Preview only show first 10 pages with watermark. For full document please download

Specifications For Quickscan™ Bladder Ultrasound Measurements

   EMBED


Share

Transcript

Specifications for QuickScan™ Bladder Ultrasound Measurements: Calculated: Bladder Volume/Post Void Residual Non-calculated: Distance Free-hand Area 5 Point Area Circle Patient Types: Adults: 3.5 MHz Pediatrics: 5.0 MHz Key Features: PC: Touch Screen Tablet Onboard Video Tutorial:Yes Power: Powered by USB port of Tablet Cine:Stores 32 to 512 sequential images Patient Data Storage: > 500 Patient Records Range: Bladder Volume: 0-1800 cc Accuracy: Bladder Volume: ±10%, ±10 cc Distance: ±5%, ±5 mm Ultrasound Probe Dimensions and Weight: Width: 4.5 cm (1.8 in) Height: 4.5 cm (1.8 in) Length: 17 cm (6.7 in) Weight: 200 grams (7 oz) Ultrasound Output Parameters: Depth Range: 10, 15 and 20 cm (Selectable) Pulse Frequency: 3.5 MHz and 5.0 MHz (Selectable) Focal Zone: 4 cm - 15 cm Focal Point: 7.5 cm at 3.5 MHz, 6 cm at 5.0 MHz Scan Angle: 90° Scan Mode: B-Mode Patient Contact: 35 mm (1.38 in) Frame Rate: 12 fps - 15 fps ISPTA: 94 mW/cm² (Maximum) ISPPA Range: 0 - 68 mW/cm² Mechanical Index: 1.9 (Maximum) Transducer Diameter: 17 mm (0.67 in) Transducer Resonant Frequency: 3.5 MHz Transducer Bandwidth: Over 60% Number of Scanning Planes: 1 to 2 Pulse Repetition Frequency: 30 MHz TIS: 0.610 Tablet: Display: 10.8 in Touch Screen Resolution: 1920 X 1080 Processor: Up to 2.4 GHz Quad Core RAM: 2 GB Hard Drive: 64 GB Battery: 32 Whr Rechargeable Battery providing 8-10 hours of use Thickness: 10.2 mm (0.4 in) Width: 176.8 mm (6.96 in) Length: 297.7 mm (11.72 in) Weight: 771.5 g (1.57 lbs) Operating Conditions: Ambient Temperature: 10°C to 35°C (50°F to 95°F) Relative Humidity: 20% to 80% no condensing Atmospheric Pressure: 700 hPa to 1060 hPa Cleaning: Ultrasound probes are very durable. Reasonable care must be taken to avoid damaging them. Handle the membrane on the tip of the probe and the cable attachment at the other end of the probe with care. Keep the probe membrane away from sharp objects to avoid damage. To clean the probe between uses, wipe with a soft non-abrasive cloth using any standard disinfecting cleaning agent that you use in your practice. In the case of sterile procedures, a sterile drape and sterile gel should be used. Storage/Transportation Conditions: Ambient Temperature: -10°C to 50°C (14°F to 122°F) Relative Humidity: 20% to 80% no condensing Atmospheric Pressure: 700 hPa to 1060 hPa Warranty: Ultrasound Probe: 1 Year Parts and Labor PC: 1 Year Parts and Labor Standards and Approvals: ISO 13485:2003