Specifications For Fans With Alarms (pg. F-21 To F-24)

   EMBED


Share

Transcript

Cooling Fans Introduction Specifications for Fans with Alarms AC Input Variable Flow MRS ■ Stall Alarm, Electronic Alarm Type MRS The alarm specifications vary depending on the type of alarm and fan. Check the alarm specifications according to the alarm and fan type you use. Specifications can also be referred to by the alarm specifications number shown on the specifications for each product. Axial Flow Fans An alarm is output when the fan stops while operating. Alarm Activation Speed Output Mode Output Condition Maximum Rating Delay Function ● Example of Alarm Circuit Connection When locked Open-collector output Operation: L level (Internal transistor ON) When locked: H level (Internal transistor OFF) Maximum applied voltage: 30 VDC max. Maximum current: 5 mA max. Not built-in: External delay circuit is required to prevent alarm detection when starting the fan. The delay time should be at least 1 second. 5 mA Yellow or Orange max. 30 VDC max. R Black GND Fan 0V Controller DC Input Long-Life MDE ● Alarm Specifications MDS/MD ① ● Models ◇MDS/MD Series: MDS1451-□LH, MDS1451-□L, MD925A-□LH, MD925A-□L, MD825B-□LH, MD825B-□L, MD625B-□LH, MD625B-□L, MDS510-□LH, MDS510-□L, MDS410-□LH, MDS410-□L ◇MDE Series: MDE1451-□L2, MDE1225-□L MU Alarm Specifications Number MB Alarm Specifications Number ● Models ◇MRS Series: MRS25-□M, MRS20-□M, MRS18-□MH, MRS18-□TM, MRS16-□TM ● Example of Alarm Circuit Connection ● Alarm Specifications Maximum Rating Fan 30 VDC max. R 0V Controller Black or Blue MFD Delay Function 15 mA max. Orange MF Output Condition 1800±300 r/min Open-collector output Normal operation: L level (Internal transistor ON) Alarm output: H level (Internal transistor OFF) Maximum applied voltage: 30 VDC max. Maximum current: 15 mA max. Not built-in: External delay circuit is required to prevent alarm detection when starting the fan. The delay time should be at least 10 seconds. FM ● Models ◇MRS Series: MRS14-TTM Power Supply for Driving Alarm Circuit 5 VDC±5% Delay Function Built-in starting delay time: 25 sec. max. (The alarm function starts monitoring within 25 seconds after the power is turned on.) Black 0V Controller Fan ● Example of Alarm Circuit Connection ● Alarm Specifications Output Condition Maximum Rating Delay Function CAD Data Manuals 15 mA 30 VDC max. max. R ● Models ◇MDS Series: MDS1225-□MH, MDS1225-□M Alarm Activation Speed Output Mode ④ Orange Installation Alarm Specifications Number Maximum Rating Red 5 VDC Accessories Output Condition 1800±300 r/min Open-collector output Normal operation: L level (Internal transistor ON) Alarm output: H level (Internal transistor OFF) Maximum applied voltage: 30 VDC max. Maximum current: 15 mA max. Thermostats Alarm Activation Speed Output Mode ③ ● Example of Alarm Circuit Connection ● Alarm Specifications Cooling Module Alarm Specifications Number Cross Flow Fans AC Input DC Input Alarm Activation Speed Output Mode ② MBD An alarm is output when the fan speed drops to a specific level. Output mode is electronic output. Centrifugal Blowers AC Input DC Input ■ Low-Speed Alarm, Electronic Alarm Type 2100±400 r/min Open-collector output Normal operation: L level (Internal transistor ON) Alarm output: H level (Internal transistor OFF) Maximum applied voltage: 30 VDC max. Maximum current: 15 mA max. Built-in starting delay time: 10 sec. max. (The alarm function starts monitoring within 10 seconds after the power is turned on.) www.orientalmotor.com Technical Support TEL: (800) 468-3982 E-mail: [email protected] 15 mA Orange max. 30 VDC max. R Blue GND Fan 0V Controller F-21 Introduction ■ Low-Speed Alarm, Contact Alarm Type An alarm is output when the fan speed drops to a specific level. Output mode is contact output. Alarm Specifications Number ● Models ◇MRS Series: MRS25-□B ● Alarm Specifications Alarm Activation Speed Output Mode Output Condition ⑤ Alarm Specifications Number Maximum Rating Delay Function ● Alarm Specifications