (6.6 ft) Axial NPN M12 (12 mm) connector C18P-AN-1E $43.50 Axial PNP M12 (12 mm) connector C18P-AP-1E $43.50 Right-angle NPN 2 m (6.5’) axial cable C18P-AN-2A $57.00 Right-angle PNP 2 m (6.5’) axial cable C18P-AP-2A $57.00 Up to 2 m N.O. (6.6 ft) Right-angle NPN M12 (12 mm) connector C18P-AN-2E $57.00 Right-angle PNP M12 (12 mm) connector C18P-AP-2E $57.00 Through-beam **Purchase one receiver and one emitter for a complete set. Axial NPN 2 m (6.5’) axial cable C18R-0N-1A $38.00 Axial PNP 2 m (6.5’) axial cable C18R-0P-1A $38.00 Up to 6 m 1 N.O. and 1 N.C. (19.7 ft) Axial NPN M12 (12 mm) connector C18R-0N-1E $38.00 Axial PNP M12 (12 mm) connector C18R-0P-1E $38.00 $28.00 Axial 2 m (6.5’) axial cable C18E-00-1A Receiver Receiver dependent Receiver dependent dependent M12 (12 mm) connector $28.00 Axial C18E-00-1E Right-angle NPN 2 m (6.5’) axial cable C18R-0N-2A $50.00 Right-angle PNP 2 m (6.5’) axial cable C18R-0P-2A $50.00 Up to 6 m 1 N.O. and 1 N.C. (19.7 ft.) Right-angle NPN M12 (12 mm) connector C18R-0N-2E $50.00 Right-angle PNP M12 (12 mm) connector C18R-0P-2E $41.00 $38.00 Right-angle 2 m (6.5’) axial cable C18E-00-2A Receiver Receiver dependent Receiver dependent $38.00 Right-angle dependent M12 (12 mm) connector C18E-00-2E www.automationdirect.com/photoelectric Characteristic Curves Diagram 3 Figure 1 Chart 5 Diagram 4 Figure 1 Chart 5 Diagram 3 Figure 2 Chart 5 Diagram 4 Figure 2 Chart 5 Diagram 3 Figure 3 Chart 6 Diagram 4 Figure 3 Chart 6 Diagram 3 Figure 4 Chart 6 Diagram 4 Figure 4 Chart 6 Diagram 1 Figure 1 Chart 1 Diagram 2 Figure 1 Chart 1 Diagram 1 Figure 2 Chart 1 Diagram 2 Figure 2 Chart 1 Diagram 1 Figure 3 Chart 2 Diagram 2 Figure 3 Chart 2 Diagram 1 Figure 4 Chart 2 Diagram 2 Figure 4 Chart 2 Diagram 1 Figure 1 Chart 3 Diagram 2 Figure 1 Chart 3 Diagram 1 Figure 2 Chart 3 Diagram 2 Figure 2 Chart 3 Diagram 1 Figure 3 Chart 4 Diagram 2 Figure 3 Chart 4 Diagram 1 Figure 4 Chart 4 Diagram 2 Figure 4 Chart 4 Diagram 3 Figure 1 Chart 7 Diagram 4 Figure 1 Chart 7 Diagram 3 Figure 2 Chart 7 Diagram 4 Figure 2 Chart 7 Diagram 5 Figure 5 Chart 7 Diagram 5 Figure 6 Chart 7 Diagram 3 Figure 3 Chart 8 Diagram 4 Figure 3 Chart 8 Diagram 3 Figure 4 Chart 8 Diagram 4 Figure 4 Chart 8 Diagram 5 Figure 7 Chart 8 Diagram 5 Figure 8 Chart 8 Photoelectric Sensors tPHS-45 For the latest prices, please check AutomationDirect.com. C18 Series Photoelectric Sensors Specifications Diffuse Models Type Sensing Distance Emission Light Spot Diameter Sensitivity Diffuse Through-beam1 Diffuse with background suppression 10 to 120 mm (0.39 to 4.72 in)3 Polarized reflection 600 mm (23.62in)2 2 m (6.6 ft) 6 m (19.7 ft) LED red (660nm) LED red (660nm) LED red polarized (660 nm) LED red (660nm) See charts – Adjustable one-turn pot. Output Type Through-beam Models Diffuse Models with Background Suppression Reflective Models NPN or PNP; 1 L.O. and 1 D.O. NPN or PNP; L.O. only 20 mA 25 mA Operating Voltage NPN or PNP; D.O. only NPN or PNP; 1 L.O. and 1 D.O. 10-36 VDC No Load Supply Current Operating (Load) Current Off-state (Leakage) Current Voltage Drop Switching Frequency Ripple Time Delay Before Availability (tv) Short-Circuit Protection Operating Temperature Range Protection Degree (DIN 40050) LED Indicators - Switching Status Housing Material Lens Material Shock/Vibration Tightening Torque Weight Connectors Agency Approvals 15 mA Receiver: 10 mA Emitter:15 mA 1kHz 1kHz 20ms 20ms m200 mA m10µ A m2.0 V 1kHz 500Hz m20% 60ms 20ms Yes (switch autoresets after overload is removed) -25° to + 55°C (-13° to 131°F) IEC IP67 Yellow (output state, output energized), green (excess light indication). Emitter has no LED Chrome-plated brass Glass See terminology section 50 Nm (36.88 lb-ft) 65.22 g (2.3 oz). 2m (6.5’) axial cable; M12 (12mm) connector UL file E328811 Notes: 1Through-beam sensors must be used in pairs consisting of one receiver and one emitter. 2With 200x200mm white matte paper. 3With 100x100mm white matte paper. Wiring diagrams Warning: These products are not safety sensors and are not suitable for use in personal safety applications. Diagram 1 NPN Output Diagram 2 Connector PNP Output M12 Connector Diagram 3 4-Wire NPN Output Diagram 4 4-Wire PNP Output Diagram 5 Emitter Switching Element Function Emitter test input (<4V: OFF / >8V or open: ON) 0.5mA tPHS-46 Photoelectric Sensors Thru-beam and Reflective Models Diffuse Models Light on N.C. Dark on N.O. N.O. N.C. 1-800-633-0405 For the latest prices, please check AutomationDirect.com. C18 Series Photoelectric Sensors Dimensions (mm) Figure 2 1.14 (29) 0.16 (4) Potentiometer (Diffuse models only) Dia. 0.18 (4.5) Figure 3 2.5 (63.5) 0.32 (8) 0.51 (13) Potentiometer (diffuse models only) 0.34 (8.5) 0.31 (7.8) 0.31 (7.8) 1.97 (50) 1.14 (29) 0.16 (4) Figure 1 Figure 4 0.15 (3.9) 0.34 (8.5) Potentiometer (Diffuse models only) Potentiometer (Diffuse models only) Dia. 0.18 (4.5) 2.95 (75) 0.31 (7.8) 0.32 (8) 2.42 (61.5) 0.16 (4) 1.56 (39.5) 1.56 (39.5) 2.42 (61.5) 0.15 (3.9) Dia. 0.65 (16.6) Figure 5 Figure 6 2.5 (63.5) 1.97 (50) 0.7(16.4) 0.2 (5) 0.32 (8) 0.16 (4) Figure 8 C18E-00-1A LLK-1180-000 2.95 (75) SW24 SW24 2.42 (61.5) C18E-00-2A LLK-1180W-000 www.automationdirect.com/photoelectric 0.5 (13) C18E-00-1E LLS-1180-000 0.32 (8) Ø 0.67 (16.9) M12x1 (4.5) 0.16 (4) Ø 0.18 0.34 (8.5) M18x1 0.15 (3.9) Figure 7 0.34 (8.5) 0.16 (4) 0.34 (8.5) 2.42 (61.5) 0.32 0.53 (8) (13.5) Note: Dimensions are in inches (millimeters). C18E-00-2E LLS-1180W-000 Photoelectric Sensors tPHS-47 For the latest prices, please check AutomationDirect.com. C18 Series Photoelectric Sensors Characteristic Curves Chart 1 (Diffuse with background suppression C18B-*--1*) s Chart 2 (Diffuse with Background Suppression C18B-*-2*) [mm] s 140 140 120 120 100 100 80 a 80 60 s 40 a 60 s 40 20 a [mm] [mm] 20 6 4 0 2 2 4 a [mm] 6 Chart 3 (Polarized reflective C18P-*-1*) Chart 5 (Diffuse c18D-*-1* s 6 4 2 0 2 4 6 Chart 4 (Polarized reflective C18P-*-2*) Chart 6 (Diffuse c18D-*-2*) [mm] 700 600 500 a 400 300 s 200 100 a [mm] 80 0 40 40 80 * typical values Chart 7 (Through-beam C18R-*-1*) s Chart 8 (Through-beam C18R-*-2*) s [mm] 28000 [mm] 28000 24000 24000 20000 20000 16000 s 16000 a 12000 12000 8000 a 8000 4000 a [mm] 300 0 300 a [mm] tPHS-48 s 4000 Photoelectric Sensors 300 0 300 1-800-633-0405 Prices as of June 29, 2016. Check Web site for most current prices. Sensor Cables and Connectors Cables with quick-disconnect plugs • PVC (polyvinyl chloride) jacket for typical industrial applications • PUR (polyurethane) jacket for oily and direct sunlight applications • IP67 rated • Industry standard axial and right-angle M8/M12 screw-lock connectors with open leads. The cables listed can be used with patch cables • 2m, 3m, 5m, 7m, 10m and 15m cable lengths CD08-0A-020-C1 and -A1 shown M8 Quick-Disconnect Cables (Pico, Nano) Part Number Price M8 Quick-Disconnects $8.25 CD08-0A-020-A1 $8.25 CD08-0A-020-C1 $10.50 CD08-0A-050-A1 $11.25 CD08-0C-050-A1 $10.50 CD08-0A-050-C1 $11.25 CD08-0C-050-C1 $13.00 CD08-0A-070-A1 $13.00 CD08-0A-070-C1 Length Poles Connector Jacket Dimensions 2m (6.5 ft.) 3 Axial female PVC Figure 1 CD08-0A-050-C1 and -A1 shown 2m (6.5 ft.) 3 Right-angle female PVC Figure 2 5m (16.4 ft.) 3 Axial female PVC Figure 4 5m (16.4 ft.) 3 Axial female PUR Figure 3 5m (16.4 ft.) 3 Right-angle female PVC Figure 5 5m (16.4 ft.) 3 Right-angle female PUR Figure 5 7m (23 ft.) 3 Axial female PVC Figure 1 7m (23 ft.) 3 Right-angle female PVC Figure 2 CD12L-0B-020-A0 and -C0 shown M12 Quick-Disconnect Cables (Euro, Micro DC-Single Key) Part Number Price M12 Quick-Disconnects $10.50 CD12M-0B-050-A1* $12.50 CD12M-0D-050-A1* $10.50 CD12M-0B-050-C1* $12.50 CD12M-0D-050-C1* $8.25 CD12L-0B-020-A0 $8.25 CD12L-0B-020-C0 $13.00 CD12M-0B-070-A1 $13.00 CD12M-0B-070-C1 7000-12221-2141000 $15.00 7000-12221-2141500 $20.00 7000-12341-2141000 $15.00 7000-12341-2141500 $20.00 7000-12241-2150300 $9.50 7000-12241-2150500 $12.00 7000-12241-2151000 $18.00 7000-12361-2150300 $9.50 7000-12361-2150500 $12.00 7000-12361-2151000 $18.00 7000-17041-2950300 $22.00 7000-17041-2950500 $27.00 7000-17041-2951000 $42.00 7000-17061-2950300 $22.00 7000-17061-2950500 $27.00 7000-17061-2951000 $42.00 7000-19041-7050300 $34.00 7000-19041-7050500 $41.00 7000-19041-7051000 $60.00 7000-19061-7050300 $34.00 7000-19061-7050500 $41.00 7000-19061-7051000 $60.00 Length Poles Connector Jacket Dimensions 5m (16.4 ft) 3 Axial female PVC 5m (16.4 