Output Condition Alarm Specifications Number Maximum Rating Delay Function Output Condition Maximum Rating Delay Function 0V Controller Fan 1800±300 r/min Relay output Normal operation: Contact OFF Alarm output: Contact ON Contact capacity Resistive load: max.10 VA (max. 100 V/max. 0.5 A) Not built-in: External delay circuit is required to prevent alarm detection when starting the fan. The delay time should be at least 10 seconds. ● Example of Alarm Circuit Connection R White Black 0V Controller Fan MBD10-24A, MBD8-24A: 1500±400 r/min MBD12-24A: 1300±400 r/min Relay output Normal operation: Contact ON Alarm output: Contact OFF Maximum applied voltage: 30 VDC max. Maximum current: 30 mA max. Built-in starting delay time: 10 sec. max. (The alarm function starts monitoring within 10 seconds after the power is turned on.) ● Example of Alarm Circuit Connection White 30 mA max. 30 VDC max. R Blue 0V Controller Fan ● Models ◇MDS Series: MDS1751-24BH, MDS1751-24B ● Alarm Specifications Alarm Activation Speed Output Mode Output Condition Maximum Rating ⑧ Black ● Alarm Specifications Output Mode Alarm Specifications Number R White ● Models ◇MBD Series: MBD12-24A, MBD10-24A, MBD8-24A Alarm Activation Speed ⑦ ● Example of Alarm Circuit Connection ● Models ◇MRS Series: MRS16-□TA Alarm Activation Speed Output Mode ⑥ 1800±300 r/min Relay output Normal operation: Contact ON Alarm output: Contact OFF Contact capacity Resistive load: max.10 VA (max. 100 V/max. 0.5 A) Not built-in: External delay circuit is required to prevent alarm detection when starting the fan. The delay time should be at least 10 seconds. Delay Function 1800±400 r/min Relay output Normal operation: Contact ON Alarm output: Contact OFF Maximum applied voltage: 30 VDC max. Maximum current: 30 mA max. Built-in starting delay time: 10 sec. max. (The alarm function starts monitoring within 10 seconds after the power is turned on.) ● Example of Alarm Circuit Connection ◇MDS1751-24BH 30 mA Orange max. 30 VDC max. R Blue 0V Controller Fan ◇MDS1751-24B White 30 mA max. 30 VDC max. R Blue Fan F-22 ORIENTAL MOTOR GENERAL CATALOG 2012/2013 0V Controller Cooling Fans Introduction ■ Pulse Sensor Type Two pulses are output per revolution of the fan. Fan speed is monitored as the host controller, etc., reads the output pulses. This function helps you set a desired output speed for alarm activation. ● Models ◇MDS/MD Series: MDS1751-24SH, MDS1751-24S, MD925A-□SH, MD925A-□S, MD825B-□SH, MD825B-□S, MD625B-□SH, MD625B-□S ◇MBD Series: MBD10-□S, MBD8-□S Output Pulse Output Mode Two pulses per fan revolution Open-collector output ● Normal ● When Operation GND Fan 0V T4 0V Controller T=T1+T2+T3+T4 One fan revolution 60 T [s] N: Speed [r/min] = T1∼T4 = 4N 4 T1 Pulse width duty = = 50±10% T1+T2 Maximum applied voltage: 30 VDC max. Maximum current Ic: MD925A-□SH, MD925A-□S, MD825B-□SH, MD825B-□S, MD625B-□SH, MD625B-□S: 5 mA max. MDS1751-24SH, MDS1751-24S, MBD Series: 10 mA max. MB ● Alarm Specifications ● Example of Alarm Circuit Connection ● Normal ● When Operation VOH VOL 0V VOL 0V T2 T3 T4 T=T1+T2+T3+T4 One fan revolution Black 0.6 s 5s Fan GND 0V Controller or VOH 0V Maximum applied voltage: 30 VDC max. Maximum current: 5 mA max. MFD 60 T [s] N: Speed [r/min] = T1 ∼T4 = 4N 4 T1 Pulse width duty = = 50±10% T1+T2 Maximum Rating 30 VDC max. R MF Output Condition T1 Locked 5 mA max. Cross Flow Fans AC Input DC Input VOH Yellow MBD Two pulses per fan revolution Open-collector output Centrifugal Blowers AC Input DC Input ● Models ◇MDS Series: MDS1451-□SH, MDS1451-□S Output Pulse Output Mode ⑩ T3 DC Input Long-Life MDE Alarm Specifications Number Black MDS/MD Maximum Rating T2 30 VDC max. R Axial Flow Fans Output Condition T1 Ic MU ⑨ Locked VOH VOH VOL 0V Yellow AC Input Variable Flow MRS ● Example of Alarm Circuit Connection ● Alarm Specifications MRS Alarm Specifications Number FM Cooling Module Thermostats Accessories Installation CAD Data Manuals www.orientalmotor.com Technical Support TEL: (800) 468-3982 E-mail: [email protected] F-23