ft) 3 Axial female PUR Figure 9 5m (16.4 ft) 3 Right-angle female PVC Figure 10 5m (16.4 ft) 3 Right-angle female PUR Figure 11 2m (6.5 ft) 4 Axial female PVC Figure 6 2m (6.5 ft) 4 Right-angle female PVC Figure 7 7m (23 ft) 4 Axial female PVC Figure 6 7m (23 ft) 4 Right-angle female PVC Figure 7 10m (32.8 ft) 15m (49.2 ft) 10m (32.8 ft) 4 4 4 Axial female Axial female Right-angle female PVC PVC PVC Figure 13 Figure 13 Figure 14 15m (49.2 ft) 4 Right-angle female PVC Figure 14 3m (9.8 ft) 5 Axial female PVC Figure 15 5m (16.4 ft) 5 Axial female PVC Figure 15 10m (32.8 ft) 5 Axial female PVC Figure 15 3m (9.8 ft) 5 Right-angle female PVC Figure 16 5m (16.4 ft) 5 Right-angle female PVC Figure 16 10m (32.8 ft) 3m (9.8 ft) 5m (16.4 ft) 5 8 8 Right-angle female Axial female Axial female PVC PUR PUR Figure 16 Figure 17 Figure 17 10m (32.8 ft) 8 Axial female PUR Figure 17 3m (9.8 ft) 8 Right-angle female PUR Figure 18 5m (16.4 ft) 8 Right-angle female PUR Figure 18 10m (32.8 ft) 8 Right-angle female PUR Figure 18 Figure 8 3m (9.8 ft) 12 Axial female PUR Figure 19 5m (16.4 ft) 12 Axial female PUR Figure 19 10m (32.8 ft) 12 Axial female PUR Figure 19 3m (9.8 ft) 12 Right-angle female PUR Figure 20 5m (16.4 ft) 12 Right-angle female PUR Figure 20 10m (32.8 ft) 12 Right-angle female PUR Figure 20 * Note: Do not use with sensors that require 4-pole cables. CD12M-0B-050-C1 and -A1 shown 7000-12221-2141000 7000-12241-2150500 7000-17041-2951000 7000-19041-7050500 Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s Sensor Cables and Connectors eWD-69 Prices as of June 29, 2016. Check Web site for most current prices. Sensor Cables and Connectors Shielded M12 Cables with quick-disconnect plugs • Industry standard axial and right-angle M12 screw-lock connectors with open leads • Braided shield located inside the cord jacket and connected to the coupling nut • 5m and 10m cable lengths • PUR (polyurethane) jacket for oily and direct sunlight applications • IP67 rated Shielded M12 Quick-Disconnect Cables (Euro, Micro DC-Single Key) Part Number Price Length M12 Quick-Disconnects (shielded) 7000-13201-3310500 $19.00 5m (16.4 ft) 7000-13201-3311000 $29.00 10m (32.8 ft) 7000-13261-3310500 $19.00 5m (16.4 ft) 7000-13261-3311000 $29.00 10m (32.8 ft) 7000-13221-3490500 $22.00 5m (16.4 ft) 7000-13221-3491000 $34.00 10m (32.8 ft) 7000-13281-3490500 $22.00 5m (16.4 ft) 7000-13281-3491000 $34.00 10m (32.8 ft) 7000-17121-2940500 $36.00 5m (16.4 ft) 7000-17121-2941000 $55.00 10m (32.8 ft) 7000-17141-2940500 $36.00 5m (16.4 ft) 7000-17141-2941000 $55.00 10m (32.8 ft) 7000-17121-2941000 7000-17141-2940500 Poles Connector Jacket Dimensions 4 Axial female PUR Figure 21 4 Axial female PUR Figure 21 4 Right-angle female PUR Figure 22 4 Right-angle female PUR Figure 22 5 Axial female PUR Figure 23 5 Axial female PUR Figure 23 5 Right-angle female PUR Figure 24 5 Right-angle female PUR Figure 24 8 Axial female PUR Figure 25 8 Axial female PUR Figure 25 8 Right-angle female PUR Figure 26 8 Right-angle female PUR Figure 26 Cables with LED and quick-disconnect plugs • Industry standard M12 right angle femaleplug with open leads • These cables can be used with patch cables. • 2m, 5m and 10m cable lengths • PUR (polyurethane) jacket for oily and direct sunlight applications • IP67 /IP68 / IP69K, II rated • LED indication for 10-36 VDC PNP sensors only M12 Quick-Disconnect Cables with LED Indicator (Euro, Micro DC-Single Key) Part Number Price Length Poles Connector white wire Pin 2 black wire Pin 4 LED Jacket Dimensions M12 Quick-Disconnects EVC178* $11.00 2m (6.5 ft) 4 Right-angle female Yes PUR Figure 12 EVC179* $11.50 5m (16.4 ft) 4 Right-angle female Yes PUR Figure 12 EVC180* $14.00 10m (32.8 ft) 4 Right-angle female Yes PUR Figure 12 LED Models’ Wiring *Note: LED for 10 to 36 VDC PNP devices only. Do not use with NPN or analog ouput devices. Do not use when white wire (Pin 2) is used for selection of a sensor function. Do not use when emitter has check function. Book 3 (14.3) eWD-70 Sensor Cables and Connectors 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of June 29, 2016. Check Web site for most current prices. Sensor Cables and Connectors Cable Specifications Specification Length Nominal Voltage M8 2m (6.5 ft) / 7m (23 ft) 5m (16.4 ft) 50 VAC/75 VDC 60 VAC/VDC Max Current 2m (6.5 ft) / 7m (23 ft) 4A 3/4 pin: 250 VAC/VDC, 4A 5 pin: 125 VAC/VDC, 4A 8 pin: 30 VAC/VDC, 2A 12 pin: 30 VAC/VDC, 1.5A N/A IP67 IP65 / IP68 / IP69K Temperature Range Drag Chain (Roller Cable Tray) Suitability Environmental Function Display Power LED Switching Status LED Nickel plated Zinc Gold plated Copper-Tin Alloy (CuSn) Gold plated brass 0.5 Nm  0.4 Nm 0.5 Nm  0.4 Nm 0.6 Nm 0.25 mm2 0.25 mm2 0.25 mm2 0.34 mm2 4 x 0.34 mm2 (4 x 22 AWG) 5 x 0.34 mm2 (5 x 22 AWG) 8 x 0.25 mm2 (8 x 24 AWG) 12 x 0.14 mm2 (12 x 26 AWG) 5mm PVC: 4mm PUR: 4mm 5mm PVC: 4.2 mm PUR: 4.3 mm PVC: 5 - 5.2 mm PUR: 6.0 mm -25° to +80°C (-13° to 176°F) -25° to 90°C (-13° to 194°F) N/A Halogen/Silicone free (24 AWG) (24 AWG) (24 AWG) (22 AWG) PVC: -30° to 70°C -25° to +80°C (-22° to 158°F) (-13° to 176°F) PUR: -50° to 90°C (-58° to 194°F) N/A Halogen/Silicone free PVC: -25° to +70°C (-13° to 158°F) PUR: -25° to +85°C (-13° to 185°F) N/A N/A N/A Bending Radius min. 10 x cable diameter Bending Cycles N/A Travel Speed N/A Torsional Strain N/A Agency Approvals IP67 Polyurethane (PUR) or Polyvinyl-chloride (PVC) Contacts Material Ø Outer Cable PVC: IP68 PUR: IP68 / IP69K IP67 Nickel plated brass Housing Material Conductors Cross Section (AWG) 3m (9.8 ft) / 5m (16.4 ft) / 10m (32.8 ft) / 15m (49.2 ft) 30 VAC/VDC; 125 VAC/VDC; 250 VAC/VDC 4A Material Nut Tightening Torque 5m (16.4 ft) 250 VAC/VDC LED Current Loading Protection Degree M12 7000 Series (unshielded) CD Series RoHS RoHS (UL E325311 8/12 pole) Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s Sensor Cables and Connectors eWD-71 Prices as of June 29, 2016. Check Web site for most current prices. Sensor Cables and Connectors Cable Specifications M12 7000 Series (shielded) M12 with LED Length 5m (16.4 ft) / 10m (32.8 ft) 2m (6.5 ft) / 5m (16.4 ft) / 10m (32.8 ft) Nominal Voltage 30 VAC/VDC / 60 VAC/VDC 10 to 36 VDC Specification Max Current 2A / 4A 4A LED Current Loading N/A 10 V input Brown wire LED: 1.7 mA White and/or Black LED: 0.9 mA 36V input Brown wire LED: 7.3 mA White and/or Black LED: 4.7 mA Protection Degree IP67 IP67 / IP68 / IP69K Nickel plated Zinc Nickel plated Brass Material Nut Jacket Material Polyurethane (PUR) Housing Material Contacts Material Tightening Torque Polyurethane (PUR) Gold plated Brass 0.6 Nm 0.6 to 1.5 Nm 4 x 0.34 mm2 (4 x 22 AWG) 5 x 0.34 mm2 (5 x 22 AWG) 8 x 0.25 mm2 (8 x 24 AWG) 4 x 0.34 mm2 Ø Outer Cable 4/5 pole: 5.9 mm 8 pole: 7mm 5mm Temperature Range -25° to +80°C (-13° to 176°F) -25° to +90°C (-13° to 194°F) Function Display Power LED N/A Green Switching Status LED Bending Radius Bending Cycles N/A Drag Chain (Roller Cable Tray) Suitability Conductors Cross Section (AWG) Travel Speed Torsional Strain Agency Approvals (4 x 22 AWG) 2 x Yellow min. 10 x cable diameter N/A N/A >5 million Max. 3.3 m/s for a horizontal travel length of 5 meters and max. acceleration of 5 m/s2 N/A ±180°/m RoHS UL File E191684, RoHS UL Reference Part Number Mini-Series Female Cord Connectors Series M12, UL Catalog Number ADOAH043MSS0002H04 EVC178 ADOAH043MSS0005H04 EVC179 ADOAH043MSS0010H04 EVC180 Note: Shown in UL file under Mini-series Female Cord Connectors using catalog number Book 3 (14.3) eWD-72 Sensor Cables and Connectors 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of June 29, 2016. Check Web site for most current prices. Sensor Cables and Connectors Dimensions mm [inches] Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 7 Figure 6 Figure 8 Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s Sensor Cables and Connectors eWD-73 Prices as of June 29, 2016. Check Web site for most current prices. Sensor Cables and Connectors Dimensions mm [inches] Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figure 15 Figure 16 Book 3 (14.3) eWD-74 Sensor Cables and Connectors 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of June 29, 2016. Check Web site for most current prices. Sensor Cables and Connectors Dimensions mm [inches] Figure 17 Figure 18 Figure 19 Figure 20 Figure 21 Figure 22 Figure 23 Figure 24 Figure 25 Figure 26 Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s Sensor Cables and Connectors eWD-75 Prices as of June 29, 2016. Check Web site for most current prices. Sensor Cables and Connectors Patch cables with quick-disconnect plugs on each end Available patch cables include: • Industry standard M8 and M12 screw-lock connectors • One male and one female connector • Axial and right-angle connector models • 1m and 3m cable lengths • PVC (polyvinyl chloride)jacket for typical industrial applications • IP67 rated M8 Patch Cables with Quick-Disconnect on Each End (Pico, Nano) Part Number Price Length M8 Quick-Disconnect Patch Cables Poles Connectors Jacket Dimensions 2 Axial - One male and one female connector 2 Right-angle - One male and one female connector 2 Axial - One male and one female connector 2 Right-angle - One male and one female connector PVC Figure 1 PVC Figure 3 PVC Figure 2 PVC Figure 3 CDP08-0A-010-AA $8.25 1m (3.28 ft) 3 CDP08-0A-010-BB $8.25 1m (3.28 ft) 3 CDP08-0A-030-AA $10.00 3m (9.84 ft) 3 CDP08-0A-030-BB $8.25 3 3m (9.84 ft) M12 Patch Cables with Quick-Disconnect on Each End (Euro, Micro DC-Single Key) Part Number Price Length M12 Quick-Disconnect Patch Cables Poles CDP12-0B-010-AA $8.25 1m (3.28 ft.) 4 CDP12-0B-010-BB $8.25 1m (3.28 ft.) 4 CDP12-0B-030-AA $8.25 3m (9.84 ft.) 4 CDP12-0B-030-BB $10.00 3m (9.84 ft.) 4 7000-40041-2150100 $12.00 1m (3.28 ft.) 5 7000-40041-2150300 $15.00 3m (9.84 ft.) 5 Connectors 2 Axial - One male and one female connector 2 Right-angle - One male and one female connector 2 Axial - One male and one female connector 2 Right-angle - One male and one female connector 2 Axial - One male and one female connector 2 Axial - One male and one female connector Jacket Dimensions PVC Figure 4 PVC Figure 5 PVC Figure 4 PVC Figure 5 PVC Figure 7 PVC Figure 7 Patch Cables with LED Available patch cables with LED include: • Right-angle M12 female plug with LED indication on one end and axial male plug on the other end • 0.3m, 0.6m, 1m, 2m, 5m, and 10m cable lengths white wire Pin 2 • PUR (polyurethane) jacket for oily and direct sunlight applications • IP67 /IP68 / IP69K, II rated • LED indication for 10 -36 VDC PNP sensors only M12 Patch Cables with LED Indicator (Euro, Micro DC-Single Key) Part Number Price Length M12 Patch Cables black wire Pin 4 LED Models’ Wiring Poles Connectors LED Jacket Dimensions EVC322* $11.00 0.3m (0.98 ft) 4 Right-angle female, axial male Yes PUR Figure 6 EVC323* $12.00 0.6m (1.97 ft) 4 Right-angle female, axial male Yes PUR Figure 6 EVC324* $12.50 1m (3.28 ft) 4 Right-angle female, axial male Yes PUR Figure 6 EVC325* $14.50 2m (6.5 ft) 4 Right-angle female, axial male Yes PUR Figure 6 EVC326* $17.00 5m (16.4 ft) 4 Right-angle female, axial male Yes PUR Figure 6 EVC327* $21.50 10m (32.8 ft) 4 Right-angle female, axial male Yes PUR Figure 6 *Note: LED for 10 to 36 VDC PNP devices only. Do not use with NPN or analog ouput devices. Do not use when white wire (Pin 2) is used for selection of a sensor function. Do not use when emitter has check function. Book 3 (14.3) eWD-76 Sensor Cables and Connectors 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of June 29, 2016. Check Web site for most current prices. Sensor Cables and Connectors Cable Specifications Specification Length M8 M12 1m (3.28 ft.) / 3m (9.84 ft.) Nominal Voltage 4A LED Current Consumption N/A Material Nut Jacket Material Housing Material Contacts Material Conductors Cross Section (AWG) Tightening Torque Drag Chain (Roller Cable Tray) Suitability Ø Outer Cable Temperature Range Function Display LED Switching Status LED 0.3m (0.98 ft) / 0.6m (1.97 ft) / 1m (3.28 ft) 2m (6.5 ft) / 5m (16.4 ft) / 10m (32.8 ft) 125 VAC/VDC 250 VAC/VDC 60 VAC/VDC Max Current Protection Degree M12 with LED 10 to 36 VDC 4A 10V input Brown wire LED: 1.7 mA White and/or Black LED: 0.9 mA 36V input Brown wire LED: 7.3 mA White and/or Black LED: 4.7 mA IEC IP67 Zinc pressure die casting surface Nickel plated brass (Ni4-6), Nickel plated brass PolyVinyl Chloride (PVC) IEC IP67/IP68/IP69K Polyurethane (PUR) Connector: Orange PUR, Socket: Black PUR Nickel plated brass Polyurethane (PUR) Copper-tin(CuSn) plated brass Gold plated brass 0.34 mm² 0.34 mm² (22 AWG) Plug: 0.6 to 1.5 Nm (take into account the maximum value of the counterpart) Socket: 0.6 to 1.5 Nm 5mm 0.5 Nm 0.6 Nm, 0.5 Nm 5mm 5.2 mm, 5mm -25° to +70°C (-13° to 158°F) -25° to +90°C (-13° to 194°F) N/A Green N/A 2 x Yellow Bending Radius min. 10 x cable diameter Bending Cycles >5 million Travel Speed Torsional Strain Agency Approvals N/A Max. 3.3 m/s for a horizontal travel length of 5 m and max. acceleration of 5 m/s² N/A ±180°/m RoHS UL File E191684, RoHS UL Reference Part Number EVC322 EVC323 EVC324 EVC325 EVC326 EVC327 Cable Assemblies Series M12, UL Catalog Number VDOAH043MSS00.3H04STGH040MSS VDOAH043MSS00.6H04STGH040MSS VDOAH043MSS0001H04STGH040MSS VDOAH043MSS0002H04STGH040MSS VDOAH043MSS0005H04STGH040MSS VDOAH043MSS0010H04STGH040MSS Note: Shown in UL file under Cable Assemblies using catalog number Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s Sensor Cables and Connectors eWD-77 Prices as of June 29, 2016. Check Web site for most current prices. Sensor Cables and Connectors Dimensions Figure 1 mm [inches] Figure 2 Figure 4 Figure 3 Figure 6 Figure 5 Figure 7 Book 3 (14.3) eWD-78 Sensor Cables and Connectors 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of June 29, 2016. Check Web site for most current prices. IP69K-rated M12 Sensor Cables Cable Specifications Specification Length M12 1/2” 0.3m (0.98 ft), 0.6m (1.97 ft), 1m (3.3 ft), 2m (6.6 ft), 5m (16.4 ft), 10m (32.8 ft) 5m (16.4 ft), 10m (32.8 ft) 250 VAC/300 VDC 300 VAC/VDC 4A 4A IEC IP67 / IP68 / IP69K IEC IP67 / IP68 / IP69K Nominal Voltage Max Current Protection Degree Material Nut Jacket Material Housing Material Contacts Material Tightening Torque Conductors Cross Section (AWG) Ø Outer Cable Temperature Range Environmental Bending Radius Agency Approvals 316L Stainless steel 316L Stainless steel PolyVinyl Chloride (PVC) PolyVinyl Chloride (PVC) PolyVinyl Chloride (PVC) PolyVinyl Chloride (PVC) Gold plated Gold plated 0.6 to 1.5 Nm 22 AWG 22 AWG 4.9 mm 4.5 mm -25° to 100°C (-13° to 212°F) -10° to 100°C (14° to 212°F) Halogen free, Silicone free Halogen free, Silicone free min. 10 x cable diameter UL E191684 Wiring - M12 DC UL E177636 UL Reference EVT221, EVT222, EVT223, EVT224 Brown White Blue Black EVT225, EVT226, EVT227, EVT228, EVT229, EVT230, EVT231, EVT232, EVT233, EVT234 Wiring - 1/2” Micro AC Part Number UL Catalog Number EVT221 ADOGH040VAS0005E04 EVT222 ADOAH040VAS0005E04 EVT223 ADOGH040VAS0010E04 EVT224 ADOAH040VAS0010E04 EVT225 VDOGH040VAS00.3E04STGH040VAS EVT226 VDOAH040VAS00.3E04STGH040VAS EVT227 VDOGH040VAS00.6E04STGH040VAS EVT228 VDOAH040VAS00.6E04STGH040VAS EVT229 VDOGH040VAS0001E04STGH040VAS EVT230 VDOAH040VAS0001E04STGH040VAS EVT231 VDOGH040VAS0002E04STGH040VAS EVT232 VDOAH040VAS0002E04STGH040VAS EVT233 VDOGH040VAS0005E04STGH040VAS EVT234 VDOAH040VAS0005E04STGH040VAS E18446, E18447, E18448, E18449 Green Red/Black Red/White Book 3 (14.3) eWD-84 Sensor Cables and Connectors 1 - 8 0 0 - 633 - 0 4 0 5 For the latest prices, please check AutomationDirect.com. BX Series High Resolution Area Sensor High resolution area sensor (light screen) - DC • 70 mm controlled area height • Operating distance up to 2m • Adjustable sensitivity • NPN or PNP with NO/NC selectable output • Emitter and receiver LED status indicators • IP67 rated BX80 Series Area Sensor Selection Chart Part Number Price Function Sensing Range Output State BX80B-1N-0H $197.00 Receiver BX80B-1P-0H $197.00 Receiver N.O./N.C. 2m (78.74in) Emitter Connection Wiring NPN PNP Receiver dependent Figure 1 Figure 2 M12 (12mm) connector Receiver dependent Specifications Type Sensing Distance Light Spot Diameter Emission Sensitivity Output Type Operating Voltage No-load Supply Current Operating (Load) Current Off-state (Leakage) Current Voltage Drop Switching Frequency Ripple Time Delay Before Availability (tv) Short-Circuit Protection Operating Temperature Protection Degree (DIN 40050) Emitter’s LED Indicators - Switching Status Dimensions Thru-beam (mm) 2m (2.56 ft) N/A Infrared (880nm) 27 14.7 NPN or PNP; N.O./N.C.selectable 44 20 Fixed 9 1.4 o4.2 7.2 12-24VDC 66 m100mA 110 120 Emitter: 100mA; Receiver: 50mA m10µA 11.5 1.2volt maximum at 100mA 23.5 10 15 5 Ch 24 23 3 16.5 500ms Yes (switch autoresets after overload is removed) 6.5 50Hz m10% 11.5 Ch 13 14 BX80S-10-0H $166.00 selectable Logic -25° to 50°C (-13° to 122°F) Receiver’s LED Indicators - Switching Status Housing Material Lens Material Shock/Vibration Tightening Torque Weight Agency Approvals IEC IP67 Green (power), Red (sync. alarm), Yellow (area occupied) Green (power), Red (alignment alarm), Yellow (output energized) Polybutylene Terephthalate (PBT) Receiver Emitter 25 Nm (18.44 lb-ft) max. _ BU/3 300g (10.58oz) + BN/1 cULus E187310, CE Light on N.C. Dark on N.O. 12-24VDC + SYNC + WH/2 N.O. Connectors BN/1 Receiver Supply (-) Output tPHS-134 Photoelectric Sensors Sync (+) Supply (+) + BN/1 BK/4 Load WH/2 Receiver BU/3 + _ 12-24VDC + BN/1 _ BU/3 Load BK/4 Supply (-) SYNC Supply (+) BU/3 SYNC _ BK/4 Emitter Sync (-) _ Figure 2 N.C. Emitter 1 Figure 1 See terminology section Thru-beam and Diffuse Reflective Reflective Models Models 1 20 16.5 Wiring diagrams Polycarbonate (PC) Switching Element Function 12 1 32 o 1.5 Sync _ BK/4 SYNC + WH/2 _ WH/2 1-800-633-0405 For the latest prices, please check AutomationDirect.com. Reflectors RL series reflectors for polarized reflective photoelectric sensors (all models) • Suitable for use with polarized light photoelectric sensors • Shapes and sizes for most applications • Miniature types for close mounting in multiple sensor installations • Single hole, dual hole and self-adhesive mounting types available • Single and 10-packs available Installation notes • Keep the reflector surface clean to ensure peak detection performance. This is especially true when the maximum sensing range is being used. Clean using a damp cloth. • When selecting a reflector, it is important to consider the ambient conditions it will be exposed to. Dusty or high humidity conditions may reduce the sensing range as much as 90%. • Reflectors should be positioned at a 90° angle to the optical axis with a tolerance of ±15°. Specifications Model Price RL102 Quantity Dimensions $35.00 10 per pack RL102-1 $3.75 1 per pack RL103 $40.00 10 per pack RL103-1 $4.25 1 per pack RL104 $40.00 10 per pack RL104-1 $4.25 1 per pack RL105 $35.00 10 per pack RL105-1 $3.75 1 per pack RL106G $40.00 10 per pack RL106G-1 $4.25 1 per pack RL110 $18.00 10 per pack RL110-1 $2.00 1 per pack RL116 $18.00 10 per pack RL116-1 $2.00 1 per pack RL100DA4 $32.50 1 per pack RL100DC4 $10.00 1 per pack RL100DQ1 $7.50 1 per pack RL111G $52.00 10 per pack RL111G-1 $6.00 1 per pack RL112G $40.00 10 per pack RL112G-1 $4.25 1 per pack 19 x 73mm [0.75 x 2.87 in] RL113G $46.00 10 per pack 51.4 x 60.3mm [2.02 x 2.37 in] RL113G-1 $5.00 1 per pack Degree of Protection Mounting Materials Ø25mm [0.98 in] Customer-supplied adhesive or other mounting method required Ø34.5mm [1.36 in] Ø46mm [Ø1.81 in] 90 x 40mm [3.54 x 1.58 in] two Ø4.3 mm holes 182 x 42mm [7.17 x 1.65 in] two Ø6 mm holes Ø84mm [3.31 in] Reflective face: PMMA Polymethylmethacrylate (acrylic); base material: ABS (Acrylonitrile-butadiene-styren) one Ø5 mm hole IEC IP67 41 x 60mm [3.54 x 2.36 in] two M3 holes 200 x 300mm [7.87 x 11.81 in] 50 x 300mm [1.97 x 11.81 in] 100 x 100mm [3.94 x 3.94 in] Self-adhesive Paper (Acrylic tape with micro prism) 22.5 x 47mm [0.89 x 21.85 in] two M3 slots Reflective face: PMMA Polymethylmethacrylate (acrylic); base material: ABS (Acrylonitrile-butadiene-styren) two M4 slots Not recommended for applications involving moist air environments or water immersion. www.automationdirect.com/photoelectric Photoelectric Sensors tPHS-135 For the latest prices, please check AutomationDirect.com. Reflectors RL series reflectors for polarized reflective laser photoelectric sensors (FALN series) • Suitable for use with polarized light laser photoelectric sensors • Sizes for most applications • Miniature types for close mounting in multiple sensor installations • Single and 5-packs available Dimensions Specifications Model RL201 RL201-1 RL203 RL203-1 RL204 RL204-1 Price $32.00 $7.00 $30.00 $6.50 $26.00 $5.75 Quantity (per package) 5 1 5 1 5 1 Dimensions 60mm x 82mm 2.36 in x 3.23 in Degree of Protection Mounting 1 two Ø 0.4 mm holes Materials 19mm x 60mm 0.75 in x 2.36 in IEC IP67 20mm x 32mm 0.80 in x 1.26 in two Ø 0.4 mm holes two Ø 0.3 mm holes Acrylic/polycarbonate 1 Not recommended for applications involving moist air environments or water immersion. mm [inches] RL102/RL102-1 RL103/RL103-1 RL104/RL104-1 RL105/RL105-1 RL106G/RL106G-1 tPHS-136 Photoelectric Sensors 1-800-633-0405 For the latest prices, please check AutomationDirect.com. Reflectors Dimensions mm [inches] RL110/RL110-1 RL111G/RL111G-1 RL112G/RL112G-1 RL113G/RL113G-1 RL116/RL116-1 RL201/RL201-1 RL203/RL203-1 RL204/RL204-1 www.automationdirect.com/photoelectric Photoelectric Sensors tPHS-137 For the latest prices, please check AutomationDirect.com. Shutters and Adapters ST0S1 through ST0S8 shutters for M18 (18 mm) through-beam sensors (SSE / SSR) •  Reduces the emitted beam, allowing the detection of small targets •  Shutter consists of an aluminum cap and aperture with an o-ring and glass lens, which can screw onto the optical head of either the emitter or receiver Sensing Distance (when used with SSE / SSR Model photoelectric switches) Model ST0S1 ST0S2 ST0S4 ST0S6 ST0S8 Price $13.50 $13.50 $13.50 $13.50 $13.50 1 2 4 6 8 N/A N/A N/A N/A 1.5 2 3.5 3 6.5 4 Ø x shutter (mm) Distance (m) object (mm) Table shows sensing distance and minimal detectable object. ST03 right-angle M18 (18 mm) beam adapter Beam Adapters Part Number Price ST03 tPHS-138 Description For use with M18 retroreflective and through-beam photoelectric switches (not for use with diffuse reflection $13.50 sensors). Allows 90° light detection using an internal mirror set at 45° to the optical axis. Sensitivity loss is about 20-30%. Photoelectric Sensors 1-800-633-0405 For the latest prices, please check AutomationDirect.com. Accessories: Mounting Brackets ST12A axial bracket For mounting M12 (12mm) sensors. Has two mounting holes (use 3mm screws) and allows the rotation of an optical axis for right-beam angle adapter sensors. Brackets ST12C right-angle bracket Angular mounting bracket for use with M12 (12mm) sensors. Has two mounting holes (use 3mm screws) and allows the rotation of an optical axis for axial sensors. Brackets Part Number Price Description $2.00 Metal axial bracket for 12mm sensors, 1/pk ST12A $6.00 316L stainless steel axial bracket for 12mm sensors, 1/pk ST12A7W Part Number Price Description $6.00 Metal right angle bracket for 12mm sensors, 1/pk ST12C $6.00 316L stainless steel right angle bracket for 12mm sensors, 1/pk ST12C7W ST18A axial bracket ST18C right-angle bracket Mounting bracket for M18 (18mm) sensors. Has two mounting holes (use 4mm screws) and allows the rotation of an optical axis for right-beam angle adapter sensors. Angular mounting bracket for M18 (18mm) sensors. Has two mounting holes (use 4mm screws) and allows the rotation of an optical axis for axial sensors. Brackets Part Number Price Description $1.25 Metal axial bracket for 18mm sensors, 1/pk ST18A $6.00 316L stainless steel axial bracket for 18mm sensors, 1/pk ST18A7W Brackets Part Number Price Description $1.25 Metal right angle bracket for 18mm sensors, 1/pk ST18C $6.00 316L stainless steel right angle bracket for 18mm sensors, 1/pk ST18C7W www.automationdirect.com/photoelectric Photoelectric Sensors tPHS-139 For the latest prices, please check AutomationDirect.com. Accessories: Mounting Brackets ST02 plastic swivel bracket M18 (18 mm) Brackets Part Number Price Description ST02 $8.25 Plastic mounting bracket for use with M18 photoelectric switches. Has a ball-joint and set screws to adjust sensor orientation. Allows orientation in all directions for retroreflective and through-beam sensors. (Will not work with C18 series). Dimensions inches [mm] tPHS-140 Photoelectric Sensors 1-800-633-0405 For the latest prices, please check AutomationDirect.com. Accessories: Mounting Brackets ST-S8 and ST-5072 mounting brackets Contrast Sensor Brackets Part Description Number Price ST-S8-FRM $8.00 Datalogic mounting bracket, 304 stainless steel, vertical. For use with S8 series contrast sensors. ST-5072 mounting bracket, 304 stainless steel, right-angle. For use with S8 series contrast $10.00 Datalogic sensors. Weight [lb] 0.48 0.10 Dimensions mm [inches] ST-S8-FRM ST-5072 See our website: www.AutomationDirect.com for complete Engineering drawings. tPHS-142 Photoelectric Sensors 1-800-633-0405